Document RBmYm0brMVab014vwbM8VVaX
COPY
EXHIBITS to the. Vepo^ttton otf E. SCOTT TUCKER, Ph.V takm by the. Platnttfifi on the. 23fid and 24th day4 oft June, 1992.
Caffimmssss !@nn 'Sfrfts
30) MSflC SLILIA'AC, AS n 5, &WJN st., sum: mi
uSffiENVUJLE, 3C zmi l
TEL;
27 [.m n
HARTOLDMON0042930
PLAINTIFF'S EXHIBIT
20<J0
1 0 Now, on your response to Mr. Lorant's question
2 with respect to metabolism 1 wasn't trying to force you
3 yesterday to say that you had to be able to elucido the chair
4 between the metabolism, between the material metabolized and
0
5 the metabolite; but you would agree, wouldn't you, that in
6 order to show metabolism you should be able to find somethin*:
7 which you could call a metabolite, even though you. may not
8 be able to trace it back to the material metabolized? .
9 A I agree.
10 MR. ECKERT; No further questions.
11 JUDGE SWEENEY: You are excused.
12 (Witness excused.)
13 MR. PARK: Could we have a short recess, sir?
14 MR. ECKERT: It's up to Judge Sweeney. I would
15 just as soon move it to Dr. Tucker. We're short of time.
16 Whereupon,
'
17 E. SCOTT TUCKER
18 took the stand as.a witness and, having been first duly
19 sworn, was examined and testified as follows:
20 CROSS-EXAMINATION
21 BY MR. ECKERT:
22 Q Dr. Tucker, as I understood your background,
23 you are an analytical chemist, is that correct?
24 A Yes.
.
Inc.
25 Q Which analytical technique is used for the
TRAN 02852<r HARTOLDMONOQ42931
2C41
measurement of 1'CB's, the quantitative measurement o PCU's?
A The dominant technique that is employed, is
electron capture gas chromatography. There are, however,
other techniques. A
*
Q Now, is that technique more sensitive in the
measurement of higher chlorinated homologs?
A There is a dependence in the sensitivity on the .
degree of chlorination as well as the substitution or the
position of the chlorine in the biphenyl molecule.
Q So that the more chlorines in the molecule, the lower the level at which you would expect you would be able t<
detect residues; is that correct?
.A
That's correct.
'
May 1 add something to that? With the sensitivity
of the electron capture detector there's hardly any problem
in detecting monochloro biphenyls through deccachloro.
There's adequate sensitivity to detect, with this technique,
to detect any isomers including the monochloro biphenyl.
Q Right. But wouldn't the limit of detection for
each isomer change with respect to the number of chlorine
atoms?
'
A Yes, I believe we've established that in your
first question.
Q Do you have a rough idea for comparative purposes
of what the limit of detection would be for a homolog with . TRAN 026525
HARTOLDMON0042932
2842
1 six chlorine atoms or five chlorine atoms as opposed to one
/
2 with two?
3 A When you talk homolog, are you talking an isomer 4 or a homolog?^ 1 think we should define it.
5 Q Well, let me ask you what's a homolog?
6 A A homolog, well, if you're talking about six
7 chlorines you could have -- well, let's talk about three *
8 because I forget how many homologs there are in the six; but
9 if you have, say, two chlorines in a molecule, I think you
10 can have upwards of 12 isomers.
11 Now, all of those 12 isomers constitute a homolog
12 or dichloro biphenyl. So, now, if you're talking about
13 the sensitivity of a homolog, then you may talk about 1 to 12
14 isomers which would, of course, improve your sensitivity in
15 a sense.
16 If you are talking about the detection of a
17 specific isomer then you're into the area where we really
18 don't have any information that indicates specific sensitivi
19 ties of this sort. So, I think very honestly the question
20 should be clarified if you're going to pursue this. V*
21 Q I am glad you did clarify that, and 1 was asking
22 about hpmologs rather than isomers.
'
23 As I understand it, it's much more difficult to
24 identify individual isomers than it is to identify homologs?
Inc.
25 A Yes, but isomers are available and you can
. TRAN 02852b HARTOLDMON0042933
2043
1 measure them and you can run them through an election capture
2 gas chromatograph.
3 Q Well, could you give mo, just for comparative A purposes the limit of detection for 5 chlorine atoms in
5 the homolog as opposed to three?
6 A Okay.
7 I believe -- and with your permission, of- course
8 thai.it might be better to talk about detections in terms
9 of, say, 54 chlorinated biphenyl, which people say is a
10 pentachloro biphenyl, or, say, a 42 percent chlorinated.
11 If you take something like a 4 2 percent chlorinate-^
12 biphenyl and assume unity a.V the detection limit, and you
13 go to something like a 1240, which is 48 percent chlorinated
1A biphenyl, you get, I think, a factor of about 1.542 increase .
15 in sensitivity.
16
If you go to a pentachloro biphenyl, or a 54
1
17 percent chlorinated biphenyl you may get upwards of a factor
18 of 5, and so on. But it is one order of magnitude difference
19 between monochloro in homolog sense, and a deccachloro 20 or, in terms of sensitivity. 21 0 So let me pose you a hypothetical:
22 Assume that we have measured in the environment '
23 a level of very close to the detection limit of 1254; wouldn't
24 it be quite possible that there might be 1242 there in
lr\c.
25 a concentration of roughly one-fifth that which would not
TRAN 028527 HARTOLDMON0042934
2044
1 be picked up by the detection method?
