Document Qj3jMYd98jG40Vdj4v4nJzb4
SJi&I Johns-Manviile
Internal Correspondence
To: W. G. Burnett - Denison s
s
From:
Copies:
D. ^Christensen 1-06
T. M. FaasW. E. Volwiler R. C. Cordova
3-07 3-07 R-24
Subject: ANNUAL INDUSTRIAL HYGIENE SURVEY REPORT - DENISON PLANT PIPE DIVISION - WEEK OF OCTOBER 18, 19 82
The annual industrial hygiene survey results of the Denison
plant are enclosed. The survey was conducted during the
week of October 18, 1982 and included monitoring and
analysis for the following hazards:
.
DUST - Asbestos fiber, respirable and total quartz, and
nuisance dust
NOISE
'
FUME/VAPOR
RADIATION - Ionizing and non-ionizing
.
DUST.
There are presently 68 dust stations established at Denison. Of that total, 59 stations were sampled and 9 stations .are listed as DNO (Did Not Operate). Only one of the sampled dust stations, the Injection Molder Mixer Operator, exceeded ther TLV for total quartz."
Industrial hygiene dust stations indicating a "greater
than" (>) TLV have been analyzed for the presence of
crystalline silica and found to have a small but
unquantifiable amount present. Establishment of a precise
TLV requires knowledge relative to the percentage of
crystalline silica present in the sample. Due to the
unquantifiable nature of the data, being generated a precise
TLV cannot be calculated; however, use of the smallest
quantifiable amount for the methods does enable calculation
of the lowest TLV that could exist given the sample
conditions.
'.
The remainder of the dust section will include a discussion of each station listed on the summary page.
JUL O 8 1983
OOA-928
0
W. G. Burnett - Denison December 13, 1982 Page 2
D-2IM Personal - Mixer Operator The sample result for the mixer operator exceeded the TLV for total .quartz. This was unexpected since both ventilation and housekeeping have been improved over the
past six months, according to plant personnel. We recommend that the operator's work practices be reviewed by his supervi-sor and "that the use of respiratory protection be continued.
D-16F Personal - #2 UCL Operator
.
D-26F Personal - *1 UCL Operator
.
Both stations are listed to emphasize a positive
_
environmental control measure taken by the plant that was
initiated by the two operators.. The overhead fans used to
be positioned in such a way that the operators were getting
the dust from the machining operation blown into their work
areas. The fans have now been repositioned so the dust is
not blown into their areas.
.
D-1.TF. Personal - Borino Mill Operator
During the exit meeting, it was mentioned that this piece
of equipment will be taken out of the building and replaced
with a dual purpose piece of equipment from the Stockton
plant. As we have done in the past, stations will continue
to be listed on the permanent stations list until the
equipment is physically removed.
..
D7WE Personal - Willow Feed Operator
This operator was sampled to determine .his occupational
exposure to asbestos and respirable quartz. The sample
results were below their respective TLVs. However, the
first sample result for asbestos fiber-was 1.2 f/cc. This
is twice as high as the 0.6 f/cc reading from September of
1981; a significant increase and a basis to examine the
operator's work practices.
`
At times during the week it was noted that the carouselwhere the fiber is stored prior to dumping had varying amounts of loose fiber from an occasional torn or broken bag. The spills should be vacuumed up and the bags repaired as quickly as possible to prevent further contamination of the area involved.
Although the operator was wearing a respirator, he was observed several times wearing it incorrectly, with only one strap in place. This operator must' be instructed in the correct way to wear a respirator and the supervisor
must provide the necessary enforcement .of the policy.
D 004929
W. G. Burnett - Denison December 13, 1982 Page 3
D-11WE - Area - 13* Line Flow Trough
D-12WE - Area - 10* Line Flow Trough
Both of the above area stations were monitored for asbestos
fiber. The individual sample results seen this survey are
lower than the 1981 levels and about the same as the semi
annual survey of this year. The improvements to the feed
system note-d in J. A. Lawrence's letter of December 2, 1981
have been .completed. The subsequent fiber counts show a
reduction from previous levels, but are still high when
compared to other levels in the plant.
