Document RJR0nzgkaj8vr74a0r2XzJOVn
Pydraul fact finder
AIR COMPRESSOR LUBRICANTS
Bulletin number IC/FF-2
The Pydraul* Air Compressor Feet Finder ... is designed to make the many facts about Pydraul* fire resistant lubricants for air compressors--Pydraul 306, Pydraul 90E and Pydraul 115E--easy to find. These safety lubricants for air compressors were specially developed to offer you: Safety from Fire and Explosion Pydraul reduces combustible mists and minimizes carbonaceous residues--greatly reducing the threat of compressor fires and explosions. Lower Maintenance Costs Pydraul reduces deposits on exhaust valves, In cool ers and in piping. You save the costs ol compressor downtime and cleaning. Many compressor users find these savings alone justify using Pydraul lubricants.
*0A|S 0 78493
pyprauL
COMPRESSOR lUBRiCANIS BY
Pydraul fact finder
HOW COMPRESSOR FIRES & EXPLOSIONS OCCUR
Every theory about the mechanisms of compressor fires end explosions hold one Idea in common: petroleum oils are directly involved.
Petroleum Oil Mists A Films
Mist and accumulated films from petroleum oil In compressor systems can, under a variety of con ditions. break down Into combustible gases and carbonaceous residues that can ignite and pro duce an explosion, a receiver fire--or both. The U. 8. Bureau of Mines' found that carbon deposits in air compressors lubricated with petroleum oil form a Mcarbon-oxygen complex." Oxidation forms this complex, and accelerated by heat, this oxida tion process can lead to an explosion.
The Shortcomings of Safety Devices
Safety devices do not completely eliminate fire and explosion possibilities. A study on "The Mech anism of Explosions In Starting Air Lines,"3 based on an exhaustive survey of compressor operations at 53 companies, reports that a stuck or leaking air check valve permits the engine being started to pack the section of line between the check and air timing valve with an explosive "oil residue-air" mixture. A pressure wave will force this mixture upstream into the main air line--and coupling this with good flame propagation In the power cylin der, the condition Is laid for explosion in the pipe system.
Air line explosions and fires may even occur with out the engine being started or before the Ignition
is turned on. Carbon and rust particles in a "hot" air line, due to operating an overheated compres sor too long--hardly an improbable conditioncan become saturated with oil. and with the flow of starting air, can cause these oil-saturated parti cles to ffame.
Explosion Teals at 1300 P8I
The Walter Kkfde Company, makers ol fire extin guishing equipment, warns In a study3 that users of high pressure air should guard against intro ducing a shock wave Into high pressure lines by suddenly opening a plug cock in air compressor systems using petroleum oil. This report showed that in a 1-inch diameter tube, the inside wells filmed with oil, a sudden admission of air at pres sures above 1300 psi caused combustion.
How can you eliminate the conditions that cause fires and explosions in air compressors? Eliminate the source of carbon deposits, the basic cause of most air compressor disasters--petroleum oil.
Substitute fire- and explosion-resistant Pydraul.
1. "The Carbon-Oxygen Complex as a Possible Initiator of Explosions and Formation of Carbon Monoxide In Compressed Air Systems," by Busch, Berger, end Schrenk. Bureau of Mines paper R.1,4465, June 1949.
2. "The Mechanism of Explosions in Starting Air Lines." by Ridgway. Robert S., Petroleum Refiner, June 1958
3. "Oil Combustion Phenomena in High Pressure Air Systems," M W VVefbel. Wetter Kkfde A Co , Me., Report R-831, copyright 1952.
45
07S4S4
Table 1
PHYSICAL PROPERTIES
Appearance Spec. Gravity 25V25*C. Neutralization Number (Acidity) (mg KOH/gm) max. Moisture (max.) VISCOSITY Centistokes @ 100'f.
Centistokes <3 210*F.
Saybolts (ti 100*F. 210*F.
"Absolute Saybolts" @ 100*F. (SSU x Density) 210*F. Pour Point Compressibility x 10-* sq. in./lb. Maximum Exit Air Temperature Boiling Point *F. at 760 mm Hg. Coefficient of Thermal Expansion per aF. Specific Neat (BTU/fc. *FJ ($ 77`FJ Thermal Conductivity BTU/hr./lt./*F. Bulk Modulus (Room temp. 10004000 psi) Solubility in water
PY0RAUI* 301
Clear Blue Liquid
1 150-1.170
0.15
0.10%
PYORAUL DC
Clear Blue Liquid
1145-1165
0.15
0.10%
PYDRAUL UK
Clear Biue Liquid
1.145-1.165
0.15
0.10%
30-34 4.6-5.0 150 SSU 42 SSU 173 SSU 47 SSU *--15*F.
