Document RRm75n17L1RM00Q8o3EOabvk
To:
Mike Breckenridge
cc: Mackie Comeaux R.J. Grahek G. Higby L. Larson M.M. Marshall E.c. Martinelli/W.F. C. Mattia J. Kovac
Patient
From: Dan Gleghorn
December 10, 1992
/. iV
PLAQUEMINE 1992
INDUSTRIAL HEALTH AUDIT
Enclosed is the final report of the Geon Vinyl Division Industrial Health Audit conducted in your facility by Herm Waltemate and me during the period of December 1 through 4, 1992.
X would like to thank you for the hospitality afforded us during our visit to your facility.
Mackie Comeaux's assistance helped me complete the audit in a timely manner. I also appreciate the help provided by you and others at the facility even though you are very busy.
You are fortunate to have Mackie Comeaux who has been working diligently to reformulate and implement your industrial health strategy in addition to all his other duties.
During the audit, we pointed out conditions that violated BFGoodrich or OSHA standards or were inconsistent with good health practices.
The facility was rated with
72 "Satisfactory", 25 "Needs
Attention" and 65 "Does Not Apply" items.
Items to be corrected were developed from the Audit Checklist and
the Inspection Tour notes.
These documents can serve as a
reference as you develop your abatement plan. The report formate
is laid out for you to write in your abatement program and indicate
the status as complete, in-progress or no action. A progress
report giving the status of the items requiring attention is due
in 60 days and on a quarterly basis thereafter until completion of
all items. All items are to be resolved within a one (1) year time
frame.
A computer disk in Word Perfect format is included for your use in complying with this request.
NGC 12944
The report includes the following:
I IX III IV
Favorable Observations Items from Previous Audit Items to Be Corrected Industrial Health Program Rating
__________
Dan Gleghorn
deg 12/03/92 AUDITPLA
NGC 12945
PLAQUEMINE INDUSTRIAL HEALTH AUDIT
December 1 & 4, 1992
I Favorable Observations
1. As mentioned before, you are fortunate to have Mackie Comeaux to redefine and implement your industrial Health Strategy. It is obvious that your facility supports the strategy.
2. Although you do not have a nurse your Medical Surveillance program is administered well by Mackie. Your relationship with Dr. Grace and Barbie Landry of the Grace Clinic appears to be working well.
3. The training programs are very good.
4. Mackie and the VCM Task Force is to be commended for the fine work they did in reducing worker exposures to VCM in the Resin Area. This program was carried forward even though the Resin Area was to be shut down.
II. Items from 1990 IH Audit
IH--1990--2
Raw Materials are not all labeled with hazard information. This is a divisional problem which is being handled now. You will be advised of actions required by your facility. This item has been designated as IH-1992--2.
Ill. 1992 Items To Be Corrected
IH-1992-1
For Information Only: Product specific MSDS were not available for each compound produced by the plant. This is an issue that is being corrected on a divisional level. As you receive Product MSDS you should continue to add them to the MSDS books in addition to updating the book's index.
deg 12/10/92 auditpla.92f/3
NGC 12946
IH--1992--2
OSHA 29 CFR 1910.1200 (f) (5), Hazard Communication, requires that each container of Hazardous Material be Labeled. The following items must be corrected:
1. Bags of raw material including: a. Glycolube 825 FG (the pallet was labeled but not the individual bags) b. Witco Sunlite 160 (BFG Code 160) c. Emersol 132 NF (BFG Code L-2 & L-22) d. Rhodiastab 50 e. Hoechst Wax E
By copy of the is report 1 am asking John Kovac to contact the suppliers of the above unlabeled material to assure future shipments are properly labeled.
2. Three Fiber Drums of Powder Compound, from Deer Park, in the Warehouse are not labeled. They are marked 87717-W-1001.
These are issues that must be corrected on a divisional level. You will be advised of the necessary response require of the plant.
3. A Bulk storage box, intended for storing compound, was found in the Compound Warehouse labeled Zinc Stearate. The box retains the Compound Labels. These labels do not indicate the true contents of the container and must be deleted.
4. Containers and partial bags of raw materials must be labeled.
John Kovac is requested to advise correction of Item l. and the plant is requested to advise correction of this item 2, 3 and 4.
