Document RJjZ0Z70aqxOeE2KXOG5qO0Rz

Hi Air fro/v blows'". T! WCL to s*k srownii JET 1 i % V: i. I VI M HONS 049675 1 L A CONT.fyuC'JS CniSK'NATOA- FLOW SHCfT *-*" *> !*-------------HJ |s-'i-c4 |Nome 11 |mwcuw TS-B-7B3- > ' 'j L i m w.............................. ......... .............. ...... c r ic n ji w ' a x f t X ^ ......... X 'N l'W tiLV S ^X l ^ ....... ...... "(j-'j icecP //*/s ei*e AT sHoerr ecE of prj*-. paper r trru* "' fc'' Avm.no. . tomtm 1 TS-Bao#-f- MOMS 04967? m b r a il MONS 049678 STAMDARD MAHOFACTORIBG PROCESS FOR AROCLOR III. . PROCRS8 IK DETAIL A. Batch Liquid Chlorlnators Crude Liquid Aroclors are produced by batch chlorination In a vortical vassal. Tha raactlon Is coolad by artsmat air coolad hast exchangers and agltstad by a circulating puap. Blphanyl la chlorinated with chlorine gas added at tha bottoa of tha vaasel. HC1 gas vented at tha top of tha chlorlnator la a by-product which la recovered in the Muriatic Add Department. Crude Aroclor produced in batch chlorlnators la tranafarrad to tha blowing operation when tha chlorination la completed. Chlorine gas la fed to the chlorlnators from tha Chlorine Plant and/or from tank care. A chlorlnator charge (3,000 lbe.) of specification grade Blphanyl la pumped to tha chlorlnator charge tank from a Blphanyl storage tank. One and one-half (1-1/2) pounde of Ferric Chloride la slurried In Aroclor and dumped Into the charge tank with each chlorlnator charge. Tha Biphenyl and Ferric Chloride la agitated for a minimum of 13 minutes and than transferred to the chlorlnator. Aroclor 1142 can be used to charge a batch chlorlnator for the production of 1148, 1134, 1160, or 1162. When 1142 la used for a chlorlnator charge no Ferric Chloride la added. After the chlorlnator haa been charged the circulating pump la started and then the chlorine feed la put on tha chlorlnator. As the chlorination progresses tha specific gravity la cheeked at Intervals until tha desired gravity has bean attained. Whan a chlorlnator la flnlahad It la tranafarrad to a blowing tank. B. Continuous Chlorlnator Operation Tha continuous chlorlnator operation conalata of four cascade flow chlorlnators in series where specific levels of chlorination occur. Blphanyl, with Ferric Chloride added, la fed continuously Into the first chlorlnator where tha material la chlorinated and overflows to the second chlorlnator. Tha flnlahad product comae off tha final unit, flows Into a catch tank and la pumped to a continuous blow tank. The material la pumped from this blow tank MGNS 049679 Aroclor Manufacturing Proem Free*** In Dntall 2. to anothar blow tank for additional blowing. Chlorlna la (ad to aaeh chlorlnator continuously. Thla chlorination eyatam can ba raducad to thraa (3) cblorlnatora In aarlaa In caaa problaaa occur with ona unit. Normally 1142 la tha only Aroelor produced on tha contlnuoua ayataa, howovar, other Liquid Aroclora can alao bo produced with tha chlorlnatora aat for different levala of chlorination. C. Biphenyl Ml Tank and Feed Tank Whan Blphanyl la needed for the contlnuoua chlorlnator operation a charge la punped froa a Biphenyl atorage tank to tha nix tank. Thraa and ona-half (3-1/2) pounda of Ferric Chloride la added to the tank. The agitator In the tank la atartad and tha Blphanyl and Ferric Chloride la agitated until a charge la needed for the Blphanyl fead tank. Tha feed tank la located under tha ads tank. The feed tank low level alarm oounde the annunciator ayatam at 25% full, at which time the mix tank batch la dropped Into tha feed tank. Thla will allow a minimum of ona hour agitation In tha mix tank. Tha agitator In tha faad tank tuna contlnuoualy while Blphanyl la being fed to the flrat atage of tha contlnuoua chlorlnator operation. D. Batch Solid Chlorlnator Crude Solid Aroclora ara produced by batch chlorination idiaa a weighed quantity of Biphenyl, Santowax, or a mixture of tha two la chlorinated In a vertical reaction vaaael with Ferric Chloride aa a catalyac. Chlorine gaa la added at tha bottom of tha veeaal. By-product HC1 gaa vented at tha top of the chlorlnator la recovered In tha Muriatic Acid Department. Crude Solid Aroelora produced In batch chlorination are tranaferred to tha blowing tank operation when the chlorination la completed. (Tha only exception being 1166 which la not air blown but pumped dlractly from the chlorl nator to the atlll). Chlorine gaa la fed to the chlorlnator from the Chlorlna Plant and/or from tank care, I. Blowlna Tank Operation Crude Aroclora produced In tha chlorlnatora are air blown for a minimum of one hour, for removal of reeldual HC1, before tha material la fad to tha atllla. Steam la maintained on the eolla MQNS 049600 Aroelor Manufacturing Procaaa Procaaa In Datall 3. of tha Liquid blowing tanka during thla operation. Thermlnol haat la maintained on tha coll In tha Solid blowing tank, kasldual HC1 blown out of tha cruda Aroelor la drownad In a water ejector which pull* a cllght vacuum on the blowing tanka. P. Liquid Still. Aarated crude Liquid Aroelor from a blowing tank, or a roof tank oontalnlng aerated Aroelor, la fed to tha atlll tank. Hydrated line la added to the crude Aroelor. Vacuum la appllad to tha atlll and the Aroelor la circulated through the furnace coll and heated to the vaporisation tenperatura. Vapors pass up an open colunn to tha condenaer. Distilled Aroelor la collected In a receiver and then trans ferred Into a blending tank. Distilled Liquid Aroclors are treated with Attapulgue larth la tha blending tank, filtered, analysed, and packaged or held la storage. Still residue or bottoas are sold as Montars or discarded. G. Earth Treatment and Filtration All Liquid Aroclora ara traatsd In the blending tank with Attapulgus Earth. This earth la dried In an oven for a alnlnua of four hours at a tenperatura of 210-250C. The material, with the earth added, la agitated and then punpad through the filter press and back to the bland tank. When no earth la vlslbla In the aatarlal It la then dlractad to a filtrate receiver. The filtered Aroelor la then ready for drawing or tranafer to a atorage tank. H. Solid Still Aaratad Cruda Solid Aroelor frou a blowing tank la punpad to the Mo. 4 still pot. Hydrated line la added to the crude Aroelor. Vacuum la appllad to the atlll and the Aroelor la circulated threugh tha furnace coll and heatad to tha vaporisation tenperatura. MUNS 049081 Arcclor Manufacturing Procaaa Proeaaa In Datall 4. Vapora paaa up on opan colunn to tha eondanaar. OlatIliad Arnolor la collected In a receiver. Quality of tha dletllled Solid Aroclora la analyaed by tha laboratory, and If In opacification, It la draun directly from tha receiver Into eulteble containers or tranaferred to the flaker operation. Still residue or bottoms are sold as Montars or discarded. I. fMtaglBE Solid Aroclora are packaged In fibre druns, galvanised drums, galvanised cana and in paper bags. Liquid Aroclora ara packaged In steel drums and cans. Thasa drums and cans ara lacquer lined. Liquid Aroclora ara also loaded Into tank care and trucks. HONS 049682 HONS 049683 STANDARD MANUFACTURING FN0CIS8 FOR AROCLOR5 COMRHIB ON THN PROCK88 A. LIQUID AROCLOK3 1. Chlorination a. Temperature Chlorination tanparaturaa of 120C or lower yield a product which will not paaa tha eteblllty taata on alactrlcal grade Aroclora. A minimum of 130C hat baan tat for tha chlori ne tora. An upper temperature limit la not defined aa critical to high quality Aroclor production. A practical limitation la governed by tha lncreaaa of overhead product loaa to tha off-gaa collection tank. Tha normal temperature range la batwaan 1A0C and 170C. b. Ctttlvct The baakat containing a bad of Iron tumlnga In the chlorlnator provldea contact aurfaca for tha Chlorine and Biphenyl, and tha Iron raacta with tha Chlorine forming Forrlc Chloride which la tha actual catalyat. Conaumptlon of tha turning! makaa It neceaeary to lnapect tha chlorlnator eami-annually and replenlah the turnlnge if neceaaary. Ferric Chloride (anhydroue powder) In tha amount of 0.051 la added to tha chlorlnator charge to provide aaauranca of adequate catalyat at all tlmae during tha chlorination. It la Imperative that tha Iron turnlnge in each chlorlnator ba lnapectad eami,annually. Aroclor euppllad to General Electric and Heetlnghouae muat be produced In chlorlnatora containing tha baakat. (Frlor to any ehlpment of Electrical Grade Aroclor being chipped to General Electric and Vaatlnghouee from a procaaa where the backeta arc removed. Marketing will review the proceaa change with both cuatomera.) The catalyat le added to the chlorlnator charge tank or min tank (contlnuoue chlorlnatora) and agitated for at leaat 15 mlnutaa but uaually at leaat an hour before charging or feeding tha chlorlnatora. MCL and WGE Aroclor Departmanta do not pre mix tha catalyat. Raaaarch hac Indicated tha tendency to producing unatabla Aroclora can be attributed to Improper catalyat concentration which may ba brought about by lnaufflclamt mixing prior to chlorination. MONS 049684 Coamnta on the Froeaaa Aroelora 2. Frea Chlorlna In tha off-gaa from an Individual chlorlnator or from tha vant at tha HC1 abaorbar sowar box indleataa problem operation In tha Aroclor Department. It can be cauaad by Inadequate reaction of tha Biphenyl and might Indicate formation of unatabla Aroclor. If thla altuation occur* it should be corrected lmnedlately. Taka aamplaa from tha In dividual chlorlnator off-ga* and have them analyaed for fraa chlorlna by tha laboratory. Check grab aamplaa from each chlorlnator of tha crude Aroclor being produced and obaerva it for unuaual appearancaa. Inadequate amount* of catalyat present aa Farrlc Chloride or Iron turnings can causa fra* chlorlna In the off-gaa line. In caaa this situation occurs and cannot ba resolved, remove tha chlorlnator from operation. Contact department supervision lmssadlataly. A badly worn chlorlnator distributor can also cause from chlorine In tha off-gas line. c. Chlorlna Although tha affect of air In chlorlna on Aroclor quality la unknown, tha amount of air in chlorlna does affact tha chlori nation rata and tharafor* affect* tha production rata. Problems with tha dhlorln* vaporiser can occur which would allow liquid chlorlna to be fad to tha chlorlnator*. In caaa this should happen, slug* of liquid chlorlna would b* fad Into tha chlorlnator possibly causing excessive reaction or axeasslv* loss and vantlng of chlorine to tha atmosphere. Chlorlna In tha HC1 off-gas plpa Unas could causa extrama reactions which would generate excessive heat. This reaction can causa a plpa llna to bacoma rad hot and malt tha plpa llna In two. This would result In chlorlna gas escaping to tha atmosphere. Ivary effort possible should b* mad* to operate tha vaporiser with the control system provided. Entrainment of Biphenyl or crude Aroclor Into tha HC1 lines can occur from axeasslv* chlorlna rates. This ssma sltustlon can occur In caaa tha Chlorlna Flant la blowing too much air. Thla can ba checked by observing the off-gas from tha chlorlnatora In tha sight glasses on top of the Brink Damlatar on aach chlorlnator. Normal operation of tha chlorlnator should b* to minimise this carry-ovar. Abnormally high or low chlorlna header pressures can causa operating problem*. High chlorlna header pressure cause* problems within tha Chlorlna Flant to HQNS 049685 Consents on tha Process Aroelors 3. tha department operating paraonnal. Chlorlna fumes ara foread back Into tha Chlorlna Dapartaant and at tlnaa aulfurlc aeld can ba blown from tha Naah compressor system. Slnca thla praaanta a safety haiard to the dapartaant paraonnal every effort should ba made to eliminate high praasura problems. Low chlorine preaaura can cause operating problems within tha Aroclor Department. In cases of axtrama low praasura, tha crude Aroclor could back up In tha chlorine line and begin blow-back Into the chlorine header. d. Chlorlnator Off-Cas Collection Tha danlstar on top of tha liquids collection tank la used as a final knock-out for Aroclor and Biphenyl antralnad drop lets In the MCI gae syetem. Usually this system will be operating with the steem tracing around tha outer shall shut off. Whan tha ataan tracing la turned on It will allow vapors to be carried through tha demister to tha Muriatic Add absorber. Tha sight glass on tha discharge of tha demister can ba checked to determine If antralnad droplets ara being carried over. Tha steam la Installed for uaa to unplug the deulatar In case thla should occur. Tha trappings from thla clean-up syatam ara used to produce Aroclor 1148 and 1162 only. Tha reason for thla Is to ba sure that wa do not produce any unstable electrical grade Aroclor, It la extremely Important that tha tempered vaeer system on tha liquid HC1 off-gas condenser ba drained during excessive cold waather If It la shut down. Tha bottom head on the con denser has drain valves at two locations. Both of these drain valvas must ba open to remove water from tha off-gas condenser when the system If shut down. 2. Alt Blowing of Crude Aroclora Air blowing of crude Aroclora takas place with compreasad air from air blowers. Thb air is not dried by any means other than that caused by compression and cooling in tha air blowers. Judging by tha corrosion exhibited around nosslaa atop tha blowing tanks a good arguamt can be made for thoroughly dried air. Wat air nay also ba the causa of poor electrical propertlas that occasionally occur during period of rain and high humidity. Wet sir ean also carry In chlorides, SOj, and HjS from the atmosphere. An air dryer would tend to scrub out these undesirable gases. MONS 049686 on th* Process Aroclora 4. 3. Distillation Vacuum trouble on th* (till* 1* usually cautad by flashing of product, pluggad vacuum llnaa, or improper functioning of the vacuum jats. Flashing can usually ba atoppad by operating the still at a slower rate or increasing tha flow of cooling water to the vapor condeneer. Vacuum trouble can be traced systematlcally from the Jets and usually Isolated. 4. garth Treatment Exclusion of atmospheric mqlstura is naturally Important whara high electrical resistivity is required and of course the Attapulgua earth neada to ba well dried. All liquid Aroelors are earth traatad at the Anniston Plant to decraase the risk of contaminating electrical grade with non-electrical grade Aroclora. There are too many common lines downstreem of th* etill* to chance non-tfeatment of non-electrlcal grade Aroelors. &S11& Incomplete aeration in tha blow tanka, or the addition of in sufficient lime to the still pot, will cause high acidities. High inorganic chlorides either indicate contamination or tha presence of attapulgus earth in the product caused by a poor filtration. Batchea with high color usually indicate excessive gas heat on the heating colls or air leaks in the vacuum system. A distillation carried too far will also show a dark distillate from tha distillation of colored material from tha residues. Another reason for color can be the material formed when chlori nating at low temperature* or with insufficient catalyse. Batchea with specific gravities, softening points and viscosities out of specifications esn indicate over or under chlorination*, or in complete draining of tha procaas equipment when switching from one type of Aroclor to another. Iron has a deleterious affect on the electrical properties of the distilled Aroelors; therefore, tankage, process piping and pumps from th* still receiver through tha remainder of th* process are either aluminum, tin and sine sprayed or are constructed of monel, stainless steel or bronae. 6. Special Crades a. Export Aroclor 1242 Th* export specs on 1242 call for a resistivity of 5,000 min. and a Biphenyl content of 0.051 max. Domestic spec* call for 500 min. resistivity and no spec on Biphenyl content. Th* HONS 049687 Biphenyl content of 1242 node on the continuoue chlorlnetore averagee below the 0.05X max. epee end therefore ceueee no production probleae. To meet the 5,000 win. reeietlvlty epee the 1242 ie eerth treeted two to five tlmee ueing normal proceduree until the reeietlvlty exceede 7,000 (dept, epee) end then drummed out fron the flltrete receiver. b. Export Aroclor 1254 The export epece on 1254 cell for e reeietlvlty of 5,000 nln. end e Biphenyl content of 0.0251 nex. Domeetlc epece eell for 500 nln. reeietlvlty end no epee on Biphenyl content. To neet the 5,000 nln. reeietlvlty epee the 1254 le eerth treated two to five tlmee ueing normel proceduree until the reeietlvlty exceed 7,000 (dept, epee) and then druamnd out from the filtrate receiver. Two methode have been tried to aeeure low Biphenyl content. (1) Batchee three through eight In the normal tan batch dletlllatlon run have a greater tendency to neat the Biphenyl epee than the remaining four. laeh batch la enalyeed for Biphenyl and then earth treated whan in epee. Thle method la hit and mice and haa about a 50X reliability of euccaea and ceueee etlll downtime. (2) Aroclor 1154 la chlorinated from low Biphenyl 1142 rather than Blphanyl. Chancae of eueeeae ara eo graat that all ten etlll batchee have been earth treated and plaeed.In an empty etorage tank and than additional earth treatment la aeheduled to avoid generating etlll downtime. The aecond method le uaed whenever poaelble and haa reeulted In better Inventory control of export 1254. Safety Biphenyl la flaamabl* and burning ahould never be done la ereaa where Biphenyl or Biphenyl vapora are preaent. Light Aroclora are alto flammable. The vlecoua Aroclor olle and the raaina do not aupport combustion when heated alone, even at their boiling polnta temperature* above 350C. Dermatology and Toxicology Aroclor* do not produce primary Irritancy or eenaltltatlon of the akin. At ordinary temperaturea Aroclor* have not preeanted in duetrial toxicological problena. If Aroclor* ere uaed at elevated temperaturea aueh aa 200 or 300C In open eyetama, methode nuat be dealgnad to axhautt any vapor* arlalng from thee* open eyateme. HONS 04968B CMnati on tho Proceai Aroelor* 6, B. SOLID AR0CL0R8 1. Chlorination Spaclal flaxibla piping jolnta hava baan mada to tha walgh tank alnea thla tank la placad on aealaa. Actuation of tha aeala ayatam will raqulra movement of thla tank approximately 1/A inch. Thaaa flaxibla piping Jolnta ahould ba carafully lnapactad to ba aura thara ara no laaka alnea tha material contained la than la axtrenaly hot. Staan la provided on tha tranafar llnaa and tha coll to the walgh tank. Prom tha bottom piping on tha walgh tank, all tha tranafar llnaa and colla in tha Solid Aroelor proeaaa veasala hava Tharmlnol haat until tha and of tha proeaaa at tha flakar hold tank. Tha No. 9, Solid Aroelor, chlorlnator doaa not hava a baakat of Iron tuminga. Due to thla. It la abaolutaly nacaaaary that five pounda of ferric Chloride be added to each chlorlnator charge In the walgh tank. Plugging of tha off-gaa condeneer In tha Sollda Clean-Up Syatan can occur. To unplug tha off-gat condenaer tha temperature of tha Tharmlnol ayatam la elevated aa required. During thla time, tha off-gaa condanaar can ba by-paaaed. The Sollda knock-out tank la provided with a drain ayatam to empty tha tank completely whan produete ara to be changed on tha No. 9 chlorlnator. Thla will eliminate contamination In tha weigh tank. 2. Air Blowing of Crude Aroelor Tha tame comnenta on eorroalon for Liquid Aroclora hold true for tha Solid Aroelor blow tanka. Undlatlllad Aroelora 2565 and 5060 are lima treated In tha blow tank to give a neutral add number. Flaked 5060 on tha add aide will eauaa the baga to fall. 3. Pletlllatlon Vacuum problema on tha Aroelor atlle ara uaually dua to flaablng of product ovar, plugged vacuum llnaa, laaka In tha atlll ayatam, laaka at pump packing, water adjuatmant on lnear-eondanaar on Jata, changea In ataam praaaura to tha Jata, or problama In the Jat noaalea. Flaehlng can be atoppad by adjuatlng tha coolant flow on tha coadenaar or operation of tha atlll at a alowar rata. Vacuum trouble muat be traced eyatanatlcally from tha Jet, to tha raealver, and than to tha atlll. MONS 049689 Coomeate on tha Procaee Aroclora 7. It li Important to bn turn thn eoll In thn Thormlnol cooling ayatem nurgn tank It covartd whan thn system la In operation. Thin aaauraa the circulating pump haa a positive auction and pravanta aurglng In the haatar coll. Thla will allow mora uniform control of tha temperature In the Tharmlnol cooling ayatorn. Cara muet be taken not to fill tha aurga tank too full during normal operation. Thla can cauae tha tank to run over whan tha circulating pump la atopped. A normal level will be about 6" to 12" in tha tight glaaa. Tha flow meaeurement recording Instrument for the etlll haatar ayatem la an extremely Important portion of tha controla for tha Ho. A atill ayatem. A eegmantal orifice la uaad for obtaining dlffarentlal praaaura raadlnga to Indicate flow. Thla orlflea ayetan la In a apecially daalgnad Tharmlnol Jacketed pipe taction. A apecially daalgnad d/p call racorda the praaaura raadlnga and lndlcatea flow. Tha orifice la daalgnad to allow tucking tha coll completely empty whan a dlatlllatlon la complete. Tha hole in tha orifice plate la fluah with tha bottom of thm pipe lino, Thla flow recorder lndlcatea low flow retaa at the and of a dla tlllatlon which alda tha operator In completing a normal operation. Lima addition to eha Solid Aroclor atill la vary Important. Cutting tha amount of lima below 200 lba. per batch reaulte in occaalonal off-color batche.a. - The longer atill bottoms are circulated In the heater the higher tha formation of HG1 and tha greater tha tendency to plug tha heater coll. Every effort should ba made to have Crude Aroclor available to charge tha atill at all times. A. Solid Aroclor 1268 Tha bottleneck In 1268 production la the chlorlnator. Increasing chlorine feed rates only Increases Biphenyl and low chlorinated Aroclor carry-over to the off-gas collection system, and Increases tha tendency to ovar-chlorlnatlon and Its ansulng problsns with fraene-up of llnaa and equipment (hold points greater than 17SC). Tha atill haa been found to run batter when thara la feed always available. Circulating of still bottoms while welting on crude Increases the breakdown of the Montar Into more vlsevus aaterlal and hydrogen chloride. Draining tha atill between batehaa In creases the tendency to plug tha heater coll. MONS 049690 Comment* on tho Frocaa* Aroelori 8. To move tha bottleneck from tha ehlorlnator to tha atlll require* charging tha ehlorlnator with 1142 and chlorinating at a rata high enough to Inaura flnlahlng tha batch bafora tha atlll batch la completed. Other higher chlorinated crudee can ba charged to tha ehlorlnator but they will not ba a* readily available aa 1142 from the contlnuoua ehlorlnator*. MONS 049691 A ' ^ r?uiPMC.MT - A'f *-( K/A l- C- CpaJSIAnTS T> - Or/LiTit'S EL- 'Pcksc>^/JCl V" W^A,IAJ<*J ^ 6j" aIaTC^IAU E^AIAa)^ M' Pcur^ J- -Peoc-3S Cpajtpoi- 3'' ^A'feTV K! ' i. ' "TTme - (JWits/ A] - /V),sc . MUNS 049692 0^9693 mons STAJTOAID WUntACmiHB PtOCISS FOB ABOCLOK ArmiPff-* - 2Bnm wt Atm 200 - Balk Stoxaga Atm 500 - Chlorlnator Atm 600 - Still HONS 049694 aotmmx a - wjdimbht ust Aa - tnn BPUC ST08ACE XSSB 201 Eaulp--at Mo. 1 Aroelor Storage Tank 22-0077 Paacrlptlon 10' x 26* natal tprayed with aine and tin. Capacity 13,000 gallona. 202 Mo. 3 Aroelor 22-0089 Horiaontal, cylindrical die. 8'-0", Storage Tank length 30'-0". Matal aprayad with line and tin. Capacity 11,000 gala. 203 Mo. 2 Aroelor 22-0076-01 10' x 26' natal aprayad with aine Storage Tank and tin. Capacity 13,000 gallona. 20A Mo. 4 Aroelor Storage Tank 10' x 26' natal aprayad with tine and tin. Capacity 13,000 gallona. 203 South Pyranol 22-0108 14'-0" I.D. x 10'-0" high. Mis Tank Dag. D-64S3. 206 North Pyranol Mix Tank 6'-6" I.D. x 8'-2" Jacketed ataal tank. 208 Mo. 1 Storage Tank Pump Taker vertical aubnargad puap. Typo CL-A. Capacity 73 OIM. 209 Mo. 2 Storage Tank Pump Tabor vertical aubnargad puap. Type CL-A. Capacity 73 C9H. 210 Mo. 3 Aroelor 22-0663 12,000 gal. vertical elunlaun tank. Storage Tank Sac 22-0662, 19-0397, 19-0398, 9A-0179, 9A-0180, 49-0777, 28-0332. 211 No. 6 Aroelor 22-0662 12,000 gal. vertical cluniaun tank. 8torage Tank Sac 22-0662, 19-0397, 19-0398, 94-0179, 94-0180, 49-0777, 28-0332. 212 Ho. 6 Storage 19-0397 20-A-30, 3 x 2 - 13/110 Mark 11 puap Tank tag w/crane teal #9 outaIda QP-191, Baaa ataal plate #33 7TL Falk Spaear coupling. 049695 MONS appihm* a - iqvinnt list 2. Itai -213 '214 215 In. Hamimrn Ho. 3 Storage Tank Pup * . 19-039B Ho- 3 Stores* Tank Pup Ho. 4 Stores* Tank Puap 7 CB un/ivO'V& for* f> 20-A-30, 3 s 2 - 13/110 Mrk 11 Pup w/aran* aoal #9 outalSa QP-191 Bat* attal plat* #53 7PL Palk Spaear eoupllng. Tabr vertical cuburga# pup. Typ* CL-4. . Capacity 75 BPM. Tabar oartie*1 auburgaA pup. Typ* CL-4. Capacity 75 CPU. 7.,t, CrHeK io6 HONS 049696 apfhdxx A - iqcipmht list 3. nnjrmntrrm ItW Equipment loulp. Bo. ''SOS Ho. 9 Chlorla*tor 22-0774 ^506 Ho. 9 Chiorlaator 19-0494 Clroulating Pimp 507 Aroclor Cooler Ho. 9 ChlorlnAtor u'SOS Ho. 4 Chiorlaator 32-0260 Cooler . 309 Ho. 3 Chiorlaator 19-0495 Clreulatlag hop '^510 '511 Ho. 3 Chiorlaator Cooler Ho. 2 Chiorlaator Clreulatlag Puap 32-0261 19-0496 PoaerlPtloa Tortleal 4'-6" Ala. a 20' itralght Ida earbon ataal roaaol with dlahod haada (3" Seh. 60 eoll 75' tong). Capacity 2,390 go Hob*. Solf-prlalng, eoatrlfugal poap (Pacific 2-1/2" 88 typo 8PC, 10" lap*11or, 15 HP, 1750 MM, 440 rolt motor). Pump ha* a Crana Ho. 9 oataldo aoohoalc*l aoal. Coda QP-866. Capacity 250 CPM ot 73' TDH. l'-S" dl. x 18'-6" long, earboa (tool ho11 boat oxchaagar with 304-3/4" 0.0. 304 atalalaaa otool, 14 M0 x 11" long tubaa. Pour paaaaa on ThonUol Ida (tuba oldo). Capacity 1,400,000 BTO/howr. An alr-eoolad 1" M0 16.6' long ataal tuba with alualaua flaaod coolor far mowing hoat tram eruda Aroclor, 3' wide x 8' long x 6' high, ogulppod with aa Analn paowwatlc oporator t* adjuat louwaro (58 tuboa). Pan boa a 2 HP, 1800 MM, 440 rolt actor. Capacity 1,100,000 HID/hour. Solf-prlalag, eoatrlfugal puap (Pacific 1-1/2 L Typo S9C, 1-7/8" lapollor, 15 HP, 1800 MM, 440 volt actor). Poop hao a Craao Ho. 9 outoldo aohhaaloal oal, cod* QP-666. Capacity 220 0IM at 81' TDH. Sana Itoa 508 Sana ao Itoa 509 M0NS 049697 appbhdec a - iquimnR ust AHA sno A. its Sculp--nt Banlp. Ho. t/ 512 - 513 Ho. 2 Chlorlnator Coolor Ho. 1 Chlorlnator Circulating Punp 32-0262 19-0497 ^514 Ho. 1 Chlorlnator 32-0263 Coolar .515 Ho. 3 Blow Tank 22-0596 516 Ho. 3 Blow Tank Punp 517 Ho. 4 Blow Tank ^518 5/3 520 Ho. 4 Blow Tank Tm,*Wc Aphony1 Food Tank 22-0595 22-07S8 520-A Blphanyl Food Tank B & C Agitator & Drive uStl Blphanyl Food Punp 19-0498 - 522 v 523 Ho. 5 Chlorlnator Coalar Ho. 6 Chlorlnator Coolar 32-0264 . 32-0265 Daaerlotlon Sana a* Itarn 508. Sana aa Itan 509. Sana aa Itan 508. 7'-6" dla. a 7'-6" high Dog- D-234-4 Faarlaaa Punp - Modal 1-1/2 DS0.8, Sarlal Ho. 121336. Sana aa Itan 515. Faarlaaa Punp - Modal 1-1/2 BSO.8. 5'-6" dla. a S'-8" long, carbon ataal tank with dlahad haada. Tank aantalaa a 2" Seh. 80 coll approalnataly 90' long. Capacity 1,000 gallona. 6-blada, turbine typa, carbon ataal agitator with a 4 BUZ Faulk notar roduear driven by a 10 HP. 1800 Ml, 440 volt notor. Tha agitator baa a 2-3/4" dla. x 8'-8" long (haft. Capacity provldaa nadlun agitation. Salf-prlnlng, centrifugal punp (Coulda Modal 3196 AT8-260, 6-5/6" open lnpallar, 5 HP, 1800 KPM, 440 volt notar). Tha punp hae a Crane He. 9 outaide naehanlcal aaal. Coda QP-868. Capacity 60 6PM at 42' TDH. Sana aa Itan 508. Sana aa Itan 508. HUNS 049698 appbmdu a - iqnmaR list m> 5. ita Batlmrat **524 Mo. 7 Chlorliuitor Cooler Bft 32-0266 ^525 Mo. 8 Chlorinetor 32-0267 Cooler 1/526 Crude Aroolor Ceteh Teak 22-0789 52? Crude Aroolor Ceteh Teak Punp 19-0526 ^52 Contlnuoue Air Blow 22*0682 Teak *429 Contlnuoue Blow 19-0699 Teak Trentfor Pune t/330 Air Blouar Morth *531 Bolide Off-Ceo duetor 11-0338 1/532 Liquids Off-Cee Iduetor i- 533 Thornleal Surge Tenk 99 Chler. 22-0775 <336 Mo. 9 Surge Tank Pin* *535 Weigh Tank 19-0500 536 Weigh Tank pup? 19-0501 Pn.9imoB Sana as Iten 508. Sano as Ittn 508. S'-6" x 5'-8" stool Tortleel tank with flanged end dished top head. Capacity 1,000 gels. 100 GPM 9 75' heed - vortical heavy duty centrifugal Tabor punp CT-3 #393. 500 gallon stool tank. Purehaeod iron Dixie Stool 6 Supply Co. See MCC Dug. D-54#-3-0. Self-prlnlng, vertleal centrifugal punp (Tabor vertical subnorgad, CL2-382, 7-1/2" open lnpallor, 3 IP, 1800 IPM, 660 volt notor). Capacity 15 CIM at 45' TUB. Model 7 H - Spec. SM-48S-530. Purchased fron Sutorbllt Cory. S Fig. 4010 Scrubber and SK 6060 Separator Box Havog 8 P.l. Coast. 6" Suet. 6" Discharge. 8X Pig. 4010 Scrubber - 8" Suet. 8" Discharge. 4'-0" O.D. x 5'-3". Stool eanat. Purchased fron Opelika Weldlas>Mneblna & Supply, Inc. Spec. SM-488-534. P.0, Mo. OgD-7736. Purehaeod fron Goulds Punpt, lae. 6'-6" x 7*-9" C. stool equipped with heating eoll. 5 turns 2" Sob. 80 C.S. pipe. Capacity 2,000 gallons. Goulds Modsl 3196 APS Mo. A 60 eonitnetit of Ductlla Iroo. Capacity 129 6PM. MQNS 049699 i appkhdix a - qcinT un wo ! f])7 iWHWB.9 nlp. Ho. Do. 9 Chlorlnator Mlt lllalnator ^5il Ho* 9 Chlorlnator 32-0259 Coolar /539 Ho. 2 Blow Tank Puap 19-0302 >'440 Biphenyl faad Puap (441 No. 2 Blow Tank 22-0777 * 3*2 KS43 No. 1 Blow Tank No. I Blow Tank Bmp 22-0266-02 19-0333 Paactlotlan Monsanto Brink typo daalatar In a 30" 0.0. '<' long earboa ataal tank. Borrow noaala 10" dla., 10" flaaga, with a 6" gaa outlot. Daslgnad for 30 palg at 450P. Contalna a Brink alaaant No. 244B. Capacity 323 efin at 8 palg and 230C. Inlot alat loading 2,000 wg/au.ft. Ontlat alat loading 20 ag/en.ft. Iffloloncy 991. . Carbon ataal boat exchanger S' long with 3/4" O.D. s 15 BHQ tnboa containing 184 tubes. Pour paaa boat exchanger on tuba alda. Special dealga Margcatto axpanalon joint ccnatructad of 304 88 on aholl alda of thla haat onhanger. Capaelty 1,400,000 BI0/haar. Self-prlalng, centrifugal puap (Oowlda Modal 3196 AVS-A60, 7" opaa lapollar, with a 3 BP, 1800 UM, 440 volt water, and a Crane No. 9 outslda aachanleal aaal. Coda QP-868). Capaelty 123 0IN at 29' TUN. Self-prlalng, centrifugal puap (Oowlda Modal 3196 ATS-A60, 6-1/16" opaa typo lapollar, 3 HP, 1800 MM, 440 volt ante*, and a Crana No. 9 owtalda aaohasilcal tool. Coda No. QP-868). Capacity 73 0IN at 39* TON. 7'-6" O.D. x 7'-6" atralght alda vertical tank, flat top with a dlehed bottoa. Tank contalna a 2" Seh. 80 pipe eoll approximately 73' long. Capaelty 2,300 gallona. ' Sana aa Itaa 313. Vortical, centrifugal, aubaargad Tabor puap. 2-1/2" Inlet - 1-1/2" aotlat. Cant iron construction. Capacity 30 0IM. HONS 049700 Amiran a - iqgmmt list *aA.spo 7. It-- gculpnent lsnls.Mo. -'544 Vil|k Tank Seala 24-0194 545 Crude proctor Catch Tank Transfer Tump t 544 Brink Sami*tar 41-0037 Mo. 7 Chlorlnator t-547 i/548 t 549 Brink Demister 41-0038 Mo. 4 Chlorlnator Brink D--later 41-0039 Mo. 5 Chlorlnator BC1 Off-Caa Condenser (Llguld Syst--) ,,350 Chlorine Vaporiser 32-0185 551 ,552 Ho. 1 Chlorlnator 22-0475 Mo. 8k Chlorlnator 22-0473 Description Palrbanks-Morse, Inc. overhead auapanalon acala. Nodal CA, coastal cabinet dial, having a 22" dla. chart graduated 0-24,000 pounds with a --In earn bar graduated 20,000 pounda and 5,000 po--da. The dial baa one adjuatabla Head awltoh to oparata at scale sot point. Seals to be hung balow 11' platform level built to eontain the neigh tank. Capacity 0-24,000 panda s 20 pounds Increment! for acala measure ment . Overall capacity 0-50,000 pends. Self-priming, vertical centrifugal pump (Tabar CV-3, #393, vlth a 2" auction and 1-1/2" discharge, 10" dla. z 3-1/2" I Impeller, 5 HP, 1800 HIM, 440 volt motor) Capacity 80 CM at 100' TM. l'-8" dla. x 4'-2" straight aide carbon ataal shell vlth a Brink type nsh demister pad. Same as It-- 544. Same as It-- 544. 20' I.D. s 8' long, standard Moss--to fixed tube abeet heat exchanger with 304 3/4" O.D. x 14 BH0 tubes. Ixchanger has four passes. Overall area 440 sg.ft. Capacity 132,000 BTO/hour heat removal. Armstrong chlorine Vaporiser, vertical typo, complete vifh sopor heater sectloa Mona! construction - purchased from k. M. Armstrong Co. 90 tons/day capacity. , 3'-0" dla. x 14'-0". See Drawing B-4209. See It-- 551. M0NS 049701 AFraroix a - EQoinmrr urr AHA 500 1 Itaa -353 lonlo.Mo. No. 3 Chlorlnator 22-0673 Daaarlatlan S Itaa 531, , 55A No. A Chlorlnator 22-067A Saa ItM 551. .555 No., 8 Chlorlnator Saa Itaa 551. i 556 No. 7 Chlorlnator Saa Itaa 551. - 557 No. 6 Chlorlnator 22-0677 Saa Itaa 551. -558 No. 5 Chlorlnator 22-0676 Saa Itaa 551. -559 Ho. 4 Chlorlnator 19-0A1A Saaa aa Itaa 509. - 560 561 562 -565 -566 -565 Brink Daalatar A1-00A0 No. 1 Chlorlnator Brink Daalatar A1-00A1 Ho.2 Chlorlnator Brink Daalatar A1-00A2 No. 3 Chlorlnator Brink Daalatar A1-00A3 Ho. A Chlorlnator Brink Daalatar A1-00AA Ho. 8 Chlorlnator Inatrunant Air Coa^raaaor 37-0098 Saaa aa ItM 5A. Saaa aa Itaa 5A6. Saaa aa Itaa 5A6. Saaa aa Itaa 5A6. Saaa aa Itaa 5A6. Joy Manafaetaring Coapany Mo. WNI-I, Slao 8" i 5" kld-nountad air eoapraaaar unit vltk aftar-coolar and air raoalvor. Oparatad by a 25 HP, 1800 UK, AAO volt notor. Capacity 105 efa at 100 palg. MONS 049702 appibdix a iqoiPMnrr list AyA eon 9. Ua ^3*6 3*7 Sig 3*9 370 371 </in 373 "37* ^57* SiS laaloaont Control laoa Sink and Bood SaalEjo Control loan Air Condltlanar *4-009* Atrtf <1 e>NTSdi Be. * Chlorlnator Circulating Puap 19-0*1* Be. 7 Chlarlaator 19-0*14 Clranlatlng Puap Be. 3 Chlorlaater 19-039* Clranlatlng Puap Ba. g Chlorlaater 19-0*03 Circulating Paap Ml Off-Oaa Catch 22-0111 tank (Llguld Chlorlaater Syotaa) Trappings Traaafar leap (Llgnld) Brisk Milt lliainater Ml Caeh leak lOrr** F<miThi*> Description Aat Hood lulpil by Inm-XnN Ce. #73 Gram unit with a gray eolerlltk tap. Faa la aa Aaarleaa lloaar 1-1/* D renewing 7S2 efn at 1/2 8.P., 1/3 HP, 110 wait, 1723 UH Motor. Capaelty funs reaoral 7S2 efa. Carrlar Hodel 4t DAOOg-Ml. loaf asuatod cooling an* kaatlag wait; 9S.000 BXO/hanr aoalaal eaallag) 2*0,000 BlU/haar haatlag aoalaal direct lira* aataral gaa baatar. Baaa aa Itaa 309. gaaa aa Itaa 309. Saaa ao Itaa 309. Saaa aa Itaa 309. I'-*" 4ia. a 11'-3" atrstght olio, carbaa ataal task, with 41aha4 haa4a aad a 3" Sob. go aarbaa ataal plpa aall apprcalaataly 120' laag. Capaelty 3,000 gallaaa. falf-prlalag, harlsaatal aaatrlfagal paap (Ooulde Nodal 319* ATS-A40, coaotraatad of Daatlla lroa with a 7" 41a. apaa type lapallar, 3 V, 1000 1M, 4*0 wait aotor, with a Craaa Ba. 9 outside aoabaaleal aaal, Ca4a qt-OM). Capaelty 123 OPM at 75' TIN. Moaaaats Brlak typa aalt, 2'-*" 41a. a 11' straight a14a, eaatalalag a Brlak slaaoat Assigned far.3 pslg at 10S*P. ' taaperatara. Capaelty *33 afa at 131 Ml gaa. Designed to eallaat 991 af entralaed Aroplata aad retorn to the cateh taak. MONS 049703 appendix a vjairmtrr list aha >oo xo. . Xtai S77 MrtpJo. Therainol Svr* Tank (or Solid Ml Cl*an-Dp Cond*n**r BpmUpMw 3 ' -6" dl*. n A'-3" *tral(ht *ldo, carbon (tool tank, containing * 2" Seh. SO carbon *tool coll apprexlaataly 10' long. Capacity 300 gal*. 578 Thcralnol Pimp (or Solid* Knook-<hit Condonoor SaK-prlalng, horlaontal e*ntrl(ng*l puap (Gould* Modol 3196 ATS-A60, conatructad of Duetlla Iron, with an 8" open type lapellor, driven by a 7-1/2 V, 1800 IPM, 660 volt actor, puap equipped with a Crane lo. 9 octaldc atckanleal **al, Cod* QP-868). Capacity 150 CPM at 50' TOR. l 379 Thonlnol Coolor (or Solid* Knock-Out Condonaor Syctaa Dialer Modal Mo. 2 n alr-eoolod alnalnua (lnnod tuba coolor, 3' a 3'-6N x 3*-9" high. Contain* a fan driven by a 1 HP, 1800 KPK, 660 volt BOtor. Capacity 550,000 H0/hour. , 380 Ml 0((-0* Condontor (Solid* Syataa) 2* dla. x 10'-6" long, carbon (tool beat exchanger, with 80 1-1/2" O.D. x 16 IMS x 8' long tuba* (*lx tub* pa****). Condenior contain* 230 aq.ft. urfaco area. D**lgn*d (or 150 p*lg and 160C. 381 Ml 0((-0a* Catch Tank 6' dla. x 3'-9" atralght (Ida, carbon (or Solid Syctaa 22-OtlI. ateol tank with dl*h*d head*. Tank ' 1* a jackoted carbon (tool tank dcalgnad (or 125 palg at 160C. Jacket declgnad (or 110 palg at 160C. Capacity 300 gallon*. ' 382 Hater Puap (or Liquid Areolor Kneck-Out Condonaor JUb?- f Salf-prlnlng, horliontol centrifugal puap (Gould* Modol 3196 ATS-A60, 2 x 3 - 10, with an 8" open type iapollor con*truetod of Ductile Iron with o Crane Mo. 9 out*Id* acohanleal **al, ^ Cod* QP-868, driven by a 7-1/2 IP, O 1800 1PM, 660 volt actor). Capacity 200 GPM at 75' TDM. 586 *t-0TJ6/ II T II II * r n If--*"1|d frr- *** pbUBf . HONS 069704 '----- Ammxx a iqniMnr list A1IA 300 11. Its 'Sts /Mi Iwtowfflt Chlorlnator Chari* Ink Air llowar (South) An Air llouar (Middle) laalp.Bo. 22-0787 11-0323 11-0324 Daacrlptlan 1,000 gallon ataal tank purehaaad frau Mlaaourl Bailor 6 Tank Ca. 7,0. B0. D47909. Inatallad Bor. 1939. totary poaltlro with aatandad baa* and P-drlra, Intaka filter unifier, ashaua* aufflar, T-b*lt guard, 1" praaaura rallaf nln. Turohaaad frou Sutorbllt Corp. ' Sana a* Itan 586. -388- Blpbanyl Faad Tank Agitator 11-0106 Talk 4 BUZ, Batlo 13.9 to 1. Spaa. 8K-4SS-520C. Dwg. D-488-M116. <nZto|/ / 33-0122- Spaoj. 8M-488-331- S6K Flgur* 4014, Stmat-laMiftw emlat)df)|i jfch"httt.JRXQ Mag t\sSm SexwBbar. 1-6'ijH: 4040 PMpaotfr PlbargUaa Saparater. laatruaaut Air Caupraaaar 37-0073 JOT V7T08-9, 81a* 6% a 4k, Capacity 30 SC7M at 100 palg output. Water coolad, alngl* atag* doubl* acting, carbon ring, non-lubricated, with Si3 j7cr. V-b*lt drlv*. ipec \ i/im Inatruaant Air 14-0029 Ilaetrle raganaratlra daaleoant Dryar ' dryar, neaufacturad by Trinity qulpuant Corporation. \ S1l> dU e..*.pdje CW U*j t-otroi4c O.A.pufWot z^/rert HONS 049705 loo in , toi AFIBDXX A - KfDXFMBR UST frit4;ll M IBA 600 **>![ . laulaamt Beale.Me. Deaerletlen mi onBd Task nap 19-02*3 1-1/2 MO 6 - all bronee, SAB 63 Fraaa 213 - 8arlal Me. 121340 Faarlaaa. 12. i M2 lo. 3 Bland tank 22-0067 7'-0" O.D. a approx. 7'-0" on ahall. Dvr. 9-C-8247. 0) .'04 105 606 Mo. Island 49 '<069 FU* TSec^u*f Me. 2 Bleed t * 22-0270 TMk Me. g,Blond Wntltf pnrsfTfw-v Me. 1 Heed ' . Tank 1-1/2 MO 8 - all broxaa, SAB 63 Fraaa 213 - Serial Mo. 121340-Fearleaa. Same aa Itaa 602. Saae aa Itaa 603. Same aa Itaa 602. (,607 , Me. 1 Facuua keoelvor 22-017601 Saae aa Itaa 609. *608 Me. 1 Taouua Raoalver Flap 19-0272 Flf. 3202 Mo. 90 TFt, all bronse. Furchaead froa Blaekaar Fuap Co. V 60) 22-0026 5*-6" I.D. x 5'-6" Meeal. Dug. C-793. 1 *1 si 610 > 611 Me. 2 Vacuum Receiver Flap Mo. 3 Vacuum (OMlWt 19-0271 u6U "613 Receiver Fuap (Me. 3 Still) Me. 2 Filtrate Receiver 19-0264 22-0086 8aaa aa Itaa 608 6'-6" 41a. x 7'-9" ctralght aide, vertical tank, Used wltk Monel plating. Tank equipped vltb a Monal cell cosatructed of 1-1/2" Seh. 40 Monel pipe with appro*. 48 llaaar faat of coll. Capacity 2.000 gallena. Modal GZ-CB MBNA 213. Fig. 3202, 90FFB brenae, Blaekaar Pump. 7'-0" 0.i. x 7'-0". Dug- 9C-6247. Purchaaed froa Chattanooga Bollar and Tank Co. MQNS 049706 AmMDXX A - BQDXfWMT USX mLm 13, ism isatowat "814 Mo. 1 Filtrate teeelver 615 No. 4 Still tceip.uo. 22-026} 22-0779 ` 616 Mo. 4 Still 19-050} Circulating Map > 617 might Klavator 10-0200 i418 Ho. 4 Still leatar 32-0271 ' 619 Mo. 4 Still Condenser 32-0272 Daacrtotlon Saan aa Itea 613. 7'-6" dla. x 7'-0" atralght aide, vertical carbon ataal tank with dlahad haada. Tank equipped with a heating coll conatructed of 2" Sch. 80 carbon ataal pipe with approx. 77 eg.ft. of aurfaca area. Capacity 2.500 gallaae. Self-prlalng, centrifugal, vortical puap, (Taber vortical aubmargad Mo. 345 CC-5, 12-1/2" dla. open typo lapellet, 25 MP, 1800 ITM, 440 volt actor, with a jacketed stuffing box for water cooling). Map haa a special gallaa expanalon Joint with rode and dlaeharga pipeline. Capacity 150 GIN at 120' TOM. 1,000# all ataal freight elevator with 3' x 4' platfora. Purchased frea Midvale Material Handling Zqulpmaat Co. Capacity 1,000#. Direct fired natural gaa haater with lnaulatlon and refractory lining ecoatructed by Alcorn Combustion Coapaay. 7'-ll" dla. x 11'-8" high ahall cootalnlng a 3" dla. Sch. SO coll, 259 sq.ft. aurfaca sroa In a 6' dla. circle, cater alao contalac a John Zink W No. 10 gaa burner. Capacity 355,000 HD/hour haat absorption (heat Input 550,000 NU/hour). 1'*2" dla. x 10' long, carbon ataal haat exchanger with 112-3/4" x 14 MB x S' long tubaa, designed far four passes on tuba aide. Designed for full vacuum. Condaaaar contains a special design Marquette expansion Joint constructed of 304 stainless stool with Sch. 30 welding anda. Capacity 477,000 MM/hour. MQNS 049707 appudix a - Kqoimnr list 14, lH lavlpWflt lrolp.Ha. 620 Ho. 4 Still 22-07S0 Vaeuua taceiver 621 Ho. 4 Still 19*0506 Vaeuua lacalvar Trans far Pusop 622 Tharalnol Surge 22-0761 Tank 623 Thaxalnol Clr. Fuap for Ho. 4 Still Coolant 19*0507 624 Tharalnol Cooler Ho. 4 Still Systaa 625 Ho. 4 Still Catch 22*0762 Tank Daacrlotion 6'-6" dla. x 7'-9" straight aide, carbon ataal vertical tank with disked heads. Contains a 2" Seh. 60 earbea stool coll with approxlaataly 32 St.ft. of surface area. Designed for full vaeuua operation at 400C. Capaeltp 2.000 gallons. Salf-prlalng, centrifugal puap (ConIda Modal 3196 AVS-A60, 7*7/6" dla. open type lapsliar, 10 HP, 1600 HIM, 440 volt aotor, jacketed stuffing bos for Tharalnol heat. Crane Ho. 9 outside aachanlcal seal, Code QP-666, easing of puap Jacketed for Tharalnol heat). Capacity 125 CPM at 50* TUB. 3'-6" dla. x 4'-3" straight side, carbon stool vossal with dished heads, contains a 2" Seh. 80 carbon steel cell with 7 sq.ft, surface area. Capacity 325 gallons. Salf-prlalng, centrifugal puap (Qoelds Model 3196 AV8-A60, 8-1/16" dla. open type lapallar, 7-1/2 IP, 1800 HIM, 440 volt aotor, with a Crane He. 9 outside aachanlcal seal, Coda QP-666, constructed of Ductile Iron). Capacity 100 0PM at 65' TO. Air-cooled heat exchanger, Model Ho. 58B5A48, 1" O.D. INC 16 tubes, 4' long, with alunlnua fins, 60 sq.ft, surface area. Total fin surface area 1,171 sq. ft. Overall dlaenslone 2' x 4' x 4'-6" high. Manufactured by Dialer Inglneerlng Coapany. Pan for cooler 1 IP, 1800 MM, 440 volt aotor, capacity 5.500.000 DTO/hour. 3' O.D. x 3'-9" straight side, carbon stool tank with dished heads and a 1-1/2" Sch. 80 coll 6' long. Capacity 200 gallons. HONS 049708 APFRHDIX A - KQUIPMgMT USX ABiAJOO 15 1MB H>--nt '626 Ho. 6 Still Vacuuw Jat Rculp.Ho. 35-0123 627 Tharalnol Surge 22-0763 Tank (Ms. 4 Still Cooling Syntax) 628 Thanalnol Heater 19-0508 Circulating Pump 629 Thanalnol Baatar 32-0274 631 riakar Tank 6 Agitator 22-0700 632 Baroaatrlc Snap Tank Paacrlptlon Thrae-ataga Worthington Ro. 2-1/2 JTO Jat ajactor. Flrat ataga apaolal daelgn; aacond ataga Ro. 5; and third ataga Ho. 6-A. Jat alao lneludaa a 10" I.D. porcalaln baroaatrlc lntercondanaar. 5'-O.D. x 12' atralght aIda, horlaoatal, carbon ataal tank with dlakad haada. Tank contalna a 3" Sch. 80 coll 20 long. Capacity 1,900 galIona. Salf-prlnlng, centrifugal pnap (Tabar vertical aubaerged Ho. 346-CCt, with a 12-1/2" opan typa lnpallar; 30 IP, 1800 1PM, 440 volt notor, Jackatad atufflng box for watar cooling). Capacity 350 CIM at 165* TUB. A helical tuba haatar with croaa-flow connection of the four circulation typa for hacting Thanalnol n-2 by direct firing with natural gaa, couplata with lnaulatlon and refractory lining and coll, 8'-6" dla. x 15'-6" high ahall with walla lined with 3" caatable refractory Lmlte-laydlte vemlcullte 124 nix, aultable for 2,000T aarvlca. 