Document QgEpzQaqw8zd4OjZEY1VB0V6L

r -p t trade price book for AMERICAN-STANDARD Hydronic Heating Equipment* Hydronics ... the science of heating and cooling with water. PRODUCTS Boilers -- Cast iron Electric Packaged Boilers Gas: Packaged Units Boilers Electronic Control Systems Oil: Packaged Units Boiler-Burner Units Flame Retention Boiler- Burner Units Boilers Oil Pressure Fired Gas Boiler-Burner Units Gee-Oil Coal: Stoker Fired Hand Fired Oil Burners and Controls Comfort Computer -- Zone Valve Peckegea Hydronic Assembling Tools Radiation: Scsc'Ooard Panels. Heatnm ' '-'ic'itt: r-aneis: Radiantrim . Arco, Sunrad ( << >ev - - Multifin Arco Cabinet Extras PAGE 39-40 2-6,9 7,8,10-16 17 18-19 20, 22-30, 33 29,30 21,22,28,31-33 23-28 36 37 33,35 34 38 41-44 45 45 46-48 49 50 rr - / - ; J .7 i tr rsj. - t, ` -Kia*" . : } - PACKAGED BOILERS GAS fired WATER fSIAMERICAN Si STANDARD HYORONIC HEATING GPMX PACKAGED GAS BOILERS Complt^tiyfactcry assembled and pre-wired. Two-toned brown and beige jacket encloses all controls. Regularly supplied for 115 volt 60 cycle power supply with 24 volt system or self ener gizing controls at no extra charge. (Specify controls desired) Built-in purge valve--Patent applied for. Built-in air separator, in left-hand end section. Intermittent circulator operation. Design certified by A. G. A. for combustible floor and closet installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for propane gas -- optional for natural gas at 10% reduc tion of rating as indicated by model number sufiix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2,000 feet. WATER -- for natural gas -- 100% shut-off pebtefcttoegrtd number GPMX-3 GPMX-4 GPMX-5 GPMX-6 GPMX-7 GPMX-8 A G A. input Mb* 66 99 132 165 198 231 Aew.Ctp.wAf. Ml* 52.8 79.2 105 6 132.0 158.4 184.8 net Jraartitnxgel Mb* 46,1 68.7 92.2 114.8 137.4 160.9 net rating wibotf*t* 307 458 615 765 916 1073 Trade Price ttawndithard gvEptnant $329.00 359.00 410.00 469.00 526.00 583.00 *Mpaa**n*gweight 197 240 264 335 381 428 chimney lii* inarde diem. in. height feet 4 10 5 10 5 10 6 10 7 10 7 10 WATER -- for propane gas -- 100% shut-off GPMX-3R 60 48 41.7 278 $329.00 197 4 10 GPMX-4B 90 72 62.6 417 359.00 240 5 10 GPMX-5R 120 96 83.5 557 410.00 284 5 10 GPMX-6R 150 120 104.3 695 459.00 335 6 10 GPMX-7R 180 144 125.2 835 520.00 381 7 10 GPMX-8R 210 168 146.1 974 583.00 428 7 10 Ordering Example*: Packaged bailer with standard equipment: 1 OPMX-d boiler with 24 vo<t control* Nat got. 7000 6tu, .6 tg 2 Pockoged boiler with optional equipment; I GPMX-7R boiler with 24 volt control* for conitant circulator operation, rum not, 1000 Bfu, .6 *g. kit from natural to propane Standard Equipment V800 series manifold gas valve includes main operator, manual shut-off, pilot filter, pressure regulator (except for propane gas) and Pilotstat. 1 %" Circulator with Piping Draft Hood Drain valve Wiring Harness ASME relief valve, 30 lb. Purge Valve Expansion Tank Auto Air Vent Automatic Fill Valve Specify 34 Volt . . . or . - . Specify Self Energising T822D thermostat L4080D limit control T822D thermostat L8148G limit and circulator relay (40VA) R8226B transformer (40VA) and circulator relay Note: Boiler is shiDped with jacket, all controls, circulator, main burners and manifold controls and piping factory installed and wired. Purge valve, air vent and expansion tank installed. Relief valve and thermostat fastened inside boiler crate. Draft hood shipped separately. Optional Equipment Optional constant circulation (24 V) L4081B limit and reverse acting circulator controls with AT20D transformer instead of 1,4080 and R8226B. Furnished at no additional charge. Optional constant circulation (S.E.) L40S1B limit and reverse acting circulator control and TS822A thermostat instead of L8I48G and T822D thermostat. Furnished at no additional charge. Conversion Kits: Boilers must be specified with suffix letter R. Reduced propane ratings apply. Natural to Propane gas Pronane to Natural gas W Trade Price 16.89 W Trade Price 16.89 Zone valve packages are available for water boilers. For details and prices, see page 34. -'2 '.ee ;aoe 52 Page 2 f 01519 .AMERICAN SiSTANDARD HYDRONIC HEATING PACKAGED BOILERS GAS FIRED WATER [| GP.V. PACKAGED GAS BOILERS Completely factory assembled and pre-wired. Two-toned brown and beige jacket encloses all controls. Regularly supplied for 115 volt 60 cycle power supply with 24 volt system or self ener gizing controls at no extra charge. (Specify controls desired) Built-in purge valve--Patent applied for. Built-in air separator, in left-hand end section. Intermittent circulator operation. Design certified by A. G. A. for combustible floor and closet installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for Propane gas -- optional for natural gas at 10'. reduction of rating as indicated by model number suffix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2,000 feet. WATER--for natural gas--100% shut-off pochagrt bail*' mwwAi GPM-3 GPM-4 GPM-5 GPM-6 GPM-7 GPM-8 A.G.A. input MAh 66 99 132 165 198 231 A.G.A. VtRttl MAh 52.8 79.2 105.6 132.0 158.4 184 8 fttf lalal rating MAh 46.1 68.7 92.2 114.6 137.4 160.9 oat rating t< water 307 458 615 765 916 1073 'qri.M* frit* with ttanOarp OWIpHMnt $304.00 330.00 388.00 446.00 504.00 561.00 apprax. tapping weight 200 240 285 335 385 430 ihitmoy mo imi4e Aiam. in. Height feer 4 10 5 10 5 10 6 10 7 10 7 10 WATER--for propane gas--100% shut-off GPM-3R GPM-4R GPM-5R GPM-6R GPM-7R GPM-8R 60 90 120 150 180 210 48 41.7 278 72 62.6 1 417 96 83.5 | 557 120 104.3 I 695 144 125.2 835 166 146.1 I 974 $304.00 336.00 388.00 446.00 504.00 561.00 200 240 285 335 385 430 4 5 5 6 7 7 10 10 10 10 to 10 Ordering Example*: 1 Packaged boiler with itandord equipment: ) GPM-5 boiler with 24 volt control* Nat got. 1000 Btu, 6 tg. 2 Pockoged boiler with optional equipment: 1 GPM-3R boiler with $lf-n<rrgttmg con trol* lor eonitont circulator operation. Propone go*. W See cape Standard Equipment V800 series manifold gas valve includes main operator, manual shut-off, pilot filter, pressure regulator (except for Propane gas) and Pilotstat. 1'4 " Circulator with Piping Draft Hood Drain valve Wiring Harness ASME relief valve, 30 lb. Purge Valve Specify 24 Veit . . . er , . . Specify Self Energising T822D thermostat L4080D limit control T822D thermostat L8148G limit and circulator relay (40VA) R8226B transformer (40VA) and circulator relay Note: Boiler is shipped with jacket, all controls, circulator, main burners and manifold controls and piping factory installed and wired. Relief valve and Thermostat fastened inside boiler crate. Draft :iood shipped separately. Optional Equipment Optional constant circulation (24 V) L4081B limit and reverse acting circulator controls with AT20D transformer instead of L4080 and R8226B. Furnished at no additional charge. Optional constant circulation (S.E.) L4081B limit and reverse acting circulator control and TS822A thermostat instead of L8148G and T822D thermostat. Furnished at no additional charge. Conversion Kits: Boilers must be specified with suffix letter R. Reduced Propane ratings apply. Natural to Propane gas Propane to Natural gas $6.89 $6.89 Zone valve packages are available for water boilers. For details and prices, see page 34. p age 3 01520 PACKAGED BOILERS GAS FIRED WATER I AMERICAN L5i STANDARD HYDRONIC HEATING G-2 PACKAGED GAS BOILERS Fully nnrlfoH pre-wired, and equipped with controls for forced circulation, the G-2 is a _ --quality, time-proven cast iron gas fired boiler available with and without tankless heater for domestic water requirements. This modern deluxe jacketed boiler features the patented "Eliminaire" (cast-in air sep arator in the left end section) and the distinctive American-Standard brown and beige jacket color combination to dress up any basement or utility room. The boiler is tested and equipped for 30 lbs. water working pressure and is regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system. Self-ener gizing controls are avalable without extra cost. Ratings shown are for installation at sea level and up to 2,000 feet. WATER--for naturol ond propone gases--100% shut-off paekagad boilar number A.QJL input Mbh A.QJL output Mbit tanklass haatar numbar A IsWsH rating net l=B=R rating Mbh nat rating a* ft watar 'VTrada Prlca with standard aquipmant appraa. hipping waight chimnay aita inside haight diam. in. faat Packaged boilers with factory installed tankless heater G-24-OPT G-25-DPT 90 120 72 218 2Vz 96 222 3 62.6 33.5 417 556 G-26-DPT 150 120 222 3>/ 104.3 695 G-27-DPT 180 144 222 3 Vi 125.2 834 *494.00 552.00 607.00 657.00 Packaged boilers less heater G-23-DP G-24-DP G-25-DP G-26-DP G-27-DP 60 48 90 72 120 96 150 120 180 144 41.7 62.6 83.5 104.3 125.2 278 417 556 695 834 *389.00 457.00 511.00 576.00 616.00 ^Gallons ol water per minute heated from 40F to 140F with 200F boiler water temperature. 416 481 551 620 333 403 472 542 603 5 10 5 10 6 10 6 10 4 10 5 10 5 10 6 10 6 10 Standard equipment V800 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat. l'A" Circulator with piping AS ME relief valve Draft hood (for G-23 only, shipped in separate carton) Pressure and temperature gauge Wirine harness AT20D transformer (24V. less heater boilers only) Additional standard equipment for boilers with heater Tankless heater as listed above T822D (24V.) thermostat L8124E (24V.) or L8124B (S.E.) triple Aquastat relay Ottering Examples: 1. Packaged boiler less heater with standard equipment. 1 G-24-0P boiler Nat. gas. 1000 Btu. .6 sg. 2. Packaged boiler with factory installed heater with optional equipment: ] G-26-DPT boiler with ribbon burners and Nat to Propane conversion kit. Nat gas. 1000 Btu. .6 sg. Additional standard equipment for boilers less heater T822D (24V.) or TS822A (S.E.) thermostat L4081B (24V. and S.E.) combination hie' limit and circulator control Nat*: Left hand end section less tankles: 'cater opening Na; Shipped with jacket, all controls (except thermostat), circulator and piping, main burners and manifold controls and piping factory installed and wired. Thermostat, manual main gas and pilot gas shut-off valves and relief valve shipped in accessory box fastened inside boiler crate. Optional equipment Self-energizing controls (consist of VS820 Series gas valve, thermostat. Q313 Thermopile Generator and limit or combination control as noted above), available when specified on order................................... no charge L8148E (24V.) or L8148G (S.E.) combination limit/relay in lieu of L4081B furnished on G-2 DP boilers no charge Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit": <>*'................................................ G-23 thru G-27 -w-Trade Price 66.00 Floor shield for combustible flooring. Add suffix letter "C" to boiler number add *3.50 Nata: In areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above. Zone valve packages are available for water boilers. For details and prices, see page 34. Page 4 01521 f51 AMERICAN IS STANDARD HYDRONIC HEATING PACKAGED BOILERS GAS FIRED STEAM G-2- PACKAGED GAS BOILERS For steam installation on new work or modernization, the G-2 Pack aged Steam boiler is available with either Flush or Deluxe jacket in the smart and attractive brown and beige combination that labels it an American-Standard top performing cast iron boiler. This model is factory assembled and pre-wired tor 115 volt, 60 cycle power supply with 24 volt control system. Where required, self-energizing controls are furnished without extra charge. Ratings shown are for installations at sea level and up to 2,000 feet. STEAM--for natural and propane gases--100% shut-off pachagad botlar number A.GJl. input Mbh A.G.A. output Mbh nat IsBsft rating Mbh sq ft Trada Met with standard aquipmant fldth Jacfcat daiwa Jaefcat approx. shipping waigM chtmnay six* inslda diam. in. haigbt faat G-23-SP* 60 48 36 150 8326.00 5343.00 310 G-24-SP* 90 72 54 225 395.00 412.00 376 G-25-SP* 120 96 72 300 454.00 471.00 443 G-26-SP* 150 120 90 375 510.00 527.00 518 G-27-SP* 180 144 108 450 559.00 576.00 581 4 10 5 10 5 10 6 10 6 10 * Add suffix letter "f" tor flush or "D" for deluxe ic*et Ortering Eiimpln.1. Packages boiler with standard eouioment 1 G-26-5P0 Boiler Nat. gas. 1000 Btu. .6 sg. 2. Packaged boiler with optional eouipment: 1 C-24-SPD boiler with self-energiting con trols Nat gas, 1000 Btu, S sg. ^ See cage 52 Standard equipment V80U Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat. No. 67-GAR (24V. and S.E.) low PA404A (24V. and S.E.) pressure water cut-off limit control Gauge glass with trimmings AT20D transformer (except S.E.) Draft hood (for G-23-D and G-23-F thru G-27-F, shipped in separate carton) T822D (24V.) or TS822A (S.E.) ASME safety valve Steam gauge Floor pan and radiation shield thermostat Now: Shipped with jacket, all controls (except those noted beiow), main burners and manifold controls factory installed and wired. Thermostat, low water cut-off, manual main and pilot gas shut-off valves (when required), safety valve and steam limit control shipped in accessory box fastened inside boiler crate. Optional equipment Self-energizing controls (consist of VS820 Series gas valve; Q313 Ther mopile Generator; and limit control as noted above) available when specified on order ........................................................................... no charge No. 101-24V. electric water feeder is available for addition to the No. 67-GAR to provide a low water cut-off and feeder combination control add*59.00 Natural to Propane gas conversion kits. Order boiler "with ribbon burners'' and "Natural to Propane conversion kit": G-23 thru G-27 Trade Price 56.00 No1*: in areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above. For Additional Optional Equipment, See page 15. For substitution of No. 47-2 low water cut-off and feeder combina tion (shipped separate! in place of No. 67GAR specify on order and ...................................................................... ......................... $44.00 Page 5 01522 HW. . PACKAGED BOILERS GAS FIRED WATER IAMERICAN SiSTANDARD HYDRONIC HEATING Q 2 PACKAGED ALL-PURPOSE GAS BOILERS Versatile and packed with pluses. Can be used for forced circulation or gravity installations. Completely factory assembled, pre-wired and crated with Deluxe brown and beige style leading jacket. Patented "Eliminaire" ends air problems. Tested and equipped for 30 lbs. water working pressure and regularly fur nished for 115 volt, 60 cycle power supply with 24 volt control system. Selfenergizing controls available at no added charge. Ratings shown are for installation at sea level and up to 2,000 feet. WATER--for natural and propane gases--100% shut-off pecfcafed boiler number A.OJt. input Mbh A.OA. output Mbh not ratine Mbh net ratine ft water ^ Trade Price with standard equipment leas thermostat approk. shipping weight chimney size Inside diem. in. heifht feet G-23-DPG 60 48 41.7 278 $285.00 G-24-DPG 90 72 62.6 417 355.00 G-25-DPG 120 96 83.5 556 417.00 G-26-DPG 150 120 104.3 695 474.00 G27-OPG 180 144 125.2 834 524.00 307 4 10 373 5 10 438 5 10 511 6 10 574 6 10 ) Orderinf Eumpiei: 1. Pictdged ill-purpose boiler with stindird equip ment. 1 G-25-DPG boiler Nit. {is, 1000 Btu, .6 S{. 2. Pickiged ill-purpose boiler with optional equip ment: 1 G 26 DPC boiler with self-energizing controls Nit {is. 1040 Btu, .65 s{. HH-l 2 Standard equipment V800 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat. L4080B (24V. and S.E.) immersion limit control ASME relief valve Pressure and temperature gauge AT20D transformer (except S.E.) Draft hood (for G-23-DPG only shipped in separate carton) Non: Shipped with all controls, main burners and manifold controls factory installed and wired. Manual main gas and pilot gas shut-ofT valves (when required) and relief valve shipped in accessory box fastened inside boiler crate. Optional equipment Self-energizing controls (consist of VS820 Series gas valve; Q313 Theimopile Generator; thermostat and limit control as noted above) avail able when specified on order ........................................................ no charge Natural to Propane gas conversion kits. Order boiler with "ribbon burners" and "Natural to Propane conversion kit": Trade Price 86.00 No,*: In areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above. Thermostats for 24V. and S.E. control systems are available. For prices see page 35. Zone valve packages are available for water boilers. For details and prices, see page 34. 01523 Page 6 AMERICAN kSi STANDARD HYDRONIC HEATING BOILERS--GAS FIRED WATER AND STEAM G-2 NON-PACKAGED ALL-PURPOSE GAS BOILERS As a water boiler, this model is available with or without tankless -oi! for don-.caiic water needs With steam trim it is a tup noicn modernization item. Two jacket styles-- Fiusn or Deluxe-this line is available in nine (9) sizes with factory assembled sections. Featuring the patented "Eliminaire" cast-in air separator in left end section, the boiler is tested and equipped for 30 lbs. water working pressure, 15 lbs. steam and is regularly furnished for 115 volt, 60 cycle power supply with 24 volt control sys tem. Self-energizing controls are available without extra charge. Ratings shown are for installation at sea level and up to 2,000 feet. WATER--Natural and Propane Gases--(Available with factory Installed Tankless heater, see options, pages IS A 16) --100% shut-off. toller number A.QJL. input Mbh A.6JL output Mbh net ratine Mbh net rating tp ft water Trade Pile# with standard equipment lea thermostat flush Jacket deluta Jacket approx. weight' chimney size Inside diam. in. height feet G-23-*W G-24-*W(T) G-25-*W(T) G-26-*W(T) G-27-W(T) G-28-*W(T) G-29-*W(D G-210-*W(T) G-211-*W(T) 60 90 120 150 180 210 240 270 300 48 41.7 278 $257.00 72 62.6 417 325.00 96 83.5 556 388.00 120 104.3 695 445.00 144 125.2 834 494.00 168 146.1 974 551.00 192 167.0 1113 216 187.8 1252 240 208.7 1391 807.00 657.00 713.00 $273.00 342.00 405.00 482.00 511.00 588.00 824.00 874.00 730.00 295 353 426 500 566 630 699 790 863 4 5 5 6 6 7 7 7 7 10 10 10 10 10 10 10 10 10 Substitute letter "f'` for flush or **0M for delude jacket. Suffix `T" denotes forced circulation Dollar equipped with factory installed tankless heater (see page 16 for addad charge). STEAM--Natural and Propane Gases--100% shut-off. boiler number A.G.A. input Mbh A.Q.A. output Mbh net l=8sft rating Mbh soft Trade Price with standard equipment less thsrmestat flush Jacket deluxe Jacket 1st chimney slat Inside diam. in. height feet G-23-*S G-24'S 60 48 36 90 72 54 G-25*S 120 96 72 G-26-*S G-27-*S G-28-*S 150 120 90 180 144 108 210 168 126 G-29-S 240 192 144 G-210-*S 270 216 162 G-211-*S 300 240 180 'Substitute letter "F" for flush or "O for deluxe jecket. 150 225 300 375 450 525 600 675 750 $303.00 371.00 434.00 491.00 540.00 597.00 853.00 703.00 759.00 $319.00 388.00 451.00 508.00 557.00 614.00 670.00 720.00 776.00 310 368 442 517 583 648 718 809 883 Standard Equipment 4 5 5 6 6 7 7 7 7 10 10 10 10 10 10 10 10 10 V800 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat. Ordering Cumpltt: 1. Non-oackiged kit-durooM water boiler with standard equipment and flush jacket: 1 G-27-FW boiler Nal gas, 1000 Bin. 6 sg. 2. Non-cackiged all-purpose water boiler with optional equipment and deluie jacket: 1 G-210-DWT boiler with (1) No. 232 tankless heater installed Nat gas. 1000 Btu. .6 sg For Other Optional Equipment. See page 15. AT20D Transformer (except S.E.) Drain valve Draft hood (for G-23-D and all flush jack eted boilers shipped in separate carton) Additional standard equipment Water boilers ASME relief valve Pressure and temperature gauge L4080 (24V. and S.E.) Aquastat limit control Net.: Zone valve packages are available for water boilers. For details and prices, see page 34. Steam boilers ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure limit control No:67-GAR (24V. and S.E.) low water cut-off Gauge glass with trimmings Floor pan and radiation shield Optional Equipment Electronic Control Panel Systems--see page 17 for prices, Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit": G-23 thru G-27 G-28 thru G-211 Trade PriceS&.OO Trade Price$8.10 See page 52 Page 7 HH-1? 01524 BOILERS--GAS FIRED WATER AND STEAM rz\ AMERICAN SJ STANDARD HTDRONIC HEATING G-40 GAS BOILERS This fine boiler is ideal for installation in larger residences, small apartments, and commercial buildings. Has deluxe jacket with built-in draft hood. Note that tankless heaters :c liable Xui both steam and water. Features ''Lumi naire" cSSt ITI the left end section. Regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system. Self-energizing controls optional. Tested and equipped for 50 lbs. water working pressure with 80 lbs. water pressure optional at extra cost. Tested ratings shown are for installation at sea level and up to 2,000 ft. WATER -- For Natural and Propane Gases -- 100% Shut-Off. For Built-In Water Heaters, see page 16. nvmber G-40J-W G-406-W G-407-W G-4010*W G-4011-W G-4012-W G-401J-W G-4014.W A.G.A. int Mbit 150 225 300 375 450 525 600 675 750 825 900 975 A.O.A. vtpwf Mbh 120 180 240 300 360 420 480 540 800 660 720 780 fWt IwBml miny Mbh 104.3 156.5 208.7 260.9 313.0 365 8 417 4 469.6 521.6 574 0 626.2 676.4 net rating n ft. wnt*f 69$ 1043 1391 1739 2066 2434 2782 3130 3479 3827 4175 4523 Trade Prtra with sfnndnrd Imi HiirnMat < 428.00 44.00 000.00 781.00 903.00 998.00 1111.00 1227.00 1344.00 1403.00 1870.00 1004.00 M'** thippwtf weight 827 1182 1686 1656 2026 2195 2364 2533 2702 diimiwy >is inside disn. in. 8 6 6 hsifht (mi 15 STEAM - For Natural and Propane Gases - 100% Shut-Off. For Built-In Water Heaters, see page 16. bsilst number G-404-S G*40S*S G-406-S G-40I-S G*4011-S G-4012-S G *4013-6 G-4014-8 A G.A. innut Mbh 150 225 300 375 450 525 600 675 750 625 900 975 A.G.A. eutpwt Mbh 120 160 240 300 360 420 480 540 600 660 720 760 net IssBs R rating Mbh 90.0 135.0 180.0 225 1 270 1 315.1 360.1 405 1 450.0 495.2 $40.0 585 1 e ft. 375 563 750 936 1125 1313 1500 1688 1875 2063 2250 2438 Trade Pries with etnnderd ysipniM 1 474.00 560.00 706.00 27.00 940.00 1041.00 1160.00 1273.00 1300.00 1509.00 1835.00 1740.00 npgran. thinning weight 858 1027 1105 1370 1544 1713 1600 2050 2219 2360 2557 2726 Ainner tilt inside diem. in. 8 8 8 10 height feet 15 10 10 12 12 12 12 15 Ordering tramples: 1. Water boiler Kith standard equipment: 1 G-406-W boiler Nat. (as. 1000 Btu. .6 S|. 