Document R2XEQKXyBXgmjk9Z2957rpvJ7

Pollution Control- Full-time Program At Weirton Steel By RICHARD l. DUNN, Associate Editor, Plant Engineering Magazine EVERY WORKING DAY, Houston Wood goes to a morning staff meeting. Weirton Steel's-top man agement is all there or represented. A portion of the meeting is devoted to operating activities, and Wood gets a rundown on the plant's activities for the next 24 hours. ' Wood needs this kind of information. He has to know what's going on at all times. And he has to evaluate each activity for its possible influence on Weirton Steel's pollution control efforts. HoustonR. If there is anything going on within the company Wood is Supervisor of Environmental Control that has a bearing on environmental control, Wood r A steel-pfoducing planfthat uses 230 million gallons knows about it. He attends the morning meetings to of water (enough to supply a city twice the size of keep up with daily happenings because whatever is Pittsburgh, Pa.) each day, and removes more than 25 going on may affect Wood's activities. If the day's plans tons of dust from exhaust gases every hour, makes call for an oil change on the tandem mills, for example, pollution control a big job. Wood draws on over 12 I Wood knows this could cause problems in the oil treat- years' experience in the field to accomplish it. E ment system. With this prior knowledge, he can take Weirton Steel, located in Weirton, W. Va., which I action to prevent what might otherwise become an nestles in the Ohio Vaiiey between the Pennsylvania | embarrassing incident for the company. and Ohio borders, has been fighting pollution for de Wood's attendance at the morning meetings is a cades. In 1953, one man began working full-time on prime example of Weirton's pollution control philoso the problem. Tom Millsop, then Weirton's president and mayor of the community, felt that the company phy at work. Weirton officials believe that the most important single factor in keeping pollution control had to do more than it was doing in the way of air problems at a minimum is constant communication. pollution control simply for the good of the commun This communication must cover the entire width and ity. "With his direction, the company kind of got or depth of the company. For example, Wood on the ganized." Fred EL Tucker, Manager, Pollution Control division level maintains close, personal contact with and Services for National Steel, welrtniffs parent cor Tucker on the corporate level. poration, explains. ^ "You have to have this communication with top "From that humble beginning, Weirton Steel's pollu management to know what's going on and what's going tion abatement activities have grown until, today, to happen," Tucker says, "because they're the only I IWood has a full-time staff working for him. His people who know what's going to happen." And, on I chemist, environmental engineer, chemical analyst, and the other hand, he emphasizes the necessity of having chemical supervisor help him locate, identify, and eval- a good rapport with the people out in the plant. "A guy : uate problem areas and plan for their control. The on night turn, if he's not concerned about pollution, chemical supervisor also runs Weirton's own effluent can easily throw a drum of oil down the sewer and j sampling and analysis laboratory. foul up the river for the next two days," Tucker - 66- PLANT ENGINEERING, FEBRUARY 19, 1970 DS\N 552279 STLCOPCB4090696 EDITORIAL COMMENT DOLLARS BLOWING INTO THIN AIR? "A penny saved is a penny earned." Old advice and still pertinent. But how closely is it heeded in a typical industrial plant? Take your compressed air system, for example. How many pennies--add ing to dollars--are literally blown into the atmos phere every operating hour in your plant through compressed air leaks in tools and accessories? Among the causes of leaks are: 1. Equipment that is not rugged enough and starts leaking a short time after it is put into service. 2. Abuse by irresponsible users. Mistreatment can be detrimental even to good design. 3. Insufficient concern about compressed air leaks which magnifies other problems. To cope with the first cause, simply buy products of top quality. If you are not sure which manufac turers' products to buy, purchase similar items from several different manufacturers and run your own service tests in similar applications. Then establish your preference for equipment that gives the best performance. Top quality products provide part of the answer to the second cause--abuse. The other part is to train users in the proper care and become more careful about proper handling of pneumatic equip ment. Ask the foreman of such departments to acquaint their men with the problems and ask their coopera tion. Ask the accounting department to send monthly reports to each production department foreman of costs charged to his department for repair and replacement of pneumatic equipment. Thus, he will have comparative yardsticks of what is happening in successive periods. Costs going un reasonably out of line should spur him into action. Finally, to remedy the neglect of leaking equip ment, assign one or more individuals to periodically check equipment for leaks. Whenever possible, checking in each department should be done when it is not operating--with the compressed air lines under pressure--so that leaks can be more readily detected. Even as you are reading this, those pennies may be disappearing into thin air. By doing nothing, losses will mount into dollars. So start plugging those leaks and keep those dollars from blowing away. 1 -4-Circle 550 on Post Card DSW 552280 FEBRUARY 19, 1970 PLANT ENGINEERING 65 STLCOPCB4090697 Above leit: Water used for cooling and stack cleaning in Weirton Steel's basic oxygen process mill is held in clarifier tanks to allow solids to settle to the bottom. Of the 50 million gallons of water the mill uses daily, 45 million gallons are recirculated within the plant. Above: Chemists conduct 24-hour surveil lance on Weirton's wastewater by analyz ing the samples in their own laboratory. Right: Weirton's Kish system collects particle-laden air during the transfer of hot metal from railcars to ladles and feeds it to a baghouse outside building. 