Document Qgwg1Q5y19boZ9qp8QqjgYJak
Width In. |
Length (Heater Casing Pius Blower Casing) Height Overall In. No. of Filters | Size Gas Connection Required
Air Conditioning
Automatic Equipment Heating Systems
The Waterman-Waterbury Co.
Minneapolis 13, Minnesota
Manufacturers of WATERBURY Coal, Oil and Gas Fired Furnaces and Air Conditioning Equipment
WATERBURY GAS-TITE FURNACE 700 Series
The welded steel furnace body keeps dust, smoke and fumes out of the air stream. A large combustion chamber and radiator with long fire travel insure efficiency and economy.
Also furnished in a complete home Air Conditioner.
Diameter
Height
Size Furnace
Furnace Body
Pip Casing
Furnace Body
& Hood
720 20' 39* 49 64' 722 22' 41' 49* 64' 724 24' 44' 49* 64' 727 27' 46.' 55' 70*
Steel Thickness
Body
Head Radiator
Diam.
Smoke Pipe
Approx. Shipping
Furnace less
Casing
Output Ratings
Sq In. Leader
Pipe
Btu
at Bonnet
10 Ga. lOGa.
7 Ga.
7 Ga.
10 Ga. 7 Ga. 7 Ga.
%'
12 Ga.
12 Ga. 12 Ca.
12 Ga.
8' 8'
9
9*
531 482 87329 603 505 91,730 730 541 98.056 866 672 121.856 .
Gastite Air Conditioner
Length Height 1
c
Size &
Size Size Outlet Inlet. Opening Opening
No.
of' Fil ters
Size. thru Unit Filter
Btu
Blower Per Hour CfmRange Output at
Bonnet
720-10 36* W 55' 32x24 32x16 2 16x16 375 to 1050 87.963 722*10 40' 56' 55' 36x26 36x22 2 20x20 375 to 1050 94.011 724*10 40* 56' 55' 36x26 36x22 2 20x20 375 to 1050 100.193 724-12 40' 56' 55' 36x26 36x22 2 20x20 645 to 1677 100.193
WATERBURY GAS FIRED AIR CONDITIONER
The latest achievement of Waterbury's engineers, designed specifically for gas. Completely automatic--filtered, humidified forced air--enclosed in a compact, baked enamel casing. Can also be furnished for Propane or Butane.
Output
Input Capacity Blower
Size Rating Btu per
Cfra
Btu hour at Range
per Hr Register
Size Outlet Opening
Size Return
Inlet Opening
Size each
Filter
Rec Flue
pip* Diam.
6413-9
90.000 72.000 400 to 800 28
50 20x24 15 x24
6413-9 High 90.000 72.000 400 to 800 28 28 64 24x24
6415*10
120.000 96.000 600 to 1200 28
58 20x24 16 x24
6426*12 6426*15
6430-15 6430*18
180,000 144.000 800 to 1600 55 52 50 24x51 19Vsx26 180.000 144.000 1000 to 2800 55 56 50 24x51 25V6x34% 240.000 192.000 1000 to 2800 55 56 58 24x51 25i&iVi 240,000 192.000 1232 to 3204 55 72 58 24x51 40 x36
WATERBURY GAS GRAVITY FURNACE
2 16x25 1 16x25 2 16x25
1 20x25 4 16x20 4 16x20 6 16x25
Size Furnace
6413 6415 6426 6430
Input Rating
Btu per Hr
90.000 120.000 180.000 240.000
Output Rating Sq Width In. Warm In.
Air Pipe
67300
90.000
135.000 180.000
28
30 28
30
Length In.
Height
Overall In.
Size Outlet
Opening
~Rec. Flue Bp.
Size Gas Connection
Required
28 50 24x24 y
30 58 26x26 6'
y.-/.*
55 50 24x51 2-5 to 7' 1'
58 58 26x54 2-6 to S' i/.*
5' 5' 6'
2-5 to 7' 2-5 to 7' 2-6 to 8' 2-6 to 8'
%* Yf' %*
|* 1' w w
976
Air Conditioning
Automatic Equipment Heating Systems
The Waterman-Waterbury Co. Mmnnesota 13,
WATERBURY 6300 Series OIL FIRED AIR CONDITIONER
Completely automatic oil heat with forced, filtered, humidified air, all enclosed in one compact casing finished in baked enamel.
Input Rating Gal Oil per Hr Output Capacity Btu per Hr at Bonnet Width
1
Casing : Height i Overall || Size Outlet i Opening SizeReturn II
Inlet |
1
Opening |] Distance between Opening No. of . H Filters I
Size c&.E JU
W-6315-10 1 gal 97.000 28' 58' 58' 24x20 24x16 3'
2320-12 OIL FIRED AIR CONDITIONER This unit has a side mounted burner and can be furnished with a burner hood at slight additional cost.
.
Vh
t.o8up.
iii Qtofl.
2 16x25 7'
Input Rating Gal Oil per Hr Output Capacity Btu per H r at Register Width Not Inch II Burner Hood || Length || 1Height Overall f Distance between Openings No, of Filters | Diam. Smoke II Pipe || Depth
Size 2320-12
1.20 120,000 30
Size Outlet
Open ing
Size Return
Inlet Open
ing
60 61 26x24Vs 26x24,/n w 2
Size Each Filter
f 1-16x25) \ 1-20x25 f
Dimens.
Burner Hood
Wdt. (Side-
Side)
BO
X
7' 23 17 28
SEAMLESS OIL FIRED FURNACE BODY
Specially engineered for oil firing only, it may be used as a gravity circulating pipe furnace. It is the heating element of the Comfortrol Oil Fired Air Conditioners.
Specifications Comfortrol Oil Fired Air Conditioners
Size
Input
Rating Gal per
Hr
Btu per Hr at
Register
Norma] Cfm Range
Width Less
Front
Hood
Length Overall
Height
Size Outlet
Size Inlet
1322-12 1.5 142,763 645 to 1677 44' 72* 64' 36x36 195/5x26
1322-15 1.5 142.763 922 to 2397 44' 74' 64' 36x36 25&x34&
1324-15 1324-18
2.0 2.0
190.350 922 to 2397 48' 190350 1232 to 3204 48'
78' 81'
64' 40x40 25hex34% 64' 40x40 40 x36
1327-18 23 237.938 1232 to 3204 52* 85' 64' 44x44 40 x36
1327-21 23 237,938 1450 to 3770 52' 85' 64' 44x44 38 x44
1330-21 3.0 285325 1450 to 3770 56' 89* 70* 48x48 38 x44
1333-24 33 333.113 1966 to 5118 60* 104' 77? 52x52 46 x48
1336-24 4.0 380.700 1968 to 5118 66' no* 81' 58x58 46 x48
IBuraer hood all sizes is 24 in. wide. 10 in. deep. Add 140 lbs for oil burner and controls. Add 80 lbs for burner hood.
Filters No. Size
Smoke Pipe
{j 20x25 8 16x25
4 16x20 8 4 16x20 8 4 20x25 6
4 20x25 9 6 16x25 9 6 16x25 9 6 20x25 9 6 20x25 9
GAS CONVERSION BURNER
A real gas burner, the same as used in the Gas-Air Conditioner. Can also be furnished for Propane or Butane.
Number Maximum Btu Input
C-100
165.000
Maximum Cubic Feet of
Mixed Gas
208
Maximum Cubic Feet of Manuf'd. Gas
Minimum Fire Pot Size
300 18 Inch
977