2. Steam boiler with optional equipment: 1 C-409-ST 1 No. 226 tankless heater with controls Nat. (as. 1000 Btu. .6 s(. Standard equipment V800A Combination Gas Valve; (i-403 and G-404 for Natural Gas VBOOB Combination Gas Valve; G-403 thru G-407 for Propane Gas G-50AAG Combination Gas Valve: G405 and G-406 for Natural Gas V-88A Diaphragm Gas Valve; G-407 thru G-4014 for Natural Gas G-408 thru G-4014 for Propane Gas Gas pressure regulator (except propane gas) Manual main gas shut-olf valve Manual pilot gas shut-off valve where diaphragm gas valve is standard. AT20D Transformer (except S.E.) L62GB (24V.) or CS591A (S.E.) combination pilot switch and valve with auxiliary pilot valves (100% shut-off) Drain valve Water heater opening cover plates Additional standard equipment Water ASME relief valve Pressure and temperature gauge L4006A (24V. and S.E.) immersion limit control Zone valve packages are available for water boilers. For details and prices, see page 34. Steam ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure him*, control Gauge glass with trimmings No. F7-GAR (24V. and S.E.) low water cut-off Optional equipment (See page*. 15, 16 and 17) HH-12 Page B 01525 JAMERICAN ISi STANDARD HYDRONIC HEATING PACKAGED BOILER GAS FIRED WATER GWP PACKAGED GAS BOILER (Single Boiler Installation) The GWP bciU; package offers a ready-to-install heating plant for large residences, small apartment and commercial buildings. Designed for forced circulation only, the GWP includes factory mounted and wired controls. Burners are installed and deluxe jacket is factory mounted. Relief valve, temperature-pressure gauge and draft hood are shipped separately. The patented "Eliminaire" is also included. Boiler is tested and equipped for 50 lbs. working pressure and regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system. Self-energizing controls are available at no additional cost. Ratings shown are for installations at sea level and up to 2000 ft. WATER--100% shut-off--Natural and Propane Gas iMotir* GWP-5 GWP-6 GWP-7 A.G.A. **vt Mte+i 264 330 396 A.G.A. MMi 211 2 264 0 316 8 ** l*ll Mfcfc 183.5 229.6 275.7 thlwwwy tin Imid* 4i. m. twffM 7 15 8 IS 8 15 ***W wlfM 613 716 823 Trwte Mn vitft WipIWRl lii ihinMitO $456.00 551.00 657.00 Standard equipment Combination automatic gas valve Gas pressure regulator (except propane) Manual main gas shut-off valve Manual pilot gas shut-off valve AT-20D transformer (except S.E.) Pilot Valve & Switch Drain Valve ASME Relief Valve Pressure-Temperature Gauge Deluxe Jacket L4080D Immersion Limit Control Draft Hood Drilled Port Burners are standard for natural gas. Ribbon Burners are standard for propane gas and optional for nat ural gas. Optional equipment Self Energizing controls No Price Add Zone Valve Packages are available (for details and prices see page 34) * Add suffix "R" to model number if ribbon burners are desired. Example: GWP-5R Optional constant circulation (24 volt) L4081B limit and reverse actinp circulator controls instead of L4080 limit control. Added Trade Price g 10.90 Electronic Control Panel Systems, see page 17 for prices. For applica tion and details, contact American Standard. P'' See page 52 Page 9 HH-12 01526 MOOULAR GAS FIRED WATER BOILER f51 AMERICAN LSSTANDARD HYDRONIC HEATING GWM GAS MODULAR BOILER HOOK-UP (Modular. Boiler Installations) The GWM Modular Boiler Hook-up is a combination or multiple of five, six or seven section GWM boiler modules. Each module has factory assembled sections with burners, gas manifold, and automatic gas valve mounted. Deluxe jacket, controls and draft hood are shipped separately. The patented "Eliminaire" is a standard feature. Factory fabricated water manifolds are available as listed under optional equipment. GWM Modular Boilers are furnished for 1X5 volt, 60 cycle power supply with 24 volt control system. (Self-energizing controls are not available). Boilers are tested and equipped for 50 PSIG working pressure. Indicated ratings are for installation at sea level and up to 2000 ft. elevation. GWM BOILER MODULES - Natural and Propane Gas: 100% Shut-Off. m*4vl nwmbffe* GWM-5 AG.A. input 264 A.G.A. uMtpMwt 211.2 n#t Islsl raMtMinf 183.5 GWM-6 330 264.0 229.6 GWM-7 396 316.8 275.7 fcippiftf Wifhn lb. 629 735 846 Tro4with tlawdard qVlpfMflt !$ rhnnitar $443.00 538.00 644.00 Standard equipment Combination automatic Gas Valve Gas pressure regulator (except propane) Manual Main Gas shut-off valve Manual pilot gas shut-off valve Transformer Relay R8227B Pilot valve and switch Drain Valve ASME Relief Valve(s) as required Pressure-Temperature Gauge as required Deluxe Jacket L4080D Immersion Limit Control Draft Hood Drilled Port Burners are standard for natural gas. Ribbon burners are standard for propane gas and optional for nat ural gas. Optional equipment 1. Factory fabricated Water Manifold for Primary/Secondary circulation. Includes interconnecting supply piping (Boiler to manifold). Inter connecting return piping and circulator not included. .......................................................... Trade Price add per module 143.00 2. Factory fabricated Water Manifold for Parallel Boiler Hook-up. In cludes interconnecting supply and return piping (boiler to manifold). ......................................................... Trade Price add per module $87.00 3. Electronic Control Panel Systems, see page 17. For application and details, contact American Standard. Add suffix "R" to module boiler number if ribbon burners are desired. Example -- GWM-6R HH-12 See race i Page 10 01527 AMERICAN L5J STANDARD HYDRONIC HEATING MODULAR GAS FIRED WATER BOILER GWM GAS MODULAR BOILER HOOK-UP (Modular Boiler Installations) The following boiler units in 66,000 BTU input increments are achieved with module boiler combinations: MODULAR BOILER HOOK-UPS -- Natural and Propane Gas - 100% Shut-Off. volt nvmbtf GWM-528 GWM-594 GWM-660 GWM-726 GWM-792 GWM-858 GWM-924 GWM-990 GWM-10S6 GWM-1122 GWM-1188 GWM-12S4 GWM-1320 GWM-1386 GWM-1452 GWM-1518 GWM-1S84 GWM-1650 GWM-1716 GWM-1782 GWM-1848 GWM-1914 GWM-1980 GWM-2046 GWM-2112 GWM-2178 GWM-2244 GWM-2310 GWM-2376 GWM-2442 GWM-2508 GWM-2574 GWM-2640 GWM-2706 GWM-2772 GWM-2838 GWM-2904 GWM-2970 GWM-303E GWM-3102 GWM-3168 and upward modular competition S ItTt. 2 1 - _ -- 2 -- __ -- 1 __ -- _ -- - _ _ _ _ - _ _ __ _ -- __ - _ 4 lOct. _ 1 2 1 -- 1 2 3 2 1 _ 3 4 3 2 1 _ 5 4 3 2 1 _ 5 4 3 2 1 S 4 3 2 1 _ 5 4 3 2 1 7 MCI. -- - 2 - _ -- 1 2 3 - _ 1 2 3 4 - 1 2 3 4 5 1 2 3 4 5 6 2 3 4 s 6 7 3 4 s 6 7 8 gratt input Mbh S28 594 660 726 792 856 924 990 1056 1122 1188 1254 1320 1386 1452 1518 1584 1650 1716 1782 1848 1914 1980 2046 2112 2178 2244 2310 2376 2442 2508 2574 2640 2706 2772 2838 2904 2970 3036 3102 3168 groti output Mbh 422.4 475.2 528.0 580.8 633.6 686.4 739.2 792.0 844.8 897.6 950.4 1003.2 1056.0 1108.8 1161.6 1214.4 1267.2 1320.0 1372.8 1425.6 1478.4 1531.2 1584.0 1636.0 1689.6 1742.4 1795.2 1848.0 1900.8 1953.6 2006.4 2059.2 2112.0 2164.8 2217.6 2270.4 2323.2 2376.0 242B.B 2481.6 2534.4 not output Mbh 367.0 413.9 459.1 504.3 551.3 596.5 643.5 688.7 733.9 780.9 826.1 873.0 918.3 963.5 1010.4 1055.7 1102.6 1147.8 1193.0 1240.0 1285.2 1332.2 1376.4 1422.6 1467,6 1516.5 1561.7 1607.0 1652.2 1697.4 1746.1 1791.3 1836.5 1881.7 1927.0 1975.7 2020.9 2066.1 2111.3 2156.5 2205.2 approx. thippiny weight 1258 1364 1470 1581 1692 1993 2099 2205 2316 2427 2538 2834 2940 3051 3162 3273 3384 3675 3786 3897 4008 4119 4230 4521 4632 4743 4654 4965 5076 5367 5478 5589 5700 5811 5922 6213 6324 6435 6546 6657 6768 Modular Operating Control Package Options 1. Four stage ir.-.mersiofi tyjje operating control, (one required for up to 4 modules i J1?............... Trade price add per control $74.00 2. Immersion tyn^'iperating controls with individual outdoor resets. ................... Trade price add per module 150.00 3. Eight stage boiler sequencing control panel system with outdoor reset, (one required for up to 8 modules! Trade price add per control$286.00 Trod* Price with Bfondard opuipmont loit rhomtotiat $ 870.00 965.00 1060.00 1166.00 1272.00 1392.00 1487.00 1582.00 1688.00 1794.00 1900.00 2009.00 2104.00 2210.00 2316.00 2422.00 2528.00 2642.00 2748.00 2854.00 2960.00 3066.00 3172.00 3270.00 3376.00 3482.00 3588.00 3694.00 3800.00 3898.00 4004.00 4110.00 4216.00 4322.00 4428.00 4526.00 4632.00 4738.00 4844.00 4950.00 5056.00 01528 ^ See cace 52 Page 11 HH-12 non-packaged gas fired WATER P51AMERICAN ksaSTANDARD HTDRONIC HEATING GW NON-PACKAGED GAS WATER (Single or Modular Boiler Installation*) The GW Boiler is a non-packaged boiler available in three sizes designed for forced circulatton-only. Factory assembled sections are standard with jackets, burners and manifolds shipped separately. Included for field installation are a relief valve, tempera ture-pressure gauge, and draft hood. The patented "Eliminaire" is also included. Installed individually or in modular groups, the GW boiler is ideal for renovation work as well as new construction. Each boiler is tested and equipped for 50 PSIG working pressure and regularly fur nished for 115 volt, 60 cycle power supply with 24 volt controls. Self-energizing controls are available at no additional cost. Ratings shown are for installations at sea level and up to 2000 ft. elevation. INDIVIDUAL BOILERS - WATER - 100% shut-off - Natural and Propane Gas wuwBit* Gw-a GW-9 GW-10 AG-A ingui Mbit 462 528 594 A.C.A. wtpvt MM 369.4 422.4 475.2 IWf l*UI MM 321.7 367.0 413.9 chinmor fiu lm*M dia. in. 9 10 to fati 15 15 15 wvifM 938 1052 1177 Trod* with 1*91 ihftiMtwl (710.00 769.00 S27.00 MODULAR BOILERS - WATER - 100% shut-off - Natural and Propane Gas vn>t ftvmWr m*dwlor <*n**(*t* < Mil. f !<(- io Ir. yroit tnnvl MM r' MM n*f 9tpy MM GW-924 GW-990 GW-10S6 GW-1122 GW-1188 GW-1386 GW-1452 GW-1518 GW-1584 GW-1650 GW-1716 GW-1782 GW-1B48 GW-1914 GW-1980 GW-2046 200 924 1 10 990 0 2 0 1056 739 792 845 0 1 1 1122 879 0 0 2 1188 950 3 0 0 1386 1108 2 1 0 1452 1162 1 20 1518 1214 0 3 0 1584 1267 02 1 1650 1320 0 1 2 1716 1373 00 3 1782 1426 4 0 0 1848 1478 3 1 0 1914 1531 2 2 0 1980 1584 1 3 0 2046 1637 644 689 734 781 826 964 1010 1056 1103 1148 1193 1240 1285 1332 1376 1423 OBfffOI. Jiippiftf rvtyhN 1876 1990 2104 2229 2354 2814 2928 3042 3156 3281 3406 3531 3752 3866 3980 4094 Trod* Rrtc* wjNi standard qui^manf ln rh--maofot (1420.00 1479.00 1538.00 1596.00 1654.00 2130.00 2189.00 2248.00 2307.00 2365.00 2423.00 2481.00 2840.00 2899.00 2950.00 3017.00 Standard equipment Combination automatic gas valve Gas Dressure regulator (except propane) Manual gas shut-off valve Manual pilot gas shut-off valve AT-20D Transformer (except SE) Pilot Valve and Switch Drain Valve ASME Relief Valve Pressure-Temperature Gauge L-4080D Immersion Limit Control Deluxe Jacket Draft Hood Drilled Port Burners are standard for natural gas. Ribbon Burners are standard for propane gas and optional at no price add for natural gas. Optional equipment Self-energizing controls ........................................................... no price add Electronic Control Panel System, see page 17. For application and de tails. contact American Standard. Modular Operating Control Package Options 1. Four stage immersion type operating control (one required for up to 4 modules) .......................................Trade Price add per control 174.00 2. Immersion type operating controls with individual outdoor resets (one required for each module)............ Trade Price add per module$50.003 3. Eight stec; boiler sequencing control package with outdoor reset (one required for up to 8 modules) ...... Trade Price add per control (286.00 Add suffix "R" to model number if ribbon burners are desired. -IH-12 ^ See cage 52 Page 12 01529 I AMERICAN kSi STANDARD HYORONIC HEATING BOILERS-GAS FIRED WATER G-10 GAS BOILERS A compact, high capacity boiler for commercial and industrial application. Features single com bustion chamber to simplify wiring and controls. Built-in heaters available for storage tank or tankless application. Tested and equipped for SO lbs. water working pressure with 80 lbs. water working pressure optional at extra cost. Integral draft hood lm-s.ted st rear of boiler with optional top outlet (except G-1010) available at no extra cnarge. " WATER -- Noturol Gas -- 100% Shut-Off. For Built-In Water Heaters, see page 16. bolfar numbtr A.OJL Input Mbh A.QA. output Mbh A ot IkIbR piping and rating Mbh Pick-up factor a *"Trada Priea nat rating ag. ft watar with standard aguipmant tharmaatat appr>shipping walght cfclmnay sisa insMa dtam. In. hta Q-10S-W G-106-W G-107-W G-108-W G-109-W G-1010-W G-1011-W G-1012-W G-1013-W 6-1014-W 6-1015-W G-101S-W G-1017-W G-10H-W G-1019-W G-1020-W G-1021-W G-1022-W G-1023-W G-1024-W G-102S-W G-102S-W G-1027-W G-102S-W G-102B-W G-1030-W G-1031-W G-1032-W G-1033-W 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 640 800 960 1120 1280 1440 1600 1760 1920 2080 2240 2400 2560 2720 2880 3040 3200 3360 3520 3680 3840 4000 4160 4320 4480 4640 4800 4960 5120 556.5 695.7 834.8 973.9 1113.0 1252.2 1391.3 1530.4 1669.6 1808.7 1947.8 2087.0 2226.1 2365.2 2504.3 2643.5 2782.6 2921.7 3060.9 3200.0 3339.1 3478.3 3617.4 3756.5 3895.7 4034.8 4173.9 4313.0 4452.2 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 3710 4638 5565 6493 7420 8348 9275 10203 11131 12058 12985 13913 14841 15768 16695 17623 18551 19478 20406 21333 22261 23189 24116 25043 25971 26899 27826 28753 29080 91338.00 1627.00 1915.00 2223.00 2484.00 2748.00 3027.00 3379.00 3796.00 4102.00 4359.00 4628.00 4909.00 5204.00 5510.00 5767.00 6073A0 6342.00 6648.00 6929.00 7187.00 7493.00 7787.00 7996.00 8203.00 8521.00 8779.00 9035.00 9305.00 2706 3153 3827 4107 4584 5077 5568 8148 6659 7179 7752 8248 8744 9253 9765 10301 10778 11341 11851 12360 12891 13384 13876 14374 14878 15368 15891 16406 16936 14 14 14 16 16 18 18 20 20 22 22 22 22 24 24 24 26 26 26 26 28 28 28 28 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Tht r\*t isBsR ratings shown art batad on tha factors shown in tha piping and pickup column. Amoncan Standard should ba consuttad bafora salacting a botiar for installations having unusual piping and pickup raquirsmants. Standard equipment V88A or B50D gas valve(s) Drain valve Gas pressure regulator (except Draft hood Propane gas) L62GB combination pilotstat and Manual main gas shut-off valve H17BA1 pilot valves Manual pilot gas shut-off valve Pressure and temperature gauge AT20D Transformer L4006A immersion limit control Ribbon type main burners Optional equipment: See pages IS. 16 and 17. ASME relief valve Onltfing Examples: ]. Watar toilir. 1 C-J013-W boilsr Hit. (a*. 1000 Btu, 6 if. page 52 G-10 GAS BOILERS -- WATER for Propane Gas Propane Gas Ratings are determined by reducing the Natural ratings above by 10%. Example: G-105-W A.G.A. input 800 less 10%=720 Mbh Input for Propane Gas Detailed Propane Gas ratings are shown in current Technical Literature. Trade Prices, Chimney Sizes and shipping weights remain the same as shown above. Page 13 HH-12 01530 BOILERS-GAS FIRED STEAM (AMERICAN L5iSTANDARD HYDRONIC HEATING G-10 GAS BOILERS -- This steam boiler is ideal for new work or modernisation. Features a deluxe jacket which may be assembled to the boiler after piping has been installed. Integral draft hood locat ed at rear of boiler with optional top outlet (except G1010) available at no extra charge. Tins boiler is regularly furnished for 115 volt, 60 cycle power supply with 24 volt con trol system. Ratings shown are lor installation at sea level and uo to 2.1)00 ft. STEAM - For NatorafGas - 100% Shut-Off. For Built-In Water Heoters (G-1055 thru G-1014S only) See pogo 16. beilir numbtr A.GJL Input Mbh A.GJL output Mbh a nt 1 w B = ft rating Mbh aq. ft. lwB~* piping and pick-up factor A Trade Price with standard equipment IMS tharmoatat approx. ahipping weight chimn ay else inaida diam. in. hL ft G-10S-S G-106-S G-107-S 800 1000 1200 640 480.1 2000 1.333 $1382.00 2706 14 20 800 600.1 2501 1.333 1673.00 3153 14 20 960 720.2 3001 1.333 1961.00 3627 14 20 G-108-S 1400 1120 840.2 3501 1.333 2269.00 4107 16 20 G-109-S 1600 1280 962.4 4010 1.330 2530.00 4584 16 20 G-1010-S 1800 1440 1095.1 4563 1.315 2795.00 5077 18 20 G-1011-S 2000 1600 1227.9 5116 1.303 3074.00 5568 18 20 G-1012-S 2200 1760 1361.2 5672 1.293 3426.00 6146 20 20 G-1013-S 2400 1920 1489.5 6206 1.289 3843.00 6659 20 20 G-1014-S G-1015-S G-1016-S 2600 2800 3000 2080 2240 2400 1614.9 1739.1 1863.4 6729 7246 7764 1.288 1.288 1.288 4149.00 4406.00 4675.00 7179 7752 8246 22 22 22 20 20 30 G-1017-S G-1018-S G-1019-S 3200 3400 3600 2560 2720 2880 1987.6 2111.8 2236.0 8282 8799 9317 1.288 1.288 1.288 4957.00 5250.00 5557.00 8744 9253 9765 22 24 24 30 30 30 G-1020-S G-1021-S G-1022-S 3800 4000 4200 3040 3200 3360 2360.2 2484.5 2608.7 9834 10352 10870 1.288 1.288 1.288 5814.00 6119.00 6389.00 10301 10778 11341 24 26 26 30 30 30 G-1023-S 4400 3520 2732.9 11387 1.288 6695.00 11851 26 30 G-1024-S 4600 3680 2857.1 11905 1.288 6976.00 12360 26 30 G-1025-S 4800 3840 2981.4 12422 1.288 7233.00 12891 28 30 G-1026-S 5000 4000 3105.6 12940 1.288 7540.00 13384 28 30 G-1027-S 5200 4160 3229.8 13458 1.288 7633.00 13876 28 30 G-1028-S 5400 4320 3354.0 13975 1.288 6042.00 14374 28 30 G-1029-S 5600 4480 3478.3 14493 1.288 6250.00 14878 30 30 G-1030-S 5800 4640 3602.5 15010 1.288 8568.00 15368 30 30 G-1031-S 6000 4800 3726.7 15528 1.288 8826.00 15891 30 30 G-1032-S 6200 4960 3850.9 16046 1.288 9082.00 16406 30 30 G-1033-S 6400 5120 3975.2 16563 1.288 9351.00 16936 30 30 a The r>et l = B=R rating* shown are based on the factors shown m the piping and pickup column. American Standard should be consulted before selecting a boiler tor installations having unusual piping and pickup requirements. Standard equipment V88A or B50D gas valve(s) Gas pressure regulator (except propane gas) Manual main gas shut-off valve Manual pilot gas shut-off valve AT20D Transformer ASMfc safety valve Steam gauge Ribbon type mam burners Ordering Dimples: Slum froiitr with standard aquipmant I GI015-S boiler Nat |as. 1000 8tu. .65 if Drain valve Draft hood L62GB combination pilotstat and H17BA1 pilot valves PA404A pressure limit control Gauge glass with trimmings No. 67AR Low Water cut-off Optional equipment (See pages 15, 16 and 17) G-10 GAS BOILERS -- STEAM for Propane Gas Propane Gas Ratings are determined by reducing the Natural Gas ratings above by 10%. Example G-105-S A.G.A. Input 800 leas 10%=720 Mbh Input for Propane Gas Detailed Propane Gas ratings are shown in current G-10 Technical Literature. Trade Prices, Chimney Sizes and shipping weights remain the same as shown above. hH-12 See cage :' Page 14 01531 I AMERICAN k5i STANDARD HYDRONIC HEATING MISCELLANEOUS OPTIONS GAS BOILERS MISCELLANEOUS OPTIONS - NON-PACKAGED GAS BOILERS G-2, G-40 AND G-10 BOILERS: Thermostats are available at Trade Prices shown on page 35. Side Outlet ASME Steam Safety Valve may be substituted at no additional charge if specified on order to meet local code requirements. "IS" Equipment: boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. L4006A immer sion operating control for use m storage tank is required and will be furnished when specified on order at extra Trade Price as shown on page 35. This control operates gas valves on boiler electrically as required. Shipping weights of gas boilers for hot water supply are same as shown for regular gas boilers. No. 47-2 boiler water feeder and cut-off combination is available instead of the 67-AR regularly furnished with G-2, G-40 and G-105 thru G-108 steam boilers at additional Trade Price of ............................................................. $44.00 Low water cut-offs for water boilers: No. 63 cut-off for water working pressures of 50 lbs., or less, available when speci fied at additional Trade Price of $45.25 No. 150 cut-off for water working pressures in excess of 50 lbs. available when specified at additional Trade Price of ................................................................................................. $68.00 G-2 AND G-40 BOILERS: Self-energizing control: All size G-2 and G-40 for propane gas. All G-2 and G-40 thru G-4010 for natural gas. Equip ment includes: S.E. gas valve as required, Q313A Thermo pile Generator and a L4006 S.E. limit control (water boilers less heater) or an L8124B Triple Aquastat Relay (water boilers with heater) or a PA404A Pressuretroi (steam boilers less heater). For steam boilers with heater L4006A S.E. immersion operating control will be furnished in addi tion to the Pressuretroi. Furnished at no additional charge when specified on order. Special thermostat required, for Trade Price, see page 35. No. 101-24V electric water feeder can be added to the No. 67-GAR low water cut-off regularly furnished with steam boilers to provide low water cut-off and feeder combi nation at additional Trade Price of $59.00 Zone circulator control for water boiler with tankless heater and combination immersion control-relay: use one T822D thermostat and one R845A relay for second and/or third zone. For Trade Prices, see page 35. Water flow regulators sized for tankless heater involved will be furnished with heater when specified on order to meet local Utility requirement at Trade Pnce additional charge per heater of $3.50 G-40 AND G-10 BOILERS: No. 51-2 boiler water feeder and cut-off available instead of No. 67-AR regularly furnished with G-109 thru G-1033 steam boilers at additional Trade Price of .............. $67.00 Try-cocks and tappings: if desired for steam boiler to meet local code specify on order and add to Trade Price of steam boiler $4.50 Boilers tested for 80 lbs. water working pressure: available when specified i crder. Add per section to Trade Pnce of water boiler $8.50 per section G-2 BOILERS: "DW" (Direct Water) equipment: In addition to water boiler standard equipment, page 7, includes pressure gauge, 80 lb. ASME relief valve, L4006A Aquastat for storage tank, tank thermometer, name and rating plate for 80 lbs. water work ing pressure. Specify boiler with "DW" equipment and add $17.49 to Trade Price of All-Purpose Water Boiler, page 7. Floor shield for combustible flooring. Add suffix letter "C" to boiler number and add to Trade Price of boiler $3.50 G-40 BOILERS: Boilers with Tankless Heaters: water (for forced circulation) and steam boilers can be furnished with tankless heaters. Heaters are limited to boiler sizes as shown in ratings table on next page. Specify heater and add suffix "T" to boiler number. Factory assembled sections: G-403 through G-4014 can be shipped with sections factory assembled when specified on order. Add $11.66 per section to Trade Price of boiler. G-10 BOILERS: Pilot filters for G-10 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes. G-10 Steam Boiler external water heater tappings in cover plates: maximum size 154*. Specify number of cover plates with tapping. Added Trade Price per tapping $4.50 G-10 Right End Section Steam Trim Tappings for pressure gauge and water column fittings or for auxiliary controls furnished as standard equipment at no additional charge. Modulating gas valve: the G-10 boiler can be specified with the V4055A/5055B gas valve for Hi-Lo-off operation. This valve permits adjustment of the Lo-fire operation down to a minimum of 20% of the boiler input. Operation of the valve should be controlled by a SPST operating control. If desired, specify on order and add to the Trade Price of the boiler with regular equipment the following Trade Prices. G-105 thru 1018 ...................................................... $171.00 G-1019 thru 1033 $217.00 Top outlet draft hood (natural gas only); available (ex cept G1010) at no extra charge when specified on order. See current literature for chimney recommendations. Factory assembled sections: Available thru G-101J. Specify on order. Allow 3 week lead time. Added Trade Price per section $22.00 ' See cage 52 Page 15 01532 HH-T2 TANKLESS HEATERS-GAS FIRED WATER AND STEAM IAMERICAN ei STANDARD HYDRONIC HEATING G-2 TANKLESS HEATERS G-2 NON-PACKAGED ALL-PURPOSE BOILER: Factory installed tankless heaters: When hoilpr* Id thr-,1 11 section) are to be used -for-forced circulation. See table below for I=W=H ratings and applicable boiler size. Specify heater, add suffix "T" to boiler number and "factory installed." Add Trade Price shown. G-2 PACKAGED AND NON-PACKAGED ALL-PURPOSE BOILERS: Tankless heaters: When boilersj4 thru 11 section) are to be Uecvl fur forced circulation i=w'=ti tameless heaters can be installed in opening used for gravity tapping flange cover. See table for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below. Ratings ____________________________________________ Trade Prices bollor nurnbtr A.G.A. Input 0tu/hr. haatar 218 IsWkH Rating haatar 222 haatar 226 232 haatar 218 factory fnatallod $48.00 Old separata $25.00 G-24 90,000 2'/z G-25 120,000 3 G-26 150.000 3'/. _ 222 52.00 30.00 _ 226 <5.00 42.00 _ 232 73.00 51.00 G-27 G-28 G-29 180.000 210,000 240.000 3 Vi 4 3 Vi 4'/. _ `L8124E for 24 Volt or L8124B for SE, Triple Aquastat Relay furnished with 3 Vi 4 Vi 4Vi heater (packed in trim box). G-210 270.000 314 4 Vi 4% Water flow regulator. Specify on order. Added G-211 300.000 3 Vi 4 Vi 5 Trade Price............................................. $3.50 G-40 TANKLESS HEATERS -- STEAM OR FORCED WATER BOILERS Ratings (Gallons per minute*) Trade Prices iohar MUTER 211 HUTU 222 HUTU 228 HUTU 232 HUTU 445 HUTU 460 Staam Watar Stall* W|t*f Staam Watar Staam Watar Staam Watar Staam Watar 6-403 3 6-404 3 Vi 4 4 *'/t 6-405 3 Vi 6-406 3 Vi 4 4 *'/$ 5 Vi 6 4 5'/. 6 ---- ---- -- -- -- ---- -- 6-407 6-408 3Vi 4 3'A 4 <Vi 4 4 Vi fi 6'A 7'A -- -- 6 6`A 7 Vi 8 8 Vi 9 -- -- 6-409 6-4010 6-4011 6-4012 6-4013 6-4014 3 Vi 3 Vi 3'A 3 >4 3'A 3 Vi 4 4 4 4 4 4 6 6 Vi 7>4 8 8% 9 4 Vi 6 6 Vi 7`A 8 9 4 < Vi 6 SVz 7>A 8 'A 9 4 *Vi 6 6 Vi 7Vi 8 8 Vi 9 4 'A S 6`A 7'A a A 9 4 4 *<i 6 6 Vi 7Vi IVi 9 -- -- 11 12 13 13 'Gallons ot watar par mmuta aaa trom *Q*F ro 140*F with 200*F bonar watar tamparaiura. -- -- -- -- -- -- 12 13 1`A 15'A G-10 BOILERS --TANKLESS OR TANK TYPE HEATER No. 1023 heater is available in any quantity. Specify number required. Trade Price each $35.50 HUTU NO. HUTU WITH CONTROLS Watar Stumf) HUTU ONLY Watar ar Staam 218 $44.00 $40.00 S2S.00 222 48.00 49.00 30.00 226 01.00 97.00 42.00 232 70.00 64.00 91.00 445 4.00 90.00 99.00 460 00.00 09.00 71.00 Tankless heaters with controls for water boilers: L8124E combination immersion control-relay packed in trim box in place of standard limit control. Tankless heaters with controls for steam boilers: L4006A immersion operating control packed in trim box in addition to PA404A pressure limit control. Water flow regulator. Specify on order. Added Trade Price ..................................... $3.50 (') Additional L4006A operating control re quired for steam boiler-heater combina tions shown shaded. Add to above heater w/control Trade Price $15.00 The ratings table on this page shows the ratings attained if more than one heater is connected in parallel. Copper pipe manifolds, factory assembled for multiple heater parallel hookup, shipped in boxes of 2 manifold assemblies per box, when specified with heaters, are avail able at the following charges: Manifold Assembly Two Heater Three Heater Four Heater Tride Price $ 7.75 $11.75 $14.75 All G-10 water boilers and sizes G-105S thru G-1014S steam boilers can be provided with sections for insertion of heaters at no extra charge. When desired add suffix letter T to boiler number and specify the number of sections with heater openings. Cover plates to close unused water heater openings will be furnished only if specified on order at Trade Price each $4.75 When specified, the G-10 water boiler with heater can be provided with the combination L8124E in place of the L4006A limit control at the added Trade Price of $19.50 When No. 1023 heaters are used in steam boilers, the L4006A operating control will be required for installation in a heater tapping. See page 35 for Trade Price. When the No. 1023 heaters are used in a storage type domestic hot water system, the L4006A operating control will be required for insertion in a storage tank, see page 35 for the Trade Price. NO. 1023 HEATER RATINGS TANKLESS APPLICATION boifor numtar no. of tanklots haatora Intarmlttowt draw haatar rating gpm @ 100 rtaa praitur* drop (with manifold*) PSI <2-105 - G-1033 G-105 - G-1033 G-106 * G-1033 G-108 G-1033 1 2 3 4 4 V* 7/, 10 12*4 19 14 12 11 NOTE: Haatar* for Staam 8oilor avtifabla 5 thro 14 tactions anty STORAGE TANK APPLICATION haifor niimbtr mimbar af haatar* G-105 G-1033 G-105 G-1033 G-106 G-1033 G-108 G-1033 G-1011 G-1033 G-1013 G-1033 G-1014 - G-1033 G-1016 G-1033 <2*1018 G-1033 G-1020 0-1033 G-1022 G-1033 G-1024 . G-1033 1 2 3 4 5 6 7 8 9 10 11 12 continuum draw 190* hM ipm 4 7 10 13 16 19 22 25 28 31 34 37 apaStr 100* rim IP* 240 420 600 780 960 1.140 1.320 1.500 1.680 1.860 2.060 2.220 bailor output raaulrad mbh 200 350 500 650 800 950 1.100 1.250 1.400 1.550 1.700 1.850 NOTE. Haatar* tor Staam Boilar* availablt 5 thro 14 mctiant only. startga tank stia tali. 500 500 500 1.000 1.000 1.000 1.500 1.500 1.500 2.000 2.000 2.000 HH-12 See rage 52 Page 16 01533 L^SIANUARD HYDRONIC HEATING F.M./F.I.A. SPECIAL GAS CONTROLS ELECTRONIC CONTROLS NOTE: FIA always requires Gas Train (1) plus Electronic Control Panel System (2) FM requires Gas Train (1) and may require Electronic Control Panel System (2) (1) G-40 AND G-10 CONTROL OPTIONS G-40 AND G-10 BOILERS: F.M. or F.I.A. equipment F.I.A. require* special f* train PLUS F.I.A. electronic panel Special gas manifold control equipment that meets F.M. or F.I.A. minimum requirements are available at the Trade Price listed. For actual F.I.A. installations and before boiler installation, signed approval by F.I.A. inspector of both electronic controls and gas manifold control equipment being used should be obtained. Submittal data for F.M. or F.I.A. equipment is available from American-Standard. Electronic control systems are available as described and at the Trade Prices listed below. Note: A low water cut-olT for water boilers (50 lb. or 80 lb. water working pressure) will be furnished as required and charged for at the prices shown for No. 63 or No. 150 on page 15. F.M. A F.IA. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY) BOILER NUMBER ADD TO BOILER TRADE PRICE r.u.c) 7.I.A.O G-403 thru G-4014 G-10S thru G-108 G-107 G-108 thru G-1011 G-1012 thru G-1017 G-1018 G-1019 thru G-1030 G-1031 thru G-1033 $ 89.00 77.00 80.00 80.00 129.00 174.00 180.00 231.00 $493.00 465.00 501.00 506.00 690.00 753.00 602.00 932.00 F.M. gee control equipment includes two manual nui*oft valves, a test vont valve and one AH2/V710 Hydromotor Valve F.I.A. gas control equipment includes two manual ahut-otf valves. Hi and LO pressure switches, two AH2/V710 Hydromotor Valves and a vent valve. (2) GAS BOILER ELECTRONIC CONTROL PANEL SYSTEMS (FOR 115 VOIT, 40 CYCLE 1 PHASE POWER ONLY) Panel System EPG-M: Provides manual ignition, 100% safety shut-off with electronic supervision of pilots 1 to 3. Main burners and pilots are turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Baso valves and thermocouples and Q-179B electronic flame rod and pilot; RA890F protectorelay installed on panel; 3 ft. flame rod wire per pilot. Panel System EPG-ES: Provides electronic supervision of each pilot (1 to 3) and interrupted continuous burning pilot electronically turned off and electrically relighted on every cycle to achieve positive component check of relays and pilot system. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panels with 2-4 seconds response timing and alarm con tacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot. Panel System EPG-E: Provides electronic supervision of each pilot (1 to 3) and intermittent electric ignition of all pilots. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panel with 2-4 seconds response timing and alarm contacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot. Panel System EPG-M(FIA): Specifically designed to meet FIA requirements. Provides constant burning manually lighted electronically supervised pilots (1 to 3). 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; alarm bell, alarm silencing switch; purge timer, all factory assembled in master panel; RA 890F protectorelay installed in panel; Baso valves and thermocouples and Q-179B electronic flame rod pilot; 3 ft. flame rod wire per pilot. ADDITIONAL CHARGES-Z.Trade Price Specify on order type of system desired, as described above, and add charge for boiler size involved to Trade Price of boiler with regular equipment. PANEL SYSTEMS EPG-M Boiler no. system no. G-2, GW. G-40 EPG-M1 G-105 thru G-1012 EPG-M1 G-1013 thru G-1023 EPG-M2 G-1024 thru G-1033 EPG-M3 added charge <i) 5206.00 205.00 396.00 594.00 PANEL SYSTEMS EPG-E boiler no. system no. G-2, GW, G-40 EPG-E1 G-105 thru G-1012 EPG-E1 G-1013 thru G-1023 EPG-E2 G-1024 thru G-1033 EPG-E3 added charge (1) $225.00 228.00 420.00 530.00 PANEL SYSTEMS EPG-ES boiler no. system no. added charge (1) G-2. GW, G-40 EPG-ES1 $272.00 G-105 thru G-1012 EPG-ES1 272.00 G-1013 thru G-1023 EPG-ES2 464.00 G-1024 thru G-1033 EPG-ES3 675.00 PANEL SYSTEMS EPG-M(FIA) boiler no. system no. added ehargo G-2. GW, G-40 EPG-MI(FIA) $376.00 G-105 thru G-1012 EPG-MI(FIA) 376.00 G-1013 thru G-1023 EPG-M2(FIA) 575.00 G-1024 thru G-1033 EPG-M3(FIA) 782.00 Flame Rod Wire: Trade Price per foot Ignition Cable: Trade Price per foot $0.40 Q ec (') Note: If purge timer 11 desired. specify order and add $$2.00 Trade Price *Tr#d# pncn *00111 to eauioment whin thiQPOd with POiler. For field conversion*, pries on application W See page 52 Page 17 HH-12 01534 PACKAGED BOILER-BURNER UNITS WATM filAMERICAN kS STANDARD HYORONIC HEATING DP (Ti-as/105 PACKAGED BOILER-BURNER UNITS The ideal boiler-burner unit combining compact dry base design with the efficient DH-F flame retention burner. Dual bring rate allows for job flexibility. Two nozzles supplied with each boiler. Furnished with controls for forced circulation. The DP(T)-95/105 boiler is tested and equipped for 30 lbs. water working pressure. 115/GO/I electrical characteristics are standard. WATER piekigid umt number groee IseSsR output mbh isBsft bumor capacity gpe tonkloM heater number tankitae hoator capacity gpm ---------------- 1 not ISpBft rating mbit not rating ag- ft. water Trade Price WHfl tender* equipment approi. hipping weight chimney ate Packaged unita with factory installed tankless heater with R-8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control. DPT-95 95 .90 218 3 82.6 550 $540.00 496 8x8x15 .90-80'S DPT-105 105 1.00 218 3 91.3 606 540.00 496 8x8x15 1.00-80'S Packaged units less tankless heater with L40S0B Aquastat limit control, and separate R8184G light sensing primary control. DP-95 95 .90 -- DP-105 105 1.00 -- -- 82.6 550 $500.00 -- 91.3 608 SOO.OO Gallon* of water per minute from 40*? to 140*? with 200*? botier water temperature. NOTE Water volume 9-6 gallons. 481 481 8x8x15 8x6x15 .90-80'S 1.00-80'S Standard equipment: Model DH-F Arroflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat. Light weight insulating fire brick com bustion chamber. Nozzles--Two (high firing and low fir ing rate) each boiler. Draft regulator. ASME relief valve. Pressure and temperature gauge. 1VL" circulator and piping Wiring harness. Drain valve. Note: Units are shipped with flush jacket and with all electrical controls (except thermostat), circulator and piping, fac tory installed and wired. DH-r Arcoflame oil burner shipped separately. Draft reg ulator, relief valve and thermostat shipped inside boiler crate. Two-stage fuel unit is available for DH-F oil burner. Specify on order and add to Trade Price ......................................... $6.50 HH-12 See sage 52 Page IB 01535 d AMERICAN STANDARD HYDRONIC HEATING PACKAGED BOILER-BURNER UNITS WATER VP(T) PACKAGED BOILER-BURNER UNITS Hivh performance. compact.. wt base boiler matched with highly efficient flame re tention burner ideal -for renovation and replacement jobs as well as for quality new construction. DH-F burner, quiet 1725 RPM, flame retention type designed and proven for reliability and performance. Notales for two firing rates provided with each of three section arrangements (3, 4, 5). Dual firing rate allows for job flexibility and possible expansion while always maximising domestic hot water capacity. Furnished with controls for forced circulation. The VP(T) boiler is tested and equipped for 30 lbs. water working pressure. 115/60/1 electrical characteristics are standard. ATEB peckeged unit number gross IsBsB output men IsIsR burner capacity 0P* tankless heater number tankleaa heater capacity gpm net IsBsR rating mbh Ml rating q. ft water Trade Price with standard equipment ppm shipping weight chimney site water volume (!.) noala toes iekaged units with factory Installed tankleee heater With R8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control. VPT-115 VPT-130 115 130 1.05 130 3V4 100.0 667 5580.00 575 1.15 130 314 113.0 753 5(0.00 575 8x8x15 8x8x15 15.6 ' 15.6 1.00-60* semi solid and 1.10-60* semi solid VPT-170 VPT-190 VPT-230 VPT-250 170 190 230 250 1.50 131 4% 147.8 985 700.00 685 1.70 131 4% 165.2 1102 700.00 685 2.05 132 6 200.0 1333 790.00 795 2.25 132 6 217.4 1449 790.00 795 8x8x15 8x8x15 8x8x15 8x12x15 20.0 20.0 24.4 24.4 1.50-80* solid and 1.65-80* solid 2.00-60* semi solid and 2.25-60* semi solid ekaged units less tankless hestar VP-115 VP-130 VP-170 VP-190 VP-230 VP-250 115 1.05 -- 130 1.15 -- 170 1.50 -- 190 1.70 -- 230 2.05 -- 250 2.25 -- With R8182F Aquastat-relay combination, limit and circulator control, light sensing primary control, one heater opening cover plate. -- 100.0 667 5540.00 560 -- 113.0 753 540.00 560 -- 147.8 985 660.00 670 -- 165.2 1102 660.00 670 -- 200.0 1333 729.00 780 -- 217.4 1449 729.00 780 8x8x15 8x8x15 8x8x15 8x8x15 8x8x15 8x12x15 15.6 15.6 20.0 20.0 24.4 24.4 1.00-60* semi solid and 1.10-60* semi solid 1.50-80* solid 1.65-60* solid 2.00-60' semi solid 2.25-60* semi solid tiiona of water per mmute from 40aF to 1*Q*F with 2DQ*F boiler watte temperature. Sfe 5age 52 Standard equipment: Model DH-F Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat. Scientifically designed pre-cast refrac tory combustion target wall. Nozzles--Two (high firing rate-lo firing rate) each boiler. Draft regulator. ASME relief valve. Pressure and temperature gauge. 114" circulator with piping. Wiring harness. Drain valve. Not#: Units are shipped with flush jacket and with all electrical controls (except thermostat), circulator and piping, fac tory installed and wired. Arcoflame oil burner shipped separately. Draft regu lator, relief valve and thermostat shipped inside boiler crate. Zone valve packages are available for water boilers. For details ar.d prices, see page 34. Ordering Eiomple: 1. Pockoged unit with healer with equipment* l VFT-I15 boiler-burner unit 2. Packaged unit leu heoter with equipment: 1 VP-115 boiier*a.jfiief * (fondord standard Page 19 HH-12 01536 BOILER-BURNER UNITS WATU AND STUM LSII AMERICAN STANDARD HYDRONIC HEATING A-3 NON-PACKAGED ALL-PURPOSE BOILER-BURNER UNITS If you prefer your oil-fired boilers unpeckaged for convenience and flexibility, choose the A-3 Non-Paekaged Boiler-Burner unit in one of five sizes for water or steam, with or without tankless heater. This boiler offers you A-3 versatility. It can be used on 45^ forced circulation or gravity systems or steam. New improved ratines are achieved witn present DH-5 oil burner having 1,725 rpm motor. The flush jacket installs easily and provides free access to all controls and burner for quick adjustment and servicing. The factory assembled sections are tested and equipped for 30 lbs. water working pres sure. Motor and controls are regularly furnished for 115 volt, 60 cycle power supply. WATER befler* burner unit number ima Isftsft output Mbh Isftsft burner capacity ph Unfciecs heater number A IsWsH rating net Isftsft rating Mbh* net rating aft watar 'Trade Price with atandorri equipment jsssu weight chimney tee Forced circulation units with factory installed tankless heater With R8182D Aquastat-relay combination, high limit, low limit and circulator < A-33M-WBT 108 1.00 222 4 A-34M-WBT 148 1.35 230 4 A-35M-WBT 188 1.70 328 4>/e A-36M-WBT 228 2.20 335 5 Vi A-37M-WBT 268 2.50 335 5 VI 93.9 128.7 163.5 198.3 233.0 626 856 1090 1322 1553 $509.00 07.00 715.00 816.00 908.00 666 756 878 1016 1148 8x8x 15 8x8x15 8x8x 15 8x8x 15 8x 12 x 15 Forced circulation units less heater With R8182F Aquastat combination, limit and circulator control, light sensing primary control. A-33M-WB A-34M-WB A-35M-WB A-36M-WB A-37M-WB 108 148 188 228 268 1.00 1.35 1.70 2.20 2.50 93.9 128.7 163.5 198.3 233.0 626 858 1090 1322 1553 $474.00 571.00 886.00 763.00 859.00 658 740 875 1005 1138 8x8x 15 8x8x 15 8 x 8 x 15 8x8x 15 8x 12 x 15 Gravity units less heater: With L4O80A Aquastat limit control, and separate R8184G light sensing primary contra A-33M-WBG A-34M-WBG A-35M-WBG A-36M-WBG A-37M-WBG STEAM boiler* burner unit number 108 1.00 148 1.35 188 1.70 228 2.20 268 2.50 grots Isftsft output Mbh IsftsR burner capacity gph tankJeea heater number IsWsH rating 93.9 128.7 163.5 198.3 233.0 net Isftsft rating Mbh 626 858 1090 1322 1553 $469.00 566.00 661.00 758.00 854.00 nat Isftsft aft steam ^FTrade Price with etandard equipment 657 739 874 1004 1137 8x8x15 8x8x 15 8x8x15 8x8x 15 8x12x15 approx. hipping weight chimney ixe Steam units with factory installed tankless heater With PA404A Pressuretrol, L4006A Aquastat operating control, and separate R8184G light sensing primary control. A-33M-SBT 108 1.00 222 3 Vi 81.0 338 3509.00 A-34M-SBT 148 1.35 230 3 Vi 111.0 463 6073)0 A-3SM-SBT 188 1.70 328 4 VS 141.0 588 715.00 A-36M-SBT 228 2.20 335 4 Vs 171.0 713 816.00 A-37M-SBT 268 2.50 335 5 Vi 201.0 838 908.00 667 752 879 1017 1149 8x8 x 15 8x8x IS 8x8x 15 8x8x 15 8x 12 x 15 Steam units less heater With PA404A Pressuretrol, and separate R8184G light sensing primary control. A-33M-SB A-34M-SB A-35M-SB A-36M-SB A-37M-SB 108 148 188 228 268 1.00 1.35 1.70 2.20 2.50 81.0 338 $469.00 111.0 463 5663)0 141.0 686 661.00 171.0 713 758.00 201.0 838 854.00 658 740 875 1005 1138 8x8x 15 8x8x 15 8x8x 15 8x8x 15 8x 12 x 15 Nozzle sizes, gen, 70 soils, furnlsned witn tn sbove units: A-33, 1.00: A-34, 1.3S; A-35. 1.75: A.36. 2.25; A-37, 2.50. AGailons of watar par minute hasted from 40*F to 140*F with 200*F bo.Ur watar tamparatura. Standard equipment: Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat. Scientifically designed pre-cast refrac tory combustion chamber. Nozzle. Draft regulator. Drain valve. Units WITH water heater: 1 cover plate with Vs- control tapping. Units LESS heater: 2 cover plates for heat er openings. Zone valve packages are available for water boilers. For details and prices, see page 34. Ordering Examples: 1. All-Purpose boiler-burner unit wilh standard equipment: For forced circulation, wilh heater: 1 A-37M.WBT boiler-burner unit For groviry circulation: 1 A-33M.WBG boiler-burnar unit 2 AII-Fu.-pose boiler-burner unit with optional -uo- '7..'3n:: .''I, n rd circulation, loss hoalor: 1 >.-35M-WB boilor-burnor unit wilh twostage fuel unit. Water ASME relief valve. Pressure and temperature gauge. Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings. Optional equipment: See page 22. Page 20 01537 d AMERICAN STANDARD HYDRONIC HEATING OIL FIRED BOILERS WATEt AMD STEAM A-3 ALL-PURPOSE OIL FIRED BOILERS For the boiler that spells quality and dependability, look no further than the A-3 with factory-assembled cast iron sec tion assembly that is tested and equipped for 30 lbs. water working pr**urc. The flush jacket slips on easily. This _ boiler provides outstanding performance. See page 52 WATER pm IsBsIt output lAbh IsBsIt bumor capacity *ph tank!cos heatar numbor l=W=H rating not IsBsIt rating Mbh Boiler with factory installed tankless heater--forced circulation not rating Wfl wator 'Trodo Plica approx. SB1 A-33M-WT A-34M-WT A-35M-WT A-36M-WT A-37M-WT 108 148 188 228 268 1.00 222 4 1.35 230 4 1.70 328 4/ 2.20 335 5>/4 2.SO 335 S*A Boiler lesa heeter--gravity or forci>d circuittion 93.9 128.7 163.8 198.3 233.0 626 868 1090 1322 1553 $3344)0 432.00 840.00 841,00 737.00 613 698 825 962 1093 8x8x15 8x8x15 8x8x15 8x8x15 8x12x15 A-33M-W A-34M-W A-35M-W A-3SM-W A-37M-W 108 1.00 148 1.35 188 1.70 228 2.20 268 2.50 93.9 128.7 163.8 198.3 233.0 626 858 1090 1322 1S53 $307.00 4044)0 499.00 890.00 802.00 605 687 822 951 1083 8x8x15 8x8x15 8 x 8 x 15 8 x 8 x 15 8x 12 x 15 STEAM Dollar numbar pm IsBsIt output Ubh IsBsIt bumor capacity BPb tanklooa hootor numbor A JsWsH rating Boiler with factory instilled tankless heater A-33M-ST 108 1.00 222 3'/s A-34M-ST 148 1.35 230 3`/2 A-35M-3T 188 1.70 328 4/ A-36M-ST 228 2.20 335 4>/ A-37M-ST 268 2.50 335 5>/ Boiler lesa heater not IsBsft rating Mbh 81.0 111.0 141.0 171.0 201.0 not IsBsIt OB ft stoam ^Trada Price 338 $334.00 463 4324)0 588 540.00 713 641.00 838 737.00 approx. SUSP chimney slxo 614 699 826 963 1094 8x8x 15 8x8x 15 8x8x15 8 x 8 x 15 8x12x15 A-33M-S A-34M-S A-35M-S A-36M-S A-37M-S 108 1.00 148 1.35 188 1.70 228 2.20 268 2.50 81.0 338 $307.00 111.0 463 404.00 141.0 588 409.00 171.0 713 5964)0 201.0 838 6924W 606 688 823 952 1084 A Gallon* of water par mmuta haattd from 40*F to 140*F with 200*F bailor wator tamparatura. 