Document RJLwRmYdddZod5VxLrryQzpyn

HAGER LABORATORIES, INCORPORATED ANALYTICAL SERVICES FOR INDUSTRY REPORT ON SERVICE NUMBER 10808 March 16, 1984 j:hl^ 4S6S2-- 3$$77//?70 To : Analysis: Method: Results: Discussion: D. H. Morman Shell Development Houston, TX The following samples were submitted for analysis: Thirty-seven membrane filter samples and one blar*T< for asbestos count. ASBESTOS (count) The asbestos content of each filter sample was analyzed following NIOSH procedure P&CAM 239. Wedges from each filter were examined at 450 power using polarizing and phase contrast microscopes. Birefringent fibers longer than five (5) microns with a length-to-width ratio of 3:1 or more were counted as asbestos. Data is tabulated in Table 1 and 2 of this report. The OSHA permissible exposure limit (PEL) for asbestos is 2 fibers/cc. ND( ) indicates none of the substance was detected, with a detection limit shown in the parentheses. LT( ) indicates "less than" with a detection limit for the analysis shown in the parentheses. Laboratory data are filed and available upon request. Submitted RNH/nl -Robert N. Hager,)/Jr. Laboratory Direp tor LAM 028205 4725 Paris Street/Denver, Colorado 80239/(303) 371-1441 ABS-047095 SN10808 3/16/84 ASBESTOS COUNT Sample Number 4SC021684-5 4SC021684-6 4SC021684-7 4SC021684-4 4SC021684-3 4SC021684-1 4SC021584-5 4SC021584-3 4SC021584-4 4SC021584-2 4SC021584-1 4SC021684-2 4SC021584-6 4SC021584-7 4SC022884-3 4SC022884-2 4SC022884-1 4SC022984-2 TABLE 1 Total Fibers ND(5100) L T(5100) 8900 LT(5100) 18000 22000 5100 7700 L T(5100) 13000 L T(5100) 110000 29000 5100 44000 110000 37000 63000 Air Volume (liters) 630 780 326 478 820 830 404 720 720 876 880 826 510 506 270 270 262 948 K*\ Q O Air Concentration (fibers/cc) ND(0.009 ) LT(0.007) 0.03 L T(0.02) 0.02 s' 0.01 0.01 LT(0.008) 0.01 LT(0.006) 0.13 0.06 0.01 0.2 0.41 0.1 0.066 LAM 028206 ABS-047096 SN10808 3/16/84 ASBESTOS COUNT Sample Number 4SC022984-1 4SC022984-3 4SC022184-2 4SC022084-1 4SC022184-3 4SC022184-1 4SC022084-6 4SC022084-5 4SC022084-4 4SC022084-2 4SC022 084-3 WIL021584-1 WIL021584-2 WIL021684-1 WIL021684-2 WIL021684-3 WIL021684-4 WIL021684-5 WIL021684-6 TABLE 2 Total Fibers 170000 77000 8900 5100 21000 6400 140000 87000 12000 LT(5100) LT(5100) 8900 7700 ND(5100) ND(5100) LT(5100) 7700 5100 40000 Air Volume (liters) 952 946 530 978 280 280 482 670 494 782 780 404 590 32 32 36 36 193 714 \ oCO o Air Concentration (fibers/cc) 0.18 0.081 0.02 0.005 0.02 0.29 0.13 0.02 LT(0.007) LT(0.007) 0.02 0.01 ND(0.2) ND(0.2) L T ( 0.2 ) 0.2 0.03 0.06 LAM 028207 ABS-047097 ...... > * % LAM 028208 ABS-047098 i JU>Q 1 ^ -r>n^~ }0oo svJLjfc- 3^ 336^**-*^-^) i/ -/ 1 or~s* 5^1- 5^'D^H% . 1\ ^J^-<*DCra uJc^Jo-^- C/J-tLOi 15^ M ^3 m3 ^ ^--9^ 32// r>' ^ 7/ /jV*4/*^) u:u\ /^>sJ2> uyr^hjts^ , . (5* l r~S ) C* fr& "T* C'i 3 o **FTV>| L. 02lI1> Crr\ *- , V\ v^2m^cj^. laj^XT c. ^ ^ ^ UirwvX ^Cc p^A_ c^p Y H-; J2a 3.3 /o.ol p,__ pc^7 6/<2-^) C//<7J CK2 0 c*_pka~''~ \ * ,?*'"ei- firyv. e'l8 /5T3 > 1 "/*1 i-4*. **- *P *-AM 028209 ABS-047099 -r!\ X- 3-iH 3, .-,--7 11 ^w/TU/-Ci ' Zj'/S-/C>cl __ 6^,4 ZJ/LS-f-l <r tuw -V~a -- hX^-ciox ^-OV |1>X- . . _______ ____________ /@ G? - /O.^3- uoi t-c^/C^"O1^ _ ... . .< . . ._ cj J'V--,C^AJrAj->^- .._. _/\-& (Cw-^ __ ________ ____ ;'l// o i .^1. (/ 7-g7 >-,-w3 .x--<. //- <:' ?: (~^ 3 7^- fYuA-i. Ow I'Lj# ^r1- C-vv\, LAM 028210 ABS-047100 I J\ A1:! 6! _ oV\ JY\ Sj A y^&Jbv-is* sv'^huv/vJl j-^i tsKcdjdi G- (j- /Jl-VA-Wx. sfj^ V :.fv.;lwV-e^V. . J 1 A_/v\ /wo"--*- ^ * Uvi'ok tlfAMl C;'^ C\J\M- ----------------- - - - ^ y-^wv^vw---- - - ---C---: iH ^ .oi-0^ / W- s T2^'..... Y/............... . . ^ _ P i<>-oV^_. _.`^'l/ofLX- CLA-A/Wv. <a_^3 ^_y~hJLC^U ____ .^JLx^jl ola.-'A___________ ________ _ ______ __________ -aJL. dlv^-vt-- ^ (A Z 3i) M- (V / ^ [7>-- >tOi-* /L-'dAooj Y'^y a--'. CoiL oVtW-Y 'ititr' 'J~jL3y\ r*-Y /1 ? 5 <fy H 3- |ij/AD.il (.SV - C* O' * C^-o<jX_ fA^lPv /. 5- Y2_pi/ Cl-o Jl^.. LAW 028211 ABS-047101 LAM 028184 ABS-047074 ABS-047075 LAM 028186 ABS-047076 LAM 028188 ABS-047078 m iL CouiMJi y / ? / ABS-047079 SU PER VISIN G CHEM IST W/ / ' l nd = none detected (REPORT LIM IT OF DETECTION) CALCULATED BY LAM 028190 ABS-047081 LAM 028192 ABS-047082 ABS-047083 LAM 028194 ABS-047084 ABS-047085 LAM 028196 ABS-047086 C W Y iifi V A /fV LAM 028198 ABS-047088 ili LAM 028200 ABS-047090 SAMPLED BY (LAST NAME & IN ITIA LS ) ACCO UNTING CODE H h i sy ABS-047093 me LAM 028204 ABS-047094