Document R2d6OQyEj2mLJekKJMxnnqRv7
Heating Systems F?ttSgTd
Hammond Brass Works HAMMOND, INDIANA
HAMMOND VALVES--A complete line of packed type radiator valves for steam, gravity and circulator hot water systems--balancing elbows and fittings for forced hot water heating systems and floors, celling, and wall radiant panel heating. Hammond Circulator Valves, Balancing Elbows and Fittings for Forced Hot Water Keating Systems. For Iron Pipe and Copper Tubing.____________ ________________
Service Recommendations No. 201--
Circulator-Male Union and Sweat Con nection. Provides a "nearly tight" shut-off when closed and full flow when
opened. A quarter turn of the handle
permits the valve to be opened smoothly and easily. No. 202--Circulator-Male Union and Sweat Connection. For forced hot water
systems only. Particularly suited for use with concealed or "convector type" radiators, which installation frequently,
requires a valve for the lower vertical
radiator tapping. A quarter turn of the
handle permits the valve to be opened smoothly and easily. No. 308--Copper to copper balancing
ells for panel heating.
No. 301--Balancing Elbow-Male Union
and Female Thread. No orifices or adap tors are needed when this elbow is used.
The external adjustment allows for ad
justing and readjusting while the system is in operation and eliminates inconveni ence of draining.
No. 302--Union Elbow-Male Union with Sweat Connection. Can be used on cop
per tubing gravity jobs and also where
the supply valve is adjusted, but we do not recommend adjusting any system at
the inlet. No. 305--Balancing Fitting-Male Union
and Female Thread. For concealed or
convector type radiators. No. 308--Copper to copper balancing
ells for panel heating. No 100--Steam Angle. Can also be used
for vapor.
Hammond Radiator Valves and Elbows for Steam and Gravity Hot Water Heating Systems. For Iron Pipe and Copper Tubing.
No. 101--Steam Corner. Same as No. 100. Specify whether right or left hand
wanted. Valve illustrated is left hand. No. 102--Gate Union. For hot water installations and steam or vapor heat
ings systems. Especially suitable for
use with unit heaters; ideal for general shut-off valve service at other points throughout heating systems including
boilers and hot water heaters. Specify when ordering for hot water system, as
such valves are furnished with a small
hole drilled through the disc to provide for slow circulation when valve is closed.
No. 105--Convector Single Union Gate. Same as No. 102, but single union does
not permit removal of radiator while system is in operation. No. 108--Convector Female Union Steam Angle. Same as No. 100, but should only be used for convector radiators equipped with inside leg tappings. The female union eliminates the necessity for exact roughing in measurements to tapping.
Variation of the nipple inside leg will allow for adjustment. Shipped with bonnet loose to facilitate installation. No. 300--Union Elbow--For gravity hot
water heating installations. No. 104--Double union gate for convec
tor radiators only.
See Hammond Catalog for complete line of valves.
Warehouse stocks located in 29 cities throughout the United States for your conveni
ence and prompt delivery, at our regular prices and terms.
1508
Heating Systems Valves
Homestead Valve Manufacturing Co.
P.O. Box 127
"Serving Since 1892"
Coraopolis, Pa.
'Makers of Radiant Heating Valves and All Kinds of Plug Valves
HOMESTEAD-RADIANTROL VALVE
The Combination Balancing Valve and Air Vent for Radiant Heating Systems
Provides control of room temperatures to meet varying requirements.
Is designed for simplicity and con venience of adjustment; and
Engineered for ease and low cost of installation.
Homestead Radiantrol Valves are but terfly type valves, which permit slight passage of water in the "closed" position.
A quick quarter-tum fully opens or closes the valve. Graduations between "open" and "closed" positions give in stant choice of amount of hot water for each panel. In "open" position valve provides nearly full pipe area flow.
In the simplest sense, the Homestead Radiantrol Valve performs the same function for each radiant heating panel as the manual valve on a radiator, or the shutter on a hot air grille. It controls the flow of hot water to each panel or room in accordance with the varying heat requirements caused by differences in types of floor covering, changes in wall or ceiling construction, addition or elim ination of storm sash, individual likes and dislikes, etc.
The Homestead Radiantrol Valve is an unique combination balancing valve and air vent for radiant heating systems.
It saves up to $25 per panel in instal lation costs through:
1. Eliminating cost of making spe cial valve "wells" and covers.
2. Eliminating need for separate riser air vents.
Chamber in neck of valve body is es pecially designed to collect, trapped air without restricting flow. Vent screw on valve cap provides simple means of re moving trapped air from system.
The Radiantrol Balancing Valve is a "must" for any radiant heating system -of more than one panel in order--
1. to insure proper flow needed to offset, the various heat losses en countered; and
2. to remove air from each heating panel.
Valve bodies are made of wrought iron, steel, or brass pipe with beveled or sweat ends for welding or soldering.
Valve floor plates may be,, had with locks to prevent tampering; or with positive adjustable stops to limit open ing and save rebalancing system.
Radiantrol Valves are available in either foot-control or hand-wheel types; sizes $ in., $ in., 1 in. and 11 in.
It controls heat in each panel; and Write for complete catalog. Reference balances heat between various panels. Book 39-7. No obligation.
1509