8x8x15 8x8x15 8x8x15 8 x 8 x 15 8 x 12 x 15 Only i*B*R approved oil burnou, such as tha OH-5 burner, may ba usad with A3 oil flrad Dollars. Othar i*BR approvad burnars ara available, Consult your American Standard Olstrlct Office for details. Standord equipment: Scientifically designed pre-cast refrac tory combustion chamber. Drain valve. Water ASMS relief valve. Pressure and temperature gauge. Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings. Optional Equipment, See page 22. a-35 -- A-37 Sent Anemones available ;cs:c` trade price cnar9e of $17.00 Meta: Boilers with factory Installed tewiri-.. beater are ihipped with one water heater opening cover plate with y.' control tap ping. Boilers less factory installed heater are shipped with an additional water heater opening cover plate (blank). Zone valve packages are available for water boilers. For details and prices, see page 34. Ordering Exempt..: 1. Water boiler loti heater with tfandard equip. merth 1 A-34M.W boiler 2. Steam boiler with heoter with standard equip* merit! 1 A-36M-ST boiler 3. Water boiler with heater with optional equip* ment: I A-35M.WT boiler with jacket exten.ion Page 21 HH-12 BOILER-BURNER UNITS Oil FIRED BOILERS WATU AND STEAM d AMERICAN STANDARD HYDRONIC HEATING OPTIONAL EQUIPMENT VP(T) PACKAGED BOILER AND A-3 FOR A-3 BOILER-BURNER UNITS AND OIL FIRED BOILERS Jacket extension: Jacket extension provides 15H' enclosure in front for concealment of oil burner and controls. Approx imate shipping weight 35 lbs. Specify on order. Added Trade Price ........................................................................ $34.00 McDonnell & Miller No. 67AR low water fuel cut-off for quick hook up installation is available for A-3 steam boilers at added Trade Price of................................... $33.00 Controls and control sets are shown on page 35. The No. 5Z Control Set can be used for circulator zoning with A-3 boiler-burner units with tankless heater. 1 No. 5Z set is required for each zone in addition to the first zone which is controlled by the No. 5 Control Set or equivalent. Added Trade Price $27.75 Non-packaged A-35 thru A-37 split section assemblies are available. Added Trade Price ..................................... $17.00 FOR VP(T) PACKAGED BOILERS Two-stage fuel unit is available for DH-F oil burner at added Trade Price ...............................................................$630 Order R8182E Aquastat-ielay combination instead of R8182F (less tankless only) control to provide room thermostat control of circulator. Added Trade Price.. $5.75 FOR A-3 ALL-PURPOSE BOILER-BURNER UNITS Two-stage fuel unit is available for DH-5 oil burner at added Trade Price charge of.......................................................... $630 For substitution of No. 4 control set consisting of T822D thermostat, L4081B Aquastat limit and circulator control, plus R8184G light sensing primary control, instead of R8182F combination control, for non-packaged A-3 boilerburner units for forced circulation LESS heater. Added Trade Price .................................................................... $1335 For substitution of No. 5 control set consisting of T822D thermostat, L8124C Aquastat, limit, reverse and operating control, circulator relay, plus R8184E light sensing primary control, instead of R818ZD combination control, for nonpackaged A-3 boiler-burner units for forced circulation WITH tankless heater. Added Trade Price................ $535 Order R8182D Aquastat-relay combination instead of R8182F control to permit use of tankless heater with A-3 non-packaged boiler-burner units furnished less water heater. Added Trade Price ........................................... $1030 Order R8182E Aquastat-relay combination instead of R8182F control to provide room thermostat control of circulator. Added Trade Price .....................................$5.75 |=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR A-3 Heaters tested with boilers. Built-in tankless heaters can be ordered (or separate shipment with units or boilers specified less heater as follows: unit no. tsBsft bumar capacity a* haattr no. A IsWsH ratine watar otaam ^FTrada Net A-33 A-34 A-35 A-36 A-37 1.00 1.35 1.70 2.20 2.50 222 230328 335 335 4 4 4/ 5V4 5% 3>/2 $30.00 3>/j 31.00 4>/ 44.00 4/ 48.00 5>/4 46.00 A Gallons of watar por mmuta haatad from 40*F to 140*F with 200*F boilar wator tamparatura. HH-12 See sace 52 Page 22 01539 HYORONIC HEATING PRESSURE FIRE0 BOILER-BURNER UNITS WATM AND STEAM PFA-3 PRESSURE FIRED BOILER-BURNER UNITS The PFA-3 Pressure Fired Boiler is forced-draft with flame retention burner using No. 2 oil for over 80% efficiency. Attractive two-toned brown and beige jacket with optional matching acoustically treated jacket extension. Wet base construction eliminates need for separate base. Perfect seal between boiler sections is achieved with durable sealant. Factory assembled sections are tested and equipped fur SO lbs. water working pressure. Motors ur.d conti uis regularly furnished for 115 volt, 60 cycle power supply. WATER bailee home* e*ft Smet Imtmt eelpwt atM e l|at burner capacity Vb t tmWmti Hag net Ie8t reelwg Mbb net yr Me Price wf* standard "Sag veal slat dtam. la. Forced circulation unit* with fectory installed tankless neeter: No. 3 control tot -- T822D thermostat, U4124C Aouactat, reverse ano operating control, circulator retay RI184G light tensing primary control. PFA-34-WT PFA-35-WT PFA-36-WT PFA-37-WT 300 375 450 526 2.65 226 6.0 260.9 1739 S 961,00 3.30 232 7.5 326.1 2174 108SX0 3.95 445 9.0 391.3 2609 1219.00 4.60 445 9.0 457.4 3049 1338X0 905 1096 1287 1481 8 8 8 8 Forced circulation units less naater; No. a control sat -- TS220 tnarmostat, L40S1B Aquastat limit and circulator control RB184G 119m Mining primary control. PFA-34-W PFA-35-W PFA-3S-W PFA-37-W 300 2.65 375 3.30 450 3.95 526 4.60 260.9 326.1 391.3 4S7.4 1739 2174 2609 3049 f 911.00 1029.00 1147.00 126SX0 894 1085 1276 1470 8 8 8 8 STEAM Steam units with factory Installed tankless heater: No. 2 control set -- TJ22D thermostat, PA404A Pretsuretroi, L4006A Aouastat operating control. R8104G llgnt sensing primary control. PFA-34-ST 300 2.65 226 6.0 225.1 938 S 953.00 905 6 PFA-35-ST 375 3.30 232 7.5 281.3 1172 1080X0 1096 8 PFA-36-ST 450 3.95 445 9.0 337.6 1407 1211X0 1287 8 PFA-37-ST 526 4.60 445 9.0 394.6 1644 1330.00 1481 8 Steam units less neater: No. 2 control Mt-~T8220 thermostat, PA404A Pretsuretroi, R8284Q llgnt sensing primary control. PFA-34-S PFA-35-S PFA-36-S PFA-37-S 300 2.65 375 3.30 450 3.95 526 4.60 225.1 281.3 337.6 394.6 938 1172 1407 1644 S 899.00 1017.00 1135.00 1253.00 900 1091 1282 1476 8 8 8 6 'Nozzle sizes furnished with the above units: (S -- solid: H -- hollow) PFA-34. 2.50 fph 70* S; PFA-3S. 3-25 fph 45* 5; PFA-36, 4.00 fph 45* S. PFA-37. 4.50 fph 30* $. tGellen* of water per minute heated from 40*F to 140*F with 200*F boiler water temperature. Vent needs to extend only 3 feet above highest part of roof. Standard Equipment Water: ASME relief valve Pressure and temperature gauge Flange mounted oil burner with 2-atage fuel unit; factory installed light sensing cad cell with bracket and lesda: V4046B instantaneous oil valve; Syracuse elec tronic time delay; drain valve. buttur-buniur unit PFA-34 PFA-35 elf burner LC-334-A3 LC-334-A better-burner PFA-361 PFA-371 ett burner LC-534-A StMm: ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment Available in split assemblies. Specify on order. Added Trade Price ............ S17.00 For other optional equipment see page 24. Units WITH water heater; 1 cover plate with \ " control tapping. Units LESS water hester: 2 cover plates for heater openings. Ordering Example*: 1. Pressure fired boiler-burner unit with *?oniord equipment with heoter for water: 1 PPA-34-WT boiler-burner unit 2. Pressure fired boiler-burner unit with op tional equipment leu heoter for iteom: 1 PPA-37-5 boiler-burner unit with jockef extension je 52 Page 23 Zone valve packages are available for water boilers. For details and prices, see page 34. 01540 PRESSURE FIRED BOILER-BURNER UNITS Wm AND STEAM AMERICAN SiSTANDARD HYDRONIC HEATING PFA-3 OPTIONAL EQUIPMENT Acoustically treated brown and beige jacket extension: Jacket extension provides 1714' enclosure in front for con cealment of oil burner and controls. Approximate shipping weight 42 lbs. Specif? on order. Added Trade Price... >40.00 No. S-Z control set for circulator zoning with PFA-3 boilerburner units equipped for tankless heater. 1 No. 5-Z set is required for each zone in addition to the first zone which is controlled by the No. 6 control set or equivalent. Trade Price of ............................................................................. >27.75 McDonnell & Miller No. 67AR low water fuel cut-off for quick hook-up installation is available for PFA-3 steam units at added Trade Price of........................................ $33.00 McDonnell & Miller No. 63 low water cut-off is available for PFA-3 water units at added Trade Price of......... >45.25 Controls and control sets are shown on page 36. I=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR PFA-3 Heaters tested with boilers. Built-in tankless heaters can be ordered for separate shipment with units or boilers specified less heater as follows: Wfllt PFA-34 PFA-35 PFA-36 PFA-37 bwmpr (city A 2.65 3.30 3.95 4.60 a*. 226 232 445 445 laWaH rtb* MM, IlMR 6.0 6.0 7.5 7.5 9.0 9.0 9.0 9.0 CallR> of wt*r par wtrtvf* from 4C*P to 140*P wills ?00*F bailor wetor tompororwo. fhr* liiin nN flaw 23 pti 36 psi 37 pti 37 psi TfW* Prlcb >42.00 51.00 65.00 55.00 HH-1 2 3 6 r Page 24 01541 PFA-5 PRESSURE FIRED BOILER-BURNER UNITS PFA-5 Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 80% efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure is optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. 5 Vent neeua to eAltrnu uiuy 3 feei above highest part of roof. BOILER-BURNER UNITS STEAM ANO WATM Fmwn find b*iif hwmw unit iwmka it rtu wtpwt MM PFA-504-* 0(T) PFA-S05-* 0(T) PFA-506-* 0(T) PFA-507-* 0(T) PFA-508-* 0(T) PFA-509-* 0(T) 620 786 950 1116 1282 1446 PFA-S10-* 0{T) PFA-511-* OfT) PFA-512-* OfT) 1612 1776 1944 PFA-513-* 0(T) PFA-514-* OfT) PFA-515-* 0(T) PFA-516-* OCT) PFA-517-* 0(T) PFA-516-* 0(T) 2108 2272 2440 2604 2768 2936 PFA-51#-* 0(T) 3100 PFA-520-* 0(T) 3260 PFA-521-* OfT) 3430 bvmpr capacity 41 5.45 6.90 8.35 9.80 11.20 12.65 14.10 15.55 16.95 18.40 19.85 21.25 22.70 24.15 25.60 27.00 28.45 29.90 plolog o*4 pickup factor SIM wafer not 1 m | 1 rating Mbh tlcmw Bloofmt- 1.333 1.333 1.333 1.333 1.330 1.315 1.15 465.1 539.1 1.15 589.6 683.5 1.15 712.7 826.1 1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099.6 1257.4 1938 2467 2969 3488 4016 4582 1.302 1.292 1.288 1.15 7238.1 1401.7 1.15 1374.6 1544.3 1.15 1509.3 1690.4 5159 5728 6289 1.288 1.288 1.288 1.288 1.288 1.288 1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7 1.15 7021.7 2264.3 1.15 2149.1 2407.0 1.15 ^279.5 2553.0 6819 7350 7893 8424 8954 9498 1.288 1.288 1.288 1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6 10028 10546 11096 Mt rating aq. H. wafer 3594 4557 5507 6469 7432 8383 9345 10295 11269 12220 13171 14145 15096 16047 17020 17971 18899 19884 Trod* Pr'co with itmdord quipofeot oH not i dim*. la. $1490.00 10 1764.00 10 1964.00 10 2280.00 10 2529.00 10 2709.00 14 3173.00 14 3689.00 14 3962.00 14 4144.00 14 4358.00 14 4662.00 14 5013.00 18 5227.00 18 5509.00 18 5760.00 18 5980.00 18 6186.00 18 Oppt--* knot* ahtpplog -v`ht burner m*d*i iwpplid with tiondord *qwipm*at 1840 2210 2520 95A-1-6702-JBT 96A-M-6131-JC-T 96A-M-6131-JC-T 2880 3190 3550 96A-B-8316-JC-T 96A-B-6318-JC-T 96A-B-8318-JC-T 3935 4285 4845 96A-T-A-8419-JC-T 97A-T-A-6614-JC-T 97A-T-A-8614-JC-T 4955 5317 5875 5985 8345 5750 97A-T-A-8614-JC-T 97A-T-A-8615-JC-T 97A-T-2-7635-E-1 97A-HM.O-2-7685-E-1 97A-HM.O-2-7685-E-1 98A-HI-L0-2-7771 -E-1 7060 7420 7780 98A-Hi-L0-2-7771 -E-1 98A-H1-L0-2-7771 -E-1 98A-HI-L0-2-7771 -E-1 The n*' I --S_t rating! shown art band on piping and pick.up allowances listed abort. American.Standard should ba consulted boforo selecting a boiler for installations hoving unusual piping and pick-up requirements. -Subetitute loner "S" for steam: "W" for water. Stert Up end One Year's Service ... Price on Application Suffix (T) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heatan, sec page 28. W Nome sires, gph, furnttned witn the above oit burners are as toitows: mit m. gph. typ* wait a*. gph. typ* wait n*. gph. typ* Wflit IW. ppA- *yp waH m. gph* typ* wait M. gph. typ* PFA-504 2 2.75 90*H PFA-505 2 3.50 90* H PFA-506 2 4.00 80* H PFA-507 1 4.50 70*H 1 5.00 70*H PFA-508 2 5.50 80'H PFA-509 1 6.00 80 *H PFA-512 2 7.00 70*H PFA-514 1 3.50 60* H PFA-517 1 10.00 90* S PFA-620 1 6.00 80'S 1 6.50 80*H 1 2.50 70 *H PFA-515 2 8.00 70*H PFA-618 1 7.50 90 *S 1 8.50 80'S PFA-510 2 5.50 90*H PFA-513 2 7.00 70*H 1 5.00 70* H 1 8.00 90*S 1 12.00 80* S 1 2.75 90* H 1 4.00 70*H PFA-515 2 7.00 90*S 1 10.00 90*S PFA-621 2 8.00 80*S PFA-511 2 6.50 80* H 1 8.50 90*S PFA-519 2 7.50 80*S 1 14.00 80 *S 1 2.00 80* H PFA-514 2 8.00 60*H PFA-517 2 7.00 90*S 1 12.00 B0*S Standard Equipment--All Boilera Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Oil Fired Flange mounted oil burner--97A-T-A, 97A-T-2, 97A Hi-Lo and 98A Hi-Lo burners furnished with flange and pedestal; 2-stage fuel unit. On 95A-1, 96A-M, 96A-B, 96A-T-A and 97A-T-A burners, factory installed cad cell, bracket and leads, R8185E light sensing primary control; V4046B in stantaneous oil valve, ST70A1002 electronic time delay. On 97A-T-2, 97A Hi-Lo-2 and 98A Hi-Lo-2 burners, R4150A control--provides pre-purge and post-purge, Q520A base, factory installed C7013A photo cell; delayed and instantan eous oil vsive;, nozzles. Standard r.'oro- Voltages PFA-oOf thru PFA-510 PFA-611 ttm PFA-621 115/60/1 230/60/1 Ord*rinq Examples: PfA-S boiler-burntr unit for steam with standard oquipmont. -P*A-5W-SO boiler-burner unit *tA-5 ffO'ij'-burnor unit for water with opti.' f'1 equipment. I --Ff , i -WOrT) with laeket extension; 4 iWn. tankless htotwri; v/ith 16006A control. Optional Equipment--Oil Fired Oil Burners equipped to meet F.M. and Massachusetts Code requirements for PFA-504 through PFA-614 Units are available when specified on order. Added Trade Price...................................................... $169.00 Burners for PFA-515 through PFA-521 already equipped to meet F.M. requirements. Equipment includes: R41E0A pro vides pre- and post-purge, C7013A Photo Cell and Q520A Base. Oil Burners to meet F.I.A. requirements--Price on applica tion. Oil burners for PFA-515 thru PFA-521 to meet Massa chusetts Code requirements -- Price on application. Prewired Control Panels on burners - prices on application. Optional burners available forPFA-504 thru PFA-E10, see page 28. See page 52 Page 25 HH-12 01542 GAS boiler-burner units STEAM AND WATER PFA-5 PRESSURE FIRED BOILER-BURNER UNITS PFA-S Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 80% efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure is optional at caua cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. Vent needs to extend only 3 feet above highest part of roof. prauwra firW biif-burnt unir wumbar rwi 1 a wr ut*1vt Mhh Isl-t bwenar i input Mb* piping on4 pickup foe ton worn nvf Ib| c| rosing Mb* iion wator I*. He tlatfn Mf rating H H. woitar PFA-504-* G(T) PFA-505-* G(T) PFA-506-* G(T) PFA-507-* G(T) PFA-508-* G(T) PFA-509-* G{T) PFA-510-' G(T) PFA-511-* G(T) PFA-512-* G(T) PFA-S13-* G(T) PFA-514-* G(T) PFA-515-' G(T) PFA-516-* G(T) PFA-S17-* G(Tj PFA-518-* G(T) PFA-519-* G(T) PFA-520-* G(T) PFA-521-* G(T) 620 786 950 1116 1282 1446 1612 1776 1944 2108 2272 2440 2604 2768 2936 3100 3260 3430 763 966 1169 1372 1568 1771 1974 2177 2373 2576 2779 2975 3178 3381 3584 3780 3983 4186 1.333 1.333 1.333 1.333 1.330 1.315 1.302 1.292 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.15 465.1 539.1 1.15 589.6 683.5 1.15 712.7 826.1 1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099.6 1257.4 1.15 1238.1 1401.7 1.15 1374.6 1544 3 1.15 1509.3 1690.4 1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7 1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0 1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982 6 1938 2457 2969 3468 4016 4582 5159 5728 6289 6819 7350 7893 8424 8954 9498 10028 10546 11096 3594 4557 5507 6469 7432 8383 9345 10295 11269 12220 13171 14145 15095 16047 17020 17971 18899 19884 Trwda fries with Hipsdfd qwipmanf $2349.00 2881.00 2803.00 3133.00 3390.00 3579.00 4081.00 4814.00 4027.00 8126.00 5340.00 5544.00 5887.00 5101.00 5294.00 6691.00 6883.00 7108.00 Fftw* Imato is* hipping atom. weight in. bvntof modal wppliad with standard aquipmanf 10 1840 R6.2-G-03-R4795-B 12S 10 2210 R6.2-G-03-R4795-B. 12S 10 2520 R6.2-G-03- R4795-B. 12 10 2880 R8-G-05-R4795-B.12 10 3190 R8-G-05-R4795-B.15 14 3550 R8-G-05-R4795-B.15 14 3935 R8.1-G-05-R4795-B.20 14 4285 R8.2-G-05-4150A-H.20 14 4645 R8.3-G-10-4150A-H.20 14 4955 R10.9-G-10-4150A-H.20 14 5315 R10.9-G-10-4150A-H. 20 14 5675 R10.9-G-10-4150A-H.20 18 5985 R10-G-15-4150A-H.25S 18 6345 R10-G-15-4150A-H.25S 18 6750 R10.1-G-15-4150A-H.26S 18 7060 R10.1-G-20-4150A-H.25 18 7420 R10.1-G-20-4150A-H.26 18 7780 R10.1-G-2tM150A-H.26 Tha n*t | --6--R rotir>g shewn are bated an piping and pick>up allowance* listed above. American-Standard should be consulted before selecting a boiler far installations having unusual piping and pick-up requirements. * Substitute letter "S" for steam; "W" for woter. START-UP AND ONE YEAR'S SERVICE: INCLUDED IN TRADE PRICE OF GAS UNIT.(I) Suffix (T) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heaters, see page 28. Standard Equipment--All Boiler! Steam: PA404A Pressuretrol. ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat. ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Gat Fired Flange mounted gas burner. Standard burner controls meet latest UL requirements. Dual automatic gas valves for add ed reliability. Gas-electric ignition. Electronic program ming controls and components are factory wired in a con trol cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burners equipped to operate with 1,000 Btu, 0.6 specific gravity natural gas. Ordering Examples: PFA-S boiler-burner unit for steam with standard equipment. 1 --PFA-514-SO boilet-butner unit PFA-S baiier-burner un,t For water with optional equipment. 1--PFA-Sll.WGCT) with jacket extension; 4 No. 549 tankless heaters. Specify gas pressure available at gas train inlet. (1) Surcharge for Start-Up and Service west of Mississippi River. Contact American-Standard for details. The comple. n*;ure of th, Cm and Gej-Oil Burners make them imprac tical lo since at b. nd Plant Therefore please allow 3 10 4 weeks i*d time fc `iftipment of SLjnatrd Equipped Burners after receipt of order et Hyuromc Order Center. Optional Equipment Factory assembled sections available. Specify on order. Added Trade Price -- Per section $22.00 PFA-5 units are available with controls to meet Factory Mutual and Factory Insurance Association minimum requirements at the following added charges: got fired bailor lisa F.M. -------- F.i.A. PFA-504--510 $753.00 $928.00 PFA-511--515 PFA-516--521 573.00 596.00 826.00 854.00 For prices of gas burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office. High Risk F.M. or F.I.A. requirements...... Hi-Lo Fire Control ....................................... Modulating Fire Control --...................... Alarm System pre-wired and mounted on control cabinet............................................ Optional Combustion Controls ...................... ^ on ^ ,ea,l0n Controls to meet local requirements .......... For Additional Optional Equipment, See page 28. Standard Motor Voltages go* bvmvc* PFA-504-511 PF A-512--521 115-60-1 230-60-3 Other optional motor voltages--Price on Application. HH-12 ^ See race 52 Page 26 01543 PFA-5 PRESSURE FIRED BOILER-BURNER UNITS PFA-5 Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 80^ efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. Vent needs to extend only 3 feet above highest part of roof. GAS-LIGHT OIL BOILER-BURNER UNITS STEAM AND WATER pmivt* fired betler burner go*--light oil 1 Blast grot* Islet burner capacity output Mbh .get Mb* piping end atom* water net e | s | rating iteam water ad. ft. ateam net ''Trade Price with itowdord rent approx imate equipment NooWf 4lm. weight per--ell burner medei auppHed wttb atowdord equfpmern gat - oil PFA-504-* GOfT) PFA-505-* GOfT) PFA-506-* GO(T) 620 763 786 966 950 1169 PFA-507-* GOfT) 1116 1372 PFA-508-* GOfT) 1282 1566 PFA-509-* GOfT) 1446 1771 PFA-510-* GOfT) 1612 1974 PFA-51T-* GOfT) 1776 2177 PFA-512-* GOfT) 1944 2373 PFA-513-* GOfT) 2108 2576 PFA-514-* GOfT) 2272 2779 PFA-515-' GOfT) 2440 2975 PFA-516-* GOfT) 2604 3178 PFA-517-' GOfT) 2768 3381 PFA-518-* GOfT) 2936 3584 PFA-519-* GOfT) 3100 3780 PFA-520-* GOfT) 3260 3983 PFA-521-* GOfT) 3430 4186 1.333 1.333 1.333 1.333 1.330 1.315 1.302 1.292 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.15 465.1 539.1 1.15 589.6 683.5 1.15 712.7 826.1 1938 2457 2969 3594 $2762.00 4557 2993.00 5507 3292.00 1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099.6 1257.4 3488 4016 4582 6469 7432 8383 3564.00 3899.00 4080.00 1.15 1238.1 1401.7 1.15 1374 6 1544.3 1.15 1509.3 1690.4 5159 9345 5728 10295 6289 11269 4S92.00 4971.00 5352.00 1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7 6819 12220 7350 13171 7893 14145 5554.00 5759.00 5972.00 1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0 8424 15095 8954 16047 9498 17020 6312.00 6527.00 6802.00 1.15 2406.8 2695.7 10028 17971 1.15 2531.1 2834.8 10546 18899 1.15 2663.0 2982.6 11096 19884 7132.00 7415.00 7640.00 10 10 10 10 10 14 14 14 14 14 14 14 18 18 18 18 18 18 1840 R6.2-GO-03-R4795-B.12S-FIC 2210 R6.2-GO-03-R4795-8.12S-FIC 2520 R6.2-GO-03-R4795-8.12 FIC 2880 R8-GO-05-R4795-B. 12-F3 3190 R8-G0-05-R4795-B.15-F3 3550 R8-GO-05-R4795-B. 1S-F3 3935 R8.1-GO-05-R4795-8.20-F3 4285 R8.2-GO-07-4150A.H.20-F4H 4645 R8.3-G 0-10-4150A-H.20-F4H 4955 R10.9-GO-10-4150A-H. 20-F4H 5315 R10.9-GO-10-4150A-H.20-F4H 5675 R10.9-GO-10-4150A-H.20-F4H 5985 R10-GO-15-41S0A-H.25S-F4H 6345 R10-GO-15^150A-H.2SS-F4H 6750 R10. l-GO-20-4150A-H.25S-F4H 7060 fl 10.1-GO-20-4150A-H.25- F4 H 7420 R10.1-GO-30-4150A-H.25-F4H 7780 R10.1-G0-3O4150A-H. 25-F4H Tho not I u t r (i rafingi shown ora baled on pioing and pick-up allowances lilted above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements. Substitute letter "S" for steom, "W" for water. START-UP AND ONE YEAR'S SERVICE; INCLUDED IN TRADE PRICE OP GAS-OIL UNIT.