Document RJGEE1vnvp1br3Qop2VjbgkVV

^Goodrich INTER-ORGANIZATION CORRESPONDENCE TO FROM subject Mike Guyer Scott Johnson FIELD POINT OR DEPT. & BLDG NO FIELD PONT OR DEPT. & BLDG. NO. DATE YOUR LETTER DATE THIS LETTER May 4, 1993 First Quarter 1993 Industrial Hygiene Summary - Geon Plant Henry Plant personnel monitoring results for January through March of 1993 are summarized as follows! I. NOISE (BFG Exposure Limit 50% dose) (OSHA PEL - 100% dose) NOISE EXPOSURE BY AREA AREA Dryer Bldg. (732) Poly Bldg. ( 731) JOB CLASS Bagger Dryer Operator Leaderman NO. OF EXPOSURE MAXIMUM NO. OF MONITORINGS AVERAGE EXPOSURE MONITORINGS >50%/>100% r% DOSE T (% DOSE) 1 1/0 78.4 78.4 6 3/0 44.5 72.7 1 1/0 74.0 74.0 Compounding (741) Relief Operator Mill Operator Laboratory Operator 1 1 3 1/0 0/1 0/0 81.8 195.9 14.6 81.8 195.9 27.8 II . VINYL CHLORIDE (OSHA PEL - 1 ppm, 8- HR TWA) During the first quarter of 1993 there were 63 monitorings completed for vinyl chloride exposure (35 poly/28 dryer). Of the total monitorings, eight exceeded 1 ppm and 50 (79%) were below 0.5 ppm. These exposures are summarized below* VINYL CHLORIDE EXPOSURE BY JOB CLASSIFICATION JOB CLASS HO. OF MONITORINGS NO. AVERAGE ABOVE 1 ddd EXPOSURE (ddidI MAXIMUM EXPOSURE (c Recovery Operator 12 4* 1.20 6.60 Resin Reclaim Operator 2 0 0.31 0.37 Dryer Operator 11 0 0.32 0.83 Paste/LoSope Charge 14 2 0.43 1.60 PVC Bagger 13 0 0.21 0.33 PVC Warehouseman 20 0.13 0.14 Pearl Charge Operator 2 0 0.28 0.32 Poly/Dryer Leaderman 7 2 8.29 56.0 * One exposure of greater than 1 ppm occurred without respirator and a B of I wa held. BFG-4956-E M & O Priming Co.. Hsnry. In. 6I53T nqc 14678 / III. METHANOL (OSHA PEL - 200 ppm, 8-HR TWA) (OSHA STEL - 250 ppm. 15-MIN. TWA) One pearl charge operator was monitored for short-term exposure while pumping polyvic and methanol into a poly. result was 153.O ppm. The IV. TETRAHYDROFURAN (OSHA PEL - 200 ppm. 8-HR TWA) (OSHA STEL ~ 250 ppm. 15-MIN. TWA) One dryer operator was monitored for long-term exposure while cleaning ultrafiltration cabinets. The result was 500.00 ppm. The operator was wearing a respirator. V. NUISANCE DUST (OSHA PEL TOTAL DUST - 15 mg/M3. 8-HR TWA) (OSHA PEL RESPIRABLE DUST * 5 mg/M3. 8-HR TWA) Operators in the Compounding building and Dryer building were monitored for total dust (PVC) and respirable dust (unspecified). Total - PVC Respirable Unspecified JOB CLASS NO. OF MONITORTNGS Dryer Operator Bagger 4 4 Henschel Operator 2 AVERAGE EXPOSURE mo/M3 0.49 0.31 0.76 MAXIMUM EXPOSURE ma/M: 0.89 0.68 0.97 VI. PEL EXCEEDANCE INVESTIGATIONS Vinyl Chloride - On January 27, 1993 a recovery operator received a VCL exposure of 3.2 ppm without a respirator. The recovery operator rinsed blend tanks, had an equipment opening on a compressor and removed strainer basket cleanings from the Poly Building. The operator assisted another operator on a leaking condenser flange gasket while standing near building ventilation system. The cause of the exposure is unknown. Corrective actions may help to determine the cause. Corrective Actions includes A. S&E operator will monitor area while rinsing blend tanks. B. Take area monitoring samples of dispersion strainer cleanings. C. Both of the above jobs will require respirator protection until monitoring results are complete. NOC 14679 VII. MEDICAL SURVEILLANCE SUMMARY Total number of Examinations - 21 Number of Examinations which showedt a. Hearing loss - O Please call me at 9408 if you have any questions on this information. SJYbs/9515 Sco cc: R.D. Moore R.D. Webber W.J. Grudzinski K.W. Prather M.E. Guyer T. Grabenstetter D.L. Piccinelli D. Gleghorn - Cleveland R.J. Grahek - Cleveland S&E Operator (1) PVC Foreman (4) File NGC 14680