2
-A
Since your question is hypothetical 1 would have
3 to answer yes. However, under actual laboratory conditions
4 when you're operating near your limit of detection there are
5 ways of getting more of the material into the instrument,
6 and I believe that you would sincerely have some indication
7 that there was chlorinated -- lower chlorinated materials .
8 there.
9 So in the real sense, no; hypothetically, yes.
10 Q Well, what is this technique for getting more of
11 the material into the instrument?
12 A Concentrated sample by evaporation, injecting a
13 larger amount, increasing the sensitivity of the detector.
14 Q Well, when you speak of concentrating by evapora
15 tion, do the vapor pressures of the various homologs vary?
16 A You have two questions hore.
17 Q Well, let's speak of the formulation of 1254,
18 1242, 1216, do the vapor pressures in the formulations vary?
19 A Yes, obviously.
20 0 And is it true, asa general rule, that the lower
21 chlorinated formulations have a higher vapor pressure than
22 the higher chlorinated formulations?
TRAN 028528
23 A Yes.
24 Q So that if you were toevaporate a sample
Inc.
25 concentrate you would expect, would you not, to lose more of
HARTOLDMON0042935
2845
1 the lower chlorinated formulations?
2 A If you were not an analytical chemist and did not
3 perform these analyses, you might? that is not the case.
4 0 Well, I don'.t understand your answer.
A 5 A The answer is that, no, under the conditions of
6 evaporation that are applied by mo6t analytical chemists
7 you do not lose the monochloro biphenyls.
.,
8 Q How i6 it done?
9 A You generally blow a stream of nitrogen or air
10 across a hexane containing solution. Now, hexanes' boiling
11 point is so low relative to a monochloro biphenyl that you
12 don't lose it, the ..monochloro biphenyl.
13 Q Now, in the process is salicic acid used as a
14 clean up?
15 A There are some procedures, and I believe it was
16 initiated by the EPA where salicic acid is used as a sdlid
17 absorbant for clean up.
18 Q Is this a procedure that you use?
19 A No. 20 Q Is it a procedure that might widely be used?
21 A It is a procedure that has been used. There are 22 some problems with it, if that's what you're alluding to.
23 0 Well, could you describe the problems?
24 A The problems are that if you are not quite careful
Inc.
25 in terms of the type of solvents and things of that sort
TRAN 028529 HARTOLDMON0042936
I
jrb 11
1 2
3
o4
5
6
7
8
9
10
11
.12
( ; 13 14
15
16
17
18
19
20
21
22 ('
23
24
AceTtdcrol Rtporlvrt, Inc.
25
284 6
that you use, you lose the PCb's from the solvent abso; ant.
The potential exists to lose some of the monochloro biphenyls
or the lower chlorinated biphenyls.
Hovrever, as you go to more polar solvents, when
you load a salicic acid column, you do get these materials,
and most analysts who have been in the business for a while
are aware of this fact, and are very careful to avoid-the
loss of the lower chlorinated materials , in their work-up of
samples.
0 Now, I would like to turn to your paper on
bioaccumulation -- on bacterial degradation, rather.
A What number is that, please?
Q 1'm just trying to find it myself.
It's number --
A No. 21, 1 believe.
Q Right. That'6 correct.
Now, a general question first: In conducting
this test did you make a budget of precisely what happened
to the PCB's that were used in the test?
A Yes. There i6 a budget here in a sense. In other
words you're putting in so much, you're measuring what's
left, and the other disappears; so, therefore, you can accoun
for 100 percent. And that's a budget in a sense.
Q That is a budget in a sense; but do wc know cxactl
what happens to that which disappears?
TRAN O20530
HARTOLDMON0042937
2847
1 A These particular experiments deal with primary
2 biodegradation. I think that's fairly well spelled out in 3 this particular article. In studying the biodegradation of
4 materials this is probably one of the things that you look at *
5 initially, because, after all* if it docs not undergo primary
6 biodegradation, I mean, a minute change, then there isn't
7 much sense in looking at it in any further extensive tests.
8 However, if I will be allowed, I will say that .
9 as time has become more available, and in our laboratory wc
10 have conducted other tests which do show that a number of
u polychlorinated biphenyls undergo ultimate biodegradation.
12 By "ultimate biodegradation," I mean complete
13 mineralization to C02, water, and mineral salts; and they
14 do so at a rate that is equivalent to glucose.
15 0 Which formulations? 16 A These primarily are the lower chlorinated ones.
17 We've been dealing with monochloro biphenyl mixtures. We
18 worked with Aroclor 1221, and we're working our way up the
19 scale. 20
. Now, I will tell you very honestly that as wc get
21 into the more higher chlorinated materials, I do not antici
22 pate complete, ultimate degradation, nor would any micro
23 biologist.
24 Q How have you -- well, you've stated that it
Inc.
25 undergoes complete degradation to C02; how have you identified
. TRAN 028531 HARTOLDMON0042938
2848
1 the; CC>2 as being resulting from the degradation?
2 A Well, there are two techniques that are generally
3 employed to do this type of thing. One is, of course, the
4 radio-label techniques;, the other -- well, actually, there
5 are tiyS^je.
6 One is stable isotope techniques, Carbon-13;
7 one is radio-label techniques, Carbon-14; and another-is just
8 sikmply to use a nutrient pour.! system which has a low .
9 endogenous respiration rate and produces little C02- And thei
10 you add your carbon source, so, therefore, most of the CC>2 i
11 comes from your carbon source. And you can do a budget
12 analysis.
13 The particular test that was employed is the test
14 Thompson and Gunthie. It is a test that is used by the
15 Soap and Detergent Association; it's well-established, and it
16 been around for, I would say, perhaps, maybe 10, 15 years.