2.56 350'F, 725*F. 0.00035
0.36 0.0737 390.000 Negligible
85-95 7.7-8.1 415 SSU 52 SSU 473 SSU 57 SSU +10'F.
2.53 350'F. 805*F. 0.00035 0.38 0.0723 396,000 Negligible
115-125 89-9.3 565 SSU 56 SSU 695 SSU 61 SSU + 10*F.
2.52 350'F. 820'f 0.00035 0.38 0.0721 397,000 Nagligibla
Tibli 2--Vapor Pressure
Temperature
'C. *F.
0 32 10 50 20 68 40 104 60 140 80 176 100 212 150 302 200 392
Vapor Pressure mm Hg
PYDRAUL 30E
PYDRAUL 90E
PYDRAUL 115E
5.0 x 10 * 1.6 x 10* 4.5 x 10 * 3.1 x 10* 1.4 x 10 * 5.6 x 10 * 2.0 x 10
0.3 2.2
2.4 x 10 * 8.0x10* 2.4 x 10 * 1.9 x 10 * 9.2 x 10 * 4.3 x 10 3 1.6 x lO '
0.25 2.0
1.0 x 10 * 3.8 x 10 * 1.1 x 10* 1.0 x 10 * 5.1 x 10* 2.6 x 10 3 1.0 x 10 3
0.2 1.8
Vapor Density= 11.2 compared to value for air of one (1).
CompaMbMty With Metals Pydraul air compressor lubricants are compati ble with all construction metals IncludinQ alumi num. Aluminum load bearing surfaces should be hard`anodized tor maximum aqulpment Ufa.
HCNS 078*95
Pydraul fact finder
FIRE RESISTANCE
Pydraul ffrresistant fluids and lubricants have worked In industry since 1961, providing many mil lions of machine hours of fire-free operation. Never since their introduction in 1954 has any Pydraul fireresistant compressor lubricant caused a compressor fire or explosion.
FIRE-RESISTANCE TESTS OF PYDRAUL 90E,
PYDRAUL eOE AND PYDRAUL USE
TEST
High Pressure 8pray Test AMS31SOC and Federal Test Method St. 7ft. Test fluid sprayed st 1000 pel through orifice, pass ing through Sams of oxyacoly tena torch. 6000F.
RESULTS
Does not flash or ignite up to 3% feet from orifice.
Atomized Spray Teat (proce* dura used by Factory Mutual Engineering Division). Teat fluid healed lo 140F. sprayed at 1000 psi trom atomized cone type nozzle. A torch la pasasd through this spray 2 feet and 2 lo 6 inches (torn ihe orifice.
Local burning by torch at S inches and 2 last from orifice. Flames self-exitngulah Imme diately when torch removed.
Hot Manifofd Test (Federal Tost Method Sid. 791). Test fluid dripped on lube et 1300F.
Does not flash or burn.
Molten Metal Ignition Teat. Test fluid exposed to the surface of eiumlnum alloy at 1200F., to teat tor spontaneous ignition.
Does not ignite.
Figure 1--Typical Viscosities ---- FYMMjftOE -- PYMAUL 90f -- PYMAUL 115C
RONS 076496
CONVERTING TO PYDRAUL IS EASY
First, simply drain the petroleum oil and wipe the crankcase or lubricator.
Thoroughly dean the exhaust valves and Interstage equipment before filling the crankcase or lubricator with Pydraul. Pydraul will loosen carbonaceous de posits, varnishes and sludge. Unless these loosened deposits are cleaned from the system, they could ciog pipelines and components, requiring additional downtime and production loss. Once the valves have been thoroughly cleaned of potentially dangerous carbon deposits, Pydraul lubricants will keep them C)Ban_and let compressors run longer between maintenance shutdowns.
