Document R237XXVLgm7Z3gmDekQpEa7Qz

Airborne Contaminant Acetone Alumina Ammonia Antimony PentachJoride Asbestos Bauxite (may contain silica) Table 2-1. Occupational Health Surveillance Charts. Examples of Medical and Industrial Hygiene Considerations in an Aluminum Corporation Principal Use or Source ofEmission Health Effects . Solvent; present in fast drying paints or lacquers Potrooms; materials handling areas; kilns; refractories Spent pot reiinings; cryolite recovery and pot repair; dross reclamation; cleaners; pretreatment of printed packaging Catalyst Irritation of respiratory tract and mucous membranes; narcosis; dermatitis Lung overload; no fibrosis Irritation of respiratory tract and mucous membranes Gastrointestinal and heart disorders; respiratory irritation Medical Surveillance Interval history Interval history Chest x-ray Lung function EKG Chest x-ray Lung function 1977 TLV 1000 ppm 10 mg/m* (1977 addition) 25 ppm 0.5 mg/m* Air Sampling Charcoal tubes Detector tubes Gelman VM-1 membrane filter; nuclepore 0.45 micron filter Detector tubes Impinged in acid Millipore AA filter Insulation; coverings; lagging materials; marinite; molten metal control; brake linings Fibrosis of lung; bronchogenic carcinoma; mesothelioma; cancer of stomach, colon, and rectum Chest x-ray Lung function Sputum cytology (OSHA requirement -- annual medical surveillance) 5 fibers/ml > 5n in length (OSHA standard is 2 fibers/ml > 5/i) MiUipore AA filter (OSHA requirement --semiannual sampling) Materials handling Lung overload Chest x-ray Lung function 10 mg/m* (nuisance dust) Gelman VM-1 filter Respiratory Protection or Other Controls Air-purifying respirator with cartridge for organic vapors Rubber gloves Air-purifying respirator with filter for nuisance dust Air-purifying respirator with cartridge for ammonia Air-purifying respirator with filter for nuisance dust Stibine may be generated under reducing conditions Dependent upon concentration Positive pressure respirator Power filtered respirator Filter respirator Vacuum sweeping Local exhaust ventilation Air-purifying respirator with filter for nuisance dust GLEASON-000059