17 Q These recent tests thatshow the complete, the 18 ultimate biodegradation, they are not included in the exhibit;
19 you have? 20 A I am sorry, they are not; but I felt they were
21 worthy of mentioning and I did ask your permission.
22 Q Yes.
23 Well, unfortunately, we can't examine you on those
24 because we haven't read them. Are they written up so they
Inc.
25 can bo supplied?
TRAN 028532
HARTOLDMON0042939
jrb 34
' 2 3
( 4 5 6 7 8 9 10 11 12
(" ,3 14 15 16 17 18 19 20 21 22
( 23
24 Ftriefol Reporters, hie.
25
2849
A 1 can provide you with handwritten or maybe
even notebook pages. I will have to check to make sure that
this information can be released; but at this point in time
I see no reason why it cannot be provided to you.
Q Now# in the tests that you did here you vigorously
aerated the sample for a. period of 48 hours; isn't that
correct?
A That's correct.
''
i
Q Now, isn't it possible during that aeration that
some of the PCB's simply evaporated?
A This is a rather obvious possibility, yes.
Q A
Did you use glass containers?
.
%
Excuse me. If you are not going to pursue that,
1 would like to make a comment with your permission?
Q You may clarify your answer.
A Each time this test is run we take the total
effluent, gas effluent, from this unit and scrub thc;n through
scrubbers. The scrubbers are then analyzed to determine
what the volatility losses are. And 1 believe if you look
into the paper in detail the volatility losses are spelled
out.
Q What did you use to scrub the gases?
A The scrubbers were three hexane scrubbers in
series, and what was done was they were analyzed, each one
was analyzed; in other words. No. 1 was analyzed, No. 2 was
TRAN 028533 HARTOLDMON0042940
jrb 15
1 2
3
OA 5
6
7
8
9
10
11
12
13 c
14
15
16
17
16
19
20
21
22 ( 23
2A
Act Fdero) Reporter*. Inc.
25
peso analyzed. No. 3 was analyzed. These scrubbers arc put in
scries to insure that you are not blowing them through,
completely through; and in all cases the last scrubber contai
a very insificant amount, which means we were trapping
any volatilized PCB's.
So volatility losses are not contributing to the
primary biodegradation rates states.
..
Q Were glass vessels used for this experiment?
A ' Yes.
Q
Do PCB's adsorb ontoglass?
A Yes, Q Was this accounted for in any way in ycur results?
A Yes.
There's a little trick in this kind of game,
that when you're dealing with water and soluble materials
j
you obviously run into this problem, and I'in glad you brought
it out.
We operate those units until we achieve what is lm
called a steady state, by which I mean that the surfaces in
the system, for example, the glass and things of this sort,
have actually -- there has been actually enough material
introduced into the system that you read a steady state, i.c.
your active adsorption sites on the glass arc. not -- are fully covered. And so your losses are not due to mechanical
reasons.
TRAN 028534
HARTOLDMON0042941
jrb 16
Cj
1 2 3
4
5 6 7 8 9 10 11 12
(;
13 14 15 16 17 18 19
20
.. 21
22
23
24
Act Ftderol Reporittt, Inc.
25
2851
Q In this experiment, in this particular experiment, you di not identify the metabolite? did you?
A To answer your question, no? there is a reason
that v;e didn't. '*
Q You can explain.
.
A Okay.
'
We manufacture well over -- you see, the scope of my group is a little bit broader than PCB's, although we do
have direct responsibility for the analytical portion of PCB's and the biodegradation and things of this sort. The
company itself manufactures in the thousands of products and we are attempting to develop tests which will tell us about the environmental compatibility of our products.
And so time is of essence. So the first thing to
do is obviously establish that we do get primary
biodegradation. The second thing was to see if we get
ultimate degradation.
.
I currently have one new Ph.D. who is in the
process of attempting to elucidate what some of the melabolit . are, and what the mechanism is for the breakdown of Pen's.
Q Now, after this 48 hours continuous aeration,
what percentage of the PCB's that wore used in the experiment
were degraded? A Well, I would refer you to the paper, unfortunate,
they arc not numbered because the jounal to which it was
TRAN 028535
HARTOLDMON0042942
2852
I
1 submitted said "put it lightly in blue" and that doc.-s not
2 Xerox.
3 But there is a graph in here, and it's about
4 halfway through, and in it we plotted average degradation
5 rate per 48 hour cycle versus the percent chlorine, which,
6 of course, is on a weight-weight basis.
7 Did you find the graph?
8 Q . :, `.Yes,- I have the chart before me.
,
9 Could you describe each of these formulations in
10 terms of the number of chlorine atoms?
11 A Yes, 1 can.
12 The initial one, biphenyl, obviously has zero
13 chlorine atoms.
14 Aroclor 1221 I believe has approximately -- in
15 between, say a mono and a dichloro biphenyl. I thin); it
16 leans a little bit toward the dichloro biphenyl.
17 MCS 1043 is a research compound that was
18 utilized becausse it fit in between and-.will give us a point
19 so we can get a trend. It is sort of a di-tri compound.' .
20 Aroclor 1242 is a trichloro biphenyl. It's
21 considered that. on a percent chlorine weight basis*
27 . ,1`, . .'.'Aroclor 1016 is of course the version that lias
23 the higher molecular rate, more persistent PCB isomers
24 removed, and it would correspond to, say, something less than
Inc.
25 a trichloro biphenyl, since you obviously remove some of the
TRAN 028536
HARTOLDMON0042943
20 S3
1 heavier chlorinated materials.
2 And Aroclor 1254 is a material that has, it's
3 a pentachloro biphenyl, and which has for sometime now ' .
