Document QgEpzQaqw8zd4OjZEY1VB0V6L
r -p
t
trade price book for
AMERICAN-STANDARD
Hydronic Heating Equipment*
Hydronics ... the science of heating and cooling with water.
PRODUCTS
Boilers -- Cast iron
Electric Packaged Boilers
Gas: Packaged Units
Boilers
Electronic Control Systems
Oil: Packaged Units
Boiler-Burner Units
Flame Retention Boiler-
Burner Units
Boilers
Oil Pressure Fired
Gas Boiler-Burner Units Gee-Oil
Coal: Stoker Fired
Hand Fired
Oil Burners and Controls
Comfort Computer --
Zone Valve Peckegea
Hydronic Assembling Tools
Radiation:
Scsc'Ooard Panels. Heatnm
' '-'ic'itt: r-aneis: Radiantrim
. Arco, Sunrad
( << >ev - -
Multifin
Arco
Cabinet Extras
PAGE
39-40 2-6,9 7,8,10-16 17 18-19 20, 22-30, 33
29,30 21,22,28,31-33
23-28
36 37 33,35
34 38
41-44 45 45 46-48 49 50
rr -
/ - ;
J .7 i
tr
rsj. - t, ` -Kia*" . :
} -
PACKAGED BOILERS GAS fired WATER
fSIAMERICAN Si STANDARD
HYORONIC HEATING
GPMX PACKAGED GAS BOILERS
Complt^tiyfactcry assembled and pre-wired. Two-toned brown and beige jacket encloses all controls. Regularly supplied for 115 volt 60 cycle power supply with 24 volt system or self ener
gizing controls at no extra charge. (Specify controls desired) Built-in purge valve--Patent applied for. Built-in air separator, in left-hand end section. Intermittent circulator operation.
Design certified by A. G. A. for combustible floor and closet installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for propane gas -- optional for natural gas at 10% reduc
tion of rating as indicated by model number sufiix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2,000 feet.
WATER -- for natural gas -- 100% shut-off
pebtefcttoegrtd number
GPMX-3 GPMX-4 GPMX-5 GPMX-6 GPMX-7 GPMX-8
A G A. input Mb*
66 99 132 165 198 231
Aew.Ctp.wAf. Ml*
52.8 79.2 105 6 132.0 158.4 184.8
net Jraartitnxgel
Mb*
46,1 68.7 92.2 114.8 137.4 160.9
net rating wibotf*t*
307 458 615 765 916 1073
Trade Price ttawndithard gvEptnant
$329.00 359.00 410.00 469.00 526.00 583.00
*Mpaa**n*gweight
197 240 264 335 381 428
chimney lii*
inarde diem. in.
height feet
4 10 5 10 5 10 6 10 7 10 7 10
WATER -- for propane gas -- 100% shut-off
GPMX-3R
60
48 41.7
278 $329.00
197
4
10
GPMX-4B
90
72 62.6
417
359.00
240
5
10
GPMX-5R
120
96 83.5
557
410.00
284
5
10
GPMX-6R
150
120 104.3
695
459.00
335
6
10
GPMX-7R
180
144 125.2
835
520.00
381
7
10
GPMX-8R
210
168 146.1
974
583.00
428
7
10
Ordering Example*:
Packaged bailer with standard equipment: 1 OPMX-d boiler with 24 vo<t control* Nat got. 7000 6tu, .6 tg
2 Pockoged boiler with optional equipment;
I GPMX-7R boiler with 24 volt control* for conitant circulator operation, rum not, 1000 Bfu, .6 *g. kit from natural to propane
Standard Equipment
V800 series manifold gas valve includes main operator, manual shut-off, pilot filter, pressure regulator (except for propane gas) and Pilotstat.
1 %" Circulator with Piping Draft Hood
Drain valve
Wiring Harness
ASME relief valve, 30 lb. Purge Valve
Expansion Tank Auto Air Vent Automatic Fill Valve
Specify 34 Volt . . . or . - . Specify Self Energising
T822D thermostat L4080D limit control
T822D thermostat L8148G limit and circulator relay (40VA)
R8226B transformer (40VA) and circulator relay
Note: Boiler is shiDped with jacket, all controls, circulator, main burners and manifold controls and piping factory installed and wired. Purge valve, air vent and expansion tank installed. Relief valve and thermostat fastened inside boiler crate. Draft hood shipped separately.
Optional Equipment
Optional constant circulation (24 V) L4081B limit and reverse acting
circulator controls with AT20D transformer instead of 1,4080 and R8226B. Furnished at no additional charge.
Optional constant circulation (S.E.) L40S1B limit and reverse acting circulator control and TS822A thermostat instead of L8I48G and T822D thermostat. Furnished at no additional charge.
Conversion Kits: Boilers must be specified with suffix letter R. Reduced propane ratings apply.
Natural to Propane gas Pronane to Natural gas
W Trade Price 16.89 W Trade Price 16.89
Zone valve packages are available for water boilers. For details and prices, see page 34.
-'2 '.ee ;aoe 52
Page 2
f 01519
.AMERICAN SiSTANDARD
HYDRONIC HEATING
PACKAGED BOILERS GAS FIRED WATER
[| GP.V. PACKAGED GAS BOILERS
Completely factory assembled and pre-wired. Two-toned brown and beige jacket encloses all controls. Regularly supplied for 115 volt 60 cycle power supply with 24 volt system or self ener
gizing controls at no extra charge. (Specify controls desired) Built-in purge valve--Patent applied for. Built-in air separator, in left-hand end section. Intermittent circulator operation.
Design certified by A. G. A. for combustible floor and closet installations. Cast iron drilled port burners are standard equipment for natural gas. Ribbon burners are standard for Propane gas -- optional for natural gas at 10'. reduction of rating as indicated by model number suffix R. Tested and equipped for 30 lbs. water working pressure. Ratings shown are for installation at sea level and up to 2,000 feet.
