Document RJk56O1MbkbdmqkQDVJ40rO57
Inspection ID
Class I and II Well Inspection Form
US Environmental Protection Agency - Region 4 Underground Injection Control Program
61 Forsyth Street SW, MC 9T25, Atlanta, Georgia, 30303 Phone: (404)562-9424
Inspector(s):
Anthony Shelton Carol Chen
_ (lead), ,
EPA Well ID#: Year-Month-Day: 2 0 2 1 - 1 1 - 1 8
EPA Permit # (or RA): Page 1 Of 2
Carl Weller
Start Time: 11:32 am End Time: 11:40 am
Facility Contact Information
Facility Name:
PETRO HARVESTER OPERATING COMPANY, LLC
Street Address:
1107 W 6th St (office address)
City:
Laurel
County:
Jones
Nature of Business:
Oil and gas extraction industry
Facility Owner/Operator: PETRO HARVESTER OPERATING COMPANY, LLC
Email:
kerry.allen@rockallenergy.com
Facility Contact (if different):
Kerry Allen, Sr. Operations Manager
O/O Mailing Address: 1107 W 6th St (office address)
City: Laurel
County:
Jones
State: MS
Zip: 39440
Phone:
601-651-2100
Phone:
601-651-2105
State: MS Zip: 39440
Well Data from File
Well Name & #:
Laurel Field Unit (LFU) 36-13 #1
Well Type (see table):
Produced Fluid Disposal, UIC Class II
Latitude (N):
31.69891
Longitude (W):
State Permit: API#2306720409-01-01
-89.1613
Elevation (ft): 218'(Gr)
Injection Method (check applicable): Casing Injector; X Tubing & Packer; Cemented Injection Tubing
PBTD@4106'
Other:
Total Depth (ft): 11,500' Inner Casing Size (in): Inj. Zone: Open Hole; X Perforated; Top(ft) 4,020'
5 " Tubing Size (in): 2 "
Packer Depth (ft): 3943.98'
Bottom(ft): 4,078'
Max. Injection Pressure (psig): 682 psi
Latitude (N): 31.69890
Longitude (W):
-89.16133
Elevation (ft):
EPA GPS ID: SX8123 Well Status (see table): TA If not Active, Reported Date Last Active: 9/1/2016
Nature of Injected Fluid(s) if any: Produced fluids
General Condition of the Well Site:
NA
Field Measurements and Observations
Notes & Comments (include discrepancies from database values): Tubing gauge: 0 psi Annulus gauge: 0 psi Field hand on-site stated that no injection pump was on this location since 2016 and tanks may contain
some rainwater along with produced fluids. 40% produced fluids were visible in 2 tanks of 400 bbls, 60% produced fluids were visible in 4 tanks of 210 bbls.
Perforations provided by field hand on-site are: 4,020' to 4,034' 4,050 to 4,078
See reverse for additional observations, comments and photo log
Owner/Operator Representative (Optional)
UIC Inspector
Name: Signature:
Name: Signature:
Anthony Shelton
ANTHONY SHELTON
Digitally signed by ANTHONY SHELTON Date: 2022.01.19 10:05:38 -05'00'
Version 2018-04-18
Inspector Carl Weller's signature:
CAROL CHEN Digitally signed by CAROL CHEN Date: 2022.01.18 17:41:32 -05'00'
Inspector Carol Chen's signature:
Inspection ID
Field Measurements and Observations (Cont.)
Class I and II Well Inspection Form
US Environmental Protection Agency - Region 4 Underground Injection Control Program
61 Forsyth Street SW, MC 9T25, Atlanta, Georgia, 30303 Phone: (404)562-9424
EPA Well ID#: Year-Month-Day: 2 0 2 1 - 1 1
EPA Permit # (or RA): Page 2
- 1 8 Of 2
(Cont)
Laurel Field Unit (LFU) 36-13 #1
36-13-1 Class II Well/SPCC Observations:
The operators informed the inspection team that the drilling field has two 16,800 gallon
aboveground storage tanks (AST)s on site that are approximately 40 % full with produced fluids
and four 8,820 gallon ASTs on site that are approximately 60 % full with produced fluids. The
inspection team did not observe any other ASTs in this drilling field.
The P.E. certified SPCC Plan for this drilling field stated that soil should be used for secondary
containment for the six ASTs.
The tank farm uses soil (permeable material) as a secondary containment for the six
aforementioned ASTs.
The six ASTs were badly rusted and looked like they were poorly maintained.
Team's observations/comments:
We Inspected 8 wells that day, with a total of 9 people: 4 from Petro Harvester, 2 from MSOGB and 3 from
EPA. All inspected wells were located in areas that were fenced and gated. All the pumping units and injection
pumps were in good condition and operated almost silently. The well locations seemed to be kept clean and
organized. The focus of this inspection was well 36-13-1 which was TA with 0 psi on Tubing and 0 psi on
Annulus. Also, the well was chained and locked in the closed position.
Photo Log
Photographer:
Carl Weller
Photo ID:
107
Time: 11:33 am
EPA Camera ID: Lat (N): 31.69887
SX8123 Long (W)
Description: Photo ID:
overview, no injection pump, (2) 400 bbl tanks, (4) 210 bbl tanks
108
Time: 11:36 am Lat (N): 31.69896
Long (W)
Description: well site
Photo ID:
Time:
Lat (N):
Long (W)
-89.16132 -89.16129
Description:
Photo ID:
Time:
Lat (N):
Long (W)
Description:
Photo ID:
Time:
Lat (N):
Long (W)
Description: Photo ID:
Time:
Lat (N):
Long (W)
Description:
Owner/Operator Representative (Optional) Name: Signature:
Inspector Carl Weller's signature:
UIC Inspector
Name:
Anthony Shelton
ANTHONY
Signature: SHELTON
Digitally signed by ANTHONY SHELTON Date: 2022.01.19 10:06:02 -05'00'
Version 2018-04-18
Digitally signed by CAROL
CAROL CHEN Date: 2022.01.18 17:42:06 CHEN
Inspector Carol Chen's signature:
-05'00'