Document R237XXVLgm7Z3gmDekQpEa7Qz
Airborne Contaminant Acetone
Alumina Ammonia
Antimony PentachJoride
Asbestos
Bauxite (may contain silica)
Table 2-1. Occupational Health Surveillance Charts. Examples of Medical and Industrial Hygiene Considerations in an Aluminum Corporation
Principal Use or Source ofEmission
Health Effects .
Solvent; present in fast drying paints or lacquers
Potrooms; materials handling areas; kilns; refractories
Spent pot reiinings; cryolite recovery and pot repair; dross reclamation; cleaners; pretreatment of printed packaging
Catalyst
Irritation of respiratory tract and mucous membranes; narcosis; dermatitis
Lung overload; no fibrosis
Irritation of respiratory tract and mucous membranes
Gastrointestinal and heart disorders; respiratory irritation
Medical Surveillance Interval history
Interval history
Chest x-ray Lung function
EKG Chest x-ray Lung function
1977 TLV 1000 ppm
10 mg/m* (1977 addition)
25 ppm
0.5 mg/m*
Air Sampling
Charcoal tubes Detector tubes
Gelman VM-1 membrane filter; nuclepore 0.45 micron filter
Detector tubes Impinged in acid
Millipore AA filter
Insulation; coverings; lagging materials;
marinite; molten metal control; brake linings
Fibrosis of lung; bronchogenic carcinoma; mesothelioma; cancer of stomach, colon, and rectum
Chest x-ray Lung function Sputum cytology (OSHA requirement
-- annual medical surveillance)
5 fibers/ml > 5n in length
(OSHA standard is 2 fibers/ml > 5/i)
MiUipore AA filter (OSHA requirement
--semiannual sampling)
Materials handling
Lung overload
Chest x-ray Lung function
10 mg/m* (nuisance dust)
Gelman VM-1 filter
Respiratory Protection or Other
Controls
Air-purifying respirator with cartridge for organic vapors
Rubber gloves
Air-purifying respirator with filter for nuisance dust
Air-purifying respirator with cartridge for ammonia
Air-purifying respirator with filter for nuisance dust
Stibine may be generated under reducing conditions
Dependent upon concentration
Positive pressure respirator
Power filtered respirator
Filter respirator Vacuum sweeping Local exhaust
ventilation Air-purifying
respirator with filter for nuisance dust
GLEASON-000059