4" Sch. 80 coll 350* long with a total aurfaca area of 950 aq.ft. Furnace fabricated by Alcorn Conbuatlon Co. Furnace provided with a Horth Aaerlcan 6" Ho. 214-88 dual fuel burner. Capacity rated at 8,150,000 ITO/hour for tha burner. Total heat abeorbed 6,000,000 BTU/hour. 6-blade turbine typa lnpallar, 26" dla., conetructed of carbon ataal with a 3-1/2" dla. x 8 ft. long ahaft. Motet reducer la a Falk 4 EUZ apaad reducer with a 13.9:1 ratio. Slow apaad abaft, 125 RIM, driven by a 10 HP, 1800 RFM, 440 volt aotor. Capacity, provide nadlun agitation, i,, 250 gal. ataal Jackatad tk. 3' dla. x 3' long vertical tank. fabricated by Flbarglaaa. Capacity 150 gallona, HONS 049709 APPBHDIX A - EQUIPMENT USX AJJA AQO 16. XlH 634 Liaa Hopper Mo. 4 Still Eaulo.Mo. 635 Montar Conveyor 33-0055 636 Still lottoao Blower 11-0339 638 Drua Conveyor 639 Seala (Toledo) 24-0182 640 Pollahlns PiItor 641 Intralnaant 41-0045 Separator #4 Still 642 larth Ovan 14-0033 643 Bpasaod Filter 15-0029 Daicrlotlon 2' x 2' x 1' high hoppar, fabricated of carbon itoal. To fit a 6" noaala. Capacity 50 lba. of llna. 2'-0" x 20'-0" ataal roller type conveyor. Drawing D-488-Ml32. Centrifugal fan per ipeo. fM-488-636. Blower for fuaa renova1. V-balt drive and aotor aaaeably for above fan. 5 HP aotor, 440 volt, 60/CX, 3/Phaea, for chaalcal duty. 2'-6" x 10'-0" uaad at Liquid Aroclor drua-out itatlon. Modal 2881 Serial No. 4139, naad for weighing Liquid Aroclor drum. Sparkler Filter - r-9" x 3'-6" QAM. Purchaied froa Wright Auaton. F.O.Ho. 0BD-7952. 16 KW-2 door ovan with controll. Standard electric ovan. Purchased froa Daspateh Ovan Coapany. Modal 18-S-23 horlaontal plats type 304, at. w/acavunger plats feature on plpa lags. Purchased froa Sparkler Manufacturing Co. 8 alj fr-rm i Tf*ilT 63 645 Floor Cleaning 49-0537 Machine 646 Micro PuIvorliar 17-0027 Modal Mo. 204325 - Serial Ho. BP 17646. 5 BP, 220 volt, 3 phase aotor. Purchased froa C.B. Tennant. 2 DR Micro Pulveriser with discharge chut* aouneii on itml bain. Mala aotor 10 RP, 3AS0 UM. fan eonlad. Faad aotor 1/3 HP, 1723 UM. Sarlal Mo. 12184. Purchased froa hlmlali| Machinery. MQNS 049710 APPIHDU A IQUI7MUT LIST AHA 600 17 It-- lanlp--nt -650 Ho. 1 Still Pot Srateflfa. 20-0018-01 651 Circulating punp 19-0230-01 Ho. 1 Still 652 Ho. 1 Still Hoator 653 Mo. 1 Still Condenser 42-0018 32-0116 65A '655 656 - 657 658 659 ^ 660 <661 .662 .663 Ho. 1 Still E3actor 35-0105 Me. 2 Still Pot 20-0002-01 Circulating Punp 19-0240-01 Ho. 2 Still Ho. 2 Still Hoator 42-0050 Ho. 2 Still Condanaar 32-0141 Ho. 2 Still Kjactor 35-0106 Ho. 3 Still Pot 20-0052 Circulating Pump 19-0248 Ho. 3 Still Ho. 3 Still eater 42-0052 Ho. 3 Still Condanaar 6'-0" dla. x 51-6" high cloaad ataal aa par drawing C-809. Ho. 345 aaal-atl. CC-5, caatrlfngal vertical motor pun?. 3" lalat, 2-1/2" outlet. Purchaaed from Tatar Punp Co. 3'-9" 1.0. x 4'-10-1/2" ataal ahaat nada par Dug. g-886. 12" dla., 7'-6" long, 19-1-1/2" 1 Pg Sch. 40 Honal tubes. Purchaaed (re* Dovlagton Iron Works. #9 H980H001 Type 0 Carbsta IJactor. 6'-0" dla. x S'-6" high elosad stool aa par drawing C-809. Sana as Item 651. Ho Description on Pile. SaaM aa Itan 653. Sana aa Itan 654. Sana as Itan 655. Sana aa Itan 651. Ho description on Ilia. SaaM aa Itan 653. HONS 049711 aroma a -wtmmmvu 6M </669 1S70 674 *^40 M Mo. 3 Still SJootor 33-0123 Poaerlatloa 2-1/2 JM 3rd Staga. Purcbaaad frun Worthington Carp. P.0. Ho. 12034. Inatallod January 1944. Llaa Slurry Task 22-0790 Slurry Tank (or Ho. 3 Still. 10* US ataol Hyd. 4 ilaaga aaaaahly, atool intarnal parta. Ho. 1 Hoof taak 22-0071-01 S' dia. n 30' long. Capacity 11,000 gallona. Circulating Funp (Spara) 19-0231-01 Sana aa Itaai 631. Aroclor Flakar 14-0031 Modal 9MS 3-36, aiaa 24" i 40". Stalnlaaa ataol drua with (aad paaa. furehaaad Iron Ooalin. &/ f1 V '^-#'1 Ca h-d-? A.? 3f.'ll S* Sd I A *o / (c *7 HA w * 4 7/ (j> 7 ~i -3* / ^ ^^ "~d* "y MUNS 04971^ 1 co?;; iVTIAL MQNS 049713 iunu> NMnemno mocbio m mm I - HBBItt ITWfflCATWW I- Aroelor 1221 Aroelor 1222* Arcelor 12A2 M Aroelor 1244 M Areelor 1234 + izrw t Areelor 1260 M Aroelor 1262 Aroelor 12M }' Aroelor 2363 (oaAistilled) Aroelor 4463 Aroelor 5442 Aroelor 3460 -hi S,6 4 9 7 Areelor 1232 is s alxtere of apyroxlaately 52.4S Areelor 1221 tmi 46.61 Aroelor 1242 <hy ooIms). XZ *. Blyheayl h. Oeateoes 0 e. Intwn t 4. ehlorlae e. ByArstsA Llae f. Attayelfss Berth Ferrlo ChloriAe MQNS 049 714 Monsanto ICAIIONl Annliton, Ala . May 2, 1969 KUVJICT SPECIFICATION REMOVAL TO J. C. Landwehr M. B. Mullally W. B. Papagtorge H. L. Williams Authorization has bean received to cancel the following (Finished Goods) specification. Material Name Date Issued Product Code Aroclor Capacitor Fluid (Fyranol 1481) 4/18/66 1050-120-16-03/09 Please destroy your copy of this specification. Rose Hlggerson, Standard Documents Department will retain one copy for reference. G. W. Miller /be m io ncv no MOWS 049713 Monsanto AROCLOR 1221 PRODUCT epos |0C*T. ( krm. Ml FINISHED PRODUCT SPECIFICATION H46utipm 3-1-69 Anov *(. 1*48Ilc2O6O.1C0 Salaa 1040-223-04/11-009_____________________ J. jmilana 2/19/69 . M. S. Gibb* 3/12/69 OUA1.ITV CONTROL (Chief Chemist) W. Ault 3/10/69------------------------------------------------- R. Blovara 3/26/69 C. W. Millar 2/13/69 MXXTURI 4mm.. pn'uia --------- 2 x 1/2 1. Anber Bottle* G. Millar (R) Condition (R) Color, ARRA (R) SpecIfle Gravity <25/13.5*C) (R) Acidity, (M( K0H/g) (R) Vlacoalty 9 100t Clear 100 Max. 1.182-1.192 0.014 Max. 38-41 80S 4.0-5.5 Cp G-l 046 052 050 049 MQNS 049716 WtKaiM (R) Routing Analysis, All others Analysed by request Only Monsanto PRODUCT AROCLOR 1232 MMUlf 6411 I""- Aim. M ! an------ 1 MR 248 1 * PINISH1D PRODUCT SPECIFICATION PRODUCTION ABAWTItIoffifSIJ"Vt*VI"O,K 3-1-69 APPROVAL* 826.11 & 81113 Salaa miki iobi " 1040-230-06/11/003/009 j. jtollov 3/21/69 H. William* 2/19/69 M. S. Glbba 3/12/69 QUALiTV CONTROL (Chlml ChmmlmO M. Ault 3/10/69----------------------------------------------- R. Blowort 3/26/69 G. W. Mlilir 2/13/69 MOTION CHCMICAL FORMUI MIXTURB 11-17-66 6AMALI rOA ANALVAI* 2 x 1/2 gal. Aabar Bottlaa G. Millar (R) Condition (R) Color, AFHA (R) Specific Gravity, (25/13.5*0) (R) Acidity, (Mg KOH/g) (R) Vlacoalty 9 100*F Claar 50 Mas. 1.270-1.280 0.014 Max. 44-51 80S 6.5-10.0 Cp Annlaton G-l 046 052 050 049 as 10084 10084 10114 10087 10086 HONS 049717 MNillt (R) Routine Anolytit, 41! othtrs AnalyanA by rfu*4 Only 7rott teasMteottm Color, AHA 100, Hex. AcUlty, a( K0B/|. 0.014, Max. Spaelflc gravity 9 25/15.3"C 1.270-1.260 Vlieoilty 9 100*>'., 606 Uml luftnttla tChlorine, 44-31 31.3-32.5 HSfeSUfc 14-44-34 14-42-34 14-49-34 14- 4-32 14-13-34 Hatar, yya 33 Max. tafraetiva Index 0 23*C 1.6180-1.6200 Condition fill TiriwriiB Inorganic chlorldee, ffm Claar Liquid 0.10 Max. Malatlvlty, oba-ea 300V DC,0.1" (ay, 100*C. 300 x 109 Mia. Dlalaotrle Conatant 9 l KC,100*C . 4.3-4.3 Diitillatloa Baafa, *C. eorraetadi 10t, by vt. 2*), Ua. 201, by C. 310-320 Ml, by *t. 360, Has. 14-33-34 14-34-34 10-064 014 14-33-34 14-36-34 14-31-34 MONS 049718 latitn FtaliM Mtat IpNliUitln Predneti Aroelor 1232 (HitUM) ninicnD bpiciiicatiom flMWMl iBfor--tlCB - COntlOMd few Point, *C. Belov -30 Corroilon Toot Chan( la wt. alunlnua, X 0.0 Acid Ho. after toot, at KM/t* 0.013, Has. Inortanlc Chloride* after teat, P 0.10, Han. Condition after teat Clear Color after teat, APhA 100, Mas. ott/m 10/20/M .aaaoA. fa^ 2 14-47-34 14-32-34 014 6-1 14-44-34 HONS 049719 Monsanto ' MUCT . AttKXOt 12*2. HJCX1ICAL OlADt |mt. m 24* Uanlstaa UI.C M1NISHBD PRODUCT SRBCIRICATION A*fflVtW?~WCK -1QZ21/69. 81101-82612_____ Sales 1040-240-04/11716-03/09 HOWCTIM mihith------------------------------------------- 1 - -- M. g. Ault /i/ W. 8. Ault niriOM M. g. Clbb* // M. E. Gibbs 1/3/70 OVALITT CONTNOL IlflUIH 1/7/70 12/23/M_________ G. W. Minor /a/ G. W. Mlilor 10/30/69 Hiw<*b rouMwk* "" Alto known at Pyranol 1499 HT. AMk PM 4MAbVIII _________ mim_______________ HAH ACT CRltTlC 3x 5 pt. Amber Bottles \M*t% mmwm> ar<awno () Color, APHA (1) Condition (A) Specific Gravity <1 23/13.5*C (E) Acidity, a* EOB/g (l) Holatura, ppm (I) 8atractive Indax 0 23*C (I) Inorganic (free)' Chlorldaa (1) Pour Point (8) Dlalactrle Conatnnt (1000 eyclaa 0 100*C) (t) Eaalatlvlty (300 VDC 0 100JC 0.1" Gap) aa obn-cn x 10* (1) Bydrolyalc Stability Tact (as ohlorldaa) (1) Monaanto Stability Taat (aa ohlorldaa) (1) Distillation Kangs (AS2M D-20, Corrected) IM Dlstlllad by vt. 901 Dlstlllad by vt. Sulfatas Dlalactrle Strength 0 23*C Plash Point, *F Plra Point Corrotlon Toot (t hrs. 0 210*C with bright alunlnum foil) Change In wt. of Alt A.C. Color (APHA) A.C. Condition A.C. Acidity, ng KOH/g A.C. inorganic (fraa) Chlorldaa Viscosity 0 100`T. SOS 40 Max. Clear 1.381*1.392 0.010, Max. 33 Max. 1.6240-1.6260 0.03 ppm, Max. -14*C or lover 4.70-4.90 500 Min. 0.5 ppa. Max. 0.4 ppa. Max. 325*C, Min. 360*C, Max. Non* 33 KV, Min. 338-392 Nona 0.0 60 Max. Clear 0.010 Max. 0.05 ppa, Max. 82-92 G. W. Millar M|TNM m Anniston 10084 10084 10114 10087 10620 10125 12741 10113 11608 046 0-1 032 030 047 048 014 033 113 11607 121 12672 11303 10117 010 133 054 12169 11603 10123 10123 10126 12169-MGK 043 114 114 136 10084 10084 10087 12741 10086 046 0-1 030 014 049 fRtM (R) Reuil*0 Analyit, Ait etKtrt Anolynd by Only MONS 049720 CBMAfc BTOmftTKW Specific Ht 9 25*C Coefficient of ExpanaIon (2S-65*C) rixtd Chlorine Power Factor 9 100*C 60 cyctaa 1000 eyelet SFECIAL CUSTOMER REQUIREMENTS Cancral Electric Thermal Chemical Chlorldee Weatlnghouea Hydrollaable Chlorine (Hattlnihouae Stability Teat) 0.30 0.00068 cc/*C 62.5-43.5% (Typical Valuta) 5 0.30 0.65 ppm, Max. 1.0 ppm. Max. Arniltton Rfc. 113 039 -092 M0NS 049721 Monsanto ORGANIC CMCMICALl 04VIHON wwoovcr Imot. AROCLOR 1242. EXPORT GRADS ELECTRICAL GRADE 82*0* PLANT FINISHED PRODUCT SPECIFICATION nrasucTiKr- Anniston 10/21/69 APNROV AH MtllMU _IA__L_II9G2O6B.I12________ ___kin________________ 1040-240-16-009 H. L. Will Urn* // H. L. William* 11/12/69 M. E. Gibb* // M. S. Gibb* 1/8/70 ALII QUALITY CONTROL (CMel Chemiet) W. E. Ault // w. E* Ault 12/31/69 ICRINTlON G. W. MlUor // G. W. Mil lor 10/30/69 CHEMICAL NORMULA MOW WT. UMRSIDCS SNICS. ON Tentative 6/12/67 MAN ACTCRISTIC UNRESTRICTED INFORMATION IAMPLI NOR ANALYSIS 3 x 5 ot. Amber Bottle* LIMITS G. W. Miller (R) Color, APHA (R) Condition (R) Ipeolflc Gravity 9 25*C/15.5*C (R) Acidity (mf KOH/gm) (R) Nolitura, ppm (R) Rlfractlva Indax 9 2S*C (R) Inorganic (free) Chlorldaa , ppm (R) Pour Point, *C (R) Dlalactrlc Conatant 1 KC 0 100*C (R) Raalatlvlty ohm-cm 300 VDC 0 100*C, 0.1" Gap (R) Hydrolyala Stability Taat (aa chlorldaa) ppm (R) Monsanto Stability Taat (a* chlorldaa) ppm (R) Blphanyl, t (R) Dlatlllatlon Rang* (AS1M D-20, Corrected) 10T Dlatllled by wt. 90t Dlatllled by wt. Sulfate* Dielectric Strength 0 25'C Plaah Point (*F) Plra Point Vlaooalty 0 100'F (SUS) 40 Max. Clear 1.381-1.392 0.010 Max. 35 Max. 1.6240-1.6260 0.05 Max. -14 or lower 4.70-4.90 5,000 x 109 Min. 0.5 Max. 0.4 Max. 0.05 Max. 325*C Min. 360*C Max. Non* 35 KV Min. 338-392 Non* to Boll 82-92 mniCTED INFORMATION Power Factor 0 100'C 60 cycle* 1000 cyclaa Report Report Typical Value* 0.30 - 0.50 0.08 - 0.10 MIT MM 046 G-l 052 050 047 04S 045 053 113 121 010 133 100 054 12169 (WGK) 043 114 114 049 113 MONS 049722 (R) Routine Analysis, All othtrt Analysed by request Only Monsanto OftOANIC CHtMlCAL* DtVIllOM FINISHED PRODUCT SPECIFICATION PRODUCTION J. Mollov 3/21/69 ilLII W. Ault 3/10/69 H. WllllanS PNoouer AROCLOR 1242 NOH-ELECTRICAL GRABS PROBUST CODE |WT-Ai. 608 J____ WE 246 Anniston A HUE 82612-81101 Sftltfl___ ____ 3-1-69 1040-240-04/11/009-003________________ 2/19/69 Kli4AnH ' " M. E. Gibbs 3/12/69 QUALITY eONTAOL (CMei Chemist) R. Blowers 3/26/69 G. Millar 2/13/69 " MIXTURE MOL WT. 9/25/67 SAMPLE POP ANALV I* [2 x 1/2 gal. Aabir Bottles C. Miller (R) Condition (R) Color, AFHA (R) Spoelfle Gravity (23/15.5*C) (R) Acidity, (ns KOH/g) (R) Moisture, ppn (R) Viscosity 0 100*7 Flash Folnt, *F Firs Folnt, *F Clssr 100 Max. 1.381-1.392 0.010 Max. SO Max. 82-92 SUB 22-26 Cp 338 Min. Nona to Bolling NCR G-l 10084 046 10084 052 10114 050 10087 047 10620 049 10086 114 10123 114 10123 9IMN (H) Routine Analyst*, All ethers Analysed by request Only MONS 049723 Monsanto ORGANIC CMtMItALt 04V*N FINISHED PRODUCT SPECIFICATION PRODUCTION J. MoIIoy 3/21/69 fflir W. Ault 3/10/69 UPTIOn H. Vllllaaa PRODUCT jaawa*[AROCLOR 1246 Wfaf wHwimuWCK --L^ 1040-260-04/11/009-003 2/19/69 MltAAdn---------------------------------------------- -- M. E. Gibb* 3/12/69 quality control (Chlsl Chemist) R. Blowtrs 3/26/69 6. Millar 2/IS/69 CHCMIi MIXTURE MOL WT. U2ML. AMP L( POP 4N4UVIK 2 x 1/2 gal. Amb*r Bottle* Itiuco V G. Millar (R) Condition (R) Color, APHA (R) 8p*clfle Cravlty, (65/15.5*C) (R) Acidity, (or KOH/g) (R) Molatura, ppn (R) Vlacoalty, <* 130*F Hath Point, *? Fir* Point, *F Clear 100 Max. 1.405-1.415 0.010 Max. 50 Max. 73-80 SOS 19.5-22.5 Cp 370 Min. Non* to Bolling Anaiittea G-l 046 052 050 047 049 m 10084 10084 10114 10087 10620 10086 114 10123 114 10123 MONS 049724 WON* CM (R) Routine Analysis, All othert Analysed by request Only Monsanto OSSANIC CMtMICAkft OIV19ION WGK end Anniston Plants FINISHED PRODUCT Q SPECIFICATION MMUSTION P, , Heisier Ulll W. E. Ault ItATtO** sseevsr 1498) locei, >4A urrjt Aroclor 1248 Electrical Grade(Pyranol j 27 Ann 811.02 Sales 5/10/67 APPROVALI 1040-260-04/11/16-03/09 N, F. Mueller W.QUAblTV COMtAOb roA*< c*mu0 C.L W. J. Gresham CMCMIC Ab rOMMUWA Miller 1 Mixture tusintsoM isces. or 1/10/64 U 2/16/64 ampis ree AMAbVtlf 3x5 pt. Amber Bottles MAftAT*MTtC LIMIT* UNRESTRICTED INFORMATION liAWCS V----- ' """ L. E. Hornback MSTMSS WGK Anniston (R) Color, APHA (R) Condition (R) Sp. Gr. @65. 15. 5*C (R> Acidity (mg. KOH/gm.) (R) Moisture (R) Refractive Index @25 c. (R) Inorganics (Free) Chlorides ' (R) Pour Point (R) Dielectric Constant (1000 cycles @100* C.) 50, max. Clear 1.405 - 1.415 0. 010, max, 35 ppm., max. 1.6285 - 1.6305 0. 05 ppm., max. 0 C., max. 4.5 - 4.7 (R) Resistivity 500, min. (500 VDC @100*C. .0. 1" GAP) as OHM-CM x 10' (R) Hydrolysis Stability Test (as Chlorides) 1. 0 ppm. , max. (R) Monsanto Stability Test (as Chlorides) 0. 5 ppm., max, , W Distillation Range (ASTM D-20. Corrected) 10% Distilled by Wt. 345*C., min. 90% Distilled by Wt. 385*C., max. 10,084 10,084 10,114 10,087 10,620 10, 125 T-2092 10,115 11,608 11,607 14-44-54 G-l 14-49-54 14-42-54 14-53-54 14-34-54 014 14-27-54 14-36-54 14-35-57 T-2087 11,503 10,117 010 14-61-57 14-31-S4 Sulfates None 12,169 Dielectric Strength @25*C. 35 KV, min. 11,605 14-28-54 Fire Point None to boiling point 10,123 14-28-54 Viscosity @54. 4`C. (SUS) 73 - 80 Corrosion Test (6 hrs. @210*C. with bright 10,086 10, 126 14-4-52 14-55-57 aluminum foil) MUNS 049725 Change in wt, of A1 (%) 0.0 A. C. Color, APHA 60, max. A. C. Condition Clear A. C. Acidity (mg. KOH/g.) 0,010, max. r A. C, Inorganic (Free) Chlorides 0, 05 ppm., max. 10,084 10,084 10,087 10,118 14-44-54 G-l 14-42-54 010 ` GENERAL INFORMATION Specific Heat @25'C. Fixed Chlorine (A) Aautlnt Anmly$l, Alt *tAr 4iiafyi^ by 0.27 47. S - 48. 5% Only Monsanto OAOANIC CHIMICALS DIVISION FINISHED PRODUCT SPECIFICATION PRODUCTION J. W. Mollov tALB! W. I. Ault ANOOWCT Aroclor 1254 ^iwisuffs1sMCrad* |aior. W-V WOK nd Ann. wi wmm n/4/w APPROVAL! HIIUtM hll. 1040-280-04/11/16-03/Q9 R. W, Bucknall OUALIT V CONTROL (ChM Ch*mlt) W. J. Cresham G. V. Mlllor Alio called Pyrinol 1476 6/28/65 AMPbt POP ANACVIK t!!URO V 3 x 5 et. Amber Bottles____ E. McEntlra/G. Stita* LIMIT! MCTMOO UNRESTRICTED INFORMATION (R) Color. AFHA (R) Condition <*) Sp. Gr. 0 65/15.S'C (R> Acidity (mg. XOH/gn.) 00 Moliturc (H,0) (R) Refractive Index 0 25'C (R) Inorganic (Free) Chloride* (R) Four Point (R) Dielectric Conatant (1000 cycle* 9 100'C) (R) Reeletlvlty (500 VDC 9 100*C 0.1 " GAP) aa 0HM-CM x 109 (R) Hydrolyile Stability Teat (aa Chloride*) (R) Monaanto Stability Teat (aa Chloride*) (R) Distillation Ranga (ASTM D-20, Corrected) 10% Distilled by Wt. 501 Dl.tilled by Ht. 90% Dlatlllad by Wt. Sulfates Dlalactrlc Strength 9 25*C Filth Point Flra Point Vise. 0 210*F (SUS) Corrosion Teat (6 hr*. 0 210*C with bright alunlnum foil) Change in wt. of A1 (%) A. C. Color, AFHA A, C. Condition A. C. Acidity (mg. KOH/g.) A, C. Inorganic (free) 50. Max. Clear 1.495 - 1.505 0.010, Max. 35 ppn, Max. 1.6370 1.6390 0.05 ppn., Max. 7 - 12 *C 4.15 - 4.35 500, Min. WGK 10084 10084 10114 10087 10620 10125 12741 10115 11608 11607 1.0 ppm., Max. 12672 0.5 ppm., Max. 11503 10117 366 - 378*C 371 - 383*C 379 - 394*C Nona 35KV, Min. Nona Nona 44-48 12169 11605 10123 10123 10086 10126 0.0 60, Max. Claar 0.010, Max. 005 ppna p Max. HONS 049726 10084 10084 10087 10118 Ann. 14-44-54 G-l 14-49-54 14-42-54 14-53-54 14-34-54 014 14-27-54 14-36-54 14-35-57 010 14-61-57 14-31-54 043 14-28-54 14-28-34 14-4-52 14-55-57 14-44-54 G-l 14-42-54 010 NIN'IN (H) Routlnt Anolytit, All o(Afi Anolyted by request Only Monsanto OMOANIC CHKMICAUI OfVlUON PRODUCT u, AROCLOR 1254 DON-ELECTRICAL GRADE FrooucTcooI------------------ [*'T'Ai. MR 1 UBK 247 FINISHED PRODUCT SPECIFICATION M66uc4ion Annlaton & HGK 82613*81103_____ _____ 3-1-69 APPROVAL* "KUtkTSrM 1040-280-04/11/009-003__________________ ------ J. Mollov 3/21/69 H. WillUrn* 2/19/69 *THf ' M, E. Gibbs 3/12/69 quality CONTROL (Chiet Chemist) Wt AvU J/19/M----------------------------------------------- R. Blowtr. 3/26/69 G. HtUor 2/15/69 mixture mol wt. 9/25/67 CHARACTCRISTIC SAMRLC FOR ANALYSIS 2 x 1/2 Ml. Amber Bottle* G. Millar (R) Condition (R) Color, APHA (R) Specific Gravity (65/15.5*0 (R) Acidity (mg XOH/g.) (R) Molatura, ppm (R) VUeoalty 9 210*7 Flaah Point Clear 100 Max. 1.495-1.505 0.010 Max. 50 Max. 44-48 SUS 7.5-10 Cp Nona *nJUvm G-l 046 052 050 047 049 WCK 10084 10084 10114 10087 10620 10086 114 10123 (R) Routine Analysis, All others Analysed by request Only MQNS 049727 Monsanto OHOANIC CMSMtCALI DIVISION FINISHED PRODUCT SPECIFICATION MAfcui+iON R, 0. Moody/a/R. G. Moody 3/23/67 ULII W. B. Ault/i/W. E. Ault 3/17/67 temPTION pnoouct Sxport Credo Aroclor 1234 Electrical Credo___ ... 127*L 126.13____________ Silu_____ 3/23/67 1040*280-16-009 L. R. Stark/s/L. R. Stark 3/21/67 QUALITY CONTROL (C*ft 5. U. Mlller/a/G. H. Miller 2/23/67 C HIMIC AL FORMULA Mixtun MOL WT< lAMPbl FOR ANAbVSIS Tentative 4/27/66_______________ tna 9 ot Amber bottles 6 HAH ACT BN 1ST 1C LIMITS UNRESTRICTED INFORMATION J. A. Llddle 2/21/67 MBYMQQ (R) Color, APHA (R) Condition (R) Specific Gravity 9 65/15.5 c (R) Acidity (os KOR/ga.) (R) Moisture (H2O), ppm (R) Refrectlve Index 9 25*C (R) Inorganic (frea) Chlorides ppm (R) Pour Point, *C (R) Dielectric Constant 1000 Cycles 9 100*C (R) Resistivity ohm-cm 500 VDC 9 100*C, 0.1" Gap (R) Hydrolysis Stability Test as chlorides, ppm (R) Monsanto Stability Test as chlorides, ppm (R) Distillation Range, ASW D- 20, corrected 10% Distilled by vt. 50% Distilled by vt. 90% Distilled by vt. (R) Biphenyl, % Sulfates Dielectric Strength 9 25*C Flash Point Fire Point Viscosity 9 210*F (SUS) Corrosion Teat 6 hours 9 210*C with bright alumina* foil Change In vt. of A1 (X) AsC# Colort APHA A.C. Condition A.C. Acidity (mg. KOH/g.) A eC a Inorganic (fraa) chlorides, ppm 50 Max. Claar 1.495 - 1.505 0.010 Max. 35 Max. 1.6370 - 1.6390 0.05 Max. 7 - 12 4.15 - 4.35 . 10,000 x 10' Min. 1.0 Max. 0.5 Max. 366 - 378*C 371 - 383*C 379 - 394*C 0.025 Max. None 35 KV, Min. None to Boll Nona to Boil 44 - 48 0.0 60 Max. Clear 0.010 Max. 0.05 Max. 046 0-1 052 050 047 048 045 053 113 121 010 133 054 100 043 114 114 049 HONS 049728 046 G-l 050 045 REamiCtED INFORMATION Povar Factor 9 100'C & 60 Cycles Report OH-IM (R) Reulint Analyaia, Alt otkara Anotyaad by rifulft Only 113 . _ " Monsanto OAOANIC CMKMICACB OlVlilOM ^CAnT ttocu "''WGK 246 euai ai------ 1 Anntitan Utt FINISHEO PRODUCT SPECIFICATION AAODUCTIOM dwrtfflh-;W; GK nnfflM11 JiilL ____ 10/21/6? 1040-290-04/11/16-03-0? A1446VAC* h1 ~ -- --...... -- JJ^L. Williams // H. L. Ullllimi 1/12/70 M. E. Glfabfl // M. E. Gibbs 1/14/70 OUAC.TY CONTAOC (ChfIChemfO R# u. Blown 1/7/70 W- R- Atilt /./ W. E. Ault 12/23/69__________ G. W. Millar /a/ G. W, Millar 10/30/69_________ CMC MIC AC POAMVCA MOW Ml! 5/25/66 CHAAACTCAI9TIC 3 x 5 pt. Atnbir Bottln UNRESTRICTED INFORMATION (R) Color, APHA (R) Condition (R) Specific Gravity 9 90/15.5'C (R) Acidity, mg KOH/g (R) Moll tun, ppm (R) Viicoaity 9 210*F, SUS (R) Rilractlvi Index 9 25*C (R) Inorganic (fraa) Chloridu (R) Pour Point, *C (R) Dlatlllatlon Rang! (ASTM D-20, Corrected) 101 Dietlllid by wt. 50* Dietlllid by wt. 90S Dietlllid by wt. (R) Corroilon Teat (6 hre. 9 210*C with bright aluminum foil) (R) Change In weight of A1 (R) A.C. Color, APHA (R) A.C. Condition (R) A.C. Acidity, mg KOH/g (R) A.C. Inorganic (free) Chloride* Flaih Point Fire Point Fixtd Chlorina, X (R) Dielectric Strength 9 50*C (R) Reelatlvlty (500 VDC 9 100*C 0.1" gap aa ohm-cm x 10') (R) Dielectric Conatant 1000 eyelei, 100*C RESTRICTED INFORMATION (R) Monaanco Stability Teat (as chloridaa in ppm) 150 Max. Clear 1.555-1.566 0.014 Max. 35 Max. 72-78 1.6455-1.6470 0.05 ppm, Max. 25-34 385-398`C 390-404*C 400-420*C 0.0 ISO Max. Clear 0.014 Max. 0.05 ppm, Max. None Nona 59.5-60.5 30 KV, Min. 500 Min. 3.6-3.8 0.7 Max. G. W. Hlllir WGK 10084 10084 10114 10087 10620 10086 10125 10118 10115 10117 Annleton 046 C-l 052 050 047 049 048 045 053 054 10126 136 10084 10084 10087 10118 10123 10123 10088 11605 11607 11607 MONS 049729 11503 046 G-l 050 014 114 114 043 121 113 133 tRtlN (R) Routine Analysis, All others Analysed by request Only o M MHUUttClttilUL Commot OMMie eNmau mvimon PiniVnftU rnwDUbi SPECIFICATION PKOWCT (IMP MW7 A10CL01 1260 tttOucT fflwnSeJc-ctr"TM MftMAL NNMH.* KUTUU r--Mf mm iM.. _ , 62614 Aniitoi v*sm* 'lEHto V. 0. Mill COOt 1040-290-04/11 /16/-03/09 Ilectrleal Grad* TTPt mom rr (U Plant Touiinnuiisr imigm uhuhiw MPia POO AMALTfil ----------------ti ct wan Salea Prooartv ODoclilcatlon Color (AHA) Condition Ifoelfle Gravity 0 90/13.3*C AeUlty (ag KOM/g.) Molatare (HgO) (ppa.) yuooaity uo*r (am) 2atractive Indan 9 23*C Inorganic (Fraa) ChlorUaa Four Point (*C) Dlatlllatloa lango (ASIM 0-10, Corrected) 10X Dlatlilad by vt. 30X Dlatlilad by we. Ml Dlatlilad by wt. Corroaloo Teat (A bra. 9 210*0 with bright alimlaun fell) Cbasgo la weight of A1 (X) A.C. Color (AHA) A.C. Coadltloa A.C. AeUlty (ag.IOI/g.) A.C. loorgaalc (Tree) ChlorUaa 130, Man. Clear 1.333-1.360 0.01A, Nan. 33, Mon. 72-78 1.6433-1-6470 Ho datoctahlo ant. 23-34 38S-390*C 390-404*C 400-420*C 0.0 ISO, Han. Clear 0.014, Man. Ho detectable cat. General Tecta (nada onlv oa racuaat) riaah Point lire Point Plgod Chlorine (X) Dielectric gtrength 9 30*C laeUtlvity (300 79C 100'C 0.1" gap ac oharcn. m 10) Dielectric Coaaeaat 1000 cyclaa, 100*c Hona Hone 39.3-60.3 30 X.T., Mia. 300, MU. 3.6-3.8 totMJn. WK lamlmtam 10,084 10,084 10.1U 10,087 10.610 10,086 10,123 10,118 10.113 10,117 14-44-34' 14-49-34 14-42-34 14-33-34 14- 4-3* 14-34-34 14-40-37 14-47-34 14-32-34 10,126 14-33-37 10,084 10,084 10,087 10.110 14-44-34 aw.aa. 14-42-34 14-40-97 10,123 10,123 10,080 11,603 11,607 14-20-34 14-20-34 14-13-34 14-33-97 11,600 14-36-43 HONS 049730 it1--4) 1 taatrlctad ltfwtlM Neaaaata Stability Tat (la Cklorldaa la pya.) flamaral Infarmatlon vaparatlon Loaa aftar 0 hra. 100'C (X) Stability taat - aftar 30 dajra at 100*e la |laaa aaalaO la air 0.7, ll.MS 14-01-57 0.2, an. 10,110 14-92-94 lo llbaratlaa af ehlarlaa ar cklarldaa ' tatyyadi Harok 7, IMS MOWS 049731 Monsanto """" AROCLOR 1260 NPORHU-UECLEf <C0T5R1ICAL SIAM 1 JOS|*,T'Ann. MB* ana FINISHID PRODUCT AfWiftPO A WGK B1VIIPPISVIUI 82614-81103_______Jftlu_____________ specification PQOOVC^ON ______3-1-69__________ 1040-290-04/11/009-003_________________________ APPROVALS jl^ Mollov 3/21/69 H. Wllllana 2/19/69 M. E. Gibb* 3/12/69 QUALITY CONTROL (ChlrnldhemlmO H. Ault 3/10/69---------------------------------------------- R. Bloptr. 3/26/69 C. Mlll.r 2/13/49 HPT ION CWMICAL PQWMULA MIXTURE MOL WT. 9/15/.67............... 2x1/2 aal. Amber Bottle* LIMITS G. Millar MTMSO (R) Condition (R) Color, APHA (R) Specific Gravity (90/13.5*0) (R) Aeldlty, (mg XOH/g.) (R) Molstura, ppm (R) Vlaeoalty 8 210*F Ploah Point Clear 150 Max. 1.355-1.566 0.014 Max. 50 Max. 72-78 80S 20-24 Cp Non* Annieton C-l 046 052 050 047 049 WCK 10084 10084 10114 10087 10620 10086 114 10123 MONS 049732 . (R) Routine Analysis, All others Analysed by request Only `t Monsanto OROANIC ChCMICAWC OlVlIION P1.ANT prmuct caai |*,'T-W. 20* FINISHED PRODUCT SPECIFICATION Anniston & WGK 82615 & 811Q7 AWSO COOS _______ 3-l-Q 1040-/300/04/11/-009/003_____________ PRODUCTION HIUAMh "" ------- - ^ll 3/21/69 H. Wllllnaa 2/19/69 M. X. Gibbs 3/12/69 QUAL.ITV CONTNOV (Chtmt ChemleO W. Ault 3/10/63------------------------------------- R. Blowara 3/26/69 G. Millar 2/13/69 IIPTION CMCMIC At. FORMULA MIXTURE MOW *T. IuRr lAMPbi JO* ANAWV 2 1/2 Ml. Aabar Bottlaa C. Millar (R) Condition (R) Color, APHA (R) Spaelflc Gravity (90/15.5*0 (R) Acidity (mg XOH/g) (R) Vlaeoalty 0 210*F Claar 150 Max. 1.572-1.583 0.01A Max. 66-100 SUS 26-33 Cp Anntft?B G-l 046 052 030 049 SS& 10084 10084 10114 10087 10086 HONS 049733 (R) Routine Analysis, AU others Anolysed by request Only M Monsanto > 00# AMIS CHSMICAlI DIVISION ' 'V ANWl4TdN AND ItkuMM&ICH FINISHED PRODUCT SPECIFICATION N W. E. Ault Quality control ICMaI 6samIaO q g Dolin W. J. Gresham `' CMOMICAL FORMULA MOL BT. 1/24/62 OMAAACTORIATIC l*HPb PM ANAkTlII 2 x 16 o*. W.M. Bottles LIMIT UNRESTRICTED INFORMATION <R) Appea ranee (R) Color (R) Specific Gravity @ 90/15. 5*C. Viscous liquid APHA 150, max. 1.572 - 1.583 (R) Acid No. (mg. KOH/g.) (R) Viscosity @ 210*F. 0.014, max. 86 - 100 SUS GENERAL INFORMATION Pour Point (ASTM) 35 - 3B*C. Distilling Range 390 - 425*C. Total Chlorine 61.5 - 62.5% Specific Gravity Temperature Coefficient (85 - 130*C.) 0. 001/C. J. P. Prader MBTMOg 10084 10084 10114 10087 A- <. 10086 | V, , . O (RJ Routine Analytit, All othnrt Anolyud by Only HONS 049734 Monsanto QRQAN1C CHCMICAtS OJVttlON FINISHED PRODUCT SPECIFICATION PRODUCT PLANT 1P/21/6? AROCLOR 1268 '1pPrloo6duvct ebb'd"1 an------- lunui _Slid. 1040-340-04-009 J31AL. PRODUCTION H. L. William. /./ H. L. William* 11/3/69 AIM W. E. Ault /a/ W. E. Ault 12/31/69 M. E. Glbba /a/ M. E. Glbba 1/15/70 QUALITY CONTROL (CMet ChemleO G. W. Millar /a/ G. W. Millar 10/30/69 MIXTURE 3/11/61 CHAR AC T AM It TIC UNRESTRICTED INFORMATION (R) Appearance and color Color, Gardnar (R) Hold Point, *C (R) Acid No., mg KOH/g AMPLC AON ANALVCIA l x 16 o*. Can or V.H. Bottla G. V. Millar White to off-white powder 6 Max. 150-170 0.05 Max. G-l 119 116 RMTRICTRD INFORMATION Scraan Teat, l retained on No. 16 aaah Mo. 20 noth Specific Gravity 9 25/25'C., Pycnometer Loaa 9 163'C., X 0.01 Max. 10 Max. 1.604-1.811 0.15-0.24 120 MQNS 049735 N.tM (H) Routing Analysis, Alt others Anolyted by request Only Monsanto OROANIC CHCMICAlt OtVttlON PRODUCT , AROCLO Mmoi4&uaIt cook 1|OtPT. 826.oa . FINISHED PRODUCT SPECIFICATION PRODUCTION y. J.. Wlllleme /e/ H. L. Wllllem. 6AfAYnTnfireIFCfo*Vn * ___ 10/21/69 AAANOV ALA _Sa1ai_________________ 1040-140-04-03/09_______________________ 11/3/69 M. E. Gibb. /./ M. E. Glbbe 1/14/70 QUALITY CONTROL (Chief Chemiet) W. E. AulC // W. E. Ault 12/31/69__________ C. W, Miller /./ G. W. Miller 10/30/69 HAT ION CHKMICAL TOAUVL A MIXTURE MOL ITT lAMPkl FOR ANALYSIS __________ /U/55_______________ 2 x 16 oz. W. M. BoCClee Char act eristic LIMIT* UNRESTRICTED INFORMATION (R) Appearance Oily liquid (R) Color Brown to black (R) Specific GravlCy 9 65/15.5 c 1.410-1.420 (R) Acid Nunber, ng KOH/g 0.7 Mex. G. W. Hiller MOTMOO G-l G-l 052 050 RESTRICTED INFORMATION Acid Number of Che crude which la ecored In non-lecquered mecel conCelnere ihell be 0.2 mg KOH/g., Mex. MONS 049736 WO M* CM (R) Routine Analysis, All others Analysed by reguest Only Monsanto oaOANIC CHCMICALl oiviiion FINISHED PRODUCT SPECIFICATION TlTnT AROCLOR Anniston till INUIIVI nrtran--------- Mil 10/21/69 1040-160-04-03/09 lft66u6TION H. L. Wllllana 1*1 H. L. Will Ians 11/3/69 unr-' " W. B. Ault // W. E. Ault 12/31/69 IIATION M. E. Gibbs 1*1 M. E. Gibbs 1/14/70 0UAI.ITV CONTROL (ChUt ChtnisO G. W. Millar // G. W. Millar 10/30/69 CHKMICAU AOAMULA MOL WT. MIXTURE warn________________ ________________________ 1 at. Bottla LIMITS UNRESTRICTED INFORMATION (R) Appaarancs and Color (R) Spaclflc Gravity 9 65*/15.5*C (R) Acid Nuobar, rag KOH/g Brown to black viscous liquid 1.500-1.510 0.7 Max. G. W. Millar MKTMOO C-l 052 050 HONS 049737 (R) Routing Analysis, All others Analysed by request Only Monsanto OROAMIC CHtMICALS OtVUtOH RROOUCT AROCLOR 1160 CRUDR PPOOUCT COO* , lotST. I 826.08 FINISHED PRODUCT SPECIFICATION ________ 646.14___________ _____ kill_______________________ _____ 10/21/69 _____ 1040-170-04"03/04_____________________ APPROVALS AIIIAAch " y. J,. William. // H. L. HU lira* 11/3/69 M. 8. Gibb* /./ M. E. Gibb* 1/14/70 OUALITV eowTROL /CM*/ CkaraUfJ W. E. Ault // W. E. Ault 12/31/69___________ KNCRAL PiSCRIPTION W,_MUl*r // G, W. Mlllr 10/30/69__________ CHSMIC AL PQBMVLA SUPtRStDCS SPKCS. OP IAMPLI * ____________3/14/65________________ 1 nt. Can______________ LIMITS G. H. Miller______________________ MRTMPO UNRESTRICTED INFORMATION (R) Appearance and Color (R) Specific Gravity <? 90V15.5*C (R) Acid Number, mg KOH/g Brown to black viscous sticky mass 1.558-1.569 0.7 Max. G-l 052 050 HONS 049738 .m (R) Routine Analysis, AH others Analysed by request Only Monsanto OftOANIC CHEMICALS DIVISION PRODUCT PLAN* AROCLOPaRO1D1UC6T2 CRUDE CODS |dpt. 1 826.06 . FINISHED PRODUCT SPECIFICATION PRODUCTION ...10/21/69 APPROVAL* hi'kkiffib'H Sal**_______ 1040-170-04-03/09_______________________ -- 11 -- --1 H. L. W1UUni /*/ H, L, William*.. 11/3/69 At* M. E. Gibb* // H. E. Gibb* 1/14/70 QUALITY CONTROL (CMmf CA*m<*<) W. K. Ault /*/ W. E. Ault 12/31/69 it DESCRIPTION G. W. Miller // G. W. Miller 10/30/69 CHEMICAL FORMULA MIXTURE 1/24/62__________________ CHARACTERISTIC UNRESTRICTED INFORMATION (R) Appearance (R) Color (R) Specific Gravity @ 90/15.5*C (R) Acid Ho., mg KOH/g 1 pt. Can LIMITS Vlacoua liquid Brown to black 1.577-1.587 0.7 Max. G. W. Miller METHOD G-l 0-1 052 050 -RK.SM (R) Routine Analysis, All others Anolyted by request Only MGNS 049739 Monsanto OftOANIC CHKMieALl DIVISION PRODUCT AROCLOR 1168 CRUDE PftoOgCt 601------------------ JoCPf. 1 826.09 FINISHED PRODUCT SPECIFICATION PRODUCTION Anniston BATK IIIICTIVI 10/21/69 ARRROV A LI hocAAiH Solos JTlTTCOOI---------------------------------- ------------- ------ 1040-210-04-09 " 1 ................"TM H. L. William. // H. L. Wllllama 11/3/69 IVlm H. E. Gibbi /./ M. E. Glbbi 1/14/70 QUALITY CONTROL (Chill Chemlet) H. E. Ault // W. E. Ault 12/31/69___________ S. W. Miller // G. W. Miller 10/30/69 IIITION CHEMICAL FORMULA MIXTURE aWF.MB.B.t VP.ca. OW 4/25/61 C HAM AC T..IITIC UHKSmCTBP INFORMATION (R) Hold Point, `C (R) Appearance and color iivio ly-" 1 x 16 ox. can or W.M. Bottlel G. W. Hitler 155-175 Black aolld 119 G-l HONS 049740 MNilM (R) Routine Analysis, All others Analysed by request Only Monsanto OROANIC CHI MIC Alt DIVISION product 2565 un-- FINISHED PRODUCT SPECIFICATION PRODUCTION B26.18 IaiCnIFrwe0H5l -------------- JlllL 13-11-66 1060-390-04-009 HHOVALS WIHAIHh ........ ' 1-- R. G. Moodv // 12-29-65 iM.ll L. R. Stark // 3-8-66 DUALITY CONTROL (ChM Chemist) W. 1. Ault /.iLLLM------------------------------------------ 3. E. Dolln // 12-29-65 CMC MIC At. rOAUWkA OIPT. ILL. " Mixture ' "".. AMRLC POR ANALYSIS IISSUCO V 4-25.61___________________________ 1 x 16 o. Can or W.M. Bottla J. A. Llddle 11-30-63 C MAR ACT CRIST 1C LIMITS MCTMOO UNRESTRICTED INFORMATION (R) Appearance and Color (R) Softanlng Point, *C (R) Acid No., a* KOH/g Black, brittle realn 66 - 72 1.4 Max. G-l 113 116 MONS 049741 ,(R) Routine Analysis, All others Analysed by request Only Monsanto OROANIC CHlMICAkl OfVIHON PRODUCT AR0CL0R 4065________ PRODUCT CODS ]0tPT. 1 826.17 FINISHED PRODUCT Ann1*ton _____ 626.19_______ Solos__ SPECIFICATION 10/21/69 APPROVAL* 1040-410-04-009 production H. L. William* // H. L. William* 11/3/69 4 ALES M. E. Gibb* // M. E. Glbba 1/13/70 QUALITY CONTROL (Chlt ChmfO W. I. Ault /*/ w. E. Ault 12/31/69 IIPTIOM G. W. Miller // G, W. Miller 10/30/69 CMC MIC AL FORMULA MIXTURE MOL WT. auoftiut man CHAft ACTCnilTIC lAMPLt FOR AMALTIII ItlUtD V 1 x 16 oz. Con or W.M. Bottle G. W. Millar UNRESTRICTED INFORMATION (R) Appaaranc* and Color (R) Softening Point, C (R) Aeld No., mg XOH/g Black, brittle realn 66 - 72 1.4 Max. G-l 113 116 MONS 049742 (R) Routine Analysis, All others Analysed by request Only Monsanto OROANIC CHEMICAL! OlVIStON PRODUCT Aunrrng __________ MooliCf 0661 JotPT. 1 R2&.I7 . FINISHED PRODUCT SPECIFICATION PRODUCTION Anniston oat* crflCTtVI -------- 10/21/69 APPROVALS 826.19 SALKS COO* _____ 8lii________________________ 1040-430-04-009 H. L. WillIans // H. L. WillIans 11/3/69 ALBS M. E, Gibbs /s/ M. E. Gibbs 1/15/70 QUALITY CONTROL (Chief Chemist) W. R. Ault /s/ W. E, Ault 12/31/69 IIPTION G. W. Miller It! G. W. Miller 10/30/69 CHEMICAL FORMULA MIXTURE UPCRSCOBS SPKCS. OP ____________ 3/11/66 [iUubo v 1 x 16 ox. Can or W.M. Bottle G. W. Miller UNRESTRICTED INFORMATION (R) Appearance and Color (R) Color, NPA, Molten (R) Softening Point, *C Acid No., mg KOH/g Clear, light yellow resin 2 Max. 60-66 0.05 Max. C-l G-4 115 116 MQNS 049743 wo m ssa (R) Routine Analysis, All others Analysed by request Only Monsanto OMOANIC CHCMICAW* PIVItlON FINISHED PRODUCT SPECIFICATION proouct PLANT AROCLOR 5042 |0t*T. 1 M.17 Anniston OATS eMMVIVI 826.21 All* coos Salts 10/21/69 1040-440-04-009 PRODUCTION H. L. Williams /a/ H. L. Williams 11/3/69 Awn W. E. Ault // W. E. Ault 12/31/69 NCRAl DESCRIPTION RISC AN6 H M. E. Gibbs /a/ K. E. Gibbs 1/13/70 QUALITY CONTROL (Chiel ChemleO G. W. Miller /$/ G. W. Miller 10/30/69 CHEMICAL FORMULA MOW WT. MIXTURE ___________ 3/15/88_______________ 1 x 16 os. Can or W.M. Bottle G. W. Miller CHARACTERISTIC LIMITS MTNM UMRE8TRICTEP INFORMATION (R) Appearance and Color Black, sticky resin G-l (R) Softening Point, C 50 - 56 115 (R) Acid No., mg KOH/g 1.4 Max. 116 I I t Ire: (R) Routine Analysis, All ethers Analyted by reeuest Only ' MOMS 049744 Monsanto OftOANK CHCMICAW* OrVlAlOM PROOuCT PLANT AROCMLfOtQRftuC5T44C2Bt--------- |PT. * 2.i7 FINISHED PRODUCT SPECIFICATION HUbuettoN oatA| lnlrnfilsCtoTnlil ___826,21________Still___________ --iflZa/fr?_____ 1040-470-04-009 APPROVAL* NKIKARCH " " H. L. William // H. t. William* 11/3/69 ALB* H. E. Gibbi /*/ M. E. Gibb* 1/15/70 QUALITY CONTROL (Chtet ChemleO W. E. Ault. // W. 8-_Ai.lt.12/31/6?---------------- G. W. Miller // G. W. Miller 10/30/69 HPTlON C MIMIC AL FORMULA MIXTURE WOW T>_______________________________ ___________ 3/13/66______________ lx 16 ox. Can or W.M. Bottle G. W. Miller CHAM ACT CPU TIC LIMIT* UNRESTRICTED INFORMATION (R) Appaaraneo and Color (R) Color, NPA, Moltan (R) Softoning Point, "C Acid No., mg KOH/g Claar, yellow aticky reain 2 Max. 46-52 0.05 Max. MBT MOO G-l G-4 115 116 MONS 049745 (R) Routine Anolyaia, All others Anotysed by request Only Monsanto OftOANIC CHCMICALl OIVIIION PRODUCT AKOCLOPRRO5O0VC6T0 COOK J0PT. 1 826.17 . FINISHED PRODUCT I_A_C__18I42666.120 ____ Salai_____________ SPECIFICATION 10/21/69 1040-450-04-009 PRODUCTION APPROVAL! hftiMAAcH 1 .. H. L. Will Urns // H. L. William* 11/3/69 iZUTi--------------------------------------- M. E. Glbba /a/ M. E. Clbba 1/15/70 OuAUTv CONTROL (ChM Chemist) W. E. Ault /a/ w. E. Ault 12/31/69 G. W. Miller /a/ G. W. Miller 10/30/69 9SNCRAL OCaCRlRTION CHCMICAL FORMULA MOW RT. MIXTURE 3/11/66 1 x 16 oz. Can or W.M. Bottle G. W. Miller UNRESTRICTED INFORMATION (R) Appearance and Color (R) Softening Point, C (R) Acid No. mg KOH/g Black, brittle resin 105-115 0.5 Max. G-l 115 116 MONS 049746 WINCIM (R) Routine Analysis, All others Analysed by reguest Only Monsanto OXOANIC CMCMlCAlft MVtfttOM FINISHED PRODUCT SPECIFICATION production H. 1. William. 5/20/69 will 1M" W. I. Ault 6/10/69 llPTlOM PRODUCT AR0CL0E 5460 (HIGH SOLUBLE GRADE) PH660CT COftl 1j0CT. BIB.17 Annlaton ____ 626.22________ SiIf _ ___ 5-20-69 1040-460-04-009______ ;__________________ rIiIAAch--------------------- :---------------------- ------------------------------- -- -- ' M. E. Gibb* 6/13/69 QUALITY CONTROL (CMml Cftemlet) 0. W. Miller 5/20/69___________________________ CMKSMQAL FORMULA MIXTURE MOL Wt. ' Iupcricbci tote*. ot> 3*11*66 6 HAM ACT COIITIC LM*LI rM ANALYlll iiiawco v 1 x 16 oi. Can or W. M. Bottlk LIMtTl c- W- Millar MCTHOO UMREBTRICTED INFORMATION (R) Appearance and Color (1) Color, HPA, Molten (R) Softening Point, *C (R) Solubility (25g in 25g Acetone 9 25*C) Aold Mo., mg KOH/g Chlorine, X RESTRICTED INFORMATION Hydrolyaia Stability, ppm Cl Clear, yellow to amber brittle realn or fleker 2 Max. 98 - 105.5 3 hour, Min. 0.05 Max. 58.5 - 60.6 300 Max. 0-1 G-4 115 117 116 093 092 (R) Routine Analysis, AH others Analysed by request Only HONS 049747 Monsanto BABUDaifl nrtKiNCt TO P. D. Fowlkes - Research Center July 15, 1970 AROCLOR 5432 SPECIFICATIONS : ----- =?G. L. Arnett - ANNISTON cc W, R. Richard R# W. Weiss L. R* Stark J. R. Savage Q. E. Thompson H. L, Williams G. W, Miller J. T. Bell JSAVA ANNISTON ANNISTON ANNISTON This is to confirm our phone conversations regarding the following Aroclor 5432 tentative specifications. Specific gravity: 1.263 - 1.290 which corresponds to a chlorine level of 30.5% - 33.OX Color g 2 NPA These specs will be evaluated and possibly modified with the eventual goal of producing a material with just enough chlorine to prevent the formation of in solubles. A P. D. Fowlkes ms kons Monsanto OS0ANIC CHIMICALI DIVISION PRODUCT MONTAR 1 pwoouefcool------------ oil |WT- 246 He 1 826.47 Am. '' FINISHED PRODUCT SPECIFICATION PRODUCTION Annla ton APPROVALS AIsoaWm 82868-82683 Still_______________ 6405-001-04-03/09-02-01 1 ' --*--------- "" ' " 1 " H L. William. 8/12/69 J. W. Mollov 9/29/69 M. S. Gibb. 9/19/69 JlLtl WAUTY CONTROL tCHfl Chemist) W. B. Ault 9/17/63------------------------------------------------ R..JL- Blower. 9/30/69 0. W. HUl.r g//69 cncral dcscription chcmical formula MIXTURE MOL WT._________ 9/25/67 C NAR AC T CRIB TIC UNRESTRICTED INFORMATION 2 x 16 ox tf.M, Bottle* LIMITS G. W. Miller MOTMOO AnaUtat WCK (R) Appearance Black Vl.cout Liquid - -S.ml.ol id (R) Acidity, mg KCH/gm Basic Typical Phy.lc.l Prop.rtle. Chlorine Content, % 36-42 Calcium Oxide, X 5-15 Fla.h Point, `F COC 500-620 G-l 11321 050 10087 093 ... 114 10123 MONS 049749 IN-tM (R) Routine Analysis, All others Analysed by request Only MONSANTO CHEMICAL COMPANY. ORGANIC CNKMCALS fHVISION Krummrlch and Anniston FINISHED PRODUCT SPECIFICATION PRQQUCT CODS 82868 US ALU COOC See PAOOUCT (TMMt *) Montars 1 and 2 PRODUCT rOkMlMl Polychlorinated Polyohenyls CMRMCAL FORMULA jOtPT. OR JOG IWOK 246 Ann. Sales Below TTPR TYPR 2' Issued JIJU51964 W. QvKrunmriah Jlinl By Mixture ML WT. 6-15-61 AMPLI FOR ANALVMS 2 x 16 QZ. W. M. Bottles___ UNRESTRICTED INFORMATION Routine Tests Speclfloatlon Appearance General Information Black Solid Physical Properties (Typical values) Montar 1 ftenlng Point (ASTM E-28-51T) Aoldlty 54-l60*C Slightly Basic Chlorine Content 36-42* CaO Fe Bensene Insoluble 5-15* 0.5-1.0* -- Flash Point RESTRICTED INFORMATION 500-620*F Anniston WOK Method woT~~ 14-17-52 11J21 Montar 2 70-170*C Slightly Baal 44-48* ' 5-15* 0.5-1.0* 12.5* ---- Montars 1 and 2 are the still residues from distillation of Aroclors 1242 and 1248 respectively. Composition of these Montars is not controlled, being entirely dependent on conditions required to make acceptable distilled produot. Sales Code Nos. Montar 1 6405 - 001 - 04 - 03/09 Montar 2 6405 - 002 - 04 - 03/09 MOWS 049750 MONSANTO CHEMICAL COMPANY ORGANIC CHIMCAU DIVISION Krummrloh and Anniston FINISHED PRODUCT JUL 1 5 1964PRODUCT COO* 82868 Ut* Sales DIPT* OR JOO WOK 246 Ann.27 Issued We <ie Jiruniu'ion By Fianc lALtt COO* 1 SPECIFICATION *See Below PRODUCT (Ttarfe Hum*) TYP* Montaro 3 and 4 product Polychlorinated Polyphenylo typ* MOL VY. OPVPBRtCOCI IPRCC 6-15-61 Mixture AMPLR TOR ANALVMB 2 x 16 oz. VI . M. Bottles UNRESTRICTED INFORMATION Routine Tests Specification Anniston WflE Method No." Appearance Black Solid 14-17-52 113 General Information Physloal Properties (Typical Values) ( jftenlng Point (Method ASTM E28-51T) Acidity Chlorine Content Montar j3 86-168`C Slightly Basic 50-52* Montar 4 92-206*0 Slightly BBS 54-56* ' CaO 5-10* 5-10* Fe. 0.3-0.6* 0.5-1.0* RESTRICTED INFORMATION Montars 3 and 4 are the atlll residues from distillation of Aroclors 1254 and 1260 respectively. Composition of these Montars Is not controlled, being entirely dependent on conditions required to make acceptable dis tilled produot. *Sales Code Nos. Montar 3 6405 - 003 - 04 - 03/09 Montar 4 6405 - 004 - 04 - 03/09 HONS OA9751 t Monsanto PINISHKD PRODUCT SPECIFICATION production R. G. Moodv /s/ R. G. Moody 4/6/67 mu........... W. E. Ault /a/ W. E. Ault 6/30/67 MOOUCT Monear 5 Anniston raasuif ttu 828.68 mi Salae |OI*T. 1 26 1 ................ . 7-5-67 6405-005-04-009 1'ii'iine^ -- L. R. Stark /a/ L. R. Stark 7/5/67 QUACtTV CONTROL (ChM ChtmfcO G. W. Miller /a/ G. W. Miller 3/28/67 CMCMICAl formula Mixture e HAN AC TCRIIT1C rM amai.vaia l pint can______ 4auaa v "' John A, Diddle 3/22/67 UNRESTRICTED INFORMATION (R) Appearance Dark brown or black solid C-l (R) Softening Foint C 155 - 230 115 RESTRICTED INFORMATION Acid No. (mg KOR/g) Cl, X CeO, X Slightly basic 53 - 55 1-3 116 093 Fe, 7. 