1 FEBRUARY 19, 1970 PLANT ENGINEERING 67 DSW 552281 STLCOPCB4090698 The oil recovery and water purification system .at Welrton's Hot-strip mill enables the company to recover and re-use much of the rrilfl's oil wastes. > Capsule of Pollution Control Activities Air and stream pollution control touches virtually all operations in the steelmaking process at Weirton. A summary of Weirton's major pollution abatement systems gives an indication of the vast ness of the program. Dust from the BOP steelmaking and hot metal charging opera tions is controlled by two venturi scrubbers that have the capacity to remove 180 tons of effluent per day. Electrostatic precipitators are capable of cleaning 7,500 tons of air per day from two open hearth furnaces. Phenol emissions from 294 coke ovens are controlled by one of the most advanced phenol recovery plants in the industry. Besides the 3,500 lb of phenol recovered each day, the plant also recovers tar, oil, and ammonia. The ovens use about 22 million gallons of water and 80.8 million cu ft of air per day. The company's four blast furnaces are equipped with a complex dust control system which includes dust catchers, gas washers, precipitators, and venturi scrubbers. The 22 million gpd of waste water is cleaned by two large clarifiers. Rotoclones, cyclones, and a chemically treated wet water system remove 10 tons of dust per hour from the two sinter plants' exhausts. The strip steel tandem mills are equipped with an oil recovery and water purification system which provides reclamation of used oil. A system for acid mist elimination, oil recovery, and recircula tion and containment of chemical waste provides effluent control for the sheet mill and tin mill. (The tin mill uses 10 million gallons of water per day.) The coal preparation plant employs a recirculating and cleans ing system to eliminate any undesirable black water discharges. The operation recovers 2,000 tons of sludge every month. Weirton spends $1,500 per day to dispose of 70,000 to 100,000 gallons of waste pickle liquor. The company is exploring deep well disposal and acid recovery as a means of reducing this cost. POLLUTION CONTROL IS FULL-TIME PROGRAM points out. Weirton's personnel strive to prevent this type of occurrence. Wood's responsibilities as Supervisor, Environ mental Control, include all air and water pollution control, industrial hygiene, and solids disposal. Al though he is often involved with costs and cost esti mates, his primary function is to act as an independent control official within the company advising manage ment on all matters dealing with his responsibilities. He doesn't decide what equipment to buy or how much to spend, but he does make recommendations on what device should be used. The engineering division selects and buys all equipment with the advice of the environmental group. This link with other management areas allows Wood to be objective, and the relationship works to Weirton's advantage. Weirton is within a recently designated interstate air quality control region, but Wood is already trying to set levels for plant effluents that will meet or exceed the new criteria when they are established. Wood has studied several regions and States where air pollution criteria are now in effect. "We've tried, in our own minds," he reasons, "to decide what the criteria will be here. Then we're trying to use those numbers we 68 PLANT ENGINEERING FEBRUARY 19, 1970 think they'll come up with on our particular installa tions." Such advance planning is not new at Weirton. Tucker states that "Weirton has always tried to antici pate where the problem areas were--the most serious problem areas--and it has always tried to do some thing about them before they become a problem for public concern." Wood now has a project underway using matching federal funds to try to anticipate what the problem areas are going to be in four to five years and what Weirton can do about them. These problem areas concern low-flow, highly con centrated wastes that might lend themselves to treat ment in the city's water treatment plant. The city has a primary treatment plant which, in all likelihood, will have to be upgraded to a secondary or tertiary plant in the next several years. So, using the federal funds, Weirton Steel is studying the possibility of building an addition to the city's treatment plant which would treat a number of the company's wastes and at the same time upgrade the city's facilities. The company con siders this a significant program and is very optimistic about it. For advance planning of pollution control to be meaningful, the company must have information not I "~ ! DSW 552282 STLCOPCB4090699 VICE PRESIDENT INDUSTRIAL RELATIONS AND SECRETARY MANAGER POLLUTION CONTROL AND SERVICES ( WATER AND AIR) FRED E. TUCKER T~ WEIRTON STEEL (PRESIDENT) (CHAIRMAN) begun to correct it. In some cases, the engineering staff may design it; in others, they'll get the supplier of the equipment to engineer it; and in still others, they'll hire I a consulting firm. Or, as with their palm oil recovery, j they'll have a contract service treat or haul the problem , .away. Weirton's men enjoy thisTreedom from set pro MANAGER INDUSTRIAL RELATIONS cedure and welcome the opportunity to try