Document R4qEbZkLzQkn4n1yxkOGVvDB
INTER-OFFICE CORRESPONDENCE
h*-' J ^^----3l REFRACTORIES
TO
Glen Prible
SUBJECT
Insulating Cement Types
FROM-DATE
p. E. Jones May 15, 1972
Insulating cements required product line can be covered by two different types of products, namely
1) Thermal insulating cement (no cement) and 7/'
2) thermal insulating finish cement (has cement). ;L'n
The thermal insulating cement mainly has two specifications to
meet, which aSASIM C-195 and Mil-C-2861-D. The key requirements are:
1) Covering capacity wet of 50 bd. ft. per 100 lbs. of dry material
2) Drying volume shrinkage of less than 20 percent
3) Shrinkage at 1800 F. less than 37o and density of less than 30 lbs. per cubic foot.
There are other required properties such as thermal conductivity,
dry adhesion to steel, mechanical stability, compressive strength
and corrosion effect on steel. Super Stictite was qualified for
Mil-C-2861-D and Stictite was not, as it mainly failed dry volume
shrinkage and mechanical stability tests. The main reason Super
Stictite has been used was it is much smoother to feel and jobs
requiring workers to use their hands in the material,, .this jaate-
rial was supplied as we usually received complaints with Stictite
when used this way.
Aue. fe 4-Ifee*- A
Thermal insulating finish cement has only ASTM C-449 specification to meet. Utility finish cement meets this specification.
Copies of these specs, are here if you wish copies.
Very truly yours.
PEj/fw
PLAINTIFF'S EXHIBIT
CE0102771
CE/HI (F) 32908
PLAINTIFF'S EXHIBIT
^bioi.oo
INTER-OFFICE CORRESPONDENCE
EsE REFRACTORIES
S/22/72 Xerox to: W. P. Coon
TO
F. Steimke
CC: R. Hegeman W. Bennett G. Andrews T. West L. Jacobs
SUBJECT
Insulating Cements
FROM-DATE
Glen V. Prible May 18, 1972
Dear Frank:
After our discussion Monday morning in regard to dropping and retaining certain insulating cements and finishes, I have dis cussed with Paul Jones the requirements for insulating cements and difference in their properties. Paul has summarized the requirements and some of the properties in his letter to me of May 15, 1972, copy attached. In summary. Super Stictite and 711 theoretically meet the requirements of the A.S.T.M. and the Mil specifications. Stictite does not meet this requirement.
It is engineering's recommendation that the insulating cements and finishes to retain are as follows:
Super Stictite
711
Utility Finish
All other manufactured insulating cements and finished should be irrevocably discontinued. Thank you.
GVP/fw
P.S.--Total sales for 1972, first four Accounting Periods:
Super Stictite Stictite Utility Finfsh
711
Others
116 tons 78 tons 56 tons 94 tons 0
CE0102772
cs/HKm*909