0.1 - 0.2 Flaeh Point "T Fire Point *F None None 114 114 Monter 5 Is the still residue from distillation of Aroclor 5460 HONS 049752 (R) ffeMtni Anolvai*. All oiHirt Anolvfd bv Only Monsanto OROANIC CMtMICAlt DIVItlON PRODUCT |oeT. 1 28 FINISHED PRODUCT SPECIFICATION Hoigi+iON R. C. Moodv /s/ R. G. Moodv 4/6/67 inn W. E. Ault // W. E. Ault 6/30/67 Anniston 826.68 JL-i-57____________ 6405-006-04-009 APPROVAL* Self___ __________ L. R. Stark /s/ L. R. Stark 7/5/67 1 QUALITY CONTROL (CMt ChamltO G. W. Miller // G. H. Millar 3/28/67 Mixture ml wt. lUMMIBII OR um____________________ CHAKACTimaTIC DMRESTRICTED INFORMATION MMA,| PM AMAWVAIA 1 pint can____________________ LIMIT* IMUBR O v ' John A. Llddlc 3/22/67 MaTnaa (R) Appearanc Dark brown or black liquid 0-1 (R) Softening Point *C RESTRICTED INFORMATION 135 - 190 115 Acid No. (mg KOH/g) Cl, X CaO, X Slightly baalc 59 - 61 2-5 116 093 Fa, X 0.2 - 0.4 Flaah Point *F None Flra Point *F Nona Montar 6 la the still raaldua for distillation of Aroclor 4465 114 114 (R) Routinm A nalv/i im . All MONS 049753 Omt< Monsanto OHOANIC CMCMICALS OIVIIION PINISHID PRODUCT SPBCIPICATION eeeoucTiON X. G. Moody // R. G. Moody 4/6/67 nen--------tt. E. Ault /a/ W. E. Ault 6/30/67 pnoowct (ocet. Annie ton 128.68 S1m 7-5-67 6405-008-04-009______________________ __ minweu R. St*rk /$/ L. R. SUtk 7/5/67 S. W. Milltr // G. W. Millor 3/28/67 I fixture * - * M0L WTi 1 Tontotlvo 5/5/61 I CHAR AC TCHIt TIC AMVI.C POR ANAAVKI i pint can LIMIT* BMRESTRICTED INFORMATION (R) Appoerance Black solid ; ^R) Softening Point *C ilSTRICTP IHFORMATIOM 200 Min. Montar 7 is Aroclor 1268 still residue >Hw4*v " 1 John A. Llddls 3/22/67 MtTMM 0-1 115 it { t\ <<3 "'1 t O' (A/ Routine Analysis. Alt others Analysed by reouett Only HONS 049754 '* Monsanto Chemical Company ONOANIC CHEMICALS DIVISION ANNISTON, ALABAMA J| PRODUCT COOI 823.68 MCTMOO IOCNTITV FINISHED PRODUCT SPECIFICATION proouct (Trad* namei SAL Cl COOS below MPNTAR 3, MONTAR 6. MONTAR 9 PROOUCT (Chemical namt) CHCMICAC FORMUL A Iaauad 5/5/61 By Anntaton Plant Standards Dapt. MIXTURES lUPlRSIDtl SPECS OF 7/29/55 *SCIM. m W3. | SAMFUI FOF ANALYSIS 1 Ft. Tinned Can UNCLASSIFIED SPECIFICATIONS Routine Taata Property Specification Appearance Dark brown ox black solid SENERAL INFORMATION Salat Typical Valuae Softening Point, *C (ASTM E28-51T) Acidity (mg KOH/g) Cl (7.) CaO (7.) Fe (7.) Plash Point (*F.) Firs Point (F.) Salts Codest Montar 5 Montar 6 Montar 9 lightly basic all / 1-3 6405-005-09-09 6405-006-04-09 6405-009-04-09 ly basic Montar 9 130-175 0.1 - 0.3 0.2 - 0.4 450-550 530-630 RESTRICTED INFORMATION Montar 5 is the still residue from distillation of Aroclor 5460 Montar 6 is the still residue from distillation of Aroclor 4465 Montar 9 is the still residue from distillation of Santbwax R. . Composition of these Montars is not controlled, being totally-dependent bn condi tions required to maka acceptable distilled produce. HONS 049755 Monsanto OAOAMIC CMCMlCAbl OIVIOION FINISHED PRODUCT SPECIFICATION fl VTIVB 5-7-68 aifbaocT !VII"""1 "" D,i~" 1 " 826.01 UlU 1888 Salaa 1313-000-03-09 PRgromSffH. L. Will Una /a/H. 1. Williams S/2/68 nun W. R. Ault /a/V. K. Ault 5/7/68 L. A. Stark /a/John P. Harbar OualiTv contnou (Cfiimt dhmtitd G. H. Millar /s/G. V. Millar 4/29/68 CMIMCM. rOMMVLA White, crystalline lolld MOW WT. -a-A-fti. AMAkK AM ANAlV.IA 1 x 16 e. cn (R) Appaaranea (R) Cryatalllalng Point, 'C (R) Color, Cardnar Whita to pala yallow oryatala 68.7 Min. 6 Max. Canaral Taata (determined only on request) Biphenyl, R Dlatlllatlon Range (Muat Include ltt Drop - Dry point, 2.S*C 255*C) C12H10 " lllul. , y J L, Brown___________ Typical mthmi 99 9 018 019 165 MONS 069756 (H) Routine Anolytit, Alt other* Anolytod by requett Only ** Monsanto Cmsmical UnImny OROANte CHEMICALS DIVISION FINISHED PRODUCT SPECIFICATION FwooucT (Trmit mmmi lphonyl mm)PRODUCT fUksstfeaf llphmyl CMSMICAL FORMULA PRODUCT CODI 816.01 MCTMOD IOOHT1TY f If SALKS COOK 115-000-03-08______________ ttpe toehnleal type Tschalcsl laanad S/5/61 Annliton Plant y W. H. Klwuaar lavload to add tyy valwaa 11-18-65 % ftuHRiibCISPBCSOP Ci,Hio jt| VSCHL NO. SAMP IE PON ANALT SIS MOL WT. 154.20 VIE Salos Charactorlatlca RcutlnatMta Anurnei Cryatallltln| Point, *C Color, Oardnar Ll.lta White to polo Follow orpotalo 68.7 Kin. 6 Has. CoBotol toot (dotonalnad onlr on roauaat) lphonyl, X NapthaIona, X 3 - Natbylblphanyl, X 4 - Mathylhlpbanyl, X Unknown, X Dlatlllatlon lanpa, *C lot drop - #ry Folne Muat Include 255*C Trolenl Valuaa White cryitol* 68.8 l.S 88.9 0.001 0.05 0.02 <0.03 / HONS 049757 This opacification for Internal uaa only Monsanto OftOAMIC CNIMICAI.I omilON FINISHED PRODUCT SPECIFICATION PRODUCT SANTOWAX C |mt 1 826.02 Annlaton 10/21/69 829.10 mu coos Internal 7795-050-11-009 PRODUCTION H. L. Will Itmi // H. L. Will Urnft 11/3/69 Mbit M. E. Glbba /a/ M. E. Glbba 1/8/70 QUALITY CONTROL fCMmt ChM'lmU W. E. Ault /a/ W. 8. Ault 12/31/69_________ G. W. Millar /a/ C. W. Millar 10/30/69 MOW WT. MIXTURE 3-9-66 eM&M *.CTtmTie RE8TRICTS0 INPOTMAHOH Appaaranca Bolling Point, *C Ortho Tarphanyl, l Mata Tarphanyl, X Para Tarphanyl, X Quatarphanyl, X Biphenyl, X Plaah Point, *C Chlorine, ppm Sulfur, ppm AMPCC IVON ANALVIII 2 - 1 pt. Cana G. U. Millftr Brown, waxy aolld 350 Min. **10 **50 **26 **14 **0.1 **375 2.0 (Typical) 2.0 (Typical) G-l 064 064 064 072 064 114 Distribution of isomare and quatarphanyls vary with operating condition. Only limited data la available; therefore, tha limit* given ara typical value* of thaaa charactarlatlca. Thla product la aialnly uaad a* a raw material for other flnlahad product* produced at Annla ton. Thla aptclflcatlon la for Internal ua* only. HONS 049758 (R) Routing Analytic, Alt ethart Analyted by request Only 1 waK'iM Monsanto OAOAftIC CHIMICAL* OimOM FINISHED PRODUCT SPECIFICATION PK90UCT 10/21 /M SANT0UAX M PNWUCT 1 826.04 . l_l_l_ll8(2H4JI3________ ___Salta______________ ____7795-200-11-009______________________ W!SFuTTio5------------------------------ ' Utnt*"" /,/ H~ L~ Vllllm 11/3/69 B. E. Ault /./ W. E, Auli-12731/49_- nurtifH-------------------------------------------------------,iU B. ffW // M. E. <?W 1/9/70_____ 0UAL1T Y CONTROL fCMW Ch--tllO C. W. Miller // C. W. Millar 10/30/69 MOL XT. TERPHENYL MIXTURE 3-4-66 CHAMACTIHIETIC UMRESTRICTED THFOUMATIOH (R) Color, Gardner (R) lat Cry*tala, *C (R) Hold Point, *C RE8TRICTED IMFORMRTIOM M-Terphenyl, X 2 - 1 pt. Cana UWTI 6.0 Max. 93 Max. 80 Min. G. U. Mllltr MITMM 035 032 119 95 (Typical Valua) 044 WN'IM (R) Routint Analytis, All oihtrt Analyttd by request Only HONS 049759 Monsanto OftOANlC CMgMICALl OMMSiON PKOOUCT PLANT SANTOWAX 0 PMODOCT COOS lofPT, l lB I 926.02 FINISHED PRODUCT SPECIFICATION PRODUCTION Annlaton 10/21/69 *PPRO*U RKSEAACM 826.06 SALKS CODE 7795-300-11-009 Sale. T " H. L. Will tamo // H. L. WlllUmt 11/3/69 M. E. Glbba /a/ M. E. Gibb. 1/6/70 nun--------------------------- ----------------------------------------- QUALITY CONTROL (Chief ChemleO W. E. Ault // W. E. Ault 12/31/69 G. W. Millar /a/ G. W. Millar 10/30/69 7 ItPTION C Ml MIC *L POAMUL. TERPHENYL MIXTURE MOt, AT. SUPERSEDES SPEC*. OP 3-2-66 CHARACTERISTIC AMPLE FOR ANALYSIS 2 - 1 pt. Cans LIMITS UNRESTRICTED INFORMATION (R) Color, Gardner 5.0 Max. (R) Hold Point, 'C 49.0 - 54.5 (R) Dlatlllatlon Range, *C lit Drop 333 Min. 96% by wt. 350 Max. G. W. Millar MOTMOO 035 119 130 RESTRICTED INFORMATION O-Terphenyl, % 95 (Typical Value) 072 HONS 049760 MK>lN (R) Routine Analysis, All others Analysed by request Only Monsanto OSOANIC CHtMlCALl DIVISION proouct SAMTOWAX P PNODOCt e66K jo*pr. 1 E2&.0A FINISHED PRODUCT SPECIFICATION pwoowetioN Anniton ____ a26_,Q7_________ lAkll COOK --10/21/02________ APPROVAL* HOTIarch 7795-100-11-009 1 H. L. Williams // H. L. Williams 11/3/69 ticut M. E. Gibbs // M. E. Gibbs 1/8/70 QUALITY CONTROL (Chft ChmmUl) W. E. Ault /s/ W. E. Ault 12/31/69 ttNCMM. OCtCRIRTION _G^_W. Miller /s/ G. W. Mlllsr 10/30/69 CMIUICtL POHUULA TERPHENYL MIXTURE MOW WT. lUMRHBII IRCCI. OP 6-9-66 Char act critic AMP LC POR ANALVAII 2-16 oz. W.M. Dottles LIMIT* G. W. Miller MCTWOB UNRESTRICTED INFORMATION (R) Color, Csrdnsr CR) 1st Crystals, `C 4 Max. 207 Min. 033 032 RESTRICTED INFORMATION P-Terphenyl, X 98 - 99,5 064 MQNS 049761 WOK* Ml (R) Rautint AnatysU, All othtr* Analyttd by request Only Monsanto OftOANIC C Ml MIC A u# OMflSION PAOOuCT PClN-f **4duct cSSt ull------- 826.02 FINISHED PRODUCT SPECIFICATION PAOOUCTION 10/21/69 A^PHOY At.* fttatAftiH nnr Sl .7795-m-llrm. -- , H. L. William* // H. L. William* 11/3/69 *UJi M. E. Gtbba /a/ H. E. Gibb* 1/8/70 QUALITY CONTROL (CM*/ CAom/aO W. E. Ault // W. E. Ault 12/31/69 G. W. Miller // G. W. Miller 10/30/69 HFTtON CHKMICAU FOMMULA a MIXED TERPKENYLS MOL WT. uMAacBa* *c. or 3-2-66 UM8LI *96 AnALVIII 2 x 1 pt. Cana G. W. Millar UMEMTRICTED INFORMATION (R) Appaaranee (R) Color (liquid), NPA (R) Upper Hold Point, C (R) Lower Hold, *C Yellow whit* noncryatalllne flaked aolld 4.0 Max. 136 - 145 48 - 63 G-l 128 129 129 RE8TRICTED INFORMATION Dlatlllatlon Range, *C, 80% (Uncorrected) Ortho tarphanyl, % Mata tarphanyl, % Para tarphanyl, % Quatarphanyl*, % 350 - 400 10.0 - Typical Valu* 54.0 - Typical Valu* 27.0 - Typical Valu* 9.0 - Typical Value WON* AM (R) Routine Analysis, All others Analysed by request Only HONS 049762 Monsanto OPOANIC CMtMtCALS OIVIIIOM PRODUCT ,. , SANTOWAX 01 J9CPT, 7*1 126. FINISHED PRODUCT SPECIFICATION Anniston ____ W21/69.. 629.52 ___Sftllfl_______________ 7795-500-11-009______________________ PRODUCTION H. L. William. // H. L. William. 11/3/69 Hull W. E. Ault fa/ W. E. Ault 12/31/69 leniPTiOM RCIIANCH M. E. Gibb* // M. E. Gibb. 1/8/70 QUALITY CONTROL (Chft CflMtltO G. W. Miller /$/ G. W. Miller 10/30/69 chmic a*. roRHUb* MIXED TERPHENYLS mow wr. UPSMCOM PCCS. OP 3-2-66 eNANACTlRlITIC IAMPLC PON ANALYtt* 5 x 16 oz. Hide Mouth Bottle LIMITS G. W. Miller MSTM99 UNRESTRICTED INFORMATION (R) Ortho/Met. Ratio (A) Solution Point, *C (R) P-Terphenyl, Z (R) Biphenyl, Z Hl-Bollr (Quaterphenyle), Z (R) Ath, ppm (R) Molitur., ppm (R) Elemental Impurltlaa, ppm Boron Cobalt Iron Magna.lum Chlorlna Sulfur Sodium Pho.phoru. .Aluminum Mangana.e .Copper .Barium .Calcium .Lead Molybdenum 1.5/1 to 3.0/1 85 Max. 5 Max. 3 Max. 1 Max. 5 Max. 200 Max. 0.5 0.1 2.0 0.1 2.0 10.0 0.2 8.0 064 096 064 064 072 065 034 Determined by Re.eareh by Euleelon Speetro- copy II *t 093 127 070 088 Determined by Re.eareh by Emla.lon Spectro- .copy It II II II I II II II .Report the value obtained. MOMS 049763 (R) Rtutina Antlyais, All alhers Analyzed by request Only Monsanto OMOANIC CHEMICAL* OlVItlON PRODUCT .,, SANTOHAX 01tt (Reector Gtad) PRODUCT dol 1 826.35 FINISHED PRODUCT Anniton AAfl IWffiTIVI _______ 826.32____________ Selee_________________________ SPECIFICATION ___ 10/21/69 APPROVAL* ________ 7795-8QQ-U-0Q?_________________________________ PRODUCTION MUkRt H ' " -- 11 H. L. Will lira. // H. L. Wllllimi 11/3/69 M. E. Gibbs // M. E. Gibbs 1/8/70 ITCTI------------------------------------------------------------------ OUAUITV CONTROL (CMt CltamlaO W. E. Ault // W. E. Ault 12/31/69 G. W. Nlllir // G. W. Miller 10/30/69 INERAL OMCRIPTION CHEMICAL FORMULA TERPHENYL MIXTURE 3-A-66_________________ 3 x 16 oe. Wide Mouth Bottle G. W. Miller characteristic LIMIT* METHOD UNRMTRICIED 1MFORMAXION (R) Appeerence Light yellow to yellow wexy eolld G-l *(R) Terphenyl, X (R) Biphenyl, X 96% 1.0 Hex. -036 (R) High Boiler, X 1.0 Mex. 033 (R) Solution Point, *C 137 Mex. 032 (R) let Cryetele, *C 156 Mex. 032 (R) Weter, ppm 500 Mex. 034 (R) Chlorine, ppm 2 Mex. 093 (R) Treee element!, ppm Al B Co Mn Cu As Be Ce Cr Fe Pb Mg Mo Ni Si Ag 8n T1 1.0 0.5 0.1 0.1 2.0 0.5 2.0 10.0 1.0 10.0 4.0 1.0 1.0 3.0 3.0 0.1 1.0 5.0 Detsminsd by Rssssreh emieelon epectroeeopy MONS 049764 WE Me IM (R) Raittlma Analyaia, Alt othata Analyaad ky rfw< Only SANTOWAX OMP (Reaccor Grade) (R) Tract tltmtnta (continued Zn Zr Se Hg 8 P Na 1.0 1.0 0.5 0.1 60.0 8.0 0.2 Page 2 Determined by Research by emission spectroscopy 127 088 070 RESTRICTED INFORMATION Color, Gardner Ttrphtnyl, X Ortho Meta Para Quatarphanyl 11 11.8 (Typical Value) 55.0 " " 31.2 " It 2.0 035 064 064 Determined by difference: 100X - (S Biphenyl + % High Boiler) - % Terphenyl MQNS 049 765 Monsanto FINISHED PRODUCT SPECIFICATION PRODUCT Santmax 1 Anniston 3-2-46 IOPT PRODUCT COOK 132 ul--------- " ____________ Jllll_________________ ms.-m-11-w_________________________________________ PRODUCTION H L. R. Stark // 2-3-66 - M QUALITY CONTROL (CHM Ch--tfrt) W. Ault /./ 2-22-66________________________ 0. E. Dolln /./ 1-23-66 iiption emmeL Kelvin // 2-22-66 Mixed Terphenyle WOL NT. IU#IM(BII CPCCC. OP~~ 2-12-62 CMAnACTKNJBTIC UNRESTRICTED INFORMATION (R) Appearance (R) Color (liquid), NPA (R) Uppar Hold Point, *C (R) Lower Hold, *C RESTRICTED INFORMATION Dlatlllatlon Rang*, *C, SOX (Uncorractad) Ortho tarphenyl, X Mata tarphenyl, X Para tarphenyl, X Quatarphanyla, X VauPLC POR A*4Alv5> l_ I x 1 pint cans MMIT _ IlllUID IV ~ ' "" J. A. Llddla 1-11-66 MIT HOB Tallow white noncryatalllna flaked aolld 4.0 Mas. 136 - 145 48 - 63 O-l 128 129 129 350 - 400 10.0 - Typical Value 54.0 - ' " 27.0 - " " 9.0 - " " MON$ 049766 WON* IM (Rl ftoultat AnalytU, All olAtrs 4noJyicd by r*fue*t Only Monsanto MATERIAL COOK MATCRIAL 826.38_________ A*. ANT CHLORINE GAS RAW MATERIAL SPECIFICATION PRODUCTION Annlaton 826.08 and 826.17 ORPMtR 12/17/69 ---- Diamond gh.-rock Com._______________ APPROVALS AltlAEtN E. L. William* /*/ H. I*. WUlUm* 12/17/69 M. E. Glbba // K. A. Taraatra 12/22/69 OUAUTV CONTROL (Chl*4 Chmtitf) BxJi. Fhlllls* // H. L. PhlUlo. 12/18/69 G. W. Miller // G. W. Miller 12/17/69 HRTION chsmol pqrmwua CRES118B YELLOW GAS IU8IRIIOII PICI OP AMPLE TOR AMALYaia isoule sr ' 1" kCTSRIVTie LIMIT* MKTHOO (*) Aaaay, (Vol. X) (1) Raaldual Gaaaa (Vol. X) (R) Molatura, ppm (R) Hon-volatllo Hatear. ppm 99.6 Min. 0.3 Max. 40 Max. 40 Max. 113 113 (SI RMln* Analfmlh All MPf* hr rfu* Mlr> HONS 049767 Monsanto MATKHIAL coot . 17860 PLANT MATERIAL PA1MN niOXIDE RAW MATERIAL SPECIFICATION OPUeriOH itt&lttOB DATS rrSCTtVB 12/18/69 APPROVALS HIran & BLohonvl Pura Carbonic B. L. Hll liana /a/ H. L. Will Una 12/19/69 M, 8. Gibb* // M. I. Glbba 1/5/70 CVALITV CONTROL (CAM CAiIgU B. L. Phlllloa /a/ R. L. Phlllloa 12/19/69 G._W. Millar /a/ C. W. Millar 12/1B/69 IKAIPTIOH OHWtAI. FORMULA COLORLESS, ODORLESS GAS OR COLORLESS LIQUID CO* Mol. We. 44.01 "4vMr4o pc 10/21/69 laiiitl m mwUm tsttii iWUibaV---------8. h. mui owbhtmctbp imtobmaticm Carbon Dloxlda, l Hltrogaa, % Oxygon, t Molatura, X Total Sulfur, ppn 99.87 Min. 0.05 Max. 0.01 Max. 0.07 Max. 1.0 Max. Tbata (pacification* ar* thoaa aat by th* auppllar for flniahad good*. <IU RMIw AMlftlt, Alt (than AaatyHd by nyuast ntj* MQNS 099768 Monsanto RAW MATERIAL SPECIFICATION 38(00 Anniston 0ATK BPFBCTIVC 6-22-70 APPROVALS MATCNIAL LIME HYDRATE (VERTICAL HYDRATE ONLY) lHN OBPT1. ' _" Aroclor -- 826.08 A 826.17 Alabnatsr Lima Co. H. L. Will lama /./ 8. L. William. AR0CURKMINT B. L. Phillip. // H. L. Phil1lot timiiti. oi.cw.tiox 6/24/70----- W. R. Richard/./ W. B. aich.rd 7/4/79 OUALIT V COMTMOV fCMW CAmiIaU m 6/23/70----- I, Bll /a/ J I. Ball 6/22/70 w >. WHITE FINE PCMDER USN*OM Of* iempli ren anewyiii Typical Analytic C(0H)j Mol. vt. - 74.10 m, i,. am mtamiw iwmxm CaO, l NgO, X sio2, X AljOj, X Fa20j, X Ignition Loan, X Ca(0H>2> X (Calculated) 73.00 1.20 0.36 0.60 0.30 24.04 97.501 3cran AnilYX<if Through 200 math, I Through 32) math, X 99.8 94.) 120 Batli of Spaclflcattona: Suppllara typical analyalc of product (5/23/64) 1Ca(0H>2 * - loot - ^MgO (t) + SlOj (t) + AljOj (t) + F.jOj (t).7 MONS 049769 (Hi jimiHa* WK'I4 An thf An/r*4 r < m( Monsanto 48289 LANT REGULAR POROCEL RAW MATERIAL SPECIFICATION Annloton 826.08 OATS PFKCTtvK uppLiAp p0roc*l Corp. (A Sub*Id. ot _____12/18/69____ Mloorol 4 Chanlcala Phllllo Coro.l APPROVAL* AtllARCH , L WtlllAM 1,1 M. L. William* 12/19/69 PHOCUIIIMCMT a. L. Phllllpt hi H. L. Phillip* 12/19/69 M. R. Gibb. /*/ M. t Clbb* l/S/70 OUALIT V CONTAOL fCMW CJtMftO fl. M, Killor // C. W. Millar 12/18/69 ' ItCAIPTION CMIfC AL POAHVLA ACTIVATED BAUXITE inciV iaiiwu reft analysis iMun v 1 LIMITS MCTMOD (A) Appooranc* (R) Math Taat: Lata than 60 Maht 20 to 60 moth lncluoivo: Ortatar than 20 math: (R) Watar Volattla Mattar (at 1000*C to eonotant wol(ht) Frto from lumps and fortlfA motorto1 31, Max. 67%, Min. 30%, Max. 1%, Max. 2%, Max. fJU RmIM* 4iMfr>l*i 411 flftm 4nafrMtf ky W*K*M Aff> MONS 049770 "ruv i ' '' Jvrwt-H y*i v" . Monsanto MANIC eNBMCtkl DIVISION MATMlAb COM 19400 PLANT ' Utiialni Barth - **M Srado UOINO DIRTS. RAW MATERIAL 27-L SPECIFICATION MMUCTION 7-20-66 APPROVALS ______ RJM 00l0______________ . 0. Mood* //*. G. Mood* 6/9/66 AROCURCMINT R. r. Moollor /s/R. F. Muollor 7/13/66 QUALITY CONTROL fCMW Cftfif> L. Phillis* //. L. Fhlllloi 6/10/66------- 0. 1. Dolln //0. B. Dollo 6/8/66 l*CWIPTIOH >QHm I^uri Hydrous MagMslim Alwlavi Sllleat* lift i Xi 1M7 CMARACTIRISTIQ AMRLC TOR AMALTDID l.Ahi.aa,... LIMITI ummuictid IBTOBHATIOH Scrasa Analysis Through 200 Mash (X) 95 Min. Loss on Ignition (X 0 950*C) 15 Mas. Tyylcal Analysis from Supyllsr (May 23, 1966) 10j (X) AljOj (X) 67.5 12.8 FSjOj (X) 4.5 HgO (X) CaO (X) 1^0 (X) 11.1 1.6 0.8 RajO (X) 0.1 TIOj CX) Othar (X) . 0.6 1.0 IHUID IV ll. A. Llddla - 5/23/6* MCTHQD MONS 049771 (W ***** iliwti'rtA All xOfR Atf*nrf or wmii (a MMM Monsanto RAW MATERIAL SPECIFICATION try. ~nrk. AT0K1ZSD Aluminum Povdtr 6 MAI TIC CA**c MATCMIAt. COOS 11731 At ANT Alualnua Fowler HD-101 AnnItton 12/28/70 826.17 UAALIBM Alcan Matal Powder* APPROVALS I8CSIAACH w. R. Rlchard/S/W. R. Richard 2/71 AUA1.IT 4fcu*f _. _J<uSJT _ _ _ _ _ _ _ _ _ J. T. tell6 MimiMCTP IHFOHtMlOH Apparent Dtntlty (g/cc) 1.1 Fra* Metallic A1 (X) 99.3 Average Fardel* Sit* (Kleron*) 16 lev* Aoalytle (X) + 100 Trac* + 200 10 + 325 10 - 325 80 That# (pacification* ar* tho** *t by th* auppllar for flnlahad good*. (JU JImmHm AnWfalg, All AnifM ky nhoi onir. MONS 049772 Yol. S CHLOKOCARBONS AND CHLOROHYDROCARBON8 289 24. W. J. Davey, / In>`- Prirol.11, 73-88 (1948). 28. F. M. Rows, ad., Cdmtrlndtz (Cl), lit ad., Soaiaty af Dyera and Colourist*, Bradford, York shire, 1924; Supplement, 1928. 28. Brit. Pat. 310,910 (Juno 28, 1929). N. Bannatt and W. C. Sprant (to Imperial Chamioal Indua- triia Lid.). 27. U.S. Pat. 1,887,183 (Oat. 13, 1928), A. Oooria (to Mathlaaon Alkali Worka). 28. U.8. Pat. 1,091,648 (July 8, 1920), F. E. Stookalbaak (to Mathieaon Alkali Worka). 20. Oar. Pat. 234,200 (1000) (to Badiaaka Amlin- und Soda-Fabrlk AO). H. Sipi Heyden Newport Chemical Corporation CHLORINATED BIPHENYL AND RELATED COMPOUNDS Biphenyl (diphenyl), terphenyls, higher polyphenyls, or mixtures of these com pounds can be chlorinated to give products which have outstanding chemical and thermal stabilities. Individual isomers, which range from liquids to high-melting erystalline solids, are of little commercial importance whereas the mixed chlorinated components have considerable commercial significance. Registered trademarks for some commercial brands of chlorinated biphenyls in the United States are the following; Aroclor (Monsanto Company), Chlorextol (Allis-Chalmers Manufacturing Company), Dykanol (Cornell-Dubilier Division, Federal Pacific Electric Company), Inerteen (Westinghouse Electric Corporation), Noflamol (Wagner Electric Corporation), Pyranol (General Electrio Company), and Therminol. (Monsanto Company). Some other registered trademarks or trade names for commercial chlorinated biphenyls found throughout the world are the following; Clophen (I. G. Farbenindustrie A.G., Germany), Fenclor (CafTaro, Italy), Kannechlor (Kanegafuchi Chemical Co., Japan), Pyralene (Prodelee, France), and Sovol (Russia). Commercial manufacture of the Aroclor brand of chlorinated biphenyls was started in 1920. These products vary from mobile oily liquids to white crystalline solids and hard noncrystalline resins. Because of the many forms and properties, they have found applications in many diverse fields--in eleotrical insulation, fireresistant heat-transfer and hydraulio fluids, lubricants for use at high temperatures and pressures, sealant and expansion media, and as constituents in elastomers, ad hesives, paints, lacquers, varnishes, pigments, and waxes. Physical and Chemical Properties The physical properties of individual chlorobiphenyl iBomers vary widely as may be seen in Table 1. Mixed isomers as produced in a commercial product have physical properties which are quite different from those of the individual isomers. This is piutloularly true for the solidification point. Chlorinated biphenyls, in general, are considered to be inert materials. How ever, they will react with certain reagents when treated under rather rigorous condi tions. FV>r example, chlorobiphenyls will react with sodium hydroxide at elevated temperatures to yield phenolio materials (28). Mixtures of chlorinated biphenyls, such as those found in commercial products, will not react with acids, alkalies, or water under normal to moderately rigorous conditions (29). They are insoluble in water, glycerol, and the glycols. The oils and 049871 290 CHLOROCARBONS AND CHLOROHYDROCARBONS rosins are readily soluble in most of the common organic solvents, but most of the hard crystalline members are less soluble than the liquids or softer resins. The ohiorinated biphenyl mixtures are nondrying even when exposed to air in thin films. They are permanently thermoplastic and except for the lower chlorinated members are nonflammable. The resins will adhere strongly to smooth surfaces such as glass, metal, varnished or lacquered surfaces. Most of the common metals and alloys Table t. Phyaiosl Properties of Chlorobiphenyls Compound 2-chlorobiphenyl 3-chlorobiphenyl 4-ohloroblphsnyi 2,2'-dicUloroblphenyl 3,3'-dichloroblphenyI 4,4 'iliclilurobiphenyl 3,6-dichlorobiphenyl 2,0-dlchiorobiphenyl 3,4-dichlorobiphenyl 2,3-dichlorobiphenyl 2,4'-diohlorobiphenyl 2,4,6>trichlorobiphenyl 2,3,5-lrichlorobiphenyl 2,4>4'>Lrichlorobiphenyl 2,6,4'-trichlorobiphenyl 3,C,4'-trichlorobiphenyl 3,4,2'-trichlorobiphwiyl 3,0,2'4rfchlorobiphenyl 3,4,3',4'-ttrachlorobiphnyl 3,4,2',5'*tetrachlorobiphenyl 2,6,2',9'ttraohlorobiphwiyi 2,5,3',5'-tetrachloroblphenyl 2,4,2',4'-ttmhlorobiphmyl 2,5,2',5 tetraohlorobiphsnyl 2,4,5,3',4'-pentahlorobiphenyl 3,4,6,3',4',6'*hexaohlorobiphenyl 2,4,6,2',4 ',6'hexachlorobiphenyl 2l3,4,5,2',4',6'-hopt*ch)orobiphenyi yl Melting point, *C 34 80 75.5;76;74 69; 61-62 23; 29 148 . 30 46;40-60 44 78-79 41 56-56 67 88 65-66 58 172 103 198 162 83 84-85 179 198 111.5-112 101 310 Boiling point, *C (mm Hg) 267-268; 164 (12) 284-285 125(14) 322-324; 320-326 315-319 166(10) 171 (15); 182(30) 198-200(16) 172 (30) 230 ( 50) 195-220(10) 240-280 (20) Hi (1-3) (4,5) (2,6,7) (8,9) (0-12) (2.9,12) 03.14) 04,15) d#,17) 05) 05,18) 09) 03) (9,20) (21) 03) (22) 03) (11,23) (21) (23) (23) 02,24) (23) 09,26) (23) 02,27) (19) (23) (23) have excellent resistance to the chlorinated biphenyls even at elevated temperatures. However, copper and some copper alloys are affected to a limited extent and show pene tration rates between 0.0014 and 0.014 in./yr. Many plastic materials of construction are attacked by chlorinated biphenyls. In addition to high resistance to thermal degradation, they also have many interesting electrical properties. The general properties of the more important members of the Aroclor brand of chlorinated biphenyl products are shown in Table 2 and the electrical properties are shown in Table 3. HONS 049*72 Vol. 5 CHLOBOCARBONS AND CHLOROHYDROCARBONS TaUe 1 Gcooal Properties of Sone Arodots Material Form and color Specific DMDatioD range,* *C (oorr) Flaab point,* c Fire point,* *C Pour point,4 *C Softening point,' *C * 37.8*C 98.9*C Aroelor 1221' Arodor 1232 Arodor1242 Arodor 1248 Arodor 1254 Arodor 1260 Arodor 1262 Arodor 1268 Arodor 1270 Arodor 4465 Arodor 5442 Arodor 5460 Arodor 2565 colorlem, mobile oil 1.182-1.192 (25/15.5*0 almost colorless. 1.270-1.280 nobis oil (25/15.5*0 almost polarises, 1.381-1.392 mobile oil (25A5.5*C) yellow green tinted. 1.405-1.415 mobile ofl (65AS-5*0 light yellow, viscous 1.495-1.505 <d (65/15.5*0 light yellow, soft, 1.555-1.566 sticky, resin (90/15.5*0 light yellow, sticky. 1.572-1.583 dear rerin (90/18.5*0 white to off-white 1.804-1.811 powder (25/25*C) whits crystalline 1.944-1.960 powder (25/25*C) transparent, yellow, 1.670 brittle resin (25/25*0 yellow, transparent, 1.470 sticky resin (25/25*0 dear, jeUow-to-nm- 1.670 her, brittle resin (25/2S*C) black, opaque. 1.734 brittle resin (25/25*0 275-320 141-150 290-325 152-154 325-366 176-180 340-375 193-196 365-390 none 385-420 aone 395-425 acne 435-450 one 450-460 none 230-320 (4 mm Hg) 215-300 (4 mm Hg) 280-335 (SmmHg) none 247 none none 176 crystals at 1*C 238 -35.5 1617-1618 1.620-1.622 38-41 44-51 30-31 31-32 none -19 1.627-1.629 82-92 34-35 none none -7 10 1.630-1.631 183-240 1.639-1.641 1800-2500 36-37 44-48 none 31 1.647-1.649 72-78 none 35-38 1.6501-1.6517 86-100 none 130-170* none 249-300* none >350 60-66 1.664-1.667 46 43-52 90-150 (130*C) 300-400 none 98-105.5 1.660-1.665 none 66-72 * ASTM D-20 (modified). * Cleveland open cup. * Cleveland open cup; none indicates no fire pout up to boiling temperature. 4 ASTM D-97. * ASTM E-28. 1 Saybolt Universal, ASTM D-88. * Last two digits indicate approximate chlorine content, ie, Axoclor 1221 contains about 21% chlorine. * Hold point on solidification. HONS 049873 292 CHLOROCARBON8 AND CHLOROHYDROCARBONS Table 8. Electrical Properties of Borne Aroclnn Dielectrio constant at 1000 ojrelee* Aroclor 26'C I0Q*C im 1242 1248 1264 1200 1208 6442 6464 6400 4466 6.7 4.0 6.8 4.0 6.0 4.6 5.0 4.3 4.3 3.7 2.6 3.0 4.0 2.7 4.2 2.5 3.7 2.7 3.3 A8TMD-160-47T. ASTM D-267-40. ASTM D-141M4. Volume resistivity,1 u-cm at 100'C, 600 V, do above 600 X 10* above 600 X 10* bov. 800 X 10* above 600 X 10* above 600 X 10* Dielectrio strength,* kV >36 >35 >36 >35 Power (actor,* I00*C, 1000 cycles, % <0.1 <0.1 <0.1 <0.1 Manufacture A numlK'r of the pure compounds formed by the chlorination of biphenyl, tcrphonyl, or more complex polyphenyls are crystalline solids, some of which have very high melting points (30). However, mixtures containing a number of such compounds may be cither liquids or noncrystalline resins. Chlorination of aromatic hydro* carbons to various levels not only gives several isomers of the same chlorine content but also gives appreciable portions of the isomers of compounds of higher and lower chlorino contents (31,32). At any level of chlorine content, batch chlorination gives tho highest proportion of compounds corresponding in composition to the average chlorine content, whereas single-stage continuous chlorination gives the lowest pro portion of such compounds. As the number of stages is increased, multistage con tinuous chlorination gives compositions approaching those obtained by batch chlo rination. The proportion of the various Isomers and of compounds of higher and lower chlorine contents than the average is also influenced by factors such as temperature, quantity and kind of catalyst employed, degree and type of agitation, and rate of admission of tho chlorine. A procedure for carrying out a angle-stage fluid-bed chlorination is described in tho patent literature for polychlorination of biphenyl (33). Continuous liquid chlo rination in a multiple-stage unit can also be used. Batch chlorination has been found to be particularly well suited for the manufacture of the various products (32,34). The chlorinators may be cylindrical steel towers, 3 ft in diameter and 18 ft high, which are equipped with chlorine distributors at the bottom and with coils for heating and oooling the material undergoing reaetion. Pumps provide agitation by circulating the liquid charge. The lower half of the chlorinators is filled with iron turnings, which have been burned free of oil and moisture. In German practice, the chlorina tors are agitated 10,000-liter lead-lined vessels, and ferrie chloride is used as the catalyst instead of iron turnings. Fifteen kg of ferrie ohloride is used for each charge of 0000 kg (36) of biphenyl. MONS 049074 Vol.5 CHLOROCARBONS AND CHLOROHYDROCARBONS Raw Materials. The raw material used depends on the type of chlorinated material to be produced; anhydrous chlorine is used os the chlorinating agent in all coses. In general, it can be said that biphenyl alone gives liquid or soft, sticky non crystalline products up to a chlorine content of 00%, low-melting resinous products IK!tween 60 and 65% chlorine content, and partly crystalline or crystalline products of much higher melting points at chlorine contents above 05% (32). In the cose of products that are solid at ordinary temperatures, the higher the proportion of terphenyls or more complex polyphcnyls in the mixture before chlorination, the higher the softening point and the less the crystallizing tendency of the chlorinated product after distillation. For those products that are solid or partly crystalline at room temperature, the higher the chlorine content, the higher the softening point, and the greater the tendency of the material to crystallise (34). Preparation of Crude Chlorinated Biphenyl. For the manufacture of any given grade of chlorinated biphenyl, the chlorin&tor is charged with the proper raw material or mixture of raw materials to give the desired product in an amount sufficient to. cover the catalyst bed and to permit circulation. Then the flow of vaporized chlorine is started and tho charge is circulated with the pump. Throughout the chlorination, tho tomperaturo is kept well above the melting point of the mixture, but below 150C, to avoid excessive sublimation and plugging of the line discharging the hydrogen chloride produced by the chlorination. Samples arc withdrawn for examination from time to timo until the desired chlorine content has bocn reached. At the lower chlorine contonts, specific gravity measurements are taken using a hydrometer to determine the composition. After the product has become too viscous or has reached too high a melting point for convenient determination of the specific gravity at temperatures below 100'C, tho degree of chlorination is determined by measuring the hold point os the material crystallizes, or by tho ball-and-ring softening-point test (36). The timo required for chlorination is 12 to 36 hr, depending upon the chlorine content of the product. The anhydrous hydrogen chloride, which is evolved during tho chlorinationi, is absorbed in water in equipment of conventional design. Distillation of Crude Products. Although the crude products find some applica tions, for most purposes further purification is necessary to remove the color, and the traces of hydrogon chloride and ferric chloride (32,34,35). The methods of purification are somowhat different for the different types of end products. The high-melting solid products are difficult to distill. Distillation under reduced pressure is particularly difficult as it desirable to keep the boiling point above the solidification point. Generally, these products are distilled in gaa-fired retorts at atmospherio pressure. The distillate is flaked on chilled rolls. From practical considerations of quality and better overall processing efficiency, the liquid and resinous products are distilled at lower temperatures in more conventional equipment under reduced preseure. The crude liquid and resinous products are held at an elevated temperature and blown with dry air for several hours, after whioh a few tenths of 1% of lime or sodium hydrox ide is stirred with the material to react with any remaining hydrogen chloride or ferric ohloride. This is followed by batch distillation under reduced preseure. Complete distillation and mixing of the distillate is necessary in order to obtain uniform material of the desired composition. If increased electrical resistivity is desired, the material is stirred at an elevated temperature with a few tenths of 1% of well-dried fuller's earth and then filtered through paper (35,37). MGNS 049875 294 CHLOUOCAKBONS AND CIILOROIIYDROCARBONS Containers and Shipping The liquid chlorinated biphenyls are packed and shipped in gnlvunijsed-stecl drums or in tank ears constructed of uonrustiug metals such ns aluminum or tincoated metal. The resinous products arc packed and shipped in open-lop galvanizedsteel drums, and the high-melting solid products arc packed and ship|>cci in bags. The railroad shipping classification is Resin Synthetic NOI13N. Health and Safety Factors Prolonged exposure to chlorinated biphenyl vapor evolved at high tempevaluve can lead to systemic toxic effects. Inhalation tests on animals indicate that tho maximum safe concentration of vapor is in the range of 0.5 to 1.0 mg of tho lower chlorinated biphenyl mixtures per cubic meter of air. Tho threshold limits (maxi mum allowable concentration for an eight-hour working day) set by tho American Conference of Governmental Industrial Hygienists arc 1.0 mg of tho lower chlorin ated biphenyl compounds (42% chlorine) per cubic meter of air and 0.5 mg of the more highly chlorinated biphenyl compounds (54% chlorine) per cubic meter of air. When chlorinated biphenyl compounds are used at elevated temperatures, engineering controls must be applied, either by the use of closed systems or by effective local mechanical exhaust ventilation together with general workroom exhaust. Although tho chlorinated biphenyls arc not normally skin irritants, their solvent action can remove natural protective oils and fats, and lead to drying and cracking of the skin. Also, continuous or repeated skin contact with chlorinated biphenyls should be avoided because of the possible occurrence of a condition called "chloracne" (38). Uses Electrical Applications. All of the uses of the chlorinated biphenyls depend on their chemical stability and their physical properties, which may be varied to suit the specific application. One very important use is as dielectric mediums in such applica tions as fluids for transformers and as impregnants for capacitors and condensers (29, 30,39-44). Chlorinated biphenyls, used either alone or in blends with other ma terials such as trichloi obenxeno, meet the need for a fire-resistant dielectric fluid with a high resistivity, a high dielectric strength, a relatively high dielectric constant, and a very low power factor. By replacing hydrocarbon oil with chlorinated biphenyls or mixtures of chlorinated biphenyls with trichlurobenzene, it hgs been possible to redesign equipment with a great reduction in size for tho same capacity and voltage. At the same time, tho fire hazards have been eliminated. See also Dielectrics and piezoelectrics; Insulation, electrical. The maximum dielectric constant of commercial chlorinated biphenyl mixtures at 1000 cycles and 25C is approximately G.0. In recent years, considerable attention has been given to upgrading this property (45-48). Combinations of fractional distillation, chlorination, and isomerization can bo used to obtain dielectric constants of 7.0 or slightly above. Direct synthesis of specific trichlorobiphenyl isomers can be utilized to obtain dielectric constants in the order of 10 (49). Improved analytical techniques, primarily capillary gas chromatography (50), have been of great aid in studying the complex chlorobiphcnyl mixtures. MOMS 049876 Vol.5 CHLOROCARBONS AND CHLOROHYDROCARBONS Other important electrical applications for the chlorinated biphenyls are as impregnants for cotton or asbestos-fiber insulation (51), as constituents of asphalt* base wire-impregnating compounds, and as plastioisers in wire-coating compounds, particularly those containing neoprene, rubber, or combinations of polyvinyl chloride, ethylcellulose, and polyvinyl butyral (52-55). Also, chlorinated biphenyls are em ployed as scaling mediums for electrical insulators and as impregnants for carbon resistors to reduce the influence of moisture. Plastics, Lacquers, Paints, and Varnishes. Chlorinated biphenyls are compatible with most of the oommon plastic materials and resins, and are soluble in paint and varnish oils (29). In combination with asphalt, ethylcellulose, chlorinated rubber, Pliolite (styrene-butadiene copolymer), or other plastic materials, they are used ex tensively in protective coatings for wood, metal, and concrete (38,56,57). In com bination with dioctyl phthalate, they are coplasticizers for polyvinyl chloride compo sitions (29,38). See also Coatings, industrial; Paint. In paints and varnishes the hard resinous chlorinated biphenyls are used to impart Increased hardness to the Aims, and the softer resins are used to give flexi bility. The role of theso materials is similar to that of the oil, except that they do not oxidise and lose flexibility on ageing. In nitrocellulose lacquers, chlorinated bi phenyls are employed either alone or in combination with other plasticisers and resins to Impart increased weather resistance, luster, adhesion, and decreased burning rate (57-60). The hard, white, crystalline chlorinated biphenyls of high melting point are useful as pigments with various plastics (61). Adhesives (qv). The resinous products are used in synthetic adhesive com positions in combination with such base materials as polyvinyl acetate, ethylcellulose, chlorinated rubber, polyvinyl butyral, isoprene-styrene copolymer, and polyisobutylone. Chlorinated biphenyls are used in the preparation of coatings of pressureruptur&ble capsules for adhesive tape (62). Lubricants (qv). Chlorinated biphenyls find application as lubricants under extreme conditions such as highly oxidising conditions, high temperatures, extreme pressures, or submerged locations. Mixtures with other oils to form heavier-thanwater lubricants are used in submerged locations, such as bridge rollers. Lubricants for extreme pressures are made by adding up to 15% of the chlorinated biphenyls to potroleum hydrocarbon oils. Heat-Transfer Media (qv). Chlorinated biphenyls have been used for some time in indirect heating applications (63). Recently, products of this type sold by Mon santo Company under the registered trademark Thenninol have been introduced, which are specifically directed to use as heat-transfer media (64). These fluids are particularly well suited for efficient and safe operation in applications involving flammablo materials where uniform temperatures are roquired and for high-tempera ture (bulk temperatures of 600F) indirect heating. Specifically designed units for such applications are required to prevent local overheating. Miscellaneous Applications. Camauba wax may be extended by blending with chlorinated biphenyl In combination with ceresin and paraffin (29,05). Satisfactory waxes and polishes are prepared without the use of carnauba wax by blending ouricury (liouri) wax with chlorinated biphenyl, ceresin, and paraffin. Chlorinated biphenyls aro ingredients of many fire-resietant compositions. Fire-retarding paints usually oontain antimony oxide or barium sulfate in addition to the chlorinated biphenyl. In making fireproof fiberboard, emulsified chlorinated biphenyl is added to the fiber MONS 049877 290 CHLOROCARBONS AND CHLOROHYDROCAR8ONS stock (66). Modifying waxes are added to chlorinated biphenyl in the preparation of textile-coating materials. In addition to the uses listed above, chlorinated biphenyls are ingredients of somo scaling compounds for use with wood or canvas to give protection against moisture, mildew, or attacks of organisms. They are also used in formulating calking com pounds, powdered metal pastes, some soil-poison and wood-preserving compositions, paper transparentisers, and printing inks. Carbonless reprodueing paper is made by an encapsulation procedure which uses chlorinated biphenyl as part of the formula tion (67) (see Encapsulation). Bibliography "Chlorinated Diplioiiyla1' under "Chlorine Compound*, Organui'' in XCT let ed., Vol. 3, pp. BM-832, by C. F. Booth, Monsanto Chemical Company. 1. F. Beil, J. Chem. Soe. Ul. 2773 (1028). 2. Demselben, Ann. Chem. Liebig 181. 138. 142 (1877). 3. S. H. Zaheer and 8. A. Faaeeh, J. Jnd. Chem. Soc. 21, 27 (1044). 4. M. Oomberg and W. E. Bachmann, J. Am. Chem. Soc. 46, 2343 (1024). 5. ibid., 49,230(1027). 0. G. 8chultf, Ann. Chem. Liebigt 174, 200 (1874). 7. E. Bamberger, Bor. Deal. Chm. Get. 29, 465 (1806). 8. 3. J. Dobbie, J. J. Fox, and A. J. H. Gauge, J. Chem. Soc. 99, 1610 (1011). 0, L. Mascare111, D. Gatti, E. Jona, and V. Leoncini, Gait. Ckim. /to/. 69,808-870 (1929). 10. H. H. Hodgarm, J. Chem. Soc. 149. 746 (1046). U. J. C. Coin, J. Chem. Sec. 85,7 (1904). 12. F. Ullmann, Ann. Chem. Liebiga 232, 64-60 (1004). 13. L. E. Hinkol and D. H. Hey, J. Chem. Soc. 131, 2780-2788 (1028). 14. K. A. 8oarborough and W. A. Waters, J. Chem. Soc. 130,03-04 (1027). 16. T. Crauw, /fee. Trtu>, Chm. 60,763 (1931). 10. W. Blakely and H. A. Scarborough, J. Chem. Soc. 190,3007 (1027). 17. W. Zerweck and C. SehOta, Chem. Abetr.30, 0068* (1042). 18. C. Finxi and V. Bollavita, Gate. Ckim. Ital. 04,335 (1034). 10. Y. 8. Zal'kind and M. V. Belikova, /. Gen. Chem. IJSSH (Kngl. Trunel.) 8,1018(1030). 20. H. ltaudnits with H. B6hm, Her. Deui. Chm. Get. 00,743 (1027). 21. V. Bellavita, Gatt. Ckim. lUd. 05,632 (1035). 22. L. Maacarelii, D. Gatti, and B. Longo, Goa. Chim. llal. 03,064 (1033). 23. F. L. W. Van Rooemalen, Ret. Trot. Chim. 53, 359 (1034). 24. Fr. Fichter and M. Adler, Hd. Chim. Acta 9, 287 (1020). 25. H. Meyer and A. Hofmann, Monatth. Chm. 38, 145 (1017). 20. H. Schmidt and Q. Schulti, Ann. Chm. Liebigt 207, 340 (1881). 27. L. W. Pickett, F. O. Walter, and H. France, J. Am. Chem. Soc. 50,2200(1030). 28. Brit. Pat. 779,221 (July 17, 1957) (to Progii). 20. TheArodor Compounds, booklet, Monsanto Co., St- Louis, Mo. 30. F. M. Clark, Trane. Siedrochem. Soc. 05.59-71 (1034). 31. R. B. MaoMulUn, Chem. Bng. Progr. 44 (3), 163-188 (1048). 32. U.S. Pats. 1,892,307 and 1,892,398 (Deo. 27, 1032), R. L. Jonkine (to Swann Research; re- aaeigned to Moneanto Chemical Co.). 33. U.8. Pal. 3,020,200 (April 10,1902), Robert Thermet and Ludovio Parvi (to SocMtS d'Eleetrochimle D'Electromelallurgie etdes AcWriee Electriques d'Ugine). 34. U.8. Pat. 1,892,400 (Deo. 27, 1932), R. L. Jenkins and J. A. Siksreki (to Swann Research; reassigned to Monsanto Chemical.Co.). 35. J. W. J. Fay and J. H. Richards, "Impregnante Used in German Paper Capacitors," Ojlce Tech. 8m. Pfl Rep!. 76869 (1947); /1/OS (Brtluh /nteUipence Objective* Subcommittee) Final Iiept- 893. 30. "NonmetaiUo Mnteriala'MSTW Sid. B88-&T, Port UUA (1040). 37. U.S. Pat. 1,994,302 (March 12,1936), P. M. Clark (to General Electrio Co.). HONS 049676 YoL 5 CHLOKOCARBONS AND CHLOROHYDROCARBONS 297 38. Aroclor Plasticisers, Tch. Dull. No. PL-306, Monsanto Co., 8t. Louis, Mo., Dae. 1060. 30. L. H. Burahan and S. T. Maunder, Gen. BUc. Rev. 42,236-239 (1039). 40. F. M. Clark, Ind. Eng. Chem. 20, 608-702 (1937). 41. W. Jackson, Proe. Rey. See. (London) Ser. A 153, 158-166 (1035). 42. A. H. White and S. O. Morgan, J. Franklin Inst. 216,635-644 (1933). 43. U.S. Pat. 1,836,180 (Dee. 15, 1031), C. R. McCullough and R. L. Jenkins (to Swann Research; reassigned to Monsanto Chemical Co.). 44. U.8. Pate. 1,031,373 and 1,931,455 (Oct. 17. 1033), F. M. Clark (to General Electric Co.). 45. U.S. Pat. 3,038,107 (June 5, 1062), H. I. Weingarten (to Monsanto Chomical Co.). 40. U.S. Pat. 3,1X18,297 (Dec. 11, 1062), H. I. Woingarten (to Monsanto Chomical Co.). 47. H. I. Weingarten, J. Orp. Chem. 26,4347-4350(1061). 48. Ibut., 27, 2024-2026 (1062). 40. U.S. Pat. 2,077,516 (March 28, 1001), H. I. Weingarten (to Chemical Co.). 50. II. I. Weingarten, W. D. Rose, J. M. Schlatar, and G. Whoelor, Jr., Anal. Chim. Avia 26, 301- 304(1002). 31. U.S. Pat. 1,830,147 (June 14. 1032), J. H. Young (to H. H. Robertson Co ). 02. U.S. Pat. 2,129,107 (Sept. 6,1936), E. W.Troelander and W. C. Wilwn (to Pyroxylin Product*). 63. U.S. Pat. 2,130,264 (Sept. 13,1038), F. M. Clark and J. H. Koenig (to General Electric Co.). 54. U.S. Fei. 2,141,910 (Dee. 27, 1938), W. C. Hayman (to General Electric Co.). 50. U.S. Pat. 2,158,281 (May 16, 1939), J. G. Ford and C. F. Hill (to Weetinghouse Electric and Manufacturing Co.). 50. Aroclor Ruins and Plaslicietrs far Chlorinated Rubber, Toch. Bull. PL-311, Monsanto Co., Kt. Louis, Mo., April 1062. 07. Aroclor Fire Retarding Plasticisers and Modifiers for Bpozy Resins, Tech. Dull. C8-14, Monsanto Cn., 8t. Louis, Mo., Nov. 1060. 58. H. W. Duwron, Paint Teehnol. 2, 25-27 (1037). ' 50. H. A. Gardner and G. G. 8wnrd, Nall. Paint, Varnish Ixtcquer Assoc. Sci. Sec. Circ. Ne. 96, 100-103 (1938). 00. R. L. Jenkins and R. N. Foster, Ind. Eng. Chem. 23, 1362-1305 (1031). 01. U.8. Pat. 2,077,700 (April 20, 1037), E. Klein (to E. I. du Pont de Nemours A Co., Inc.). 62. U.8. Pat. 2,088,461 (June 13,1961), H. J. Eiohel (to National Cash Rogmtar Co.). 03. W. J. Davie and P. G. Benignus, Chem. Eng. Prog. 50,39-42 (1063). 64. Therminol FR Fluid Heat Syeteme, booklet, Monsanto Co., St. Louie, Mo. 65. O. W. Wood, Mfg. Chemist 10 (3), 00-104 (1948). 60. U.S. Pat. 3,030,653 (Fob. 11, 1036), R. Q. Quinn (to International Paper Co.). 07: UJ. Pat. 2,548,306 (April 1051) B. K. Green and R. W. Sandberg (to National Cush Register Co.). 