STANDARD CHECK FOR COMPRESSORS--Plastic separator bowls. Not all plastic separator bowls are suitable for Pydraul service. Certain plastics are "crazed" or softened when exposed to Pydraul. Bowls made of glass, brass, steel, and these plastics--polycarbon ate, polyethylene, or nylon--are recommended for use with Pydraul. If you have a question regarding the resistance ol a particular plastic, Monsanto will be happy to advise you.
Diaphragm valves. Pydraul lubricants have a soften ing effect on neoprene and buna N rubber dia phragms normally used for petroleum oil service. These diaphragms should be replaced with butyl rubber, EPR (ethylene propylene rubber), fluoroelaatomer, silicone or other compatible elastomer ma terials resistant to Pydraul fluids. Diaphragm sheeting Is available from normal sources of supply.
All diaphragms In unloading valves or downstream control valves should be replaced at the time of changeover. Diaphragms in valving downstream from separator systems or drying systems need no! be replaced a! changeover time, but should be changed on a preventative maintenance schedule as soon as practicable after operation on Pydraul is begun.
For air compressors supplying air for instrumentation functions, mist eliminator systems are recommended to remove lubricant mists and moisture from air streams. A Monsanto development, a Brink* mist eliminator is a particularly effective system, available from Monsanto in a series of low-cost mist eliminator
systems to operate at all capacities. For information on a Brink series suitable lor your compressor sys tem, write tor
Monsanto Enviro-Chem Systems, Inc. 800 North Lindbergh Btvd. St. Louis, Mo. 63166 Telephone: (314) 694-2386
(Joseph A. Brink)
SPECIAL CHECK FOR SPLASH-LUBRICATED COMPRESSORS
Crankcase paint Pydraul air compressor lubricants will soften and loosen some paints from crankcsse Interiors. These paint particles could block the lubri cant passages. For this reason, it is a good practice to remove paint from crankcase interiors before Pydraul is added to the system. Standard paint removers are adequate for removing Ibis paint.
SPECIAL CHECK FOR FORCE-FEEO LUBRICATORS
Sight-glass IHild. If a separate force-feed lubricator of the type normally filled with water and glycerine is used, one of two changes is necessary: either re place the sight-glass fluid with one heavier than Pydraul or insert a metal bobber in the sight-glass. Pydraul fluids are heavier than water or glycerine and will not rise through these standard sight-glass liquids. Fluorochemical 101, a clear liquid supplied by the Minnesota Mining and Manufacturing Com pany, has a higher density than Pydraul and is a completely satisfactory replacement.
Metal bobbers. The alternate to using Fluorochemical 101 is to modify the sight-glass lubricator by inserting a simple metal bobber. The bobber is installed by draining the sight-glass liquid, removing the guide wire and inserting the bobber. Operation of the lubri cator is then indicated by movement ol the bobber with each stroke of the pump plunger Instead of counting the drops as with guide wires. Bobbers are available for either McCord, Manzeil, or Lincoln Engi neering lubricators. Modification of the MadisonKipp lubricator requires replacement of the entire sight-glass.
Vacuum-sight lubricators. Vacuum-sight lubricators require no modification for Pydraul usage.
HGNS 070497
Pydraulfact finder
LUBRICATION DATA
MIXING COMPATIBILITY
"
DROP SIZE
Drop size of a lubricant it important to determine an adequata lubricant Injection rate to insure proper compressor lubrication. The rate of lubrication Is controlled by noting the drops per unit of time.
The drop size for the fluids tabulated below were determined by noting the number of drops formed at room temperature (75F.) on a 1 mm f.D. by 3W mm b.D. glass tip. (Larger or smaller drops will result If different sized tips are used.)
FfuM
Medium weight petroleum oil Pydraul 90E
Drops per cubic centfcmHsf
33 39
When Installing new equipment, It is best to start with an Increased lubricant febd rate and reduce this rate by successive increments. Inspection of cylinder walls and valves will indicate the proper degree of wetting.
Pydraul 30E, Pydraul 90E and Pydraul 115E are com pletely miscible in ell proportions with competitive synthetic phosphate ester lubricants.
Tito** 3 Fsftx Wear Test
Pydrtu0 JOE Pydrmrf 90E Pydraul 1JBE
WT. LOSS. PIN (me.) 0.1 0.7 1.0
WT. LOSS. SLOCKS (mg.)