new meth ods. Weirton's belief in the continuing need for effective SUPERVISOR ENVIRONMENTAL CONTROL HOUSTON R WOOD pollution control is manifested in its cooperative train ing program. Wood normally has two students working for him under this program but has had as many as six. He extends Weirton's pollution control education program by using summer students, encouraging per sonnel to attend courses and seminars, and participat CHEMICAL SUPERVISOR CHEMIST ENGINEER CHEMICAL ANALYST ing in the company's management-training program and speakers bureau. Weirton's most aggressive_.environmental control LABORATORY project to date has been the construction of its new "Mill of the Future" designed for basic oxygen pro cess (BOP) steelmaking, vacuum degassing and large- scale continuous casting. Of the four main interdepend ent systems in this 26-story, 8-acre mill, three could be classified as pollution control systems. The gas scrubber system cleans the gases evolved during the steelmaking process and ventilates the furnace shop. The waste heat boiler system captures waste heat for plant use and only on its own requirements, but also on possible regulates steam through the various circuits. The total , legislation. This is Tucker's assignment. "It's my re- waste treatment and recirculation system provides the | sponsibility to anticipate what's coming next and de 50 million gallons per day required by the mill.jiighty- i velop long-range planning for corporate air and water six per cent of the cooling water is recirculated for use [ quality control," he says. Again, communication is the in thefurhaceshop, vacuum degasser, and continuous key factor. Tucker has the company's library route to casting unit. him any information it receives concerning pollution Weirton Steel believes that proper control of pollu control. He also placed his name on many mailing lists, tion and wise management of water is a demonstration including those of the government. In addition, he of responsible corporate citizenship. Houston Wood belongs to several organizations and committees in and Fred Tucker help make this philosophy a reality. volved with pollution control work, including the Iron Senator Jennings Randolph, chairman of the Senate 1 and Steel Institute Committee on Natural Resources Special Subcommittee on Air and Water Pollution, and the U. S. Chamber of Commerce Committee on brought Weirton's diligence to public attention when Natural Resources. he reported to the U. S. Senate, "If all industrial Wood and Tucker both maintain a good relationship management officials were as progressive and civic- with State officials. Phrases like "We work with the minded as are those of Weirton Steel, and if all State State to establish what needs to be done. . . . We and local officials were as conscious of their responsi negotiate continually with the State . . . We're in bilities in the field of pollution control as are those now constant communication . . ." come up often when serving in West Virginia, the Congress would perhaps they are talking about new company plans or new regulations. Weirton has no "formula" for pollution control not need to act on federal standards for ajr and water quality." End DSW 552283 problem-solving. Each problem is treated individually, and seldom is a new problem attacked with an old approach. When the problem is identified, planning is Want a copy of this article? Please turn to page 4. FEBRUARY 19, 1970 PLANT ENGINEERING 69 STLCOPCB4090700 Planning for Materials HandlingKey to Company Expansion By ROBERT O. PROCHASKA, Materials Handling & Packaging Consultant, P & W Engineers, Inc., Chicago, III. THE STIMULUS GIVEN plant expansion may come from many sources--management, direc planning, the plant engineer will be working with architects and many department heads, sifting sugges tors, or customers. But no matter who is involved, tions, examining ideas, exploring proposals. one individual is certain to have a major role in com He may also be working in close coordination with pany expansion plans--the plant engineer. consulting engineers. Consultants can provide assis Planning for materials handling will be a key part of tance in analysis of handling procedures, equipment this expansion and, like all other aspects of plant selection, and in the design of a complete handling planning, it has become increasingly complex. Manu system. If such help is needed, it should be retained facturing has reached a high degree of sophistication early in the planning. as its production techniques become faster and more An initial plan for the task is most important and complicated. These advances, and constantly rising includes: costs, demand constant review. 1. Establishment of objectives. This is usually the While some of the points covered in this article are prerogative of management. Does it, for example, seek ' general, many apply specifically to materials handling, to increase production by 50 or 100 per cent in the ' one of the many provinces of the plant engineer. They next five years? emphasize that this phase of planning must receive 2. Determination of present capabilities. attention on a level equal to production. In layout 3. Evaluation of present capabilities in relation to Fig. 1. Basic flow chart should be included in preliminary planning to aid in layout. Fig. 2. A detailed flow chart eliminates backtracking of parts. Machines should be arranged for straight-line flow to move parts directly from receiving to shipping area. r RECEIVING n 4, INSPECTION - --'1r WAREHOUSING .. > -f 1mete PRODUCTION ------- +1 PACKAGING 11 " , nWAREHOUSING SHIPPING BASIC FLOW CHART INPUT 70 PLANT ENGINEERING FEBRUARY 19, 1970 SECTION OF DETAIL FLOW CHART DSW 552284 STLCOPCB4090701