A most closely represented what researchers are finding in the
5 environment. 'However, I hesitate to say that with
6 Aroclor 1254 oven some of the earlier peaks which are
7 tetrachloro biphenyls, and even maybe some pentas, are
8 not found in the environmental samples.
9 Is that an adequate description of the compounds
10 studied?
11
'Q
Yes.
12
13
1A
15 16
17
18
*19
20
21
22
23
2A
, Inc.
25
TRAN 028537
HARTOLDMON0042944
2A ebl
i
2 3
O<
5 6 7 8 9 10 11 12
( 13 14
. 15 16 17
18 19 20
21 22 23 24 Reporlcri. Inc. 25
2854
JUDGE SVfF.ENEY: Ke' 11 take a 15-m.inute recces at
this time, (Rececs.)
JUDGE SWEENEY: Back on the record.
BY MR. ECKERTs
0 Dr. Tucker, I have a couple of questions onbio-
nccuinulation but before we get into that, I have a couple
more questions on your experimental data.
Have you made any attempt to sample environmental
conditions to substantiate or correlate your findings in the
laboratory?
A Yes, in a sense. I think because, again, of the lack of manpower and the scope of the problem we ore dependent
a great deal upon the government and the academic people to
provide this kind of information.
And I think yesterday when you wore referring to
references 2 through 13 in our testimony, there is adequate information that supports the kind of biodegradation data and
the tissue accumulation data that we've been able to generate
with our resources.
.
Q I'd like to turn to Exhibit 12. A What page of our testimony is that referred to.
please? Q
' Well, you've referred to Exhibits 2 through 13
at page 6.
TRAN 028538
HARTOLDMONOQ42945
1
fcb2
1
t2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
; 18
f,,
i
a - 20 4t - 21
22
23
24
Art Tederol Rtporltrt, Inc.
. 25
2 ft 5 5
A Right, page C.
I'd like to refer to it in context to our testi
mony, so I'd like to have it handy.
Exhibit 12?
Q That's right.
Now the statement in the text of the testimony
Js that:
-
"Environmental monitoring programs have .
clearly demonstrated that, with the exception of
direct high-level controllable release near points
of manufacture or use, the PCB's found in our en
vironment are the more highly chlorinated ones,
i.o., those containing predominantly five or more
chlorine atoms per biphenyl molecule."
A Excuse me. I've been attempting to put thoso
references back in order oo that I can find them in a rapid
fashion, so if you would be kind enough, can I have the
question repeated, or the statement or whatever it was? I'm
sorry, I wasn't listening.
Were you reading a statement out of the text hore?
Q I was reading the third paragraph on page 6, the
last sentence of the paragraph, beginning "Environmental
monitoring programs."
A Okay.
q Now with reference specifically to Exhibit 12,
TRAN 028539 HARTOLDMON0042946
28 50
1 to your knowledge arc these eagles v.'hich were sampled eagles
2 which were found near points of manufacture or use?
3 A I have no knowledge of that, no. I do not believe
4 it is stated in the article. However, 1 could be wrong. I'd
5 have to take time to read the article to answer that question,
6 I do not have knowledge of there being near the point source
7 discharge,
8 Q I'd like to have you look at page 254 of that
9 article. Now this is a chart representing the mass spectrum
10 of analysis of tissues of the eagle, is it not?
11 A Yes. This is I think a GC maso spectrum.
12 Q Now on Figure 2, can you identify whr.t the peak
13 is that is labelled M-256?
14 A That's the M/E I believe, as indicated in the
15 figure for the empirical formula
an<^ by thr isotopic
16 abundance pattern, a fragmentation pattern, I would probably
17 say it's a tric-hloro biphenyl. 18 Q So here's an instance where a biphenyl containing
19 less than five chlorine atoms was found in the environment) 20 isn't that correct? 21 A I would like to clarify-- Okay. 22 Yes, to your question. But can I digress for a
23 second and sort of describe what Aroclors are, just very
24 briefly?
Inc.
25 Q If you think it will help explain.
TRAN 0285<t0
HARTOLDMON0042947
2857
1
A
I really do, and after all, we are all here; to
2 try and clear this up.
3
In each of any chlorinated biphenyl product v;hich i i
A is produced by direct chlorination you'll find a little
i
5 bit of Arcelor" 1221, a little bit of Aroclor 12.42, a little 6 bit of Aroclor 1254, a little bit of Aroclor 1200, The
7 point is that they are dominantly one or the other.
e In other words, when you chlorinate a biphenyl 9 directly you get a distribution so the potential exists to
10 have any on of 210 isomers in any of the products.
n I think that's an important point; at least It is
12 to me.
13 0 That is an important point. Doesn't that seem to
\4 indicate that no matter which PCB you are discharging, it
15 will be probably contain some of all the PCB's?
16 A I think this is an obvious point that has been
17 established, yes. 18 Excuse me. Are you going to move on from this 19 article?
i ; i
20 0 If you have some additional explanation of this
21 article, please go ahead.
22 A Okay.
23 I believe this article was included here In support
24 of the statement and I think there is actually a better
Inc.
25 demonstration of the fact that this artielp dofc6 support the
TRAN 028541
HARTOLDMON0042948
2850
Ch5 \
( \i
1 2 3 A 5 6 7 8 9 10 11
12 C 13
1A
15 16
17 18
19 20
21
22 (
23
' 2A
Ace fedeiol Repotteti, Inc.
25
t
conclusion which has been our objection. It can be sc-on if
you look at the graphs on page 253.