WATER--for natural gas--100% shut-off
pochagrt
bail*' mwwAi
GPM-3 GPM-4 GPM-5 GPM-6 GPM-7 GPM-8
A.G.A. input
MAh
66 99 132 165 198 231
A.G.A. VtRttl
MAh
52.8 79.2 105.6 132.0 158.4 184 8
fttf lalal rating
MAh
46.1 68.7 92.2 114.6 137.4 160.9
oat rating t< water
307 458 615 765 916 1073
'qri.M* frit* with
ttanOarp
OWIpHMnt
$304.00 330.00 388.00 446.00 504.00 561.00
apprax. tapping
weight
200 240 285 335 385 430
ihitmoy mo
imi4e Aiam. in.
Height
feer
4 10 5 10 5 10 6 10 7 10 7 10
WATER--for propane gas--100% shut-off
GPM-3R GPM-4R
GPM-5R GPM-6R GPM-7R GPM-8R
60 90 120 150 180 210
48 41.7
278
72
62.6 1
417
96
83.5 |
557
120
104.3 I
695
144 125.2
835
166
146.1 I
974
$304.00 336.00 388.00 446.00 504.00 561.00
200 240 285
335 385 430
4
5 5 6 7 7
10 10 10
10 to 10
Ordering Example*: 1 Packaged boiler with itandord equipment: ) GPM-5 boiler with 24 volt control* Nat got. 1000 Btu, 6 tg. 2 Pockoged boiler with optional equipment: 1 GPM-3R boiler with $lf-n<rrgttmg con trol* lor eonitont circulator operation. Propone go*.
W See cape
Standard Equipment
V800 series manifold gas valve includes main operator, manual shut-off,
pilot filter, pressure regulator (except for Propane gas) and Pilotstat.
1'4 " Circulator with Piping Draft Hood
Drain valve
Wiring Harness
ASME relief valve, 30 lb. Purge Valve
Specify 24 Veit . . . er , . . Specify Self Energising
T822D thermostat L4080D limit control
T822D thermostat L8148G limit and circulator relay (40VA)
R8226B transformer (40VA) and circulator relay
Note: Boiler is shipped with jacket, all controls, circulator, main burners
and manifold controls and piping factory installed and wired. Relief valve and Thermostat fastened inside boiler crate. Draft :iood shipped separately.
Optional Equipment
Optional constant circulation (24 V) L4081B limit and reverse acting
circulator controls with AT20D transformer instead of L4080 and R8226B. Furnished at no additional charge.
Optional constant circulation (S.E.) L4081B limit and reverse acting circulator control and TS822A thermostat instead of L8148G and T822D thermostat. Furnished at no additional charge.
Conversion Kits: Boilers must be specified with suffix letter R. Reduced Propane ratings apply.
Natural to Propane gas Propane to Natural gas
$6.89 $6.89
Zone valve packages are available for water boilers. For details and prices, see page 34.
p age 3
01520
PACKAGED BOILERS GAS FIRED WATER
I AMERICAN L5i STANDARD
HYDRONIC HEATING
G-2 PACKAGED GAS BOILERS
Fully nnrlfoH pre-wired, and equipped with controls for forced circulation, the G-2 is a _ --quality, time-proven cast iron gas fired boiler available with and without tankless
heater for domestic water requirements. This modern deluxe jacketed boiler features the patented "Eliminaire" (cast-in air sep
arator in the left end section) and the distinctive American-Standard brown and beige jacket color combination to dress up any basement or utility room.
The boiler is tested and equipped for 30 lbs. water working pressure and is regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system. Self-ener gizing controls are avalable without extra cost.
Ratings shown are for installation at sea level and up to 2,000 feet.
WATER--for naturol ond propone gases--100% shut-off
paekagad boilar
number
A.QJL input Mbh
A.QJL output
Mbit
tanklass haatar
numbar
A IsWsH rating
net l=B=R rating
Mbh
nat rating a* ft watar
'VTrada Prlca with standard aquipmant
appraa. hipping
waight
chimnay aita inside haight diam. in. faat
Packaged boilers with factory installed tankless heater
G-24-OPT G-25-DPT
90 120
72 218 2Vz 96 222 3
62.6 33.5
417 556
G-26-DPT 150 120 222 3>/ 104.3 695
G-27-DPT 180 144 222 3 Vi 125.2 834
*494.00
552.00 607.00 657.00
Packaged boilers less heater
G-23-DP G-24-DP G-25-DP
G-26-DP G-27-DP
60 48 90 72
120 96
150 120 180 144
41.7
62.6 83.5
104.3 125.2
278 417 556
695 834
*389.00 457.00 511.00 576.00 616.00
^Gallons ol water per minute heated from 40F to 140F with 200F boiler water temperature.
416 481 551 620
333 403 472 542 603
5 10 5 10 6 10 6 10
4 10 5 10 5 10 6 10 6 10
Standard equipment
V800 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat.
l'A" Circulator with piping AS ME relief valve Draft hood (for G-23 only, shipped
in separate carton)
Pressure and temperature gauge Wirine harness
AT20D transformer (24V. less heater boilers only)
Additional standard equipment for boilers with heater
Tankless heater as listed above T822D (24V.) thermostat L8124E (24V.) or L8124B (S.E.) triple Aquastat relay
Ottering Examples:
1. Packaged boiler less heater with standard equipment.
1 G-24-0P boiler Nat. gas. 1000 Btu. .6 sg.
2. Packaged boiler with factory installed heater with optional equipment: ] G-26-DPT boiler with ribbon burners and
Nat to Propane conversion kit. Nat gas. 1000 Btu. .6 sg.
Additional standard equipment for boilers less heater
T822D (24V.) or TS822A (S.E.) thermostat L4081B (24V. and S.E.) combination hie' limit and circulator control Nat*: Left hand end section less tankles: 'cater opening
Na; Shipped with jacket, all controls (except thermostat), circulator and piping, main burners and manifold controls and piping factory installed and wired. Thermostat, manual main gas and pilot gas shut-off valves
and relief valve shipped in accessory box fastened inside boiler crate.
