Document RD4R5zk5RX16LZVwZqXOk3mk

@ Tiger Brand High Temperature Applications: Conductor Temperature For use in open or conduit general power wiring around ovens, furnaces, tenter frames, boiler rooms, steel mills, on electric ranges, or for ony similar power application where the insula* tion may be subjected to heat, heat and moisture, oil, grease, corrosive fumes or fire hazard. For use as switchboard wiring where an asbestos braid is preferred. This cable can withstand continuous high temperature without deterioration and has sufficient moisture-repelling properties to meet normol moisture conditions due to condensation in conduit in* stallations. If parts of a cir cuit are liable to be sub merged in water for long periods, however, lead sheathed AVL cables (Table EL) should be utilized. U0*C(230'F) Specifications: Copper Conductor-Annealed uncoated Insulation-Asbestos--------------------------Varnish cambric---------------------------------- Outer Covering--Asbestos braid Finish-Black FHM (flame, heat, and moisture-re sistant) compound - -- This product is manufactured and tested in ac cordance with Underwriters' Laboratories require ments and conforms to IPCEA Pub. S-28-357 where applicable. TB1-102 HIGH TEMPERATURE Type AVA Power Cable Table E Single Conductor 600 VOLTS Date Issued: June 1972 Size AWG or MCM 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 ' 350 400 500 6UU 750 1000 Number of Strands 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61 Insulation Thickness Mils Inner Asbestos 10 10 10 10 15 15 15 20 20 20 20 20 25 25 25 25 25 30 30 30 V.C. 30 30 30 30 30 30 30 30 30 30 30 30 40 40 40 40 40 40 40 40 2nd Asbestos 15 15 15 15 20 20 20 30 30 30 30 30 40 40 40 40 40 40 40 40 Asbestos Braid Thickness Mils 40 40 40 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 a Approx. Outer Diameter Inches .26 .28 .31 .35 .40 .45 .51 .58 .62 .67 .72 .78 .88 .93 .98 1.03 1.11 1.20 1.31 1.46 Approx. Net Weight lbs. per 1,000 Ft. 45 55 72 96 141 199 288 369 447 547 666 816 986 1150 1320 1490 1830 2170 2670 3490 Standard Packing 500' Coil 500* Coil 500* Coil 500* Coil 1000* Reel 1000* Reel 1000* Reel 1000* Reel 1000* Reel 1000* Reel 1000* Reel 1000* Reel 500* Reel 500' Reel 500* Reel 500* Reel 500* Reel 500* Reel 500* Reel 500* Reel $ Diemeter subject to +5% tolerance. For ampocities refer to Poge TB1-801. For conduit sizes refer to Page TB1-802. ^ .... ' Cable identification vio Surface Legend showing "U.S.S. Corp. Ttger Brand UL Type AVA (size) 600 Volts Table E" U.S.S. ANO TIGER BRAND ARE REGISTERED TRADEMARKS. PLAINTIFF'S _____ F "1 I ARCHITECTS/EHGINEERS J i ., .j j How to specify this product | I for purchasing purposes: t I "Cable shall be U.S. Steel ] Tiger Brand TBbl02 or approved equal" (g) Tiger Brand High Temperature Applications: For use in open or conduit general power wiring oround ovens, furnaces, tenter frames, boiler rooms, steel mills, on electric ranges, or for any similar power ap plication where the insula tion may be subjected to heat, heat ana moisture, oil, grease, corrosive fumes or fire hazard. For use as switchboard wiring where an asbestos braid is preferred. This cable can withstand continuous high temperature without deterioration and has sufficient moisture-repelling properties to meet normal moisture conditions due to condensation in conduit in stallations. If ports of a cir cuit are liable to be sub merged in water for long periods, however, lead sheathed AVL cobles (Table EL) should be utilized. Conductor Temperature 110*C (230*F) Specifications: Copper Conductor--Annealed uncoated Insulation-Asbestos Varnish cambric-----Outer Covering--Asbestos braid Finish-Black FHM (flome, heat, ond moisture-re sistant) compound--------------------------------------------------This product is manufactured and tested in ac cordance with Underwriters' Laboratories require ments and conforms to IPCEA Pub. $-28-357 where applicable. TB1-102 HIGH TEMPERATURE Type AVA Power Cable Table E Single Conductor 600 VOLTS Date Issued: June 1972 r k. Size AWG or MCM 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000 Number of Strands 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61 Insulation Thickness Mils Inner Asbestos 10 10 10 10 15 15 15 20 20 20 20 20 25 25 25 25 25 30 30 30 V.C. 30 30 30 30 30 30 30 30 30 30 30 30 40 40 40 40 40 40 40 40 2nd Asbestos 15 15 15 15 20 20 20 30 30 30 30 30 40 40 40 40 40 40 40 40 Asbestos Braid Thickness Mils 40 40 40 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 <r Approx. Outer Diameter Inches .26 .28 .31 .35 .40 .45 .51 .58 .62 .67 .72 .78 .88 .93 .98 1.03 i.n 1.20 1.31 1.46 Approx. Net Weight lbs. per 1,000 Ft. 45 55 72 96 141 199 288 369 447 547 666 816 986 1150 1320 1490 1830 2170 2670 3490 Standard Packing 500' Coil 500' Coil 500' Coil 500' Coil 1000'Reel 1000' Reel 1000' Reel 1000' Reel 1000' Reel 1000' Reel 1000' Reel 1000' Reel 500' Reel 500'Reel 500' Reel 500' Reel 500' Reel 500' Reel 500'Reel 500' Reel d Diameter subject to + 5?5 tolerance. For ompocities refer to Page TB1-801. For conduit sizes refer to Page TB1-802. Cable identification vie Surface Legend showing "U.S.S. Cerp. Tfger Brand UL Type AYA (size) 600 Volts Table E" U.S.S. ANO TIGER BRANO ARE REGISTERED TRADEMARKS. PLAINTIFF'S ; ; EXHIBIT l---------------------------------------ARCHITECTS/ENGINEERS How to specify this product for purchasing purposes: "Cob/e shall be U.S. Steel Tiger Brand TBl-102 t_ or approved equal" J