Document RD4R5zk5RX16LZVwZqXOk3mk
@ Tiger Brand High Temperature
Applications:
Conductor Temperature
For use in open or conduit general power wiring around ovens, furnaces, tenter frames, boiler rooms, steel mills, on electric ranges, or for ony similar power application where the insula* tion may be subjected to heat, heat and moisture, oil, grease, corrosive fumes or fire hazard.
For use as switchboard wiring where an asbestos braid is preferred.
This cable can withstand continuous high temperature without deterioration and has sufficient moisture-repelling properties to meet normol moisture conditions due to condensation in conduit in* stallations. If parts of a cir cuit are liable to be sub merged in water for long periods, however, lead sheathed AVL cables (Table EL) should be utilized.
U0*C(230'F)
Specifications:
Copper Conductor-Annealed uncoated
Insulation-Asbestos--------------------------Varnish cambric----------------------------------
Outer Covering--Asbestos braid
Finish-Black FHM (flame, heat, and moisture-re
sistant) compound
-
--
This product is manufactured and tested in ac cordance with Underwriters' Laboratories require ments and conforms to IPCEA Pub. S-28-357 where applicable.
TB1-102 HIGH TEMPERATURE
Type AVA Power Cable
Table E
Single Conductor
600 VOLTS
Date Issued: June 1972
Size AWG
or MCM
14 12 10 8 6 4 2
1 1/0 2/0 3/0 4/0 250 300 ' 350 400 500
6UU
750 1000
Number of
Strands
7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61
Insulation Thickness Mils
Inner Asbestos
10 10 10 10 15 15 15 20 20 20 20 20 25 25 25 25 25 30 30 30
V.C.
30 30 30 30 30 30 30 30 30 30 30 30 40 40 40 40 40 40 40 40
2nd Asbestos
15 15 15 15 20 20 20 30 30 30 30 30 40 40 40 40 40 40 40 40
Asbestos Braid
Thickness
Mils
40 40 40 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45
a Approx.
Outer Diameter
Inches
.26 .28 .31 .35 .40 .45 .51 .58 .62 .67 .72 .78 .88 .93 .98 1.03 1.11 1.20 1.31 1.46
Approx. Net
Weight lbs. per 1,000 Ft.
45 55 72 96 141 199 288 369 447 547 666 816 986 1150 1320 1490 1830 2170 2670 3490
Standard Packing
500' Coil 500* Coil 500* Coil 500* Coil 1000* Reel 1000* Reel 1000* Reel 1000* Reel 1000* Reel 1000* Reel 1000* Reel 1000* Reel 500* Reel 500' Reel 500* Reel 500* Reel 500* Reel 500* Reel 500* Reel 500* Reel
$ Diemeter subject to +5% tolerance. For ampocities refer to Poge TB1-801.
For conduit sizes refer to Page TB1-802. ^ .... ' Cable identification vio Surface Legend showing "U.S.S. Corp. Ttger Brand UL Type AVA (size) 600 Volts Table E"
U.S.S. ANO TIGER BRAND ARE REGISTERED TRADEMARKS.
PLAINTIFF'S
_____
F "1
I ARCHITECTS/EHGINEERS
J
i
.,
.j
j How to specify this product |
I for purchasing purposes:
t
I "Cable shall be U.S. Steel ] Tiger Brand TBbl02
or approved equal"
(g) Tiger Brand High Temperature
Applications:
For use in open or conduit general power wiring oround ovens, furnaces, tenter frames, boiler rooms, steel mills, on electric ranges, or for any similar power ap plication where the insula tion may be subjected to heat, heat ana moisture, oil, grease, corrosive fumes or fire hazard.
For use as switchboard wiring where an asbestos braid is preferred.
This cable can withstand continuous high temperature without deterioration and has sufficient moisture-repelling properties to meet normal moisture conditions due to condensation in conduit in stallations. If ports of a cir cuit are liable to be sub merged in water for long periods, however, lead sheathed AVL cobles (Table EL) should be utilized.
Conductor Temperature
110*C (230*F)
Specifications:
Copper Conductor--Annealed uncoated Insulation-Asbestos Varnish cambric-----Outer Covering--Asbestos braid Finish-Black FHM (flome, heat, ond moisture-re sistant) compound--------------------------------------------------This product is manufactured and tested in ac cordance with Underwriters' Laboratories require ments and conforms to IPCEA Pub. $-28-357 where applicable.
TB1-102 HIGH TEMPERATURE
Type AVA Power Cable
Table E
Single Conductor
600 VOLTS
Date Issued: June 1972
r
k.
Size AWG
or MCM
14
12 10
8
6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000
Number of
Strands
7
7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61
Insulation Thickness Mils
Inner Asbestos
10 10 10 10 15 15 15 20 20 20 20 20 25 25 25 25 25 30 30 30
V.C.
30 30 30 30 30 30 30 30 30 30 30 30 40 40 40 40 40 40 40 40
2nd Asbestos
15 15 15 15 20 20 20 30 30 30 30 30 40 40 40 40 40 40 40 40
Asbestos Braid
Thickness
Mils
40
40 40 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45
<r
Approx. Outer
Diameter
Inches
.26
.28 .31 .35 .40 .45 .51 .58 .62 .67 .72 .78 .88 .93 .98 1.03
i.n
1.20 1.31 1.46
Approx. Net
Weight lbs. per 1,000 Ft.
45 55 72 96 141 199 288 369 447 547 666 816 986 1150 1320 1490 1830 2170 2670 3490
Standard Packing
500' Coil 500' Coil 500' Coil 500' Coil 1000'Reel 1000' Reel 1000' Reel 1000' Reel 1000' Reel 1000' Reel 1000' Reel 1000' Reel 500' Reel 500'Reel 500' Reel 500' Reel 500' Reel 500' Reel 500'Reel 500' Reel
d Diameter subject to + 5?5 tolerance. For ompocities refer to Page TB1-801. For conduit sizes refer to Page TB1-802.
Cable identification vie Surface Legend showing "U.S.S. Cerp. Tfger Brand UL Type AYA (size) 600 Volts Table E"
U.S.S. ANO TIGER BRANO ARE REGISTERED TRADEMARKS.
PLAINTIFF'S ; ; EXHIBIT
l---------------------------------------ARCHITECTS/ENGINEERS
How to specify this product for purchasing purposes:
"Cob/e shall be U.S. Steel
Tiger Brand TBl-102
t_ or approved equal"
J