Optional equipment
Self-energizing controls (consist of VS820 Series gas valve, thermostat. Q313 Thermopile Generator and limit or combination control as noted above), available when specified on order................................... no charge
L8148E (24V.) or L8148G (S.E.) combination limit/relay in lieu of
L4081B furnished on G-2 DP boilers
no charge
Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit": <>*'................................................ G-23 thru G-27 -w-Trade Price 66.00
Floor shield for combustible flooring. Add suffix letter "C" to boiler number add *3.50
Nata: In areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above.
Zone valve packages are available for water boilers. For details and prices, see page 34.
Page 4
01521
f51 AMERICAN IS STANDARD
HYDRONIC HEATING
PACKAGED BOILERS GAS FIRED STEAM
G-2- PACKAGED GAS BOILERS
For steam installation on new work or modernization, the G-2 Pack aged Steam boiler is available with either Flush or Deluxe jacket in the smart and attractive brown and beige combination that labels it an American-Standard top performing cast iron boiler.
This model is factory assembled and pre-wired tor 115 volt, 60 cycle power supply with 24 volt control system. Where required, self-energizing controls are furnished without extra charge.
Ratings shown are for installations at sea level and up to 2,000 feet.
STEAM--for natural and propane gases--100% shut-off
pachagad botlar
number
A.GJl. input
Mbh
A.G.A. output
Mbh
nat IsBsft rating
Mbh
sq ft
Trada Met with standard aquipmant
fldth Jacfcat
daiwa Jaefcat
approx. shipping
waigM
chtmnay six*
inslda diam. in.
haigbt faat
G-23-SP*
60 48
36
150 8326.00
5343.00
310
G-24-SP*
90
72
54 225 395.00
412.00
376
G-25-SP*
120
96
72 300 454.00
471.00
443
G-26-SP*
150
120
90 375 510.00
527.00
518
G-27-SP* 180 144 108 450 559.00
576.00
581
4 10 5 10 5 10 6 10 6 10
* Add suffix letter "f" tor flush or "D" for deluxe ic*et
Ortering Eiimpln.1. Packages boiler with standard eouioment 1 G-26-5P0 Boiler Nat. gas. 1000 Btu. .6 sg. 2. Packaged boiler with optional eouipment: 1 C-24-SPD boiler with self-energiting con trols Nat gas, 1000 Btu, S sg.
^ See cage 52
Standard equipment
V80U Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat.
No. 67-GAR (24V. and S.E.) low PA404A (24V. and S.E.) pressure
water cut-off
limit control
Gauge glass with trimmings
AT20D transformer (except S.E.)
Draft hood (for G-23-D and G-23-F thru G-27-F, shipped in separate carton)
T822D (24V.) or TS822A (S.E.)
ASME safety valve Steam gauge Floor pan and radiation shield
thermostat
Now: Shipped with jacket, all controls (except those noted beiow), main
burners and manifold controls factory installed and wired. Thermostat,
low water cut-off, manual main and pilot gas shut-off valves (when
required), safety valve and steam limit control shipped in accessory box
fastened inside boiler crate.
Optional equipment
Self-energizing controls (consist of VS820 Series gas valve; Q313 Ther mopile Generator; and limit control as noted above) available when specified on order ........................................................................... no charge
No. 101-24V. electric water feeder is available for addition to the No. 67-GAR to provide a low water cut-off and feeder combination control
add*59.00
Natural to Propane gas conversion kits. Order boiler "with ribbon burners''
and "Natural to Propane conversion kit":
G-23 thru G-27
Trade Price 56.00
No1*: in areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above.
For Additional Optional Equipment, See page 15.
For substitution of No. 47-2 low water cut-off and feeder combina tion (shipped separate! in place of No. 67GAR specify on order and
......................................................................
......................... $44.00
Page 5
01522
HW. .
PACKAGED BOILERS GAS FIRED WATER
IAMERICAN SiSTANDARD
HYDRONIC HEATING
Q 2 PACKAGED ALL-PURPOSE GAS BOILERS
Versatile and packed with pluses. Can be used for forced circulation or gravity installations. Completely factory assembled, pre-wired and crated with Deluxe brown and beige style leading jacket. Patented "Eliminaire" ends air problems.
Tested and equipped for 30 lbs. water working pressure and regularly fur nished for 115 volt, 60 cycle power supply with 24 volt control system. Selfenergizing controls available at no added charge.
Ratings shown are for installation at sea level and up to 2,000 feet.
WATER--for natural and propane gases--100% shut-off
pecfcafed boiler
number
A.OJt. input Mbh
A.OA. output
Mbh
not ratine Mbh
net ratine
ft water
^ Trade Price with
standard equipment
leas thermostat
approk. shipping
weight
chimney size
Inside diem. in.
heifht feet
G-23-DPG
60
48
41.7
278
$285.00
G-24-DPG
90
72
62.6
417
355.00
G-25-DPG
120
96
83.5
556
417.00
G-26-DPG
150
120
104.3
695
474.00
G27-OPG
180
144
125.2
834
524.00
307 4 10 373 5 10 438 5 10 511 6 10 574 6 10
)
Orderinf Eumpiei: 1. Pictdged ill-purpose boiler with stindird equip ment. 1 G-25-DPG boiler Nit. {is, 1000 Btu, .6 S{. 2. Pickiged ill-purpose boiler with optional equip ment: 1 G 26 DPC boiler with self-energizing controls Nit {is. 1040 Btu, .65 s{.
HH-l 2
Standard equipment
V800 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat.
L4080B (24V. and S.E.) immersion limit control
ASME relief valve Pressure and temperature gauge
AT20D transformer (except S.E.) Draft hood (for G-23-DPG only
shipped in separate carton)
Non: Shipped with all controls, main burners and manifold controls factory installed and wired. Manual main gas and pilot gas shut-ofT valves (when required) and relief valve shipped in accessory box fastened inside
boiler crate.
Optional equipment
Self-energizing controls (consist of VS820 Series gas valve; Q313 Theimopile Generator; thermostat and limit control as noted above) avail able when specified on order ........................................................ no charge
Natural to Propane gas conversion kits. Order boiler with "ribbon burners"
and "Natural to Propane conversion kit":
Trade Price 86.00
No,*: In areas where manual opening feature is desired, G-2 boilers are furnished with self-energizing controls as listed above.
