C' apter 6: Analysis of Bulk Samples
'*'**' ................................... .. ............ ..
.......................... ' .l .. *l,...
It is important that analyses of bulk samples are performed by the recommended technique. In choosing a laboratory, assistance from the State Asbestos Program contact or the EPA Regional Asbestos Coordinators is recommended.
What kind of analysts should be requested? Analysis of friable material bulk samples by the following techniques Should be requested:
1) Polarized Light Microscopy (PLM) 2) X-Ray Diffraction (XRD) as necessary to supplement the PLM method.
Why are PLM and XRD recommended for bulk sample analysis?
Polarized Light Microscopy (PLM) is a technique used to identify asbestos fibers by their shape and unique optical properties. It is a relatively inexpensive and quick method for identifying asbestos in bulk samples. PLM is particularly suitable for examination of the complex mixes of friable construction materials.
X-Ray Diffraction (XRD) is recommended where a second, independent analytical technique is necessary to confirm an analysis by PLM. It is a more expensive analytical method than PLM.
For more information on these analytical techniques, see pages 1-4-2 to 1-4-3 of Part 2.
K..- ' d ''-.A-
Is Electron Microscopy recommended for bulk sample analysis?
ElwtfoqJ^^pyimiV^
~
analytical technique for bulk sample asbestos analysis.
EM is costly, time-consuming, and limited in
availability.
For more information on Electron Microscopy, see
pages 1-4-3 of Part 2.
Is Phase Contrast Microscopy recommended?
Phase Contrast Microscopy is a technique used to count
ifibers present in air samples. It is unacceptable for
itification of asbestos in bulk samples. Do not-
roscopy.v vi"
v..!- * ..
for more information on Phase Contrast Microscopy,
see pages 1-4-5 to 1-4-6 of Part 2.
P !zed Light Microscope
Is there a standard analytical protocol for bulk sample asbestos analysis?
A standard protocol for bulk sample analysis is not currently available. However, guidelines have been prepared for bulk sample asbestos analysis using PLM and XRD. These guidelines are included as Appendix H to this manual and should be made available to the laboratories which perform the analyses of bulk samples.
8006 0326