Document R2V3wa89y2V9XKjN05apvgGn
"TBPv-
Monsanto
OAM uirc'
TO
B._ C. Bosse. _W. G.-Krumurieh Plant:
April 17, 1975 ' RESULTS OF PLANT POLY-
URETHANE FOAM TESTING
: Mr. W. C. Engman
Cl K. E. Boucher H . L. Campbell P. E. Heieler H. Horner G. L . Johnson A . E . Leisy D. K. Lynch
J . P . Mieure R. H . Munch W. R. Richard J . R. Savage w. L . Sraul 1
- T2B
- TIB - T3A - B2SL
s. H . Voge 1
SUMMARY:
'
Following the success of research in using Polyurethane Foam
to extract PCB's from surface waters, Interest was expressed
in ascertaining how well foam would remove PCB's from a waste
stream on a plant scale. Tests, conducted at the Krummrlch
Plant, showed:
.
1) A single column of foam will reduce the PCB content of a waste stream from as high as 2000 ppb to <10 ppb, as will a single column of carbon.
2) The PCB content of a waste stream is not significantly reduced by passing It through a foam column after it has flowed through a carbon column.
3) Neither foam nor carbon consistently removed 1242 or 1254 perferenttally.
4) The loading capacity of the foam is estimated to be
.05 lb PCB_______________
.,
, 0.25 Ib/PCB
lb Polyurethane Foam va' carbon loading of lb Carbon
Carbon was found to ba superior to foam In:
1) Material and regeneration costs.
2) Risks Involved in operating the removal system. 3) Existing technology.
As a result, it is recommended that carbon be used to remove PCB's from plant waste streams rather than foam.
,7
,W' Jh..
t
1
HONS 029283
Hr. W. C. Engman RESULTS OF PLANT POLY URETHANE FOAM TESTING
Page 2 4/17/75 WGK
1. BACKGROUND
It: was found , on a laboratory scale, that lower PCB levels could be detected by extracting the PCB'g from a body of water onto Polyurethane Foam, than could be detected by adsorbing them onto carbon. As a result, interest was expressed in ascertaining how well foam would remove PCB's from a waste stream on a plant scale. Tests were conducted at the W. G. Krummrich Plant to accomplish the following objectives:
1) Find the level to which the PCB content of a plant waste stream could be reduced using a removal system containing Polyurethane Foam.
2) Obtain engineering design information.
II. TESTS CONDUCTED
Two systems were employed to accomplish the objectives of the plant testing:
1) A system in which sump water was fed to a carbon column followed by a foam column, the two columns being in series.
2) A system in which sump water was fed only to a foam column.
The following samples were taken and analyzed for PCB con tent :
1) The feed to each column
2) The effluent from each column
The flow diagrams on the pages that follow show the flow to and from each system and give Information about the equipment and materials used in the testing.
HONS 029284
------
P-age 4
/ *^]<rtfA -TAA/fl , y'/V7"
V
HONS 0 2 9 2 8 6
r--$4-1
Soap'S
fiMov>4UJs
r^P=3----------- N-
'f-fOfiH <lcloMKI, 3'tS^j ^Lgr^ / '
--------*^*2*2<UJ
5~ Afte/a . B^tn-T'S
-^
^CL&h*td*
1
'Sort?
'&y,-i-Ct^ra /
<y6&LaZZm>. ~ J~~
2^
Ojt?jUmyO. ^edZtb
zi&i
--------------- -
-*5< -a^25w -? g6hslZ^> Z&
fexsiin'M^
= /&> /* .................. ..........................................
(r.w/4
"C ,r H^T
^
-
-CM^- :^.{-r(^ :
c*^
,,] / 4y cu~cAa*>,
*
/<2fcv^/ -^a^w J-pal6
v /,
,'
' /&.
-w ^4^ ,,4 j^u> ^*^4
- 3'^ ^/rx =sr,
_ |/I^VWN. ^
< y-
Mr. W . C. Engmnn RESULTS OF PLANT POLY URETHANE FOAM TESTING
Page 5
4/17/75 WGK
III. TEST R.ESULTS
The results of the testing are shown graphically in plots 1 and 2, PP's 6 and 7 and in table form in tables 1 and 2 on PP's 8 and 9. The plots and tables show that:
1) A single column of foam will reduce the PCB content of a waste stream to <. 10 ppb as will a single column of carbon.