Thermostats for 24V. and S.E. control systems are available. For prices see page 35.
Zone valve packages are available for water boilers. For details and prices, see page 34.
01523
Page 6
AMERICAN kSi STANDARD
HYDRONIC HEATING
BOILERS--GAS FIRED WATER AND STEAM
G-2 NON-PACKAGED ALL-PURPOSE GAS BOILERS
As a water boiler, this model is available with or without tankless -oi! for don-.caiic water needs With steam trim it is a tup noicn modernization item. Two jacket styles-- Fiusn or Deluxe-this line is available in nine (9) sizes with factory assembled sections.
Featuring the patented "Eliminaire" cast-in air separator in left end section, the boiler is tested and equipped for 30 lbs. water working pressure, 15 lbs. steam and is regularly furnished for 115 volt, 60 cycle power supply with 24 volt control sys tem. Self-energizing controls are available without extra charge.
Ratings shown are for installation at sea level and up to 2,000 feet.
WATER--Natural and Propane Gases--(Available with factory Installed Tankless heater, see options, pages IS A 16) --100% shut-off.
toller number
A.QJL. input Mbh
A.6JL
output Mbh
net
ratine Mbh
net rating tp ft water
Trade Pile# with standard equipment
lea thermostat
flush Jacket
deluta Jacket
approx. weight'
chimney size
Inside diam. in.
height feet
G-23-*W
G-24-*W(T) G-25-*W(T)
G-26-*W(T) G-27-W(T) G-28-*W(T)
G-29-*W(D G-210-*W(T) G-211-*W(T)
60 90 120
150 180 210
240 270 300
48 41.7 278 $257.00
72
62.6
417
325.00
96 83.5 556 388.00
120 104.3 695 445.00 144 125.2 834 494.00 168 146.1 974 551.00
192
167.0
1113
216
187.8
1252
240 208.7 1391
807.00 657.00
713.00
$273.00 342.00 405.00
482.00 511.00 588.00
824.00 874.00 730.00
295 353 426
500 566 630
699 790 863
4 5 5
6 6 7
7 7 7
10 10 10
10 10 10
10 10 10
Substitute letter "f'` for flush or **0M for delude jacket. Suffix `T" denotes forced circulation Dollar equipped with factory installed tankless heater (see page 16 for addad charge).
STEAM--Natural and Propane Gases--100% shut-off.
boiler number
A.G.A. input Mbh
A.Q.A. output
Mbh
net l=8sft
rating
Mbh soft
Trade Price with standard equipment
less thsrmestat
flush Jacket
deluxe Jacket
1st
chimney slat
Inside diam. in.
height feet
G-23-*S G-24'S
60 48 36 90 72 54
G-25*S 120 96 72
G-26-*S
G-27-*S G-28-*S
150 120
90
180 144 108
210 168 126
G-29-S
240 192 144
G-210-*S 270 216 162 G-211-*S 300 240 180
'Substitute letter "F" for flush or "O for deluxe jecket.
150 225 300
375 450 525
600 675 750
$303.00 371.00 434.00
491.00 540.00 597.00
853.00 703.00 759.00
$319.00 388.00 451.00
508.00 557.00 614.00
670.00 720.00 776.00
310 368 442
517 583 648
718 809 883
Standard Equipment
4 5 5
6 6 7
7 7 7
10 10 10
10 10 10
10 10 10
V800 Series manifold gas valve including main operator, manual shut-off valve, pilot filter, pressure regulator (except Propane gas) and Pilotstat.
Ordering Cumpltt: 1. Non-oackiged kit-durooM water boiler with standard equipment and flush jacket: 1 G-27-FW boiler Nal gas, 1000 Bin. 6 sg. 2. Non-cackiged all-purpose water boiler with optional equipment and deluie jacket: 1 G-210-DWT boiler with (1) No. 232 tankless heater installed Nat gas. 1000 Btu. .6 sg
For Other Optional Equipment. See page 15.
AT20D Transformer (except S.E.) Drain valve Draft hood (for G-23-D and all flush jack
eted boilers shipped in separate carton)
Additional standard equipment
Water boilers ASME relief valve Pressure and temperature gauge L4080 (24V. and S.E.) Aquastat
limit control
Net.: Zone valve packages are available
for water boilers. For details and prices, see page 34.
Steam boilers ASME safety valve Steam gauge
PA404A (24V. and S.E.) pressure limit control
No:67-GAR (24V. and S.E.) low water cut-off
Gauge glass with trimmings Floor pan and radiation shield
Optional Equipment
Electronic Control Panel Systems--see page 17 for prices,
Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit":
G-23 thru G-27 G-28 thru G-211
Trade PriceS&.OO Trade Price$8.10
See page 52
Page 7
HH-1?
01524
BOILERS--GAS FIRED WATER AND STEAM
rz\ AMERICAN
SJ STANDARD
HTDRONIC HEATING
G-40 GAS BOILERS
This fine boiler is ideal for installation in larger residences,
small apartments, and commercial buildings. Has deluxe jacket with built-in draft hood. Note that tankless heaters :c liable Xui both steam and water. Features ''Lumi
naire" cSSt ITI the left end section. Regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system. Self-energizing controls optional. Tested and equipped for 50 lbs. water working pressure with 80 lbs. water pressure optional at extra
cost. Tested ratings shown are for installation at sea level and up to 2,000 ft.
