Document Qkw0OLBwOeKnEZjbxx2Z54zv4

356 CHAPTER 14 Table 9. Approximate Maximum Theoretical COj.Values, and C0t MMf Values for Various Fuels with Different Percentages of j Excess Air '' j;1-- Type op Fuel Maximum -Theoretical, or OJtiV<EtCEKT COxPercent at Given Exc*8s&' Air Values r; v 20% 40% Coke Anthracite Bituminous Coal No. 1 and 2 Fuel Oil 21.0 17.5 15.0 13:0. 20.2 16.8 14.4 12:6 - 18.2 15.1 12.9 11.3 15.0 12.3 10.5 9.1 No. 6 Fuel Oil Natural Gas Carburetted Water Gas Coke Oven Gas ' 16.5 12.1 17.2 11.2 13.6 11.6 10.1 9.9 8.4 7.3 14.2 12.1 10.6 9.2 7.8 6:8 Mixed Gas (Natural and Carbu retted Water Gas) Propane Gas (Commercial) Butane Gas (Commercial) 15.3 13.9 14.1 12.5 10.5 9.1 11.4 9.6 8.4 11.6 9.8 8.5 a heal balance. Various components of this balance are generally expressed in terms of Btu per pound of fuel burned, or as a percentage of its calorific value. Components of special interest are listed as items 1 to 7 inclusive. 1. Useful heat transferred to heating medium, usually computed by determining the rate of flow of the heating fluid through the heating device, and the change in enthalpy of the fluid (heat added) between the inlet and outlet. 2. Heat loss in the dry chimney gases. hi = WjCp (fg -- f.) (12) 3. Heat loss in water vapor formed by.the combustion of hydrogen. hl = T5o (1089 - '*+ 0 455 *') (13> 4. Heat loss in water vapor inthe air supplied for combustion. A, = 0.455 M u>.: ((, - !,) 5. Heat loss from incomplete combustion. * - `"'"(toTJs) 04) "s 6. Heat loss from unburned carbon in the ash or refuse. h5 = 1460*(^-c) 7. Radiation and all other unaccounted for losses. Radiation and convection losses from a heating appliance are not usually detet mined by direct measurement. For this reason they, together with any other loss not measured, are determined by subtracting the total of items 1 to 6 from the he of combustion of the fuel. If the heating appliance is located within the neat space, however, radiation and convection losses may be considered as useful he rather than lost heat. They may, therefore, be omitted from calculations of he A value of 14600 applies in calculating ash pit loss; in calculating heat of formation of carbon comPu use 14093 Btu per lb. Fuels and Combustion 357 losses or added to item 1. If there is CO in the flue gases, small amounts of tinburnecl hydrogen and hydrocarbons will probably also be present. The small loses due to incomplete combustion of these latter gases would also be included in item 7. Symbols used in Equations 12 to 16 inclusive are: A. = heat loss in the dry chimney gases, Btu per pound of fuel. A* = heat loss in water vapor from combustion of hydrogen, Btu per pound of fuel. A, = heat loss in water vapor in combustion air, Btu per pound of fuel, A. = heat loss from incomplete combustion of carbon, Btu per pound of fuel, As = heat loss from unburned carbon in the ash, Btu per pound of fuel. ths = weight of dry flue gas per pound of fuel (from Equation 10), pounds-, hp = mean specific heat of flue gases at constant pressure (c,, ranges from 0.242 to 0.254 for flue gas temperatures from 300 F to 1000 F)1, Btu per pound, ^B = temperature of flue gases at exit of heating device, Fahrenheit, temperature of combustion air, Fahrenheit. = percentage of hydrogen in fuel by weight from ultimate analysis of fuel burned. 1091.8 = enthalpy of saturated water vapor at a temperature of 70 F, Btu per pound. M = humidity ratio of combustion air, pounds of water vapor per pound of dry air. w. = weight of combustion air per pound of fuel used, pounds, from Equations 2, 4, 5, 6, 7 and 8. CO, COs = percentages of CO, COt in flue gases by volume. c = weight of carbon burned per pound of fuel corrected for carbon in ash, pounds. where WC,, - W. 100 W (17) C,, = percentage of carbon in the fuel by weight from the ultimate analysis. H'* = weight of ash and refuse, pounds. C, = percent of combustible in ash by weight (combustible in ash is usually considered to be carbon). IF = weight of fuel used, pounds. th^h6 ^ 'osses fr solid and liquid fuels, listed as items 2, 3 and 4 of the heat balance, may be determined with sufficient precision for most Purposes from curves shown in Fig. 62, if C02 content and temperature of Uf<JaSeS are known- Values of the losses plotted for fuel oil were com puted from the ultimate analysis of a typical fuel oil used in domestic timers, while those presented for the several ranks of coal were computed tn (he typical ultimate analyses shown in Table . 1. The curves for hdium volatile bituminous coal may be used for high volatile bituminous 0 _ "Vh negligible error. Utilization of gaseous fuels, for numerous reasons, is generally a more sim- th 5rcess. (han is the case with either solid or liquid fuels. Accordingly, ^termination of a practical heat balance is also a more simple procedure of t detns 5 and 6 do not generally apply to gas installations. A series in? flP i a^Snmen( charts has been combined in Fig. 7 for use in determin- anc Ue ^ems 2, 3 and 4 from common types of gas burning appli- eof^'tT0 determine flue losses place a straight edge extending from the loss ` temPerature reading to the percent CO2 recorded. Percent flue ls lndicated where the straight edge interesects the flue loss column.