ASHRAB Guide And Data Book
MARSH INSTRUMENT COMPANY
Division of Colorado Oil and Gas Corporation
3501 Howard St., Skokie, 111.
Branch Factories: 1121 RothweD Su> Sect. IS. Houston. Texas; 10372 58 Avenue, Edmonton, Al berta Canada.
Warehouses and Sales Offices: 1209 Anderson Avenue, Fort Lee, New Jersey; 15145 Loraine
Avenue, Cleveland, Ohio; 35 Stoffel Drive, Rexdale Ontario, Canada.
Sales Offices in principal riiin
> Marsh products include: Pressure, Vacuum and Compound Gages; Dial Thermometers; Steam Traps; Vents; Packless Radiator Valves and Radiator Traps; Refrigeration Water Regulators; Refrigeration Testing Instruments; Solenoid Valves; Needle Throttling Valves.
Radiator Traps--Equipped with the famous Marsh phosphor bronze diaphragm charged with voliatile fluid. Extremely rugged, but so sensitive it closes tight on steam and opens instantly to pass
condensate and air at only a few degrees below closing tempera ture. Highly efficient on pressures from below atmospheric up to 25 psi Other traps available for pressures up to 125 psi.
Pressure Gauges and Dial Thermometers--The respected Marsh line covers every requirement for pressure, compound, alti tude gauges, ther-allimeters and dial thermometers. Marsh instru ments are the product of nearly a century of experience. i ranges and case styles for all needs.
Radiator Trap and Pack-
less Valve available in full range of sizes and patterns. Adjustable ori fice valves are availshie.
Packless Radiator Valves--for hot water or steam, maximum water pressure 125 psi. Mechanical seal eliminates packing of any kind. New R-105 scries enables you to adjust orifice with twist of screwdriver to balance either steam or hot water system.
Float and Thermostatic Traps--De signed for complete removal of air and con densate from steam mains, branches and risen. Condensate discharged through float operated.valve at bottom; air through vent in top. Wide range of pressure and capacity ratings. One of the many float and thermo static traps is illustrated. Line also includes Boat traps.
Inverted Bucket Traps--Marsh quality and performance in a trap for applications where the inverted bucket type is indicated.
Marsh Float and Hierinostalic Trap.
Air Vents--Automatically remove air and gasses from tanks, coils or piping, liqnid pump systems, and other similar applica tions. Float holds valve tightly closed when system is filled. Opens only when air accum ulates. Has vacuum check which prevents return of air. Type illustrated is for working pressures up to 12S psi. Other types, includ ing float and thermostatic types, for low
Marsh Inverted Bucket Trap.
Solenoid Valves--in the "Master-mite" line may be had as either direct-acting con duit or grommet types. There are two port sizes: and NPT. Wide range of volt ages: 12, 24, 115, 208, 230 and 460 V, a-c. Pressures from vacuum to 540 psi. Orifice
vary. Type 16 offers four: 3/64** through 3/32*. Type 26 has ten: 3/64* through Type 36 has eight body orifices, 3/64* through 5/32* and four top orifices, 3/64* through 3/32*. Many are Underwrit ers* approved as safety valve. Other Marsh solenoids, both direct-acting and pilot-oper ated, cover wide range of needs.
Marsh No. 50 Air Vent
"Master-mite" Solenoid Valve
Conduit type
Refrigeration Valves--Type 56 pressureactuated regulating valves shown here are adjustable for both Refrigerant 12 and 22-- from 60 to 270 psi. Though compact, they have ample capacity for wide range of ap plications. Other Marsh water regulating valves are both temperature and pressure, actuated.
Piping and Duct Thermometers--For piping, air ducts, vessels, kilos, ovens, etc. Unbreakable with greater reading accuracy than glass tube thermometers. Line of 4 types, 7 ranges, 72 combinations. Big, legi ble 3%* and 4%* dials easily tilted or tamed to best reading angle. Specify di rect mount or distant reading. Separable sockets for easy installation. Extension necks for insulated piping or ducts. Long stems in duct* types put temperature-sensi tive section where it most be for accurate indication.
Type 56 Water Regulator
Marsh Piping Thermometer
Bimetal Thermometers--Marsh Master Therm Bimetals are accurate to 1% of range. Available with Conoweld, Rad-Easy dial and Recalibrator. Back or bottom con nection. Seamless steel stems 2%*, 4*, 6*, 9*. 12*, 15*. 18* and 24*. Dial sizes 2*, 3*. 5* or 6%*. Adj'ostable Master Therms with SVs" or 6H' dials only. Ranges from 0-250" F. to 200*-1000* F.
Master Therm Bi metal Thermom eter, Back Con
nection
FOR FURTHER INFORMATION. WRITE FOR MARSH CATAI4TG C-100
Cataiot Data Section
Kmiimm DEPT. AG-21. NORTHVALE. NEW JERSEY
33
PACKAGED AUTOMATIC GAS HEATING PLANTS Providing Space or Volume Water Heating
for Residential, Commercial and Industrial Uses
<5,000 BTU/hr to 3,600,000 BTU/hr INPUT RATINGS
HWQJhFrm
HTDROTHERM boilers arc of all cast
iron construction and arc exclusively
designed for gas. The patented ab
sorption unit, composed of deep-rib
horizontal sections connected in zigzag,
permits maximum heat transfer in min
imum space with small water content,
M*ai n-in
vita HumM afcth Jacket: 4M lb*. *' X SI' X 38V4'
This "true" gas design results in low fuel consumption, quick heat response, uniform heat transfer, self cleaning
flue passages, and smalt installation space. HyDROTHERM boil
ers are A-G-A.-a p proved for ad gases and are factory assembled
and wired with the finest safety and gas controls, ready for quick
installation. Boiler and controls are enclosed in an attractively
finished insulated steel jacket
MULTI-TEMP, a new con
cept in heavy duty gas-fired
hot water heating, provides
any desired capacity with a
. multiple of HyDROTHERM
units, each equipped with its
own controls. True input modulation is accomplished
oScj r'swSisos tb*. 85" x 32'x V
by having the separate boiler units fired or cut out in response to a special
Minneapolis Honeywell electronic step-control. This control receives its
signal from indoor-outdoor resistance bulbs. If the temperature in the
supply header exceeds the desired setting, it simply steps back until the
signals received from outside and inside are in balance. In leu critical
installations, boiler units can be controlled by aquestats with different
settings in the return manifold.