WATER -- For Natural and Propane Gases -- 100% Shut-Off. For Built-In Water Heaters, see page 16.
nvmber
G-40J-W
G-406-W G-407-W
G-4010*W G-4011-W G-4012-W G-401J-W G-4014.W
A.G.A. int Mbit
150 225 300 375 450 525 600 675 750 825 900 975
A.O.A. vtpwf
Mbh
120 180 240 300 360 420 480 540 800 660 720 780
fWt IwBml miny
Mbh
104.3 156.5 208.7 260.9 313.0 365 8 417 4
469.6 521.6 574 0 626.2 676.4
net rating
n ft. wnt*f
69$ 1043 1391 1739 2066 2434 2782 3130 3479 3827 4175 4523
Trade Prtra with
sfnndnrd
Imi HiirnMat
< 428.00 44.00 000.00 781.00 903.00 998.00
1111.00 1227.00 1344.00 1403.00 1870.00 1004.00
M'** thippwtf weight
827
1182
1686 1656 2026 2195 2364 2533 2702
diimiwy >is
inside disn. in.
8 6 6
hsifht (mi
15
STEAM - For Natural and Propane Gases - 100% Shut-Off. For Built-In Water Heaters, see page 16.
bsilst number
G-404-S G*40S*S G-406-S
G-40I-S
G*4011-S G-4012-S G *4013-6 G-4014-8
A G.A. innut Mbh
150 225 300 375 450 525 600 675 750 625 900 975
A.G.A. eutpwt
Mbh
120 160 240 300 360 420 480 540 600 660 720 760
net IssBs R rating
Mbh
90.0 135.0 180.0 225 1 270 1 315.1 360.1 405 1 450.0 495.2 $40.0 585 1
e ft.
375 563 750 936 1125 1313 1500 1688 1875 2063 2250 2438
Trade Pries with
etnnderd ysipniM
1 474.00 560.00 706.00 27.00 940.00
1041.00 1160.00 1273.00 1300.00 1509.00 1835.00 1740.00
npgran. thinning weight
858 1027 1105 1370 1544 1713 1600 2050 2219 2360 2557 2726
Ainner tilt
inside diem. in.
8 8 8 10
height feet
15
10 10 12 12 12 12 15
Ordering tramples:
1. Water boiler Kith standard equipment: 1 G-406-W boiler Nat. (as. 1000 Btu. .6 S|.
2. Steam boiler with optional equipment: 1 C-409-ST 1 No. 226 tankless heater with controls Nat. (as. 1000 Btu. .6 s(.
Standard equipment
V800A Combination Gas Valve; (i-403 and G-404 for Natural Gas VBOOB Combination Gas Valve; G-403 thru G-407 for Propane Gas G-50AAG Combination Gas Valve: G405 and G-406 for Natural Gas V-88A Diaphragm Gas Valve; G-407 thru G-4014 for Natural Gas
G-408 thru G-4014 for Propane Gas
Gas pressure regulator (except propane gas) Manual main gas shut-olf valve Manual pilot gas shut-off valve where diaphragm gas valve is standard.
AT20D Transformer (except S.E.) L62GB (24V.) or CS591A (S.E.) combination pilot switch and valve with
auxiliary pilot valves (100% shut-off)
Drain valve Water heater opening cover plates
Additional standard equipment
Water
ASME relief valve Pressure and temperature gauge L4006A (24V. and S.E.) immersion limit control Zone valve packages are available for water boilers. For details and prices, see page 34.
Steam
ASME safety valve
Steam gauge PA404A (24V. and S.E.) pressure him*, control Gauge glass with trimmings No. F7-GAR (24V. and S.E.) low
water cut-off
Optional equipment (See page*. 15, 16 and 17)
HH-12
Page B
01525
JAMERICAN ISi STANDARD
HYDRONIC HEATING
PACKAGED BOILER GAS FIRED WATER
GWP PACKAGED GAS BOILER
(Single Boiler Installation)
The GWP bciU; package offers a ready-to-install heating plant for large residences, small apartment and commercial buildings. Designed for forced circulation only, the GWP includes factory mounted and wired controls. Burners are installed and deluxe jacket is factory mounted. Relief valve, temperature-pressure gauge and draft hood are shipped separately. The patented "Eliminaire" is also included.
Boiler is tested and equipped for 50 lbs. working pressure and regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system. Self-energizing controls are available at no additional cost.
Ratings shown are for installations at sea level and up to 2000 ft.
WATER--100% shut-off--Natural and Propane Gas
iMotir* GWP-5 GWP-6 GWP-7
A.G.A. **vt Mte+i 264 330 396
A.G.A. MMi 211 2
264 0
316 8
** l*ll
Mfcfc 183.5 229.6 275.7
thlwwwy tin
Imid* 4i. m.
twffM
7 15
8 IS
8 15
***W wlfM 613 716 823
Trwte Mn vitft
WipIWRl lii ihinMitO $456.00
551.00
657.00
Standard equipment
Combination automatic gas valve
Gas pressure regulator (except propane)
Manual main gas shut-off valve
Manual pilot gas shut-off valve AT-20D transformer (except S.E.) Pilot Valve & Switch Drain Valve
ASME Relief Valve
Pressure-Temperature Gauge
Deluxe Jacket
L4080D Immersion Limit Control
Draft Hood Drilled Port Burners are standard
for natural gas. Ribbon Burners are standard for
propane gas and optional for nat ural gas.
Optional equipment
Self Energizing controls
No Price Add
Zone Valve Packages are available (for details and prices see page 34)
* Add suffix "R" to model number if ribbon burners are desired.
Example: GWP-5R
Optional constant circulation (24 volt) L4081B limit and reverse actinp circulator controls instead of L4080 limit control. Added Trade Price g 10.90
Electronic Control Panel Systems, see page 17 for prices. For applica tion and details, contact American Standard.
P'' See page 52
Page 9
HH-12
01526
MOOULAR GAS FIRED WATER BOILER
f51 AMERICAN LSSTANDARD
HYDRONIC HEATING
GWM GAS MODULAR BOILER HOOK-UP
(Modular. Boiler Installations)
The GWM Modular Boiler Hook-up is a combination or multiple of five, six or seven section GWM boiler modules. Each module has factory assembled sections with burners, gas manifold, and automatic gas valve mounted. Deluxe jacket, controls and draft hood are shipped separately. The patented "Eliminaire" is a standard feature.
Factory fabricated water manifolds are available as listed under optional equipment.