These are of course-- I believe these are
eloctron-capture chromatograms of Arocoro 1254 products or
what I prefer to call 54 percent chlorinated biphenyl, and
then that which was isolated from the eagle carcasses.
And I think you'll see that there is a definite
difference in the pattern of peaks between the standard and
those which were isolated from the eagle. So that if you
would look at it going from left to right, in Chromatogram
A you will see1
the early eluding peaks, whioh of course
would be the lower chlorinated materials in that particular
product, and if you go to the Chart B and starting from the
left-hand side again, you'll see that they are highly
attenuated, which indicates that they have been -- they may
have been metabolized and/or excreted, which is a point
which is being made in that particular paragraph.
Q Well, now, you stated that these are attenuated.
Could the attenuation be accounted for by the lower rate at
which the lower chlorinated biphenyls accumulate in tissue?
A I think-- I heard that mentioned yesterday and
I think while there's a difference in, say, the hydrophobic
character of these, I think they are close enough together
that they pretty well accumulate to the point whore you
would see them; so. No. .
TRAN 028542
HARTOLDMON0042949
2859
1 Q Well, you are seeing them here, aren't you, even 2 though they ore attenuated? . 3 A The authors of this paper did see a trichloro
4 biphenyl} yes, sir, but tho fact that the material was not
5 the same as the standard indicates that something has 6 occurred that has altered the pattern.
7 Q Now on Exhibit 37 I believe, the paper by Baxter
8 et al , --"
9 A I hove the exhibit.
10 0 In general is it a fair summary to say that- this
11 paper shows that very little, if any, degradation of hexa-
12 chloro biphenyls occurs?
13 A Yes, that is a fair 'Statement} in the time frame
14 that they used, I might add.
15 Q Now with respect to time frames, these experiments
16 were all done under what might be described as ideal condi
17 tions for bacterial degradation. Isn't that correct?
18 A I think in these particular experiments -- and I
19 would have to review it -- that they used a basal medium,
20 and I'm not so sure that you consider it "ideal" conditions.
21 You might consider it a nutrient pour system,
22 but I would have to review the paper again, however.
23 Q Well, I suppose I should ask the question dif
24 ferently.
Inc.
25 Are you likely to encounter in the environment
. TRAN 0285^3
HARTOLDMON0042950
28C0
1 circumstances as conducive to bacterial degradation as the 2 circumstances induced in these experiments? 3 A I vrould soy that you would find in the environment
A a spectrum of these types of things. In other words, for ^'
5 example, in river water you have a nutrient pour system. In
6 activated sludyo you have a nutrient -- a highly active
7 system. So I'd say you can find these conditions in the
8 environment,
9 Q Now you described the gas recapture or cleanup
10 phase of your old experiments.
11 A You mean * where we checked to make, sure we did
12 have volatility losses?
.
13 Q Yes.
14 A Okay.
-
15 Q Mas the same procedure followed in this experiment?
16 A I would have tocheck.
17 As I recall, Jean Mainprize was the one, the
18 microbiologist involved, and Ron Lidgett. They did check for
19 volatility losses. I think they found they weren't signi
20 ficant. I don't know whether it is in this specific article,
21 but through personal communication with these people, since
22 they are part of our company, of course I have discussed
23 their work extensively with them.
.
24 Q On page 7-- And hold tho Baxter paper, if you
Inc.
25 will, to one side.
TRAN 028544
HARTOLDMON0042951
2 8 G1
obB
(i
1 2 3 A 5 6 7 8 9 10 11 12
( 13 14 15 16 17 18 19 20 21 22
( ' 23
24
Ai'fdnoI Ktputlnt, Inc.
25
A Pago 7, not of--
Q Page 7 of your affidavit.
A All right.
Q A definition ds proposed of polychlorinated bi-
*
phenyls, and it identifies them as those having gas
chromatographic retention times greater than 60, relative
to -- and I don't know how to road that.
.
VThat does this define? Can you describe in lay
terms what this means? A Okay.
First of all it is defined in terms of what I
would say is the recommended EPA methodology which I believe
has come out of the Cincinnati "Laboratory that Jim
Lichtenberg has worked on and that they are i.n the process of
validating.
So the "60" refers to a retention time relative
to a standard compound para para prime DDE, The cut point which is defined by 60 gets down
into-- It starts-- There are some tetrachloro biphenyls
and then of course the ones that are further up, the persistent
ones, the ones that are long lived in the environment.
Is that adequate? ^,
Q I think I understand.
TRAN 0285^5
In other words, this 1b generally those having four
or more chlorine atoms, or is it more than four?
HARTOLDMONOQ42952
20G2
1 A What you said was correct. These etc tho poly 2 chlorinated biphenyls that have generally -- start with 3 tetrachloro biphenyls and then go up.
4 However# just below 60 there might be a minor
*
5 amount of a totrachloro biphenyl or something of that sort,
6 but it is sort of a point where you are cutting at the totra
7 chloro biphenyl and up.
.
.
8 0 Now it's not your contention# is it, that the 9 lower chlorinated biphenyls are not toxic?
10 A Ycu know, it is not my contention that anything is
11 not toxic. You have to be real careful when you talk about
12 toxicity. I'm not a toxicologist and I don't want to be
13 trapped into acting like I am one.
14 Let me explain-- Do you vant to know why we pro
15 posed this definition?
16 Q Yob .
17 A Okay. All right.
18 The definition is proposed bocause we sincerely
19 believe that the predominant problem with polychlorinated
20 biphenyls is the persistence of some of the higher chlorinated
21 ones in the sense that if they persist for exceedingly'long
22 periods of time and can bioaccumulate# then there is the
23 potential possibility that they could achieve# if they
24 continue to be released# that they could achieve a level in
Inc.