2) The PCB content of a waste stream is not significantly reduced by passing it through a foam column after it has flowed through a carbon column.
3) Neither the foam nor the carbon consistently removed 1242 or 1254 preferentially.
The loading capacity of the foam was found to be .053 lbs PCB/lb Polyurethane Foam. The foam, the same piece being! used in both systems, was cut into 3" diameter by 1" long sections and analyzed for PCB content. The results of the sectioning are presented below:
Segment of Foam
PCB loading Lbs PCb/Lb Polyurethane Foam
1st 2nd 3rd 60th
inch inch inch inch
. 049 .057
.036 4.32 x
10"A
Because of the accuracy of the method of analysis used, the first two segments can be considered to have the same PCB concentration. Consequently, the first two segments are assumed to be a measure of foam loading.
HONS 029287
f'uge 0 r
r
r
r
r
ni
*
O
r
I' a k e 1 MUNS 029289
DATE 12/23/74 12/31/74 12/31/74 1/3/75 1/6/75 1/7/75
TIME 2:20 P.M. 11:45 A.M. 2:05 P.M. 1:00 P.M. 4 : 30 P.M. 1:10 P.M.
POLYURETHANE FOAM TESTING, PART 11 DATA SHEET. TABLE I
Pg- 8
FLOW RATE GPM . 44 .48 . 41 . 36 .26 .12
TOTAL CUMULATIVE HOURS OF
COLUMN OPERATION
5.6
9-6
12.9
17.9
28 32
FEED 800 1454 2038.5 289.8 333.4 227.7
PCB CONCENTRATION (PPB)
CARBON EFFLUENT
FOAM EFFLUENT
13.5
10.9
-c 1 -c l
3.2 1
4.8
3.4
4.2
2.4
2.6
.9
1/7/75
1/8/75 1/9/75 1/10/75
8:15 P.M.
4:15 P.M. 5:00 P.M. 5 : 00 P.M.
operation of FOAM COLUMN ONLY
. 30
38.1
390.3
--
Considerab1e channeling when above data was taken
.40 44 . 9
701.5
--
.40 49.4
604.2
--
. 34 73.4
725
--------
'
21.5
1.3 7.7 6.4
HONS 0 2 9 2 9 0
T 6 ? 6 ? 0 SNOW
DATE 12/23/74 12/31/74 (1) 12/31/74 (2) 1/3/75 1/6/75 1/7/75
1/7/75 1/8/75 1/9/75 1/10/75
POLYURETHANE FOAM TESTING. PART II BREAKDOWN OF PCB*S IN VARIOUS SAMPLES
TABLE II PCB CONCENTRATIONS, PPB
Feed to system
1221
1242
1254
--
339.3
459.9
-- 833 621
554.6
596.5
887.4
61
83.9
144.9
--
138.1
195.3
-- 105 122.7
Carbon effluent
1221
` 1242
1254
--
3.9
9.6
-- ^1
<1
--
2.4
0.8
0.9
1.5
2.4
--
0.7
3.5
--
0.7
1.9
OPERATION OF FOAM COLUMN ONLY
-- 282 108.3
--
426.9
274.6
--
293.7
310.5
--
34 7.8
377 .2
Pg. 9
1221
--
--
--
0.9 ---
1242 4.2
<1
1.0 0.3 0.8 0.3
1254 6. 7
-a
_
1. 7 1.6 0. 6
_ 7.7
13. 8
--
1.0
0. 3
--
4.2
3.5
1.0
5.4
Mr. W. C. Engman RESULTS OF PLANT POLY URETHANE FOAM TESTING
Page 10 4/17/75 WGK
IV. A COMPARISON OF TOAM VERSUS CARBON FOR REMOVING PCB'S FROM * A WASTE STREAM
Table III. pp's 11-12, compares carbon and foam with regard
to various items important in selecting a material to remove
a contaminant from a waste stream. All carbon data Is based
on a loading capacity of 25Z, a result obtained from carbon
work at Anniston.
*
In the WGK plant testing the only way the foam could be packed into the column was by:
1) Wetting the foam with water
2) Tieing strings around both ends of the foam and pulling it into the column.
how packing would be achieved on a large scale unit is unknown.