(I) Suffix IT) denores boiler with openings in center section for tankless hooters when specified. For Built-in Water Heaters, see page 26. Standard Equipment--All Boilers Steam; PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat. ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Gas-light Oil Fired Flange mounted combination gas-oil burner. Standard burner controls meet latest UL requirements. Manually operated fuel switch for dual fuel change-over. Dual auto matic gas valves for added reliability. Gas-electric ignition. Electronic programming controls and components are fac tory wired in a control cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burner equipped to operate on No. 1 or No. 2 fuel oil and 1,000 Btu, 0.6 specific gravity natural gas. Standard Motor Voltages uni' ge*eil bdfMn PFA-504--510 115-60-1 PFA-511 PFA-512-521 230*60-1 230-60-3 Other optional motor voltages--Price on Application. ID Surcharge for Start-Up and Service weft of Mississippi River. Contact Amcricon-Stondord for details. Ordering Exempt**: PFA-5 boil*f-bv'nr unit for iteom with standard equipment. 1 -- PFa-5 14-SOO boiler-burner unit. PFA-5 bol-* * untt for weir with opfionol equipment. PFA il*. VGOlTj with jacket extension; A No. 548 lenkleis hoofu':. Spocrfy 901 p-eiivr* ovoilobl# at got from inlet. Nozzle sizes, gph, furnished with combination ges-fignt oil burners ere es follows: (nozzlecapacity is dependent on oh pressure.) vail ne. gph. type unit ne. gph. type unit ne. gph. type PFA-504 1 4.00 90H PFA-505 1 5.00 90H PFA-506 1 6.50 90H PFA-507 2 4.00 90S PFA-508 2 4.00 90S PFA-509 2 5.00 90S PFA-510 2 5.00 90S PFA-511 2 5.50 90S PFA-512 2 6.00 90S PFA-513 2 7.00 60S PFA-514 2 7.00 60S PFA-515 2 7.00 60S PFA-516 2 7.00 60S PFA-517 2 8.00 60S PFA-518 2 8.00 60S PFA-519 2 8.00 60S PFA-520 2 8.50 60S PF A-521 2 9.00 60S Optional Equipment PFA-5 units are available with controls to meet Factory Mutual and Factory Insurance Association minimum requirements at the following added charges: peewit fired belief site P.M. P.I.A. PFA-504--510 PFA-511-515 PFA-516-521 $938.00 753.00 775.00 $1079.00 994.00 984.00 Automatic Fuel Changeover Trade Priced........................................................$194.00 For prices of gas-oil burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office. High Risk F.M. or F.I.A. requirements....... Hi-Lo Fire Control......................................... Modulating Fire Control.................................... Price Alarm System pre-wired and mounted on control cabinet............................................. on Optional Combustion Controls....................... Application Controls to meet local requirements .......... Th complex nature of the Gee end Cee^Oi) Burner* make them imprac tical to aLock at Bond Plant. Therefore, pleeee allow 3 to 4 week* lead time for ahiDment of Standard Equipped Burner* after receipt of urder et Hydronic Order Service Center. r See oage 52 age 27 01544 BOILER-BURNER UNITS OIL FIRED BOILERS WATTS AND STEAM rSl AMERICAN LSi STANDARD HYDHONIC HEATING PFA-5 OPTIONAL EQUIPMENT Jacket extension: Jacket efleftsion provides 34 >4" enclosure in front for concealment of burner and controls. Approxi mate shipping weight 90 lbs. Specify on order. Added Trade Price ...................................................................... $67.00 PFA-5 boilers tested for 80 lbs. water working pressure: available when specified on order. Add to Trade Price of water boiler...................... ............................... $8.50 per section Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows: PFA-5 ................................ Trade Price each..................... $4.10 Optional oil burners to provide low fire start (with cad cell) for PFA504 thru PFA508; Hi-Lo operation provided (with cad cell) for PFA509 and PFA510. Please allow four weeks lead time after receipt of order at the hydronic order service center. wdi PFA 504 PFA 505 PFA 506 PFA 507 PFA 508 PFA 509 PFA 510 burner tnedeJ 96A-T-A-8406 JBT 96A-T-A-8408 JBT 96A-T-A-8408 JCT 96A-T-A-8409 JCT 96A-T-A-8410 JCT 96A-HI LO-A-8808 JCT 96A-HI LO-A-8808 JCT ^4 la Trade Price $134.00 126.00 126.00 60.00 60.00 271.00 210.00 Factory assembled sections available. Specify on order. Added Trade Price per section .................... $22.00 *) TANKLESS WATER HEATERS FOR A-5, FRA-5 ANO PFA-5 Tankless water heaters are available in any quantity at the following Trade Prices: Ketci wwwhgr uftod with prti. drop at ratod flow Trod* Price eecfc 530 A-5. FR-A-5 548 PFA-5 15 psi 16 psi $42JO 70J0 PFA-5 units with tankless water heaters require additional controls at current prices as follows: STEAM: L4006A Aquastat operating control. Trade Price . $14.90 WATER: L6006A Aquastat operating and circulator control. Trade Price ...... $15.80 Factory assembled copper pipe manifold for parallel hook up of multiple heaters are available as follows: emnrield Trade Price* fee A-S. rt-A-S 2 Hutir...............................................................$ 0.70 3 Huttr............................................................... 12.70 ........................................................................ 16JO When suffix "T" is added to boiler number on order for A-5, FR-A-5 or PFA-5 boilers or units, maximum number of center sections with water heater openings are furnished at no extra charge as follows: Except where noted by asterisk in which case max. number of openings minus one is furnished unless max. number is specified on order. A-S ed Fl-A-J feeder A-S or FR-A-504-T A-5 or FR-A-50S-T thru 507-T A-5 or F R-A-508-T*thru 509-T A-5 or FR-A-510-T*thru 511-T* me*. ne. et 2 3 4 5 PFA-3 belter PFA-504-T PFA-505-T thru 506-T PFA-507-T thru 508-T PFA-509-T thru 511-T mi. ne. el evening* 1 2 3 4 PFA-S belief PFA-512-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PFA-520-T thru 521-T met. ne. el evening* 5 6 7 8 The following table shows ratings attained if more than one heater ia connected in parallel: tenkleu Kenter ne. 1J0 tonMetc Keefer Ne. 541 beilw wmWr ne et Keeler* raftng gem. better number ne ef Keeieri A-5 or FR-A-5-T all sizes A-5 or FR-A-5-T all size* A-5 or FR-A-505-T thru 511-T A-5 or FR-A-508-T thru 511-T A-5 or FR-A-510-T thru 511-T 1 2 3 4 5 4 PFA-5-T all size* 7 PFA-505-T thru 506-T 10 PFA-507-T thru 508-T 13 PFA-509-T thru 511-T 16 PFA-512-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PFA-520-T thru 521-T 1 2 3 4 5 6 7 8 *Gollni of oi#' Mr mmol* ronotf from d0*F to ld0*F *ith 200*F feeder woier femeererwre. rating fpen. 8 16 24 32 40 48 56 64 HH-12 MeDONNELL & MILLER LOW WATER CUT-OFFS STEAM: No. 369 Low Water Cut-off for A-5, FR-A-5, PFA-6 ............................ No. 47-2 Feeder and Cut-off for A-6, FR-Ar5, PFA-604 thru PFA-609 No. 51-2 Feeder and Cut-off for PFA-510 thru PFA-521 ....................... WATER--50 PSI: No. 63 Low Water Cut-off for A-6. FR-A-6 and PFA-5........ WATER--0 PSI: No. 150 Low Water Cut-off for PFA-6 .................................. Page 28 Tro*. M" 8 27.00 77.00 100.00 45.25 88.00 01545 (^AMERICAN caSTANDARD HYDRONIC HEATING boiier-burner units WATK AND STiAM FR A-5 FUME RETENTION BOILER-BURNER UNITS The FR-A-5 is a perfect combination of boiler and burner teamed for top performance. Develops 12)4 COz. Tested and equipped for SO lbs. water working pressure. Motors and controls regularly furnished are for 115 volt, 60 cycle power supply. WATER boiler-burner unit number output Mbh bumor capacity IP* not rating Mb* not ratine 4. ft orator Trade Prico ortth standard equipment For Built-in Water Heaters, Steam and Water Boilers, see page 28. stripping weight chtiminnoy FR-A-504-WB(T) FR-A-505-WBfO FR-A-506-WB(T) FR-A-507-WBfn FR-A-508-WB(T) FR-A-509-WB(T) FR-A-510-WB(T) FR-A-511-WB(T) 384 472 560 648 736 824 912 1000 3.55 4.30 5.10 5.90 6.70 7.45 8.25 9.05 333.9 410.4 487.0 563.5 640.0 716.5 793.0 869.6 2226 2736 3246 3756 4266 4776 5286 5797 $1087.00 1204.00 1405.00 1535JO 1681.00 1522J0 1854.00 2085.00 1576 1827 2110 2367 2626 2890 3144 3392 12 x 12 x 15 12 x 12 x 20 12 x 12 x 20 12 x 16 20 12 x 16x20 12 x 16 x 20 16 x 16x20 16 x 16x20 HI MBBi BOI QHEfl SHUH BFj VL1 E*! r STEAM boller-bumer unit numbor FRA-504-SBCT) FR-A-505-SBfD FR-A-506-SB(D FR-A-507-SB(T) FR-A-508-SBfT) FR-A-509-SB(T) FRA-510-SB(T) FR-A-511-SB(T) greet Iwgwft output Mbh burner 0*capacity 384 472 560 648 736 824 912 1000 3.55 4.30 5.10 5.90 6.70 7.45 8.25 9.05 !!not It rating Mbh 4. ft team 288.1 354.1 420.1 486.1 552.1 618.2 684.2 750.2 1200 1475 1750 2025 2301 2576 2851 3126 Trade Price with standard equipment $1087JO 1204.00 1405.00 1535.00 1S85J0 1822.00 1954.00 2085.00 approx. hipping wight dnehlmnoy 1577 1828 2112 2369 2628 2892 3147 3395 12 x 12 x 15 12 x 12 x 20 12 x 12 x 20 12 x 16 x 20 12 x 16x20 12 x 16 x 20 16 x 16 x 20 16 x 16x20 -Nozzle sizes. Iph. furnished with the ebove units: FR.A-504. 2 1.75 SO* H: FR-A-505, 1 2.00 & 1 2.25 SO- H: FR-A-S06. 1 4.00 70- S (200 Psi*:) FR-A-507. 1 4 50 70- S (200 Psig); FR-A-SOS. 1 3.25 A 1 3.50 70- S: FR-A-509. 1 3.50 A 1 4.00 70" S; FR-A-510. 2 4.00 70* S; FR-A-511. 2 4.50 70- S. Suffix "T" danotas unit with openings in center uetiona for tanklaaa haatara. Start-up and on* year aervlct avallabla. Price on application. Standard equipment Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing cad cell, bracket and leads; R8184G light sensing primary control. Delayed oil valve except on model 92A-7240-D and 92A-7242-D oil burners. boiler-burner unit number FR-A-504 FR-A-505 FR-A-506, FR-A-507 FR-A-508 oil bunwr 92A-7240-D 92A-7242-D 95A-300-7468-D (200 Psig fuel unit) 96A-M-7498-D bolier-bumor unit number FR-A-509 FR-A-510, FR-A-511 Draft regulator Drain valve II bumtr 96A-M-7546-B 96A-M-7548-B Water No. 3 control set: ASME relief valve T822D thermostat Pressure and temperature L4080B Aquastat limit gauge control Nozzle (s) Steam: No. 1 control set: T822D thermostat PA404A Pressuretrol Nozzle(s) ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment Jacket extension: Jacket extension provides 25* enclosure in front for concealment of oil burner and controls. Approxi mate shipping weight 57 lbs. Specify on order. Added Trade Price ......................................................... *43.50 Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows: Trade Price each .......................................................... $4.25 For Factory Mutual Approval and Massachusetts code requirements, special electronic flame safeguard controls are available, with RA890 Protectorelay, W415A control panel (includes Q270A base and R488F switching relay), C7013A photocell. Delayed oil valve. oil heating unit bumir modal added Trado Price charge__ Control sets other than those included in Trade Price of FR-A-5 boiler-burner units will be furnished on order at the following added charges: Control St added charge Steam control set No. 2 Water control set No. 4 .................... Water control set No. 5 ................. `Water control set No. 5-Z .................. SI 4.80 11.65 23.75 27.75 FR-A-504 FR-A-505 FR-A-506. FR-A-507 FR-A-508 FR-A-509 FR-A-510. FR-A-511 92A-7240-L 92A-7242-L 95A-300-7468-L 96A-M-7498-L 96A-M-7546-L 96A-M-7548-L $162.00 162.00 142.00 162.00 155.00 155.00 (Add-on zona. Usa only with No. 5 Control Sat. Tha No. 5-Z control sat for circular zomnf on unit! with tankless htatars.) Ordering Examples: 1. Boiler-burner unit with standard equipment: 1 FR A 506 SB oil heating unit. 2. Boiier-burner unit for steam with optional equipment: 1 FR-A-509 SB T with No control set; 3 No. 530 tankless heaters; 1 3-heater manifold. See oaae 52 Page 29 HH-12 015' FLAME RETENTION BOILER-BURNER UNITS WATER AND STEAM jAMERICAN la STANDARD HYORONIC HEATING FR-A-7 FLAME RETENTION BOILER-BURNER UNITS The perfect combination of boiler and burner teamed for top performance develops lZbi% COj. Available with or less jacket. Tested and equipped for SO lbs. water working pressure. Onerstine controls furnished for 115 volt, 60 cycle povrer supply. WATER boiiar^umar unit numbtr FR-A-706-WO-B FR-A-707-WO-B FR-A-708-WO-B FR-A-709-WO-B FR-A-710-WO-B FR-A-711-WO-B FR-A-712-WO-B FR-A-713-WO-B FR-A-714-WO-B cmi lo-u8tpuftt Ubh 1-8-R bumor capacity *ph not l-8R rating Ubh ppiipcikn>gup4 factor nat rating q. ft orator unjackatad lackatod 'Trad# Prleo approa. Trada Prfca approa. with standard Shipping with standard shipping oquipmont woight oquipmont woight chlmnoy six# 1160 1376 1580 1812 2020 2228 2440 2720 3000 10.55 12.30 14.15 16.35 18.15 20.20 21.95 24.10 26.30 1008.7 1196.5 1373.9 1575.7 1756.5 1937.4 2121.7 2365.2 2608.7 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 6724 7976 9159 10504 11710 12916 14144 15768 17391 *2377.00 2621.00 3114.00 3332.00 3675.00 3911.00 4S03.00 4726.00 5054.00 4968 5626 6439 7223 7910 8558 9264 9950 10678 *2505.00 2768.00 3279.00 3614.00 3674.00 4126.00 4738.00 4976.00 5324.00 5144 5814 6750 7445 8149 8814 9534 10240 10988 16 x 16x30 16 x 20 x 35 16 x 20 x 35 20 x 20 x 40 20 X 20 x 45 20 x 20 x 55 20 x 24 x 60 20 x 24 x 70 24 x 24 x 80 STEAM bailor^umor unit numbar FR-A-706-SO-B FR-A-707-SO-B FR-A-708-SO-B FRA-709SO-B FR-A-710SO-B FR-A-7 U-SO-B FR-A-712-SO-B FR-A-713-SO-B FR-A-714-SO-B gross IwBaR output Ubh IkBkR bumor capacity gph not IbIbR rating Mbh sstoo-ofmt A unjackal ad Jackatiu piping A pickHJp factor Trada Prtea with standard OQuipmant approa. Trada Pries shipping with standard woight oquipmont approx. hipping woight chlmnoy sixa 1160 1376 1580 1812 2020 2228 2440 2720 3000 10.55 12.30 14.15 16.35 18.15 20.20 21.95 24.10 26.30 870.2 1041.6 1211.7 1403.6 1568.3 1729.8 1894.4 2111.8 2329.2 3626 4340 5049 5848 6535 7208 7893 8799 9705 1.333 1.321 1.304 1.291 1.288 1.288 1.288 1.288 1.288 *2377.00 2621.00 3114.00 3332.00 3675.00 3911.00 4503.00 4725.00 5054.00 4970 5629 6441 7228 7915 8560 9266 9952 10680 *2505.00 2768.00 3279.00 3514.00 3574.00 4128.00 4738.00 4979.00 5324.00 5146 5817 6752 7450 8154 8816 9536 10242 10990 16 x 16x30 16 x 20 x 35 16x20x35 20 x 20 x 40 20 x 20 x 45 20 x 20 x 55 20 x 24 x 60 20 x 24 x 70 24 x 24 x 80 *Amaricar>Standard should bt consulted before selecting on FR boiler-burner unit for installations having unusual piping and pick-up requirements. eNoie sues. gph. furnished with the above units: FR-A-706. 1 5.00 & 1 5.50 *0* S: FR-A-707. 2 6.00 60* S: FRA-708. 1 2.00 A 2 6.00 90* S: FR-A-709. 1 3.00 fc 2 6.50 90* S: FR-A-710. 2 9.00 70* S; FR-A-711. 2 10.00 70* S; FR-A-712. 2 6.00 4 1 10.00 80* S; FR-A-713. 2 6.00 & 1 12.00 80* S. FR-A-714 18006 2 9 00 60 S. Surt-up and one year service available. Price on application. Standard equipment: Pedestal mounted oil burner with 2-stege fuel unit; on 96A-M-7543-B and 9708111-B burners, factory installed cad cell, bracket and leads: R8184B light sensing primary control. On 96A-T burners, RA890 Protectorelav and Q270A base, C7013A photocell; on 97A Hi-Lo and 98A Hi-Lo burners, R4150A Flame Safe guard control -- provides prepurge and postpurge, Q520A base, C7013A photocell. Delayed oil valve (2 with 96-A-T). Delayed and instantaneous valves with 97A Hi-Lo and 98A Hi-Lo. bil.reumr unit number oil bumor standard motor valtaga FR-A-706, FR-A-707 FR-A-708 FRA-709 FR-A-710. FR-A-711 FR-A-712. FR-A-713 FR-A-714 12M cast iron bass on all units, 96A-M-7543-B 115/60/1 96A-T-7935-K 115/60/1 96A-T-7937-K 115/60/1 970-8111-B 115/60/1 97A Hi-Lo-7673-E 98A Hi-Lo-7773-E 230/60/1 230/60/1 In addition. I" high stoat padastal basa is Turnishad with S through 14 soction units. Draft regulator. Water L4080B Aquastat limit control Steam: PA404A Pressuretrol Nozzles Nozzles ASME relief valve ASME safety valve Pressure and temperature eauge Steam gauge Optional equipment: See page 33. Gauge glass with trimmings Combustion chambar not furnished. See Installation-Operation end Maintenance Manual for combustion chambers required far FR-A-7 boiler-burner unite. Nete: For Optional Electronic Flame Safeguard Control Equipment, See Page 33.* 1 2 Ordering Eiampies: 1. Boiler-burner unit for steam jacketed with standard equipment 1 FR-A-710-S0-B boiler.burner unit 2. Boiler-burner unit for water less ticket with optional equipment: 1 FM-707-W0-B boiler-burner unit with electronic 'leme safeguard controls to meet Factory Mutual Approval. HH-12 w See sage 52 Page 30 01547 dAMERi'..' STANDAKL HYDRONIC HEATING OIL FIRED BOILERS WATER AND STEAM WATER A-5 OIL FIRED BOILERS This boiler is designed for large residences, apartment and commercial buildings. Tested and equipped for 50 lbs. water working pressure. boiler number grots raJt output Mbh IbBmR burner capadty tP net ratine Mbit net rating eft water ^ Trade Price For Built-in Water Heaters , Steam and Wate Bailers, see page 28. approx. shipping weight A-504-W(T) A-505-WfT) A-506-W(T) A-507-W(T) A-508-W(T) A-509-W(T) A-510-W(T) A-511-W(T) 261 2.55 227.0 1513 * 789.00 346 3.30 300.9 2006 900.00 426 4.00 370.4 2469 1032.00 508 4.75 441.7 2944 588 5.55 511.3 3408 668 6.30 580.9 3872 1103.00 1281.00 1412.00 748 7.00 650.4 4336 830 7.65 721.7 4811 1542.00 1875.00 1518 1770 2025 2282 2539 2794 3050 3298 chimney Ue 8x 12 x 15 8 x 12 x 20 12 x 12x20 12 x 12 x 20 12 x 16x25 12 x 16x25 12 x 16x25 16 x 16x30 STEAM beiler number A-504-SfD A-505S(T) A-506-S(T) A-507-SfO A-508-S(T) A-509-S(T) A-510-Sm A-511-S(T) gross IbBbR output Mbh 261 346 426 508 588 668 748 830 IsBobR burner capacity CPh 2.55 3.30 4.00 4.75 5.55 6.30 7.00 7.65 nat IsBiift rating Mbh oft staam 195.8 259.6 319.6 816 1082 1332 381.1 441.1 501.1 561.1 622.7 1588 1838 2088 2338 2594 ^TTrsde Prtca 8 789.00 906.00 1032.00 1163.00 1288.00 1412.00 1542.00 1875.00 approx. shipping weight 1519 1771 2027 2284 2541 2796 3052 3300 chimney sUe 8 x12 x15 8 x 12 x 20 12x12x20 12 x 12x20 12x16x25 12 x 16x25 12 x 16x25 16 x 16x30 Suffix "T" denote* boiler with openings in canter sections for tankless heaters. Standard equipment: Optional equipment: Water ASME relief valve Pressure and temperature gauge Drain valve Cover plate required to clcse unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows: Trade Price each .. *4.25 Steam: ASME safety valve Steam gauge Gauge glass with trimmings Drain valve Zone valve packages are available for water boilers. For details and prices, see page 34. Oil Burners available on special order.............................................. Price on Application Orderinf Examples: 1. Boiler only lor steam with standard equipment: 1 A-507 S boiler. 2. Boile' only for water with optional equipment: 1 A 506-W boiler with jacket extension Jacket extension: Specify on order and add *44.00 to Trade Price of boiler or unit. Jacket extension provides 25' en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbs. A-5 OPTIONAL EQUIPMENT HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit number A-504 A-505 A-506 A-507. A-508 A-509. A-510, A-511 "W See page 52 Hast Lld-O-Retor modal No. Inciudad 14A 15A 15AA 16-A 17A maximum firing rata gallons par hour 2.55 3.30 4.00 5.55 7.65 Page 31 Trada Prtca *40.00 40.00 50.00 50.00 58.00 approx. shipping weight 158 163 176 180 200 HH-12 01548 Oil FIRED BOILERS WATtl AND steam dAMtKILMiN STANDARD HYDRONIC HEATING A-7 OIL FIRED BOILERS Ideal for commercial and iiuluaUiai buildings. Available with or less jacket. Tested and equipped Tor SO lbs. water working pressure. WATER boiler number grots ImBmft lBft burner output capacity Mbfi gph net l-B-ft rating Mbh plains* picS-up factor net umacketed ratine 4. ft watar epprea? Trsdt Price shipping weight jacketed Trade Price went hipping waifht chimney size A-705-WO A-706-WO A-707-WO A-70B-WO A-709-WO A-710-WO A-711-WO A-712-WO A-713-WO A-714-WO 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 21.45 23.20 753.0 880.0 1040.0 1196.5 1365.2 1530.4 1700.9 1867.8 2034.8 2201.7 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 5020 5866 6933 7978 9101 10202 11339 12452 13565 14678 (1826.00 1092.00 2239.00 2474.00 2601.00 2917.00 3162.00 33444)0 3566.00 3773.00 4186 4787 5445 6029 6669 7330 7956 8616 9278 9944 (10(7.00 2121.00 23(4410 2836.00 2873.00 3118.00 3370.00 3570.00 3819.00 4041.00 4358 16 x 16x28 4963 16 x 16 x 30 5633 16 x 20 x 36 6240 16x20x42 6891 16 x 20 x 45 7569 20 x 20 x 50 8212 20 x 20 x 55 8886 20 x 20 x 60 9568 20 x 24 x 70 10254 20 x 24 x 80 hH-12 STEAM boiler number gross IwBbR lb-Bur>neRr output capacity Mbh BP* net l sslvfl rating unjacketed Mbh sq ft taam piping 4 pick-up Trade Price factor approx. shipping weight Jacketed approx. Trade Price shipping weight chimney sue A-705-SO A-706-SO A-707-SO A-708-SO A-709-SO A-710-SO A-711SO A-712-SO A-713SO A-714-SO 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 21.45 23.20 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 1.333 1.333 1.333 1.321 1.305 1.293 1.288 1.288 1.288 1.288 (1826.001 1892.001 2239.001 2474.001 2001.001 2917.001 3152.00' 3344.00' 3566.00 3773.00 4187 4788 5447 6030 6673 7334 7957 8617 9279 9945 $1937.00 2121.00 2354.00 2630.00 2873.00 3115.00 33704)0 3579.00 3819.00 4041.00 4359 16 x 16x28 4964 16 x 16x30 5635 16 x 20 x 36 6241 16 x 20 x 42 6895 16 x 20 x 45 7573 20 x 20 x 50 8213 20 x 20 x 55 8887 20 x 20 x 60 9569 20 x 24 x 70 10255 20 x 24 x 80 * Th net l = B = R ratings shown art based on piping and pick-up allowancas listed in tha column next to tha ratings. AmericanStandard should bo consulted before selecting a boilar for installations having unusual piping and pick-up requirements. Standard equipment: Water ASME relief valve Pressure and temperature gauge Steam: ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment: Steel pedestal bases for installation under the regularly furnished 12 inch cast iron base for greater base heights are available on order at the fol lowing added charges: ix1.n liH bo height WTroO. 