Document QpZ5qJxQGjoEgR8qZw2rBjp7
Air System Equipment ventilators
nrmr i in
utmL-nm| Subject t'a Tfofce (factnot
P. O. Box 47605
Los Angeles 47, Calif.
Multi-Functional Powered Roof Ventilators
MODEL ER {Exhauster and Patent No. 27005S1
Recirculator)
Other patents pending
MODEL BS (Exhauster and Supplier)
MODEL RS (Rectrcu- DELUXE MODEL ERS lator and Supplier) (Exhauster, Recirculator and Supplier) Unit selection table dependent upon roof height CTo be usedwith all models except Power Roof Exhausters)
Mn* Roof Height--To ir 14' 16' 18' 20' 22' Over 22'
Genie-Air Unit Size-- 15 17 19 21 25 31 38
GENIE-AIR Performance Data For All Models
Unit size
15-10 15-14 17-18 17-22
a JLy|jL u
a
1000 1140 1400 1140 1800 1140 2200 1140
O
d J33
JS Oh
H1 hi 1 H1 hi 1
Volt-
115 115 115-230 115-230
DD
DD DD
DD
Weight
PRE ER
70 80 70 80 75 85 75 85
19-27 2700 1140 hi 1 115-230 DD 19-30 3000 1140 H 1 115-230 DD
85 95 85 95
21-33 3300 1140 M 1 115-230 DD 21-37 3750 1140 hi 1 115-230 DD
100 110 100 110
25-41 4100 1140 hi 1 115-230 DD 25-47 4700 1140 M 1 115-230 DD
150 160 150 160
31-55 5500 850 hi 1 115/230 31-55 6500 750 hi 1 115/230 31-80 8000 750 h 115/230
BD BD
BD
260 300 260 3C0 265 305
38-10 10S50 900 hi 3 220/440 BD-DD 310 360
38-13 13000 545 1 3 220/44 BD
315 365
38-14 14400 1140 1 3 220/440 DD 315 365
38-16 16800 1140 1H 3 220/440 DD 320 370
GENIE-AIRS exhaust, recirculate, sup ply or mix recirculated and supply air--
any 1,2,3 or all 4 functions with the same unit. MODEL ER exhausts in summer and re circulates in winter. During the recircu lating cycle the butterfly dampers, which seal the opening between the roof jack collar ana sleeve section, remain in closed position and the heated air trapped at the roof line is recovered through the opening between the venturi and jet and returned to the occupied areaj thus improving the efficiency of the heating system and reducing operating costs as well as initial costs. The cycle of operation may be changed at any time through a three-position switch or ther mostat. In new design the amount of heat normally required can be greatly reduced when used in conjunction with these units. This model, with slight modifications, can also provide for sup ply of fresh air. MODEL ES either exhausts or provides
for supply of fresh air merely by revers ing fan rotation through a three-posi
tion switch. MODEL PRE is a typical power roof ventilator. This unit is equipped with butterfly dampers, which prevent heat
loss in winter. MODEL RS recirculates or supplies: also, any proportion of recirculated and
supply air may be obtained by varying the opening between the venturi and je. thru a manually, pneumatically, or elec trically-operated mechanism. Filters are
optional. DELUXE MODEL ERS provides all four
functions listed above. Filters are op tional. Raise the sleeve or fan section for recirculated or exhaust air and close it for supply. The sleeve or fan section is raised or lowered by: (1) gear ratio motor and rack assembly, controlled
either by a three-position switch or ther mostat or (2) manual mechanism. Tms
model available in sizes 31 and 38 only. NOTE: Cfm delivery of all models has been calculated on the basis of the static pressure through the unit. As the per centage of cfm delivery is reduced when
fan blade rotation is reversed, specify on which cycle of operation the greater cim is required. Units having larger capaci
ties or special combinations of fa blades, motor sizes and speeds are avail
able on special order.
238
Air System Equipment valuator.
Dimensional Data
Dimensional Chari For All Genie-Air Models
Size
CD
DD
WBS
SSD
FSD
"U Diam."
15 16 17 18
19 20 21 22 25 26 31 32 38 39
34 19 16 15 22}* 38 21 17 17 25 38 23 19 19 26 42 25 21 21 28 45 31 25 25 33 54 35 31 31 39 59 44 38 38 48
Dimensions in Inches
Sea charts below for A, B, A SL dimensions.
Models ER. RS, ERS
Models BS and PRE
Type 1 or Type 2 roof jacks, as illustrated below, are furnished with all Genie-Airs.
Any model may be installed in either type of roof jack; however type 2 is preferred
because of its simplicity of installation. In either case, CD dimension plus 3 in.
must be held vertically clear downward through the full length of equipment be
low the underside of roof..Unit sizes 31 and 38 require support in addition to the
roof jack. Support is to be furnished by others. See suggested method for framing
or support.
Type l Roof Jack
Type 2 Roof Jack
TYPE 1 ROOF JACK--*'RO" (roof jack opening-- inside dimensions) for unit sixes 15,17,19, 21 A 25 is
28 in. x 28 in.; size 31 is 36 in.x36 in.;sise 38 is 42 in. x 42 in.
TYPE 2 ROOF JACK--B2 (inside dimensions of roof jack base) for unit sixes 15,17,19,21 and 25 is 31 in. x 31 in.. CH (collar height above base) is 5 in., F2 (finish
surface dimensions of curb including roofing paper) must be 30}* x 30}* in.; B2 for unit sixes 31 & 38 is 43 in. x 43 in., CH is 6 in., F2 must be 42}* in. x 42}* in. All curbs must be 6 in. minimum on high side
The Following Dimensions Are to Be Used With Type 1 Roof Jack:
The Following Dimensions Are to Be Used With Type 2 Roof Jack:
GenieAir
Size
15 17 19 21 25 31 38
Models ER, RS, and ERS
A SL B
27 27 37 29 27 38 29 27 38}* 35 27 39}* 39 27 43}* 42 27 51}* 44 28 52}*
Models PRE Models ES
A B A *B
27 16 27 17 29 16 29 17 29 16 29 17 35 16 35 17 39 17 39 17 42 18 42 17 44 19 44 18
GenieAir
Size
15 17 19 21 25 31 38
Models ER, RS. and ERS
Model PRE
A SL B A B
21 27 43 21 22 23 27 44 23 22
23 27 44W 23 22 29 27 45}* 29 22 33 27 49}* 33 23 36 27 5ZH 36 24 38 28 58}* 38 25
Model ES
A B 21 23 23 23 23 23 29 23 33 24 36 25 38 26
* Dimensions (in inches) Based on 12 in. Roof
* Dimensions (in inches)-Based on 6 in. Curb
Jack Height But May Be Varied.
Height (High Side of Roof) BuVMay Be Varied.
SUGGESTED METHODS FOR FRAMING OR SUPPORTING SIZES:31 & 38
Typical Installation With Steel Frame Support
Typical Installation With
Wood or Steel Prams Support
NOTE: On flat or slightly pitched roofs 14-gauge steel
collar may be connected above roof decking with necessary support framing on underside of roof.
NOTE: Conformance of installations with local agencies and governing codes is the responsibility of others.
SUGGESTED ELECTRICAL SWITCH WIRING USING 3-POLE DOUBLE-THROW SWITCH
(P 1__Ql'
Write for Complete Catalog
239