Response
deg 12/10/92 auditpla.92 f/4
Status Complete In-progress No Action
NOC 12947
IH-1992-3
The monitoring program to support your monitoring priority strategy is progressing. Cadmium, Chromium, Dust, Lead, Noise (dosimetry) and Tin exposures found in your monitoring priority strategy need to be monitored. Please advise me of your time table to do this monitoring and when it has been completed.
Response
Status
_____ Complete _____ In-progress _____ No Action
deg 12/10/92 auditpla.92f/5
NGC 12948
IH-1992-4
IH--101 "Ventilation Section" deals with ventilation equipment designed for control of health hazards and requires annual ventilation flow and maintenance checks which are documented. Engineering Standard 11ST--411" gives engineering and design standards for ventilation equipment. This item could be added to your maintenance PM system. Please advise me your method for handling this matter and the time table for initiation.
Response
Status
Complete In-progress No Action
deg 12/10/92 auditpla.92 f/6
ngc 12949
IH--1992--5
Several Industrial Health Written updating to delete references Manufacturing. They include:
1. Respiratory 2. Hazard Communication 3. Chemical Hygiene Plan 4. Lead 5. Vinyl Chloride
Programs require to the Resin
Please indicate your time table to revise these standards.
Response
Status
Complete In-progress No Action
deg 12/10/92 auditpla.92f/7
NGC 12950
IH-1992-6
Most Noise Hazardous Areas are posted but several are not. Your Noise Exposure Survey should be consulted to determine which areas should be posted.
Please advise when posting of the remaining areas is complete.
Response
IH-1992-7
Status
Complete In-progress No Action
Your Noise Audiodosimeters and Sound Level Meter need to be factory calibrated.
Please advise when this item has been completed.
Response
deg 12/10/92 auditpla.92f/8
Status Complete In-progress No Action
NGC 12951
IH--1992-8
Some Breathing Air Stations in Compounding are not marked. An air hoist was observed connected up-stream of the Breathing Air Station at the cooler (CLR-3L). Breathing Air connectors are compatible with other hose connectors.
The Above items must be corrected or you may want to discontinue the use of Breathing Air in the Compound Area.
Please advise the correction of the above or the discontinuance of the use of Breathing Air in the Compound Area.
Response
Status
Complete In-progress No Action
deg 12/10/92 auditpla.92f/9
NGC 12952
IH--1992--9
You must develop and implement a Written Program to comply with IH-204, "Protection of Potable Water Supply".
Please advise when this item has been completed.
Response
Status
Complete In-progress No Action
deg 12/10/92 auditpla.92f/10
NGC 12953
VI.
GEON VINYL DIVISION SPECIALTY POLYMERS & CHEMICALS DIVISION
INDUSTRIAL HEALTH AUDIT CHECKLIST
LOCATION Plaquemine
DATE 12/1 - 4. 92
s = Satisfactory
NA = Needs Attention DNA = Does Not Apply
A. INDUSTRIAL HEALTH PROGRAM ADMINISTRATION
l. Industrial Health Coordinator
a. Named
b. Knowledgeable c. Walk-throughs
S_
S_____ ___S____
2. Periodic industrial Health Program Reports
a. Timely b. Content c. Quarterly Reports
d. Year-end Report e. Goals for Next Year
S S S
S S
3. Medical Services
a. Physical Examination b. Medical Equipment Certification
Calibration c. Professional Training d. illness and Complaint Investigation
S DNA
DNA S
4. Job Exposure Surveys
a. Complete b. New Exposure Review b. Annual Review and Update
_S_ S_
DNA
5. Chemical Hazard Review and Use
a* Committee Established (New Chemical Review) b. MSDS
S
1. Available (Need GVD PVC MSDS's) 2. Employees Trained in Use
NA _S
deg 12/10/92 auditpla.92f/ll
NGC 12954
IH-201A
Revised 09/25/91
.6 Reply to Industrial Health Audits
a. Initial b. Final Report
S S
PEL s and Fetal Toxicity
Written Program
a. Hazard Communication b. Acrylonitrile c. Benzene d. Carbon Tetrachloride e. Chromium VI f. Chloroform g. Dimethyl Acetamide h. Ethylene Thiourea i. Lead j . Mercury (Vapors) k. Methyl Ethyl Ketorve 1. Vinvl Chloride
NA DNA DNA DNA DNA DNA DNA DNA NA DNA DNA NA
Medical
Training
Surveillance
DNA DNA DNA DNA DNA DNA DNA DNA DNA DNA DNA S
s DNA
DNA DNA DNA DNA DNA DNA DNA DNA DNA S
Monitoring for OSHA PEL'S by Area From (month/year)
and Fetal 1/1/91
Number of
Samples
Toxicity (FT) to Present
% Over PEL
a. Chromium III** PEL 0 . 5 ppm
Department Number & Name 0 (NA)
DNA
% Over PEL Without
Protection
DNA
b. Chromium VI** PEL Not Established - TLV 0.05 mg/m3 Fetal Toxin > 0.05 mg/m3
Department: Number & Name 0 (NA)
DNA
DNA
These chemicals have been included in the Plant's monitoring schedule but have not been monitored yet.