AH boilers are tested at 250# hydrostatic pressure and carry a 100# ASME rating which permits direct connection of boilers to" city water lines as required for volume water heating applications.
MULTI-TEMP, being' composed of multiple units, ofTcn extra protection against service interruption. Each boiler unit ts shipped completely as sembled to simplify field installation.
CAPACITY RANGE OF HYDROTHERM BOILERS
OTHER
SPACE HEATING A.G.A. RATINGS
VOLUME WATER HEATING GALLONS PER/HOUR FOR TEMP. RISE SHOWN
A.GJU Approved as Central Heating Boilers
Natural, Mixed and Manufactured Cat
UP. Gar (Propone)
Natural, Mixed eed Mo--factored Gar
UP. Cat (Propane)
Nat Net
%bpwt Outpet LBJL ED*
Oatpat IJJ. ED8
Modal No.
1000 6TU/
1000 BTU/
*1000
Sq. Ft. but.
BTU/
1000 BTU/
*1000
Sq.Pt. hut.
80*
too* 120" 140" 80*
100* 120" 140"
hr. hr.
Bad. hr. hr. BTU/ tad.
hr.**
HC-6S
65 52 39 260 60 48 36 240 80
63 52 44 74 57 48 40
Hc-as
85 68 51 340 77 62 46 306 102 81 66 58 94 75 61 52
HC-100 100 80 60 400 100 80 60
400 120 96 80 69 120 96
80 69
HC-125 125 100 75 500 125 100 75 500 150 120 100 86 150 120 100 86
MC-145 145 1 16 87 580 145 116 87 580 174 139 116 100 174 139 116 100
R-125 8-155 8-180 1-210 I 8-250 8-300
125 100 75 500 120 96 72
480 150 120 100 86 144 IIS
96 82
155 124 93 620 155 124 93 620 186 149 124 106 186 149 124 106
180 144 108 720 180 144 108 720 215 173 145 124 215 173 145 124
210 160 126 840 210 168 126
840 255 202 169 145 2SS 202 169 145
250 200 ISO 1,000 250 200 150 1,980 300 240 200 173 300 240 200 173
300 240 180 1,200 290 232 174 1,160 360 288 240 206 348 276 232 198
*-360
MlSit
8-420 8-500
8-600
5
8-750 8-900
360 286 216 t,440 360 288 216 1/40 430 350 290 250 430 350 290 250 420 336 252 1,680 420 336 252 1/80 510 410 340 290 510 400 340 290 500 400 300 2,000 500 400 300 2,000 600 480 400 340 600 480 400 340 600 480 360 2,400 580 464 348 2/20 720 580 480 410 700 560 470 400 750 600 450 3,000 750 600 450 3,000 900 720 600 520 910 720 600 520 900 720 540 3,600 870 696 522 3,480 1060 870 720 620 1050 640 700 600
8-1000
8-1200
8-1500
S|*
8-1 BOO 8-2100
il* 8-2400 8-2700
8-3000
8-3300
8-3600
1.000 1,200 M00 1,800 2.100 2,400 2,700
3,000 3,300 3.600
800 960 1,200 1,4J 1,680 1,920 2,160 2,400 2.640 2,808
600 4.000 1/100 720 4,800 1,160 900 6.000 1/50 1,095 7,300 1750 1,295 8.635 2,030 1,489 9,930 2,320 1,677 11,180 2,610
1,863 12,425 2.900 2/49 13,665 3,190 2,236 14,905 3,480
800 928 1,160 1,392 1,624 1,656 2,088 2,320 2,552 2784
600
696 870 1,054 1,348 1,438 1/21 1,601 1,981
2,161
4/00 4/40
5,800 7/20 8/20 9/90 10,805 12/10 13/10 14/10
1210 1450
1810 2170 2530 2890 3250 3610 3980 4340
960 1160
1450 1740 2020 2310 2600 2890 3180 3470
800 960 1210 1450 1690 1930 2170 2410 2650 2890
OOOOOOOOOO
1200 960 1400 1120 1750 1400 2100 1680 2450 1960 2800 2240 3140 2520 3490 2800 3840 3070 4190 3350
800 930
1160 1400 1630 I860 2100 2330 2560 2800
690 800 1000 1200 1400 1600 1800 2000 2200 2400
** Tbee rsdtgi or* bawd on piping and pickup factor? eaobfehed by 'The fadMi l Bollor Moadsdom* Wbaa piping fas** am iwgtgUi) nwper nay ba Incraatad 12%, ei In penal aid ba--board heating, ate
Melli-Tcmp Water Heaters
Duo-Service System
P-Type Package
Boiler)