Heating Systems Burners, oa,
The Barber Gas Burner Company
3704 Superior Ave., Cleveland, Ohio
Address Michigan Inquiries to The Barber Gas Burner Co., of Mich., 4475 Cass Ave., Detroit, Mich,
Barber Automatic Jet Gas Conversion Burners, for heating and air conditioning equipment, have a record of high efficiency, for a period of over 20 years, giving con tinuous satisfaction in many thousands of homes and other buildings in United States and Canada. The exclusive Barber Jet principle of combustion, attaining 1900 deg flame temperature on atmospheric pressure, and other basic advantages of design, have given Barber a permanent place in modern heating and air conditioning practice. Barber Burners for gas burning appliances have been adopted as standards by many appliance manufacturers. Shown here are only a few items from Barber's complete line. Illustrated No. 38A Catalog and Price List furnished on request.
Heating Systems Burners. Gas
The Webster Engineering Co.
419 West 2nd St., Tulsa, Oklahoma
Division of SURFACE COMBUSTION CORP., TOLEDO, OHIO
WECO-N.G.E. SERIES F600 GAS BURNERS
50,000 to 10,000,000 Btu Output
No. C. L*90 Burner Unit
Conversion Burners for Furnaces or Boilers
n
Burners are adjustable as to diame ter, on the job, to fit practically all round grate sizes. Also to fit grates of
oblong furnaces and boilers. Listed in the A.G.A. Directory of Approved Ap pliances. Equipped with automatic controls with motor gas valve, with
magnetic gas valve control, with quick acting gas valve control (for buildings equipped with automatic heat control), or in "M" series with manual control.
Barber Burners and Regulators are Adaptable to: Air Conditioning Equipment, High Pressure Boilers (Tubular and Tubeless), Bakery Ovens, Garage Heaters, Coffee Urns, Hair Dryers, Space Heaters, Floor Furnaces, Clothes Dryers, Water Heaters, Confectioners' Stoves, Vulcanizing Machines, Pressing Machine Boilers,
Japanning Ovens, Core Ovens, Banana Room Heaters, Other Appliances.
Gas Burner Specialists offering Engineering Department and Laboratory facilities for Gas Burner problems. Consultation invited.
1014
For Use in Any Steel
The Series F600 venturi tube is 6H* wide, 10H' long, as shown (at right) and the complete assembly is only 15' high. An
infinite number of assemblies are possible by proper arrange ment of the individual tubes. For complete sizing information see Bulletin F600H.
Improved venturi and greater port area insure much higher capacities at lower
pressures. Unique baffles at the outlet of the mixing
tube make possible perfectly even distri bution of flame completely around the baffle brick. As a result the maximum flame length is greatly reduced.
Interchangeable grills with multiple ports can be varied to suit the combustion char acteristics of various gases. The proper sizing of these grills prevents any possi
bility of flash back. In addition to the above major improve
ments the F600 possesses the same desir able features that made the 600 so popular.
1. Simple installation requiring no ex pensive insulated combustion chamber and having no furnace radiation loss.
2. Extreme quietness due to low rate of
combustion over a large area. 3. Flexibility from infinite number of
possible combinations varying both size and shape to meet load and firebox con ditions at various gas pressures.
'4. High radiant transmission rate due to radiant temperature of the standard fire brick baffles on the top of the burner tubes.
5. Low draft loss because of ample secondary air openings.
6. Plain gas pilots of heat resistant material and of a design that will not allow
flame to pull off. 7. Safety pilot applied in a cool zone
in a manner that insures perfect direct ignition of the burner yet allowing the the thermal element to cool quickly upon
flame failure. 8. Guaranteed vibrationless under all
conditions.
CAPACITY OF SINGLE F600 VENTURI TUBE--No. 16 M. T. P. ORIFICE
Manifold Gas Pressure
0.5' w.c.
Input--Cu Ft. 1 hr... 26.5
Output--Sq Ft. St. Rad 8l
Output--Boiler H.P... 0.58
1.0* W.C.
40.5
124
0.89
2.CT W.C.
60.5
185
1.33
3.0" W.C.
75.0
229
1.65
4.0" W.C.
87.0
267
1.91
5.0* W.C.
98.0
301
2.15
6.0* W.C.
108.0
331
2.37
4 oz
116.0 355 2.54
6 oz
143.5 440 3.14
8 oz
166.5 510 3.66
1015