11. L. Huduaho Monsanto Company CHLORINATED NAPHTHALENES Laurent, in 1833, observed that waxlike materials resulted from reaction of ehlorine with naphthalene in the presence of certain catalysts. These chlorination produots wore further studied by Fischer in 1878. It was more than twenty years later, however, that Aylsworth discerned their technological potentialities (1). Chemically and physically, the chlorine derivatives of naphthalene presented investigators with a much more complex problem than the chlorobenzenes. Following Erlonmcyer's establishment of the fused-ring structure of naphthalene in 1800, many years elapsed before many of the theoretically possible chlorination derivatives of the compound were isolated and identified; even today the positions of the substituent ohlorino atoms in all isolated tetrachloro- and pontachloronaphthaionos have not been allocated with certainty (boo Table 1). Physically, the difficulty of isolating isomers from tho mixtures produced by chlorination of naphthalene is such that indirect HONS 049879 STANDARD HANOTACTORINC PROCESS FOR AROCLORS APPIHDIX K - BACKCROPNP INFORMATION The following 1* on up-to-dste (Juno 1, 1966) bibliography of Rooooreh reports on Aroelors: Ashworth, G. V., Xsllsr R. K. Development of Anslytlesl Methods - 19(0 Part 9 - Evaluation of General Electric's Improved Thermal Stability Teat for Pyrsnols. Organic Research St. Louis No. 3033, January 196A (On Aroclor 12A2). Ashworth G. H. at al Analytical Chemistry and Spectroscopy Invaitlgstlons1962 Part 2 - Special Studies. Organic Research St. Louis No. 3067 1/6A (On identification of Aroelors) Argo W. B., Knapp W. G., Gibbs M. E., Soull W. L. Heat Transfer Studies In a Fifty Gallon Glass-lined Jacketed Reactor. Organic Research St. Louis No. 2536 6/21/61 (On Aroclor 12AS) Barkley L. B., Llppnan A. E., Nufer H. L. O-Phanyl-O-14-Nltropheayl nathylphosphooothloate. Ag. Research No. F2 6/15/61 (On Aroclor 125A as a solvent) Blndbsutsl A. J., Fowler L., Koarner H. K., Luebke H. H., Msnno A. L., Trunp H. N., Vogler C. B. Thsmlnol Fluid Vapor Pressure and Thermal Stability Instrument. Organic Research St. Louis No. 2961 7/6/63 (Aroelors and Aroclor 1232) Brook* R. F., Koarner W. R., Spector M. B. IBM 70A Computer Frograa for Thsmlnol Fluid Heat Transfer Coefficients. Organic Research St. Louis No. 290A 9/6/62 (On Aroclor 12A2, 1248, 1254) Bucknall R. W., Campbell D. M. W. Building Manufacture of Santlclser 6A0. Organic Research St. Louis NO. 2440'2/8/60 (On Aroclor 1260) Close H. J., Knapp W. G. Aroclor HDK-1 Pilot Plant Preparation. Organic Research St. Louis No. 3007 11/30/61 (On Aroclor HDK-1 and Aroclor 1132) Cunningham E. F., Densnore D. W., Rinehart V. M. Evaluation of Cheatcal Modifiers for Asphalts. Organic Research No. 2529 1/4/60 (On Aroclor 1232) ' HUNS 049880 apfhhdxx k. 2 Darby J. R., Touchatte H. W., Wangler L. R. Application Work on Praaant Flaatldaara - 1959. Organic Raaaarch St. Louie Ho. 2488 3/21/60 (Aroclora mentioned) Sllanburg G. M. Aaalatanc* to Salat and Devalopnant Dapartaanta on Aroclora, Blphanyl and Ralatad Producta - 1954. Organic Raaaarch Be. Loula No. 2420 1/8/60 (On Arodor 1242, 1248, 1254, 1260, and 5460) gllanburg A. M. 1960 Minor Plant Xnveatlgatlona - Suitability of llphouyl fron Union Carblda aa Raw Matarlal for Arodor Production. Organic Raaaarch St. Loula No. 3133 9/29/64 (On Arodor 1148 and 1248) gllanburg A. M. Naw Dlalactrlca - 1959 and 1960. Organic Raaaarch St. Loula No. 2737 2/22/61 (On Aroclora) gllanburg A. M., Buach W. A. High Dlalactrlc Conatant Arodor. Organic Raaaarch St. Loula No. 2676 12/27/60 (On Arodor 1242) gllanburg A. M., Martan H. L. Exploratory Fluorlnatlon Studlaa of Blphanyl Darlvatlvaa. Organic Raaaarch St. Loula No. 2455 4/19/60 (On Arodor 1260) gllanburg A. M., McHugh K. L. Manufacture of Arodor HDK-1. Organic Raaaarch St. Loula No. P1090 12/28/60 (On Aroclor HDK-1) grlckeon F. B., Sakornbut S. S. Papar Tranaparantlaart - A Lltaratura Survey. Organic Raaaarch St. Loula Ho. 2486 4/4/60 (On Arodor 1260) Fallvall W. F., Raathar L. 0. Final Raport on Flra Ratardanta for Polyaatara, Hpoxlaa, Acryllca and Fhanollca. Organic Raaaarch No. 2855 4/3/62 (On Aroclor 1260) Fraanan R. C., Marco G.. J., Spaxlala A. J. The Preparation of Radio active CP 40294 (0-Phonyl-C14*-P-Nltropheoyl Methylphoephonothloata) Ag. Raaaarch No. 18 8/1/62 (On Aroclor 1242) Gaartnar V. R., Scblala R. M. Chlorinated Diphenyl Ether Dlelectrlca. Central Raaaarch No. 1472 8/7/61 (On Aroclor 1242) M0NS 049881 APPENDIX K -3- Qabura 8. B. Clycldyl Ithwi and Polyether* of BlaphaOol-A, Tatrachloroblaphanol-A and Hydrolyzed Aroclor 1262. Plaatlca Kaiaarch Sprlngflald Ho. 1413, 2/2/37 (Od Aroclor 1262) Crahan F. R., Darby J. R., Mangier L. R. Study of Plaatlclcara la Flaatlaola Fart II. Organic Raaaarch St. Loula Ho. 2648 11/14/60 (On Aroclor 1254) Hatton R. E., Cunninghan E. F., Luabke H. H., Stark L. R. Functional Fluid* Application Raaaarch. Organic Raaaarch St. Loula No. 2472 2/16/60 (On Aroclor*) Hatton R. E., McBvan M., Sand* T. F. Statu* Report on Synthetic Functional Flulda - 1950-66. Organic Davalopnant, Gray* Coaur Ho. 1296 12/29/61 (On Aroclora) Xaowlaa W. S., Snlth T. C. Final Report on Preparation of Farfluorlnatad Conpotind* for Uaa aa Functional Fluid* Fart I. Organic Raaaarch St. Loula Ho. 3176 3/25/65 (On Aroclor 1242 and 1266) Lancay R. C. Induatrial Heat Tranafar Flulda - A Market Study. Organic Davalopnant Crave Coaur Ho. 1266 3/10/61 (On Arocior 1246) Lancay R. C. Utilization of By-product Aroclota fron the HDK-1 Frocaaa. Organic Davalopnant' Crava Coaur Ho. 1263 12/7/60 (On Aroclor 1242, 1248, 1254, 1260, HDK-1,1221) McHugh K. L., Ellanburg A. M. Inproved Aroclor 1242 Frocaaa Studiaa /Aroclor HDK-1/ Organic Raaaarch St. Loula Ho. 2755 3/6/61 (On Aroclor 1132, 1248, 1254, 1260, HDK-1) McHugh K. L., Sullivan J. D. MCS 177. Organic Raaaarch Ho. P1179 5/16/62 (On Aroclor 1134, 1234) McHugh K. L., Sullivan J. D. Tentative Frocaaa for MCS-177. Organic Raaaarch St. Loula Ho. F1234 3/12/63 (On Aroclor 1232) Maatdagh J. J. Flan* Retardant Phenolic Phenolic Varnlaha*. Plaatlc Raaaarch Sprlngflald Ho. 1581 10/14/60 (On Aroclor 5460) Parka R. M. Folynarlta File Market Study - Special Report. Organic Davalopnant Crave Coaur Ho. 1277 7/26/61 (On Aroclor*) HONS 049882 APPENDIX K -4- Tarpstra M. A. Hydrolyxad Aroclor 1268 /Alkaline - Mathanol Hydrolysis/ Organic Research Sc. Louis No. 2583 9/7/60 (On Aroclor 1268) Ellanburg A. M. Assistance to cha Aroclor Production. Phosphorous Research SF 2084 Job No. 171-299 12/31/46 Ellanburg A. M., Fa 1than J. E., Richard* H.B.,Jr. Aroclor 1142, Production, Incraaia In Chlorination Eat*. Phosphorous Raaaarch SF 2790 Job No. 171-1028 7/3/32 Ellanburg A. M. Aroclor 1134, Ranoval of Hydrogan Chlorlda fron Waita Gaia*. Phoaphorou* Raaaarch An. SF 1978 Job No. 207 9/21/45 Ellanburg A. M., Simon* R. A. Aroclor 1142 and 1134 prapn. tram blphanyl by contln. chlorination. Organic Raaaarch SL Fin. 1530 Job No. 3040 6/4/56 Matanar VI. F., Backer T. H. Us* of Standard Raactor* for Making Aroclor 1160. Organic Raaaarch SL Fin. X-1491-IV Job No. 117-1491, IV 4/21/42 Ellanburg A. K., Cleveland T. H. Evaporation Loa* of Aroclor*. Ihoaphorona Raaaarch An. SF 2234 job No. 451 7/14/48 Ellanburg A. M., Richard* E. B., Saar* J. K. Aroclor 1221 and 1242, chlorination with DaHpra CL-alr olxt. Phoaphorou* Raaaarch SF 2673 Job No. 171-790 12/10/51 Durgln C. B., Tranantonl Q. A. Spaclflc Haata of Aroclor* 1221 and 1232 Phoaphorou* Raaaarch SF 2083 1/17/47 Ellanburg A. M., Forbua F. c. Aroclor 1232, Broainatad, Prapn. Phoaphorou* Raaaarch SF 2512 Job No. 171-628 9/13/50 Ellanburg A. M.,Cood R. J., Wad* W. W. Tha Bffacts of Prolonged Raat on tha Elactrlcal Propartlaa of Arodora. Job No. 171-616 12/7/50 Nalluna R. 0., Gruatxanachar E. C. Arodora 1232 and 1248, aa conponanta of hydraulic fluids. Organic Raaaarch SL Fla. 1753 Job'No. 3388 2/14/57 MQNS 049883 APPENDIX K -5 - Kllanburg A. M., Good R. J., Richard* I. B., Jr. Aroclor 1236, DloUeCCle Proportion Fhorphorous Research SF 2612 Job Ho. 171*613 5/21/51 Ellanburg A. H., Forbus F. C., Richards R. B., Jr. Aroclors 1236, 1238, and 1240 for General Rlactrlc Ccupany. Phosphorous Raaaareh SF 2539 Job No. 171-609 12/11/50 Ellanburg A. M., Klaus 1. S. Aroclor 1242, as haat transfer nadlua, Properties. Organic Raaaareh SL Flo 2252 Job No. 3371 3/11/59 gllanburg A. M., Wads W. H. Aroclor 1242, Broailnatad, Prapn. Thoaphoroos Raaaareh SF 2419 Job No. 171-535 12/9/49 Bllehburg A. M., Richards H. B., Jr. Contalnara for Aroclor 1242. Phosphorous Raaaareh SF 2523 Job No. 171-623 11/23/50 gllanburg A. M., Richards H. B., Jr. Containtara for Aroclor 1242. Phosphorous Raaaareh SF 2772 Job No. 171-719 gllanburg A. M., Richard a H. B., Jr. Aroclor 1242, 1254, and 1260, distillation at 20-30M. Hg. Fhoapboroua Raaaareh SF 2694 Job No. 171-1028 j2/13/52 gllanburg A. M. Aroclor 1242, Blactrlc Properties, Under Vaeueea atorage at 75 and 100C. Organic Raaaareh SL Fin. 1849 Job No. 2910 8/2/57 Metsnar W. P., Bahr L. C., Tyler L. D. Aroclor 1242, Poruulatlon, for use aa potential hydraulic fluid. Organic Raaaareh SL Fla. K-1332 Job No. 117-1332 10/21/42 Ruahrveln R. A., Pritchett T. R. Haat Content of Southern A and tha Aroclore. CR Sp. 687 - Job Ho. 4-8063, 4/18/52. gllanburg A. M., Morgan J. F., Wade W. W. Tha Preparation of Aroclor 1244, 1242, 1248, 1254, and P1467 for the General Rlactrlc Coapany. Phosphorous Raaaareh SF 2362 Job No. 171-498 6/2/49 Kaller R. B., Ashworth G. W. Aroclor 1242, High Chloride content, analy sis, Conparlaon of G. B., Waatlnghouaa, and Monsanto Methods. Organic Raaaareh SL Fin. 2188 Job No. 3427 6/24/58 MQNS 049884 APPBNDIX K -6- gllenburg A. M., Good R. J., Wade W. V. Aroelor 1242 and 1254, Affect of light on Ileetric Froptttlti, Phosphorous |iarch Sf 2500 Job No. 171-623 6/23/50 gllenburg A. M. Aroelor 1242, 1248, and 1254, Density and Resistivity Studies. Organic Research SL Fin. 2420 Job No. 2681 1/8/60 Gaertnar V. R., Walngartan H. I. Dielectric Liquids: Foruatloo, Coaposltlon and Iaproveswnt of Aroelor 1242 and 1232. RK. Res. Da. lat 1318 Job No. 9442 1/29/60 gllenburg A. M., Hade N. W. Aroclor-llthlisa stearate elxturaa. Phosphorous Research SP 2496 Job No. 171-614 5/29/50 gllenburg A. M., Wade W. W. Aroelor 1242, Mixture with Sentodex, as hydraulic fluid. Phosphorous Research SF 2497 Job No. 171-530 12/5/49 gllenburg A. M., Carrett L. C., Wade W. W. Aroelor 1242 and 1248 hydraulic fluid flanuablllty tests for the Ford Motor Coupsny. Phosphorous Research SF 2447 Job No. 171-614 2/4/50 gsller R. 8., Keener W. 8., Brackblll C. H., Cecil 0. B., Liveay J., Wllllaus W. D. Aroelor 1242, Mixta, with polyuara, electrical properties of. Organic Research SL Fin. 2314 Job No. 3168 7/6/59 ' Ward D. W. Physical properties of the aroclors 1242, 1248, 1254, and 1260. CR Research Sp 597 Job Hp. 4-8065 11/29/49 gllenburg A. Mi, Ashworth C. W., Marten H. L. Study of the Use of Ferric Chloride as Catalyst for the Production of Aroelor 1242. Organic Research SL Fin. 1842 Job No. 3368 7/12/57 gllenburg A. M., Good R. J., Morgan J. F., Richards H. B., Jr. Utilisation of Airco process for Aroelor production. Phosphorous Research SF 2642 Job No. 171-781 9/28/51 gllenburg A. M., Wade W. W. Prellalnary evaluation of anion exchange resins In the renovel of inorganic chlorides fron Aroclors. Phosphorous Research SF 2349 Job No. 171-535 4/21/49 ' Cleveland T. H., Geaenlnhardt P. G., Powers B. L., Sangulnattl P. A. Aroelor 1242, reaction nedlua for aanufacturlng of tolylene diisocyanate. Phosphorous Research Int. 2943 Job. No. 171-1098 10/21/53 HONS 049885 APPINDIX I 7- Cleveland T. H., Machwart G. M. Areclor 1242, raactlon medium for phenyl isocyanate production. Fhoaphoroua Research SF 2816 Job No. 171-1013 11/25/52 Saunders J. 1 1., Gemeinhardt P. G.( Lisa R. 1., Povara 8. L. Aroelor 1242, raactlon medium for tolylane dliaocyanata. Fhoaphoroua Kaaaarch SF 2699 Job No. 171-720 2/20/52 Ssundars J. 1 1., Clavaland T. H. Aroelor 1242, reaction medium for tolylane dliaocyanata. Fhoaphoroua Reaearch Fin. 2700 Job No. 171-743 2/22/52 Illanburg A. M., Slaone R. A. Resistivity Isgirovement of Aroelor 1242. Organic Reaearch SL Fin. 2096 Job No. 3203 6/6/58 Weddell D. S , Aroelor 1242, rubber availing by. Fhoaphoroua Research Fin. 2082 Job No. 171-308 12/19/46 Cleveland T. H., Davla B. R., Flores Hector, Herndon A. B., Saundara J. H. Aroelor 1242, solvent In prepn. of g-tolylana dliaocyanata. Fhoaphoroua Research Fin. 2547 Job No. 171-603 12/22/50 Illanburg A. M., Merten H. Aroelor 1242 - Study of Unstable Product. Organic Research SL Fin. 1640 Job No. 3269 10/22/56 Illanburg A. M., Good R. J., Richards H. B., Jr. Low Tawparatura dielectrics. Phosphorous Research Int. 2912 Job No. 171-1054 12/2/53 Illanburg A. M., Ashworth G. ., Merten H. L. 1. Aroclors (1242, 1254, 1260), chloride stability of, dependence on process variables. 2. Aroelor 1242, up-grading off-grada product. Organic Research SL Fin. 2072 Job No. 3428 5/4/58 Chadwick D. 1 [., Duncan J. M., Kaufman S., Koegle J. S., Llewellyn G. H., Reate T. Aroelor 1242-tolylenedlieocyanate, llquld-vapor equll. data. Organic Research An Fin. 880 Job No. 171-1101, 117-2669, VII 2/26/54 Illanburg A. M. Aroelor 1248 as a Heat Transfer Medium In a Lauont Forced Circulation Heater. Organic Research SL Fin. 1306 Job No. 2957 3/15/55 MQNS 049886 APPRKDIX K 8 Rllanburg A. M., Richard* H. BJr. Aroclor In gase , Phosphorous Research 8F 2325 Job Ho. 171-1089 10/18/53 Wallace F. P., Spring W. I. Insecticides plus Aroclors. Organic Research CC Fin. 965 Job Ho. 117-2542 4/14/54 Howard R. R., Hulette V. H., Vandeven F. Design and testing of a portable Aroclor heating unit. Organic Research 8L Fin. 238 Job No. 117-2060, II. 8/1/48 Rllanburg A. M , Knight R. R. Treating contaminated Aroclor 1248. Phosphorous Research SF 2342 Job No. 171-451 3/25/49 Rllanburg A. M., Forbus F. C. Aroclor 1248 and Santodax - hydraulic fluid. Phosphorous Research SF 2529 Job No. 171-614 9/7/50 Rllanburg A. M., Morgan J. F. Four point depressants for Aroclor 1248. Phosphorous Research SF 2396 Job No. 171-530 8/9/49 Hatton R. H., Sullivan J. D. Functional Fluids - Application Research (1956-1957). Organic Research SL Fin. 2176 Job No. 3132 10/14/58 Fordyce R. C. Arochlor 1254, as plasticiser for Ceres 226. CR Int. 397 Job Ho. 4004 10/15/43 Rllenburg A. M., Good R. J. Aroclor 1254, coaparlson with Feodor. Phosphorous Research SF 2887 Job No. 171-1075 6/11/53 Rllenburg A. M., Good R. J. Aroclor 1254, coaparlson with Fenclor 54. Phosphorous Research SF 2527 Job No. 171-623 9/6/50 Rllanburg A. M. Galvanised plat* druas versus galvanized hot dipped drums for Aroclor 1254. Phosphorous Research SF 2055 Job No. 171-297 7/18/46 Rllanburg A. M., Good R. J., Knight R. R., Wade W. W. Aroclor 1254 drua storage tests to check power factor change. Phosphorous Research SF 2421 Job No. 171-524 11/30/49 Rllanburg A. M., Richards H> B., Jr. Rffact of exposure to alld steel on electrical properties of Aroclor 1254. Phosphorous Research SF 2771 Job No. 171-71B 5/28/52 MQNS 049887 Appendix K -9- Xllenburg A. M., Knight A. R. CoHplalnt of high power factor of Aroclor 1254. Phosphorous Raaaaxch SF 2355 Job No. 171-524 5/13/49 Bllenburg A. M., Wade H. H. Corroaion inhibitor teat* with Aroclor 1254. Fhoaphoroua Raaaarch SF 2336 Job No. 171-530 3/17/49 Blleoburg A. M., Slcharda H. B., Jr. Aroclor 1254, dlatillatlon at 20caa. Hg. Fhoaphoroua Raaaarch SF 2689 Job NO. 171 1028 1/30/52 Nalluaa R. 0., Argo W. B. Aroclor 1254, haat tranafar atudlaa (rotator). Organic Raaaarch SL Fin. 1906 Job No. 2828 10/23/57 Aah J. R., Danlloff K. B., Dahn H. M. Freparatlon and Taatlng of an KBullion of Chlorinated Rubber and Aroclor 1254. Haat Raaaarch SF 912 Project No. 13012-49-1002 3/28/49 Illenburg A. M., Richarda B. B., Jr. Fhoaphoroua Raaaarch SF 2949 Job No. 171-1075 10/28/53 Kllanburg A. M., Sangulnattl F. A. Aroclor 1254, nixt. with Aroclor 4465, aa waterproofing agent for electrical cablet. Fhoaphoroua Raaaarch Fin. 2027 Job Ho. 171-206 3/8/46 Bllenburg A. M., Richard* H. B., Jr. Mixing Aroclor 1254 with secondary butyl acatate. Phosphorous Research SF 2788 Job No. 171 1029 6/25/52 Bllenburg A. M., Sangulnattl F. A. Aroclor 1254, alxt. with dlbenaothlophene aulfona, dlalactrlc constant. Phosphorous Raaaarch SF 2020 Job No. 171-243 2/8/46 Bllenburg A. M. Aroclor 1254, nlxt. with trlcblorobenzena, co efficient of expansion. Phosphorous Raaaarch SF 2964 Job No. 171-1075 1/18/54 Ruabrwain R. A., Hhlta H. A. Studies on light stability of electrical resistivity of Aroclor 1254. CR Sp. 543 Job No. 4-8065 1/11/49 Bllenburg A. M., Good R. J., Hade H. H. Power factor vs. resistivity of Aroclor 1254. Phosphorous Research SF 2438 Job Bo. 171-623 3/15/50 MONS 049888 APPENDIX C -10- Matmar W. p. Aroclor 1234, recovery from saaple coocaalnatad with mineral oil dielectric. Organic Rasaarch SL Pin. Z-1334-1I Job No. 117-1334, IX 4/23/42 Ellanburg A. M., Good X. J., Richard* H. B., Jr. Lina Mttarlal Company, Milwaukee, Wisconsin, complaint on Aroclor 1234 (Elamsx). Fhoaphoroua Rasaarch SP 2511 Job No. 171-614 9/12/30 Hubbard H. L., Mltoray J. P. Aroclor 1260, color of, lnvastlgn. Organic Raaaarch SL Pin. 1370 Job No. 2319 7/19/36 Ellanburg A. M., Martan B. L. Aroclor 1260, fluorlnatlon of. Organic Raaaarch SL Pin 2455 Job No. 3199 4/19/60 Ellanburg A. M., Knight R. R. Aroclor 1260, alxta. with trl-(2-athslhaxyl)- and trloctyl silicon fluorldas, dlalac, prop*. Phosphorous Rasaarch SP2376 Job No. 171-532 7/12/49 Ellanburg A. M., Richards R. B., Jr. Aroclor Investigation on dlffaranca batwaan Anniston and Krussarlch Aroclor 1260. Phosphorous Rasaarch SP 2881 Job No. 171-1088 3/6/33 Hubbard H. L., Brooks R. P. Aroclor 1260, viscosity and Rsfr. Indan studlas, comparison batwaan Anniston and NCR. Organic Rasaarch SL Pin. 2118 Job No. 2602 7/16/S8 Darby J. R., Cannon J. A. Aroclor 1262, as plasticiser for Saran, grain. Organic Rasaarch SL Pin. 2379 Job No. 3591, IP 10/26/39 Drum M. P., Gabura S. E. Aroclor 1262, hydrolysad, glyddyl athars of. PI Raa Spf Pin. 1413 Job No. 1845 2/2/57 Nallma. R. 0., Tarpstra H. A.> Goss J. C., Lynch D. K. Pilot Plant Preparation of Hydrolysed Aroclor No. 1262. Organic Rasaarch SL Pin. 1335 Job No. 3036 11/14/55 Ellanburg A. M., Hade H. W. Aroclor 1268, hydrolysis to haxachlorodlhydroxyblphanyl. Phosphorous Rasaarch SP 2317 HONS 049889 umDn k li Sharp 0. B., Dazsl J., Gabbert J. D., LaBlanc J. R. Hydrolysis of Aroclor 1268 In Mathanollc Sodtun Hydroxide. U Raaaareh Da Fin. 1061 Job No. 9411 7/11/57 Tarpatra M. A. Hydrolysed Aroclor 1268 (Alkaline-Methanol Bydrolysla). Organic Kasaarch SL Fin. 2585 Job No. 3502 9/7/60 Knapp U. G., Cooper R. L., Tandavan F. Pilot Plant Praparation of Bydrolyaad Aroclor 1268. Organic Raaaareh SL Fin. 2334 Job No. 3899 8/17/59 Nalluaa R. 0., Tarpatra M. A., Goaa J. C., Lynch D. K. Pilot Plant Praparation of Hydrolyzed Aroclor No. 1268. Organic Raaaareh SL Fin. 1528 Job No. 3093 5/29/56 Adana J. F., Knapp tf. G., Matthews R. L., Vandavan P. Pilot Plant Praparation of Hydrolyaad Aroclor 1268. Organic Raaaareh SL Fin. 2124 Job No. 3665 7/17/58 Cabla C. L. Aroclor 1268, thiolyala product, aa paptlzlng agant for rubbar. Organic Raaaareh Hi SF 7649 Job No. 1550 7/8/57 Jankina R. L., Hatenar N. P. Aroclor 1269, aolublllty taata in various organic aolvants. Organic Raaaareh SL Fin. X-1249-X 6 U Job HOs. 117-1249, I 1/30/40 (Pt. 1) 3/20/40 (Pt. XI) Matsnar W. P., Dobrata B. H. Aroclor 1270 fran B-221-o. Organic Raaaareh SL Fin. 104 Job NO. 117-1533 2/20/46 Lafforga J. U., Salth R. B. Impregnation of wood with Aroclor "4465" and "330". Phosphorous Raaaareh SF 2101 Job No. 171-398 3/17/47 Bogaard T. D., Saundara J. H., Sloconbe R. J. Aroclor 5442, aa plasticizer in residue froa dlatn. of TDT. Phosphorous Raaaareh SF 2403 Job No. 171-523 9/21/49 RUenburg A. M., Ruackert T. C. Muriatic Acid Tower Repairs. 5442. Phosphorous Research An SF 2140 Job NO. 376 10/17/47 Glttlnga L. D., Moose J. E. Aroclor 5460, adhaslvaa fran. Phosphorous Research Fin. 2054 Job Ro. 171-203, 171-298 7/11/46 HONS 049890 APFEHDIX K 12- Crsnsbav R. L., Ellanburg A. M., Morgan J. F., Had* W. W. Investigation of praclpitata fonaatioa in organic solutions containing Aroclor 5460. Phosphorous Rasaarch SF 2492 Job Ho. 171-623 5/22/JO Ellanburg A. M., Richards H. B., Jr. Aroclor 5460 frcn Dow Tarophan D-25. Phosphorous Rasaarch SF 2885 Job Ho. 171-1077 5/12/53 Ellanburg A. M., Vada W. H. Aroclor 5460, aixt. with LI staarata. Phosphorous Rasaarch SF 2496 Job Ho. 171-614 5/29/50 Ellanburg A. M., Richards B. B., Jr. Aroclor 5460, toly, In nlnaral oil. Phosphorous Rasaarph SF 2949 Job Ho. 171-1075 10/28/53 Ellanburg A. M. Solubility of Aroclor 5460. Phosphorous Rasaarch SF 2088 Job Ho. 171-397 2/6/47 Ellanburg A. M., Morgan J. F., Wads W. V. Tha Solubility of Aroclor 5460 in Various Solvants. Phosphorous Rasaarch An 8F 2272 Job Ho. 451 12/9/48 Ellanburg A. M., Richards B. B., Jr. Preparation of a concentrated solution of Aroclor 5460 in xylena. Phosphorous Rasaarch SF 2960 Job Ho. 171-1075 10/28/53 Ellanburg A. M. Investigation of dacanposltion in Aroclor still. Phosphorous Rasaarch SF 2046 Job Ho. 171-299 5/16/46 Nttsnar W. P., Dux land J. R. Aroclors, (1254 and 1260), odor laprovenant, study of. Organic Rasaarch SL Fin. Z-1402-I.il Job Ho. 117-1402, III 12/5/40 Darby J. R., Allan W. G., Cannon J. A., Cowall E. E., Touchatta H. V., Mangier L. R. Aroclors 1262 and 1232, migration studlaa (1956). Organic Rasaarch 8L Fin. 1730 Job Ho. 3129, III 1/22/57 Tarpatra M. A., Lynch D. K. Hydrolysed Aroclora 1262 and 1268 Sanpla Praparatlon. Organic Rasaarch SL Fin. 1706 Job Ho. 3038 1/8/57 M0NS 049891 APPENDIX X -13- Baanatt 0. E-, Sharp D. B., Outl Joachla. Exploratory Aroclor Chenletry. Part I. Bthara by Alcohylyaie. Bydrolyaad Aroclor Darlvatlvaa. KB Raaaarch Da Int. 1181 Job Boa. 4-9261, 4-9310, 9378 8/1/58 Chadwick D. H., Elleuburg A. M., Marshall W. W. Alkylation of Aroclor* for Evaluation a* Extender Plasticiser*. Organic Xasoarch SL 71a. 1184 Job No. 2682 (SL) 171-1042 (An) 1/17/55 Darby J. R., Covall E. B. Application Work on Present Plasticiser* 1953-54 - Flaaoabllity Studio* with tho SPI T**t*r Organic Research SL Pin. 1649 Job No. 2616, XT 11/20/56 Nl*l**n M. L. Aroclor*, a* glowproofar*. CR Pin 572 Job No. 5-8064 7/19/49 Hatton k, E., Cunnlnghan B. P., Luabk* H. W., Stark L. K. Aroclor*, a* Industrial fluid bass stocks, avaln. Organic R*March SL Pin. 2472 Job No. 3505, XX 2/16/60 Matsnar W. P., Durland J. R., Power* E., Lyl** J. M. Gonaral Electric Stability T*st for Aroclor* and trlchlorobonsan*. Organic Research SL Fin. X-1436 Job No. 117-1436 4/17/42 Kyrld** L. F., Craver J. K. Conpatlbilitla* of Aroclor* with Raslns. Organic Research SL Pin. X-1362 Job No. 117-1362 6/4/40 Bllanburg A. M., Saar* J. K. Exploratory Raaaarch Cyanoganatlon of Aroclor*. Organic RasMrch SL Pin. 1677 Job No. 2678 11/18/55 Ruehrwaln R. A., Banyan A. S., Whit* W. A. Degradation of Aroclor*. RE CR Da Int. 833 Job No. 4-4042 7/29/54 Bllanburg A. M., Richard* H. B., Jr. Aroclor In Gaea*. Phosphorous Raaaarch Int. 2892 Job No. 171-1089 6/17/53 MONS 049892 APPIKDIX R -14- Ellenburg, A. M., R. A- Simona - Aroclors, dielectric propartlaa, Organic Reaaaroh gL Fin. 2305 - Haw Dielactrice - 1957 and 1958. Job Ho. 3316, 6/16/59. Sharp, D. B., Joachim Daaal - Exploratory Aroclor Chanlatry Part III. Clyddylatlon of Hydrolyxad Aroclora. Raaaarch RE Da Int 1183, Job Ho. 9411, 10/9/58. Hubbard, E. M., F. R. Short - Determination of tha oxlrana (o-apoxlda) group by hydrochlorination In dloxana. RE CR Da Fin. 943. Job Ho. 9378, 1/30/56. Darby, J. R., R. M. Parka - Preliminary Evaluation of Plaatlelaara - 1954. Part It Tha Intenelve Evaluation of Secondary Plaatlelaara Including the Aroclora. Org Rea 8L Fin. 1281. Job Ho. 2821, I, 5/16/55. Darby, J. R., W. G. Allen, J. A. Cannon, A. Y. Coran, P. R. Graham, L. R. Wangler. Org Raa SL Fin. 1666. Job Ho. 2892, II, 10/28/56. Cravar, J. K., J. Daaal, J. A. Harblg, J. R. LeBlanc, J. Schvandamann. Synthaala and Application Studlea on Hydrolyaad Aroclora and Darlvatlvaa. RE Raa Da Fin. 1115. Job Hoa. 9411, 9411-03-3, 9416-03-3, 12/30/57. Sharp, D. B., Joachim Daaal, J. E. Raton. Exploratory Alcoholyala and Hydrolyala of Chlorinated Aromatlce. RE Rea Da, ST 1175. Job Ho. 9378, 9/9/55. 8harp, D, B., Joachim Daaal, Exploratory Aroclor Chemlatry, Part II. Dlphanola by Hydrolyala. RE Raa Da, Int. 1182. Job Hoa. 9310, 9378, 9411, 5/13/58. DeCarmo, 0, W. 8. Dampeay, C. F. ludvlk, W. E. Spring. Ineeetlclde Special Problama - Comparative Laboratory Evaluation of Hlran, Hlran and Benall, and Hlran and Aroclor 5460 Formulatlona (July 14 to October 12. 1955). Org Raa SL Fin. 1382. Job Ho. 2760, 12/55. Hetanar, H.P., J. R. Durland. Molatura In TCB and Pyranol Mixea. Org Raa SL Fin. X-1508. Job Ho. 117-1508, 3/21/41. Sharp, D. B., Joachim Daaal. Exploratory Aroclor Chamlatry Part V. Hltrogen Darlvatlvaa by Anmonolyala. RE Rea Da Int. 1177, Job Ho. 9411, 8/4/58. MQNS 049893 APPENDIX K -15 Ellenburg, A. M., P. A. Ssnguinettl. Aroclors, operation of hydrogen Chloride abaorpiton tovar. Phoa Kaa An Pin. 1979. Job No. 230, 6/14/45. Jenkins, k. L., W. P. Metzner. Aroclors, prapn. by chlorination of mixtures of diphenyl and high boilers. Org Res SL Pin X-1168-XV. Job Mo. 117-1168, IV. 10/7/40. Kllenburg, A. M., H. L. Marten. Continuous Chlorination of Aroclors Pilot Plant Demonstration. Org. Res. SL Fin. 2036. Job Mo. 3192, 5/7/58. Ellanburg, A. M., J. K. Sears. Aroclors, pyrolysis with HCN, lit. survey. Org Res SL Lit. 1246. Job No. 2680, 4/26/55. Darby, J. R., E. E. Cowell, P. R. Graham, R. M. Parks, P. W. Spink, L. R. Wanglar. Org Ras SL Pin 1523. Job No. 2595, 2563, 5/24/56. Aroclors, stabillsn. MOMS 049894 MONS 049895 7u/ CONFIDENTIAL HONS 049896 sxumro KMonciuuiK nociss w AlOCLOt Anapa .1. - aw crow The continuous chlorlnator operation, uaad for production of Cruda Liquid Aroelora, conilata of four oaaeada flaw chlorlnator* In aarlas. Thu naxlaoa daily production froa the eontlnuoua tyatea la 90,000 pounda. Thara are four batch operated liquid chlorlnatora and one batch operated aolld chlorlnator. Sae following table for tine ejrelaa and batch valghta. The bottleneck In the production of Aroelora la the atlll ayetea. HONS 049897 aboclor nm ctcues > *** ustcttc abdciors 1121 1142 1148 1154 1160 1162 1168* 2565* 4065* 5042* 5060* Chlorioator Charge: Lba. Biphenyl 3,000 3,000 3,000 3,000 3,000 3,000 9,500 7,550 5,850 Santouux C 2,560 Santowsx 1 3,920 9,800 9,500 Approximate Lbs. Chlorine Required to Produce Batch 1,600 4,330 5,560 7,040 9,030 9,600 40,375 37,750 34,620 14,875 28,500 Approximate WelghC of Crude Batch . 3,750 5,080 5,660 6,350 7,160 7,500 22,420 27,000 25,000 16,000 22,900 Approximate Time Required to Produce Batch 6 hr*. 9 hr*. 10 hr*. 13 hrs. 17 hrs. 18 hr* . 20 hr*. 17 hrs. 16 hrs. 9 hrs. 13 hrs *Solid Aroclora HONS 049898 MONS 049899 STANDARD HAHOTACTDRIHC PROCISS rot AROCLORS APPENDIX M - QUALITY CONSIDERATIONS Arocloti for electrical equipment use* oust ba highly pur* with only alight tracaa of contaminant* Two to three drop* of sweat contain anough aalt to reject a dram of Atoclor on ehlorldaa. They mat ba chaalcally atabla and non-corro*lva to a alda varlaty of atructural matariala. Obvloualy, contlnuoua quality control nuat ba maintained during manufacture, packaging, and ahlpplng to aaaura that the cuatoawr la always aatlafled with the performance of our Aroclore. Normal power factor correcting capacltore uaed In air conditioner* contain about tan cant* worth of Aroclor. If tha capacitor ahould explode and eauae a fire, damage aa high aa $20,000 could raault. Thaae capacltore ara daalgned for 12 to 20 year'a Ilf*. Quality Ingredient*, aueh aa Anniston Aroclor, nuat b* uaad to guarantee thla Ilf* a* there la no non-daatractlva procedure for pra-datarmlnlng thla Ufa. Thla vividly llluatrate* the "*s*h- rooming" damage and tha major raaaon for auch lntana* dealr* for quality product* by our cuatomar*. Each aalea lot of Aroclor la analyaad prior to ahlpmant. Pre liminary aamplaa ara analyaad prior to loading In eara, truck*, and/or druma. Tha apec* to b* mat ara given In greater detail In Appendix B. Each Aroclor tank car la thoroughly cleaned before filling to prevent contamination by material left In the ear by tha cuatomar. Example* of the quality control chart* kept by tha laboratory are Included In thla appendix. The chart* are for Aroclor* 12A2 and 5460 (our haavlaet demand product*). All electric grade Aroclor* have control chart* that ara monitored by tb* Laboratory, Quality Control Board, and Production. Thao* eharta ara uaad to apot trend* which would eventually lead to poor quality Aroclor. Baaldaa showing maximum and/or minimum specs on each property, the averages and two algma values ara shown which make It relatively easy to apot both good and bad trend*. Production Is responsible for knowing the caua* and corrective measures to ba taken for any trends toward poorer quality Aroclor*. Export lot* of Aroclor* 1242 and 1254 must mast additional apaca of higher raalatlvltlaa and lower biphenyl content. Aroclor Property Spec. 1242 Biphenyl Resistivity 0.05 X max. 5,000 glga ohm cm min. 1254 Biphenyl Resistivity 0.025X max. 5,000 glga ohm cm min. MUMS 049900 A. --I | --mi-- HONS 049902 i^::777|Pi traffic-.^.:- 3i:l"Li.:T-K:J:j~,.l:..tiIE.T:d-I"7!'- Pi t f i ) - - --^ I IINMMI ~ }.hl '-Trte rEHTFg-H: R^TrTTTFn^}T=rr: HONS 049904 HONS 049905 STANDARD MANUFACTURING PROCESS FOR AROCLORS APPENDIX H - MISCELLANEOUS HONS 049906 MONSANTO POWER FACTOR SYSTEM OPERATING PROCEDURE Written By: Date: Approved for Field: Date: J. G. Bryant October 19, 1968 ''A n i'tV MONS 049907 INDEX Page INTRODUCTION .................................................................. ..................................... 1 INITIAL ASSEMBLY .................................................................................................. 2 INSTRUMENT MODIFICATIONS ............................................................................... 3 CHECK OUT................................................................................................................ Temperature Indicator ............................................................................... 3 3 Heat Exchanger................................................................................ .... . . 4 Components........................................................................................................... 5 Piping System .................................................................................................. 7 INSTALLATION ON PROCESS.................................................................................... 8 INITIAL PROCESS START UP............................................................................... 8 NORMAL OPERATION.................................................................................................. 9 TROUBLE SHOOTING .................................................................................................... 12 No"Power" when power is turned on.....................................................12 "Off Scale" lights will not go off.....................................................12 "Off Scale" lights "chatter" (off and on).................................. 13 Capacitance reading is different on the same fluid. . . 13 Power Factor continues to be too high and quality Is known to be good............................................................................................... 13 Cell Cleaning Procedure ......................................................................... 14 Removing the Cell from the System................................................14- Cleaning the Cell. .................................................................................14 Reassembling ............................................................................................ 16 ATTACHMENTS Monsanto Power Factor System-Diagrams-Bill of Material . , 17 HONS 049908 ATTACHMENTS (Cont'd) page Monsanto In Line Cell.................................................................................... 18 Heat Exchanger Construction ...................................................................... ig Calibration on 500K Thermister..................................................................... 20 API Instruction on Indicating Pyrometer .......................................... 21 Circuit Modifications to OR 1605 for Recorder Attachment. 23 Spare Parts List............................................................................................. 2*t HONS 049909 1 INTRODUCTION: Increasing quality demands on liquid askarels have necessi tated improved refinement techniques and better methods of elec trical property measurement. Recently, more accurate, namely; three terminal electrical measurements with Improved measuring sensitivity have been developed for laboratory measurements. Factory needs went even further. Here, the desire was to have a quick reproducible and reasonably accurate method of quality measurement. The equipment needed to be rugged and either mount on the process or analyze a small side stream,thereby elimina ting the intricate sampling and sample handling methods normally employed for laboratory analysis. Another feature desired was a simple direct read out which could easily be adapted to a re corder. The Monsanto Power Factor System answers all these needs. The system takes a small side stream of askarel (Aroclor) from the process into the instrument, automatically heats the fluid to the measurement temperature of 100C, measures the power factor and returns the sample to the process in three min utes on a continuous basis. The measurements are in picofarads (10-12) and phase angle (power factor) differences as low as , 0.00005. Needless to say, precision Is mandatory. It is very important that the system be precisely connected and properly grounded to obtain an accurate measurement. This compact system was designed to replace the troublesome laboratory power factor measurement used in the past for routine quality control. This MONS 049910 2 system requires no exterior sampling and Is a quick responding to quality changes. The basic measurement system consists or a precision capaci tor, a bridge, and a liquid sample holder. The bridge reads the difference between the reference (precision) capacitor and the unknown (liquid sample). Sinoe these units are set up to read low power factors (good quality), the material supplied to the unit must be of reasonable quality to even make a measurement. INITIAL ASSEMBLY: The Monsanto Power Factor System Is made up of standard components where possible. All the parts are listed on the at tached Bill of Material with their appropriate Identification. The cell, a Monsanto patented design, is manufactured by Bals- baugh Laboratories and installed in the cabinet by Custom Engi neering. All the piping, thermocouple and electrical connections are Installed in the cabinet by Custom Engineering. The elec tronic detector (General Radio Impedance Comparator 1605 AH), the Precision Capacitor (General Radio Type 1422 CB) and the auxiliary cables (item 18 on the bill of material) are shipped directly from General Radio to avoid excessive handling and possible damage to the equipment. Initial assembly requires only the installation of the electronics in the cabinet and con nection to the appropriate terminals. Note: This Is precision equipment so process fluid leaks, dust, and dirt In the system cannot be tolerated. MONS 049911 3 INSTRUMENT MODIFICATIONS: The co-axial cables, tees and ells should come rrom the factory equipped with teflon spacers. If not, the normal plexi glass spacers should be replaced with teflon so the cables can withstand the heat. A GR874 90 ell with teflon insulators should be Installed on top the cell. . If the comparator is to be used on 220 V/50 HZ power, the connections shown on page 43 for Operating Instructions Type 1605A-AH Impedance Comparator must be made. If a recorder is used to log the power factor a precision 50 ohm resistor should be installed across the phase angle dif ference meter. (See circuit for correction for Recorder OR 1605AH.) The same is recommended for capacitance balance recording. The cell and any insulation surrounding it should be re moved from the housing to facilitate'the check out. CHECK OUT: Temperature Indicator The temperature indicator is a small API MOD503 unit for dlreot indication of temperature. Connected to the instrument may be a "shorting" metal clip to prevent damage to the instru ment during transit. If Installed, this must be removed. A stainless steel sheath thermocouple is connected to this pyro meter to complete the measuring circuit. To achieve proper operation, a resistor is attached to one side of the pyrometer. The total resistance (in series) of the thermocouple and the resistor should be 10 ohms. The resistor must be cut until MONS 049912 4 the combination of the thermocouple and the resistor Is 10 ohms. If the Indication Is erroneous, the unit must be replaced. For more detailed procedures, see the API Instruction Manual 955-31, Rev. A. Heat Exchanger (See"Blll of Material") The heat exohanger Is a 110 VAC/60 HZ (or 220 VAC/50 HZ If so equipped) electric heater parallel ten feet of inch OD stain less steel tubing. The control Is a silicone control reclfler (SCR). The sensing unit Is a 500K ohm thermister. It Is very Important that the thermister wires be twisted together. The wires should not be run parallel to any circuits carrying large ourrents or near transformers. The thermister should read around 500K (thousand) ohms at room temperature. Of course, temperature variations give varying resistance. 'The calibrated knob Is for setting the operating temperature of the heat exchanger. The calibration Is as follows; Scale Setting Temperature ("C) 65 53 39 100 35 110 32 120 The other non-callbrated knob Is the maximum voltage setting. To check the heat exchanger; (1) Check the resistance on the thermister. This should be approximately 500 K(1000) ohms. (2) Plug in the power supply. HONS 049913 (3) Set the calibrated knob at 35. 5 (4) Check the output voltage from the SCR (70 volt maximum). Adjust the maximum voltage to read around 70 volts. This adjustment Is made by turning the slotted shaft oontrol In the appropriate direction. Note as the control appro aches the set point, the power Is proportioned so maximum voltage adjustments must be made with the temperature 10*C or less than the set point. (5) Check, the amperage on the heater at full load. The amper age should be about 13 amps. Maximum heat Input should be p 12 watts/ln. Adjust the set point around the temperature and check the proportlng action. If the amperage check falls, disconnect the heater and check the resistance for an open circuit or short. If either occurs, the heater must be replaced. (6) Once the heater functioning Is checked satisfactory, pro ceed with an electronics check. (7) Unplug the power to the heat exchanger to avoid difficulty In the pressure test. Components Unpack the General Radio 1605AH Impedance Comparator and the General Radio Type 1422 Precision Capacitor and Inspect for physical damage. . Open the front and rear doors of the Monsanto Power Factor System case, remove the capacitor retaining case install the MONS 049914 6 capacitor in the case and lock the capacitor In position. Secure the capacitor case to lock the capacitor In place. Next install the deneral Radio 1605AH comparator through the front of the cabi net and plug It Into the power source. Remove the OR 874 plug from the Impedance Comparator (upper most Jack between the "Standard" and "Unknown" terminals) and Insert Into the right side of the GR1422CB capacitor. Install a QR874 co-axlal tee In the position where the GR874 plug was removed from the comparator. Install a 90ell on the other con nection of the OR1422 capacitor. Connect the left side of the co-axlal tee "Standard" to the 90 ell on the Precision capaci tor with one GR874 Patch Cord. Connect the right side of the comparator and the cell with a OR874 Patch Cord and 90*ell. Cut two equal lengths of rubber covered stranded copper wire (18 or 16 gauge). Install a 90* Jack on eaoh end of one wire and in stall one 90* Jack and one small lug on the other wire. Connect the lower left terminal "Standard" to the other Jack plug on the Standard capacitor by the wire with the two Jacks. With the other wire connect the Jack plug to the right plug "Unknown" on the com parator and connect the lug to the outside electrode on the cell. Cut two short ground wires and connect them from the ground termi nal (lower) on the comparator to the case of the capacitor with one and to the piping with the other. It may be necessary to remove the standard capacitor from Its case to secure the ground wire. This should be done with utmost care to avoid damaging the HONS 049915 7 capacitor. (See the top of the Bill or Materials for a schema tic of the electronics.) Reinstall the oell back into the cabinet and replace all connections to the instrument frame. Connect the cell to the instrument (use a OR 90" ell for the top connection), otherwise, the cell must be removed to make the electrical connections. Look the thermocouple in place by inserting it into the cell until the sheath touches the center electrode. Then back off about 3/16 inch and tighten the lock nut. When the thermocouple is re moved, it must never be tightened more than the initial assembly otherwise, the sheath may touch causing a shorting in the measure ment. Connect all piping connections. . Piping System (Leak Test) - Connect dry air or N2 to the inlet on the process line and oonneot a pressure gauge on the outlet. Open the flow control valve and the two shut off valves. Pressurize the system and test for leaks. A leak of more than 2 pslg per 15 min. must be located and stopped. Note: The heat exchanger must not be powered during this test. Once the system checks satisfactory on pressure test, con tinue with Installing the system on the process. MOMS 049916 8 INSTALLATION ON PROCESS (1) Connect the power cord to a power source with a positive ground. (2) Connect the "process In" to a supply source with 30 to 50 pslg driving force to force the sample through the Instru ment . (3) Connect the "process out" to the system to return the mater ial to the process. (For example, across a valve or orifice plate.) (4) Connect the purge line to dry air or Ng. (5) Connect the cooling water Jacket on the top of the Instru ment to a water source. (Note: Except under extreme heat conditions, the cooling water and cooling blower are prob ably not necessary.) (6) Plug the bridge into the power inside the cabinet. The blower and heat exchanger are connected on the terminal block. (7) Set the control on the SCR at 35 and adjust as necessary for adequate control. See Check Out Procedure under "Heat Exchanger" for calibration. The heat exohanger has a built in maximum temperature override so the unit can not over- ' heat. INITIAL PROCESS START UP (1) Turn on the power to the bridge and adjust the bridge ac cording to normal operating procedure (Sue Normal Operation). There Is no process flow, so omit flow instructions. MONS 049917 9 (2) Read and record the capacitance read on the cell. (This is the air capacitance,) (3) Start the process flow through the cell and let the flow level off at 5 gph. Observe the temperature of the fluid on the temperature indicator and as it approaches ioo*C, the measurement is made. (Note: When the unit is started, the off scale lights will come on and the instrument will not read. This is normal and is a built in feature to prevent damaging the unit. Once the proper temperature is reached, proceed according to normal procedures. The normal capacitance balance for Aroclor Bhould be 4.7 times that of air (empty cell). NORMAL OPERATION: With the flow set on 5 gph and the temperature of 100*0, a reading is ready to be taken. Normally, taking a reading - will consist of no more than Just reading the indicators. To set the instrument up to read or to check the system, the follow ing is done: (1) Set the frequency on 100C. The "Power" light should be on and the instrument given 15 minutes to warm up. (2) Set the Impedance Difference Percent on 1. (Note: Any difference from one (lower) makes the Instrument too sensi tive and (higher) it is relatively insensitive.) (3) Cheok the zeroes of the meters by (a) turning the function switch (top center) to either of the zero positions; (b) adjust the thumb-set zero controls on either side until the meters are zeroed. MONS 049918 10 (4) Check the calibration by: (a) Set the function switch on calibrate (the Impedance Difference Percent must remain on 1). (b) Adjust the Cal switch by turning until the "Impedance Difference" reads full scale 10. Note: To avoid confusion In reading the instrument scales, we need to consider the Instrument design. Each meter has two scales which arc plus (+) and minus (-). On the Inside, each meter has range selector with four positions (two with 3's and two with 10's). The top scale on the meters go to 3 which is used to make the reading any time the selector switch Is on a 3 position (3, .3> .03 or .003). The selector switch on the Inside of the Instrument face sets the maximum and the divisions are the Indicated portion of that maximum. (Example: The range, switch (Phase Angle Difference Radians) Is 0.03 and the meter reads 1,4, then the actual reading Is 0.014. The ten scale (lower) Is used only for the ranges having a 1 and Indicates In the same' manner and the upper scale except In divisions of 10.) The "Impedance Difference" can read plus or minus depend ing on whether the unknown is greater or smaller than the standard. (5) Adjust the "phase Angle Difference" to the maximum setting (0.03). (6) Set the function switch on "Operate Guarded". (7) Turn the standard oapacltor until the "off scale" lights go off and the "Impedance Difference" meter balances at MONS 049919 11 zero. Tills Is the total capacitance. The reading for Aroclor 1242 should be about 4.7 (dielectric constant) times the capacitance of the cell empty (clean). Record the capacitance on the standard capacitor drum when the zero Is obtained on the "Impedance Difference" meter. This oan be used to determine any dielectric constant change by merely dividing by the air capacitance. Also a balance value on any other Aroclor or mix can be cal culated by multiplying the dielectric Constance by the air capacitance of the cell. (Note: If everything else has checked out satisfactorily up to this point and the "off scale" lights do not go off, the power factor is greater than 3% for OR 1605 AH and great er than 10^ for the OR 1605A of which are the maximum scalefor the respective units. To extend the range use the equation shown under "Off Scale lights will not go off" and add to the left side of the Instrument instead of the right. (8) If the reading on the "Phase Angle Difference" is low enough to read on the next scale lower, then switch to the lower scale for Improved sensitivity. (Example: If the range selector switch is on 0.03 and the needle reads 0,008, then this would be below 0.01 which is the lower third of the scale. To read more accurately, we adjust the range selector to 0.01 and then the reading is 80 percent of full scale. HONS 049920 13 (3a) If the bridge falls to check out, see the Comparator Manual starting with Page 24 for servicing or else re place the bridge and return the other unit for repair. Before removing a bridge from service, the cable connecttlons must be eliminated as a source of trouble. These oan be visually Inspected for broken connectors etc. and checked with an ohm meter to make sure they are tight. (3b) If the bridge and cables check, then the problem is in the cell. See "Cell Cleaning Procedure". (3o) Make sure the thermocouple sheath Is not touching the center electrode. - "Off Scale" lights "chatter"(off and on): The trouble may be loose terminals In the cable. Check and tighten as necessary. If polystyrene Is used, then replace It with teflon insulators. Make sure the thermocouple Is at' least 0.15 inch away from the center electrode. Capaoltanoe reading Is different on the same fluid: (1) Check the oell for 0 ring failure (See Cell Cleaning pro cedure.). Although the cell contains two sets of rings, it Is possible to experience a failure. Power factor continues to be too high and quality Is known to be good (1) Check Cell for 0 ring failure. (See cell Cleaning Pro cedure. ) MONS 049921 14 Celi Cleaning Procedure (See the reference drawing "Monsanto In Line Cell") (1) Remove the cell carefully from the system. (a) Close off the flow control valve and the shut off valve In the line; (b) Drain the cell Into a beaker (cell volume 130 cC); (0) Disconnect the wiring and remove the cell from the system; (d) Wash and clean up any spilled material. (2) Cleaning the Cell Take the cell to some clean room (safely ventilated for use of acetone) and disassemble: (a) Disassemble the cell by removing nuts 22 or 23 from bolts 21; , (b) Lift the cell apart. The assembly should disassemble into three parts (1) top flange and center electrode (2) outside shell and (3) the lower flange. Rinse all parts thoroughly with cp acetone. (c) Disassemble the top of the cell (1) Remove the outside shield on the OR 874 connector(30) and unscrew the center connection.