5 thru 7 8 thru 14 8" S 63.00 10" 102.00 If steel pedestal baae is not used, consideration should be given to the use of brick or masonry base as required. For Additional Optional Equipment, See page 33. Combustion chombor not furnished. Sou Insfallation-Oporution end Mointononco Manual for combuition chamber? roqrrlroj Sr a-7 bailor?.* 1 2 Ordering Eisnpies: 1. Boiler only with jacket (or steim with optional equipment 1 A-711-S0 boiler jacketed with steel pedestal base 2. Boiler only ur,r;keted for water with standard afliiinnmrt 1 A-/06-W0 limacketed Note: Be sure to specify on order litter "0" after "S" or "W" or coal fired boiler will be supplied. Page 32 01549 fSIAMERICAN caSTANDARD HYDRONIC HEATING oil burners OPTIONAL EQUIPMENT A-7 AND FR-A-7 OPTIONAL EQUIPMENT ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT ror Factory Mutual Approval requirements, special ,,1'Ctronic flame safeguard controls are available with FA890 Protectorelay, W415A control panel (includes J'TOA base and R488F switching relay),C7013A photocell, p'laycd oil valve. (2 with 96A-T-7935-R and 96A-T-7937-R.) Oil burners to meet Massachusetts Code requirements -- Price on application. boJIMumGr unit FR-A-706. FR A-707 FR-A-708 FR-A-709 FR-A-710, FR-A-711 bumGf modal 96A-M-7543-L 96A-T-7935 R 96A-T-7937-R 970-8111-R adtfod TradG Prica charg** $147.00 49.00 49.00 147.00 NOTE: R41SOA Flame Safeguard contra* on 97A HFLe and 9SA HMj burners used with FR.A-712. FR-A-713 and FR-A-714 units masts Factory Mutual Approval and Massachusetts coda requirements. McDonnell & Miller low water cut-off and feeder combinations or low water cut-offs are available for FR-A-7 and A-7 steam units and boilers at added Trade Prices as follows: unit er boiler no. MAM no. AdM Trada Prica FR-A-706: A-705 thru A-707 FR-A-707 thru FR-A-713 A-708 thru A-714 FR-A-714 47-2 51-2 51-S-2 77.00 100.00 112.00 A-7 and FR-A-7 369 27.00 Provision for special equaliser tapping (1* I.P.S. maximum) for bottom connection of 61-2 or 51-S-2 is located 12 Va inches below water line on front section. Other temperature controls are shown on page 36. FR-A-7 and A-7 external water heater tappings: two 1' tappings will be furnished on center sections for water boilers only. Lower tapping 23" from bottom of section. Center to center dimension between tappings is 27 H". If desired specify on order and add $12.50 per "C" section to Trade Price of boiler. DH OIL BURNERS The DH burner is designed and built to exacting standards for dependable and trouble free operation. The quiet motor and reliable controls are regularly furnished for 115 volt, 60 cycle power supply. tntd*! wwmbGr DH-5 DH-6 DH-15 DH-23 (GGGcIfy fGl. pm hGr .55 3.00 65 - 3.00 .65 - 3.00 .65 3.00 air hfW 4\mrk. Unftk GIGWGtiGf Trod# Wet wfdl GUit WKlwdGt fattGT |AtG(lGd cad <ofl wHb GG. 1 Gf GG. J CGAhGl *Gt GGd pfimorr (OMrol with pHogget (GGtnH GGd Mill# Igm tad call 45 sling 4 8 / pedestal) 4 15 < , r > 4 23 ( flange ) $164.00 164.00 166.00 169.00 _ $145.00 147.00 149.00 * $111.00 116.00 118.00 ee. *Meweight ridl cmmI BG 55 60 64 68 t<r bum*r unit oil bumtr control* ip'TI BDH-5 3 packaged unit dh-5 (Primary control, cad cell and )controls, except thermostat, (factory installed. I Draft regulator. 4 3 Boiler unit DH-5 (Primary control, controls. < Cad cell factory installed. I Draft regulator. For A-3 units pressure ring is packed with DH-S burner. *1*11-5 burners for AP(T) packaged units furnished with ''iractory turbulator and are not interchangeable with v,h*r DH-5 models. `cttiet with strainers for Oh burners used wltn boller-Burner units: nlid cone 60" with AP(T), solid cone 70' with A-3 packor boiler-burner units. J ` burners listed in this Price Book are approved by the i- tlonaI Board of Fire Underwriters, comply with U. S. `1H:!!}TTlent Commercial Standard CS-75, and are for use . No i or No. 2 fueloil. -ktiacmes of oil burners using No. 1 or No. 2 fueloil are for i.,.1"ations at sea level and at elevations up to 1,000 feet. # _)"ce 4% for each additional 1,000 feet above sea level, -duct from shipping weight of burner with control set: jess cortrol set 3 lbs. less control set and primary control 9 lbs. Disc-turbulator combina tions for DH oil burner are as follows: firing rata no. fph R1 .55-1.JO R2 1.00-1.85 1 .65-1.10 2 .90-1.75 3 1.80-2.50 4 2.35-3.00 Selection of nozzle: firing rata nozzla pray .55 to 1.25 60*-70* hollow or solid above 1.25 60*-70' solid The correct disc-turbulator combination is furnished in stalled in the DH burner for nozzle size specified on order. Two-stage fuel unit is available for DH oil burners at added Trade Price $6.50 Controls and control sets are shown on page 35. OfQGfing Examplaa: 1. Oil Burner 1 DH-5 oil burner with No. 5 control Mt *nd 2.SO gph 70 solid nozzlG for A-37M-WBT boiir-bufn*r unit, t. On' 3ui-n#r >-'-*3 oil burner with No. 3 control 1.50 gph 60 solid nozzla, with pGdtltal. s Page 52 Page 33 HH-12 01550 ZONE VALVE PACKAGE COMFORT COMPUTER Illustrated is Comfort Computer-Zone Valve Package _ AMERICAN STANDARD HYORONIC HEATING COMFORT COMPUTER MODEL 370(R) The American Standard exclusive and unique Comfort Computer is a solid state control which modulates the boiler water temperature in proportion to the number and length of heat demands. This control and zone valve pack age is especially designed for use with American Standard Boilers. Bene fits received are: improved comfort balance in living areas; reduction of wall streaking and expansion noises; and increased operating efficiency. The Comfort Computer controls the operation of the burner to slow down the response of the boiler temperature to calls for heat by a zone thermo stat. The control optimizes boiler water temperature and will not permit introduction of excessively hot water temperature to a zone. This control permits only those boiler water temperatures actually required by the heating system, yet permits high water temperatures during cold weather or during "pick-up" periods. The Comfort Computer is designed for Gas Boilers without tankless heaters; and is available in two models, the 370 and the 370R. The model 370 is for use with installed boilers using a solenoid gas valve only; the 370R is for use with all modern gas fired hydronic heating systems. Trade Prices are as follows: 370 ......................... $42.00 370R $54.00 COMFORT COMPUTER - ZONE VALVE PACKAGE The Comfort Computer is available combined with the zone valve package factory mounted and wired. When ordering the complete package the designation of the zone valve package is added to that of the Comfort Computer, Trade Prices are: 370R-2Z- $141.00 370R-3Z- $169.00 370R-4Z-$211.00 HYDRONIC ZONE VALVE PACKAGES No. Z-2 Package for 2 Zorns No. Z-3 Package for 3 Zonal No. Z-4 Package for 4 Zonal 1 T822D thermostat 2 T822D thermostats 3 T822D thermostats 2 V8043F zone valves soldered to 3 V8043F %" zone valves soldered to 4 V8043F \" zone valves soldered to manifold manifold manifold Less transformer Less transformer With transformer Trade Price ........................... $87.00 Trade Price ....... .................. $118.00 Trade Price .............................$187.00 Each zone valve package consists of 2, 3, or 4 Honeywell zone valves soldered to manifold with 114" NPT inlet. Each zone valve is factory wired to low voltage leads for transformer and all end (auxiliary) switches are wired in parallel with a pre-wired harness. On-the-job wiring re quires 115 volt line to transformer, low voltage connections to circulator control, and low voltage wiii -; to each thermostat. If H" system piping is used, Sili nominal copper to copper flush bushing can be soldered to any or all of the \ " zone valves on the manifold. Flush bushing not furnished. One less thermostat is furnished than the number of zone valves per package. An additional thermostat is required when zone valve package is used on boiler furnished less thermostat. 40 VA transformer is not required when control L3l4t(G or R8226B with power for 3 zone valves, is supplied with boiler. If 40 VA transformer is wanted with No. 2-2 or No. Z-3 Packages, specify on order and add to the above Zone Valve Pack age prices. ............................................................................................................................. .T Trade Price each $3.30 Honeywell V8043F " Zone Valve sold separately HH-12 Page 34 Trade Price each $23.00 01551 ^AMERICAN IS STANDARD HYDRONIC HEATING CONTROL SETS, CONTROLS Centre: Bet CONTROL SETS FOR BOILER-BURNER UNITS content* of control set control for numbor description add to Trado Prieo of oil burner with bts'e control oot no. 1 steam no. 2 steam boiler without domestic hot water boiler with year-round domestic hot water, tankless heater no. 3 gravity water no. 4 forced water boiler without domestic hot water, immersion control boiler without domestic hot water no. 5 A-3, A-5. FR-A-5 units only with year-round forced water domestic hot water T822D PA404A T822D PA404A L4006A T822D L4080B T822D L4081B T822D L8124C no. 5-Z forced water A-3. A-5. FR-A-5 units only. (1 no. 5-Z set is required for each zone in addition to the first zone which is controlled by the no. 5 control set or equivalent.) T822D R845A Thermostat Pressuretrol Thermostat Pressuretrol Aquastat operating control Thermostat Aquastat limit control Thermostat Aquastat limit and circulator control Thermostat Aquastat limit reverse and operating control, circulator relay Thermostat Relay $14.90 $11.65 $23.75 $27.75 numbor description T822D TS822A T832A T852A L4006A L4006E 14081B L40B0D L4080B L6006A thermostat, adjustable heater 0.18 to 0.8 amp. thermostat, millivolt thermostat, low voltage, manual turndown thermostat, electric clock Aquastat operating control Aquastat operating control: locks out on high limit setting; manual reset Aquastat limit and circulator control Aouastat limit control Aquastat limit control Aquastat operating and circulator L8124C L8124B L8124E L404C L604A L8148E L8148G Aquastat limit, reverse and operating control, circulator relay line voltage burner control, horizontal case for pas or oil millivolt burner circuit for gas with manual-auto switch, vertical case low voltage burner circuit for gas. vertical case. Power for 2 zone valves Aquastat-relay combination, high limit and line voltage circulator control. horizontal case: Pressuretrol w/man. reset SPDT operating controller low voltage burner control for gas. Power for 2 zone valves. millivolt burner control for gas. Power for 3 zone valves. CONTROLS Met $ 7.25 7.25 26.80 42.50 14.90 17.10 number PA404A RA89A RA832A R845A R8226B R8182D 22.15 ii.as 11.25 R8182E 15.80 R8182F 34.25 31.15 33.70 R8184G 29.90 25.90 23.70 120320 description Tredo Price Pressuretrol relay, SPST relay, DPST relay, DPST Transformer and circulator relay Aquastat-relay combination, high and low limit; providing room thermostat control of circulator: light sensing primary control, less cad cell; safety switch timing 70 seconds. For use with tankless. Aquastat combination, high limit; providing room thermostat control of circulator: light sensing primary control, less cad cell: safety switch timing 70 seconds. For use less tankless. Aquastat combination, high limit: providing room thermostat control of burner and boiler water temperature control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless. light sensing primary control, less cad cell: control numbor safety switch timing-seconds gph R8184G1005 60 R8184G1021 30 R8184G1013 15 cadmium sulfide cell only 3 3-7 7-20 $17.10 16.25 20.50 20.50 11.25 57.25 53.00 47.25 31.80 34.90 39.00 2.30 23.70 *To substitute T852A for T822D Thermostat; specify on order control set with suffix "B" and .odd to trade p>".ce different1; above. See page 52 AccMlcnes ina uorrrol, i^iucec in this price Book ere lor use m conjunction with Americen-Slenflerp proCgcts. Page 35 HH-12 01552 STOKER FIRED BOILERS WATU AND STEAM d AMERICAN STANDARD HYORONIC HEATING A-7 STOKER FIRED BOILERS The i-.-r.dnrd for commercial and industrial building .priicauun. A vaiiabie with or less jacket. Tested and equipped for 50 lbs. water working pressure. WATER bailor number A-705-WC A-706-WC A-707-WC A-708-WC A-709-WC A-710-WC A-711-WC A-712-WC A-713-WC A-714-WC iron IbIkR output Mbh 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 I.BbR burner capacity tbs./hr. 95 111 131 151 172 194 215 236 257 278 A not lBR ratine Mbh 753.0 880.0 1040.0 1196.5 1365.2 1530.4 1700.9 1867.8 2034.8 2201.7 piping 4 pick*up factor 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 not rating sq. ft water 5020 5866 6933 7978 9101 10202 11339 12452 13565 14678 unlaefcotsd Trad# Price appro*. shipping weight 4 n lackatad appro*. shipping weight chimney siza *1826.00 1092.00 2239.00 2474.00 2691.00 2917.00 3152.00 3344.00 3566.00 3770.00 4120 4775 5436 6017 6693 7370 7972 8610 9323 10013 SI 937.00 2121.00 2304.00 2638.00 2073.00 3115.00 3370.00 3579.00 3019.00 4041.00 4292 4950 5619 6226 6908 7589 8233 8908 9593 10283 16 x 16 x 28 16 x 16 x 30 16 x 20 x 36 16x20x42 16 x 20 x 45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 STEAM boiler number A-705-SC A-706-SC A-707SC A-708-SC A-709-SC A-710-SC A-711-SC A-712-SC A-713-SC A-714-SC grotl l=BsR output Mbh 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 IsBsR burner capacity Ibt./hr. 95 111 131 151 172 194 215 236 257 278 net IsBsR rat "C A Mbh sstqe.afmt. piping 4 pick-up factor unjacketed Jacketed Trade Price approx. shipping weight Trade Price appro*. shipping weight chimney sUs 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 1.333 1.333 1.333 1.321 1.305 1.293 1.288 1.288 1.288 1.288 $1020.00 1992.00 2239.00 2474.00 2691.00 2917.00 3152.00 3344.00 3560.00 3770.00 4121 4776 5438 6018 6697 7374 7973 8611 9324 10014 $1937.00 2121.00 2304.00 2630.00 2073.00 3115.00 3370.00 3570.00 3019.00 4041.00 4293 4951 5621 6227 6912 7593 8234 8909 9594 10284 16 x 16x28 16 x 16x30 16 x 20 x 36 16 x 20 x 42 16 x 20 x 45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 * The net l = S=rR ratings ihawn ore based on piping and pick-up allowances listed in the column next to the ratings. Americon-Standard should be consulted before selecting o boiler for installations having unusual piping and pick-up requirements. Standard equipment: Water: ASME relief valve Pressure and temperature gauge Steam: ASME safety valve Steam gauge Gauge glass with trimmings Optional equipment: Steel pedestal bases for installation under the regularly furnished 12 inch cast iron base for greater base heights are available on order at the following added charges: action sico 5 thru 7 8 thru 14 basa height 8" 10" "W Trade Price $ 63.00 102.00 If steel pedestal base is not used, consideration should be given to the use of brick or masonry base as required. For additional optional equipment see page 33. Ordering CsompU: Slokr boiler for woior with jocket with optional equipment: 1 A-70B-WC |Ock*td boii*r, with stool pedestal boso. HH*1 2 Page 36 01553 FamI AMtKIt-AIN LSJ STANDARD HYDRONIC HEATING A-7 HAND FIRED BOILERS Jacketed and unjacketed Tested and equipped for 50 lbs. water working pressure HAND FIRED BOILERS WATER AND STEAM WATER Mlr numMr A-705-W A-706-W A-707-W A-708-W A-709-W A-710W A-711-W A-712-W lgfBOSSR output Mbh 1122 1298 1510 1708 1910 2108 2288 2456 not tmBmH rating Mbh 625.4 744.3 894.0 1042.1 1202.0 1363.5 1518.2 1667.3 A piping 4 picknip factor 1.794 1.744 1.689 1.639 1.589 1.546 1.507 1.473 not rating op. ft wrator 4169 4962 5960 6947 8013 9090 10122 11115 unfackotod Trad* Price IPP1 chipping wight (2011.00 2108.00 2434.00 2005.00 2872.00 3009.00 3304.00 3477.00 4546 5270 6025 6679 7508 8170 8848 9565 Jacket** Trad* Mea approx. chipping wight (2122.00 2310.00 25003)0 2049.00 305340 32894)0 3521.00 37114)0 4718 5545 6208 6888 7643 8389 9109 9863 chimney tlx* 16 X 16x40 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 65 20 x 24 x 70 24 x 24 x 75 STEAM b*ll*r number A-705-S A-706-S A-707-S A-708-S A-709-S A-710-S A-711-S A-712-S grot* IsBbR output Mbh 1122 1298 1510 1708 1910 2108 2288 2456 Mbh net IbBbR ap. ft steam A piping 4 pick-up factor 625.4 744.3 894.0 1042.1 1202.0 1363.5 1518.2 1667.3 2606 3101 3725 4342 5008 5681 6326 6947 1.794 1.744 1.689 1.639 1.589 1.546 1.507 1.473 unfackotod Trade Rrica approx. shipping wight $2011.00 2185.00 2434.00 2005.00 2872.00 3009.00 3304.00 3477.00 . 4561 5285 6036 6692 7521 8183 8861 9582 Jacketed Trade Price approx. chipping weight (2122.00 2316.00 2500.00 2149.00 3053.00 3260.00 3521.00 3711.00 4733 5460 6219 6901 7656 8402 9122 9880 chimney size 16 x 16x40 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 65 20 x 24 x 70 24 x 24 x 75 * The net l=B=R ratines shown are based on piping and pick-up allowances listed in the column nest to the ratings. American Standard should be consulted before selecting e boiler for installations having unusual piping and pick up requirements. Standard equipment: Water ASME relief valve Pressure and temperature gauge Automatic damper regulator Firing tools Steam: ASME safety valve Steam gauge Gauge glass with trimmings Automatic damper regulator Firing tools Ordering Example: Hand fired boiler for water with jacket with standard equipment: 1 A-706-W jacketed boiler See page 52 Page 37 `-12 01554 HYDRONIC ASSEMBLING TOOLS fSl AMERICAN taSTANDARD HYDRONIC HEATING PACKAGED HYDRAULIC ASSEMBLING TOOL: All necessary parts to assemble any American-Standard sectional boiler, except Ion? tie rods, are shipped in one packing case; the long tie rods are furnished in their own wooden box. Total weight approximately 250 lbs. ~W Trade Price - $400.00 RAOIANTRIM ASSEMBLY CLAMP: This tool is designed to draw Radiantrim cast iron baseboard sub-assembled panels or sections together with ease as per instructions included. Order through your American-Standard distributor. W Trade Price each - $10.75 HEATRIM COPPER TUBE BENDING TOOL: This tool is specifically designed to bend riser tube connections for Model R Heatrim baseboard panels. Eliminates costly copper fittings. Com plete instructions for tool use included. Trade Price each -- $14.55 HEATRIM RISER HOLE TEMPLATE: This tool accurately and quickly lo cates riser hole locations for Model R Heatrim panels. Consists of template (two pieces I. 8 ft. steel tape and com plete instructions. yr Trade Price each -- $2.90 ALUMINUM NIPPLE-SETTING-HAMMER: --consists of a 2 lb. 2'/i" diameter aluminum head and a 14" long hard wood handle. The aluminum head will not damage the nipple edges and per mits the heavy blows necessary to set nipples to the recommended depth quickly. Trade Price each -- $4.75 SECTION BUMPING BLOCK: -- made of a 6" x 6" x 18" hardwood block with a convenient steel handle for swinging the tool. Its purpose is to bump a sec tion onto the pre-set nipples of the previous section to the recommended depth, prior to pulling the section up, with one or two blows without damage to the section. Trade Price each - $14.00 HH-12 yr See cage 52 Page 38 01555 /^AMERICAN ba STANDARD HYDRONIC HEATING ELECTRA II PACKAGED ElECTRO-HYDRONIC BOILERS Completely packaged with deluxe two-toned brown and beige jacket. Pre-wired for 240 volt, three wire, 60 cycle, single phase service. Designed and equipped with CCnfTols for forced circulation. Tested and equipped for 30 lbs. water working pressure. PACKAGED BOILERS electric WATER ctccTsic cnrstt ioiics *itk istksu uhiT coereoi E38074________ NO 0000000 WATER ONLY pockeged unit number EP-7 EP-10 EP-14 EP-17 EP-20 output watts 2,000 3.000 4,000 5.000 6.000 output btuh 6.826 10.236 13,648 17,060 20,472 amps 9 240 volts 8.34 12.50 16.65 20.81 25.00 W Trade Price wMi standard equipment $21240 212.00 212.00 212.00 212.00 approx. shipping weight 49 49 49 49 49 Ordennf Example IP Pockoged Boiler with itandord equipment: 1 EP-14 boiler See page 52 Standard equipment T822D thermostat Circulator with piping Drain valve ASME relief valve Pressure and temperature gauge Expansion tank (diaphragm type) L4080D immersion limit control J- W. Hobbs M4440 low pressure switch Automatic air vent a Output ratings based on 240 volts. Reduce output ratings for other voltages as follows: 230 volts, 8%; 220 volts, 16%; 208 volts, 25%. All electrical controls, circulator, expansion tank, pressure and tempera ture gauge, automatic air vent, and drain valve, are factory installed and wired. Thermostat and relief valve shipped in accessory bag fastened inside boiler carton. Zone valve packages are available for water boilers. For details and prices, see page 34. Page 39 01556 HH-12 PACKAGED BOILERS ELECTRIC WATER . -- ! AMERICAN kza STANDARD HTDRONIC HEATING "ELECTRA" EP PACKAGED tLtCIRO-HYDRONIC BOILER For the ultimate in modem electric heating, choose the "Electra." a completely assembled, pre-wired, hydronic heating east iron boiler. Designed for ultra-safe operation and equipped with controls for forced circulation. Attractive two-toned brown and beige jacket completely conceals all componenta including the circulating pump and expansion tank. Rugged boiler shell is tested and equipped for 30 lbs. water working pressure and unit is ar ranged for 2*0 volt, three wire, 60 cycle, single phase service. WATER pacupi Mriar awnBtr tf tenants BtftRVt watts Mrttvt strj. Stull EP-34 EP-51 EP-68 EP-82 2 3 4 5 10,000 15.000 20.000 24.000 34,130 51.195 68.260 81.912 41.7 62.4 83.2 100.0 ELECTRIC CENTRAL HEATING SOUR mm wnetAt unit carnm. . 