Width In. | Length (Heater Casing Pius Blower Casing) Height Overall In. No. of Filters | Size Gas Connection Required Air Conditioning Automatic Equipment Heating Systems The Waterman-Waterbury Co. Minneapolis 13, Minnesota Manufacturers of WATERBURY Coal, Oil and Gas Fired Furnaces and Air Conditioning Equipment WATERBURY GAS-TITE FURNACE 700 Series The welded steel furnace body keeps dust, smoke and fumes out of the air stream. A large combustion chamber and radiator with long fire travel insure efficiency and economy. Also furnished in a complete home Air Conditioner. Diameter Height Size Furnace Furnace Body Pip Casing Furnace Body & Hood 720 20' 39* 49 64' 722 22' 41' 49* 64' 724 24' 44' 49* 64' 727 27' 46.' 55' 70* Steel Thickness Body Head Radiator Diam. Smoke Pipe Approx. Shipping Furnace less Casing Output Ratings Sq In. Leader Pipe Btu at Bonnet 10 Ga. lOGa. 7 Ga. 7 Ga. 10 Ga. 7 Ga. 7 Ga. %' 12 Ga. 12 Ga. 12 Ca. 12 Ga. 8' 8' 9 9* 531 482 87329 603 505 91,730 730 541 98.056 866 672 121.856 . Gastite Air Conditioner Length Height 1 c Size & Size Size Outlet Inlet. Opening Opening No. of' Fil ters Size. thru Unit Filter Btu Blower Per Hour CfmRange Output at Bonnet 720-10 36* W 55' 32x24 32x16 2 16x16 375 to 1050 87.963 722*10 40' 56' 55' 36x26 36x22 2 20x20 375 to 1050 94.011 724*10 40* 56' 55' 36x26 36x22 2 20x20 375 to 1050 100.193 724-12 40' 56' 55' 36x26 36x22 2 20x20 645 to 1677 100.193 WATERBURY GAS FIRED AIR CONDITIONER The latest achievement of Waterbury's engineers, designed specifically for gas. Completely automatic--filtered, humidified forced air--enclosed in a compact, baked enamel casing. Can also be furnished for Propane or Butane. Output Input Capacity Blower Size Rating Btu per Cfra Btu hour at Range per Hr Register Size Outlet Opening Size Return Inlet Opening Size each Filter Rec Flue pip* Diam. 6413-9 90.000 72.000 400 to 800 28 50 20x24 15 x24 6413-9 High 90.000 72.000 400 to 800 28 28 64 24x24 6415*10 120.000 96.000 600 to 1200 28 58 20x24 16 x24 6426*12 6426*15 6430-15 6430*18 180,000 144.000 800 to 1600 55 52 50 24x51 19Vsx26 180.000 144.000 1000 to 2800 55 56 50 24x51 25V6x34% 240.000 192.000 1000 to 2800 55 56 58 24x51 25i&iVi 240,000 192.000 1232 to 3204 55 72 58 24x51 40 x36 WATERBURY GAS GRAVITY FURNACE 2 16x25 1 16x25 2 16x25 1 20x25 4 16x20 4 16x20 6 16x25 Size Furnace 6413 6415 6426 6430 Input Rating Btu per Hr 90.000 120.000 180.000 240.000 Output Rating Sq Width In. Warm In. Air Pipe 67300 90.000 135.000 180.000 28 30 28 30 Length In. Height Overall In. Size Outlet Opening ~Rec. Flue Bp. Size Gas Connection Required 28 50 24x24 y 30 58 26x26 6' y.-/.* 55 50 24x51 2-5 to 7' 1' 58 58 26x54 2-6 to S' i/.* 5' 5' 6' 2-5 to 7' 2-5 to 7' 2-6 to 8' 2-6 to 8' %* Yf' %* |* 1' w w 976 Air Conditioning Automatic Equipment Heating Systems The Waterman-Waterbury Co. Mmnnesota 13, WATERBURY 6300 Series OIL FIRED AIR CONDITIONER Completely automatic oil heat with forced, filtered, humidified air, all enclosed in one compact casing finished in baked enamel. Input Rating Gal Oil per Hr Output Capacity Btu per Hr at Bonnet Width 1 Casing : Height i Overall || Size Outlet i Opening SizeReturn II Inlet | 1 Opening |] Distance between Opening No. of . H Filters I Size c&.E JU W-6315-10 1 gal 97.000 28' 58' 58' 24x20 24x16 3' 2320-12 OIL FIRED AIR CONDITIONER This unit has a side mounted burner and can be furnished with a burner hood at slight additional cost. . Vh t.o8up. iii Qtofl. 2 16x25 7' Input Rating Gal Oil per Hr Output Capacity Btu per H r at Register Width Not Inch II Burner Hood || Length || 1Height Overall f Distance between Openings No, of Filters | Diam. Smoke II Pipe || Depth Size 2320-12 1.20 120,000 30 Size Outlet Open ing Size Return Inlet Open ing 60 61 26x24Vs 26x24,/n w 2 Size Each Filter f 1-16x25) \ 1-20x25 f Dimens. Burner Hood Wdt. (Side- Side) BO X 7' 23 17 28 SEAMLESS OIL FIRED FURNACE BODY Specially engineered for oil firing only, it may be used as a gravity circulating pipe furnace. It is the heating element of the Comfortrol Oil Fired Air Conditioners. Specifications Comfortrol Oil Fired Air Conditioners Size Input Rating Gal per Hr Btu per Hr at Register Norma] Cfm Range Width Less Front Hood Length Overall Height Size Outlet Size Inlet 1322-12 1.5 142,763 645 to 1677 44' 72* 64' 36x36 195/5x26 1322-15 1.5 142.763 922 to 2397 44' 74' 64' 36x36 25&x34& 1324-15 1324-18 2.0 2.0 190.350 922 to 2397 48' 190350 1232 to 3204 48' 78' 81' 64' 40x40 25hex34% 64' 40x40 40 x36 1327-18 23 237.938 1232 to 3204 52* 85' 64' 44x44 40 x36 1327-21 23 237,938 1450 to 3770 52' 85' 64' 44x44 38 x44 1330-21 3.0 285325 1450 to 3770 56' 89* 70* 48x48 38 x44 1333-24 33 333.113 1966 to 5118 60* 104' 77? 52x52 46 x48 1336-24 4.0 380.700 1968 to 5118 66' no* 81' 58x58 46 x48 IBuraer hood all sizes is 24 in. wide. 10 in. deep. Add 140 lbs for oil burner and controls. Add 80 lbs for burner hood. Filters No. Size Smoke Pipe {j 20x25 8 16x25 4 16x20 8 4 16x20 8 4 20x25 6 4 20x25 9 6 16x25 9 6 16x25 9 6 20x25 9 6 20x25 9 GAS CONVERSION BURNER A real gas burner, the same as used in the Gas-Air Conditioner. Can also be furnished for Propane or Butane. Number Maximum Btu Input C-100 165.000 Maximum Cubic Feet of Mixed Gas 208 Maximum Cubic Feet of Manuf'd. Gas Minimum Fire Pot Size 300 18 Inch 977