Document RJGVLwVRE53VB3YZRo5p5n3kn

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS 77 WEST JACKSON BOULEVARD CHICAGO, IL 60604 DATE: SUBJECT: FROM: MAR 1 5 1n1q CLEAN AIR ACT INSPECTION REPORT Tradewater Refrigerant Services, Elk Grove Village, Illinois Charles Hall, Environmental Engineer c_.,, ),h,J,{ AECAB (MN/OH) THRU: Brian Dickens, Section Chief AECAB (MN/OH) TO: File, Tradewater Refrigerant Services, Elk Grove Village, Illinois BASIC INFORMATION Facility Name: Tradewater Refrigerant Services Facility Location: 650 Morse Avenue, Elk Grove Village, Illinois Date of Inspection: 08 March 2019 EPA Inspector(s): 1. Charles Hall, Environmental Engineer 2. Natalie Topinka, Environmental Scientist Other Attendees: 1. Karneron Perry, Process Technician 2. Gabriel Plotkin, Chief Operating Officer by telephone during closing conference 3. Kevin Schwartzenberg, Director of Engineering by telephone during closing conference Purpose of Inspection: chlorofluorocarbon reclaimer Facility Type: chlorofluorocarbon reclaimer Regulations Central to Inspection: 40 C.F.R. Part 82, Subpart F Arrival Time: 08:40 a.m. CST Departure Time: 09:55 a.m. CST 1 of 5 Inspection Type: ISi Unannounced Inspection ISi Announced Inspection OPENING CONFERENCE [gJ Credentials Presented lz:I CBI warning to facility provided The following information was obtained verbally from ATTENDEE(S), unless otherwise noted. Process Description: Tradewater receives refrigerants including R-11, R-12, and R-134A in containers that range in capacity from 12 ounces to 1,000 pounds. The number and type of containers received is verified against the number and type of containers expected. The containers are added to Tradewater's inventory and placed in the appropriate storage area. A technician tests the refrigerants with an analyzer to make a preliminary assessment of the refrigerant type and purity. Refrigerant is filtered to remove particulate matter and moisture (water) and consolidated into larger containers including 1,000-pound cylinders, 10,000-pound bulk tanks, and 35,000-pound ISO tanks. Tradewater samples the refrigerant and has it analyzed by an Air-Conditioning, Heating, and Refrigeration Institute (AHRI) -certified laboratory to determine its purity. Depending on the results of the analysis, Tradewater may further process the refrigerant by distillation, filtration, or use of a desiccant bed. Currently, Tradewater ships the refrigerant in 35,000-pound ISO tanks to a third-party-facility for destruction. In the future, Tradewater may also reclaim refrigerant to AHRI-700 specifications and offer it for sale. TOUR INFORMATION EPA toured the facility: Yes Photos were taken during this inspection. Videos were not taken during this inspection. Field Measurements: were not taken during this inspection. CLOSING CONFERENCE Requested Documents: The inspectors requested: A process flow diagram; and The potential to emit calculations for the Plasma Enhanced Melter 2 of5 Compliance Assistance: The inspectors did not provide any compliance assistance. Concerns: During the closing conference, the inspectors stated that they did not identify any concerns. SIGNATURES Lead Inspector: Section Chief: 3 of5 Appendix A: Log of Photographs Photograph Number RIMG000l.jpg R.I~1G0002.jpg Date and Time 03/22/2019 09:00 a.m. 03/22/20-19 09:02 a.iLYL RIMG0003.jpg RIMG0004.iog RIMG0005.iog RIMG0006. ju!:! RIMG0007.io!:! RIMG0008.jpg 03/22/2019 09:04 a.m. 03/22/2019 09:06 a.m. 03/22/2019 09: 17 a.m. 03/22/2019 09:20 a.m. 03/22/2019 09:20 a.m. 03/22/2019 09:21 a.m. Description Storage area for cylinders J~,arge cyli11der u111oadi11g area~ Rcceivi11g Doc-1c jrt background Analyzer Small cylinder and container unloading rack Waste drum storage area Plasma Enhanced Melter Consolidation cylinders Wet scrubber for Plasma Enhanced Melter 4of5 CONFIDENTIAL BUSINESS INFORMATION SECTION Facility Name: Tradewater Refrigerant Services Facility Location: 650 Morse Avenue, Elk Grove Village, Illinois Date ofinspection: 08 March 2019 Photograph of Plasma Enhanced Melter taken on 03/22/2019 at 09:20 a.m. Photograph of Consolidation cylinders taken on 03/22/2019 at 09:20 a.m. Photograph of Wet scrubber for Plasma Enhanced Melter taken on 03/22/2019 at 09:21 a.m. 5 of5