V. RECOMMENDATIONS* 1 2
It is recommended that carbon be used to remove PCB's from a plant waste stream rattier than foam because:
1) The c o 81 s involved in using a carbon system are much less than those which would be incurred if a foam system was used:
A. Material Cost:
Foam coat/lb. PCB removed is approximatley 90 x greater than the carbon cost/lb PCB removed.
B. Regeneration;
1) Initial -- cost of solvent to regenerate foam is $2500/lb PCB removed. No solvent is required for carbon regeneration.
2) Assuming 95X solvent recovery -- cost to regenerate the foam Is 125 x greater than the co81 to regenerate the carbon.
MONS 029292
Mr . W. C. Engman RESULTS OF PLANT POLY URETHANE FOAM TESTING
Page 11 4/17/75 WGK
TABLE III - A COMPARISON OF CARBON VS. FOAM
1 tern
Foam
Carbon
1) Ability to remove PCB's
Reduces the PCB concentra tion of a waste stream to <10 ppb
Reduces the PCB concentration of waste stream to <10 ppb ,
a
2) Initial material coat of adsorbent
. , JL
- 3) Amount of adsor bent needed:
$147/lb PCB removed and a $325 tooling cost to purchase the tools needed by the fabri cator to fabricate the foam into a circular piece. A cost will also be incurred for tool replacement should they wear ou-t.
$1.60/lb PCB removed
9.4 ft? foam lb PCB removed
.13 ft~* carbon lb PCB removed
A) Loading B) Density C) Surface Area
.053 lb PCB/lb foam 2 lb/ft3 1.3 x 103 ft2/ft3
.25 lb PCB/lb carbon 30 lb/ft3 1.7 x 108 ft2/ft3
4) Cross sectional area of adsorbent per gpm flow
.14 ft2/gpm
.14 ft2/gpm X
These figures are based on: 1) The diameter column used
in the WGK plant testing, 3".
2) The average flow rate used in the WGK plant testing, .35 gpm. This may or may not be the optimum flow rate for PCB removal in the size column used.
r.,u/4;
C,cC
V
1 * >c r-
l
c. (CC- ^ Pa >
XF-
HONS 029293
Mr. W.- C. Engman RESULTS OF PLANT POLY-
URBTHANE FOAM TESTING
Page 12 4/17/75 WGK
TABLE III I cam 5) Regeneration Cost
6) Chemical Resis tance
7) Technolgoy
COMPARISON OF CARBON VS. FOAM (Cont'd)
Foam
Carbon
Initial coat - $2,500/lb PCB removed. Baals:
1) Regenerating solvent Freon TF by DuPont which costa $.60/lb when shipped in a 690 lb drum. This material is not presently shipped in tank car.
Roughly $ 1/lb PCB removed based on furnace regeneration The exact mode of regeneration though, and whether replace ment is more economl cal is dependent on the specific removal system.
2) Volume of solvent needed to regenerate the foam -4.5 x the volume of the foam.
Freon TF is not a proven solvent for regeneration but a suggested one by Dr. R.H. Munch. Freon TF can be used indefinitely. Assuming a 95% solvent recovery, the cost would be $125/lb PCB removed.
This does not include the c o s t for the design, instal lation, and operation of a solvent recovery system.
Attacked by strong acids, caustics, and chlorine. Aliphatic hydrocarbons cause slight swelling and aromatics cause considerable swelling. This information was supplied by the Scott Paper Company.
Not attacked by strong acids, caus tics, chlorine, ali phatic hydrocarbons or aromatics.
Much filtration work has been done by the Scott Paper Co. with air. Monsanto, for the most part would have to develop its own foam tech nology for PCB removal.
Technology developed
MONS 029294
Mr. W. C. En gman RESULTS OF PLANT POLY URETHANE FOAM TESTING
Page 13 4/17/75 WGK
V, RECOMMENDATIONS (Cont'd)
2) Carbon technology has been developed thereby lowering the risks involved in using a carbon system to remove PCB's.
3) Major risks would be involved in using foam to remove PCB * s s
A) How to pack the foam into a large column.
B) Chemical attack of the foam by various known chemi cals which may be present In the waste stream.
C) Monsanto would have to develop, for the most part, its own foam technology.
VI. ACKNOWLEDGEMENTS:
My special thanks to Steve Vogel who assisted in the plant tests. Steve's suggestions and ideas were very helpful.
/ tm
/3r*V-*^L* Z3&C&LS
B. C. Bosse Technical Services Department
HONS 0292^5