Document RJNonbprRvGy9mKGjjLYRR8Qv
Roy T. Gottesman
Executive Director
June 11, 1990
TO: The VI Health, Safety & Environment Committee
RE: VCM Cartridge Filter
Dr. Brian Bennett of ICI Chemicals and Polymers has sent me copies of the slides which he used at last September's Vinyl Chloride Safety Association meeting with reference to the VCM cartridge filter.
He informs me that this is now available through Drager, but that other companies wish to get into this canister market. He anticipates that in the future, the price will drop drastically below the 7 (approximately $12.00) price per unit.
Further, Brian Bennett informs me that ICI has used this canister at their Hillhouse Site in several other areas with a great deal of success and acceptability by the workforce.
In addition to the slide copy, which is enclosed, should you wish
further information on this, please contact Dr. Brian Bennett at
the following address:
Dr. Brian Bennett ICI Chemicals and Polymers Limited
P.O. Box 4, Hillhouse Site Thornton Cleveleys
Blackpool FY 5 4QD, England Telephone - (0253) 861444 Telefax - (0253) 861861
Sincerely yours
RTG/pmb cc: Dr. B. Bennett
M. Scheck
CTL019038
Wayne interchange Plaza II 155 Route 46 West Wayne, NJ 07470 (201) 890-9299
\ t
v - c - iyi . IXiXJ'i'ZVGEISr
WULiTI --OJR.Gi\2ST <AJST X IMAX. CARCINOGEN PROVEN HUXXLAJST CARCINOGEN
CTL019039
THE ULTIMATE REQUIREMENT IS TO HAVE A SAFE SYSTEM OF WORK COUPLED WITH THE NECESSARY ENGINEERING CONTROLS TO PREVENT ANY TOXIC GAS/FUME/DUST EXPOSURE TO ANY PERSON, TOGETHER WITH REGULAR AREA AND PERSONAL MONITORING AND AUDITING OF SYSTEMS.
CTL0I9040
NORMAL WORKING PRACTICES * PERSONAL AND AREA MONITORING IN PROGRESS * SCABA TO BE AVAILABLE
PROCEDURES IN FORCE IN CASE OF PLANT OR SITE EMERGENCIES
CTlO19 041
CURRENTLY MEN ARE NOT WEARING SELF-CONTAINED OR AIR
LINE BREATHING APPARATUS TO DO A 2-MINUTE JOB -
e.g.
RAIL OR SHIP OFF-LOADING
LEAK DETECTOR MAN
CERTAIN FITTER DUTIES
CTL019042
Often unreasonable and impracticable to wear Air-line Breathing Apparatus due to Trailing Leads - e. g., connection or disconnection of VCM Rail/Road Tankers. A Self-Contained Breathing Apparatus weighs at least 40 lbs. and a Leak Detector Man is often unable to wear it due to situations in which he has to work, and also because of the weight, if required to wear the equipment for long periods.
CTL019043
J'
V C M CARTRIDG E FILTER
AIM :
TO PROVIDE A FULL FACE MASK, HSE-APPROVED, DISPOSABLE
CARTRIDGE RESPIRATOR - LIGHTWEIGHT, EASY TO USE FOR
SHORT DURATIONS IN KNOWN LOW CONCENTRATION AREAS OF
WORK.
ALSO TO CONFORM TO THE BASIC REQUIREMENTS AND BE ACCEPTABLE TO THE WEARER
JOB OPERATIONS FOR EXAMPLE :
CONNECTION/DISCONNECTION OF VCM ROAD/RAIL TANKERS
(Cartridge Filter Respirator will not replace any self-contained or Air-line Breathing Apparatus).
CTL019044
A GAS FILTER RESPIRATOR - EITHER CARTRIDGE OR CANISTER MUST NOT BE USED IN :
STILLS TANKS CONFINED SPACES ANY CIRCUMSTANCES WHERE A HIGH CONCENTRATION OF GAS IS LIKELY TO BE PRESENT ATMOSPHERE DEFICIENT IN OXYGEN
CTL019045
NOT RECOMMENDING THAT ANY INDIVIDUAL USES A CARTRIDGE FILTER RESPIRATOR INSTEAD OF SELF-CONTAINED OR AIR LINE BREATHING APPARATUS.
RECOMMEND THAT THE CARTRIDGE FILTER RESPIRATOR IS USED WHERE POTENTIAL EXPOSURE. RATHER THAN PREDICTED EXPOSURE
MAY OCCUR.
(Based on monitoring results showing very few above the O.E.L. / T.L.V.)
CTL019046
VCM CARTRIDGE FILTER
* WEARER ACCEPTABILITY * CONTROLLED USE BY A DESIGNATED OPERATOR ON A DESIGNATED
JOB OPERATION * TO INCLUDE PERSONAL AND AREA MONITORING FOR VCM * DISPOSAL OF CARTRIDGE AFTER A SINGLE SHIFT USE * USED CARTRIDGE FOR DISORPTION TEST
USED CARTRIDGE FOR POSSIBLE RE-GENERATION EVALUATION
CTL01904,7
'V'CIX! CARTRIDGE FILTER
BASIC CONFORMANCE TO
BS 2031
1%
30 MINS
DURATION
ESCAPE USE COVERS
HCL
EEC
Cl2
(Use Cartridge Filter Respirator for Escape Usage, and it must be full face).
CTL019048
ONLY RESPIRATOR WORKING TO A BRITISH OR EUROPEAN STANDARD THE U.S.A. AND EUROPE FILTER RESPIRATORS DO NOT CONFORM TO SET APPROVED STANDARD
CTL019049
VCMCARTRIDGK PROJECT
E Q U IP ME NT
ED U CATI 0 N COMMUNICATIONS
CTL019050
"THE VCM GAS FILTER" is now ready for full industrial use, with the appropriate safe systems in operation, as follows
1) Correctly labelled canister "Vinyl Chloride use only". 2) Training procedures for the wearer. 3) Control of Issue and monitoring. 4) Designated job operation use only. 5) Continue random disorption tests. 6) Correct maintenance and servicing procedures in operation. 7) Correct disposal of contaminated filters. 8) Adequate storage. 9) Documented Records to be kept of all issues and servicing. 10) Clear emphasis that this respirator does not replace
existing use of breathing apparatus.
CTL019051
A GAS FILTER RESPIRATOR - EITHER CARTRIDGE OR CANISTER MUST NOT BE USED IN :
STILLS TANKS CONFINED SPACES ANY CIRCUMSTANCES WHERE A HIGH CONCENTRATION OF GAS IS LIKELY TO BE PRESENT ATMOSPHERE DEFICIENT IN OXYGEN
CTL019052