NGC 12955
IH-201A
Revised 09/25/91
Number of
Samples
% Over PEL
% Over PEL Without
Protection
c. Lead PEL 50 jKJ/ro3 Fetal Toxin if blood lead level <30ug/100gm blood.
. Department Number & Name 0 (NA)
DNA
DNA
d. Vinyl Chloride PEL 1 ppm Fetal Toxin <1 ppm
Department Number & Name 426(SI
62(NA)
16(NA^
e. Cadmium** 0.2 mg/m3
Department Number & Name 0 (NA)
DNA
DNA
f. Tin**
2 mg/m3
Department Number & Name 0 (NA1
DNA
DNA
g. Dust**
15 ppm Total Dust 5 ppm Respirable Fraction
Department Number & Name 0 fNA^
DNA
DNA
* These chemicals have been included in the Plants monitoring schedule but have not been monitored yet.
A plan has been written to address all Over Exposures without personal protection.
NA
These chemicals have been included in the plants monitoring schedule but have not been monitored yet.
DEG 12/10/92 ihchkl.pla/13
MGC 12956
IH-201A_______ __ Revised 09/25/91
B. INDUSTRIAL HEALTH PROCEDURES
1. Respiratory Procedure
a. Written
b. Selected per Hazard
c. Training d. Fit Testing e. ' Medical Examination f. Cleaning g- Storage h. Inspection i. Approvals
j - Usage
Asbestos Handling and Disposal
a. Sources Identified b. Monitoring c. Medical Examination d. Demolition and Removal e. Protective Clothing f. Written
NA
s
S
s
S S S
s s s
s
DNA DNA
R
DNA DNA
3. industrial Health Exposure Evaluation and Honitoring
a. Strategies
1. OSHA Compliance 2. Exposure Evaluation 3. Special Requests
NA S S
b. Sample Procedures c. Analytical Procedures/Cross Check Program d. Employee Notification,Interview &
Documentation (Excellent program)
S _S. _S
4. Radiation
a. Hazards Identified and Labeled b. License Requirements c. Records d. Dosimetry Program e. Periodic Leak Checks f. Radiation ProtectionOfficer
DEG 12/10/92 ihchkl.pla/14
DNA DNA DNA DNA DNA DNA
NGC 12957
IH-201A Revised 09/25/91
5. Ventilation for Health Hazard Control
a. Periodic Flow or Maintenance Checks b. Laboratory Hoods
NA
1. Yearly Flow Checked 2. Rating or Flow-Rate Posted
DNA... DNA
c. ' Modifications Reviewed d. New Systems Reviewed
S S
6. Leak Detection
a. Written b. Area Monitoring Response c. Leak Repair Control
DNA DNA DNA
7. I.H. Equipment Calibration
a. Audiodosimeters
1. Daily Field Calibration 2. Laboratory Calibration
b. Sound Level Meters
1. 2.
Daily Field Calibration Laboratory Calibration/Three Years
c. Acoustic Field Calibrators Every ThreeYears d. Radiation Detection Device - Annually e. Area Monitoring Devices (Self calibrates) f. Personnel Monitoring Pumps
S NA
S NA
DNA DNA DNA S
8 Laboratory Safety
a. b.
c.
d.