0.2
1.0
0.3
TsMs 4
Shell Four-Ball Wear
(I67'F., I hour, 630 rpm., mm tear diameter}
STEEL ON STEEL
PYORAUl SOE
PYDftAUL eoe
4 l 0.47
0.28
10 kg 40 NS
0.50 0.04
0.32 0.54
STEEL ON SaONZE
10 kg
0.46
0-35
40 kg
0.97
0.65
PYDRAUL USE 0.29 0.39 0.56
0.45 0.66
HONS 070498
USES BY MAJOR MANUFACTURERS
TOXICITY AND SAFE HANDLING
Nw air compressors of most typos and sizes pro duced by major compressor manufacturers can be manufactured for lubrication with Pydraul. The manu facturers listed (below) have manufactured compres sors equipped for Pydraul, upon specification of the buyer, for over ten years. Many compressors have operated on Pydraul lubricants continually with ex haust air temperatures of 350F. Pydraul is also used to lubricate cylinders in compressors operating at pressures over 4500 psig.
American Messer Corporation
Atlas Copco
Bury Compressor Company
Acute animal studies indicate that the Pydraul E Series Fluids can be classed as practically non-toxic when considered as an industrial fluid. They are non-irritating when the skin Is exposed to the fluid. However, this product should not contact or In any way contaminate food, animal feed, food products, food packaging materials, pharmaceuticals or any Items which may directly or indirectly be ultimately Ingested by humans. Any contact may contaminate these Items to the extent that their destruction may be required.
Due to their low order of toxicity, the Pydraul E Series require no special handling precautions. However, as in handling any chemical, good hygienic procedures should be followed. In case of skin contact, wash off with soap and water. In the case of eye contact, flush with copious amounts of water.
While Pydraul E Series (Pydraul C Series, also AC Series, Santosafe W/G) fluids pose no serious problems with respect to the environment, as a concerned supplier to Industry, Monsanto urges the user to maintain a tight system, to correct leakage promptly and to exercise care in the handling and disposal ol this and all other such products.
Carrier Corporation
Chicago Pneumatic Tool Company
Clark Brothers Company, division of Dresser Industries
Cooper-Bessamer Corporation
DeLaval Steam Turbina Company
Oardner-Denver Company
bigeraolt-Rand Company Joy Manufacturing Company
Kinney Manufacturing, division of The New York Air Brake Company
Norwalk Company, Incorporated
Schramm, Incorporated Worthington Corporation
MCNS 078*99
CUSTOMER SERVICE CENTERS
AKRON. OHIO 44313
260 Springtide Drive Montrote Development Perk Tal (216)666-4111
ATLANTA, GEORGIA 30339
320 Interstate North Parkway Suita 600 Tot. (404)432-7111
I
f
BOSTON, MASSACHUSETTS 02149
Evaratt Statbn Tat. (617) 367-6010
CHICAGO. ILLINOIS
3168 Dog Plainer Ave. Dog Plainer. IPinei* 60018 Tot. (312) 296-6888
CINCINNATI, OHIO 45236
8041 Hoibrook Pood 11. (613) 984-1100
DETROIT, MICHIGAN
600 Northland Towart Wggt Southfield. Michigan 48076 Tot. (313) 367-0910
HOUSTON. TEXAS 77027
1301 Port Oak Towar 6051 Wetthaknar Road Tat. (713) 821-9660
LOS ANGELES. CALIFORNIA
1401 Dove Sheet Newport Baacb, CaUfornia 92660 Tat. (714) 833-9160
NEW YORK, NEW YORK 10036
1114 Avenue of the Americas Tat. (212) 784-5000
ST. LOUIS, MISSOURI 63166
800 N. Lindbergh Btvd. Tal. (314) $94-1000
SAN FRANCISCO BAY AREA
2710 Lafayette Santa Clara. California 95052 Tal. (408) 243-0414
I Monsanto
SEATTLE. WASHINGTON 98121
2112 Third Avenue Tal (206) 822-4203
WILMINGTON, DELAWARE 19810 Suka 204. Bancroft Bldg.
I 3411 Sdvaraide Road Tal. (302) 478-4600
i i Monsanto Industrial Chemicals Co.
A Unit of Monsanto Company 800 N. Lindbergh Blvd., St. Louis, Mo. 83106
V
MQNS 076500
llaneo upon contained Information or racommandatlona. and dlidotma all liability lor any rntuttinc lota 01 damage."