Document QrovzLdwQay5Dyag69GNzwRo
Monsanto industrial c
iicals co
rKOM INAME ft LOCATION,
R. H. MUIlCh " TlB
General Offices, St
'0/Jy//,./V%-v. C/? o.X~
DATE November 9, 197 2
suejECT G. E. , PITTSFIELD, MASS.
REFERENCE :
/
TO :Mr. J. G. Bryant #2 Kimbrough Court Talley Farms, Delaware 19810
- cc C. P. P. N.
__ _>J. E. B. W.
Paton - B2SC G. Benignus - B2SH L. Slayton - N.Y. - 1650 T. Johnson/T. L. Gossage R. Savage - B2SL M. Potter - B2NK M. McCutchan - WGK - 1740 R. Richard - T3A
B2S:
We have completed our work on the samples related to the G. E. Pittsfield complaint on Aroclor 1254 shipped to them recently in ACFX 32454. The results are as follows:
1) The pellets removed from the contents of ACFX 32454 were shown to be isotactic polypropylene by infrared absorption spectroscopy. They are agglomerates of very small particles.
2) The plastic rings from an Alsop filter cartridge of the type used to filter the Aroclor 1254 into the tank car were also shown to be isotactic polypropylene by the same method.
3) When pieces of the plastic rings from the filter cartridge
were placed in Aroclor 1254 at 100, 125 and 140C for 48
hours, the fluid remained clear and there was no readily
apparent change in the plastic on visual inspection.
However, when the fluid was allowed to cool, that held at
100C became very slightly turbid, that held at 125C became
quite milky and that at 140C contained a considerable
.
amount of finely divided solid.
4) A differential infrared spectrum using material from the tank car as the sample and a sample of Aroclor 1254 direct from the still as the reference showed no detectable difference between the two. It is estimated that this would have detected 0.02% of dissolved polypropylene.
5) When the two Aroclor 1254 samples were heated nearly to boiling in a test tube and a few drops of 98% sulfuric acid were added, both samples remained colorless. Traces of most foreign organic materials including polypropylene cause discoloration of the sample if they are present.
These results indicate that the "pellets" from the tank car proba bly were formed by solution of some of the polypropylene spacer ring material in the hot fluid as it passed through the filter or more likely some time whiite stagnant fluid remained in the filter. The filter is steam traced and could perhaps have reached tempera tures in the 100 to 140C range when there was no fluid flow. The pellets could result by agglomeration of the finely divided material which came out of solution on cooling during shipment.
|W - IO a E V . 11-65
0* STLCOPCB4076033
Mr. J. G. Bryant November 9, 1972 Page No. 2 The differential infrared data and the sulfuric acid test both indicate that the amount of foreign material in the returned Aroclor 1254 is very small, so small that it could.have no influence on performance of the Aroclor 1254 in a transformer askarel blend.
R. H. Munch
DSW 329326
STLCOPCB4076034