Document R2j9JM5N7Qavw919My1zYe9X
FOR
Mr. John W. Ward, Vice-President Kaveg Industries, Incorporated 900 Greeribank Road Wilmington, Delaware 19808
August 22, 1966
CONCERNING
900 Greenback Road Wilmington, Delaware
SERVICE BY PERSONS CONTACTED
W. J. Uber, industrial hygiene consultant, and C. J. Ehrhart, safety consultant, on August 2, 1966
W. U. Reybold, plant engineer Helen Fraticelli, R.N.
REPORT SUMMARY
Industrial Hygiene Survey
"We called on this policyholder to review the proposal for a new materials handling system in the asbestos treating "department. Our study of the asbestos dust hazard had indicated that additional controls were required to reduce the concentration of airbom asbestos dust to which workers were exposed.
"An index of performance for the dust collectors is the static suction pressure
produced on the clean and dirty sides of the collector, and we suggested the
use of a permanently mounted manometer connected to both sides of=jfche-collector
for easy determination of these pressures. Mr. Reybold will provide for this
gaging device.
--
"Mrs. Fraticelli, R.N., reviewed for us the status of chest X rays, which are on schedule for workers exposed to asbestos.
"We suggested to Mr. Reybold that when the modifications to the asbestos handling
system have been completed and the weather is cold enough to operate with doors
and windows closed, a follow-up asbestos dust study be performed, and this will
be arranged*"
-
- ...
HO 85
cc: Mr. H. B. Haney; Mr. W. U. Reybold
This confirmation of service concerns only such conditions and practices as were observed and considered at the time of this call. It is not intended to indicate that all other hazards are adeauatelv controlled.
j j
If you hare any comments or questions con
cerning this report, write to C. H. Elsby,
Vice-President, Safety & Health Services.