4 Chemical Hygiene Plan (in use) Chemical Hygiene Officer Named
Lab Hoods Adequate for Hazard
Personnel Protective Clothing and
Equipment
NA S
S S
9. Bloodborne Pathogen
a. Written ExposureControl Plan b. List of Job Covered bythe Plan c. Training d. Immunization
DEG 12/10/92 ihchkl.pla/15
S S S S
NGC 12958
IH-201A Revised 09/25/91
10. Potable Water safety
a. Written Policy b. Water Systems Identification c. Cross Connection Avoidance
(All systems are tagged)
NA NA NA
C. Hearing Conservation and Noise Control
1. All jobs with an eight hour TWA exposure of 85 dBA (50% dose), have been identified.
2. Noise hazardous (BFG > 85 dBA) areas have been posted.
3. A formal list is available at the plant specifically designating hazardous and non-hazardous noise exposure jobs.
4. Records are available showing monitoring results for those jobs that were monitored. NOTE: A copy of monitoring result must be entered into the Medical Surveillance System in Bath. The plant must retain its records for at least two years (OSHA).
a. Monitoring for OSHA Noise PEL by Area From (month/year) 1/1/92
to Pre
S 2A
s
s
Number of
Samples
% over 50% without Hearing Protection
% Over 100%
Hearing Protection Action Level 50% Engineering Control PEL 100%
Department Number & Name OfNA)
DNA
5. When employees working on noise hazardous jobs are monitored, they are informed of the monitoring results (OSHA).
DNA S
DEG 12/10/92 ihchkl.pla/16
NGC 12959
IH-201A Revised 09/25/91
Engineering and/or maintenance efforts are being directed at reducing noise in those areas/jobs with an eight hour TWA of 90 dBA or greater (100% dose)(OSHA)Note: Details of this effort must be documented.
Hearing protection worn in all noise hazardous areas.
Hearing protectors in use are capable of reducing employee noise exposures to below 85 DBA (NOTE: "NRR" or attenuation factor on hearing protector package. Consult with Industrial Health in Cleveland if more information is needed).
Employees are provided a choice of two or more different types/varieties of hearing protection (OSHA).
Personnel working at noise hazardous jobs receive annual training which includes at least the following information (OSHA).
a. The effect of noise on hearing.
b. The purpose of hearing protectors, the advantage and attenuation of various types, and instructions on selection, fitting, use, and care.
c. The purpose of audiometric testing and an explanation of the test procedures.
Care is exercised to insure a proper initial fit and correct use of all hearing protectors (OSHA). NOTE: With inset-type hearing protectors (ear plugs), it is important that the ear canal be clear and free of impacted wax. The ears should be examined for impacted wax before plugs are fitted. If impacted wax Is found, it should be removed by a nurse or physician. Any employees complaining of an ear problem should be referred to medical personnel for examination.
IH-201A Revised 09/25/91
12. Audiometric examinations are provided for:
a. All new hires (pre-employment). b. Transfers to noise hazardous jobs. c. Employees working on noise hazardous
jobs (annually).
_____S_ _____S_ _____S_
NOTE: Details for conducting proper audiometric exams are provided in BFG's
OHP Manual, Section 5.05.
13. Audiograms are permanently retained for each employee.
S
14.
Employees with audiograms showing a standard threshold shift (STS) are notified of this fact in writing within 21 days (OSHA). NOTE: Employees showing a STS are to be retested within 30 days.
S
15.
Employees exhibiting a STS are refitted with hearing protection and retrained in its use (OSHA). NOTE: Hearing protectors with greater attenuation may be needed.
S
16.
Employees showing shifts in their hearing are provided follow-up counseling based on the BFG quarterly Audio Action Report and Section 5.0-5 of the OHP manual.
___S_
17.
Cases with a confirmed average 25 dB shift from the original baseline in the frequencies 2000, 3000, and 4000 Hz, either ear, are recorded on the OSHA 200 Log.
___S_
18.* The audiometer in use satisfies requirements of the ANSI standard 3.6-1969.
___S_
19.*
An acoustical or biological calibration is performed daily on the audiometer before use. NOTE: Results of these tests must be kept on record for at least one year.
___S_
20.*
An acoustic check is performed on the audiometer annually,
NOTE: Audiometer must meet requirements Of ANSI S3.6-1969.
___S
DEG
12/10/92 ihchkl.pla/18
NGC 12961
IH-201A Revised 09/25/91
21. * An exhaustive calibration of the audiometer is performed at least every two years by the manufacturer or his approved agent. NOTE: (#18, #19, #20) Results of all checks and calibrations must be kept on record.
___S_
22.
A copy of the OSHA noise standard is posted in the workplace or is available to employees.
___S
*Numbers 18. 19. 20. 21 - Where an outside audiometric testing service is employed, it must be established that these requirements are satisfied.
D. Check List Totals
Satisfactory Needs Attention Does Not Apply
72 25 65
DEG 12/10/92 ihchkl.pla/19
NGC 12962