25 higher organisms that could have a toxic impact. And this Is
TRAN 028546 HARTOLDMON0042953
eblO
1 2
true c>f anything that accumulates. So v are focusing on this.
2863
3 Now unfortunately in this testimony, it is not
t 4 stated clearly that we are not recommending that wo shovel -*
5 the lower chlorinated biphenyls out into the environment.
6 We are only saying "Let's restrict ourselves to the problem
7 nt hand," and we believe persistence to be the dominant
~
8 problem.
.
9 And you have to look at this document in combina 10 tion of all things that are suggested and not just isolated 11 points. In other words, clean up, restrict and release,
12 restricted use, and things of this sort.
.
13 Q Well, if we had to cut off somewhere, wouldn't 14 we want to cut off at a point which included those which
15 have been found in the environment? For example, the ecodata 16 showed that some of the free chlorine--
17 A Well, first of all, let me back up.
18 You asked me if I could establish that those eagles 19 were collected near a point source discharge. I said No. 20 Can you establish that they were not?
21 Q Well, I think that the burden of proof here, if 27 I can bo so bold, ight to be on those who are putting this
23
24
Ftderol Rtportori. Inc.
25
stuff out.
.
A All right. I may be overstepping my bounds. If
I am, I apologize.
TRAN 028547
HARTOLDMON0042954
28 Ci
obll
I don't know that those eagles -- how close thon .
2 eagles were to a point source diGcharge so therefore, 1 can't 3 have any idea whether or not they could have gotten the
(: '
4 trichloro biphenyls because they were directly exposed to it 5 ot boenuco it clime up through the food chain.
6 Q Well, what about Jensen's papers?
7 A You've only cited one reference to me that shows
8 one example of finding one trichloro biphenyl in an environ
9 mental sample.
10 Q Well, I'll cite another one. How about Jonyen's
11 paper? I believe that's Exhibit 4.
12 A Yes, Exhibit 4.
( 13 14
MR. LORANT: Are you referring to Reference 4? MR. ECKERT: Reference 4 to his exhibit.
15 BY MR. ECKERT:
16 Q Now on page 248 of that paper it states:
17 "We found that the principal BCB components
18 were PCB numbers 7 to 14 but the mussels also con
19 tained the lower numbers."
20 Do you know what lower numbers he's talking about?
21 A Well, as I understand it -- and I've have to go
22 back and look, of course, but Gunther Widmark, who works with
f. 23 Soren Jensen -- He does not work with him now, but they were
24
Ac rdero1 Rcporlin. Inc.
. 25
at the University of Stockholm. They developed a numbering
4%
Bystem for the polychlorinated biphenyls so the numbers 7
TRAN 028548 HARTOLDMON0042955
2DC5
1 through 14 don't necessarily designate 7 -- a biphenyl that 2 contains seven chlorines. 3 And I think if you really read this statement and 4 think about it a little bit, I don't think the implication
* 5 is necessarily there that they are finding the lower chlori 6 nated materials, i.e., monochloroc, dichloros, trichloros. 7 It's juot saying that they are finding the lower numbered 8 peaks as witnesses by their numbering system.
II 9 10 n 12 13 14 15 16 17 18 19 20 21 22 23 24
Inc,
TRAN 028549
HARTOLDMON0042956
285G
2D brb 1 1 2 3
(i 4 5 6 7 8 9 10 11 12
( ' 13 14 15 16 17 18
19 20 - 21 22
( 23
. 24
Act Fadtrol Rtporttn, Inc
25
If you will go further, and if I may read this
"The results suggest that the low PCB
.numbers are metabolized or excreted faster than the
higher numbers, so -there iB an increase of the latter *
as it passes through a. food chain."
This is also so in Jensen's statement,
ft Turning to page 9 of your affidavit, you cles-cribo
a procedure that was done to evaluate the accuracy of these
analytical techniques.
Do you know what the solubility of Aroclor 1242
is?
A. Yes, I do.
In pristine distilled water, you know, solubility
with these types of compounds is kind of a shaky thing, but
in pristine distilled water, I believe, the solubility of
Aroclor 1242 is on the order of 200 parts per billion.
ft How about 1254?
A 1254, I think, drops -- there is a linear relation
ship, incidentally, which is very nice and interesting -- 1
think 1254 is on the order of about 50, but I am coming from
memory now.
ft And 1260? A At 25.
jran 028550
Qi In other words, the distilled water used in these
experiments was spiked with between two times and twenty times
HARTOLDMON0042957
2807
1 the amount which it could solubilize.
2_
Isn't that about right?
.
3 . A. That is correct,
4 Q. Could tho insolubility of tho PCB's account in A
5 part for the differences between tho results obtained by the
6 labs?
7 A. No, it could not, and I will explain why.
8 In the instructions, as I said, the actual whole
9 experimental design which we set up,---.the details are. avail
10 able -- in the instructions to the c :her laboratory that par
11 ticipated in the test, since they were instructed to extract
12 the bottles with hexane.each time and then combine the hexane
13 extracts, then this would effectively take all the insoluble
14 PCB's out of the bottle. ;
15 As you point out, the problem in preparing analytic;
16 standards of this sort with the water-insoluble materials is
17 really a real difficult one. Even if you would put it in
18 below the solubility limit of the Aroclor in:guoetion in the
19 water, in distilled water, some of it would still go out on .
20 the glass, be preferentially adsorbed on the glass..
21
So to answer your question, no, that could5not
.
22 account for the variability that was seen. 23 fit Well, would the hexane extraction take the adsorbed
24 PCB's off the glass?
Inc.