(28). (2) With the proper size screw driver, remove the hold ing screw(l6). Hold the center electrode In a soft clean paper towel to disassemble. MQNS 049922 15 (3) Inspect the assembly parts and replace as necessary a. Kel F washer (29) b. Teflon spacer (17) c. Outer 0 rings (18) d. Inner 0 rings (19) (4) If the fluid Is between the inner 0 ring and the center electrode, this will cause erroneous read ings and the cause should be eliminated. Fluid between the outer 0 rings does not present any problem since the outer 0 ring is a safety feature. (5) Rinse the entire system with cp acetone, being careful to hold the electrodes with clean, soft paper. (6) Dry the parts in a clean, dry place, preferably heat the electrode to drive off any solvent left on the surface. The electrode surfaces are polished and should be free of any deposition. (7) Reassemble the cell In reverse order while hot (100C) being extremely careful not to touch the electrodes. Also, be especially careful to make sure the 0 rings fit and are carefully in place before tightening the top flange to the center electrode. New 0 rings should be used. However, if the 0 rings swell slightly and must be reused, they can be shrunk by using dry ice. If they are shrunk by this method, the unit must be assembled quickly. MONS 049923 16 (8) Keep the cell clean and dry until reassembly. (3) Reassemble the cell In reverse order except read the caps oltance balance before the process fluid is started and check with previous readings. Resume according to normal operating procedures. HONS 049924 y.J-.C .A..........dateA-IQ-68 U"JEcT..MpjMn.W..fB.r..Eii.JtDir..SMl;en.... CHKO. BY............. DATE............................................... Dtl^rITl*-BillofMatert(ll....... sheet no . ..17....of JOB NO Xtm Mo, Used Msnufscturer Bill of Material _________ Description Identification Svagelok White/ i^gSloil i! i Dili's Svagelok 10 Brooks 11 Brooks Bulk Head Union #1 Series Valve Male Elbow Male Connector Union Union Tee 400-61-316 l-VS-4-316 88:tt:ffl Connector *Male Connecto; Drill for 1/8 thermocouple Rotameter Siilifi6 Tub* 6-15-2- Purge Meter 15SOV-316 SS-1/8" HU (1-10) Panel Mount (CfH ) 12 13 m* V'mmv Si: S23 87&?534514 Thermon Balebau -h Libs API ( Leeds lorlhrup Special Heat Exchanger MOMS Cell Pyrometer Bryant - 500K-SCR Bryant Allied l.C. Jack Plug IS 4 Outlet Plug Mgfal Box & 3 -Wire Cord 18 Electronics ?3fSle*Jb-&el TuM"8 -d- General Radio Impedance Comparator 1605-9961 General Radio Type 1605AH, Rack Model Precision Capacitor 1422-9916 General Radio general Radio enersl Radio UltMll? l?4Tae?0* ELL 0874-9680 8ik-??i6-Teflon 10' Electronic Supply House 90* Jacks Electronic Supply House Rubber Coated Wire 19 Custom Engineering Corp Cabinet Additional l x 1/8" / ^lujlnu^ a 5 1/2 Labels pipe, and two tenon support rings are provided with the cabinet (l) Monsanto Power Factor System f Nitrogen Flow Control Cell Temp. M0NS 049925 MONSANTO IN-LINE CELL 18 MONS 049926 Nomenclature .10 Outside electrode (low) .11 Inner electrode (high) .12 Teflon Insulator 22. Lower lock nut 23. Upper lock nut 2D. Fluid Inlet a Lower guard and bottom Teflon Insulator 25. Fluid outlet 26. Fluid outlet aIS IS. Upper guard and top Electrode screw and center contact Teflon spacer 27. 28. Insert hole fbr thermocouple Inner electrode terminal on GR 87D plug Outer Silicone 0 ring seal 29. Kel F Insulator washer .19. Inner Silicone 0 ring seal 30. Guard connector to OR87D plur 21 Support bolts and guard connection 31. Connector for l/8"tube x 1/8" NPT pipe 32. Outside electrode terminal NnMW HOMS 049927 20 HONS 0 4 9 9 2 9 Itenascagh Material Mantetioa Cubes Thermocouple Wme SA Owaide Posi Nega Type Shaath tive tive Was Wire Ertaoaten Whs BA Ottaade Posi Ty^ Sheath tive Whs NagsUr* Wk*f bowConetantaa J Brown White Red JX Black White Rad CopperConstantaa T Drown Blue Rad TX Blsa Blue Rad Cteonal-Alumal K Brown Yellow Rad KX Yellow Yellow Rad Pt 10* or 13% Rb-Pl ...-- -- sx Oteo Black Red ZERO SETTING Pyrometer* with automatic cold junction compensation have a small coiled bimetallic print which novas tha zero aettiac of the pointer to agree with the interoat temperature of tha mater, h, may need adjustment from tins to time. Tbit is done by timing the zero adjuetment aeraw on tha front of tha pyrometer. Make this adjustment only after tha pyrometerfaaa been in a room with ev*o temperetire for several hours.Disconnect the thermocouple leads end adjust the pointer to read actual room tanperatirs. Recontact the thermocouple leads. ALL THERMOCOUPLE CONNECTIONS MUST BE TIGHT. A LOOSE CON NECTION OR BAD THERMOCOUPLE JUNCTION WILL CAUSE ERRATIC READ IN CS. S3 gs I I N S T R U M E N T S OKI'IIUM. MO MM* IQIULIW mi m wii. nm m uf im r .was smm-is c o. d Hr INSTRUMENTS CO INSTRUCTION MANUAL INDICATING PYROMETERS MOUNTING___ _____________________________________ API pyrometers are balanced fr seemate reading in a normal vertical posi tion raises sptcifted otherwise. All pyrometers labeled "shielded aster** any be used in any type of panel with little or no affect oa calibration. Those labeled "aoo-smgwtic" must be used only on aluminum, plastic, wood or other noo-smgostic panele. They will read low if mounted in a steel penal. Pyrometer* which as labeled "magnetic" me intended for inetelletiou oa Meal panels. A steel compen sating ring is omimlly eupplied where panel material is not specified. Discard tha ring when mounting on a steal panel. If the pyrometer is used oa a non-magnetic panel, the steel ring moat be ueed. Be sire that the slit in the ring is at the top of the meter banal and the ring is pushed aa far forward as it will go. THERMOCOUPLE SELECTION AND CALIBRATION. Each pyrometer is marked on the dial with tbs type of thermocouple and the total external resistance for which it is calibrated. Use of may other type of thermocouple or one with a higher res tetance tbaa marked will result in in correct readings. (Standard thermocouples and thermocouple wire are avail able from API.) All standard pyrometers we calibrated for 10 ohms external thermocouple resistance end are provided with a 10 ohm calibrating resistor bobbin. (Non-standard pyrometers are uaimlly calibrated far the specific exteriml resistance ordered end no resistor bobbin is supplied. )Tbis resistor bobbin must be adjusted so that tbs total rsaistence of tha thermocouple ami tbs bobbin add up to 10 ohms in ordsr to maintain calitmtion ecctmecy. There fore, fer a S foot, 20 gauge, con eonelaaten thermocouple, tha resistance of the thermocouple would be approximately 1.75 ohms and this reaistancr must be subtracted frost tha calibrating bobbin. Each tirn of the wire oa tha resistor bobbin rejreaents 0.S ohme and fir this example, 3H ticas would he removed. The total restateace of the thermocouple plus the resistor bobbin would than add up to 10 ohms. Far other values of thermocouple rsaistence, simply remove more w teas turns to adjust for the total value of external resistsace muted oa the pyrometer dial. Extra 10 ohm raaiator w-JiKtnt may ha entered by port number 251-34. rc *- It is very important that the resietcr wire be properly soldered after adjust- MONS 0 4 9 9 3 0 -NOTE- WHEN THERMOCOUPLESWITH EXTERNAL RESETANCE HtCHER THAN 10 OHIS WILL BE USED. A SPECIAL PYRO>*TER WILL BE REQUIRED. THE USE OF OTHER THAN THERMOCOUPLE WRE FOR LEADS OR EXTE7SI0NS HAY RESULT LN IMPROPER AMBENT COMPENSATION. ABBREVIATED TABLE OF THERMOCOUPLE RESISTANCE* _ Tbe table below lieu the resistance ia oho* psr pair-foct for v*ks typss of commonly used thermocouples for a number cf different gauges of wire. By using this table, it is necsssary only to massive the length cf tbs thermocouple, knowing tbs type end gauge, to determine its apfroximate resistance. (Actual oresirenient of the thermocouple resistance is pre ferred to using tbs table.) Gauge B&S 8 10 12 U 16 18 20 22 2< 26 28 30 OHMS PER PAIR-FOOT Iron/Conatanta n (Type J) Copper/Coontantan (Type T) .0215 .0184 .0341 .0293 .0542 .0486 .0863 .1370 .0741 .1180 .2180 .1870 3570 3980 3510 .4890 .8770 7530 1390 2 220 3.520 1300 1.910 3.000 Chrome l/Alumel (Type K) .0365 .0580 .0922 .1470 .2330 3710 .5900 .9370 1.490 2370 3.770 5.900 *A complete table cf resistance (tw various wire gauges will be seat oo request. CONNECTION OF THERMOCOUPLE Pyromstw are polarity seasilive aadmsst base tbe thermocouple ccmnectsd to the proper teimiaal* to indieate {roperly. OP all API pyrometers. tbe left teramaal Rm the tear) is positive. See Figme 1 far farther clarification. FIGURE 1 TABLE OF THERMOCOUPLE COLOR COOES The followiag table lists polarittat sad color codes for the connonly used thermocouples and sstsnsioa wires. If the thermocouple is not coded <r if there is doubt on the proper connection.the polarity maybe verified by pass ing tbs thermocouple junction tip through a natch flasm momentarily until the meter indicates an increase in tempcretins - Pm best accuracy, tbs extarnsI thermocouple resistance should be sdjurted as outlined to within ne percent if the resistance of the nesstriag circuit (internal resistance plan external resistanceI. For scale spans of 500 degrees or mere, adjustmsnt accuracy should be better than s03 ohms. For scale spans of 300 dtpeea, adjustment accwecy should be better thus :0.2S ohms. fa) ^ Correction for Recorder - CR 1605AH - 5 - 23 24 SPARE PARTS LIST: The best souroe of spare parts is a complete spare cell. Presuming this Isn't practical, the next best approach is to maintain spares on certain critical Items. These items can be obtained directly from; Balsbaugh Laboratories 25 Industrial Park Road South Hlngham, Massachusetts 02043 They are: Item Part No. Description 1 12 or 14 Teflon insulator 2 28 Inner electrode terminal on OR 874 plug 3 16 Eleotrode screw and center contact 4 29 Kel F insulator washer 5 30 Ouard eonneotor to OR 874 plug 6 19 Inner Silicon 0 ring seal (2 pair) 7 18 Outer Sllloon 0 ring seal (2 pair) 8 17 Teflon spacer The other components of the system should operate essentially trouble free. No spare parts are maintained for these. . MONS 049932 HONS 049605 ANNISTv IA PL.'.i M0N3AMT0 C! i\c: l czw.r* ;v HONS 049606 to 1-1 .VVA787/536/AU05/1124/1/FI/aZO 3 DU"LAP V''1STO'? YOUR TELETYPE APPROVALS REQUIRED FOR MANUFACTURING PROCESSES AO TP** J SMITH RES MGR J R DARBY C,JL OR IME/CAUSTIC TPW H CARDER RES :?3R 0 DEGARKO " A YUPy vONSA YTO CO ST LOUIS DC *:336/A, /1124 / HONS 0A9607 ' Detailed Instructions ] Aroclors i APPENDIX IV METHOD OF RUNNING HOLDING POINTS 44. 1. Obtain representative sample of material from sample line at pump discharge line. Catch sample in a pint can. . 2. The receptacle for running the sample is 1" x 4-1/2" Pyrex tube! sealed at one end. The tube is inserted in a square 8*02. bottle t'hich is insulated in the bottom by a layer of 2" asbestos fibre. The tube Is held in place by a large cork. Insulation is used in an effort to keep the Aroclor from cooling too rapidly. 3. Pour the material into the tube until it is filled within 1-1/2" of Che top. 4. Material will probably crystallize In the cold Cube and will have to be melted again. 5. When the material la melted, Insert a suitable thermometer (0-360C.) which Is fitted with a cork to hold It In place. The bulb of the thermometer should be fitted In the center of the sample, care being taken that It is not too close to the side of the tube. 6. Heat the tube to 200C. . place it in the asbestos Jacket, then put It In the bottle. 7. Take readings on the thermometer every 30 seconds. At first the temperature will drop rapidly (4-6C between readings). This drop will decrease and finally come to a stop and stay constant for several readings, or will start to go back up several degrees.8 8. Record the point at which the temperature remains constant or In esse of a rise, the highest point of the rise Is the hold point of the material. HONS 049608 etallfd Instructions Ar odors 45. APPENDIX V METHOD OF RUNNING SOFTENING POINTS 1. Obtain representative sample of material from sample line at discharge of circulating pump. Catch the sample in can lid or Py/ex beaker. 2. Heat ring and sample. 3. Place ring on can lid or metal plate and fill with sample until material stands slightly higher than edge of ring. Fill the ring from the large diameter side. 4. Cool the ring and lid from bottom of the side until sample sets up, being careful not to get any water on top of the sample. 5. Finish cooling by running water on top of the sample after it sets up. 6. Remove filled ring from lid and trim off any material that is on the outside. 7. Make alight indentation on top of the sample in the center of the ring with a heated wire to hold the ball in place. 8. Fill beaker with water or glycerin. a. Use water when expected softening point is under 80C. b* Use glycerin when expected softening point is over 80C. 9. Place the ring in the sample holder, place ball on sample, and put holder in the beaker. 10. Adjust the thermometer in the holder so that the tip of bulb protrudes 1/4" through the hole in the crossbar that holds sample. 11. Place the beaker on a stand with screen under it and set burner under the stand. MGNS 049609 Light burner and adjust to give a temperature rise as shown on the thermometer of 5C, per minute, 13. Bring temperature up 5C. per minute until ball falls through the sample. 14. Record temperature at time ball falls to lower crossbar as the softcninc noint. HONS 049610 MONSANTO COMPANY Sauget, Illinois November 16, 1970 Messrs: J R. Savage - G.O. W. R. Richard - G.O. B. W. Corlew 0. W. Jackson W. C. Engman R. M. McCutchan Technjcal Inlormation Center Vitar Record Center - G.O. W.G.K. Plant Records Process Holders ,2| Tentative Amendment "K" TITLE Tentative Amendment "K" to the Standard Manufacturing Process for the Manufacture of Aroclors, Department 246, dated October, 1966. SUB-TITLE Demonstrate a modified chlorination procedure to determine the effect on the Monsanto and after corrosion stability of Aroclor 1260. PRESENT PRACTICE Chlorination ol Biphenyl to Aroclor 1260 is presently done in the nve batch chiormators. Ferric Chloride (concentration 0.05%i is used as the catalyst. Chlorination is begun at the temperature or the incoming Biphenyl which is about us'C. (+I5*C.). The batch is allowed to heat up to about 140cc. from the heat *of reaction before cooling is begun. This takes about 30 minutes or less. As cooling is started, the batch temperature gradually rises to 150 C. over another 30 minutes. The batch is finished at 150 C. and when finished, pumped to the blow tanks. Total batch time is about ten hours. PROPOSED CHANGES ' A designed experiment will be run on the batch chlonnators in Aroclor 1260 production. The variables to be modified are catalyst charge, temperature at the start of chlorination and chlorination finishing temperature. The variables with the present and proposed settings are listed on page 2. MQNS 049611 Tentative Amendment "K" Aroclors, Department 246 2. PROPOSED CHANGES iCont'd. Varlabie v-/ Level Present Level (+) Level Proposed Level Ferric Chloride Catalyst 0.05% (2 pounds/batchi 0.10% (4 pounds/batch) Temperature At Start Oi Chlorination HOC. 125'C. Chlorination Temperature 150-C. 190C. Other concroilabie variables will remain normal. Individual chlonnator batches will be sampled and laboratory distilled to be analyzed lor Monsanto stability and after corrosion chlorides. JUSTIFICATION Aroclor 1260 being produced at W.G.K. is presently failing the after corrosion chloride and Monsanto stability tests. This experiment is designed to determine whether the three variables being changed afreet the stability mentioned above. SOURCE Of DATA Past research projects have indicated that catalyst concentration, starting temperature and finishing temperature affect Aroclor 1242 stabilities. W.G.K. P.R.&D. reports on project 91370:3794 are examples, Aroclor 1260 is expected to respond in a like manner. SAFETY These conditions have been run in this equipment as recently as three years ago with no safety problems. None are anticipated at this time. QUALITY The quality of this material will be monitored closely to determine the effect of the changes. Normal analytical tests will be made ot the finished goods and disposition will depend on the outcome of these tests. It the material is within specifications, it will be used as noimai Aroclor. If not, a decision will be made by production with Marketing approval as to disposition. MONS 049612 Tentative Amendment "K" Aroclors, Department 246 3. DEMONSTRATION CRITERIA The particular tests to be watched are Monsanto stability and aiter corrosion chlorides. Analysis of the data will be made to determine whether changing the three operating variables had an effect on the stabilities. A decision on permanent changes will depend on how much improvement is made by this test and whether or not an underlying cause is round and can be corrected. Written sms Approved By: yj> U/io/7o Mgr., Bab business Group __________ t-w> Mgr., IR&D Process Technology PROCESS TECHNOLOGY SAFETY REVIEW COMMITTEE Approved By: A /////AsW'C,aLtj Pfoduction Supervisor Date Production Gen. Superintendent Date A Ui/QzJtotr--tthhO Gen. SijjjEtl Tech. Services > Date _______________ Jlfi* ManufactuririA Manager 1 'Date MONS 049613 MONSANTO COMPANY Saugat, Illlnola Auguat 26, 1970 Meiarai J. R. Savage - G.O. H. R. Richard - G.O N. w. Corlaw D. W. Jackaon w. C. Engman R. M. McCutchan Technical Information Center Record Center - G.O. W. G. K. Plant Recorda Process Holders (2) Tentative Amendment "J" TITLE Tentative Amendment "J" to the Standard Manufacturing Proceaa for the Manufacture of Aroolors, Department 246, dated October, 1966.' SUB-TITLE Demonstration of a modified aeration procedure. CHANGES The present blow tanka and the piping to the drowning jet will be modified to reduce stream pollution due to entrained Aroclor from the blow tanks. The air flow from the two batch blow tanka and the continuous blow tank will be combined. This combined flow will be piped to a condensate tank which has a Brink Mist Eliminator on top of it. The Mist Eliminator should remove 99t or more of the mist which will be collected in the condensate tank. The air stream will be piped to the drowning jet to remove HC1. As an aftermath to the equipment addition, a small pressure, (about 10 inches (f.C.) will be put on the blow tanks wnere there is presently a slight vacuum. This necessitates closing the batch blow tanks which are open to the atmosphere. JUSTIFICATION This aqu as much or stream pollution by HONS 049614 Tentative Amendment "J" Aroclors, Department 246 2. SOURCE OF DATA A eimple trap in the blow tank line has been catching about 250 pounds of Aroclor per day that formerly went to the sewer. Also, a Brink Mist Sampler was used to sample the line and indicated an additional 35 pounds per day of mist. SAFETY Rupture discs will be installed on the old batch blow tanks. The burst pressure will be 5 psig. A new vent line will be run to the drowning jet to maintain the chlorinators at atmospheric pressure for catalyst charging. The present vent is to the blow tank and would have resulted in pressure on the chlorinators and a safety hazard to the operator during catalyst charging. QUALITY No change in quality should result from these changes. Condensate from this operation will be used to produce non-electrical grade Aroclors by combining it with present off gas condensate or by separate reworking similar to the present procedures for off-gas condensate. Normal testing will be done on both the normal run Aroclors and the rework from the condensate. DEMONSTRATION CRITERIA Operation with the new Mist Eliminator will continue unless oper ational or quality difficulties result that can be attributed to the Mist Eliminator. ` Written By Approved Byi ke*rcn And Development Date Manager Approved By s -(LtJL ProauA11bnTfupervisor Hr Date Research Safety Review Committee Product Group Superintendent ` Date T.S.D. Grcj(Yp Supe ur T2T ManulaSuriiS? Manager bate sms HONS 049615 MONSANTO COMPANY Sauget, Illinois August 26, 1970 Messrs! J. R. Savage - G.O. W. R. Richard - G.O. B. W. Corlew D. W. Jackson W. C. Engman R. M. McCutchan Technical Information Center Record Center - G.O. W. G. K. Plant Records Process Holders (2) Tentative Amendment "I" TITLE Tentative Amendment "I" to the Standard Manufacturing Process for the Manufacture of Aroclors, Department 246, dated October, 1966. SUB-TITLE Demonstrate that scrap Aroclors returned from customers can be reworked to produce salable product. CHANGES The existing #1 still will be used to distill Aroclors returned from customers. A storage tank will be installed to hold the returned Aroclors and feed the #1 still. The 41 receiver will catch distilled rework. Finished rework will be transferred to either the #7 storage tank (boildown storage) or to the 41 mix tank which will be unused with the absence of Pydraul business. If filtering is necessary, the existing 36" sparkler filter or the Alsop filters to be installed will be used. In no event will the rework material be allowed to contact normal run product. JUSTIFICATION A savings of 16,000 per year can be realized by reworking an anticipated 2M pounds per year of returned scrap. Also, the pollution problem can be reduced by removing the 2H pounds per year of scrap from the environment. SOURCE OF DATA MONS 049616 Functional fluids research is repsonsible for providing the data for the type of reworking necessary to produce salable material. Material found unsuitable for rework will be incinerated. Tentative Amendment "X" Aroclore, Department 246 2. SAFETY This amendment should not create any safety hazards. Operations will be similar to normal Aroclor production. QUALITY The material produced by reworking the returned Aroclor is expected to meet the specifications for Pydraul formulations and will be used as such. DEMONSTRATION CRITERIA Scrap Aroclor will be reworked if Research indicates it is possi ble to produce salable goods by a method within production capabilities. Costs should be held at or below current Aroclor production costs, if attempts at reworkinc will be incinerated. Written Byi Approved By: Research & Development Manager 'Q Date Approved By: Research Safety Review Committee sms MONSANTO COKPAHT ORGANIC CHEMICALS DIVISION ANNISTON, ALABAMA STANDARD MANUFACTURING PROCESS FOR AROCLOR Departmenti 826,08 826.17 Supersedes: Standard Manufacturing Procaaa For Aroclor Iaauad: 10/22/57 Praparad by: M. J. williams Prod. Fori Supervisor: V. R. Raupt Production Supt.: R. C. Moody Iaauad: September, 1966 MOMS 049618 CONFIDENTIAL INFORMATION Thla procaaa la tha proparty of Monaanto Company and tha recipient la reaponelbla for lta eafakaaplng. It contains confidential Information of Monsanto Company which must not be reproduead, revealed to unauthorlaad persona, or sent outside the Company without proper authorisation. Either retain In a secure file or return to the Standards Department. STANDARD MANUFACTURING PROCESS FOR AROCLOR DISTRIBUTION Technical Information Cantar - St. loula Raaaarch Sacurlty File Tachnlcal Production Managar Plant Managar Production Suparlntandant Production Suparvlaor Malntananca Suparlntandant Tachnlcal Sarvlcaa Dapartnant Fllaa Plant Standarda Dapartnant 2 Coplaa 1 Copy 1 Copy 1 Copy 1 Copy 1 Copy 1 Copy 3 Coplaa Kxtraa MONS 049619 STANDARD MANUFACTURING PROCESS FOR AROCLOR TABLE OF CONTENTS SECTION I - SVNOPSIS OF PROCESS SECTION II - FLOW SHEETS SECTION III - PROCESS IN DETAIL A. Batch Liquid Chlorlnators B. Continuous Chlorlnators C. Biphenyl Mix Tank and Feed Tank D. Solid Batch Chlorlnatora E. Blowing Tank Operation F. Liquid 8tills G. Earth Trsetment and Filtration H. Solid Still I. Packaging SECTION IV - COtWENTS ON THE PROCESS APPENDIX - A. Equipment List B. Finished Goode, By-Product, & Raw Material Speciflcatloaa C. Physical Constanta for Finished Goods, Intenedlatee, and Major Raw Materials D. Utilities E. Personnel F. Packaging and Shipping G. Material Balances R. Atmospheric & Stress Discharge & Haste Disposal I. Process Control Procedures J. Safety and Toxicity Data 1 Accident Reports K. Background Information L. Tima Cycles M. Quality Considerations N. Miscellaneous MON5 049620 COMPANY CONFIDENTIAL Distributiont Technical Information Center - St.L (2) Security File - St. Louis J. E. Smith - St. Louis G. L. Jessee J. L. Corder G. W. Miller . H. E. Schulte Technical Services (3) D. Danna - St. Louis (3) Plant Standards Dept. (Extras) APPROVAL OF SAFETY REVIEW COMMITTEE ?/.r H. E..Schulte T. W. Lawrence J. c. Landwehr MONSANTO COMPANY ANNISTON PLANT 13 JAN 71 TENTATIVE AMENDMENT "F" TO AROCLOR STANDARD MANUFACTURING PROCESS Dated Jul 69 TITLE: PRODUCE AROCLOR 5068 OBJECTIVE: To produce Aroclor 5068 in the existing solid Aroclor . system. PRESENT PROCEDURE: - Aroclor 5068 has not been produced in plant equipment before and there has been no previously established procedure to follow. PROPOSED AMENDMENT: Make a test batch of Aroclor 5068 in existing solid Aroclor equipment. The process changes will be conducted as follows: a. Approximately 8500 pounds Santowax R will be chlorinated to 60% by weight chlorine by standard operating procedures. b. At approximately 60% chlorine, 5 pounds more catalyst will be added to the chlorinator to increase chlorine efficiency. As the batch proceeds, this procedure may be repeated to keep chlorine efficiency at an acceptable level. MQNS 049621 Tentative Amendment HPM Aroclor Standard Mfg. Process Dated Jul 69 PROPOSED AMENDMENT: continued 2. c. Chlorine feed rates will be controlled so that the temperature of the batch remains approximately 260#C. to 2B0*C. and free chlorine in the off-gas is kept at a minimum. d. At approximately 65% chlorine by weight and a softening point of 130*C., three or four 50-gallon druns of material will be removed from the chlorinator to be used in pro ducing 5465. e. Throughout the batch from 60% chlorine to 68% chlorine, hourly samples of off-gas and product will be taken to assist in design of a full production system. f. When the softening point of the batch reaches 150*c to 160*C., the chlorine feed will be stopped. g. The batch will be transferred to the blow tank and air blown before being drummed out of the blow tank. h. The product will be allowed to solidify and then will be ground to a powder for shipment to potential customers. SOURCE OP DATA i Anniston PR6D work (letter from G. L. Arnett to Aroclor 5068 file dated 1/11/71). SAFETY* There is one main potential safety problem created by this test. As the weight per cent chlorine increases, the rate of reaction will decrease and free chlorine will be released in the off gee. This free chlorine poses two potential problems : 1. The possibility of chlorine and steel combustion at temperatures above 2504C. in the off gas lines. To cope with this problem, temperatures will be watched closely and water will be sprayed on the lines to cool the steel if needed. 2. The possibility of too much free chlorine being released to the atmos phere. All process variables will be closely watched and controlled to keep the free chlorine released to the atmosphere at a minimum. However, if the free chlorine released to the atmosphere readies an intolerable amount, the test will be discontinued. Tv, MONS 049622 This material is requested by the Textiles Division and they require a softening point of 150*C, and that no line be added to neutralize any entrained KC1, Tentative Amendment Mr" Aroclor Standard Mfg. Process Dated Jul 69 3. EXTENT OF TRIALi A plant test batch will be made the week of January 25, 1971 and the data from this test will be evaluated before any further tests are made. Originated by skd w HONS 049623 Tentative Amendment "F" Aroclor Standard Mfg, Process Datad Jul 69 4. APPROVALS: .Department Supervisor Plant Manager: G.N*-. Millar 7^ ) J. L. Cordar /-#-v Data I-IS-V Data PRSD Group Leader Jsr.LV:J/. Data Research Group Laadar; Master copy signed by 3. VI. Baker J. H. Baker Mgr. of Research a Dev.: Waster copy signed by W. R. Richard H. R. Richard Manufacturing Manager; Master copy signed by J. R. Savage J. R. Savage 1-20-71 1-20-71 Data 1-18-71 Data MONS 049624 COMPANY CONFIDENTIAL y /i Distribution: Tschnicsl Information Center - St.L (2) Security File - St. Louis J. E. Smith - St. Louis I G. L. Jessee ' J. L. Corder \ G. W. Miller \ H. E. Schulte \ Technical Services (3) \D. Danna - St. Louis (3) Vlant Standards Dept. (Extras) APPROVAL OP SAFETY REVIEW COMMITTEE Master signed bv H. E. Schulte H. E. Schulte Master signed by T. W. Lawrence, Jr. T. W. Lawrence Master signed by J. C. Landwehr J. C. Landwehr MONSANTO COMPANY ANNISTON PLANT 13 OCT 70 TENTATIVE AMENDMENT WE" TO AROCLOR STANDARD MANUFACTURING PROCESS Dated Jul 69 TITLE: INCREASE CHLORINATION EFFICIENCY IN THE PRODUCTION OF SOLID AROCLOR 5060 BY USING ALUMINUM CHLORIDE AND/OR POWDERED ALUMINUM METAL AS THE CATALYST. OBJECTIVE: To increase the efficiency of the Aroclor 5060 chlorination to alleviate free chlorine in the by-product hydrogen chloride gas. PRESENT PROCEDUREt Santowax R is preheated to 150C., mixed with 0.05% ferric chloride, and charged to a batch chlorinatox from a weigh tank. Chlorine gas is added until the desired softening point is attained. Both chlorine flow and reaction mass temperature are closely controlled at 3000 #/hr. max. and 250C. max. respectively. It is then transferred to an air blowing tank to remove the hydrogen chloride gas before charging to the still. Vacuum distillation is carried out in the presence of 0.5* lime and then the product is flaked, bagged and drummed for storage before sales. HONS 049625 Tentative Amendment "E" Aroclor Standard Mfg. Process Dated Jul 69 2. PROPOSED AMENDMENT: Santowax R will be chlorinated using 0.05% aluminum chloride and/or powdered aluminum as the catalyst. Die test will be carried out on normal plant batch chlorinationa. The process changes will be conducted as follows: a) 0.05% (approximately 5.5 pounds) of aluminum chloride and/or powdered aluminum will be added to the Santowax R in the charge tank. b) After proceeding with the batch as a normal chlorination batch, immediate improvement in the amount of free chlorine in the product hydrogen chloride off gas should be noted. SOURCE OF DATA: Anniston PR&D Report No. 1 of Job No. 446-507, 1-22-69. SAFETY: Aluminum chloride must be handled so as not to contaminate it with water, because HC1 will be liberated. Powdered aluminum does burn, but under plant conditions will not cause any new safety problems. QUALITY: Chlorinationa using aluminum chloride and/or aluminum metal does slightly change the isomer content of the product. This does not change the final material specifications of the product. However, this slight change in isomer content makes Aroclor 5460 more closely resemble the isomer content of our foreign competi tors, Bayer and Kanegafuchi, and therefore doesn't change any desired properties of our Aroclor 5460. EXTENT OF TRIAL; A drop in the free chlorine should be immediately noticeable; however, the normal six month trial period is requested to assure sufficient time to run further testa after evaluating the first. . Originated by: :kd HONS 049626 Tentative Amendment "E" Aroclor Standard Mfg. Process Dated Jul 69 3 APPROVALS: Department Supervisor: Master signed by G. W. Miller________________ G. W. Miller 10/14/70 Date Production Superintendent: Master signed by j, L. Corder J. L. Corder 10/14/70 Date Plant Manaqer: PR&D Group Leader: Master signed by G. L. Jessee G. L. Jessee Master signed by J. L. Brown J. L. Brown 10/14/70 Date 10/14/70 Date Reaearch Group Leader: Master signed by J. W. Baker J. W. Baker 10/27/70 Date Mgr. of Research a Dev. : Master signed by M. w. Farrar M. W. Farrar 10/20/70 Date Manufacturing Manager: Master signed by J. R. Savaqe J. R. Savage 10/29/70 Date MQNS 049621 COMPANY CONFIDENTIAL /i Distribution: Technical Information Center - St. L(2) Security File - St. Louis J. . Smith - St. Louis G. L. Jessee J. L. Corder G. W. Miller H. E. Schulte Technical Services (3) D. Danna - St. Louis (3) Plant Standards Dept. (Extras) APPROVAL OF SAFETY REVIEW COMMITTEE Master copy signed by H. E. Schulte H. E. Schulte Master copy signed by P, k. Ward P. K. ward Master copy signed for J.C.Landwehr J. C. Landwehr by V.R.H. MONSANTO COMPANY ANNISTON PLANT 17 Jul 70 TENTATIVE AMENDMENT "P" TO AROCLOR STANDARD MANUFACTURING PROCESS Dated Jul 69 TITLE: PRODUCTION OF AROCLOR 5432 OBJECTIVE: To produce Aroclor 5432 in the existing Solid Aroclor system PRESENT PROCEDURE: Aroclor 5432 has not been produced in plant equipment before and there haa been no previously established procedure to follow. PROPOSED AMENDMENT: Follow the standard operating instructions for producing Aroclor 5442 with the following exceptions. Chlorina tion level can be monitored by checking product specific gravity at 90C. To produce a final distilled product within the specified 1.263-1.290 gravity range (30,5-33% chlorine), the chlorinators should be finished between 1.273-1.300 gravity units. HONS 049623 Tentative Amendment "D" Aroclor Standard Mfg. Process Dated Jul 69 SOURCE OF DATE: a) Anniston PR&D Report No. 1 of Job No. 446-515, 5-26-70 b) Letter P. D. Fowlkes to G. L. Arnett on Aroclor 5432 specs 7-15-70 SAFETY: The amended process has no effect on safety of operation. Normal department safety practices will be followed. QUALITY: The following properties will be monitored during chlorination and distillation: a) Crude Aroclor specific gravity, 1.273-1.300 gravity units at 90C. b) Distilled Aroclor specific gravity, 1.263-1.290 gravity units at 90"C. ,2c) Distilled Aroclor color NPA EXTENT OF TRIAL: initial plant demonstration run will be made the last week of Jul '70. normal six month trial period is needed to make any minor spec, changes assure compatibility of Aroclor 5432 with the components of the various clor blends Aroclor 5432 will be used to make. s ls l :kd HONS 049629 Tentative Amendment "D" Aroclor Standard Mfg. Process Dated Jul 69 3. APPROVALS s Department supervisor Master copy signed by G. W, Miller G. W. Miller 7/20/70 Date Production SuperintendentMaster copy signed byH. L williams 7/20/70 H. L. williams Date Plant Manager _________Master copy signed for G.L. Jessee by L.C.L. 7/20/70 G. L. Jeseee Date PRSD Group Leader Master copy signed by J. L. Brown_________ J. La Brown 7/30/70 Date Research Group Leaders MaSty copy signed by J. w. Baker J. W. Baker Mgr. ofResearch a Dev.s ManufacturingManager: Master copy signed by M. W. Farrar M. w. Farrar Master copy signed by J. E. Smith J. E. Smith 7/39/70 Date 7/30/70 Date 7/22/70 Date MOWS 049630 COMPANY CONFIDENTIAL Distribution: Technical Information Center - St.L(2) Security File - St. Louie J. E. Smith - St. Louis G. L. Jessee J. L. Corder G. W. Miller H. E. Schulte Technical Services (3) D. Danna - St. Loui9 (3) Plant Standards Dept. (Extras) APPROVAL OF SAFETY REVIEW COMMITTEE Master copy signed by H. E. Schulte H. E. Schulte Master copy signed by P. K. Ward P. K. ward Master codv signed bv V.R.H. for Landwehr J. C. Landwehr MONSANTO COMPANY ANNISTON PLANT 14 Jul 70 TENTATIVE AMENDMENT "C" TO AROCLOR STANDARD MANUFACTURING PROCESS Dated Jul 69 TITLE s USE SODIUM HYDROXIDE TO PRODUCE LOW COLOR SOLID AROCLOR 5460 OBJECTIVE: To produce Aroclor 5460 with a color less than 1.25 NPA PRESENT PROCEDURE: Santowax R is preheated to 150C., mixed with 0.05% ferric chloride, and charged to a batch chlorinator from a weigh tank. Chlorine gas is added until the desired softening point is attained. Both chlorine flow and reaction mass temperature are closely controlled at 3000 #/hr. max. and 250*C. max. respectively. It is then transferred to an air blowing tank to remove the hydrogen chloride gas before charging to the still. Vacuum distillation is carried out in the presence of 0.5% lime and then the product is flaked, bagged and drummed for storage before salee. MONS 049631 Tentative Amendment C Aroclor Std. Mfg. Process Dated Jul 69 2. PROPOSED AMENDMENTi Aroclor 5460 will be vacuum distilled in the presence of 0.5% lime and up to 2.5% sodium hydroxide. Ilia test will be carried out on the smaller still (no. 4) to minimize the pounds of intermediate color Aroclor 5460 and to minimize the risk (loss of production) of corrosion of caustic on the steel equipment. The distillation step will be modified as follows: a) Air blow 5060 for a minimum of 1 hour b) Charge still and pull vacuum before adding lime and sodium hydroxide c) Vent still and add 250 lbs. of lime and 250 lbs. of flaked sodium hydroxide d) Begin heatup. When temperature reaches 318C. (melting point of sodium hydroxide) in the still, hold temperature for 10 minutes e) After 10 minute hold period, follow normal operating procedure until distillation is complete f) Draw bottoms immediately after every batch. Solidification of sodium hydroxide begins at 318*C. g) Repeat steps a~f using 2.5% (625 lbs.) sodium hydroxide. The system should now be flushed out h) intermediate color 5460 produced during flushing operation will be segregated from normal and low color 5460. It will be blended with darker 5460 to prevent regular customers from receiving this improved color product i) Run up to 10 batches using 625 lbs. of sodium hydroxide. SOURCE OF DATA: . a) Anniston PRSD Report No. 2 of Job No. 446-507, 9-30-69. b) SAFETY: Teletype from 0. Siebert indicates no corrosion problems encountered using sodium hydroxide) dated 5 Dec '69. M0NS 049632 Bottoms will contain hot caustic. Faceshield must be worn when drawing bottoms. Discard drums at plant dump. Standard safety procedures will be used in handling the anhydrous sodium hydroxide. Caustic left in an opened drum after a still has been charged will not be used in the next charge. Wet caustic will not be used at any time during the test to prevent the instantaneous formation of steam upon addition to the still batch (2409C.). ' Tentative Amendment C Aroclor Std. Mfg. Process Dated Jul 69 3. QUALITY! The color and other properties of Aroclor 5460 will be monitored closely during the test. All intermediate color 5460 will be segregated. Montar 5 (bottoms) produced will be checked for alkalinity. Samples of the Santowax R and resultant Aroclor 5460 will be analyzed for effect on caustic treatment on the biphenyl, PCB contents. EXTENT OF TRIAL: Color improvement should be noticeable almost immediately. A one to two week trial should be sufficient to determine whether any further work is required. However, the normal six month trial period is needed to assure sufficient time to run further tests depending on the results of the first test. Master copy signed by Originated byi C. *** Mcllwain V. R. Haupt C. R. Mcllwain and V. R. Haupt APPROVALS: Master copy signed by: Department supervisor G. W. Miller G. W. Miller Production Superintendent J., L. Corder J . L. Corder Plant Manager <?, Jessee bv L.C.L. G. L. Jessee PRSD Group Leader J. L. Brown J. L. Brown Research Group Leader *7- W. Baker J . W. Baker Mar. of Research fi Dev. w. Farrar M. W. Farrar Manufacturing Manager J. E. J. E. Smith MGNS 049633 7/23/70 Date 7/29/70 Date 7/23/70 Date 7/23/70 Data 8/24/70 Date 8/24/70 Date fl/26/70 Date iMasanto mmimmimutiwi p. d. Klnnear - Anniston, AlabaJfc^ <4 MTI 4 ftaraiNt TO July 2, 1969 Aroelor Procsss Tentstlvs Amendment "8" wjUH* *>* V H. 1. Willlam* \ J. C. Landwehr W. R. Haupe G. W. Millar G. L. Arnett W-yre'UU* QWV/vZ-v'7'7' ^ ^;f 1 ' ' < / /< jf/S 7 The Aroelor process tentative amendment to reduce lime content and increase yields in the still has baen approved. A field test of the amendment should now be scheduled. The following are the recommended procedures for running the test: 1. Install the plant's portable recording ammeter to No. 3 still pump to record pump current during test. MZO 2. Segregate No. } .till ayatam from tha raat of the ayatem. All product ahould go to a aeparata atoraga tank for labora tory checking before It la added to the other flnlahed pro duct . 