38076_ _ _ _ _ _ _ _ No. ooo ooo , Tri ft** vttn staniartf naifmt 8428.00 440.00 4583)0 474.00 Msni. tfcteatnt waiftt 98 99 100 102 Standard equipment T822D thermostat AT72D low voltage transformer RSIS* sequencing control L4008J adjustable immersion type limit control Allen-Bradley 836CP11-HKAZS High pressure switch with EP-68 and EP-82 only J. W. Hobbs M*4*0 Low pressure switch 1 Li' circulator Expansion tank (diaphragm type) Automatic air vent ASME Relief valve Pressure and temperature gauge Drain valve OrSering frimplr EP Packaged Boiler with standard equipment: 1 EP-68 boiler HH-12 See :a;e 52 Not*; EP Electric Boilers are shipped with jacket and all controls (except thermostat and relief valve) factory installed and wired. Circulator and expan sion tank are factory installed and enclosed in the jacket. Thermostat, relief valve and nipple, and circulator flange and gasket shipped in accessory bag fastened inside boiler carton. Output ratings based on 240 volts. Reduce output ratings for other voltages as follows: 230 volts, 8%; 220 volts, 16%; 208 volts, 25%. Optional equipment Sequencer Package: Available for field installation on EP-68 and EP-82 Boilers in addition to regularly furnished sequencing relay. Package contains all necessary equipment and instructions for the installation of one (EP-68) or two (EP-82) 24A11-4 Sequencer(s) which will provide a 45 second current delay between the third and fourth elements of the EP-68 or between the third, fourth and fifth elements of the EP-82. Standard R8154 relay provides a 1 /120th of a second (L4 cycle) current delay between each element. innninhcup NyinMMn EP-68 EP-82 312.24 23.60 Nt: Zone valve packages are available for water boilers. For details and prices, see page 34. Page 40 01557 fWIAMtKILAN ISiSTANDARD HYDRONIC HEATING HEATRIAA PANELS MODEL R HEATRIM PANELS SEE CURRENT^L'TCRATURe FOR APPROVED i=d=R HOT WATER RATINGS " (For Yt" Model ft-750 and Vi~ Model R-500 Panels) DESCRIPTION numfrf jMckj(*d Pf MODEL R-750-A COMPLETE ASSEMBLED UNITS (Single Pack) includes 1 each of front and oack panel, element, damper, necessary support brackets, slide cradles and 1 se joining pieces. Finished with white prime paint All factory assembled. Bos Color Coded-Rad Drdtriif Example 1-Doi R-750-A4 R-750-A2 R-750-A3 R-750-A4 R-750-A5 R-750-A6 R-750-A7 R-750A8 per lineal foot 2 ft. length 3 ft. length 4 ft. length 5 ft length 6 ft. length 7 ft. length 8 ft. length Tr*d Prtcm pprox. Mpptnf w*ctrt S 2.09 4.18 6.27 8.36 10.45 12.54 14.63 16.72 5 7 9 12 13 16 18 MOOEL R-500-A COMPLETE ASSEMBLED UNITS (Single Pack) includes 1 each of front and back panel, Vi" element damper, necessary support brackets, slide cradles and 1 se joining pieces. Finished with white prime paint. All factory assembled. Bos Color Coded--Green Ordering Eiimpli: 1--box R-500-A3 R-500-A2 R-500-A3 R-500-A4 R-500-A5 R-500-A6 R-500-A7 R-500-A8 per lineal foot 2 ft. length 3 ft length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 1.98 3.97 5.95 7.9* 9.92 11.91 13.89 15.88 5 7 9 11 14 15 18 MODEL R ENCLOSURE ONLYASSEMBLED (Single Pack) includes 1 each of front and back panel, damper, necessary support brackets, slide cradles and 1 set joining pieces. Finished with white prime paint All factory assembled. 8ox Color Coded--Black Ordering Example: 1-box R-3-A R-3-A R-4-A R-5-A R-6-A R-7-A R-8-A R-10-A R-12-A MOOEL R ENCLOSURES ONLYUNASSEMBLED (Bulk Pack) includes 3 sets of front and back panels, dampers with clips, necessary support brackets, slide cradles and 2 sets of joining pieces. Finished with white prime paint. Unassembled. Box Color Coded-Blue Oreermg Example: 1-box R-5-B R-3-B R-4-B R-5-B R-6-B R-7-B R8B R-10-B R-12B per lineal foot 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 10 ft. length 12 ft. length 1.02 3.06 4.07 5.09 6.11 7.13 8.15 10.19 12.22 per lineal foot three 3' lengths thre.: 4' lengths three 5' lengths three 6' lengths three 7' lengths three 8' lengths three 10' lengths three 12' lengths .91 8.22 10.96 13.70 16.44 19.18 21.92 27.41 32.89 6 8 10 11 13 15 17 19 16 21 26 30 35 40 48 58 For comparative and estimating purposes only. w See page 52 Page 41 HH-12 01558 HEATRIM ELEMENTS AND ACCESSORIES ^AMERICAN LsiSTANDARD HVDRONIC HEATING ------ MODEL R HEATRIM ELEMENTS AND ACCESSORIES Plffilllliiii,] DESCRIPTION E-750 (%" tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths. Ordering Esimplt.- 1-bundle E-750-3 ordering number E-750-3 E-750-4 E-750-5 E-750-6 E-750-7 E-750-8 packaged per per lineal foot Trade Price $ 1.12 approx. shipping weight six 3' lengths six 4' lengths six 5' lengths six 6' lengths six 7' lengths six 8" lengths 20.22 26.96 33.71 40.45 47.19 53.93 9 12 16 18 22 25 E-500 <V4" tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths. Ordering Eiimplt: 1-bundle -500-4 E-500-3 E-500-4 E-500-5 E-500-6 E-500-7 E-500-8 *per lineal foot S 1.02 six 3' lengths six 4' lengths six 5' lengths six 6' lengths six 7' lengths six 8' lengths 18.33 24.44 30.56 36.67 42.78 48.89 8 10 12 16 19 21 r?'. ACCESSORIES End Cap-3" wide-Right Hand End Cap-3" wtde-Left Hand Valve Enclosure--4" wide--Right Hand Valve Enclosure-4" wide--Left Hand Valve Enclosure-6" wide-Right Hand Valve Enciosure-6" wide--Left Hand Inside Corner-hinged front and top-90* Inside Corner-back piece-90* Inside Corner-one-piece front and top--135*/45* Inside Corner-back piece-135*/45* Outside Comer-90* Outside Corner-13S*/45* Filler piece set-7" wide Filler piece set-14" wide Wall End Piece-3" wide Return tubing wire hangers Connecting tubing wire hangers Joining piece set-2" wide Extra support brackets with slide cradles and damper clips Tube bending tool NOTE: Finished with white prune paint. RA-ECR-03 RA-ECL-03 RA-VER-04 RA-VEL-04 RA-VER-06 RA-VEL-06 RA-ICF-90 RA-ICB-90 RA-ICF-45 RA-ICB-45 RA-OCF-90 RA-OCF-45 RA-FPS-07 RA-FPS-14 RA-WEP-03 RA-WHR-50 RA-WHS-50 RA-J PS-02 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 5 box of 10 bag of 50 bag of 50 box of 20 sets RA-SBP-20 box of 20 sets For comparative and estimating purposes only. NOTE: Add 25'. :o price when ordering in less than quantities indicated above. 8.40 8.40 11.55 11.55 17.64 17.64 10.50 3.36 10.50 3.20 12.60 14.70 8.50 6.SO 4.41 2.10 2.21 5.46 7.40 14.55 4 4 9 9 10 10 3 4 2 2 5 3 9 9 4 -- -- 5 5 HH-1 2 See sace 52 Page 42 01559 l5J STANDARD HYDRONIC HCATIN6 HEATRIM PANELS MODEL SS HEATRIM PANELS, ELEMENTS AND ACCESSORIES Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools and churches. The SS Heatrim is ideal for residential "hard to heat" areas such as bathrooms, hallways, etc. SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For t " Modal S575 and 1" Model S3-1 CO Panels) DESCRIPTION nmo7 package* per Pries MODEL SS-75 COMPLETE UNITS (Dual Pack) Box includes 2 each of front and back panel, % " element, damper, necessary support brackets and slide cradles and 1 joining piece set. Finished with off - white prime paint. Ordering Example: 1-txu SS-75-4 SS-75-2 SS-75-3 SS-75-4 SS-7S-5 SS-75-6 SS-75-7 SS-75-8 MODEL SS-100 COMPLETE UNITS (Dual Pack) Box includes 2 each of front and back panel, 1' element, damper, necessary support brackets and slide cradles and 1 joining piece set. Finished with off - white prime paint. Ordering Example: l-box SS-100-3 SS-100-2 SS-100-3 SS-10&4 SS-100-5 SS-100-6 SS-100-7 SS-100-8 'per lineal foot S 3.20 Two 2 ft. lengths Two 3 ft. length! Two 4 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths 812.80 19.20 25.60 32.00 38.40 44.80 51.20 pet lineal foot S 3.55 Two 2 ft. lengths Two 3 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths 14.20 21.30 28.40 35.50 42.60 49.70 56.80 pprai. aMpplirg veifM 14 20 26 33 39 46 52 14 20 26 33 39 46 52 MODEL SSI-75 COMPLETE UNITS (Single Pack) Box includes 1 each of front and back panel, % " element, damper, joining piece set and necessary support brackets and slide cradles. Finished with off-white prime paint. Ordering Example: I-box SSI-75-7 SSI-76-2 SSI-75-3 SSI-75-4 SSI-75-6 SSI-75-6 SSI-75-7 SSI-75-8 *per lineal foot S 3.35 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 6.70 10.05 13.40 16.75 20.10 23.45 26.80 7 11 14 18 21 25 28 MODEL SSI-100 COMPLETE UNITS (Single Pack) Box includes 1 each of front and back panel, 1' element, damper, joining piece set and necessary support brackets and slide cradles. Finished with off-white prime paint. Ordering Example: 1-box SSI <100-4 SSI-100-2 SS1-10O-3 SSI-100-4 SS1-10O-5 SSI-100-6 SSI-100-7 SSI-100-8 * V *por eomoA'ttiv# and estimjtmg purposes only. See page 52 Page 43 *per lineal foot S 3.70 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length . 7.40 11.10 14.80 iaso 22.20 25.90 29.60 7 11 14 18 21 25 28 HH-12 P*Sl 01560 HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES ^AMERICAN Si STANDARD HYDRONIC HEATING MODEL SS HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools and churches. The SS Heatrim is ideal for residential "hard to heat" areas such as bathrooms, hallways, etc. DESCRIPTION :? packaged per Trad* Trie* MODEL SS ENCLOSURES ONLY (Bulk Pock) Box includes 4 each of front and back panel, damper, necessary support brackets, connecting' tube wire hangers and 3 joining piece sets. Finished with off white prime paint. Ordering Example: 1-box $$4 MODEL SSI ENCLOSURES ONLY (Single Pack) Box includes 1 each of front and back panel, damper, joining piece set, necessary support Brackets and connecting tube wire hangers. Finished with off white prime paint. Ordering Example: 1--box ttt-4 ES-75-8 (% " tube) ELEMENTS ONLY (Buik Pack) Box includes eight 8 foot lengths of y*" element and necessary slide cradles. Ordering Example: 1-box ES-7J.I ES-100-8 (1" tube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of X" element and necessary slide cradles. Ordering ExnmpJe: 1-box ES-100-1 SS-3 SS-4 SS-5 SS-6 SS-7 SS-8 SSI-3 ssi-a SSI-5 SSI-6 SSI-7 SSI -8 ES-75-8 ES-100-8 par linaal foot S1.6S Four 3 ft. lengths Four 4 ft. lengths Four 5 ft. lengths Four 8 ft. lengths Four 7 ft. lengths Four 8 ft. lengths $19.80 26.40 33.00 39.60 46.20 52.80 `per lineal foot S1.8S 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length S 5.55 7.40 9.25 11.10 12.95 14.80 per lined foot S1.S5 Eight 8 ft. lengths $99.20 per lineel foot SI.90 Eight 8 ft. lengths $121.60 ACCESSORIES R. H. %Vt" End Covers (Short of Floor) ................................................ .. L. H. 2V4" End Covers (Short of Floor) ........... --..........................-.... .. R. H. 2%" End Covers (Extend to Floor) .............................................. . L. H. 2H" End Covers (Extend to Floor) .... -........................................ R. H. 6" End Covers (Short of Floor) ........... ......................................... . L. H. 6" End Covers (Short of Floor) ...................................................... . R. H. 6" End Covers (Extend to Floor) .................................................. _ L. H. 6" End Covers (Extend to Floor) .................................................. .. Inside Corner Covers ............................................................................... .. R. H. Valve Enclosures with hinged access door................................... .. L. H. Valve Enclosures with hinged access door................................... .. R. H. Valve Enclosures with hinged access door & knockout for mainless installation ............................................................................... .. L. H. Valve Enclosures with hinged access door & knockout for mainless installation ............................................................................... .. Wall End Pieces (Short of Floor) .......................................................... .. Wall End Pieces (Extend to Floor) ......................................................... .. Outside Corner Covers .............................................................................. .. 14" Filler Pieces ...................................................................................... .. 2* Joining Piece Sets ............................................................................... .. Support Brackets. Slide Cradles, Damper Clips .................................. .. Return Pipe Hangers ............................................................................... .. Damper Joiners ................................................................................... .. Connecting Tube Hangers ...................................................................... . SS-ECR-25S SS-ECL-25S SS-ECR-25F SS-ECL-25F SS-ECR-06S SS-ECL-06S SS-ECR-06F SS-ECL-Q6F SS-IC-90 SS-VER-06H SS-VEL-06H SS-VERK-06H SS-VELK-06H SS-WE P-255 SS-WE P-25r SS-OC-90 SS-FPS-14 SS-J PS-02 . SS-S8P-24 SS-WHR-50 SS-DJ-50 SS-WHS-DO Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Bex of 4 Box of 6 of 24 8ox of 24 Box of 50 Box of 50 Box of 50 $11.55 11.55 14.70 14.70 15.75 15.75 17.85 17.85 7.35 31.50 31.50 32.00 32.00 4.75 5.25 12.60 12:60 5.30 10.50 5.25 3.95 6.30 ppre** Mp*#f w**fM 31 42 52 63 73 84 11 14 18 22 25 29 42 48 8 8 9 9 7 7 7 7 s 13 13 13 13 4 4 5 14 4 to 1 1 `or eomporo`i<r 0"d ifimo'ifig purpOfCl only 4r- Add 25* to pne* ordering m lu than quontih*i indi<of#d obov* H-12 r See cage 52 Page 44 01561 r*l AMERICAN ca STANDARD HYORONIC HEATING RADIANTRIM BASEBOARD PANELS SEE CURRENT LITERATURE FOR APPROVED l=B=R STEAM AND HOT WATER RATINGS BASEBOARD PANELS RADIATORS RADIATOR ACCESSORIES ARCO RADIATORS width 6 tube 4, 6 tube 4 tube height. Inch** sq ft per lection ^Trado Price p*r sq ft 32 3.7 25 2.0. 3.0 19 1.6 $2.69 2.11 2.24 par lineal foot Tr*de Price-- $6.04 par s^uars foot $1.77 Model 10 Radiantrim Panel lengths <2V4 ft to 30 ft) are made up from the following sections: 1 Vk ft Left hand end section 1 ft Right hand end section 2 ft Left hand end section 2 ft Right hand end section 2 ft Center section Assembly length with legs and tappings at each end: 1Vk ft Double end section 2 ft Double end section For purpose of estimating shipping weights, use 4 Vi pounds per sq. ft. 26.15 pounds per lineal foot. Model 10 Accessories ^ Price Arco Radiators are regularly furnished with two and onehalf inch (2Vk") legs. Available on Special Order with four and one-half inch (4V4') legs, or without legs--Price on application. Arco Radiators sold only in even number of sections up to a maximum of 56 sections. For purpose of estimating shipping weights, use 4 Vi pounds per sq. ft. Ordtrisg Eustgle: 1-12 Section 25' Arco 4 Tube Vi i Vi SUNRAD RADIATORS Extension Panel with 3 Brackets Two 6 ft lengths per box........................................ $19.85 Extension Panel Retaining Bracket...................... AS Extension Panel Cover Strip ................................ A1 Assembly Clamp.................................................... 10.75 Short-Compression Corner Connection............... 3.20 Long-Compression Corner Connection ............... <.31 Retaining Block .................................................... .24 Adjustable Leg ...................................................... .34 Tie Bolt ............................................................................. 12 These itsms ara regularly furmshad as raquirsd with Mods! 10 Rt< diantrim Panels and Accessories. Pncas ara shown for rapair or re placement purposas. Packed in quantity of 10 per box (Avaiiab/e only m this minimum quantity) perboioflO Inside Corner Cover .............................................. Extended Inside Corner Cover ............................... Outside Corner Cover............................................... Valve Enclosure (all R.H. or L.H.) ......................... End Box (all R H. or L.H.) ..................................... 10" Plain Extension Piece ......................................... Extension End Piece (all R.H. or L.H.) .................... $19.71 35.73 36.49 37.10 14.76 17.23 10.60 Ordering Example 1-7 ft. Model 10 Radiantrim Panel. 1-Box of Model 10 Right Hand Valve Enclosures. Important: Incraas. lit. 5% for re cited installation--Vt" air tpoca tap and sidos, Zi" at back. Incroasa tiz. 13% for rightly racassad installationno claaranco top at sidos, Zi ' air spaca at back. type M 5 x 20 tq ft par section 2.25 Trad* Price par *q ft $2.59 Sunrad Radiators are regularly furnished with legs and twopipe inside connections. Available on special order with onepipe connections, outside tappings or without legs--Price on application. Sunrad Radiators sold in even number of sections from 4 to 30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections. Sunrad Grilles Inlet--Stamped Lattice Type.........................per section 50.33 Special No. 16 Gauge with Lecking Device................................ Price cn application For purposes of estimating shipping weights, use 8 pounds per sq ft Ordering Examplt: 1-10 Section M5 > 20 Sunred T-4 Vi x W 1-Typt M Sunrad Grille for above. EXTRA RADIANTRIM ACCESSORY BAGS Bag No. For Trad* Price 0 Double Leg Section I 2>k'-6' Panel Length 2 8Vi'-12' Panel Length 3 12W-18' Panel Length 4 18Vk'-24' Panel Length 5 24 Vi '-30' Panel Length 51.06 1.33 2.85 4.23 5.57 7.16 Sufficient quantities of these bags are regularly furnished with Radiantrim Panels. Prices shown are for extra bags as may be required. RADIATOR ACCESSORIES Trad* Pnce #*ch Arco Brackets: For 4 and 6 tub*, with Wall Plate......................................... $1.36 Arco Raciatcr Pedestals: end S'*....................................................................................... .53 i V ....................................................................................... 66 Oil.*. O' SCKCtS.................................................................................... 1.03 Nicoie*. Dlugs. Bushings, etc.: V, r\ IV, IV Plugs, Bushings ...................................... V. 1". IV Slip Nipples................................................. .36 .36 1/8" Air Vent Plugs..................................................................... .02 Radiator Rod Nuts.................................................................. i'.p -iator Rods .................................................... per section .01 ,01 Aoove items jvjiijdi* for us* only with our Radiator products. See page 52 Page 45 HH-12 01562 9 CONVECTORS r51 AMERICAN bd STANDARD HYDRONIC HEATING MULTIFIN CONVECTORS TTPE K - STOCK MODEL - FREE STANDING Expanded prices For use on two-pipe steam and hot water systems only. CGtHWf No. 4 depth (4Vi* cabinet) Mrt M. ** VtPVt IfflN. llHMMIt ti|k( Frit* 20' cabinet height No. 6 depth (6Vi' cabinet) No. 8 depth (8Vi' cabinet) No. 10 depth (10Vi* cabinet) nil M. hN Wfft ifeiMKI iM Frit* Miff Me n* wlWl (ffffNI. Tf*4* tifbff Frit* Miff M. ** # Mf*Vt tfffM. ifcep*i*f Tr*d* vti|N Frit* 20 420-20 24 424--20 10.6 13.0 IB $24.04 620-20 14.9 21 526.65 20 25.52 624-20 18.4 24 28.12 .... .... 2$ 62S-20 22 0 27 32 632-20 23.5 29 33.22 832-20 31.7 33 537.02 36 636-20 29.0 33 55.37 836-20 36.0 37 30.ee 1036-20 45.5 42 40 640-20 32.5 34 37-51 840-20 40.4 39 42.35 1040-20 51.2 48 44 644-20 36.1 37 39.71 4$ 646-20 39.6 40 41.91 648-20 49.2 46 47.10 1046-20 62.3 52 56 656-20 46.7 45 46.28 856-20 58.0 51 53.24 1056-20 73.4 58 64 664-20 53.8 52 so.se 864-20 66.9 59 55.ee 1064-20 84.5 64 24' cabinet height 545.54 49.01 55.88 82.70 60.52 20 420-24 24 424-24 28 428-24 32 36 40 44 48 56 64 12.1 20 524.97 620-24 17.2 23 525.11 14.9 22 26.68 624-24 21.2 26 30.53 17.8 25 28.44 628-24 25.4 30 632-24 29.5 636-24 33.5 640-24 37.6 33 35 38 35.70 38.12 40.85 832-24 836-24 840-24 35.6 40.5 45.5 38 40 44 539.44 42.48 45.54 1036-24 1040-24 490 55-2 45 52 644-24 41.7 648-24 45.7 656-24 53.9 664-24 62.2 42 44 50 57 43.18 45.65 50.71 55.83 848-24 858-24 864-24 55.4 65.2 75.3 50 55 63 sue 57.64 eue 1048-24 1056-24 1064-24 67.1 79.0 91.0 62 64 71 $47.69 51.48 58.85 66.17 73.54 32' cebinet height ....20 620-32 IB.7 29 625.99 24 624-32 23.1 32 31.74 --28 628-32 27.7 36 34.54 32 632-32 32.1 40 37.29 832-32 40.9 45 142.68 36 636-32 36.5 43 39.99 836-32 46.5 48 48.15 1036-32 S5.0 54 40 640-32 41.0 48 42.74 840-32 52.2 56 4907 1040-32 61.9 59 44 644-32 45.4 56 45.43 48 648-32 49.8 58 48.16 848-32 63.6 65 55.65 1048-32 75.3 69 56 656-12 33.7 37 53.63 856-32 74.9 73 5304 1056-32 86.7 76 64 664-32 |7.3 -.71 59.24 564-32 86.5 76 70.79 1064-32 102.2 84 Plugs and bushings are not regularly furnished with Multifln Convectors, but are available for separate sale at prices shown on page 45. Note: For stock model cabinet extras, see page 50. Ordering Eiimpli: l-K-636-32 Multifin. $51.37 S5.61 63.86 72.11 40.47 HH-12 ^ See cage 52 Page 46 , -- ^AMERICAN 15* STANDARD HYDRONIC MATING CONVECTORS Tip** multifin convectors Combination Price: The actual output in square feet of catalog rating-Steam (215*F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination. The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered. SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS cabinet tVP description Trad* Price Mr dll unit itr charso Stock Model j K | Floor Type-free standing............................................................ j $0.62 j $17.60 Note: Price shown for estimating purposes only. For expended prices, sec page iS. For cabinet extras, see page SO. Special Service F FG W FS FSG S FR FRG FRGB PR PRG PRGB Floor Type-free standing............................................................ Floor Type-free standing-inlet grille..................................... Wall Hung-flat top....................................................................... Free Standing-sloping top.......................................................... Free Standing-sloping top-inlet grille................................... Wall Hung-sloping top............................................................... Fully recessed-v," beveled edges............................................ Fully reeessed-i/^" beveled edges-inlet grille..................... Fully recessed-*;," beveled edges-inlet grille with bottom overlap and liner bottom.......................................... Partially recessed-114". IVi", 3", 5' flanged edges............ Partially recessed-1 14", 214", 3", 5" flanged edges-inlet grille ............................................................................................ Partially recessed-1'4", 214". 3", 5" flanged edges-inlet grille-with bottom overlap and liner bottom.................... $0.74 .74 .74 .69 .69 .69 .75 .76 .75 .77 .77 .77 $2121 24.37 2121 22.37 25.54 20.15 22.37 26.54 26.12 2549 26.94 37.14 TypW iDliffiinii Type FR {Type FRGB shown) See page 52 Note: For cabinet extras, see page 50. For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifln convectors: Multifin stock model -- 1.13 pounds. Also see page 46. Multifin cabinets (less element) -- 114 pounds. Multifln cabinets (with element): Types F, FR. PR - ltj pounds. T y oe* FF, W -- 114 pounds. 