Table 7-B (1977)
Facility G Fiber Air Sample Results
Optical Microscopy
Operation/Area BRAKE REBUILDING Brake Mechanic I
Brake Mechanic II Brake Mechanic III RELINING DEPARTMENT Rivet Operator
Punch Operator
Partsman
Sample #
D-3 D-8 D-13
D-4 D-7
D-15
D-2 D-6 D-9 D-10 D-14
D-12 D-16 D-17
D-5
Volume (liters)
240 246 280
184 512
272
160 184 106 168 296
100 126
66
400
Time (min)
Concentration Fibers > Sum/cc
120 1.09 123 3.24 140 0.804
TWA 1.68
92 0.289 256. 0.62
TWA 0.53
136 0.52
80 2.0 92 5.59 53 7.53 84 6.84 148 2.68
TWA 4.47
50 7.31 63 5.90 33 10.92
TWA 7.52
200 1.21