Document Qgq8gdLVKxEwYGVoRKK0DQ7mE
Interoffice Communication
To G. A. O'Brien
From
R. H. Gerlach
Dat* July 12, 1974
Subject
VCM Ship Loading Data
(CQi ICO)
Attached are two reports by Paul Fetzer summarizing the results of the ambient air sampling conducted during the loading of the Hoegh Shield on June 13, 14 and 15 and the Irene on June 21, 22 and 23.
Heel and finished cargo sampling still are the main problem areas, and we are continuing to try to tighten up the system. The dock vent recovery unit was not operated during the Irene loading. The ship's refrigeration unit and vent were used instead. We have contacted the ship owners and re quested that piping modifications be made to their ships which will permit operation of their vent recovery in series with ours.
R. H. Gerlach
is Enc CC + enc: REL-LNV-DVP
OCR 000082185
Ccopoco)
Interoffice Communication
To R. H. Gerlach
From
P. L. Fetzer
Date July 3, 1974
subject
Ship Loading Data - Irene - June 21, 22, and 23, 1974
The Intensive sampling program used on the two previous ships. Alpha Gas and Hoegh Shield, was reduced. Only one Century instrument was used to gather data throughout the loading. Charcoal dosimeter data was obtained for each operational step throughout the loading sequence. Three partial downwind grids were taken during the loading operation. This program re quired two men per 12-hour shift instead of four and does not sacrifice any pertinent information. On future ship loadings I would recommend this re duced sampling operation for monitoring purposes.
All the analytical data pertaining to the loading of the Irene are shown in the attached tables.
The main source of vinyl emission during the loading operation, excluding the vent stack, appears to be during sampling. Five additional 2-liter sample cylinders have been ordered with a 2-week delivery. Additional valves have been ordered to replace those on the one liter sample cylinders. These items should be available for the next ship loading around July 15.
etzer
Is tnc
CCR 000082186
SUMMARY OF RESULTS
i
Ireme Loading - June 22
Loading Line Flange Removal:
23
Heel Samples:
Hydroquinone Addition:
Ship Loadings:
Finish Cargo Sampling:
Century reading went to 50 ppm momentarily then dropped to background reading of 7. The personnel data from the charcoal dosimeter only showed 3.03 ppm TWA for 0.20 hr.
Century readings were high, up to 1,000 ppm. Sample cylinders had leaking valves and the eductor system was again back pressured. To obtain the heel samples, the loading was shut down. The sampling system also leaked badly. The charcoal dosimeter result for the operation was 69.1 ppm VCM.
No change from the background reading on the Century instrument was observed during the hydroquinone addition operation. However, a 10" valve at the hydroquinone station leaked very badly around the packing which was pulled down tight. The charcoal dosimeter result showed 10.7 ppm VCM during the entire hydroquinone addition procedure.
Three partial grids were completed during the ship loading (Table II). The vent recovery unit was hot operated during the ship loading as the ship's refrigeration and vent system was used. Century readings were generally below 40 ppm. Occasionally the readings would reach 70 ppm; once reaching 1,700 ppm. Most of these higher readings were near the base of the dock and hydro quinone station. Roadway samples from both the Century and glass bomb samples showed VCM at grid points 36 through 44.
Charcoal dosimeter results for the dockman near the dock shack were 6.4, 3.3, and 1.8 ppm VCM.
Century readings ranged between 30 and 700 ppm mainly due to leaking valves. A new type of bomb valve has been ordered for replacement. The vent vacuum hose connection to the sampling system leaded several times during the sampling operation
000082187 CCR
Page 2
Loading and Vent Line Flange Insertion:
Century readings showed most readings below 40 ppm. Column made operation showed
immediately after hose disconnect showed an estimated 52 ppm VCM.
CCR 000082188
TABLE I PERSONNEL EXPOSURE IRENE LOADING - JUNE 21, 22, AND 23, 1974
Job
Unblinding Hose Flanges VCM Heel Samples
Hydroquinone Addition
Ship Loading
Finish Cargo Sampling
Hose Flange Blinding
Position
Dockman
Shift Foreman
Dockman
Dockman (b) Dockman (b) Dockman (b) Manufacturing Chemist Dockman Dockman
Time Interval Hr. 0.20
2.75 1.50
5.33 3.83 5.68 2.55
0.267 0.267
TWA - ppm VCM ^ From Dosimeters
3.03
69.11 10.71
6.43 3.30 1;80 5.55fc>
5.73 7.45
(a) All employees protected with fresh air equipment. (b) Dock Area
(c) Not protected with fresh air mask.
CCR 000082V'
TABLE III GLASS BOMB SAMPLES FOR PARTICULAR JOBS
Job Sample of vent line going to our vent stack 20* North of guard shack at gate Finish samples #2 Starboard
ppm VCM 96,806 1.8 8.9
CCR 000082190
Grid Point
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 -32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
J
TABLE II GRID RESULTS SEE ATTACHED PLOT FOR GRID POINT LOCATIONS
Set I
thc
Bomb
1700 1043
10 9 9
Set II Thc Bomb
15 15 20-33
13-30 25
30-70
15 15-20
14 12
278
4
9 2.2
14 15 12 11 11 20-70 13-17 10
9 10
9
35.1 39.9
5.4
10 6.1
11 11
18-30
19.6 16.2
Set III THC Bom5
13 30-40
30 30 30 28 18 15 18
*
12.3
15 15 10
27 13
27.7
4
9 15-22 12-20 10-22
4.2 7.5 3.7
8.5
14 3.5
CCR 000082X91 18 5.8