Document RJvMv7XnyGgYnOgDwVLk3O67B

HEATINC VENTHATINC AIR CONDITIONING GUIDE 1942 A53 and A120 combines the schedule thicknesses of the American Standard for Wrought-Iron and Wraught-Steel Pipe, A.S.A. B36.10, and the old series designations. Standard-weight pipe is generally furnished with threaded ends in random lengths of 16 to 22 ft, although when ordered with plain ends, 5 per cent may be in lengths of 12 to 16 ft. Five per cent of the total number of lengths ordered may be jointers which are two pieces coupled together. Extra-strong pipe is generally furnished with plain ends in Table 2. Dimensions of Schedules 60 and 80 and Extra-Strong Pipe DiawIETEK, I N. -aa 1 2 (S Sa Circum Weight per Ft ference, In. Plain B Ends, Lb xT 1 1g 1 `J3 fr- 2e Transverse Area, Sals. *3 1 12 kB 2 3 BS 0.405 y. 0.540 M 0.675 0.840 0.215 0302 0.423 0346 0.095 0.119 0.126 0.147 0.314 0335 0.738 1.087 1.272 1.696 2.121 2.639 0.675 0.949 1.329 1.715 0.129 0.229 0358 0354 0.036 0.072 0.141 0.234 0.093 0.157 0.217 0320 ti 1.050` 0.742 0.154 1.473 1 1315 0.957 0.179 2.171 m 1.660 1.278 0.191 2.996 m 1.600 1300 0.200 3.631 3399 4.131 5.215 5.969 2331 3.007 4.015 4.712 0366 1358 2.164 2.835 0.433 0.719 1.283 1.707 0.433 0.639 0381 1.068 2 2375 2375 3 3.500 3M 4.000 4 4.500 1.939 2323 2.900 3364 3.826 a218 0.276 0.300 0.318 0.337 6.022 7.661 10352 12305 14.683 7.461 9.032 10.996 12366 14.137 6.092 7.298 9.111 10368 12.020 4.430 6.492 9.621 12366 16.904 2.953 4.238 6.605 8.888 11.497 1.477 2354 3.016 3.678 4.407 5 6 8 IOC 12 5363 6:625 8.625 10.750 12.750 4313 5.761 7.625 9.750 11.760 0.375 20.778 0.432 28373 0.500 43388 0300 54.735 0300 65.415 17.477 20313 27.096 33.772 40.055 15.120 18.099 23.955 30.631 36.914 24306 34.472 58.426 90.763 127.676 18.194 26.067 45.663 74.662 108.434 6.112 8.405 12.763 16.101 19.242 Length op Pipe, Ft per SqFt J1 M s1 2 s3 so Length op Pipe, Weight Ft Con taining ICuFt op Watbb, Lb per Ft 9.431 7.073 5.658 4347 17.766 396639 12.648 2010390 9.030 1024.689 6.995 615317 0316 0.031 0.061 0.102 3.637 2.904 2301 2.010 5.147 3.991 2.988 2346 333.016 200.193 112356 81.487 0.188 0312 036 0.77 ' 1.608 1328 1.091 0.954 0.848 1.969 1.644 1317 1.135 0.998 48.766 138 33.976 137 21301 236 16.202 3.84 12325 4.98 0.686 0376 0.443 0355 0.299 0.793 0.663 0300 0391 0325 7.915 738 5324 11.29 3.154 19.78 1.929 3235 1328 46.92 "c-xcra-etrong wrougnt-tron pipe has approximately the same wall thicknesses and weights as contained herein for steel pipe. For exact dimensions, see American Standard far Wrought-Iron and Wrought-Sted Pipe, A.A. B36.10. 1 ^Thicknesses shown in bold face type are identical with thicknesses for Schedule SO pipe for A.S.A B36.10. cSame as Schedule 60, A.S.A. B36.10. random lengths, of 12 to 22 ft, although 5 per cent may be in lengths of 6 to 12 ft. In addition to IPS copper pipe, several varieties of copper tubing are in use with either flared or compression couplings or soldered joints. Dimen-. sions of copper water tubing intended for plumbing, underground water service, fuel-oil lines, gas lines, etc., have been standardized by the U. S. Government and the American Society for Testing Materials. There are three standard wall-thickness schedules of copper water tubing classified in accordance with'their principal uses as follows: Type K--Designed for underground services and general plumbing service. Type L--Designed for general plumbing purposes. Type M--Designed for use with soldered fittings only. 344 CHAPTER 18. PIPE, FITTINCS, WELDING In general, Type K is used where corrosion conditions are severe, and Types L and M where such conditions may be considered normal as, for instance, in heating work. Types K and L are available in both hard and soft tempers; Type M is available only in hard temper. Where flexibility is essential as in hidden replacement workor where as few joints as possible are desired as in fuel-oil lines, the soft temper is commonly used. New or exposed work generally employs copper pipe of a hard temper. All three Table 3. Standard Weights and Dimensions of Welded and Seamless Steel Pipe* From Standard Specifications for Welded acd Seamless Steel Pipe of the American Society for Testing Materials, A.S.T.M. Designation A120. aSizes larger than those shown in the table are measured by their outside diameter, such as 14 in. out-* side diameter, etc. These larger sizes will be furnished with plain ends, unless otherwise specified. The weights will correspond to the manufacturers' published standards although it is possible to calculate the theoretical weights for any given size and wall thickness on the basis of 1 cu in. of steel weighing 0.2833 lb. bThe American Standard for Wrought-Iron and Wrought-Steel Pipe B36.10-1930 has assigned no schedule number to Double Extra-Strong pipe. ca 10 in. Standard Weight pipe is also available with 0.279 in. wall thickness, but this wall is not covered by adOScwhinegdutoleaNduempbaertru.re from the Standard-Weight and Extra-Strong wall thicknesses for the 12 in. nominal size, Schedules 40 and 60. Table 2 of the A*S.A. B36.10-1039, Standard for Wrought-Iron and Wrought- th< rppular Standard and Extra-Strong wall thicknesses (0.375 in. and 0.500 in.) have been Standard dimensions, weights, and diameter and wall-thickness tolerances for these classes of copper tubing are given in Table 4. Copper pipe is also available with dimensions of steel pipe. Refrigeration lines used in connection with air conditioning equipment also employ copper tubing extensively. For refrigeration use where tubing absolutely free from scale and dirt is required, bright annealed copper tubing that has been deoxidized is used. This tubing is available in a variety of sizes and wall thicknesses.