GWM Modular Boilers are furnished for 1X5 volt, 60 cycle power supply with 24 volt control system. (Self-energizing controls are not available). Boilers are tested and equipped for 50 PSIG working pressure. Indicated ratings are for installation at sea level and up to 2000 ft. elevation.
GWM BOILER MODULES - Natural and Propane Gas: 100% Shut-Off.
m*4vl nwmbffe*
GWM-5
AG.A. input 264
A.G.A. uMtpMwt 211.2
n#t Islsl raMtMinf 183.5
GWM-6
330
264.0
229.6
GWM-7
396
316.8
275.7
fcippiftf Wifhn
lb. 629 735
846
Tro4with tlawdard qVlpfMflt
!$ rhnnitar $443.00
538.00 644.00
Standard equipment
Combination automatic Gas Valve
Gas pressure regulator (except propane)
Manual Main Gas shut-off valve
Manual pilot gas shut-off valve Transformer Relay R8227B Pilot valve and switch Drain Valve ASME Relief Valve(s) as required
Pressure-Temperature Gauge as required
Deluxe Jacket L4080D Immersion Limit Control
Draft Hood Drilled Port Burners are standard
for natural gas.
Ribbon burners are standard for propane gas and optional for nat ural gas.
Optional equipment
1. Factory fabricated Water Manifold for Primary/Secondary circulation. Includes interconnecting supply piping (Boiler to manifold). Inter connecting return piping and circulator not included. .......................................................... Trade Price add per module 143.00
2. Factory fabricated Water Manifold for Parallel Boiler Hook-up. In cludes interconnecting supply and return piping (boiler to manifold). ......................................................... Trade Price add per module $87.00
3. Electronic Control Panel Systems, see page 17. For application and details, contact American Standard.
Add suffix "R" to module boiler number if ribbon burners are desired. Example -- GWM-6R
HH-12 See race i
Page 10
01527
AMERICAN L5J STANDARD
HYDRONIC HEATING
MODULAR GAS FIRED WATER BOILER
GWM GAS MODULAR BOILER HOOK-UP
(Modular Boiler Installations)
The following boiler units in 66,000 BTU input increments are achieved with module boiler combinations:
MODULAR BOILER HOOK-UPS -- Natural and Propane Gas - 100% Shut-Off.
volt nvmbtf
GWM-528 GWM-594 GWM-660
GWM-726 GWM-792 GWM-858
GWM-924 GWM-990 GWM-10S6
GWM-1122 GWM-1188 GWM-12S4
GWM-1320 GWM-1386 GWM-1452
GWM-1518 GWM-1S84 GWM-1650
GWM-1716 GWM-1782 GWM-1848
GWM-1914 GWM-1980 GWM-2046
GWM-2112 GWM-2178 GWM-2244
GWM-2310 GWM-2376 GWM-2442
GWM-2508 GWM-2574 GWM-2640
GWM-2706 GWM-2772 GWM-2838
GWM-2904 GWM-2970 GWM-303E
GWM-3102 GWM-3168 and upward
modular competition
S ItTt.
2 1 -
_ --
2
--
__
--
1 __
--
_
--
-
_
_
_
_
-
_
_
__
_
--
__
-
_
4 lOct.
_
1 2
1
--
1
2 3 2
1
_
3
4 3 2
1
_
5
4 3 2
1
_
5
4 3 2
1
S
4 3 2
1
_
5
4 3 2
1
7 MCI.
--
-
2 -
_
--
1
2 3 -
_
1 2
3 4 -
1 2 3
4 5 1
2 3 4
5 6 2
3 4 s
6 7 3
4
s
6
7 8
gratt input Mbh
S28 594 660
726 792 856
924 990 1056
1122 1188 1254
1320 1386 1452
1518 1584 1650
1716 1782 1848
1914 1980 2046
2112 2178 2244
2310 2376 2442
2508 2574 2640
2706 2772 2838
2904 2970 3036
3102 3168
groti output Mbh
422.4 475.2 528.0
580.8 633.6 686.4
739.2 792.0 844.8
897.6 950.4 1003.2
1056.0 1108.8 1161.6
1214.4 1267.2 1320.0
1372.8 1425.6 1478.4
1531.2 1584.0 1636.0
1689.6 1742.4 1795.2
1848.0 1900.8 1953.6
2006.4 2059.2 2112.0
2164.8 2217.6 2270.4
2323.2 2376.0 242B.B
2481.6 2534.4
not output Mbh
367.0 413.9 459.1
504.3 551.3 596.5
643.5 688.7 733.9
780.9 826.1 873.0
918.3 963.5 1010.4
1055.7 1102.6 1147.8
1193.0 1240.0 1285.2
1332.2 1376.4 1422.6
1467,6 1516.5 1561.7
1607.0 1652.2 1697.4
1746.1 1791.3 1836.5
1881.7 1927.0 1975.7
2020.9 2066.1 2111.3
2156.5 2205.2
approx. thippiny weight
1258 1364 1470
1581 1692 1993
2099 2205 2316
2427 2538 2834
2940 3051 3162
3273 3384 3675
3786 3897 4008
4119 4230 4521
4632 4743 4654
4965 5076 5367
5478 5589 5700
5811 5922 6213
6324 6435 6546
6657 6768
Modular Operating Control Package Options
1. Four stage ir.-.mersiofi tyjje operating control, (one required for up to
4 modules i
J1?............... Trade price add per control $74.00
2. Immersion tyn^'iperating controls with individual outdoor resets. ................... Trade price add per module 150.00
3. Eight stage boiler sequencing control panel system with outdoor reset, (one required for up to 8 modules! Trade price add per control$286.00
Trod* Price with Bfondard opuipmont
loit rhomtotiat
$ 870.00 965.00
1060.00
1166.00 1272.00 1392.00
1487.00 1582.00 1688.00
1794.00 1900.00 2009.00
2104.00 2210.00 2316.00
2422.00 2528.00 2642.00
2748.00 2854.00 2960.00
3066.00 3172.00 3270.00 3376.00 3482.00 3588.00
3694.00 3800.00 3898.00
4004.00 4110.00 4216.00
4322.00 4428.00 4526.00
4632.00 4738.00 4844.00 4950.00 5056.00
01528
^ See cace 52
Page 11
HH-12
non-packaged
gas fired
WATER
P51AMERICAN ksaSTANDARD
HTDRONIC HEATING
GW NON-PACKAGED GAS WATER
(Single or Modular Boiler Installation*)
The GW Boiler is a non-packaged boiler available in three sizes designed for forced circulatton-only. Factory assembled sections are standard with jackets, burners and manifolds shipped separately. Included for field installation are a relief valve, tempera ture-pressure gauge, and draft hood. The patented "Eliminaire" is also included.