3. Normal atart-up procedure* are to be followed with the following exceptlone: ) 150 lbs. of lime are to be added to the still at start-up. b) The still will then be operated continously until a degradation of color, thermal chlorides, or electrical properties develops. The coil inlet and outlet temperatures and the still pump ammeter should be watched for a possible plug in the coll throughout the test. c) Sample the forward flow from the still every eight (8) hours after the still has run five (5) batches. Have the laboratory test for color and HST. A sampled the product which has been stored in the separate tank should also be sent to the labora tory for color, HST and resistivity before it is pumped to the main storage area. d) Notation of the batch number at which product is off specifi cations must be recorded. HONS 049634 in.i* my, H-O 2- e) Then add 150 lhe. of additional lime to ttlll when product goea off apeeificatIona. f) Continue feed to atlll repeating the above procedures. If the still bottoms become too vicious as indicated by an increaae in still pump current or coll inlet and outlet temperatures, feed should be discontinued and the procedure for boiling down the still should be started. g) When the product goes off specification again, stop the feed to the still. h) Boll down still level to 20% if possible before discarding the bottoms. I) Repeat the entire test procedure three times. J) This terminates the complete test and normal operating procedures should be resumed. P. D. Kinnear Jw MQNS 049635 Monsanto * M tHAMt ft V COMPANY CONFIDENTIAL K. G. Hale - Anniston Plant. WftJtCT OCrCNCNCl TO February 9, 1971 EXTENSION TO TENTATIVE AMENDMENT "C" TO AROCLOR STD. MFG. PROCESS (USE NaOH TO PRODUCE LOW COLOR AROCLOR 5460) See attached Amendment :c Technical Information Center (2)-St.L. Security File - St. L. D. Danna (3) - General Offices Nv. R. Haupt G. L. Arnett Technical Services (3) Plant Standards - Extras G. W. Miller (Dept. Supervisor) J. L. Corder (Production S\:pt.) G. L. Jessee (Plant Manager) . J. L. Brown (PR&D Group Leader) J. W. Baker (Res. Group Leader) - So. 2nd Q. E. Thompson (Res. Group Leader) - G. 0. M. W. Farrar (Mgr. of Research 6 Dev.) - G.O. W. R. Richard (Mgr. of Research & Dev.) - G.O. J, R. Savage (Mfg. Manager) - G.O. H. E. Schulte ) T. V). Lawrence ) Safety Review Committee J. C. Landwehr ) Three plant batches of Low Color 5460 have been completed (one - 9/70, two - 1/71). Operational problems occurred on two of the three batches in the plant while using the previously proposed recommendations for NaOH addition. Problems were related to degasing (dewatering) of the caustic, and an apparent short period of a caustic reaction with evolution of heat. Additional lab studies were completed and another plant run will be neces sary to determine the scope for caustic addition equipment and optimum caustic charges. The following -operating procedures are proposed for future plant runs: 1. Add lime in blow tank. 2. Check for acid in blow tank* 3. Add additional lime and NaOH mixed in blow tank at 250*C. 4. Blow and circulate for mixing. 5. Transfer to still. 6. Pull vacuum down on still. 7. Raise temperature slowly- holding vacuum. 8. Distill as normal after reaching 320C. MQNS 049636 NOTE: Plant batches indicate that lower NaOH concentration may bs used to meet color specs. Future plant tests will use reduced NaOH charges in an attempt to optimize concentrations in the plant. The tentative amendment attached is requested to be extended by six (6) months with the above operating changes. Tentative Amendment "c" Aroclor Std. Mfg. Process changes 2 We will start the plant tests during the Aroclor run beginning 2/17/71 unless we receive adverse comments on the tentative amendment extension by 2/15/71. ` skd Attachment K. G. Hale Process Engineer Technical Services Dept. MONS 049637 HASTE R ...... * ' * I. COP Y Distribution: Technical Information Center Security File - St. Louis 3. E. Smith - St. Louis G. L. Jesses J. L. Corder G. W. Miller H. E. Schulte Technical Services (3) D. Danna - St. Louis (3) Plant Standards Dept. (Extras) St.M2) APPROVAL OF SAFETY REVIEW COMMITTEE 9/. r H. E. Schulte 2jjiLL ________ L P. K. ward MONSANTO COMPANY ANNISTON PLANT 14 Jul 70 TENTATIVE AMENDMENT "C" TO AROCLOR STANDARD MANUFACTURING PROCESS Dated Jul 69 TITLE: USE SODIUM HYDROXIDE TO PRODUCE LOW COLOR SOLID AROCLOR 5460, OBJECTIVE: To produce Aroclor 5460 with a color less than 1.25 NPA PRESENT PROCEDURE: Santowax R is preheated to 150*C., mixed with 0.05% ferric chloride, and charged to a batch chlorinator from a weigh tank. Chlorine gas is added until the dosired softening point is attained. Both chlorine flow and reaction mass temperature are closely controlled at 3000 #/hr. max. and 250*C. max. respectively. It is then transferred to an air blowing tank to remove the hydrogen chloride gas before charging to the still. ' Vacuum distillation is carried out in the presence of 0.5% lime and then the product is flaked, sagged and drummed for storage before sales. MGNS 049638 Tentative Amendment C Aroclor Std. Mfg. Process Dated Jul 69 2. PROPOSED AMENDMENT: Aroclor 5460 will be vacuum distilled in the presence of 0.5% lime and up to 2.5% 6odium hydroxide. - The test will be carried out on the smaller still (No. 4) to minimize the pounds of intermediate color Aroclor 5460 and to minimize the risk (loss of production) of corrosion of caustic on the steel equipment. The distillation step will be modified as follows: a) Air blow 5060 for a minimum of 1 hour b) Charge still and pull vacuum before adding lime and sodium hydroxide c) Vent still and add 250 lbs. of lime and 250 lbs. of flaked sodium hydroxide d) Begin heatup. When temperature reaches 318C, (melting point of sodium hydroxide) in the still, hold temperature for 10 minutes e) After 10 minute hold period, follow normal operating procedure until distillation is complete f) Draw bottoms immediately after every batch. Solidification of sodium hydroxide begins at 318C. g) Rtpeat steps a-f using 2.S% (625 lbs.) sodium hydroxide. The system should now be flushed out h) Intermediate color 5460 produced during flushing operation will be ` segregated from normal and low color 5460. It will be blended with darker 5460 to prevent regular customers from receiving this improved color product i) Run up to 10 batches using 625 lbs. of sodium hydroxide. SOURCE OF DATA: a) Anniston PR6D Report No. 2 of Job No. 446-507, 9-30-69. b) SAFETYi Teletype from 0. Siebert indicates no corrosion problems encountered using sodium hydroxide; dated 5 Dec '69. MGNS 049639 Bottoms will contain hot caustic. Faceshield must be worn when drawing bottoms. Discard drums at plant dump. Standard safety procedures will be used in handling the anhydrous sodium hydroxide. Caustic left in an opened drum after a still has boen charged will not be used in the next charge. Wot caustie will not be used at any time during the test to prevent the instantaneous formation of steam upon addition to the still batch (240C.). Tentative* Amendment C Axoclor Std. Mfg. Process Dated Jul 69 3. QUALITYi The color and other properties of Aroclor 5460 will be monitored closely during the test. All intermediate color 5460 will be segregated. Montar 5 (bottoms) produced will be checked for alkalinity. Samples of the Santowax R and resultant Aroclor 5460 will be analyzed for effect on caustic treatment on the biphenyl, PCB contents.' EXTENT OF TRIAL; , Color improvement should be noticeable almost immediately. A one to two week trial should be sufficient to determine whether any further work is required. However, the normal six month trial period is needed to assure sufficient time to run further tests depending on the results of the first test. Originated byi__(_ /p 7}% tOl'rf'-A___ ( : !L f\-\ C. R. Mcllwain and V. R. Hau'pt APPROVALS t Department Supervisor^ 77'IZ-UrJ;Z- W. Miller Production Superintendent^______ /^\__ . .l<J Plant Manager__________________ i. ,- /Z'f. / G. L/lJessee * PRtD Group Leader L. Brown 77 ? . bate y * he bate --T-f-LxL'JlL 'Date Research Croup,Leader J. W. Baker Mfg. of Research & Development Manufacturing Manager_ M. W. Farrar Q-$ U.:rt `t E. Smith MOMS 049640 Date f/rflnt, Date frfxi-f? O Distribution: Tschnlcsl Information Csntsr - St. Louis (2) Security Fils - St. Louis W. A, Kuhn - St. Louis W. B. Fspagsorgs H. L. WillIsms R. A. Haydel C. K. Eastman Tschnlcsl Sarvlcss (}) D. Dsnns (3) Plant Standards Dapartmsnt (Extras) Approval Of Safety Rtv law Commlttss oM&Z-L- C.Jtt) BUtMtl a MONSANTO COMPANY ANNISTON PLANT April 29, 1969 TENTATIVE AMENDMENT "B" TO AROCLOR STANDARD MANUFACTURING PROCESS Datad: October, 1968 TITLE: Raduca Urns concentration In Liquid Aroclor stills to Increase yields OBJECTIVE: To Increase the Liquid Aroclor yield to 98% by changing the distillation procedure, PRESENT PROCEDURE: . Liquid Aroclors are produced by seal-continuous distillation of tha crude material. A batch Is considered to be 1,000 gallons of distilled product. The present procedure Is to add 250 lbs. of lime to the first betch of each run. The still Is then operated with contlnuoua feed for five batches. At this point 250 lbs. of lime Is again added to the still. The distillation run Is then continued until the tenth betch. Then the feed Is discontinued and the level In the atlll la boiled down to a 201 atlll lavel before the bottoma are discarded. MUNS 049641 -2- PROPOSED AMENDMENT: Th W. C. Krunmrlch Plant presently adds 150 lba. for aach 15 batchaa and runa for )0 batchaa bafora dropping bottoma. Annlaton Plant PR&D work lndlcataa that It la poaaibla to raduca tha lime addition avan furthar than thla. It la propoaad that a plant taat ba conducted to determine how many batchaa can ba dlatlllad bafora lack of lime affacta the product. In thla taat 150 lba. of lima will ba added to tha atlll and product dla tlllad until a degradation of color, thermal chlorldee, or electrical propartlaa davalopa. Then 150 lba. of additional lima will ba addad and tha taat continued until product quality beglna to deteriorate or until tha atlll bottoma become too vlacoua aa noted by IncTeaaed atlll pump current. SOURCE Or DATA: Annlaton PR&D Report No. 1 of Job No. 913.70: 446506; 3/17/69. SAFETY: Tha amended procaaa haa no affect.on aafaty of operation. QUALITY: Tha quality of Aroclor produced will ba monitored eloaaly. No off-grada material will ba allowed In tha atoraga tanka. EXTENT OP TRIAL: Tha propoaad lima concentration will be maintained until tha affacta are noted. Two or three runs should ba sufficient to determine tha maximum number of batches poaaibla without additional lima. Tha test will run for tha normal 6 month trial period, however, to determine long range effacte. Originated by: Jw MONS 049642 -5- APPROVAL Department Supervisor Production Superintendent Plane Manager Reeeerch Meneger Technical Production HanAger R. A. Heydel H. L. UlUlame W. B. Pmpageorge M. E. Qlbbe TaJ. (fiL^Aa^Ayl W. R. Richard# 7aJ. Ai W. A. Kuhn Date S/t/t9 ' D4te Date f VWi,? Date Dace . *7/4,1 Date MONS (H9643 MONSANTO COMPANY Sauget, Illinois May 13, 1969 Messrs: W. A. Kuhn H. C. Carder J. W. Molloy M. E. Gibbs D. 'C. Armstrong Technical Information Center Process Holders (2) Tentative Amendment "G" TITLE Tentative Amendment "G" to the Standard Manufacturing Process for the manufacture of Aroclors, Department 246, dated October, 1966. SUB-TITLE 33^ Demonstrate quality improvement of Aroclor \1254 ,/as measured by stability tests, by use of modified plant conditions. PRESENT PRACTICE . Biphenyl is preheated to 120C, charged to the batch chlorinator, 0.05% ferric chloride is added, and a controlled flow of chlorine is turned on. The reaction mass temperature increases to 150C where it is controlled. When the proper specific gravity of the reaction mass is attained the chlorine flow is stopped. The batch is pumped to an air blown tank where the residual hydrogen chloride is removed. It is then distilled from lime, earth treated and stored for sales. . CHANGES It is the intent of this amendment to permit the demonstration of the effect of iodine as a co-catalyst in the chlorination of biphenyl. It is proposed that 0.05% iodine be added with the ferric chloride. All other conditions would remain the same. MONS 049644 Tentative Amendment "G" Aroclors -2- JUSTIFICATION It is the objective of the Functional Fluids Business Group to produce Aroclor 1242 with a thermal chemical chloride (TCC) test limit of less than 0.1 ppm. The use of the iodine-ferric chloride catalyst system is the only action which has consistantly achieved this goal in the laboratory. No improvement in the stability of plant produced Aroclor 1242 was experienced when iodine co-catalyst was used during four plant tests. It is thought that these failures were due to a masking effect by organic impurities in the chlorine from the Hooker chlorine facilities. These impurities have been reduced since the Hooker shutdown. Aroclor 1254 was chosen because improvements similar to those of Aroclor 1242 have been seen in the lab work. Since plant produced Aroclor 1254 exhibits a higher TCC average compared to Aroclor 1242 (0.64 vs. 0.14 for first quarter 1969), the effect of iodine in the plant should be easy to document. If there is an improve ment in Aroclor 1254 stability, a plant test in the continuous Aroclor 1242 line will be requested. If there is no improvement found in the Aroclor 1254 plant test, no further plant tests or laboratory work will be conducted until it is deemed necessary by the Business Group. SOURCE OF DATA The Process Research group at WGK has extensively investigated iodine as a co-catalyst in the Aroclor chlorination step. Variables investigated have included chlorination temperature, FeCl. content, iodine content and biphenyl variability. All the dataJ indicates iodine improves the thermal chemical stability. The electrical properties are not affected. SAFETY Iodine is a severe irritant to the skin and lungs. Care should be taken to avoid skin contact or inhalation of the vapors. The effect of iodine vapor upon the body is similar to that of chlorine or bromine, but it is more irritating to the lungs. QUALITY The batches made during the plant test will be processed as non electrical grade Aroclor 1254. Laboratory chlorinated material using iodine as co-catalyst meets all specification properties and exhibited excellent stability. . HONS 049645 Tentative Amendment "G Aroclors -3- QUALITY (Cont'd.) Based on off-gas analyses during past iodine tests, the off-gas could contain as much as an average of 1-2 parts per million of iodine. This could result in approximately 1 ppm in the muriatic acid produced in Dept. 218. The acid will be analyzed for iodine and will be sewered if it contains more than 5 ppm; it will be old as industrial grade if it contains from 1 to 5 ppm-and food grade if it contains less than 1 ppm. The test batches will be scheduled with Dept. 236 batches so that no Dept. 246 gas is transferred to Dept. 217. EXTENT OF DEMONSTRATION The demonstration will consist of three consecutive batches from the same chlorinator, each utilizing 0.05% iodine and 0.05% ferric chloride based on biphenyl. At least six normal batches will be taken as baseline. The batches will be sampled at the 1242 and 1254 stage and processed in the laboratory. All four stability tests will be measured for each sample in the analytical section. CRITERIA FOR ACCEPTANCE This amendment is to allow temporary demonstration of modified plant conditions and further demonstration would be necessary before adoption. . Written by: c 'W C. W. Hamlet, Jr: Approved by: Approved by: Manager of Research Date Research Safety Review Committee iUI, . Gen. Sijjpt. )(? (JjWvjAuyna iD Group Leader;/ HONS */*/*/ Date 4$> 049646 1/tM Gen.SupJJ/Technical Services/Date Technical Prod. Manager Date ) COMPAN" '.ONFIDENTIAL Distribution: Taehnleal Information Cantar - 8t. L. (2) Sacurlty Flla H. C. Cardn - G. 0. H, >. Papagaorga V H. L. Willlaaa ^V. R. lUupt C. K. Eastman TSD FUa (?) Plant Standarda Dapartaant (Extras) SAPETY REVIEW COMUTTEE MONSANTO COMPANY ANNISTON, ALABAMA Daeaabar 27, 1967 TENTATIVE AMENDMENT B To AROCLOR STANDARD MANUPACTORINC PROCESS ' Datad Saptaabar 1966 JJJJJ: High Taaparatura Chlorination OBJECTIVEi To propoaa a changa in tha chlorination ataga of tha Liquid Aroclor Procaaa. PRESENT PRACTICEl Cruda liquid Aroclora ara producad by batch chlorination and by a continu ous ohlorlnator oparatlon. This lattar oparatlon consists of four easeada flow chlorlnators la sarlas whara spaclflc lavala of chlorination occur. Thraa factors ara eensldarad critical for tha production of Aroclor 1142 (cruda fora of alactrlcal grada 1212) in tha continuous unit: 1. Tha catalyst baskats provide adaquata contact surfaea 2. Tha taaparatura of tha chlorlnators is hold to bstvaan 140*C, and 170*C. 3. Farrlc chlorlda in tha aaount of .051 (walght) ba presant in tha faad to tha systaa. MONS 049647 PROPOSED AMENDMENT: Laboratory lnvaatlgaelona at tha W, G. Kruaurlch Plant hava ahown tubatantlal quality laprovanent (primarily lowar thermal chanlcal chlorides) by tha uaa of hlghar chlorination temperatures (190"C.) and up to .201 catalyst. W.O.K. TSD raporta No. 1 and No. 2 of Job No. 91370:3794 prasant tha laboratory background. It la proposed to chlorinate In tha contlnuoua ayatem with tha chlorination tanparatura at 190C. In tha last two chlorlnators of tha caacada and with various catalyst concentrations up to .101. SOURCE Of DATA: U. G. Krunairlch TSD Reports 1 and 2 of Job No. 91370:3794. SAFETY: Tha amended procsss has no affect on tha safety of operation, although over* head product loss to tha off-gas collactlon tank aiay bacoaa aavara. QUALITY: Quality of tha Aroclor produced will ba monitored closely. This product will ba sagragatad and aold to previously coamlttad custoaara only. mm of imu- The proposed temperature and catalyst levels will ba ualntalnsd until discernible affects are notad. Length of run will also ba depandent upon sales commitment. A period of six months should ba adequate for tha catalyst/ taaparaturs evaluation. John HacPharson MONS 04964b ) Tentative iHadnat B Aroclor Manufacturing Proceee -3* December 27, 1967 APPROVAL: Department Supervleor TSD Superintendent: ''l/v. R. Haupt Jt)C<rvfaJL----------- Production Superintendent: H. L. Ullllame Plant Manager: W. B. Pepag/orge Reaearch Group Leader: /S/ M. E. Glbbe M. E. Glbbe Reaearch Manager: Technical Production Manager /S/ W. R. Richard W. R. Richard ~~2/ <^3a*~e/' H. C. Carder 2. <3<h Date //f/d Date z/i/tr fKtm Date 1/12/6S Data 1/22/6B Date . //W ^ MONS 099699 Musinto p M ANNKTON,ALABAMA w September 19, 19(7 auwnr i,mi TO POROCEL COLUM TREATMENT FOR AROCLOK 1242 Tentative Amendment A to Aroelor Standard Manufacturing Froceaa H. L. Williams oo. B. C. Cardar - G.O. H. L. Hubbard - So. 2nd N. F. Mualler - So. 2nd W. B. Papageorge H. L. HIIlians L. C. Fuhrmalatar 3. MacPheraon C. K. Eastman T.S.D. File (3) Technical Info. Cantar-St. Louie (2) Tha Porocel Column has bean used Intermittently since May 27, 1967 to treat Aroelor 1242. Results to data thou no decrease In bed activity (20 M giga ohms resistivity) after treating 428 M gals, of 1242. Problame have shown up In trying to maintain this high quality In toraga tanka and than In drums. One storage tank ha* been segregated to accept column treated 1242 only and la presently being upgraded. Uae of the column has shown tha necessity to Improve sampling techniques and devices along with standardising analytical equipment and technique*. The success of the Porocel Column Is such that acceptance of this aisendment Is recommended now Instead of whan tha six months teat period Is up In November 1967. Unless there are any objections by October 1, 1967, the Porocel Column operating Instructions will be Incorporated Into the Aroelor operating Instructions which are presently being up-dated and will be added to tha next revision of tha Standard Manufacturing Process for Aroelor In 1968. ;md MONS 049650 Distribution: Technical Information Center - St. L. (2) Security File H. C. Carder - C.O. W. B. Papageorge H. L. Williams V. R. Haupt C. K. Eastman TSD File (3) Plant Standards Department (Extras) SAFETY REVIEW COMMITTEE Originally signed by E. M. Eisery Originally signed by J. F. Quinn Originally signed by C, W. Rods MONSANTO COMPANY ANNISTON, ALABAMA 18 May 67 TENTATIVE AMENDMENT A To AROCLOR STANDARD MANUFACTURING PROCESS Dated Sept. 1966 TITLE: Packed Bed Treatment of Electrical Grade Aroclors. OBJECTIVE: To propose a change in the refining of liquid electrical grade Aroclors. PRESENT PRACTICE Two still batches (20, 000 lbs.) of Aroclor 1242 are accumulated in the blending tank and 40 pounds (0.2% by weight) of Attapulgus Earth (Attaclay) which has been dried for a period varying from one to twelve hours at a temperature in the range of 100-300C is added to the blend tank. The material is agitated for 3 hours and then filtered. PROPOSED AMENDMENT: HONS 049651 Laboratory investigations at Anniston have shown substantial quality improve ments can be achieved by the use of activated bauxite (Porocel) for earth treatment of liquid Aroclors. Anniston RStD Report No. 9, Job No. 370-322 presents laboratory background. Additional laboratory work demonstrated considerable advantage to a treatment technique using a packed bed of Porocel. Anniston RStD Reports 13 through 15 of Job No. 370- 322 and Report No. 4 of Job No. 370-340 present the laboratory background. It is proposed to treat electrical grade Aroclors 1242 and 1254 by passing still batches through a packed bed of 30-60 mesh Porocel. > -2- SOURCE OF DATA: Anniston R8tD Reporta No. 13 through 15 of Job No. 370- 322 and Report No. 4 of Job No. 370-340 present laboratory background. SAFETY: The amended process has no effect on the safety of operation. QUALITY: Quality of the Aroclor produced will be improved significantly, and will be monitored closely. The higher quality product will be segregated for export sales only. EXTENT OF TRIAL: Still batches will be processed utilizing the activated bauxite to evaluate this process change. The data, and results of the test, will be completely analyzed. A period of six months should be required to evaluate tho electrical grades. Originated by: HUNS 049652 I -3- Tentative Amendment A Aroclor Manufacturing Process 18 May 67 APPROVAL: Department Supervisor: TSD Superintendent: Production Superintendent: s' II V. R. Haupf L.0 , L. C. Fuhrmeistej }/ i/ H. L. Williams >9^b7 Date -r/z/y Date 'Date Plant Manager: Originally signed by W. B. Papageorge 3-31-67 W. B. Papageorge Date Research Croup Leader: Research Manager: Orlalnallv signed bv M. E. Gibbs N, F. Mueller 5-25-67 Date Originally signed by H. L. Hubbard (by J. Quinn) H. L. Hubbard 5-22-67 Date Technical Production Manager: Orizinallv sianed bv H. C. Carder 5-26-67 He C. Carder Date MONS 049653 luntu mhofaoivixm noctss rat innmrm *0909 UCOtP SHUT The dlapoaltfen of tbo laandwanta to tho Standard Manufacturing Fneno dated October 22, 1957 ara aa follows: A B C-tev.#l D K r Iltle or Description Data taelala Pyraaol aada with ltd 12/21/60 with high hydrolysabla chlorides Circulate chlorlnator watarlal 10/22/57 durlat aatira chlorination parlod Vaa of UM Attasorb 5/15/59 Optlwea Lias Concentration 12/31/58 Dae of Undried Barth 1959 Beeyela Bolldown to Still 5/15/59 Dlaaoaltlan Accepted Accepted tajaetad tajaetad Selected tajaetad 0 Buaber of tuna befora Bolldown 6/16/59 tajaetad t Iarth Treat (0.21) Aroelor 1242 9/22/61 Aceaptad at 70-80C. Dry earth at 100- la past 300e or uan as raealwnd i Barth Treat (0.1-0.41) Aroelor 11/15/61 lever Triad 1242 at 50-100C (ta-sabadt) j 2 Blanket Bland Tanks, filtrate 8/29/63 tajaetad teeelvers and Storage Tanka duo to largo loaaaa of H] K-tev.dl taaowa Catalyst Basket froa Chlorlnator to naka Aroelor 5060 7/29/64 Aceaptad I. Optimise Barth Treatment Tlae 6/16/64 Accepted M Illalaate Barth Drying 1/20/65 tajaetad a Increase Hash Slae of Barth 2/5/65 tajaetad 0 Start-Dp of Ho. 9 Solid Aroelor 5/3/65 Aeeaptad Chlorlnator ? Tve<t\ 6^ ^OcLrv' l~z )T.j\bjbb HONS 049654 MQNS 049635 THTCATIVS MANUAL OF OPSRATIONS coNTumoua aroclor chlorinatiw 1142 vHLORDUIICW SWTXOILI Blphonyl with ono-holf pound of dlioolvod ferric ehlorldo for ovary 1,000 poundo of Blphonyl It puaped at a ataady rata from a Blphtnyl food tank through a Atoga eaaeada chlorination to a erudt 1141 Aroclor hold tank. A eonatant rata of Chlorlno la fad to all ehlorlnatora and each ehlorlnator la hold In progreaalvaly hlghar toaperature rangaa. atcTiai ii - carmoous chlorirattob start-op r37 < 1. ehlorlnatora'dr -P> drcud 6- arc each charged irltb 1,000 pounda cf Blphonyl with one and ant-half poonda of ferric ehlorldo fron tht Blphonyl charga tank (naltlng pot). 1. They art chlorinated to tha following 1avail ehlorlnator Tferaturo Final Gravity S 120-130 1.086-1.098 <90*0 s 130-140 1.178-1.190 <90*0 7 140-130 1.262-1.274 <90*0 6 150-160 1.344-1.357 <63*C) 1. Tha nls tank charga la praparad and droppad to tho food tank. 4. Tho nix tank la raleadad with Charge Ho. 2. 1. Hhan tho ehlorlnator chargae are at the right tcaperatura and gravity tho ayatan la twitched to contlnuoua aa followai HQhS 049656 6. The velvet In tha Blphonyl food lino fron tha feed arc act for circulation and for flow thru tha control valve. The by-paaa around the control valva la kept cloaod. Tha control valve la kept cloaod until naadod by catting tho controller -2- t aero (lew. the feed pay la turned oa and tha charge la ataread circulating. Tha Biphenyl feed llna la opened ta Ho. 5 chlorinetor. Tha valva on He* 8 ahould ba eleaad* 7. Each ehlorlnator la aat for flow Into tha bottoa of tha ehlorlnator. All by-paae valvaa on tha ehlarlnatora ara eleaad. OUrriOM: Check that all aa^le valvaa ara eleaad. 6. Tha valva In tha evar flow llna to tha crude Aroclor catch tank la opnad. 9. Tha bottoa valva la chaekad eloaad. 10. Check that tha crude Arcelor catch tank puap la not operating. 11. The Chlorine Plant la notified 30 alnutea prior to changing to eontlnuoue operation. The Chlorine Plant will aet their controle to produce 15-25 pound llna preature. 12. Start tha chlorine flew to Chlerlnatora 5, 8. 7 and 6 at tha opacified pouade par hour faad. (gee table under noraal operatleae) 12. The mweee chlorine to ba given to Chlerlnatora 1, 2, 3 and A. 14. Start tha Biphenyl faad forward by eattlng tha flow controller at tha valva corraependlng to tha chlorine rata, (gee table In noraal oparatlone) 13. Open tha valva In tha feed llna to Ho. 5 ehlorlnator, cheek that tha alternate faad line ta He. 8 la valvad off. 18. The crude 11A2 la puavad aa needed to the blowing tanka. Tha lnchaa and gallene pu^ed are recorded on tha puqp-out ahaat. HONS 04965 7 17. Uhan aneeaa 11A2 la available It la need to eharga chlerlnatora 1, 2, 3, or A for proceaalng to 12A8, 12SA. 1280, 1282, or 1288, Ho eddltlonal eatalyat la added whan tha notarial la panpad directly to another ehlorlnator. Tha normal charge will ba _______ gellone of 11A2. l 3- ex|t in - LOAono at tax taw aid mo tank 1. Cheek Chat bottom valva Is closed. 2. Check that temperature eontrollar li eat at 100c. 3. Charga Biphenyl at follow*: a. notify Biphenyl (till operator whan ready for charge. b. Still aan to aassure Biphenyl taken frow catch tank and hava recorded on data cheat. c. ChiorIn*tor operator on alx tank platfora open* Biphenyl charge line and with agitator off fllle tanka to 50" <800 gal*.) of Biphenyl. A. Start agitator. 5. Add ferric chloride ae follow*: a. kaaove cap frow epara 4" noaala. . b. Ineart catalyet funnel. c. Four 3.3 (3 Iba. 3 os.) of FoClg thru funnel. d. kaplace cap. . 6. Agitata for two hours, or wore, at 100C. 7. The tank has a Hi Alara at 64 lnche* (960 gale.) and a low alarm at 3 laches <200 gals.). 8. When the feed tank level has fad down to 200 gallons which Is 4% Inches on tha lsval gauge, the LOW level alarm will flash on the control board and tha alara will sound at tha Inside and outside alara horn. 200 gallons will allow tha faad to continue for about one hour. Tha full charge fraa the ala tank Is now dropped to the feed tank ae follow*: a. Stop agitator la tha ala tank. MONS 049658 b. Cheek tank level gauge It should read 4^ Inches or less. c. Open 3" plug cock on bottoa of ala tank and allow tank to drain aqpty to tha feed tank. -4- d* Observe Feed Tank level gauge Co detarulna whan the mix tank la wapty. It ehould gain 46 Inches whan the regular charge has been added. e. The feed tank Is provided with a high level alana which will alarm thru the control panel when the tank has reached 59 Inches. o f. The temperature controller on the feed tank Is set to control at 100 C SECTION IV - NORMAL OPERATION WITH POUR CHLORINATORS 1. Set Biphenyl feed at level specified. (See Table No. I) 2. Adjust ell chlorine feed to the same pounds per hour rate. 3. Peed all excess chlorine to Nos. 1, 2, 3, and 4 chlorlnators. 4. Always notify the Chlorine Department of any new change in chlorine demand Give them 30 minutes notice when a scheduled change In chlorine toed Is to be made. 5. Check gravity of each chlorlnator at minute Intervals. 6. Adjust to proper gravity as follows: a. With all chlorlnators at same chlorine feed, adjust Biphenyl feed rate up or down as needed to produce No. 6 over-flow In proper range. (See Table No. 2) Make email adjustments of 0.1 gals, per min. Allow 20 minutes to observe charge before making another adjustment. b. When one chlorlnator produces above or below the other three, make gradual adjustmenta In chlorine feed to bring It In gravity range. CAUTION: Do not adjust Biphenyl feed and Chlorlna feed et the same time. HONS 049659 c. Adjust the chlorlnator to the middle of the temperature range. 7. When the feed tank level reaches 4% Inches on the gauge, the alarm will sound In the control room and the panel alarm will show LOW feed level. Then: a. Drop full charge from the mix tank. b. Recharge the mix tank. TABLE NO. X - FOUR CHLORINATORS ONLY BIPHENYL FEED RATES FOR DIFFERENT CHLORINE FEED RATES CHLORINATOR RATES LBS. PER HOUR BIPHENYL FEED NATES GALS. PER MIN. 350 2.1 400 2.4 450 2.7 500 3.0 550 3.3 600 3.6 650 3.9 700 4.2 750 4.5 800 4.8 850 5.1 900 5.4 950 5.7 1000 6.0 TABLE NO. II - TOUR CHLORINATORS ONLY TEMPERATURE AMU GRAVITY RANGE CHLORINATOR NO. TEMPERATURE RANGE 0VE8PLIW SP.GR. 5 120 - 130 1.086-1.098 (90C) 8 130 - 140 1.178-1.190 (90<\:) 7 140 - 150 1.262-1.274 (90C) 6 150 - 160 1.344-1.357 <65cC) MQNS 049660 5' 8. The crude product ie pumped to the blowing tenk or other ehlorlnetore ee needed. Record amount pumped In Inches end gellons. 9. Record the following data atminute Intervals on the data sheet or whenever any change Is made in conditions of Biphenyl feed or Chlorine rete. a. Record eech Mix Tank dropped In Inches and gallons. b. Record each pushing from the Crude Aroclor Ceteh Tank In inches end gallons. c. Record all data shown on the data sheet. SECTION V - SAFETY The following lteme ere some of the haserda that we must be aware of and have control of when we ere operating the chlorlnators. Thermal Burns 1. Sampling Hear goggles and gloves when taking a hot Aroclor sample. Burns - Luna Irritation 2. High pressure In the chlorlnator resulting In release of HCi, and soswtlmes liquid. Into the chlorlnator area. a. Nay be caused by water getting Into the chlorlnators from Biphenyl or a leak In the coll. - b. From a plugged HC1 line. Burns - Fire 3. Fire e. Fire can result if Biphenyl Is blown or leaks into a gas tank. b. Flra could result from a spark In a hot Biphenyl - air mixture. Well lines are Installed In the mix and catch tank. c. Fires can result from Biphenyl or Aroclor pulling back Into the Chlorine header. MQNS 049661 4. Biphenyl line rupture The Blphanyl line can rupture If it Is allowed to set up and then resulted In a closed line without room for expansion. -65. Sprains - Breaks Careful footing uurt always be obtained before operating the hard to reach valves on the chlorlnators. 6. A safety belt Is requited prior to Inspecting the flame arrestors on Che mix tank or the feed tank. M. J. Williams February 13. 1961 February 13. 1961 MONS 049662 STANDARD MANUFACTURING PROCRSS FOR AROCLOR SYNOPSIS OF PROCESS Aroclora are the reaction produeta (onad by chlorination of llphanyl and/or Tarphanyla ualng Farrle ChlorIda Catalyat. Tha by-product BC1 gae producad la abaorbad In water to produce Muriatic Acid. Crude Aroclora are produced In the chlorlnatore, air bloun, dletllled, earth treated, filtered, and loaded for ahlpuant. Aroelor la a trade naua uead to dlelgnata chlorination produeta of Biphenyl, Tarphanyla, or ialxturaa of tha two. Tha phyaleal propertlaa vary Iron light free-flowing llqulda to cryatalllna and non-cryetalllna aollda. Depending on the degree of chlorination and tha eoapoaltlon of tha raw natarlala, Santevaz B, and ulxturaa of Biphenyl and Santovax K, or Biphenyl and Santevaz C, yield produeta of lncraaalng vlacoalty up to non-cryatalllna realna. A nuaerleal ayatau of noaanclatura, conalatlng of four dlglta, haa bean developed for Identifying tha Aroclora. Tha thouaanda digit danotee tha rav aatarial uead in tha chlorination. Tha figure 1-- lndleataa 1001 technical grade Biphenyl. Tha hundrada digit danotee vhathar or not tha product la dletllled. Tha -1-- lndleataa undietilled, and tha figure -2-- lndleataa dlatlllad. Tha tana and unlta digit denote tha approxlnata percentage of chlorine contained In tha finlahed product. For exaupla, 1260 la a dlatlllad chlori nated Biphenyl containing 60S chlorine. Thera are deviation! froo the above nonenelature vhen Solid Aroclora arc produced. Thaaa are Hated belov: 1-. Aroclora 6065 and 4465 Aroelor 4065 la tha crude and 4465 la obtained by dlatlllatlcn. The etartlng rav natarlal contain* 40X Santovax R and 601 technical Biphenyl. Thla la chlorinated to (SI. 2. Aroclora 5060 and 5460 Aroelor 5060 la tha crude fron which Aroelor 5460 la dlatlllad. Tha atartlng rav natarlal la 1001 Santovax R vhlch la chlorinated to 60S. M0NS 049663 Aroelor Manufacturing Procaaa Synopela of Procaaa 2. 3. Aroelor 3042 and 5442 Aroelor 3042 la tha crude from which Aroelor 3442 la dlatllled. Tha atartlng raw material la 100% Santovax R which la chlorinated to 42%. 4. Aroelor 2565 Thla la an undlatllled product. Tha atartlng raw material conalata of 251 Santowax C and 75% technical Biphenyl. Thla la chlorinated to 65%. Chlorlnator Area Thera era four batch operated liquid chlorinetore, one batch operated aolld chlorlnator, and one contlnuoua oparatad chlorlnator ayatem. Tha contlnuoua ayatem conalata of four batch chlorlnatora caacadad with owarflow from one unit to the next. Tha product from tha laat ataga la tha flnlahed crude Aroelor. Batch oparatad liquid chlorlnatora are charged with 3,000 pounde of Biphenyl with 1-1/2 pounde of ferric Chloride Catalyat. Chargee for tha aolld chlorlnator vary dependant upon the Aroelor to be produced. Chlorine gaa added through a dlatrlbutor plate reacta with tha raw material to raleaae HC1 and heat. Tha HC1 gaa goaa to the Murlatle Acid Department. Heat la taken away by uae of external air cooled heat axehangara. The epeclflc gravity of the crude la checked after chlorine feed haa been on for four houra, again when 80% chlorinated, aa Indicated by alarm, and aa needed thereafter. In the contlnuoua chlorination ayatem. Biphenyl la fad to the flrat atage and chlorinated. Crude Aroelor overflowa to the aecond ataga, etc., until the final product overflowa from the laat ataga. Bach chlorlnator la held at a different level of chlorination with the laat ataga balng the final crude Aroelor daairad. Normally, Aroelor 1142 la produced In thla ayatem. Crude Aroclore from the batch chlorlnatora and tha contlnuoua ayatem are tranaferred to a blowing tank to be air blown for one (1) hour minimum before dletillatlon. HONS 049664 Aroolor Manufacturing Proeaaa Synopela of Proeaaa 3. Still Araa Liquid Aroclora Aaratad Aroclora from a blowing tank or a faad tank ara charged to a atlll, hydrated lima la addad, a vacuum of 720 am Hg <40 M Hg abaoluta) la applied, tha atlll furnace la fired, and the Aroclor la dletilled Into a receiver. Tha dlatlllatlon la emicontlnuoue, alnea tan (10) recelvare are dlatlllad prior to drawing bottoma op realdua from the atlll. Every two racelvera (or approximately 2,000 gallona) ara treated with 40 lbe. of earth for two houra and than filtered. Tha flnlahad product la trantferred to atorage tanka prior to loading Into dtuma or tank care. Solid Aroclora Solid Aroclora are dlatlllad In a almllar manner to Liquid Aroclora except for 1168. Aroclor 116S la not air blown and la charged directly to the atlll from tha chlorlnator. A vacuum of 4 mil abaoluta la applied for dlatlllatlon. 8olld Aroclora have one to four racelvera dlatlllad prior to drawing bottoma In the atlll. Thle la dependent upon tha particular Aroclor being produced. Solid Aroclora are not earth treated or filtered. They are drummed directly from the receiver or are flaked (Aroclora 1268 and 3460). Chemical Eauatlona Liquid Aroclora Baaed on the foraeaetad damande through 1969, the average Liquid Aroclor could be called 1244.7. Biphenyl 134.2 Chlorine 70.9 Tlolde oar CWT Aroclor Chlorine Biphenyl Hydrogen Chloride Aroclor 1244.7 271.5 Hydrogen Chloride 36.3 Theory Standard 89.4 56.5 45.7 96.1 58.2 38.8 M0NS 049665 Areelor Manufacturing Process Synopala of Procsss 4. Solid Aroclora Boood on tho forcesseed demands through 1969, the sverege Solid Aroolor souId contain 60.7X chlorine and 11.91 Biphenyl. 0.881 Santowax R + 0.119 Biphenyl + 10.3 Cl2 _____ Solid + 10.3 RC1 Aroclor 230.3 154.2 70.9 586.0 36.5 Tlalda oar CWT Aroclor Chlorine Biphenyl Santowax R Hydrogen Chloride Theory 121.4 5.01 36.2 64.1 Standard 146.3 -- 42.3 54.5 MONS 049666 HONS 049667 STARDA1D MANUFACTURING PROCESS FOR AKOCLOR FLOW SHEETS HONS 049668 HONS 049669 HONS 049670 - yy'CHLORINATOA CIRCULATING PyVIP BATCH CHlGRINATQR OPERATION FLOW SHEET. HONS 049671 ANNISTON PLANT - MONSANTO CHEMICAL COMPANY - ANNISTON. ALA. .BATCH CHLORINATOR OPERATION -- FLOW SHEET DRAWN if EAE APmovto DATS a-7-64 CAU NONE OVFT. . AROCLOR TS-A-701 STEAM m ^SC:.CR ST,__-- - LC W SHEET TO AROCLOH STORAGE TANKS. TANK CARS, OR DRCY13. HONS 049672 EAE ANNUTON PLANT - MONSANTO CHEMICAL COMPANY - ANNISTON. ALA. R still. - FLOW 5METET AArftOVKO DATA Q-\0-4.4 CALK none: . ill 1111 II IM DBPT. AttQCLO* TS-A-704 *> 5 = rnO 0 ONOANTO CHEMICAL COMPANY MOANI6 SMCMICALS DIVISION OlOINtWMMO DSDARTMSNT IT. LOUIS. MISSOURI baoip Hcl off (5a6 HMi\ ChuorihatoPS BBTIHATB NO.-- PRBPANSD BYNn__________ PMM CbuiinaToij 5-8 54<1 0ff Gas CohPEhSER 'owls. VA-rt*. OvT IoyyBA V/ATEK In STtAIA U -- StiaM O-'*' 5 76 OtMlSTER 573 Liai-'ios Colluc+ior T Mi K, ASV. NO. DATS DIVISION sv or MONS 049673 MONSANTO CHEMICAL. COMPANY ODOANIt ONtMlOALt DIVISION NOINMNINO OKVAftTMKMV t. LOUIS. M'MOUAI SsmO HCL Off Gas ZIe.AH .111._________ nA.ctAmti?Tca_____________ lOCATIOAllH i.SXflWi At-A___ nrivm mo.. PWCPARtD Y_ J_ _ i:--! N. | e. * cl u 580 ^T<> h c l Absorber tv. NO. DATS NCVINOM ANDOVIO or DAT* Y HONS 049674 1 I I______________ _____________ _____________ _____________ w iWMie ewKu wwn . . V. o. xjutmmjuch MdWT RAW MATBWtM. __ yICIFICATIOW * ___n IIWH flMil r*ci) nut httitt JltS_______ CMCUAJBmiD OOrOAMAnOM General Tt tana da ealy aa Pmerty < Appearance Aaaay OaUatea Ferrou Salt* Salability: 10:10 of water 10:10 of Fonaal* JO alcebol H. Bmu Spadflcatlaa Black powder or Iraniaa 97.0%, Mia. 1,05%, Max. Tract, Max. Camplata ta allfktly tarMd, Max. Coenplete to illgklly tarbid, Max. MUOtTab. U, 1917 ITMIjm KP1I w 142.21 J.r.O. MoftoARljgE U-A 22-070 120-no S-070-1 112-B MONS 099 773 MONS 049774 Vapor. of A-sn-as A t 5.. P t u e s Si 1 iC (~5T SCAI-E) /A A^-T* HONS 049775 Monsanto . fMM (NAME LOCATION! St. Louis Organic Research m. November 3, 1970 vijcct i - AROCLORS MARKETING REQUEST 70-102 TO : W. S. Clark WCLAR J. W. Baker ccM. W. Farrar - Res. 1 A. W. M. Coaker - Res. 3 J. T. Bell - Anniston G. W. Miller - Anniston C. E. Vogler - Res. 2 W. R. Richard/Q. E. Thompson - WR We have completed the work you specified in your Marketing Request 70-102 for the new Aroclors. This information was needed for a customer (3M) and will also be included in a future product bulletin. . The distillation range (225-280' C. at 9 mm.) for Aroclor 5432 was carried out by the Anniston Laboratory. A memo describing their results is attached. The vapor pressures for Aroclor 6040, 6050, 6062, and 5432 were carried out by C. E. Vogler and the vapor pressure curves covering the temperature range of 150 C. up are attached. Extrapolation of the curves gives the following values for 100* C.: Aroclor 6040 Aroclor 6050 Aroclor 6062 Aroclor 5432 2.1 mm. 1.9 mm. 1.2 mm. 0.014 mm Please let me know if you have any questions. \M fo J. W. Baker att. PP MUNS 049776 Monsanto fMN inamk * location! J. T. Bell - Anniston. Alabama TO : J. W. Baker Queeny Plant c?' G. L. Arnett J. L, Brown - S. 0. Kemp C. E. Vogler - Queeny As you requested, samples of Aroclors 6040, 6050, 6062 and 5432 have been forwarded to C. E. Vogler. The distillation conditions for Aroclor 5432 are listed below and are taken from the report (#1, Job No. 446-515) by G. L. Arnett dated 5/26/70. ' Vacuum (mm) 9 First Drop: Pot Temp., *C Heod Temp., *C 260 225 Last Portion Retained: Pot Temp., #C Bead Temp., *C 320 280 May I suggest that for purposes of a Product Bulletin, distillation ranges may be more appropriate. '' '' Joe, please let me know if we can be of additional assistance. J. T. Bell Jv (< *V It.*, MQNS 049777 too 400 00 I090| . Vspuv pressure R&co>Jiy)^ ofARodoR s*/3x ' | -r~t 1 f /1 4- h- 7 1 4 t 4l / 7i t 7 l 1 1 t h 4 1 TI l t |Pl--__ L____ ,U..II .........I 1 -1 -1 - 1/--1 -t 100 too / 200 1 HONS 0`9781 lllniiiiimii1-----1 -I -t 1- t - I L I _1 1 .1 1 .1 L I I. I L 1 1 I 1 000 400 000 O" f I i i i 3SS mmmm TECHN L CAL BULLETIN THE AROCLOR* POLYCHLORINATED POLYPHENYLS A series of heat-resistant, chemically inert and , fire-retarding compounds ranging from mobile j oily liquids through viscous resins and solids that perform unique functions in over a hundred dif * ferent industrial and product applications. : TECHNICAL BULLETIN O-FF/1 4 HONS 049787 THE AROCLOR* POLYCHLORINATED POLYPHENYLS A series of heat-resistant, chemically inert and fire-retarding compounds ranging from mobile oily liquids through viscous resins and solids that perform unique functions in over a hundred dif ferent industrial and product applications. TECHNICAL BULLETIN O-FF/1 FLUIDS Tilt IrtarmetlanseMalna*In Hifi Misti* ll.ttav* bail kwMit, trie* iH ecswftia. M allieteiitfaeM*M**i m uwnUMtl l' M4* wtthaat Malta's*. tMtt tt* Camps** Matalmi t*r lla**M wtwfaC la tsmealM* Mia thetsiiwt eftMitattselfattaa*aMi il asMeiH|lHW||iTkra*mWaWmMafsitsa Mint ceWalaae heraf* shell as cenMfaH as i tetammeadsllsn ta we any wadset in e*n*M *tth asMltea a*la*4s caaatMf any mt<eii*l a* tie ata. Organic Olvldcn / 100 N. llnrfhcr|h BM. / It. lU, Mlttccrl Mill HONS 049788 2 m .u Table of Contents GENERAL PHYSICAL PROPERTIES CHART . 4 ELECTRICAL APPLICATION OF AROCLOR . Dielectrics for Askarel Type Capacitors and Transformers........................ Impregnating Compounds............................ 7 7 7 MECHANICAL APPLICATIONS OF AROCLOR 10 Expansion Medium......................................... It Liquid Sealant for Furnace Roofs................ It Vacuum Diffusion Pump Oil........................ 11 AROCLOR IN SPECIAL PRODUCT FORMULATIONS............................................. 12 Sealers lor Gaskets..................................... 12 Dedusting Agent......................................... 12 Insecticides................................................. 12 Precision Casting Waxes............................ 12 Ablative*..................................................... 13 Specialized Lubricants................................. 13 Industrial Cutting Oils................................ 14 Appendix Methods for Emulsifying................................ 15 Solubility Table................................................. 16 Vapor Pressure................................................. 17 Vaporization Rataa............................................. 18 Corrosion Resistance of Structural Materials. . 19 Viscosity Table................................................. 20 Density Table..................................................... 21 Dermatology & Toxicity..................................... 22 Safe Hendling................................................. 23 Shipping Information......................................... 23 Ask your Man from Monsanto for additions! Arodor literature: Askarel Inspection and Maintenance Guide Aroclor* Plasticizers Technical Bulletin Therminol FR Fluid Heat Systems Engineering Heat Transfer Data Aroclor, Thetminol, Staiox, Samomarae. Formvar, UuMron. ind Resinox are rtgistarad trademarks of Monsanto Company. MONS 049789 What are the Aroclor Polychlorinated Polyphenyls These compounds are a series of chlorinated bi phenyls and chlorinated polyphenyls. They range in form and appearance from mobile oily liquids to fine white crystals and hard transparent resins. Aroclor is non-oxidizing, permanently thermo plastic, of low volatility, and non-corrosive to metals. Aroclor is not hydrolyzed by water, al kalis, or acids. The viscous liquids and resins will not support combustion when heated alone, and they impart fire-resistance to other materials.