'I'l-pe C. -Impounds. Orderln' f-ranijiei: Stock Motel Multifin with an optional feature: i K-840-24 Muitifin with Metal Trim Strips. Special Service Multifin with an optional feature: : ?'.* 32-214 flange, Multifin wii-i ..nuo Damper. Page 47 HH-12 01564 CONVECTORS d AMERICAN STANDARD HYDRONIC HEATING MULTIFIN CONVECTORS - continued eonvwtr longth inch** 20 24 28 32 36 40 44 48 56 64 Elements only (when sold less cabinets) -- two-pip* stoam or hot wafer No. 4 depth No. 6 depth No. 8 depth No. 10 depth approx. unnoi.t shipping walght Trado Price unit no. approx. hipping woight Trado Prieo unit no. approx. hipping Trad. weight Pile. aetm. unit no. aMMpi(etiintc Trodo Prico 420 8 424 10 428 12 432 14 436 16 440 18 444 20 448 22 456 26 464 30 $13.86 15.02 16.17 17.36 18.67 20.30 21.67 22.94 25.52 28.22 620 13 $17.00 624 16 10.05 628 19 20JO 632 22 21.73 636 25 23JI 640 28 644 31 648 34 2SJ0 27.06 28.93 656 40 664 46 32J3 35.92 820 15 824 19 828 23 832 27 836 31 840 35 844 39 848 43 856 51 864 59 $20.06 23J1 24J6 27.06 29M 31J7 33.94 30.14 40J7 44.72 1020 1024 1028 1032 1036 1040 1044 1048 10S6 1064 21 26 31 36 41 46 51 56 66 76 *23.10 26.79 29J7 32.70 30.10 39.05 41.00 44.44 49.50 S5JS Ncic Elements only are furnished less floor supports. Muitifln elements for special one-pipe steam header application--net available. Orderiaf Example: 1-420 Multifin Element oniy-no cabinet Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee. Standard Cabinets: Standard cabinets are furnished in prime painted sheet steel-reinforced. Ho. 18 gauge front and No. 20 gauge back, ends and top, rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convecton as cur rently catalogued. MINIMUM CABINET HEIGHTS WITH DAMPERS FOR MULTIFIN AND ARCO CONVECTORS Type cabinet Multifin Are. Calf Iron F, FG W F5. FSG S FR. r RG. -'RGB PR. PRG. PHGB 20" For all depths 20" For all depths 20" For all depths 20" For ail depths 20" For all depths 20" For all depths 24" For all depths 24' For all depths 24" For all depths 24" For #4, #6, #8 depths-32" For #10 depth 20" For all deptha 20" For all depths Cabinet heights shown for types W and S are nominal heights, actual heights are 9' less. Cabinet heights for Arco Cast Iron convectors applicable to X-4 (underneath) connections only. HH-12 See page 52 Page 48 01565 , ^AMERICAN STANDARD hydronic heating CONVECTORS ARCO CONVECTORS SPECIAL SERVICE LINE wh*n sold in combination with standard cabinots COMBINATION PRICE:_____ The actual output in square feet of catalof rating-Steam <21S*F) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination. The totel price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot. plus the unit extra charge multiplied by the total number of units ordered. SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS Cabinet typ# diKrlptiM F Floor Type-free standing___ FG Floor Type-free standing- inlet grille............................. W Wall Hung-flat top................ FS Free Standing-sloping top ... FSG Free Standing-sloping topinlet grille............................. S Wall Hung-sloping top......... FR Fully recessed-?:," beveled edges...................................... FRG Fully recessed-?;," beveled edges-inlet grille .............. FRGB Fully recessed-';," beveled edges-inlet grille with bottom overlap and liner bottom.................................... Trade Met pqefrt unit extra chart* 32.43 330.17 2.43 2.43 2.43 33.83 30.17 31.74 2.43 35.23 2.43 31.74 2.43 30.17 2.43 33.80 2.43 36.84 cabinet type dMcriptlen PR Partially recessed-IVi", 2V4", 3", 5' flanged edges........... PRQ Partially recessed-IVi". 2Vi". 3*. 3' flanged edges-inlet grille ..................................... PRGB Partially recessed-IVi", 2Vi", 3*. 3' flanged edges-inlet grille--with bottom overlap and liner bottom................. w Trade PHea par unit extra so ft charge SJ2 834.85 2J2 33.39 47.43 Standard Cabinets are furnished In: Prime painted sheet steel-reinforced. No. 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors listed in cur rent literature. For illustrations of cabinets, set page i7. For cabinet extras, see page SO. Ordering Exanplt: 1-M58-20 Arco Convector Unit X-4 Hih For estimating shipping weights of Arco Convector Units use: lt pounds per square foot for cabinet portion. 3 Vi pounds per square foot for element portion. ARCO CONVECTOR -- steam or water ELEMENTS ONLY (when sold less cabinets) convector length Inchoc No. 4 3i/i" depth aopros. unit nipping ^Trade no. weight Price No. 6 5%" depth unit no. approi. chipping ^Tnde weight Price No. 8 7%' depth unit no. approx. chipping _Trade weight Price No. 10 9W depth unit no. approx. chipping wTrade weight Price 18 418 39 12232 618 57 $ 33.23 818 71 3 41.88 1018 84 8 80.43 23 423 50 29.19 623 73 42.83 823 92 54.20 1023 110 68.25 28 428 61 35.71 628 90 52.49 828 113 66.53 1028 136 80.19 33 433 72 42.30 633 106 62.34 833 134 78.71 1033 162 94.93 38 438 83 43.82 638 123 71.97 838 155 90.82 1038 188 109.89 43 443 94 5521 643 139 91.69 843 176 103.14 1043 213 124.68 48 448 105 61.71 648 146 91.25 848 197 115.47 1048 238 139.83 53 453 117 68.29 653 172 100.88 853 218 127.79 1053 264 154-57 58 458 128 74.80 658 189 110.59 858 239 140.08 1058 289 169.39 S3 463 139 81.47 663 206 120.37 863 260 182.31 1063 314 184.12 Ordtrlrtj Etimplt: 1--418 Arco Cist Iron Element only-No Cabinet X-4 Vi t Vi Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets. for sizes not listed above-price on application. See page 43 for minimum cabinet heights with dampers. "W See cage 52 Page 49 HH-12 01566 CONVECTORS d AMERICAN STANDARD HYORONIC HEATING CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS CABINET EXTRAS--STOCX MODEL MULTIFIN ONLY ITEM DESCRIPTION DAMPER Knob Operated Damper Package .................................... METAL TRIM STRIPS For recessing stock models only 20" to 36" long ...................................................................... 40' to 64" long ....................................................................... GRILLE Snap-on Inlet Grille for Stock Models Only .................... AIR VENT Air chamber with extended tube, manual vent .............. Air chamber with Dole No. 20JR auto-vent ...................... *Nota: Itam* alto availably for special tarvica Multifin. Trade Pries t 6.05 10.40 13.31 4.62 6.69 M9 SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS (Prices Indicated are for standard catalogued sizes only) ITEM DESCRIPTION Trade Price OAMPER Knob or Institutional Type ................................................................. each $ 7.21 ACCESS DOOR In standard locations 1, 2, 3, 4, 7 or 8 as shown in current literature. Hinged type with Slotted Head operator .......................................... each Hinged type with Allen Head operator ............................................. each Note: Access doors in other than standard locations 7.21 IAS Pric* on application TAMPER PROOF SCREWS Phillips or Allen Head screws (other than standard Slotted Head) per cabinet 1.16 CAM LOCKS INSULATION Allen Head Cam Locks (Allen Keys Not Furnished): Types F. FG. FS and FSG..................................................... per cabinet Types S and W (Multifin Only) ............................................ per cabinet Types FR FRG. FRGB. PR. PRO. PRGB {$ ;;;;; Not*: Additional chare* pet ord*r $5.20 1 5.94 6.94 29.18 32.78 Vi" Celotex or Fibreglas on outside of cabinet Back only................................................................................ per cabinet 12.21 Back, ends and top.................................................................................percabinet 16.07 Vi" Millboard on outside of cabinet Back only ................................................................................ per cabinet 28.60 Back, ends and top................................................................................ percabinet 40.65 SOUND DEADENING MATERIAL Approx. Vi" thick-inside front panel only............................. per cabinet 12.10 SEALING STRIP For standard length FR, FRG and FRGB cabinets only (V*" x Polyurethane) ..................................................... per cabinet 5.06 STIFFENER All fronts 46' and longer, or 32" and higher have stiffening channel spotwelded to inside front in horizontal position at no additional charge. Stiffening channel on fronts other than standard ...................................................................................... per cabinet 1.71 METAL TRIM STRIPS For recessing Types F and FG Multifin convectors only Cataloged heights and lengths up to 36~........................................ each Cataloged heights and lengths 40" to 64'...................................... each 11.66 14.36 END POCKETS Specify right or left hand side 4" end pocket with No. IB gauge vertical baffle...........per end pocket 8" end pocket with No. 18 gauge vertical baffle............. per end pocket 6.49 10.40 KNOCKOUTS Are optional-Furnished only on request Pnc* on application HEAVIER GAUGE CABINETS Trade Price per square foot of cabinet output Front Only No. 18 gauge...................................... No. 16 gauge...................................... No. 14 gauge...................................... $-- .08 .15 Linors Only $.08 .10 not *vailtbl* HH-12 yr See page 52 Page 50 01567 ^AMERICAN ksiSTANDARD HYDRONIC HEATING general INFORMATION BOILER RATINGS The net I=B=R boiler ratings represent the maximum net loads that may be connected to the boilers. The net I=B=R steam ratings are based on a piping and pickup allowance of 1.333 except where cr. appropriate piping and pickup column is shown. Steam sq: ftrratings are based on 240 Btuh per sq. ft. The net I=B=R water ratings in Mbh are based on a piping and pickup factor of 1.15. Water sq. ft ratings are based on 150 Btuh (170* water) per sq. ft. For installations having unusual piping and pickup requirements, AmericanStandard should be consulted before selecting a boiler. For forced hot water heating systems where the boiler and piping are within the area to be heated, the boiler may be selected on the basis of its gross output. Sufficient radiation must be installed for the riinrmnt; of the building to be served. In order to select the proper size boiler, calculate the heat loss of the building, then divide this Agure by 1,000 to get the heat lots expressed in Mbh. Select a steam or water boiler which has a net I=B=R Mbh rating equal to or greater than this Agure using the appropriate steam or water column. See current literature for determining the size of radiators and convectors for hot water systems. GAS FIRED BOILERS American-Standard Gas boilers are design certiAed by the American Gas Association. Ratings shown are for installation at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. OIL FIRED BOILERS The Aring rates or I=B=R burner capacities -- gallons per hour--are based on the use of oil having 140,000 Btu per gallon heat value. STOKER FIRED BOILERS The Aring rates or I=B=R burner capacities--pounds per hour--are based on the use of coal having 13,000 Btu per pound heat value. HAND FIRED BOILERS The ratings are based on the use of stove or nut size bitumi nous coal, anthracite coal or coke with 13,000 Btu per pound heat value. See table below for selecting proper size boiler when using coal with less than 13,000 Btu per pound. BUILT-IN TANKLESS WATER HEATERS for G-2 Water. G-40. G-10. A-3. FR-A-5. A-5, DPT. PFA-3. PFA-5. and VPT All tankless type built-in water heaters are rated in gallons per minute on the basis of a minimum boiler water temper ature of 200* F. The maintaining of 200* F boiler water temperature with rated flow through a tankless type builtin water heater is dependent on the output of the boiler. Increase the boiler size 12 Mbh for each bathroom in excess of two. In those areas where excessive lime exists in the water, use of built-in tankless type water heater is not recom mended except when provision is made for regularly clean ing the heater. EXTERNAL WATER HEATERS FOR AMERICAN-STANDARD STEAM BOILERS External tank or tankless type heaters can be connected to all American-Standard Steam boilers when provision is made in the supply and return piping of the heating system. When an external tank type heater is used and the domestic demand exceeds 75 gallons in a 24 hour period, increase the boiler size 120 Btuh for each gallon of storage tank capacity. When an external tankless type heater is used, increase the boiler size 12 Mbh for each bathroom in excess of two. (Note: G-10 Steam boilers can be provided with external water heater tappings for water to water heat exchangers. See G-10 optional equipment pages for price and availabil ity. A-7 boilers are regularly provided with tappings for external water to water heat exchangers.) WHERE COAL HAS LESS THAN 13,000 BTU CONTENT When selecting hand Ared boilers for burning coal of lower heating value than 13,000 Btu per pound the following cor rection factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq. ft.). heallnc value of cool correction factor 13.000...................... 1.00 12.500..................... 1.04 12.000..................... 1.08 11.500.................. 1.13 11.000 1.18 hooting valuo of cool correction foctor 10,500...................... 1.24 10,000...................... 1.30 9.500......................1.37 9,000 ....................1.44 INSTRUCTIONS FOR ORDERING GAS BOILERS: Spscify complete boiler number. Specify type of (is (whether natural or propana), Btu (heat value of gas), specific gravity. Specify elevation at point of installation if in excess of 2,000 feet and indicate barometric pressure. In addition, for Prstrure fired PfA-S pot fired and gat*oil fired units, specify 90s pressure at gas train inlet. Specify optional equipment In detail. BOILERS: REPAIR PARTS For current price, contact your American Standard distributor Refer to Boiler Repair Parts Catalog Form 9100-2 Dated 3/1/71 .............................................. OIL BURNERS: Refer to "American Standard Arcoflame Oil Burner Repair Parts Catalog" 1966 Edition & Supplements. Page 51 HH-12 01568 GENERAL TERMS d AMERICAN STANDARD HYORONIC HEATING TRADE PRICE BOOK Illustrations and descriptions of ordering Numbers listed In this price book will be found In the current American-Standard Hydropic Products Catalog and literature. Hems illustrated in product literature and not included In this price book are discontinued, me illustrations in this jyIce book although actual representations of certain products In the line, do not necessarily show sizes and details of all products in the line. This price list has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown are guides only and do not purport to represent actual prices prevailing in any particular market and are not intended to interfere with our distributors' right and responsibility to establish their own resale prices. All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein. INVOICE MINIMUM All distributors' orders. Including repairs, which aggregate less than $15.00 net will be billed at $15.00. TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH U.S. PLUMBING/HEATING TO ITS DISTRIBUTORS All sales of goods by American-Standard through U.S. Plumbing/Heating to its distributors are made subject to terms and conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions, are as follows: MICC Goods sold by the Seller will bo billed to tiie Buyer recording to the pncoo and terms contained In its current bulletins end price books. In tho case of orders for goods lor which no price M currently in effect the price will be determined by the Seller and set forth in tho Invoice Issued after shipment of tho goods. Twos. Any tax or other Government charge now or hereafter levied upon me production, sale, use or shipment of goods ordered or sold, will bo chargod to and paid for by the Buyer. endeavor to secure for Its direct Buyers the benefits of warranties sxtended by such other manufacturers lor such goods. American-Standard is proud of Its record for product quality and for fair ness In handling warranty matters; and. If an ultimate user of our products should fool our warranty tystam doeertbod above does not work fairly in his case, he should write the Office of the President Oirsctor of Consumer Affairs. U. S. Plumbing/Hosting, AmortcaivSUncard. 40 West 40th Streat. New York. N. Y. 100IS. CONTRACT WTTN BUYEft DELIVERY Transportation Alike. Delivery to the Initial carrier shell constitute delivery to the Buyer. The Seller's responsibility cesses upon delivery in good order to suen earner, and til goods are shipped at the Buyer's risk. The Buyer te urged to examine all deliveries carefully before signing transportation receipts, if goods are visibly damaged, the Buyer should msist that written confirmation of the damage be noted on the freight bill or dray ticket by the agent of the earner, if damage Is discovered after unpacking, the carrier should bo notified at once, so that inspection can bo made and the claimed damage substantiated by the carrier. Interference with Delivery. The Seller has no obligation to deliver good* against any order until it has sccspted ths order by Issuance of its acknowl edgment of order, in any event, the Seller will net be liable for tny delay or failure in the delivery or shipment of goods against an accepted order or tor any damages suffered by reason thereof, when such delay or failure Is. directly or indirectly, due to accident (In manufacture or otherwise), fire, flood, not. war. smbargo. labor stoppages. Inadequate transportation facili ties. shortage of material or supplies, deity or default on the part of its vendors, regulation by Government authority, or any like or dissimilar cause beyond its control. CONSUMES PROTECTION -- WAARANTY American-Standard products normally resell owners or consumer-users through an industry channel of distributors and plumbing and heating con tractor!. Experience hes shown that claims of defects in our products gen erally relate to abuse or to other damage which occur after our sale and are not our responsibility. Since determining proper responsibility requires local Inspection, our warranty (set forth below) extends only to our direct buyers; distributors art best equipped to obtain die facta underlying claims, to place responsibility whore it belongs and to recommend/handle repair or re placement. American-Standard warrants only to Its distributors and other direct Buyers that it will furnish by freight a replacement for. or at Its option repair, any product of its manufacture or part or portion thereof, proved to its satisfac tion to be defective in material or workmanship under normal use and service within one year after installation. There is no other warranty, express or implied. Including no implied war ranty ef marchanlability er Implied warranty for fitness for s particular purposa and American-Standard will net ba responsible for any damages whatsoever, nor for labor or transportation espenaoe relating to such re placement or such repair, nor wilt it be held responsible for warranty adjustments costing mors than ths price of the product to Its distributors and other Oirsct Buyers. ficeaptears of Orders. Orders will be accepted only by the Seller s usual acknowledgment of order containing terms and conditions applicable thereto. No torma and condition* appearing in a Buyer's order that are at variance with die Seller's terms and conditions shell be binding upon tho Seller unteee specifically agreed to by M In writing. Unless the Seller spe cifically re agrees in writing In acknowledging any order, any terms and conditions appearing m a Buyer's order contrary to those slated heroin and in such acknowledgment of order are to be deemed waived by the Buyer. Receipt by the Buyer of the acknowledgment of order without prompt obiac* tion to the terms and conditions therein and herein set forth, constitute acceptance by tho Buyer of such terms and conditions. Cancellation of Orders. After the Seller's acknowledgment of order has been issued. an order may be modified or cancelled only upon written agreement by the Seller. Orders for goods other than those of standard manufacture will not be cancelled after e commitment has boan mad* or production scheduled. Credit tor Returned Goods. Merchandise may not be returned for credit unless the Seiler hes agreed to accept it Where returns are accepted, a deduction of 10% or SIO, whichever is greeter will be made lor rehandling. All transportation costs for returned goods must be paid by the Buyer, in any event only saleable merchandise of standard manufacture may be returned for credit Credit Approvat Buyers' orders ere accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stooped m transit on accepted orders without any liability on the Seller's part, if. m Its opinion, the Buyer's ability to pay tor the merchandise on these terms and conditions is in doubt SHORTAGES OR VARIANCES No claims for variances from or shortages in orders will be considered uniats presented within 60 days after receipt of goods. PRODUCT AND PACKAGING CHANGES Factors beyond the control of the Seller and the need for continuing im. provemenl of product require the making of changes from time to time m products and their packaging. The right Is reserved to msfcs rsasonaoie changes of any kind without notice and to delivar rsvissd designs or models of good# against any order, unless on the face of the acknowledgment or order this right is specifically waived. The Seller shell have no responsibility whatever with rasped to changes made by the manufacturer in products or their packaging sold but not manufactured by the Seller. SHIPPING WEIGHTS Goods of other manufacturer* sold by American-Standard are not warranted unless accompanied by an eipress written warranty, put the Seiler will The shipping weights given harem ere approximate, for Buyers con venience only, and are not guaranteed. .AMERICAN 51 STANDARD PLUM8INC / HEATINC . 0 IOI 2003 NEW XUNSWICK. N l. 0l03 HH-12 Page 52 01569