III.
Fart IV controlling demolition remains unchanged except
for a rewording of the requirement for enclosure'. The final
proposal is intended to require an enclosure only when necessary
to prevent dispersion of dust and only an enclosure which is
reasonably compatible with the structure to be demolished. In
some cases total enclosure can be feasibly achieved. With other
structures, a ground level enclosure may be the limit of com
patibility.
IV. Part V, controlling manufacturing sources, is changed to re
quire an emission standard of 2 fibers per cubic centimeter and no visible emissions. While some testimony indicated the difficulty in measuring compliance with a numerical emission standard, over all the evidence establishes both the need (protection against the great proportion of invisible fiber) and the ease of measurement of such a criterion. A "no visible emission" standard has been added to the numerical standard to simplify erfforcement against exceptionally dirty emission sources. A grace period, until June 30, 1972, has been added to permit acquisition of the necessary control equipment to attain the emission standard.
References are made to th method to be used in collecting and counting emission samples. The sampling method is that generally used in sampling particulate emissions. The counting method is that
reliably used by tra U.S. Public Health Service-
A requirement has been added, at the Environmental Protec tion Agency's suggestion, to channel all asbestos emissions inside the plant through control equipment and to exhaust such emissions
through points where samples can be taken. This is intended to prevent venting through windows or doors or other avenues of escape on which sampling cannot be adequately performed. The Agency is also given the power to inspect manufacturing premises at reasonable times to determine compliance. Also, the manufacturer must engage in monitoring and reporting. The latter two additions are in keeping with the Board's practice in most areas of regulation.
The waste water discharge provision now requires no dis charge of process water to which the manufacturer has added asbestos unless best available treatment technology is first utilized.
A "no visible emission" standard has been added to the t
transportation regulation.
The original proposal to ban asbestos brake lining has been dropped for the time being. While the evidence shows that brake lining decomposition ..is a significant source of back ground levels of asbestos, these ambient air levels are quite small and have not been shown to be a health hazard (although they have not been show!', not to be) . In addition adequate alternatives to asbestos-lined brakes are not yet available, although closed