25 A. I am laboratory B, incidentallyI think we did
_
TRAN 028551 HARTOLDMON0042958
2GGP
brb3
1 a pretty good job. We got 93.7 percent, and that's a fair 2 amount in this kind of game. 3 ft Was tho variability different for 1254 or 1260 or A 1242 alone, as opposed to tho mixtures of all three components,
5 sir? 6 A.
Let me refresh my memory here.
7 (Pause.)
' `
8 These limits which are stated, the 95 percent con
9 fidence limits' and. the repeatability limits that, were ob 10 tained through analysis of variance refer to the whole works. 11 These data are all the data. In other \fords, they
12 include the mixtures, too. We did do an additional experiment
(,' 13 which is not mentioned here, in terms of could you or could U you not identify whether you had a 1254, a 1242, and a 1200?
15 There was some variability there. . 16 However; the manner in which those were quantitated 17 is the exact manner which the FDA recommends, and it's probably 18 one of the better ways in terms of doing it when you're 19 dealing with rough mixtures, so that when we had a sample 20 that had all three of the Aroclors in it it was simply broken 21 down into three regions, and throe different standards were 22 employed.
24
fidcrol Rtp0f1#r*( Inc-
25
So I would not think it would contribute -- in othci words, I do not think it would skew the variability.
ft Now, there is a report that van published by Holden
TRAN 028552 HARTOLDMON0042959
20C 9
brb4
1 2 3
O4
5
6
7
8
9
10
11
12
( 13 14
15
16
17
18
19
20
21
22 c
23
24
Act f tdttol fttpoiteu. Inc.
25
which involved a collaborative study of pcb's. Did Monsanto participate in that study?
A. V.'as this the ideal baseline study or the OECD
work? B
The'OECD work, I believe.
A. I do not know whether Monsanto participated in it.
My laboratory did not. We may have in Europe, but I don't
know.
.
.
B Are you familiar with the findings of thes study,
Doctor?
A. I'm familiar with it in a cursory sense, but I am
not familiar with the actual samples or how they were prepared
or how they were distributed or the instructions that were
given and how they should be handled, and things of this sort,
so I'm not prepared to address myself to that at all.
B Well, just addressing yourself to your own results,
your recovery of 93.7 plus or minus 19.2 percenti would you
say that that is a pretty reasonable degree of accuracy of
analysis? A.
,i It represents accuracy and precision, and I would
say quite honestly in a laboratory like ours where we've
been doing it for seven years and where the same person did
the analysis on the 'same day on the same instrument, that
yes, these are pretty good results, and these are the kind
of results that a laboratory can achieve if they do Jt careful
` TRAN 028553
HARTOLDMON0042960
2070
1 enough in their own laboratory with well-trained analysts and
2 good equipment, good, well-tuned equipment -- and also with 3 pristine clear distilled water samples.
4 fr Now, are you familiar with any processes by which *
5 furans can be formed through dxidation of polychlorinated
6 biphenyls?
7 A. As an organic analytic chemist, yes, I am very
e familiar with organic chemistry and with the fact that you
9 can make furans, 10 ft Now, Exhibit 0 to the Monsanto testimony is the
n paper by Crosby.
.
12 A. I have it.
13
.0
1 will put to youthe samequestion that 7 put to
14 Mr. Papageorge.
15 On page 374 and 375, the statement is made that:
16 "Irradiation of chlorinated biphenyls
17 dispersed in water, followed by GC/MS, revealed
18 identifiable traces of 2-chlorodibenzofuran as a
19 photolysis product --"
20 I won't read the rest of the sentence.
21 Do you have the sentence in front of you?
22 A. Yes.
23 Q. Does thisindicate to youthat underirradiation frt
24
0
the sun in the environment, furans could be formed from PCB'c
Inc.
25 after discharge?
TRAN 028554
HARTOLDMON0042961
(Corr.)2871
1 A. I will say yes, the possibility exists, if 1 am 2 allowed to qualify that statement.
3.
In the experiment that Crosby performed, he could
4 have easily produced what -they call phenyl phenols# ortho-
A
5 phenyl-phenols; and when you put an ortho-phenyl phenol in
6 a gas chromatograph in An injection port that's hot -- and
7 I don't care whether it's glass or metal or what -- and you
8 have another chlorine that is ortho to that, you stand a good
9 chance of producing in the instrument a furan; and I've dis
10 cussed this problem with many people.
11 I'd also like to go on in this particular article
12 and read some more of his quotations, because I want to make
13 sure that the relevance of this to an environmental situation
14 is established.
15 First of all, on page 373, to indicate that you
16 can form phenyl phenols through hydroxylation, and that all
17 these things are subject to photodegradation -- even the furans
18 . if they are indeed produced in the environment, and there
19 have been people who have looked for them and not found them -
20 it saysi '
21 "Previous work in this laboratory demon
22 strated that chlorinated aromatic compounds are
23 reductively dechlorinated readily in organic sol
24 vents when irradiated with UV light at sunlight
Inc
25 wavelengths. Under similar conditions, irradiation
TRAN 028555 HARTOLDMONOQ42962
287?
1 in aqueous media results in replacement of the
2 chlorine by hydroxyl as well a9 by hydrogen."
3 This points out the fact that there is a pot sibil it.'A of forming phenyl phenols which, as I indicated, if you treat
5 them --- if you heat them you can condense them and produce
6 furans in the instrument. So you have to be damn careful
7 on this type of thing.
`.
8 1 would like to also turn to page 375 -- and let
9 me just review this very, very shortly.
10 (Pause.)