Installed individually or in modular groups, the GW boiler is ideal for renovation work as well as new construction.
Each boiler is tested and equipped for 50 PSIG working pressure and regularly fur nished for 115 volt, 60 cycle power supply with 24 volt controls. Self-energizing controls are available at no additional cost.
Ratings shown are for installations at sea level and up to 2000 ft. elevation.
INDIVIDUAL BOILERS - WATER - 100% shut-off - Natural and Propane Gas
wuwBit*
Gw-a GW-9 GW-10
AG-A ingui Mbit
462 528 594
A.C.A. wtpvt
MM
369.4 422.4 475.2
IWf l*UI
MM
321.7 367.0 413.9
chinmor fiu
lm*M dia. in.
9 10 to
fati
15 15 15
wvifM
938 1052 1177
Trod* with
1*91 ihftiMtwl
(710.00 769.00 S27.00
MODULAR BOILERS - WATER - 100% shut-off - Natural and Propane Gas
vn>t
ftvmWr
m*dwlor <*n**(*t*
< Mil.
f !<(-
io Ir.
yroit
tnnvl
MM
r' MM
n*f 9tpy
MM
GW-924 GW-990 GW-10S6
GW-1122 GW-1188 GW-1386
GW-1452 GW-1518 GW-1584
GW-1650 GW-1716 GW-1782
GW-1B48 GW-1914 GW-1980
GW-2046
200
924
1 10
990
0 2 0 1056
739 792 845
0 1 1 1122 879
0 0 2 1188
950
3
0
0
1386
1108
2
1
0
1452
1162
1
20
1518
1214
0 3 0 1584 1267
02
1
1650
1320
0
1
2
1716
1373
00
3
1782
1426
4 0 0 1848 1478
3
1
0
1914
1531
2 2 0 1980 1584
1
3
0
2046
1637
644 689 734
781 826 964
1010
1056 1103
1148 1193 1240
1285 1332 1376
1423
OBfffOI. Jiippiftf rvtyhN
1876 1990 2104
2229 2354 2814
2928 3042 3156
3281 3406 3531
3752 3866 3980
4094
Trod* Rrtc* wjNi standard qui^manf
ln rh--maofot
(1420.00 1479.00 1538.00
1596.00 1654.00 2130.00
2189.00 2248.00 2307.00
2365.00 2423.00 2481.00
2840.00 2899.00 2950.00
3017.00
Standard equipment
Combination automatic gas valve
Gas Dressure regulator (except propane)
Manual gas shut-off valve Manual pilot gas shut-off valve
AT-20D Transformer (except SE) Pilot Valve and Switch Drain Valve
ASME Relief Valve
Pressure-Temperature Gauge
L-4080D Immersion Limit Control
Deluxe Jacket
Draft Hood
Drilled Port Burners are standard for natural gas.
Ribbon Burners are standard for propane gas and optional at no price add for natural gas.
Optional equipment
Self-energizing controls ........................................................... no price add Electronic Control Panel System, see page 17. For application and de tails. contact American Standard.
Modular Operating Control Package Options 1. Four stage immersion type operating control (one required for up to
4 modules) .......................................Trade Price add per control 174.00
2. Immersion type operating controls with individual outdoor resets (one required for each module)............ Trade Price add per module$50.003
3. Eight stec; boiler sequencing control package with outdoor reset (one required for up to 8 modules) ...... Trade Price add per control (286.00
Add suffix "R" to model number if ribbon burners are desired.
-IH-12 ^ See cage 52
Page 12
01529
I AMERICAN kSi STANDARD
HYORONIC HEATING
BOILERS-GAS FIRED WATER
G-10 GAS BOILERS
A compact, high capacity boiler for commercial and industrial application. Features single com
bustion chamber to simplify wiring and controls. Built-in heaters available for storage tank or tankless application. Tested and equipped for SO lbs. water working pressure with 80 lbs. water
working pressure optional at extra cost.
Integral draft hood lm-s.ted st rear of boiler with optional top outlet (except G-1010) available at
no extra cnarge.
"
WATER -- Noturol Gas -- 100% Shut-Off. For Built-In Water Heaters, see page 16.
bolfar numbtr
A.OJL Input Mbh
A.QA. output Mbh
A ot IkIbR piping and rating Mbh Pick-up factor a
*"Trada Priea
nat rating ag. ft watar
with standard aguipmant
tharmaatat
appr>shipping walght
cfclmnay sisa
insMa dtam. In.
