September 29, 1971
Mr. Austin W. West, Jr. Oeneral Production Mgr. Reichhold Chemicals Ino. Tuscaloosa, Ala. 35^01
Dear Mr. West:
The abstract (volume 75 - 1971) referred to in your letter r September 20 describes a treatment for Thertninol PR-1 heat transfer systems to retard the effeot of acidity on the system metallurgy as a result of decomposition of the fluid.
_ The technique will only give satisfactory results with clean system Internals. That Is to say, tha Internal metallurgy 'f the system muat be chemically clean before a satisfactory re sult Is obtained. It has been our experience that the degree of cleaning obtainable In an Installed Thermlnol PR heat transfer system Is not sufficient to successfully employ this technique.
Inasmuch as you have an installed heat transfer system uaing our Thermlnol PR product, I would like to relate our concern over any release of this fluid to the environment. Thermlnol PR-1 contains polychlorinated biphenyls (PCB), a ohemlstry which has been Identified as a persistent pollutant in nature. The PCB concentration in our environment has increasingly come under the sorutlny of various governmental agencies and solentiflo laboratories. In some studies, certain PCBs have been found to be so persistent an environmental oontamlnant that possible Injury to certain forma of bird, aquatic, and animal life oould result. Accordingly, It Is very Important that PCBs be kept out of the food chain.
In light of the concern shown ovsr PCBs we are encouraging all users of the Thermlnol PR series heat transfer fluids which contain PCBs to consider a change to a non-PCB containing Thermlnol suoh aa Thermlnol 55, 66 or 77. While these are not classified as fire resistant fluids, proper design, opera tion and maintenance and the use of appropriate protective de vices would minimise any added fire risk.
DSW 020448
STLCOPCB4008377
2- -
I have attaohed technical data m Thermlnol 55, 66 and 77 fluids. For your speolfic application* I suggest Thermlnol 66 as a possible replacement for the Thermlnol PR fluid now in your system. We encourage your consideration of a change from Thermlnol PR fluid to Thermlnol 66 at this time* as long term availability Is uncertain. We would be happy to discuss details of disposal of Thermlnol PR fluid and appllcation of the Thermlnol 66 fluid.
Please feel free to contact either Carl Clay* our Thermlnol representative in Atlanta* or me in St. Louis. Carl Clay's Atlanta address is 320 Interstate N. Parkway, Suite 500* Atlanta* Oa. (404) 432-7IH.
Very truly yours.
cs Enclosures
D. S. Roush Product Specialist Heat Transfer Fluids