- Crystalline Aroclor is relatively insoluble, but the liquid and resinous compounds are soluble in most of the common organic solvents, thinners and oils. All Aroclor chlorinated compounds are insoluble in water, glycerine or the glycols. Aroclor 5460 is insoluble in the lower molecular weight alcohols; 4465 is only partly soluble in the lower alcohols. Aroclor is used alone for a particular physical Job, such as insulating, and as a sealant or expansion media. Aroclor is also used as a component or ex tender in elastomers, adhesives, paints, lacquers, varnishes, pigments and waxes. The properties imparted by Aroclor (and their usefulness in par ticular applications) vary in regular gradient over the series. Selection of the right Aroclor for a par ticular use can generally be mode by comparison of the properties, by blending two or more, and by adjusting the percentage used in the particular mixture in which the Aroclor will be formulated. The following table describes the properties of twelve Aroclor chlorinated compounds, each of which is representative of a series. For almost every Aroclor shown, there is a dark-colored grade of approximately the same physical and chemical characteristics. These darker products are less pure, but are lower in price. MGNS 049790 General Physical Properties of the Arador Chlorinated Compounds Form........................................................ Aroctor 1221 Colorless mobile oil Color........................................................ Acidity -- Maximum (Mem. KOH per Cm.). . Average Coefficient of Expansion.. cc/a/'C Typical Density Specific Gravity . . .............. Pounds par gallon -- 25*C(77-F).............. Distillation Range -- ASTM D-20 (Mod.) Corr. *C.................................................. 50 Max. (APHA) 0.014 0.00071 (15*-40*C) 1.102-1.192 (25715.5*$ 9.85 275*-320 Evaporation Lots -- % -- ASTM 0-6 Mod. 163*C.............................................5 hrx. )00*C............................................ 6 hrs. Flash Point - Cleveland Open Cup..........."C *F Fire Point -- Cleveland Open Cup.............*C "F Pour Point-ASTM 0-97........................ *C *F Softening Point -- ASTM E-ZS..................C F Refractive Index -- D-line -- 20*C.................... Viscosity - Saybott Universal 210*f (98.9"C) Sec. (ASTM - 0-88) 130"F (54.4C) IOOT (37.8*C) SeONI UWatlH - *eait If MtM| tfNWWMMf" -- i.O to 1.5 141 150286 *-302* 176* 349* Crystals at t*C Crystals at 34 *f - - 1.617-1.618 30-31 35-37 38-41 Aroclor 1232 Practically colorless mobile oil 50 Max. (APHA) 0.014 0.00073 (25MOO*C) 1.270-1.280 (25715.5*0 10.55 290*-325" Aroclor 1242 Practically colorless mobile oil 50 Max. (APHA) 0.010 0.00068 (25-65*C) 1.381-1.392 (25715.5*0 11.50 325*-366* Aroclor 1248 Colorless to light yellowgreen, clear, mobile oil 50 Max. (APHA) 0.010 0.00070 (25*-65*C) 1.405-1.415 (65*/15.5*C) 12.04 340"-375* -- 1.0 to 1.5 152-154" 305*-310* 238* 460* -35.5* -32* - - 1.620-1.622 31-32 39-4) 44-51 3.0 to 3.6 0.0 to 0.4 176- 180" 348*356* None* -19* 2* 3.0 to 4.0 0.0 to 0.3 193- 196379M84* None -7* 19.4- - 1.627-1.629 34-35 49-56 82-92 - 1.630-1.631 36-37 73-80 185-240 HONS 049791 Aroclor 1254 Light yellow viscous oil SOMex. (APHA) 0.010 0.00066 (Z5--65-C) 1,496 1.506 (85715.5*C) 12.82 365*-3\ - *-->J 1.1 to 1.3 0.0 to 0.2 None None 10* 50* - - 1.639-1.641 44-48 260-340 1800-250 4 1 Aroclor 1260 Light yellow soft sticky railn " 50 max. (APHA) 0.014 * 0.00067 (20M00-C) 1.555*1.560 (90715.5`C) 13.50 ' 5*-420" 0.5 to 0.8 0.0 to 0.1 Norn Norn 31* 88* - _ 1.647-1.649 72*78 3200-4500 _ Aroclor 1262 Light yellow sticky clear resin 60 Max. (APHA) 0.014 0.00064 (25--65-C) 1.572-1.583 (90-/15.5-C) 1372 39S--425* 0.5 to 0.6 0.0 to 0.1 None None 35--3B' 99* - 1.6501-1.6517 86*100 600-850 oao*r or n*o Aroclor 1268 While to olf-white powder 1.5 Max. NPA (molten) 0.05 0.00067 (20*-100*C) 1.804-1.811 (25-/25-C) 15.09 435M50* 0.1 to 0.2 0.0 to 0.06 None None - - 150* to 170* (hold pt.) 302* to 338* (hold pt.) - - _ __ Aroclor 4465 Light-yellow, clear, brittle resin 2 Max. NPA (molten) 0.05 0.00061 (25*65C) 1.670 (25725"C) 13.91 230M20* at 4 mm. Hg. 0.2 to 0.3 0.0 to 0.02 None None - 60 to 66* 140" to 151* 1.664 1.667 90-150 <2**r *110*0 _ _ Aroclor 5442 Yellow transparent sticky resin 2 Max. NPA (molten) 0.05 0.00123 (25-99C) 1.470 {25-/25-0 12.24 Aroclor 5460 Clear, yellowto-ambei, brittle resin 2 Max. NPA (molten) 0.05 0.00179 (25- 124-C) 1.670 <25-/25*0 13.91 Black, opaque, brittle resin 1.4 0.00066 (25*-65*C) 1.734 (25-/25*0 14.44 215*-300 at 4 mm. Hg. 280* 335" at 5 mm. Hg. 0.2 0.01 247* 477* >350* >662* 46" 115* 0.03 1.5 to 1.7 1st 2OT-S fart.) None None - 46* to 52* 115* to 126* 98* to 105.5" 208* to 222* 300-400 _ 1.660 1.665 - -- -- MOMS 099792 0.2 to 0.3 None None - 66* to 72* 149- to 162* - - -- __ RESISTANCE TO DRYING Aroclor i non-drying, feven when exposed to air in the form of thin films, no noticeable oxidation or hardening takes place. However, when used as a component of paints, varnishes or lacquers, it docs not retard the rate of drying of the films. Quick drying varnishes and paints can be made using Aroclor in the formulation. FIRE-RESISTANCE Viscous, oil-like Aroclor and the Aroclor resins do not support combustion when heated alone, even at their boiling points -- temperatures in excess of 350C. Most of the Aroclor chlorinated com pounds flux readily with other resinous and pitch like materials to make mixtures that gain in fire retardance properties. Even when incorporated in nitro-cellulose films and rubber foams, Aroclor will retard the rate of burning. ADHESIVENESS AND THERMOPLASTICITY The Aroclor resins adhere strongly to smooth surfaces such as glass, metal, varnished or lac quered coatings. Aroclor is permanently thermoplastic. It appar ently undergoes no condensation or hardening upon repeated melting and cooling. Clear Aroclor resins can be supplied with softening points up to lOB'C. Opaque, crystalline Aroclor can be sup plied with initial melting points up to approxi mately 290'F. STABILITY Toward Alkalies -- Aroclor is remarkably re sistant to the action of either hydrolyzing agents or high temperature. It is not affected by boiling with sodium hydroxide solution. Toward Acids -- Experiments were made to de termine whether hydrogen chloride is evolved dur ing the treatment of Aroclor with sulfuric acid. Aroclor 1254 (selected as typical) was stirred with an equal volume of ten per cent sulfuric acid for a period of 150 hours. Any gases escaping from the reaction flask had to pass through a trap filled with silver nitrate solution, which would give a precipitate of silver chloride if any HCI came in contact with it. After 150 hours of treatment, neither the trap solution nor the acid layer in the treating flask showed any hydrogen chloride present. Even prolonged treatment (255 hours) with con centrated sulfuric acid indicated negligible effect. Toward Heat -- Aroclor is a useful heat transfer media because of its stability to heat. Aroclor 1254 and particularly the less viscous Aroclor 1248 are recommended for this purpose because they may be heated at temperatures up to 315C (600F) in a closed system for long periods without appre ciable decomposition and they are fire-resistant. Toward Oxidation -- When Aroclor is subjected to a bomb test at 140*C with 250 pounds oxygen per square inch, there is no evidence of oxidation as judged by development of acidity or formation of sludge. ELECTRICAL RESISTIVITY Aroclor has extremely interesting electrical charac teristics: high resistivity and dielectric strength and low power factor. The dielectric constant ranges from 3.4 to 5.0 at 100C and 1000 cycles, depending upon the particular Aroclor. SOLUBILITY All Aroclor chlorinated compounds are insoluble in water. They are soluble, however, in most of the common solvents, plasticizers, and resins. The Aroclor oils and resins are readily soluble in most of the common organic solvents and drying oils. Hard crystalline Aroclor is in genera) less soluble than the liquid or softer Aroclor resins. Aroclor is heavier than water, a valuable property for many applications. HUNS 049793 6 Electrical Applications of Aroclor .L Aroclor is one ofHhe purest commercial chemical compounds, virtually free of even traces of con* ducting impurities. For tikis reason, dielectric properties of Aroclor closely approximate the theoretical maximum for these particular organic compounds. With its stability, heat-resistance and Are resistance -- Aroclor can be used for a variety of heavy-duty dielectric applications. DIELECTRICS FOR ASKAREL TYPE CAPACITORS AND TRANSFORMERS Aroclor is used per se in capacitors and is formu lated for the liquid coolant-insulation fluids in transformers. Such dielectrics must be highly pure with dependably minimal traces of electrolytes. They must be chemically stable and non-corrosive to a wide variety of structural materials. Most im portant, the dielectric fluid must be fire-resistant. Aroclor is the only liquid in low cost commercial supply thut meets these exacting requirements. Aroclor liquids 1243, 1248, 1264, and 1260 are used directly, or are carefully formulated with chlorinated benzene and other additives to make askarel fluid for particular needs. Typical formu lated askarel fluids are shown on the following pages. Aroclor liquids 1242 and 1254, themselves or in special formulations, are used as the dielectric in fixed paper capacitors, for the power factor correc tion in utility transmission lines; for home ap pliances such as air conditioners, furnaces, washers and driers; for electric motors; and for ballast in fluorescent fixtures. There are also a number of applications in DC systems, in con densers, and the new energy storage capacitors. The Aroclor fluids can be used in a wide variety of applications requiring a specialized dielectric. Monsanto works closely with electrical equipment makers to develop the proper dielectric with the exact physical properties required by the engineer ing of the equipment. IMPREGNATING COMPOUNDS Because of its nonflammability, high resistivity, dielectric strength and low power factor, liquid and resinous Aroclor is extremely useful as an impregnating compound. An important applica tion of Aroclor in the electrical field is the use of Aroclor 1260, 4465, and 5460 in wire or cable coatings and as impregnants for cotton and asbes tos braided insulation. Because they possess high purity and excellent electrical resistance, Aroclor 1254, 5460 and 1268 make superior dielectric sealants to close the pores of carbon resistors, and to seal electrical bushings and terminals. To attain the lowest possible loss factor and gain resistivity, Aroclor is often treated with about 0.20% by weight of Attaupulgus clay or Fullers earth. To activate the earth it should be heated to 460*-600wF. ELECTRICAL PROPERTIES DMSMrW Cewtant at 1,000 Cptea (1) Areeter 100*6 Velum! Ptaatstivlly (2) Ohm-em et 100*6, 500 Vilts D.C. Dlefeetrle Itreiiflh (8) Fewer Feeler (4) 100*6,1,000 Cyelee 1232 5.7 4.6 1242 5.8 4.9 Above 500x10* Greater than 35KV <0.155 1248 5.6 4.6 Above 500x10* Greater than 35KV K 1254 5.0 4.3 Above 500x10* Greater than 35KV <0.155 1260 4.3 3.7 Above 500xlP Greater than 35KV <0.154 1268 2.5 -- 5442 3.0 4.9 Above 500x10* 5454 2.7 4.2 5460 2.5 3.7 MONS 049794 4465 2.7 3.3 (I) ATM D-IM-NI It) ASTM 0-W< (I) AITM (Mtt-U (!) ASTM O-IIMrr 7 TYPICAL TRANSFORMER ASKAREL . k. (MIXTURE OF AROCLOR AND CHLOROBENZENES) Prenrty Vise. r. 37.*C. (ASTM DBS) Spec. Gravity 15.5/15.5*0., (ASTM D287) Color, APHA Condition Acidity. m(. KOH/g. Pour Pt,, "C,, (ASTM 097) litorianlc Chlorides, ppm Ralractlvo Index m 25*C. Distillation Range (ASTM D20) Corrected for stem and barometric pressure First drop 55% 55% m Corrosion Water Contant, ppm. Resistivity, X00*C., 500v,, 0.1' gap Dielectric Strength, 25'C. Dielectric Constant 100"C,, 1000 cycles* Tin Tatrapbanyl* Burn Point (ASTM D92)* Fixed Chlorine* Arc Formed Gases* (Oxygen Free Liquid & 25"C.) Electrical Stability* 'OHitMMt by Typiaal 41*45 Sec. Saybolt Univ. 1.563-1.571 150 max. Clear 0.01 max. -44*C., or lower 0.10 max. 1.6075-1.6085 2I0C., min. 240*256*C. 290*330*0. 385*400C. 395*415*0. Alter heating with aluminum for 6 hrs. @ 200*220*0., the aluminum must not be corroded either on visual or weight inspection. The askarel fluid meets the following specifications: Coior, APHA 200 max. Acidity, mg. KOH/g. 0.01 max. Inorg. Chlorides, ppm 5 max. Condition Clear 30 max. 100 x 10* ohm-cm., min. 35 KV.t min. 3.S-4.2 0.125% 0.01% by weight None up to Boiling Point 60.5 0.5 . Total combustible gases including carbon monoxide, hydro gen and volatile hydrocarbons. After heating for 96 hours @ 100*0 in s closed container, the resistivity should not decrease more than 10%. MONS 049795 TYPICAL CAPACITOR AROCLOR Prenerty t Vise. ( 37.8*C. (ASTM 088) Specific Gravity 25/15.5*C (ASTM D287) Color, APHA Condition Acidity, mg. KOH/g. Pour Pt., *C. (ASTM D97) Inorganic Chlorides, ppm Refractive Index ( 25 C. Distillation Range (ASTM 020) Corrected for stem and barometric pressure Corrosion Water Content, ppm Resistivity 100C. 500 volts DC @ 0.1' gap Dielectric Constant IOO"C. @ 1000 cycles (ASTM D92<) Flash Point Cteve. Open Cup* Fire Point C.* Sutfetes (ASTM-D117-31)* Fixed chlorine content (Carius)* Specific Hast 25*C* Evaporation 100*C for 6 hrs.* Dielectric Strength (KV) (ASTM D877)* Typleal - 82*92 seconds Saybolt Ufliv. 1.381*1.392 50 max. Clear 0.01 max. -14 or lower 0.10 max. 1.6240*1.6260 10% 325C. min. 90% 360C. max. After heating with aluminum for six hours at 210*C 10*C the aluminum must not be corroded either on visual or weight inspection and the Aroclor 1242 should meet the following specs.: Color, APHA 60 max. Acidity, mg. KOH/g. 0.01 max. Inorg. Chlorides, ppm 0.10 max. Condition Clear 35 max. 500 x 10* ohm-cm., min. 4.7-4.9 170C., min. Nona to boiling point Nona 41.5-42.5% 0.29 M% max. 35 Min. 'MMM ty Mm DIELECTRIC CONSTANT VS. TEMPERATURE Aroclor* 1242 & Aroclor* 12S4 HONS 049796 S Mechanical Applications of Aroclor Because Aroclor chlorinated compounds have ex cellent shear resistance, heal stability, and are chemically stable . . . they can serve in dozens of mcchanicR) applications for transferring mechanicu) power, heat and variable pressures. Aroclor does not attack metals even at high temperature; it resists oxidation, chemical and mechanical breakdown under a wide variety of environmental conditions. Aroclor liquids used as lubricants im part a high degree of extreme pressure lubricity. HEAT CAPACITY OF AROCLOR LIQUIDS at Various Temperatures THERMAL CONDUCTIVITY OF AROCLOR 1248 Timpsrsturs C. F. 30 90 60 140 too 212 TU./Hr./Sq. Ft/ 0.0680 0.0687 0.0697 Cetorlw, frem/Stt./ q.Cm./C./Cm. 281 x 10-' 284 x 10-' 288 x JO-' 10 MONS 049797 EXPANSION MEDIUM Because of their stability at high temperatures and ability to withstand frequent temperature cycles without gum formation, Aroclor liquid is used as the actuating medium in bellows controls, thermo stats, industrial temperature control regulators and other kinds of automation equipment. The average coefficient of expansion of Aroclor 1248 per degree F withi n the various temperature ranges indicated in the table below was determined by using the simple formula Vt = Vt* (1 + a (t -- t).J The coefficient a, has been calculated at 100F increments os follows; Tamp. Range F 0 to 100 100 to 200 200 to 300 300 to 400 400 to 500 500 to 600 Avars* Csaffietont at Eapantian ae/ao/F 0.00037 0.00039 0.00040 0.0004$ 0.00048 0.00051 The specific volume of Aroclor 1248 at different temperatures is as follows: Temp. *F 0 100 200 300 400 500 600 tpaaifls Valumt ml/gm 0.674 0.699 0.726 0.755 0.790 0.828 0.870 LIQUID SEALANT FOR FURNACE ROOFS Because of their low vapor pressures and fire* resistance, Aroclor 1248 and 1254 make excellent liquid sealants. These non-evaporating fluids have good flow at slightly elevated temperatures and are chemically stable at elevated temperatures. Consequently, Aroclor liquid makes excellent fluid sealants for any application where the use of oil would create a fire hazard. In the trough of an nealing furnaces, for example, Aroclor makes de pendable fire-safe roof seals. VACUUM DIFFUSION PUMP OIL Fluid Aroclor 1248 and 1254 are highly stable to air; they make good oils for vacuum pumps at a much tower cost than high priced silicone type oils. Aroclor operates efficiently in vacuum diffusion pumps used to pull high vacuum for metalizing plastics, dehydrating foods, medicinals, and for drying capacitor cones. HONS 049798 Aroclor in Special Product Formulations With their wide range of physical properties, their inertness, lubricity, and vapor-Buppressing char acteristics -- Aroclor chlorinated compounds can be valuable ingredients in an extraordinary variety of formulated products. They are compatible with a variety of solvents, oils and resins. Virtually nonvolatile and permanently thermoplastic, they will not react with other chemicals in the formula tion. In addition, their low cost makes their use for special purposes eminently practical and eco nomical. SEALERS FOR GASKETS Aroclor -- particularly when hot -- swells rubbers like Hycar\ Koroseal*, PerBuna N, and Neo prene. Wherever seals and gaskets of natural or synthetic rubber tend to shrink under heat and use, Aroclor 1232, 1242, or 1254 can be used as a swelling agent to tighten the shrunken seal. An example is in automotive transmission oil: a small amount of Aroclor in the oil swells the seal in place, saving the cost of tearing down the equip ment to replace the seal or gasket. Aroclor can be used in gasket sealing compounds to swell the rubber after the gasket or seal is in place. DEDUSTING AGENT Aroclor 1264 is a low cost dedusting agent which can hold down the dusting of a variety of chemical products. Because Aroclor 1254 resists both com bustion and oxidation, it can be used to control dusting of highly reactive compounds. As a typical example,(1) a few tenths of one percent will con trol the dusting of calcium hypochlorite. WpiM mt MNMMM IIMMtlM 1.1. QMttKft C*. (I) Owwtf tr v. t, PilMrt It*. Lni.fi I, MMrt )HK, if. ML M ** ts FtMitfl INSECTICIDES Aroclor 5460 and 1254 act as vapor suppressants. United States Department of Agriculture scienttists reported that the inclusion of from 5 to 25 parts per hundred by weight of Aroclor increased the effective kill-life of a lindane spray up to ten times. A painted or metallic surface sprayed with certain chlorinated insecticides fortified with Aroclor will remain toxic to Dies, ants, roaches and silverfish up to 2 to 8 months. The Aroclor resins suppress the rapid evaporation of the volatile insecticides without adding odor or other objec tionable residue. Formulation into insecticides is quite simple; the Aroclor is dissolved in a suitable solvent compatible with the insecticide formula tion, and mixed in. The most pronounced effect for increasing the kill-life of the insecticide is ob tained with lindane, chlordane and BHC. Aroclor is recommended for chlorinated insecticide formu lations to be used for non-crop spraying. Their low cost makes this use a most practical way to lower the ultimate cost of insect control. PRECISION CASTING WAXES Aroclor is compatible with various natural waxes, such as caroauba and others, including those used to formulate casting wax. Aroclor helps impart to the finished casting wax a number of desirable properties: hardness without brittleness; resist ance to shrinking; sharp definition; sharp melting point; and fire-resistance. Waxes formulated with Aroclor are non-tacky and highly stable. Waxes containing Aroclor are widely used in making dental castings, in the precision casting of aircraft parts, and for casting costume jewelry. Aroclor 1254, 4465 and 5460 are most frequently used . . . proportions dependent upon the properties re- MGNS 049799 quired in the finished wax. Much of the highest quality precision casting wax used in the lost wax process is formulated with Aroclor. AROCLOR IN ABRASIVES Aroclor 1254,1268 and 5460 are used in the manu facture of specialized abrasives. Because of their excellent bonding characteristics, high thermal stability and resistance to oxidation and corrosion -- Aroclor is used as the carrier for abrasive ma terials. A major use is as part of the bonding agent in specialised grinding wheels. AROCLOR IN SPECIALIZED LUBRICANTS For specialized lubricants requiring good extreme pressure (EP) characteristics, the Aroclor liquids make excellent additives. They impart high tem perature stability, excellent lubricating qualities, and weather and corrosion resistance. As an ex ample, Aroclor is used to formulate grease and pipe thread compounds for use in oxygen systems. Greases formulated with Aroclor have a high chemical resistance and are suitable for use in contact with corrosive chemicals. Gear oil lubri cants containing Aroclor have good resistance to sheer degradation and high temperature stability. Added in small amounts to railroad car journal box oils, Aroclor imparts better extreme pressure lubricity and reduces the incidence of hot boxes. The heat-resisting, nonflammable characteristics of the Aroclor chlorinated compounds make them attractive in themselves as lubricants under condi tions of high temperature. As an example: in gov ernor systems of central power stations, Aroclor 1248 is well suited to this lubricating application. Straight Aroclor 1254 gives excellent results on a roller bearing test operating at 255-2$0F with much less carbonization or decomposition than the usual spindle oil under the same conditions. As an extreme pressure (EP) lubricant base added to a petroleum hydrocarbon oil in amounts up to approximately 15% by weight, Aroclor 1248 and 1254 materially increase the load-carrying proper ties without reducing the viscosity of the resulting composition. These two compounds represent one of the more satisfactory carriers for the element chlorine as an extreme pressure base, possessing the following advantages: 1. STABILITY. Even at higher temperatures, there will be neither separation of components nor appreciable change in physical or chemical properties during long periods of operation. 2. NON-VOLATILE. Many other types of chlo rine bearing compounds are so volatile as to render them unfit for long periods of service. Aroclor is non-volatile at normal temperatures. 3. NON-OXIDIZING. Aroclor does not oxidize nor thicken up to an objectionable degree. 4. NON-CORROSIVE. Aroclor does not attack metal surfaces. 5. NON-ABRASIVE. Aroclor exerts no abrasion on the machined surfaces. 6. NON-HYDROLYSIS. Aroclor does not hy drolyze in the presence of water, thus avoiding the generation of hydrochloric acid. 7. COMPATIBILITY. Aroclor is completely miscible with mineral oiiB. 8. COLOR. Aroclor does not darken or change the color of lubricating oil. MOMS 049800 13 Where lubrication is subjected to water displace ment exposure, for example in the lubrication of bridge rollers, a heavier-than-water lubricant can be prepared from mixtures of Aroclor and oil. The following are typical examples: Mil N. 1 2 'tt-.uwttvwi % by walpHI Oil* Araelar 1241 50 50 25 75 Viscosity 210F-160 Sayboil Secs. Color ASTM 7-8 Flash Point 545'F. Pour Point 15*F. PaurPt. 0F +5F Gravity at 15.8C. 1.1263 1.2703 Ayprtx. Ptunfe/ftal. 94 10.6 AROCLOR IN INDUSTRIAL CUTTING OILS Aroclor 1254 is used to formulate the finest quality straight and soluble or emulsifiable-type cutting oils. The Aroclor functions as an excellent extremepressure lubricant and is far superior to aliphatic chlorinated hydrocarbons because of its higher order of thermal stability. The heal resistance is most important in cutting oils for machining high grade steel. With Aroclor cutting oils there is a lower degree of hydrolysis which minimizes the staining of the metal. HONS 049801 14 .L Appendix Methods for Emulsifying and Making Stock Solutions of Arodor There are several simple methods for making Aroclor emulsions; the one used may be selected to suit the kind of Aroclor and type of formulation in which it will be used. Emulsifying Viscoue Aroclor (Portion 1) 16 lbs. of Aroclor 1 lb. of stearic acid (Portion 2) 8 lbs. of water 4 oz. Triethanolamine Heat the Aroclor to a workable viscosity (180F plus) and stir in the stearic acid thoroughly. Heat the water to almost boiling (207F) and stir in the triethanolamine thoroughly. Pour the Aroclor stearic acid portion into the water portion, agitat ing vigorously. Then process the combined por tions with a highspeed emulsifying stirrer ... or process through a colloid mill. Emulsifiablo Concentrated Stock Solutions of Aroclor 79 parts of Aroclor 16.70 parts of toluene 3.55 parts of isopropyl alcohol 1.00 parts of Sterox CD non-ionic emulsifier 0.75 parts of Santomerse1' anionic wetting agent The above formulation is readily emulsifiable with water. If a more resinous Aroclor is used, increase the amount of toluene (or xylene) as needed to dissolve the Aroclor resin. HONS 049802 16 SOLUBILITY OF AROCLOR CHLORINATED COMPOUNDS IN 100 MILLILITERS * OF VARIOUS SOLVENTS Aroclor Type ol Solvent Acid Acotlc Acid Ololc Acid. Bentoie Acid Aldehyde 40% Formaldehyde. Furfural vs vs Amina Aniline............ . Pyridine................. 132.5 **C 440 rc 1U'C 425 too*e Chlero - derivative* Amyl chloride* - mixed Carbon Tetrachloride Chloroform................ Dtehlorethylene............... Elhylene bichloride .. Monochlorobentene ....... Orthodlehloroboniene . Tetraehlorethane............ Trlchlorethan*.. . . Tilchtorethylene................ Orylni Oil Tung Oil . Unaaod Oil..................... Eater Amyl Acetate..................... Butyl Acetate.................... Cettoeolve Acetate............ Cottonseed Oil.................. Dlbutyt Phthefate.. Diethyl Phthalete. . Ethyl Acetate................ Ethyl Lactate................... Ethylene Qlybol Dlecetete Malhyl Acetate................. Trlcretyi Phoephete.......... Ether: Ethyl Ethar.............. Ether Alcohol CerMtof*............................ Calloeolve........................ Dlolhylene Qiyeoi . . p-p' Dlhydroxy Ethyl Ether 224 H*C 307 173te*C 259 WC 8 J#*e Hydrocarbon Santana................ Dateline.............. Kerosene............... Mineral Spirit* Paraffin . . Pina OH.................... Toluene........ ........... Turpentine .. Xylene...................... VS vs VS VS 2.0 tn*c s VS VS vs s s vs vs 2.0H`C s vs vs vs vs vs vs vs vs Hydroxy--derlvet*ves Amyl Alcohol. . n-Butyl Alcohol .. Ethyl Alcohol (3 A) Olycerlne................ Methyl Alcohol Phenol--90% s $ 23.3 tre 28 *c I 22.2 'C Ketone Acetone .......... Mleeellaneoua Carbon Oleulfide. NMiobentene . Water.................. 142 178 a |tMi r AmM mt II l>M CktSlM CMt* C*. HONS 049803 16 I I HONS 049004 L VAPORIZATION RATES lemple wt. Lost Oms. Aroclor 1221 Aroclor 1232 Aroclor 1242 Aroclor 1248 chlorinated paraffin dioclyl phthalete Dutrex* 25 Aroclor 1254 Dutrex 20 Aroclor 1262 Aroclor 1260 Aroclor 4465 Aroclor 1220 Aroclor 5442 Aroclor 5460 Tricresyl phosphate 0.5125 0.2572 0.0995 0.0448 0.0745 0.0686 0.0256 0.0156 0.0047 0.0039 0.0026 0.0064 0.0045 0.0039 0.0032 0.0010 *0|IIM Wm SMIOil C*. Hauri Expasura 24 24 24 24 48 48 24 24 24 24 24 72 72 72 72 24 Surfaoa Area Cm.1 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 Vapariiatlan Rata 0mt./am.'hr./1OO*Q 0.00174 0.000874 0.000338 0.000152 0.000126 0.000117 0.000087 0.000053 0.000016 0.000013 0.000009 0.000007 0.000005 0.000004 0.000004 0.000003 APPROXIMATE VAPOR PRESSURES CALCULATED AT 100" F (37.8" C) Aroclor* 1232 Aroclor 1212 Aroclor 1248 Aroclor 1254 0.005 mm. Hg. 0.001 mm. He. 0.00037 mm. H|. 0.00006 mm. Hg. HONS 049005 CORROSION RESISTANCE OF STRUCTURAL MATERIALS MaUli 12 41 28 "C 126C Afttltf Number 12 54 26C 125C Aluminum......................................................................... R R R R Copper.............................................. R 0R0 Maintsium..................... ................................................ RR R R R Nickel...................................................................... RR R R RR Silver................................................................................. R R R R Tin................................................................................... R R R R Zinc.............................................................................. R R R R Mild Steel......................................................................... RR R RR RR Phosphor Brorue............................................................... R 0 R R Red Brass...................................................................... D D R 0 Stainless Steel (Type 316)................................................ RR RR RR RR Yollow Brass...................................................................... R Re R De Plastics Alkyd Resin No. 46594-12............................................... Alkyd Resin No. 46594-13A............................................... Cellulose Acetate (Flbastos).............................................. Durite(,) Phenol Furfural Resin......................................... Fotmvar* Mighty Plastieiied polyvinyl formal resins.. Formvar Low Plasticized polyvinyl formal resins....... Glyptei 1276...................................................................... Glyptal 7136...................................................................... Maleic Resin No. 465WI3B............................................ Maleic Resin No. 46594-13C.............................................. Methyl Methectylete......................................................... Luatron B Polystyrene................................................... Resinox* Mineral Filled Melamine Resin....................... Resinox Wood Flour Filled Melemine Resin...................... Resinox Mlperal Filled Phenol Formaldehyde................... Resinox Wood Flour Filled Phenol Formaldehyde............. Resinox Rat Filled Phenol Formaldehyde......................... Urea Formaldehyde Resin (Plaskon Co.)....................... P D D *0 De PS R *0 P P *D P 0 *0 0 0 D D P P P P T T P T P P P T P P 0 P D P *P P *0 P 0P R P Pe T PS T 0P *R T P P *R P 0 P PT *R R *R D 0 0 *0 R D *D 0 *P 4465 126 e RR D RR RR R R R R R R RR Re P P P D T T P T P P P T P R R D *D P tm itre RR D RR R R R RR RR R Ot RR Re P P P P T T P T P P P T *D P P P P P Ml (ic*niRi fniMintt last am l.l i to-'m/ww NMiitw m Ml* wr/yr. * OwWmlHMM- * IMIillWM*M Ut M~M4 H v t- tawfMgnWwwtMl* liHO.WM/i. 0 DmMM mwiUMIm Mnw II a IC-* cm/#y ar* IN a If* cm/y w Mm* .0M4 M .0I4 In/yr. nr mtm> mXKiMIlMmcta* MW 1 aWMM IittMMilMaMiMM*I*N*i* tmHn * t.oia Wrrg.lMW fllMriMMaWt*M<lMlMtm*HMt*MMWHmiln M M*tWtM IrrBfcMag liMattyHwfAlfW amtawMAssn Mllawg \* tana *>M> iMMlM iMM Mft ed tael >* iipasM fa* T alM* wttl Ml MtM MnMiMtr*. Ill PenHa *i t agiat*M Ih*w*i> 0 Inna CMraAMI <4, HONS 049006 19 VISCOSITY RANGES OF SOME OF THE AROCLOR* CHLORINATED COMPOUNDS MONS 049807 20 .U T t d e n s it y (Gm s ./c c) DENSITIES OF AROCLOR CHLORINATED COMPOUNDS AT VARIOUS TEMPERATURES MONS 049808 Dermatology and Toxicology At ordinary temperatures the Aroclor poly chlorinated polyphenyls have not presented in dustrial toxicological problems. The hazard of potential toxic exposure varies with their vola tility: the lower-chlorinated ones, being more volatile, present more of a potential problem from the standpoint of both inhalation and skin con tact. When Aroclor is used at elevated tempera tures, engineering controls must be applied, either by the use of closed systems or by effective localexhaust ventilation together with general work room exhaust. Inhalation tests on animals indicate that the maxi mum safe concentration of vapor is in the range of 0.5 to 1.0 milligram of the lower-chlorinated Aro clor compounds per cubic meter of air. The thresh old limits (maximum allowable concentration for an 8-hour working day) set by the American Con ference of Government Hygienists are 1.0 milli gram of the lower-chlorinated Aroclor compounds per cubic meter of air and 0.5 milligram of the more-highly-chlorinated compounds, such as Aro clor 1254, per cubic meter of air. Schwartz patch tests on 200 volunteers showed that neither Aroclor 1254 alone when applied to > gauze nor a polyvinyl chloride film containing 11.5-weight-per cent Aroclor 1254 was a primary irritant or a sensitizer. Canvas coated with an oilmodified alkyd resin (17-weight-per cent of the paint-film solids and 7-weight-per cent of the painted fabric was Aroclor 5460) did not produce primary skin irritancy or sensitization according to the same Schwartz technique. Continuous or re peated skin contact with Aroclor must be avoided because of the possible occurence of a condition called chlorance. Although reports of this condi tion caused by Aroclor are rare, it can be produced by excessive skin contact. HONS 049609 I Safe Handling Vapors of the Arocior liquids at room temperature should not be breathed in a confined space. Vapors evolved at elevated temperatures should not be allowed to bo dispersed into the general workroom. Instead, engineering control must be applied to reduce vapor concentrations below the allowable concentrations mentioned above. Continuous or repeated skin contact with Arocior must be avoided by the use of gloves and pro tective garments. If any Arocior is spilled on the skin, the skin should be washed in the usual man ner with a soap solution. A burn caused by contact with a hot Arocior should be treated like any ordinary burn. Arocior adhering to the burned area need not be removed immediately, unless treatment of the burn de mands it, in which case either soap and water or repeated washings with a vegetable oil are recom mended. Shipping Information Freight ClissIflMtien AROCIOR 1221,1243,1242. 1248.1254, 1260, 1262 RN ClaisHleatfen AR0CL0R 1268, 2565,4465, 5442, 5460 Track Clattlfleatlen AROCLOR 1268, 2565 AROCLOR 4465, 5442, 5460 Shlpplny fUyulititni Standard Centainers AROCLOR 1221 AROCLOR 1232 AROCLOR 1242, 1248, 1254, 1260,1262 AROCLOR 1268 AROCLOR 2565,4465 AROCLOR 5442 AROCLOR 5460 (flaked) Synthetic Resin, liquid, NOIBN Synthetic Resin, Other Then Liquid. NOIBN Synthetic Resin, Powder, NO) Synthetic Resin, Lumps or Solid Mess, NOI None Tank car, 520-lb. steel drum, 50-lb. can Tank car, 550-lb. steel drum, 50-lb. can Tank car, 600-lb. steel drum, 50-lb. cen 200-lb. fiber drum, 50-lb. cen 500-lb. steel drum, 50-lb. can 450-lb. steel drum, 50-lb. cen 100-lb. b| MONS 049810 23 r\ DISTRICT SALES OFFICES Additional District Offices are maintained by: ALL DIVISIONS ATLANTA. GEORGIA 30326 Lenox Towers West. 3390 Peachtree Pd. N.E. Tel. (404) 231-4320 BOSTON. MASSACHUSETTS 02149 Everett Station Tel. (617) Dunkirk 7-5010 CHICAGO. ILLINOIS 3159 Des Plaines Ave. Des Plaines. Illinois 60018 Tel. (312) 296-6698 CINCINNATI. OHIO 45206 1501 Madison Road Tel. (513) 751-6707 Agricultural Division FL DORAOO. ARKANSAS 71731 Smackovor Highway P 0. Box 231 Tel (501) Union 3 3151 LUUNG. LOUISIANA 70070 P. O Box 1 7d Tel. (504) 784 2911 Building Products Department ST. LOUIS MISSOURI 03100 BOO N Lindbergh Blvd Tol. (314) Wydown 3-1000 LOS ANGELES CALIFORNIA 90066 814 San Fernando Road Tel. (213) CA. 2-9111 CLEVELAND. OHIO 44122 3645 Werrensvi/le Center Pd. Tel. (216) 991-5400 DETROIT. MICHIGAN 48235 500 Northland Towers Tel. (313) 357-0910 HOUSTON. TEXAS 77002 1300 Main Street Tel. (713) Capitol 3-4011 LOS ANGELES. CALIFORNIA 90022 6670 E. Flotilla St. Tel. (213) Raymond 3 2492 MINNEAPOLIS. MINNESOTA 55402 912 Northster Center 110 S. Seventh St. Tel. (612) Federal 9-4651 Chemstrand Company Division AKRON. OHIO 44313 3030 West Market Si Tel. (216) Tomgle 6-7941 CHARLOTTE, NORTH CAROLINA 28202 Wachovea Bank Bu'ldmg 129 West Trade Si. Tel. (704) 378 9871 NEW YORK. NEW YORK 10001 350 Filth Ave. T*l. (212) 556-5100 ENGLEWOOD CLIFFS. N. J. 661 Palisades Ave. Englewood CMIs. Now Jersey 07631 Tel (701) S6R7151 NEW YORK. NEW YORK 10017 277 Perk Avenue Tel. (212) 922-4111 PITTSBURGH. PENNSYLVANIA 15222 No. 4 Getaway Center Bldg. Room 1406 Tel. (412) 261-2156 ST. LOUIS. MISSOURI 63166 900 N. Lindbergh Btvd. Tel (314) Wydown 3-1000 SAN FRANC/CSO BAY AREA 2710 Leleyette. Sente Clara. Calif. 95052 Tel. (408) 243-0414 SEATTLE. WASHINGTON 98104 911 Western Avenue Tel. (206) Mein 2-4203 Hydrocarbons & Polymers Division Lion Oil EL DORADO. ARKANSAS 71730 Lion Or) Building Tel. (501) Union 3-3111 JACKSON MISSISSIPPI 39209 P. O. Box 10937 Westland Station Tel (601) Fleetwood 2-30*8 LITTLE ROCK ARKANSAS 71203 1515 West Soventh Si. Tel. (501) Franklin 8-2437 MEMPHIS. TENNESSEE 38101 1023 Riverside Drive P 0. Box 252 Tel. (901) Whitehall 8-4451 SPRINGFIELD. MASSACHUSETTS 01101 J Organic Chemicals Division 730 Worcester Ave. (Rubber Industry) Tel. (413) 788-6911 * i WILMINGTON. DELAWARE 19803 2005 Concord Pike. Fairfax j Tel. (302) Olympia 8-6531 l 970 drown Street J P O Box 5307 Tel. (216) Hemlock 4-1921 049811 MONSANTO. 800 N. LINDBERGH BLVD.. ST. LOUIS. MISSOURI 63ISS 24 >-2UO-U4Oe0 UtHO l FUNCTIONAL FLUIDS HONS 0<*981^ MONSANTO. BOO N. LINDBERGH BLVO.. ST. LOUIS, MISSOURI (3166 ------ ... r m HO 3060 --!------~4!1 - ...c/. _.x c/?_ 2,HZ ! + 70 H,!Z Ms . cf> wi- -...... "2.900 ZOO I&/S 2^ 0 ZHO 5,5 i 7^S &> 22 3. 2 ) HOO II, Z / 2,15 ,1 HOS 7.V- MONS 049813 X. n.o'0 2>L Z. --- 5SA.7 7-- O. 1 6, ^ 3. /^> (J a. a 73.6.*^ o. ((? (* O.OlZ. o./7& Q .<JL>Uro(i33/>. ^|0<> '"kg) o, >,07,73 o",'/7 z. &*.S 7 O. 12.7 0,0*0 9 O.l 6 8 -7S& 6 0, /(?? ! p,<? *5WS 0, ! H 6? (>.% s 0.0.9O& *'7 0,0 6>t>[0 > / St 9 S7-Z `Z o.o7 z& c 0,0&lb (MS Hi H1,0 K&9&4 V> 0,o5H^> '7 b,m^> *>L, z. O.0363 3 0,100 o ./^S'b Z/5.0 / 0 .Qlbt- 3 o.l Z-2> 0,/V/Z. IZ,9 90 0, 0.00,1111 32. H MONS 049814 4^e/ *oh %Ht,0 c M. Cl J8.0 X /2. 01 4,7 x 1, 00& A. 2> X 3S.46 X. * 'B. Z/4 4.7 3^0 5 so r? M'l a H Cl C /4 Cl c K c( <y + x/cu 2*1,0 X .*2,0/ S X j.oob 10 * * 2-&>8> 7a l 'i `S */. 6 x sy,s# "rfzrr^* 24 X.i'Z.,0{ 4 X 1,00% 1 z X 2>S .^6 2-4 y /Zc(5i 4/ /Y 2-& S V4 7 SA / 72-0 ^ Zg>S v. H 65.0# Mf 05+ oo% a <hf -==r._ 0 Z-4 y /Z.o( w 4*5 v /,cy>$ Cl ./=>* 2>5.46 HONS 049615 "Z Z88 4.5 7- ` -N t- "6 *0 + / 7 I t /ftp 200 Z-YD 0 6 0 i0l # IZ.ftS ll .Si 10,50 $, 15 8. OZ7.0Z. (p. 5. ofe tt/'Z5.4 z- b.$0 lM 7 06 6,21 S .45 4, ^7 3.9Z5,2-0 6.6& S.99 S.Z>4 4, 7S 4-. 1 2> 5,6S 5. |S -Z..6S 2. IS /.725 H>12~ 3,Z7 2.2-1 2-/2-0 ) sso 1 1 OO "7 60 5Z.S 550 2-24 )5 1 70 4-0 080 "7/0 SO0 2>5 / 2.40 I 60 1 0~L GO 33 ji^L~ boo 2- IS 1 53 ;o? 73 49 31 \%.b 10.0 s.a 76 35.6 /D,& /o 2.0 2>0 HD 50 GO 70 30 3 /,-2_ 106 IO z. 3 S G 7 5 ^7.2. 12.3' 25.6 36.447.0 57.2 66,5 75,6 sy,5 23,4 10 0 ... - 23. if ' /o 2 3 y 5 6 MONS 049816 7 8 31.2. lob. 93,1/ 90 20 " 20 92./ \ Monsanto . '* .m*m iocat.on, Q, L. Arnett PR&D - Anniston NCrtftCNCL December 26, 1968 VISCOSITY AND SPECIFIC GRAVITY DATA RELATING TO AROCLORS 5060 AND 5460 TO : V. R. Haupt cc J. C, Landwehr G. W. Miller H. L. Williams J. T. Bell Below is a compilation of data requested by you regarding vlacoalty and specific gravity of Aroclors 5060 and 5460. Please advise me if you require further information. Material Aroclor 5060 Aroclor 5460 Aroclor 5460 Aroclor 5460 Aroclor 5460 Aroclor 5460 Aroclor 5460 Aroclor 5460 Aroclor 5460 Material Viscosity Speciflc Soft Point C Temperature C (Centlpolse) Gravity fa/ec) 114 170 233 104 140 781 104 150 316 104 170 66 104 200 19 100.5 200 18 104 140 104 200 1.530 1.475 100.5 140 1.544 G. L. Arnett /bs IM'IO I*tV MGNS 049817 sxarbau mimcntzm nociu m AUCLOt i?rmm c - mticAi. wwaiiii or mump coops. nnwMtw. mum coopa Aroelor 1221 - Rot Available Aroelor 1232 - Rot Available Aroelor 1242 Aroelor 1248 Aroelor 1234 Aroelor 1280 Aroelor 1262 Aroelor 1268 - Rot Available Aroelor 2365 - Rot Available Aroelor 4465 - Rot Available Aroelor 5442 - Rot Available Aroelor 5460 - Rot Available 1AW KHimu lipkayl Santovax - lot Available Santovax 1-Rot Arallbl Chlorine Hydrated Llaa Attapelgae larth-Rot Avail. Rerrle Chloride HONS 049818 PHYSICAL CONSTANTS DATA AROCLOR 1142 (Technical) STRUCTURAL FORMULA TCHPILltD SV-.--' DATE 1947 Poraila Mslec^lar V.'eici'.t NAV.E C.-H.Cl "` ^ roilin Polii: st 7S0ir.n F..,.:ii;.tPoir<t *t nn r; ET.S1 ?ci:; ii rr.m C: it'Ilizir.*' Point Total C1.41. 5 - 42. 5% Brown to black oilv liauid SOURCE ft DATE Specs 12-21-54 SDecs 12-21-54 r.ii-.i-a ___________________ _ Ascitic Gn:o5/15.5uC Sitciiic ?5/l5.5fi CciiiiL..; c.1 l-.pnr.sicn ;::vj ..via J aS i.wil (Reference) S::ctru.Tl (Raftirence) 1.348-1.360 1 384-1.337 in r Specs 12-21-54 ''liiMiWt______________________ fv!t?sT6-..-,n SsWliiYin'.'.Mer toh^lRv in - Solubility in ' Sr.fir.Temp fioeff. 150- 105UC1 0 00Q9/C Specs 12-21-54 Fl'sb Poiiu; -F tiinhod! C. O. C. Fin Paint C JiMt cl Ctfcfisn I!;:.: of rcrn^Mcn ViMil S: ;!;!;v (ctl.An/min.) U'ttt&ti'fVhL Sbscifl: Ft:.: Critical 7wt CiiM ?w: KtwtSta Caattst 1 350 None Aroclor Bi^l. OP-115 lfl5i HONS 0*9019 Toxicity (Give Rifcrtnce) N07-: : ahould not be r Schwartz. U. S. Pub^Healtm Service Bull. #229 1936 "Industrial -Poisons.. Hazardis and SSolvents1* bv MLB. J3^o^Sii iufi ii.9A t thoott 1/ noeettoiy. aIN PHYSICAL CONSTANTS DATA ES.iit.ii ...... ..... TRUGTURAL FORMULA AROCLOR 1148 /Technical) jvt1 rj.1; oxn 1.947 O-Q >, i-;v A. V. EUenbure NA.\;s :..;'sc::!Er V.'eiBht ' ` ... lia .v;k 7EQ rn____________________ f.t r*i : 1' * rr O ' f' r 1 1 ;u Fo;r! 7/5/57 Total Clj 47.5 - 48.5 % - : ;' .irown to jilao'toilv liauiu EL, SOURCE A DATE Snecs. 4/11/S6 Soacs 4/,1/55 -.1 3:: * 65/15. 5 1.410-1.420 tZiL-'id - .___________________ o =C .IZJi________________________ Ca;:5c:.:.. C csu'.s::.i "S '.ij S '.io.ua {R*i-jrx.j_ Jilra V!tL: S:;c!icn tn.lcrmc.) Vteetiw 9 VltMiilv a Soecs. 4/11/55 ___________________________ ?. v Sa. C-.-. Tamo. Coeif. (50-100C) 0. 0009/C Soecs. 4/11/45 1 ' r.:..>:`.2i?euuo C.O.C. -C 382 None s:!;i . . 7 ;:7;7;vto:./.;Vc5,l L': ClSlK' "..V-HidC* Crlt'v Aroclor Bulletin OP-115 " ( 1954) ! . HONS 049820 J~-- SI.......... i i`l _ 5! ' 1 Tc::!ci! K!m RtUnnu! Schwartz. U. S. Pub. Healt i Service.Bull.iZ9^ 1936 . "Industrial PoiSOT ,s Hay,arris fa Solvents hv NC72: niH.de.u.ihouU not i toloaood M. outoido Bof.MJaanscoontbo sChVtmoic.tU1,Copm.pa4n6y.3U-4to3a4dditi1o9na4l1im, iIi if noetitary. C3lr PHYSICAL CONSTANTS DATA AROCLOR 1154 (Technical! TRU ETON Ak FORMULA O-Q Smm ce Mrrmnri-- ------------------ ir;i'.-.jIii .v A . *VT 'TMhrr.burp ,\Af/Z Ci Cl- ^ 6at* i947 7/5/57 Total CU 53. 5 - 54. 5% cte . SOURCE A DATS________________ ,, Sper<i 12-S1-54 i,"LL'^ ICi__________________________________________ 1 Brown to black oilv tiouid rv-'vi \ 760 rn______ =4 Specs. 12-21-54 rv - 0.:^. _ rr C,'Si,.:!i:i.v r;,r.t C*ji `i'?. 1.500 - 1.510 i;..j C CotiVi.'.ii.'t c.` & 2C'J70 c# nS i !si t:^C.rum /V^.vrcr.ce; 4' i Violet SoCCu'^mI (p.c'crcr.ce) ;> V.5Ck-2..V <y T'"$: Vy filihilit" ir. ... S;!A!!'.`.vln n Sc. Or. Tsidd. Cceff. (55-105C) 1? fi 0.00095/C ~ Rein: mahoi) T.a Pd.'.i J0 Vh.-r.-i! Siai.Mcd./:^!!) L.;a`. a?-- t; r'-sito l.r -r:t Rm' OisMJhilca None None m (9 a ... O HONS 049821 ------ O .... (Civj Reference) Schwartz. U. S. Pub. Healt i Service. Bull. #229,1933 "Industrial Poisons. Vol. 1,-463-364 1941 ' la should not he released oufl^Zef %eianto^^jnutaf8ompan]r. Mi luftHionat^sfMets if metisary. X 0 V 2: These da; Gin ill PHYSICAL CONSTANTS DATA _______ AHOCLOR 1160 (Technical _ . L :~-`-.cr.rT77Z DATi 1947 C^.,25 . "-jv A . 'ilanburs 7/5/57 aa.v.z fi.'Uia_____________ C19K3 7sClfl_ 35 ;c:iir.i".u>t Total Clp 59.5-60,5% Brown to black sticky mat s SOURCE A DATE Srificv 1 9.-?.] -54 SDecs 12-21-54 ?.T.:a: 763 a 0.-. 2: ?oi:.t . ., ; , ... C*-. rv.4Vr:: ?,;> 90/15. 0 C;:.'.:y >-. C C.'v.Vicic'.. lnoct.s.zt: --:< "S f:... S'.CCA'UmI fR.derenee) ''iClL ^.ctrur.1 {Reftrenes) 1 558-1.572 .-L3...5 - Soecs.12-21-54 ' :i!;t7 In !t..'