11 Okay. The bottom paragraph starting out, as J
12 said, on page 375, it starts out, and I would like to read
13 it t
14 "The photodecomposition of the lower
15 chlorinated PCB isomers in both polar and nonpolar
16 solvents reveals the operation of environmental
17 . . mechanisms which could effectively degrade these
18 widespread decontaminants."
19 The point is, we can have other than biological
20 degradation that accounts for peaks not appearing in rosidues
21
' V* and in water; and I would say, as he goes on he sayst
22 . "Indeed, the notable absence of the
23 lower chlorinated biphenyls from most environment
24
Inc.i
25
al samples
'
%
And he is referencing our referenoe 9 which is this
- TRAN 028556 HARTOLDMON0042963
2873
1 huge, magnificent study that was carried out by some zeal 2 competent people. 3 is suggestive of an important role of 4 decomposition in the environmental fate of PCB's, 5 the interpretation of their source and movement, 6 and prediction of toxic effects on aquatic life," 7 i.e., he is again saying there i6 a mechanism other than bio 8 degradation for degradation of these materials.9 And, incidentally enough, the higher chlorinated 10 biphenyls absorb the kind of light that passes through our 11 atmosphere to a greater extent than the lower chlorinated 12 ones, bocau6 you get a shift toward higher wavelengths, 13 absorption wavelengths, as you increase the chlorination of 14 the biphenyl molecule. 15 Ci Doctor, your testimony has been very helpful , and 16 I want to thank you. 17 MR. ECKERTt I have no further questions. 18 MR, PARK! Could I have one half minute? 19 JUDGE SWEENEYi Yes. 20 (Pause.) 21 22 23 24
IftC.
25 TRAN 028557
HARTOLDMON0042964
2874
I do have ono question.
1
2 . REDIRECT EXAMINATION
3 BY MR. PARK:
4 Q. Dr. Tucker, yesterday you may recall there were a *
5 few questions concerning sampling and the problems that might
6 bo created by improper sampling, or, perhaps, improper hand
7 ling of samples.
.
Could you clarify this subject of sampling and-
8
analysis of samples, please?
9
10 A YeB. I think it is an important thing that we're
11 all approaching, and something we ought to address ourselves
s
12 to is, wc ought to resolve sampling problems and, of course,
13 analytical differences in our laboratories, if vo'rc going
14 to got into the enforcement area which -- we aren't there,
15 obviously.
16 But it was touched on yesterday, and it wao asked,
17 you know, sort of, why was campling such a problem? And we've
ID done a lot of sampling in our plants. And we have found that |
19 -- and to make the statement in here, and I would like to
20 just add to it a little bit.
21 We found that the type of sampling that one applies
22 can affect drastically the results that you get in terms of
23 what's coming out of the plant. So obviously, if it doesn't
24 represent what's there, it can be the high or low, so you can
tnc.
25 have real problems. So you have to design the system for
TRAN 028558
HARTOLDMON0042965
dr-2
O
i 2 3
4
5 6 7 8 9 10 11 12
(. *
13 14
15
16
' 17
18
19
20
21
22
( : 23
24 Ac*'f+<i*iol Rrporitti, lot.
25
?R 75;
each plant? in other words, you have to 90 in and look at J tand make sure you're doing it right.
Also, I note that there's a frequency designated in the Federal Register for sampling. And I think that this should be looked at very closely, as to wether or not it is the correct frequency for sampling.
We have also found that, in sampling our discharges that the depth at which you cample -- I mean vertically, also, horzontally -- can make the results vary by orders of mngnitude. We've found that if we sample where turbulence versus where we have quiescenct conditions, you can get just total differences.
Also, the particulates are extremely important in terms of how you sample -- the size of the particulates in the stream, and things of this sort.
Also, I think that in industrial effluents, espec ially industrial effluents like Monsanto's,, that the efflu ent is extremely more complex than you find out in Lake Michi gan or in other orea6. So that you have to be exceedingly careful in the identification and the quantification of what you see? because in the world there are a lot of other things
t
that are electron-capture active. 1 also think that we're really going to have to
look at whether grab sampling, which is recommended, is reall right and whether or not we shouldn't really get into isokine
. TRAN 028559 HARTOLDMON0042966
207G
i
dr-3
1 tic continuous sampling, v.'hich is probably the ultimate in
2 this kind of thing.
3 At the same time, in terms of frequency, we
A mentioned the rainwater problem that brings up backgrounds and
5 things of this sort that can give erroneous results* All i can
6 cay is that as wo go down the road, that we've got an awful
7 lot of work to do, and I hope wo can all cooperate.
`
8 MR. PARK* That would conclude our examination here, 9 your Honor, but 1 would like to just make sure the record does
10 contain my objection to the failure by the EPA to question Dr.
11 Wright on toxicology, since he is here present, and ask him
12 the questions he had asked of Mr. Papageorge. 1 object if ( : 13 they fail to do so now, since he is available.
14 JUDGE SWEENEY You're excused. Dr. Tucker.
15 (Witness excused.)
16 MR. ECKERT: Do you recall specifically the ques^ '
17 tionS?
18 I have my questions all laid out.
19 MR. PARK: There were a few related to page 11, Mr.
20 Eckert. I think the bottom two thirds, perhaps.
- 21 MR. ECKKRT: Oh, yes. Right.
22 MR. PARK: 1 think if Dr. Wright could testify for
23 just a few minutes, it would be appropriate.
. 24 AtTdrol Kcportcu, Inc.
25
MR. ECKERT: All right. 1 think a couple of gues-tions for Dr. Wright would put this in `place.
' *
'
TRAN 028560
HARTOLDMON0042967