'
The catwalks where the samples are taken are not normally
ioperator stations, but when an individual is required to
*work on the flow trougEs we recommend that he or she wear
approved respiratory' protection.
1"
--i. --i
"
ll,w
-
D-10S Personal - Dempster Dumpster Driver
This station is listed because the job has been expanded
to include feeding scrap pipe and pipe pieces into the
crusher located outside the wet-end section.
The fiber levels seen this survey are a little higher than
on the two previous surveys and are probably attributable
to the expanded duties. The operator was .observed wearing
respiratory protection while feeding the crusher. This
practice should be continued.
'
'
ASBESTOS COLLECTORS
..
All asbestos baghouses were checked for visible emissions
and found to be clear. The baghouse stations a-re included
with the area dust stations in the summary and are found in
the all stations report at the beginning of the`dust
section.
.
K0.I.SH
'
Forty-two of 47 noise stations were monitored at Denison this survey. Of that total, 32 stations exceeded the noise standard of 90 dBA, The noise at these stations remains fairly constant from survey to survey. Therefore, we have not listed them on the summary as requiring your attention. The continued enforcement of your hearing conservation
program is satisfactory until engineering controls are implemented that will effectively reduce the present noise levels.
D 004930
W. G. Burnett - Denison
December 13, 1982 Page 4
The results are listed as equivalent noise levels (Leg).
This figure is expressed in dBA and respresents a time-
weighted average (TWA) sound pressure level over an eight
hour period. Operators that exceed the 90 dBA standard are
required to wear hearing protection.
Because hearing protection is required at the Denison operation you are also in compliance with the new Hearing Conservation Amendment which states that hearing protectors must be made available to all employees exposed to a TWA~ sound level of 85 dBA or greater. However, the amendment does not make their use mandatory until a TWA noise exposure of 90 dBA is exceeded.
FUME/VAPOR
The number of stations required to adequately evaluate
vinyl chloride monomer exposures in the plastic pipe
department has been reassessed. This was done in light of
the historically low concentrations found at all stations
and the minimal amount of residual VCM present in the resin
being received. As a result we have reduced the VCM .
stations to six, and the total number of fume/vapor
stations to 40.
'
Of the 40 established fume/vapor stations, 34 were sampled
and none exceeded the allowable TLV for the particular fume
sampled. Six stations are. listed as DNOs bn the report
and two stations, discussed below, have been listed on the
summary sheet.
.
V-1F Personal - solvent Welding
This station was sampled for 7 different organics and all
were below applicable limits. The fabrication of the
`
Perma-Loc sewer fittings has been moved to the solvent
welding area from the back building. Though the survey
results are below allowable limits, we feel that the
.
existing ventilation system is not adequate to cover the
expanded operation. The strong odors which have led to
several employee complaints best illustrate the need for
improvement. If this is to be the permanent location for
this operation, adequate ventilation must be provided.
Until such time, we recommend that all personnel working in
the solvent welding area wear approved organic vapor
respirators.
D 004931
W. G. Burnett - Denison
December 13, 1982 Page 5
V-1P5 Personal - Filament Winder Operator
This station was also sampled for seven different organics
and all were below allowable standards. The concern here
is the methylene chloride used by the operators to clean
gloves and tools. The methylkene chloride is contained in
two open five-gallon pails that sit on either side of the
machine. The TWA for both samples i^ below the 500 ppm
TLV, but the first sample was 873.6 ppm.
.
Our latest information from plant personnel indicates that a job order was submitted to install a hood over each bucket. As of this survey, the pails remain unventilated. Every effort should be made to expedite the installation of
the ventilation hoods.
RADIATION (NON-IONIZING)
All of the microwaves in the plant were tested during the course of the survey. Minimal emissions were observed at each oven, with none.approaching the 10 mw/cm TLV.
RAPJ&.T-I0N (IONIZING)
'
The medical department1s. x-ray unit and the nurse's exposure record were audited and found to be in order.
As a reminder, the all stations report is to be posted alongside the plant layout*of station locations.
Please respond within 30 days upon receipt of this report and indicate what actions have been taken regarding the stations that were discussed throughout this report. We are particularly interested in your comments relative to stations D-7WE, D-11WE, D-WE, V-1F, and. V-2PS.
D 004932