.til!tv in Sr,. Or. VamD. Coc-ff. (75-130uC) TT. 0010/UC Specs 12-21-54 * !'M0xi) Pci:.: "0 i' C:-i'jvs.:sa sf Fermion ' V! StfSi!iihd/i!/'in. . Hat 0! Fib!m HttldVn. fr :-tllk Hast Ci'.'icsl Tadwwtat Ctfcsl Pusjna Dissndstim Ccnstrnt Nnn# None MONS 049822 ___ (9 VI OSt O O Tc;:icitv fCive Roforor.ee) Schwartr.. U S. Pnh. Healt Service Bull. *2?9. 19.76 "Industrial Poisons,,Haza ^ds and Solvents" bv M. B. 0 T E ( These dqta should not bo rsteased aut^Ji^of %onsantb Company t* additional shoots If noeossary. PriYiSiCAL ClOsSiS TAn f3 uaYa AROCLOR 1162 (Technical! Y---------- dats Ty47 structural formula O-Q cu SAMS rCJidl_____________ Cl ?HnCU_______ Total Cl3 61.5 -62. 5% SOURCE & DATE ____ F i'.lir' Pair.', il 70ff.s ti",!!'.:'1. ?r,!r* ;* irri Rrown to black sticky mat s Spec 4-11-55 r- Oo.'f,( u. .' ___________________ __________1 C________3/IS 5 1. 577- 1.587______________ 13.7 Ciw.'.1. ^C`>* C.'Oc,1S!C- ;;:::;.:iivo >',iS $jcc. #2 Uiifii Violet V;Sf.\:*V .- sv ^3i v ir.... 1st___________________________ In r-. ''ftsipCcAff. /83-120C> 0. 0010/C Soec 4-11-55 SDec 4-11-55 .*&{? :::y *c ;! cwi .. 7 ..|cn Nrn< -- > (> u5 o e MQNS 049023 ToxicitY (Give .le.'crenco) Schwartz. II S Pith Healt firrvira R.iil Ifl.Ifi ' ' ladu siriaLP q 1 s pop. flazax js a id Solvents" bv M.B. NOTS:.rA* rfoio should not be released outside < tddUional sheet* if necessary. HONS 049825 HONS 099826 A*DCitf ll&i-IO'V''*. > Sm>*<h F,h inw< (., $fn< >. *.*-i-S'fca- */i `c 12.7 ie3.3i.(.*rr58j>i**> VS*k*i<.*v 0**t/< 4.V <> JUS)Z!0' U M*t a .rtWtN.f Uw A*V Avc. ;4 S*X' h *<><>( Jl'i Jo*4vT In 24-Jt HFHm|t o><< FCt9****0*~*-..N 1 i*T|N* Amt c< m*n* *. i4fCw|tn.< 7Mi|i>Jur(tt I^AH P* )} E WS f*<. -'tl!0 W5< 71.,*. -3-.03 a: -71.*-* >?im* * i -ac.r* '.-- w -t*4.44 v-, 2 a- _ Ft* t 1 f-4fc 7fc.t a*.*. 2 R* PINT 5iii*t 6**t Setvt'M* U Mt'K O'C Qrtvfttl0T4t'*CC CMevt.4 -i IsIBWAt Co-3*<tAkf Ml-.ul*; 5M C" UNVl, 5*V> ' Viw.'vi iSS'C ?"-** --iA*, MalNNt Ma 5.*** '4** St tpa* rci 84.T C (04 14*2 2 -" 7*-'0 ftuit Itt NI'.lt* Cfl* " ' n*>'i k-.ti ' 't*C C`.-44 --/<*C * i*`-7 7'*C lowaC^vnj* fce C*.t,-_.., ~- ' S. * -.4lY*A S ClVOXIII 2.2 - 2Cc 4 *- 2*C i.';BiZ * 77.1*6 Ut '^n *01.574,1*1.545 0**4 Cf*. * *. 5 * ,, .. fie- S !' 4 *1.* 3*. . V*r`t feaaF>a*>77* 31.2 Vt . rt ** 2V5*- >*4.2'C I*. C*., !v *ii D* >48) 'Sif-'-Js v. $4'.a *4 V .. r.i ;*> c. J ;4 ' -fC** 2's 0-*. '*. a-,.. ..*<*.* ; *' U((hU *a.32.M2 S*~.H 'V* (*. .) > -0*C 8*.4 S3.i J**/-k .* 4 i:fr.5 ?*/%. 2SS*c S*-a 5.43 */;** Ml 64444 *** *St-4Jfa'*t* A*v <. ml.ei> I""M! 1**^% __ WM 9a , H-*. 4-> l.5tO-l.34*.r4.Wn.S. " * >.o* . , *" a**i 6j. * ' L*M7-'4ST 2 3 *c '* W5*svs tec*F - - I&CV 2 9 * C *.7 >.....** ?. fa 1.14.25-90*6 R*."7 t o* .0711. V ,o*C 5,.. . a. si *:> 7,Cl Rt* 4 -52'c 4. fa V)-i. o 2o io''.- 5c'c >> Res-7 ) 0. 'tLl *.T41A|r,*C*4T 0* 3# ?.t*, '4J-? C>*'.* >44 0 0*r. JbSRji *8t46 l-Caav r*a 0t- O.-a t*9<4C rntttt 3 - Flan-S.i<- C.ta c<. T4 i !*'5D**a >** BMElKl S Iaa*iO 8' Vt-On rcSt* fc-S*ttv t-fc-5S jArtMac.* 7C---s** im. 1T1XS _______________ - i AlAFMTun mjutr - MOWSAFfTO COMPANY - aimwom. aua. AWTH. MOl jom mo. rs-B - HONS 049827 General Properties The Arodors range in form and appearance and Aroctor 5460 is insoluble in the lower from mobile oily liquid* to fine white crys molecular weight alcohols. Aroclor 4465 is tal* and hard transparent resins. They are only partly soluble in the lower aleoholr- non-oxidising, permanently thermoplastic, of low volatility and non-corrosive to metals. They are not hydrolysed by water, alkalies or acids. The viscous liquids and the resin* will not support combustion when heated alone. The excellent electrical properties, fire resistance and inertness of the Arodors make them useful in many applications. The properties imparted by the Aroelors and their usefulness for particular applica The crystalline Arodors are relatively insol tions vary in regular gradients over the uble, but the liquid and resinous products series so that the selection of the right are soluble in most of the common organic Aroclor for a specific use can generaltv be solvents, thinners and oils. All Arodors sre made simply by a comparison of the physi insoluble in water, glycerine or the glycols, cal properties of the several Aroclor*. MONS 049818 3 MM GINERAL PHYSICAL PROPIRTIII Fo...................................................................... .... Aroclor 1221 Cnlorleaa mi>- Idle oil Colo*................... ...................................... . . 30 Max. (APHA) Aroclor 1232 Aroclor 1242 Arcolor 1248 Practically Practically Yellow tinted colorleu mobile colorless mobile mobile oil oil oil 60 Max. 100 Max. 100 Mn. (APHA) (APHA) (APHA) Light ysBew ISO Mas. (APHA) \cipity--Maximum (Mgm. KOII per Cm.) 0.015 0.015 0.015 0.015 0.015 Averao* CoimctiNT or Expansion.................................................cc /rc,'C Typical Dbnsity Siwrifl. Gr.vllr 2S725*C (77*/77*F)........... Pound. pm C.llon-25*C (77*F)........ ......... 0.00071 (15*-40*C) 1.182 9.85 0.00073 (25*-100"C) 1.266 10.55 0.00066 (25*-65"C) 1.380 11.50 0.00070 ' 0.00066 (25*--65*C) (25*-45*0 1.445 12.04 1.538 12.82 Diutillation Hanoi--ASTM D-20 (Mod.) Corr.'C........................................................... .......... 275*-320* Evaporation Loaa--%--ASTM D6 Mod. ion:....................................... 5 hn. -- lOO'C............................................................ 6 hr.. 1.0 10 1.5 V i AAii Point--Cleveland Open Cup-- C. 141*-150* F 286*-302 290*-325* -- 1.0 to 1.5 152*-154* 305*-3l0* 325*-360* 3.0 to 3.6 0.0 lo 0.4 176'--ISO' 348*-356* 340*-375* 3.0 to 4.0 0.0 to 0.3 193*-196* 379*-384* 365*-3 U to 1.3 0.0 to 0.2 Fink Point--'Cleveland Open Cup......... ...*C 176* F 349* 238' 460* None* None Pm * Point--ASTM D-97...................... l'C *F Crystals al SorriNiNC Point--ASTM E-2S............. ...*C -- -35.5* -32* - -19 2 - --7* 19.4* - 10* 50* - Ultra active Indsx--D4lne--20*C......... ......... 1.6171.61ft Vmciwm--Savbnlt Universal 5lO"F (08.9*0 30-31 SW. (AS l'hl--Il-W) 1J#.F (54 4.C) JS_37 100'F (37.8*C) 40-42 1.620-1.622 31-32 39-41 47-50 `NONE Mfcwtas--"No fip#i point up lo boiling temperature" 4 1.627-1.629 34-35 49-56 80-93 1.630-1.631 36-37 60-78 185-240 MONS 049829 1.639-1.641 44-48 260-340 1800-2300 I OP SOMi OP THE AROCLORS Aroclor 1260 Uglil yellow tort Micky ratio ISO Mat. (APHA) 0.015 Aroclor 1262 Light yellow sticky clear resin 150 Max. (APHA) 0.02 0.00067 (20*-100*C) 1.620 13.50 0.00064 (25*-65*C) 1.646 13.72 120* 0.5 lo 0.8 0.0 lo 0.1 None 400*-430* 0.5 to 0.6 0.0 to 0.1 None None 31* 18* None 37* 99* 1.647-1.$40 72-78 3200-4500 1.6501-1.6517 90-103 600-850 (HOT ..71*0 Aroclor 1266 White opaque resin 1.5 Max. NPA 0.05 Aroclor 4465 Yellow transparent brittle resin 2.0 Max. NPA 0.05 Aroclor 5442 Yellow trans parent stickv resin ` 1.5 Max. NPA 0.05 0.00067 (20*-100*C) 1.810 15.09 0.00061 (25*-65*C) 1.670 13.91 0.00123 (23*-99*C) 1.470 12.24 435*-450* 0.1 to 0.2 0.0 to 0.06 None None 135* to 160* (hold pt.) 275* to 320* (hold pt.) _ _ 230*-320* at 4 mm. Hg. 0.2 to 0.3 0.0 to 0.02 None None 60* to 66* 140* to 151* 1.664-1.66? 90-150 IWfi* l*C> 21S*-30G* at 4 mm. llg. 0.2 0.01 247* 477* >350* >662* 46* US* 50* to 61* 113* to 122* 300-400 _ Aroclor 5460 Yellow trans parent resin 2.0 Max. .NPA 0.07 Aroclor 256ft Brown*blRck opaque ratio M 0.00179 (25*-124*C) 1.670 13.91 n.nom (2J*-65'C) 1.734 14.44 280*-335* at 5 mm. l(g, 0.03 1.5 to 1.7 (t te*~i w i None 0.2 lo 0.3 None None 100* to 105.5* 212* to 222* 1.660-1.665 None 66* to 72* 149* to 162* HONS 049830 9 TABLE ft--Resistance of Structural Materials le Arodors Meult 25*C Aluminum.................................................................... Copper.......................................................................... Magnetlum.................................................................. Nlekel........................................................................... Sllrer............................................................................ Tin................................................................................ Zina............................................................................... MUd Steel.................................................................... Phoepbor Bronae........................................................ Red Braai.................................................................... Slalnleee Steel (Type 316)......................................... Yellow Bran............................................................... R R RR RR R R R RR R D RR R Plailioa Alkyd Roaln No. 46594-12........................................ Alkyd Roele No. 4659t.UA..................................... CalluloM Acetate (Flbeetoe)..................................... Durile Phanol Furfural Realn.................................. ftrmrar Highly Plaatlelaed..................................... Formvar Low Plaitielaad.......................................... Glyptal 1ST*................................................................ Glyptal 7IS6................................................................ MoMo Raaln No. 46594-15B.................................... Matate Realn No. 46594-13C.................................... Plaviglaa (Methyl Methacrylate)............................. Polyetyrenc (Luairon B)........................................... Reeloox Miuoral FIHod Mrlemlne Raain................ Reeloox Wood Flour Flllod Melamine Raaln........ Reeloox Mluaral Flllod Phanol Formaldehyde-- Reelnox Wood Flour Flllod Phanol Formaldehyde Reelnox Rag Fillad Phanol Formaldehyde............ (Jroo Formaldehyde Raaln (PUekoe Co.)............... *P *D D *0 Da PS R *D P P *D P *D *D aD *D *D *D 1 125*C R D R R R R R R D D RR Re P P P P T T P T P P P T P P D P D P Aroclor Numbcr 1254 25C 12$`C RR RD RR R RR KR RR RR RR RR RR KD RR RR n De P P D P DP R P Pa T PS T DP R T *P P R P D P PT n H ii D D I) D Ml D D D P 446S I25*C RR n KK RR n K K R It It RR Re P P P O T T P T P P P T P R R D *0 P 5460 12$*C RR D *RR R R R RR RR R Da RR Re P P P P T T P T P P P T o P P P P F Moaning of AhbrcrUIlona: *--Boaod on waifht goIn ealoulatad aa penetration value ahown. RR--EaoaRonl raalilooaa laaa than 1.0 x 10** em/day panairatlon or .00014 m/r, R--Good raalalonoa boa papairathw between 1.0 a 10-4 and 10 a lO^om/day or between 0.00014 and 0.0014 im/jr, D--Doubtful reeieUocc, paaatration batwaao 10 x 10~* em^day and 100 x 10~* cm/day or between 0.0014 and 0.014 in/yr. P--Poor raeietanoe--penetration greater than 100 x 10"* cm/day or 0.014 in/yr. PS--Poor reaialance due to rialble local action although weight ehange indleatea greater reaiatanca. a-Following the letter indicating raaiatanea elgnifiee malarial mar ha better than Indicated if totally immaraad alnee weight loaa la beliarad to eome from oxidation of the part of teat atrip axpoeod to air. T--Material alone will not aland temperature. MGNS 0*9831 ADHESIVENESS The Aroclor resins ahdere strongly to smooth surfaces, such as glass, metal and varnished or lacquered coatings. The softer Aroclor* are indicated where a flexible non*drying, water-resistant strongly adhesive ma terial is required. The Aroclor adhesives are thermoplastic; are readily applied hot without solvent; do not require high temperatures for easy application, ana are set immediately upon oooling. SPECIFIC VOLUME The specific volume of Aroclor 1248 at different temperature# ia as follows: Temp. *P Aroclor 1248 Specific Volume mt/gm 0 0.674 100 0.699 200 0.726 300 0.755 400 0.790 500 0.828 600 0.870 FIG. I AVERAGE COEFFICIENTS OF EXPANSION, AROCLOR 1248 The average coefficient of expansion of Aroclor 1248 per degree F. within the various temperature ranges indicated in the table below was deter* mined by urine the simple formula Vt Vt' Tl+a (t - tl)J, The coefficient, a, has been calcu lated at lOCrF increments, as follows: Temp. Range F 0 to 100 100 to 200 200 to 300 300 to 400 100 to 500 500 to 600 Average Coefficient of Expansion cc/cc/ 0.00037 0.00039 0.00040 0.00046 0.00048 0.00051 CORROSION The Aroclore show practically no corroaive effect on metals within normal ranges of temperature. They do attack many plastics materials of eon* struction aa shown in Table II. TtM^e/Mraxe Deletes C T MONS 049B32 FIG. 2 HONS 049833 DENSITY All the Aroclorn are heavier than water, valuable property for maoy application*. Densities are shown in Figure l. ELECTRICAL PROPERTIES The Aroclort have extremely interesting electri cal characteristic*: high resistivity and dielectric strength and low power factor. The dielectric con stant ranges from 3.4 to 5.0 at 100C. and 1000 cycle*! depending upon the particular Aroclor. The dielectric constants of Aroclors 1242 and 1254 at venous temperatures are shown graphically in Figure 2. The electrical properties of the Aroclors are shown in Table III. NON-DRYING PROPERTIES Tite Aroclors are non-drying, and when they are eipoecd to the air, even in thin films, no notice able oxidation or hardening takee place. How ever, when ueed as ingredients of lacquers, they do not retard the rate of drying of the lacquer films. Quick drying vsrnishrs and paint* may be made with Aroclor resins. NONFLAMMABILITY The viscous Aroclor oils and the resins do not support combustion when Iteated alone, even at their boiling points -- temperatures above 350*C Most of the Aroclors flux readily with resinoui and pitch-like materials to give a product hav ing a decreased fire hasard. When incorporated in nitrocellulose films and rubber foams the Aroclors retard the rate of burning. SOLUBILITY All Aroclor* are insoluble in water. Solubilities of some of the Aroclor* in the more common sub stances are shown in Table VI. The Aroclor oils and resins are readily soluble in most of the common organic solvents and drying oils. The hard crystalline materials are in general lea* soluble than the Aroclor oils or softer resins. Compatibility data on Aroclors in nitrocelluldse lacquers are abown on page 18. SPECIFIC HEAT AND THERMAL CONDUCTIVITY The specific heat at different temperatures of several of the Aroclors is shown in Figure 3. This* together with the thermal conductivity data given in Table IV, enable calculations involved in the uee of Aroclort as high-temperature, low pressure, fluid heat-transfer media. TABLE III -- Electrical Properties Dielectric Conetent ii 1.000 Cycle* (1) Aroclor 25*C I00C Volume ReeietMly (i) Ohm--cm *t 1O0*C, 500 Volte D.C. Dielectric Strength (3) 1232 1242 1248 1254 1260 1268 5442 5454 5460 4465 5.7 5.8 5.6 5.0 4.3 2.5 3.0 2.7 ' 2.5 2.7 4.6 4.9 4.6 4.3 3.7 -- 4.9 4.2 3.7 3.3 Above 500x10* Above 500x10* Above 500x10* Above 500x10* Above 500x10* Greeter than 35KV Greater than 35KV Greater than 35KV Greater than 35KV h'aclor (4) 100*C. 1.000 Cycle* <0.1% <0-1% <0-1% <0.1% 0) ASTM D.150-47T (J) ASTM D-257-46 (9) ASTM 0-149-44 () ASTM D-150-47T MONS 049834 9 CALORIES ( 1 5 * 0 PER GUAM PER *C F1C. 3 hiat capacity of aroclors at crtout t%m*9rmtvr+* TEMPERATURE *C TtAhIV Thermal Conductivity of Arodor 1240 T*mpriUN HTt 7Hr7/^q. Ft./ Cslnrim. gram/fee.' C. *F._______ T./fi. Sq.Cm.7*C./Cme 30 90 0.0680 281 x 10"* 60 140 0.0687 284 x 10" 100 212 0.0697 288 x 10" STABILITY Toward Alkallt* Tile Arodor* ore remarkably re*iiant to the action of either hydrolysing agent* or high tem* pcraturc. They are not affected by boiling with sodium hydroxide solution. Toward Adds Kxjienments were made lo dricriuine whether hydrogen chloride i* evolved during the treat* ment of Arodor* with sulfuric acid. Arodor 1251 (selected a* typical) was stirred with an equal voluine of ten |>cr cent sulfuric acid for a period of 150 hours. Any gases escaping front the reaction Hask had to pass through a trap filled with silver nitrate solution, which solution would give a preripiute of silver chloride if any HCI came in con tact with it. After 150 hours of treatment, neither the trap solution nor the arid Isyer in the treat ing flask showed any hydrogen chloride present. Kvcn prolonged treatment (255 hours) with con centrated sulfuric add indicated only a slight trace (too small for quantitative measurement) of hydrogen chloride in the acid layer. Toward Hoof Because of their stability lo heat, the Arodor* are useful heat-transfer media. Arodor 1254 and particularly tlte less viscous Arodor 1248 are recommended for this purpose because they may be heated at temperatures up to 3I5*C (600F) in a closed system for long periods without appreciable decomposition and are at the same lime nonflammable. Toward Oxidation Wlien Aroclors are subjected toa bomb test at 140*C with 250 pounds oxygen per square inch oxygen, there is no evidence of oxidation as judged by development of acidity or formation of sludge. SURFACE TENSION The surface tension of Arodor 1254 ill Jmics per centimeter is as follows: Temperature Surface Tritium--. Ivite. cm. .'3C BO-C I00C 30.3 44.0 42.0 THERMOPLASTICITY The Arodors are permanently thermoplastic. They apparently undergo no coiHleusation or harden ing upon repeated melting and cooling. The dear Arodor resins are now being produced with soft ening points up to 105C. The opaque crystalline solids are produced with initial melting points up lo approximately 290C. HONS 049835 10 TABLE VI--Solubility of Arodora in 100 Millilitora of Vorlout Solvent* T^|te of Snl' Aroclor 2S*C 1248 23*C Hot 1254 25*C Hot 1270 Cold Hot Arctic Add,,........................ 3 3 Oleic Acid.............................. S S Brnnok Add........................ 10.0 *c -- Aldehyde Ml1! Formaldehyde.............. Furfural.................................. Amine I VS f VS 1I VS vs I vs I SS Aniline................................... S S Pyridine................................. 132.5 r. 440 **' __ 114 n*c 42S im*C C.Moro--derivative* Amvl rhlnride*--mixed........ 3 S Carlton Tetrachloride.......... Chloroform............................ S S S S 3.7 iHchlortithvlen*.................... -- Ethylene Dlrhloride............ S -- S 3.0 Monnchlnrolteneene............. S Orthodlchiornhriuene. .... -- S -- 2.9 Tetraehlnrelhane.................. 3 S THchlorethane...................... S S Trieiilnrethylene................... S S IIrving Oil Tune Oil................................ 8 8 l.lnaeed Oil............................ lA<ff 3 S Amyl Acetate........................ S Butyl Acetate....................... S - Cellbwdve Acetate................ S Cotloneeed OH...................... 3 IBbtityl Phthalate................ 3 Diethyl Phthalate................ S Ethel Acetate........................ S Ethyl Lactate........................ S Ethylene Clycol Dieeetate.. 3 Methyl Aeetate.................... S Tricreayl Phoenhate............. S Ktheri Ethyl Ether.................. S Ether Aloonol Carhitnl.................................. 324 397e*c VS vs 173 *c 259 Olkmnlvt.............................. Dlelhvlene (Jlveol .............. s S ss s5 - p-p' Ifthydroay Ethyl Ether. 16.9 Hydrocarbon ' Henaene.................................. VS Caanllne................................. vs Kemaena................................ vs Mineral Siiirlia...................... vs Paraffin.................................. 2.0 Pine Oil.................................. s Toluene.................................. vs 19 w*C vs vs vs vs s s vs SS SS VS vs vs vs 2.0 * VS vs vs vs vs vs s vs vs 8 w*c VS vs vs vs __ s vs 10 ne*c vs vs vs vs s s vs " 3.5 _ ____ Turncntine............................ vs vs vs vs vs vs _ Xvlene.................................... vs vs vs vs vs vs Ilvdroxv--derivative* Amvl Alenhnl........................ s n.Hutvl Aleohol ................... s Klhvl Aleohol (3.A)............. 23.5 ***c (llvecrlne..................... . .: 1 Methvt AWoltol.................... 12.5 tre Phenol--90%........................ 194 ***'K Pinna s 8 80.0 w. I 88.5 ere S -- ._ ss s s ... I0*rc 28 **c _ _1 1 | I lS***c 22.2 wx -- -- SS S __ _ 1 Acetone.............. Mlacelleneou* Carlton DlanMtle 8 Nilniltcnaene. . . Hater................... I- . S 1 S -- Soluble I SS -- Slightly Soluble VS -- Very Soluble Figures ahow grama of Aroelor |>cr 100 millllitera of solvent at 2*C unleaa otherwise indicated. " _ _ ___ _ _ -_ _ _ 1 - 4465 Cold Hot SS s s vs TI vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs vs VS' V3 vs vs vs vs vs vs vs vs vs vs s vs vs s s vs vs s vs vs vs vs vs ss SSS - vs vs vs vs vs vs vs vs SS 1 ss vs vIs 5460 2S*C 113 178 11 HONS 049836 FIG. 4 1.7 1.0 1.9 20 2.1 2 2 2 3 2.4 1000 900 800 700 600 500 400 300 200 20 10 9 8 7 6 5 4 3 2 V MONS 049837 FIG. 8 tempeeatupe, Degrees Fahpemhe/t VAPORIZATION LOSS The low veporisatkm low of Aroclors is indicated in the following Table VII. It it concluded that the vaporisation rates of Aroclors--especially 1254 and 1260 which are the most widely used members of the Aroclor family In lira plasticiser Held, compare moat favorably with the similar constants of other plasticisers selected specifically for these tests because of their low vaporisation rates. VAPOR PRESSURES The vapor pressures of several Aroclors are indi cated in Figure 4 over tbe temperature range, 150* to 300*C. The following estimated vapor pressures of several Aroclors at 100*F shown in Table VIII were determined by extrapolation from tbe veluee shown in Figure 4. HONS 049836 13 TABU VII Vaporisation Ratal SxmpU Aroclor 1221.............................................. ................ Arodor 1232.............................................. ................ Aroclor 1242.............................................. ................ Arodor 124*.............................................. ................ Oorafin>42-S.............................................. ................ DOP (dioctvl phihalate)...................... ................ Dutrax 25................................................... ................ Arodor 12S4.............................................. ................ Dutrex 20................................................... ................ Aroclor 1262.............................................. ................ Aroclor 1260.............................................. ................ Aroclor 4465.............................................. ................ Arodor 1270.............................................. ................ Aroclor $442.............................................. ................ Aroolor $460.............................................. ................ Tricrwyl phorphato................................. ................ Wi.Lom Cm*. 0155 0.2572 0.0995 0.0448 0.0745 0.0686 0.0256 0.0156 0.0047 0.0059 0.0026 0.0064 0.00*5 0.0059 0.0052 0.0010 Hoar* Expotur* 24 24 24 24 48 48 24 24 24 24 24 72 72 72 72 24 Suriiii Arm Cm* 1515 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 12.28 Vaporlsatloa JUt gim./cm.%r./100*C 0.00174 0.000874 0.000558 0.000152 0.000126 0.000117 0.000087 0.000053 0.000016 0.000015 0.000009 0.000007 0.00000$ 0.000004 0.000004 0.000003 TABU VM Approximate Vapor Proiiuroi Calculated al 100 P (37.1 C) Arodor 1232... Arodor 1242... Arodor 1248... Arodor 1254. . . .......................... 0.00006 mm. Hf. HUNS 049839 14 HONS 049840 TMMsi) numerous nociss rot AI0CL08 imataa - mumt The followlug is i Hat of utllltlof auppllad to tho Aroelor Dopartawnt: asm Staaa lo auppllad to tlio dapartnant through > 6" aala at 120 P8IO. Standard praetlea on ftaaa it 137.5 lba/ewt. Liquid Aroelora, 239.5 lfca/ewt. 8olld Aroelora. Recovered Watar Recovered watar la auppllad through a 6" aala Iron a cooling tower. Standard praetlea la 625 gala/cwt. Liquid Aroelora, 1,197 gala/cwt. Solid Aroelora. IloctrleltT Slaetrleal powar la auppllad at 440 aolta for pooar and 110 volte for. lighting. Standard praetlea la 3.25 XM/ewt. Liquid Aroelora, 7.19 SMI/ewt. Solid Aroelora. natural Caa Natural gaa la auppllad through a 3" naln at 40 palg. Standard praetlea la 0.1625 MST/ewt. Liquid Aroelora, 0.5389 MCT/ewt. Solid Aroelora. HONS 049841 HONS 049842 8TAHMW kahupacuiim pkociss FOR AROCLOU AFFMPIX I - PRRSCHHBI. Th Aroelor operations require on* Chief Operator, Claaalfleatlon A-2, and four Operatore, Classification A-4, par ahlft. The chief operator la In charge of all Aroelor oparatlone during hla ahlft. Ba la alao In charge of the Biphenyl group of produeta. A relief chief.operator relieves a regular chief operetor one shift par weak, and an operator four ahlfta par weak. Ha alao works for the regular chief operator during vacatlone, alcknass, and other abseneae. Each operator la assigned a specific Job and la rasponelble for the operation of hla Job. Thera are tan (10) laborara, Claaalfleatlon A-8, employed la tha Aroclor-Blphenyl group of dapartaanta. Bach ahlft hae a ninlnua of two laborara while eons ahlfta have three laborara. Approxi mately 60X of all laborara' tine Is spent In Aroelor oparatlone. Tha laborara' duties consists of filling drums, bags, crushing, screening, and Billing of various products. They alao clean tank cars. The Aroelor Departnent la supervised by a Production Supervisor and a Production Peraaan. Attached la a Job Classification Schedule and Schedule of Hourly Wags Katas which alao shows length of time required between automatic rata incraasaa. HONS 0498H3 JOB CLASSIPICAIIO* SCBBDU AMD SC8ED0UE CP BOBU HACK KARS AUTOMATIC EAR IMCKKASB CIRK AT HID OP: Appendix A October IS, 1965 Department end Claaalflcatlon Probationary Period Starting 12 24 Kate Weeks Wka. 32 Wka. AO Wka. 48 Wka. 60 Wka. 72 108 144 Wka. Wka. Wka. 180 208 Wka. Wka. m. Day Kate A, Production Department 2. Chief Operator ----Pilled by upgrading 4. Operator -t - - -- ........................... 3.12 3.17 3.22 3.22 - 2.84 2.89 2.94 2.99 ......................... 2.99 7. Operator Trainee 2,48 2.61 2.66 2.72 2.77-<l)............................................................. 2.77 8. Operating Labor 2.40 2.46 2.49 2.52 .................................................................................. 2.52 Job Shift Kate Day ta t* Plus 7.5X (1) May be employed at any of foregoing ratea when hawing apeclal qualifications. MOhS 049044 HONS 049845 SXAHMU NAaVTACTUUNC PlOCIgg FOR ASOCLOk AFMPg f - ?A*BHK> AMD 8HIPPMC Solid Aroelor* aro packaged for shipment la 41 galloa Fibre drums, 40 gallon galvanised drums, 5 gallon galvanised cans, and In papar bag*. Liquid Axoclors ara paekagad la 55 gallon ataal druna, and 3 gallon ataa,l eana. Thaaa druna and eana ara llnad with ona coat of A & W 4.A laequar. Liquid Aroelora ara loadad Into tank eara and trucks. Tank eara uead for electrical grada oatarlal ara cither alwlnua or alnc and tin lined. All trueka ara atalnlaaa steal. Occasionally non-alaetrleal Aroelor la loadad Into an Iron ear. All tank cars and trucks ara entered, cleaned, and lnspaetad prior to loading. MONO 049046 Matarlal 1221 1232 1242 1248 1234 1260 1262 1262 - 102 Toluana 1262 - in Xylana 1260 - in Toluana A13B3B 3442 4465 2565 Inarcaan pro Inartaan 34201-KA Santlcliar 794 MC8 295 5060 3460 1268 KIEPM* It AIOCLOR PIHISHEP COOPS cmNM* mmi Walahta Lbs. 50 or 520 50 or 550 55 or 600 55 of 600 60 or 600 60 or 600 60 or 600 60 or 600 60 or 600 60 or 600 65 or 675 50 or 450 50 or 500 500 65, 360 or 674 674 600 635 100 100 200 Contalnar 5 Gal. -55 Gal. Staal Orua If II H If t II II II H II II 1 M II II II If M II If II II It H II II II II M II It l II II II II II It II II 5 Gal. 40 Gal. Gala. Drna It II II II II II II 3 Gal. -30 Gal.- 33 Gal . Draw II II II II II II If II II Papar Bat Papar Bag 41 Gal . Flbra Druat MONS 049847 HONS 049848 STANDARD MANUFACTURING PROCESS FOR AROCLORS APPENDIX G - MATERIAL BALANCE Standard and Thaoratlcai uaagea of raw materlala and hydrogen chlorlna produced for aach Aroclor la shown In Figure 3. Plgurea 1 and 2 show the ralatlonahlp between average nuaiber of chlorine atone and per cent chlorine for Biphenyl end Santowax baae Aroclora. Figure A gives molecular weights of the various Biphenyl base Aroclora. MONS 049849 tI HONS 049850 C H tA B iA /A 'T U 'W C h u > j**A1V>.M 1242 1248 1254 1260 1262 1268 2565 4465 5442 5060 5460 Biphenyl Theor. Std. 79.60 82.06 59.19 61.02 53.37 55.02 47.53 49.00 41.71 43.00 39.76 40.99 33.93 39.68 27.63 28.19 22.10 -- 25.86 -- -- HCBOE OP. 3 Theory and SfteJ Bm for Aroclor. Lb.. per OR Aroclor SatoMx l Theor. Std. Sentovex C Theor. Std. Chlorine Theor. Std. "" 42.00 45.16 ---- .. __ __ -- -- 84.00 90.32 __ 96.00 103.23 _ 108.00 116.13 -- -- -- -- -- -- -- -- 120.00 129.03 -- -- 124.00 133.33 -- -- 136.00 163.86 "" 14.74 59.19 17.24 69.23 9.21 --- 9.40 -- -- 130.00 130.00 84.00 132.65 156.63 101.20 41.71 42.55 120.00 122.45 41.71 48.78 -- -- 120.00 144.58 Byd. Chloride Theor. Std. 21.59 za. $~7 t33- d&l 40, l~7 30*80 4*5.30 & mvr bhlD -5fc5X 6>.68 63.35 -694*063.4.5 66.08 66.8*5 4*S* 6/. 70 "o5eB1.U6.4a** 30c0S *59,36 54.18 5S 66.8 . 54=8013.63 3osm S9.23 &,!.bO -60*08 98.15, MONS 049852 MONS 0 4 9 8 5 3 OitTJStM cuecUNMci o'CTzst.cn ca f t *1* a a o d HONS 049854 STANDARD MANOTACTORINO F10CISS FOR AROCLOR APFCTDI1 - ATMOSPHERIC A STRRAM MRCHARgR A WASTE DISPOSAL Tha following la an aatlaata of tha atnoapharlc and afcraan dlaeharga Iron tha Axoelor oparatlona at tha n<-- rata of 4,027,000 lba/awnth. Chlorlna HCL (Caa) Montara _Xxbs_ Atnoapharlc Ataoapharlc Plant Duap Jawait Nagllglbla Nagllglbla Approxiwataly 10X of Total Aroclor Production MONS 049855 MONS 049856 SIAMDAU MMUPACTDKXH6 F10CISS rat AIOCLOk AFFiron I - PMC1B8 CCWT80L H0C8WH18 Control aaaplaa am takan froa tha chlorlnator circulating llna at interval* throughout tha chlorination. Tha aaaplaa ara cheeked, by tha operator, for (pacific gravity, aoftaotng point or hold point dapandant upon tha Aroclor balng produead. Taaperatura raadinga ara takan ovary hour and raeordad on data ahaat. A rapraaantatlva saapla la takan of all dlatlllad Aroelora and aant to tha Analytical Laboratory for control taata prior to druaalng, bagging, or loading Into tank earn or trucka. Tha following control taata ara parforaad by tha Laboratory: Teat (Liquid Aroelora) Annlaton Analytical Method Ho. Specific Gravity 052 Molatura 047 Reelatlvlty 122 Ifft (goU*.Araatal Softening Point Analytical Hathod Ho. 115 Hold Point 119 Color 128 8olublllty 117 A couplata analyala la run by tha laboratory on all final lot aaaplaa. MONS 049857 HONS 049858 CONFIDENTIAL HONS 049859 STANDARD MANUFACTURING FIOCESS pna AROCLOR APPENDIX J - 3Ann & TOXICITY DATA ASP ACCIDENT REPORTS Safety of operations In tha Aroelor Plant depends on tha individual operator. Materials bains handled and oparaeions auat be observed eloaaly to guard against tha followings Causa and Action to Prevent 1. Chlorine Gas Chlorine gaa la a vary toxic corrosive gas. Leaks or high pressure can occur to liberate it. Action to Prevent a. Report Chlorine gas exposure lMedlately for treatment with Antidote. Milk nay ba used in nlld casaa to relieve threat irritation. Oxygan froai tha raeuseltator in tha Dispensary is available. b. Keep gas mask in good condition. Keep a good canister in tha aaak. Use thaaa type nasks only in chlorine concentrations to 2-3X chlorine In air. c. Use a Scott Air pak In concentrations of chlorine gaa above 3% la air. Three units are available in tha Aroelor* Biphenyl Department. d. If caught in chlorine gas without a mask, hold your breath and go cross wind until you are out of range of tha gaa. Place a handkerchief over your nose in snail quantities of chlorine. . a. Report all chlorine leaks for rapalr lnuadlataly. Make temporary repairs with tape if possible. f. In case of a najor chlorine leak, tha source of chlorine gas aust ba stopped. Notify the Chlorine Plant lanedlately If tha pressure on tha chlorine manifold exceeds 30 pslg. Cut off liquid chlorine fron the car. MOWS 049660 apitmix j i 2. Thermal Burnt C>UM and Action to Prevent Contact with hot unlnaulatad product linaa ar the chlorlnatora and (till araaa. Contact with unlnaulatad ataan linaa and open ataan. . Contact with hot Aroclora Iron broken linaa or laaka. Contact with open flanee at atllla or Iron heating linaa In tha dapartnant. Action to Prewant a. Know that contact with equipment and product will eauea a tharnal bora duo wind.to tha high tawparaturaa. Make chaagea in oparatlona with thla hacard In b. Know tha llrat aid treatment for buna. Cold Water Treatment attached. c. Wear glowea and long alaawa ahlrta with tha aleavea rolled down whan operating. Qlovea and clothing ana make the difference between flrat and aecond degree burna. d. Report unlnaulatad llnea for repair of lneulatlon. a. Uee only ataan linaa with hoee and hoae clanpa In good condition. f. Tha following oparatlona are haaardoua and ahould be dona with cares (1) Catching ganplaa at tha Aroclor chlorlnator circulating punpa. (2) Sanpllng tha Solid Aroclor etlll receiver. (3) Drawing bottone on tha Aroclor atllla. MONS 049661 affimsu j 3. Explosion 4. Fall* 3. Cam* and Aetlan to Pravant An explosion could occur In th* chlotinatora by alugging liquid chlorln* to th* dlatrlbutor. Slug* of liquid ehlorlno could raact fact anough to caua* axcasalv* praaaura In th* vassal. A ruptur* of th* ehlorlnator could occur. Action to Pravant a. Obaarv* oparatlon of th* chlorln* vaporiser and do not lat liquid chlorln* get into tha rotamstars. Pip* lino* will b* frosted. b. In caa* chlorln* feed llnas ar* frosted, close liquid chlorln* food valva to th* vaporiser. Check stoaa addition to th* vaporlsor. Do not start up until source of troubl* hat boon located. c. Obaarv* toapsratura of tha ehlorlnator periodically and b* sura It la not to* hot (180C. maximum). Slipping on caant floors, stairs, Aroelor on floor, le* conditions; tripping ovar objects (hose, pipe, valva handlos, ate.); or losing footing on ladders, ate., can causa falls. Action to Pravant a. Tha majority of minor, sarloua, and naar-nlas Injuries In th* Aroelor Dopt. ara tha rasult of fall*. Prevention 1* always within tha ability of the . operator by uaa of export operating practices. HUNS 049862 AFFUDU J 4, 4. Falls (Contd.) 5. rirta Cams and Action to Ftwt b. Tha following ltaas should ba dona: (1) datum hoaa to rack aftar using. (2) Keep operating araas class of all foralgu objects. (3) katura laddata to racks uhaa not in uaa. (4) Kaap glovaa on and hands out of pockats. especially going up atalra. (5) Place guards around any area that prasants a hasard that should ba guarded. c. Poor lighting duo to burned out bulbs should ba eorraetsd at ones. Four lighting duo to Inadequate facilities should ba raportad. d. Spills nust ba cleaned up iaaadlataly following their occurrence, taport any spill that cannot bo cleaned up within tha shift to ths Chief Operator. Spills srs to bs raportad in tha log book. Flraa can occur by; Biphenyl, Santowaz I, or Santowan C Ignition. Chlorine problem in the vaporiser allow* lag reaction with staea to relaasa hydrogen. Furnace burner backfire. Wood, rags, or paper on hot lines. Sparks fron welding apparatus of open flanas. MONS 049863 APPENDIX J S. 5. Flree (Contd.) Cmm and Action to frerit Action to Prawont a. Area oust bo claar of traah or fleasable natarlala. Uaa traah aklpa and eana. b. Smoka only In araaa ao daalanatad. c. Use apark producing agulpaent only with a flra paralt and proper In* apectlon. d. Baa cart In lighting gaa torch or tho till furaacaa. a. Plro fighting aqnlpaant lnelndoat (1) Two wheeled dry powder unite. (2) Hoee hooae with 200 ft. of hoee. (3) Two dry powder band extinguishers On. C02 hand extinguisher. (4) Two 3/4" water hoeee. (5) Hoee connection north of lantewas (6) Scott Air Paka. (7) Flra truck In fire howaa. f. Obaarre ylaltora In the plant and be aura thay obaerwe safety rulea. HONS 049864 AFTUDIX J 6. Cu and Action to Prevent 6. The following 1< a Hat of ehaalcala handlad In cha Aroclor riant oparatlona and tha praoautlona to ba takan during thalr handling: a. Chlorlna Caa Thla la a corrosive gaa which la tosle. Laaka or back preaeure can occur and liberate chlorlna gaa In tha araa. Oparatora ohould have thalr cartrldga type rcaplratora handy at all tlmae while In tha araa. Dae of gaa naaka la explained In Section 1. Chlorlna Caa. If you are caught without a gaa naak, and large anounta of chlorlna gaa are liberated, hold your breath and go croaa wind until you are out or range of the gaa. Onoa out of tha araa, obtain an anargancy gaa naak and return to tha araa and correct tha trouble. A vietin of chlorlna gaa funaa nuat ba ranovad aa quickly aa poaalbla fron tha gaaaoua area. Place patient on hla back with head and back alavatad. Milk nay ba uaad In aild caeca aa a relief fron throat irritation. If tha patlaat haa atoppad breathing, atart artificial roaplratlon lanadlataly. b. Biphenyl Biphenyl la a flaambla aatarlal which will burn. Burning ahould not ba dene In tha praaenca of Biphenyl or Biphenyl vapora. Tha uniting point la 68.7C., and tha auto Ignition tawparatwra la 258C. Inhalation of Blphanyl funaa la not raconnendad, aInca It can cauao a drugged affect on tha peraon. c. Santowax B Saptowax B la a flanaabla aatarlal which will burn. It la relatively non-toxic to huaan balnga. However, the vapora of Santowax B are Irritating to tha naeona ' nenbranaa and bronlchlal tract. Pro longed breathing of tha vapora ahould ba avoided. Tha naltlng point la 140C. MOWS 049865 APraroix j 6. (Continued) d. Santowax C a. Ferric Chloride f. Attapulgua Barth f. Hydrated Line h. Cruda Aroelore 1. Hydrogen Chlorina Oaa ). Still Bottoma or Baaldua Cm and Action to Fraront 7, Sana aa Santowax B, alaea It la tha cruda aatarlal prior to dlatlllatloa. Barrie Chloride la a black-brown eolld. ' It eauaea only lightly lrrltatlag affeeta oa tha kla or aueoua membranea. ifhaa haatad It will deconpoee and ralaaae toxla fume of Chlorine. It will react with water to produce toxic and corroalwa BC1 fumaa. Ihla material la a dried earth. Bo danger In handling. Waah off with water to claan. Bo particular haaard la handling thia material. The duet la lrrltatlag to the ayaa and akin, and ehould be waked off with water. Cruda Aroelora are hot, aInca all are handled In ateam traced or jaekated llano. They can aaally eauaa therwl buna la contact with tha ekla. Prior to air blowing, tha aatarlal haa BC1 fumaa entrained la It which are lrrltatlag to tha akin or aueoua nambranaa. Thla la a corroalwa gaa which la toxic. It la Irritating to tha aueoua nambranaa, to tha ayaa, and to tha reaplratory tract. It will react with wtar to form Hydro chloric Add. Buawa from atlll bottone are toxic. They aro extremely Irritating to tha wcona nambranaa, to the ayaa, and reaplratory tract. MONS 049806 MQNS 0<9867 STANDARD MANUFACTURING PROCESS FOB AROCLORS AFUMPIX K BACKCROPHP INFORMAIICM History of th Process In Monsanto In ths yssrs 1927 - 1928, the Swann Chaaileal Company developed a procaaa for making diphenyl, but aa tha expected demand for It did not contlnua, othar outlata wars aought for tha dlphanyl. Aroelora vara producad In tha laboratory In 1928, and aa thay showad good alactrlcal propartlas, flra raslstanca, and ganoral lnortnaas, tha Canaral Ilactrie Conpany bacana Interested, and davalopad tha uaa of Aroelora In transfonaara and capaeltora. Biphenyl production began on Fabruary 28, 1928; Aroelor production (3,000 lbs/day) startad on Decenber 16, 1928. In 1935 Monsanto acquired tha Swann Conpany, so gaining access to their Aroelor patents. As tha demand for Aroelora lneraasad, additional production equipment was Installed, located at tha Monsanto Illinois factory (than Plant "B" and now called tha Kruonrlch Plant). This equipment cans on stream In September 1936. The Krummrlch plant site was chosen partly because of tha availa bility of chlorine there, but whan chlorine eonsuuptlon overtook tha production, and chlorine had to be purchased, proximity to tha dlphanyl production at Anniston had more weight, and additional capacity, largely designed on the plant "B" nodal, was Installed at Anniston in 1941. By 1946 both plants had doubled their capacity, to give a total production capacity approaching 2 million pounds a month. About 1954, chlorine cells were Installed at Anniston. Tha Newport plant was designed, mainly on Krunmrlch plant Inton ation, but to a laaa extant on Anniston Information, under Newport Project No. 12 of the London Central Inglnaarlng Department. Chlorination started at Newport In June 1951, Mr. Jack Clegorn from Anniston spending seme time at Newport to assist In starting the diphenyl and Aroelor plants thare. Tha first production of Pyranol by MCC was In 1936, whan Pyranol 1488 was made for the General Blactrle Conpany, the blending being done at first In rail tanks. Pyranol 1495 was made In July 1938. Batch chlorinated Aroelora were made until November 1957 whan continuous chlorlnatsd Aroelora ware first made In plant equipment. HONS 049868 Appandlx K - Background Information Arodora 2 Savaral teat run* war* made and aold to cuatomera for evaluation. On February 14, 1961, contlnuoua chlorinated Aroclor 1242 waa made on a full time baaia. Today Aroclor la made by both batch and contlnuoua chlorination of Biphenyl and/or Santomax. In May 196S an roclor axpanaion wa* completed to bing the capacity to 58 M pound* par year which Includee 10 M pounda par year of Solid Aroclora. Aroclor Uaaa Monaanto Aroclora are uaad "a* la" or in special formulation* for tha liquid coolant-lnaulatlon fluid* in tranafornar* and capaci tors. In capacitors, they provide for power factor correction in alactrle utility transmission Unas. In fixed paper capacitor*, Aroclora ar* tha dielectric substance. That* capacitor* ars used in hoam appliance* such as air conditioners, furnace*, washers, and drier*, in alactrle motors, and for ballast in fluorescent fixture*. General Electric, Haatlnghouse, and other producers of alactrle capacitor* us* Monaanto Aroclor* in special formulations for tha dielectric aubatanc*. Other important applications of both Liquid and Solid Aroclora la tha electrical field ar* in wire and cable coatings and a* lmpragnanta for cotton and asbestos braldad insulation. In addition, they ar* excellent dielectric sealants and are used to clot* tha pora* of carbon resistors and to seal electrical bushing* and terminal*. Aroclora ar* outstanding for uaa as tha hast transfer liquids in indirect heating systems. Aroclor systems can transfer oloaaly controllable, uniform hast to chemical process vassal*, food cookers, potato chip and frlto fryers, drying ovens, to hast corrugating rolls, crimping presses, and calendars in material processing, to hast treating metals such as Titanium and Vanadium, and to efficiently indirect hast distillation equipment. MQNS 049869 APPENDIX X - Background Information Aroclort 3. It la Interacting to nota that aa recently aa 1961 only two nethode of delivering prooeee heat wera known. Today non-pressurised, high temperature, flra raalatant haat tcanafer eyetame bated oa Honeanto'a Aroclor Liquids overcome practically all tha deflclenclee and dravbacka of Dlract-Flrlng and Praaaurlaad Vapor Heating. Praaantly, thera are numerout other uaea for Liquid and golld Aroclort and Aroclort In formulatlont. Only toma of thate utet ara lilted belowt At the actuating medium In bellova controlt, tharmottatt, Industrial temperature control regulatori, and other kinds of automation equipment. Liquid taalant for furnace rooft. Vacuum dlffutlon pump oll-pumpa uted to pull high vacuum for mttallilng pleetlce, dehydrating foods, and madlelnalt. Dust entrapment-uied to coat flbroua glatt air filter pads, matal math, and other matarlalt utad for filtering air and gat atraama. Aa a vapor auppreaaant to lncreaee tha kill Ufa of lnaactlcldea. In waxea-vaxea containing Aroclor ara widely uaad la making dental caetlnge. In tha pradalon catting of aircraft parts, and for catting eoatuma jewelry. In epecialiaed lubricants, adhealvaa, Ink formulation, caulking cosqpoundt, plattice, rubbers, paints, vanishes, and lacquer formulatlont. Haw uaaa for the various Aroclora ara continually being developed. Continuous quality control, coupled with the unusual chamleal and physical characteristics of the Aroclora, hat resulted In wide spread' customer acceptance and a limitlate expansion of uses for than. MONS 069870