hta
Q-10S-W G-106-W G-107-W
G-108-W G-109-W G-1010-W
G-1011-W G-1012-W G-1013-W
6-1014-W 6-1015-W G-101S-W
G-1017-W G-10H-W G-1019-W
G-1020-W G-1021-W G-1022-W
G-1023-W G-1024-W G-102S-W
G-102S-W G-1027-W G-102S-W
G-102B-W G-1030-W G-1031-W
G-1032-W G-1033-W
800 1000 1200
1400 1600 1800
2000 2200 2400
2600 2800 3000
3200 3400 3600
3800 4000 4200
4400 4600 4800
5000 5200 5400
5600 5800 6000
6200 6400
640 800 960
1120 1280 1440
1600 1760 1920
2080 2240 2400
2560 2720 2880
3040 3200 3360
3520 3680 3840
4000 4160 4320
4480 4640 4800
4960 5120
556.5 695.7 834.8
973.9 1113.0 1252.2
1391.3 1530.4 1669.6
1808.7 1947.8 2087.0
2226.1 2365.2 2504.3
2643.5 2782.6 2921.7
3060.9 3200.0 3339.1
3478.3 3617.4 3756.5
3895.7 4034.8 4173.9
4313.0 4452.2
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15
3710 4638 5565
6493 7420 8348
9275 10203 11131
12058 12985 13913
14841 15768 16695
17623 18551 19478
20406 21333 22261
23189 24116 25043
25971 26899 27826
28753 29080
91338.00 1627.00 1915.00
2223.00 2484.00 2748.00
3027.00 3379.00 3796.00
4102.00 4359.00 4628.00
4909.00 5204.00 5510.00
5767.00 6073A0 6342.00
6648.00 6929.00 7187.00
7493.00 7787.00 7996.00
8203.00 8521.00 8779.00
9035.00 9305.00
2706 3153 3827
4107 4584 5077
5568 8148 6659
7179 7752 8248
8744 9253 9765
10301 10778 11341
11851 12360 12891
13384 13876 14374
14878 15368 15891
16406 16936
14 14 14
16 16 18
18 20 20
22 22 22
22 24 24
24 26 26
26 26 28
28 28 28
30 30 30
30 30
20 20 20
20 20 20
20 20 20
20 20 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30
Tht r\*t isBsR ratings shown art batad on tha factors shown in tha piping and pickup column. Amoncan Standard should ba consuttad bafora salacting a botiar for installations having unusual piping and pickup raquirsmants.
Standard equipment
V88A or B50D gas valve(s)
Drain valve
Gas pressure regulator (except
Draft hood
Propane gas)
L62GB combination pilotstat and
Manual main gas shut-off valve
H17BA1 pilot valves
Manual pilot gas shut-off valve
Pressure and temperature gauge
AT20D Transformer
L4006A immersion limit control
Ribbon type main burners
Optional equipment: See pages IS. 16 and 17.
ASME relief valve
Onltfing Examples:
]. Watar toilir. 1 C-J013-W boilsr Hit. (a*. 1000 Btu, 6 if.
page 52
G-10 GAS BOILERS -- WATER for Propane Gas
Propane Gas Ratings are determined by reducing the Natural ratings above by 10%. Example: G-105-W A.G.A. input 800 less 10%=720 Mbh Input for Propane Gas Detailed Propane Gas ratings are shown in current Technical Literature. Trade Prices, Chimney Sizes and shipping weights remain the same as shown above.
Page 13
HH-12
01530
BOILERS-GAS FIRED STEAM
(AMERICAN L5iSTANDARD
HYDRONIC HEATING
G-10 GAS BOILERS --
This steam boiler is ideal for new work or modernisation. Features a deluxe jacket which
may be assembled to the boiler after piping has been installed. Integral draft hood locat ed at rear of boiler with optional top outlet (except G1010) available at no extra charge.
Tins boiler is regularly furnished for 115 volt, 60 cycle power supply with 24 volt con trol system. Ratings shown are lor installation at sea level and uo to 2.1)00 ft.
STEAM - For NatorafGas - 100% Shut-Off. For Built-In Water Heoters (G-1055 thru G-1014S only) See pogo 16.
beilir numbtr
A.GJL Input
Mbh
A.GJL output
Mbh
a nt 1 w B = ft rating
Mbh
aq. ft.
lwB~* piping and
pick-up factor A
Trade Price with standard
equipment IMS
tharmoatat
approx. ahipping weight
chimn ay else
inaida diam. in.
hL ft
G-10S-S G-106-S G-107-S
800 1000 1200
640
480.1
2000
1.333
$1382.00
2706
14
20
800
600.1
2501
1.333
1673.00
3153
14
20
960
720.2
3001
1.333
1961.00
3627
14
20
G-108-S
1400
1120
840.2
3501
1.333
2269.00
4107
16
20
G-109-S
1600
1280
962.4
4010
1.330
2530.00
4584
16
20
G-1010-S
1800
1440
1095.1
4563
1.315
2795.00
5077
18
20
G-1011-S
2000
1600
1227.9
5116
1.303
3074.00
5568
18
20
G-1012-S
2200
1760
1361.2
5672
1.293
3426.00
6146
20
20
G-1013-S
2400
1920
1489.5
6206
1.289
3843.00
6659
20
20
G-1014-S G-1015-S G-1016-S
2600 2800 3000
2080 2240 2400
1614.9 1739.1 1863.4
6729 7246 7764
1.288 1.288 1.288
4149.00 4406.00 4675.00
7179 7752 8246
22 22 22
20 20 30
G-1017-S G-1018-S G-1019-S
3200 3400 3600
2560 2720 2880
1987.6 2111.8 2236.0
8282 8799 9317
1.288 1.288 1.288
4957.00 5250.00 5557.00
8744 9253 9765
22 24 24
30 30 30
G-1020-S G-1021-S G-1022-S
3800 4000 4200
3040 3200 3360
2360.2 2484.5 2608.7
9834 10352 10870
1.288 1.288 1.288
5814.00 6119.00 6389.00
10301 10778 11341
24 26 26
30 30 30
G-1023-S
4400
3520
2732.9
11387
1.288
6695.00
11851
26
30
G-1024-S
4600
3680
2857.1
11905
1.288
6976.00
12360
26
30
G-1025-S
4800
3840
2981.4
12422
1.288
7233.00
12891
28
30
G-1026-S
5000
4000
3105.6
12940
1.288
7540.00
13384
28
30
G-1027-S
5200
4160
3229.8
13458
1.288
7633.00
13876
28
30
G-1028-S
5400
4320
3354.0
13975
1.288
6042.00
14374
28
30
G-1029-S
5600
4480
3478.3
14493
1.288
6250.00
14878
30
30
G-1030-S
5800
4640
3602.5
15010
1.288
8568.00
15368
30
30
G-1031-S
6000
4800
3726.7
15528
1.288
8826.00
15891
30
30
G-1032-S
6200
4960
3850.9
16046
1.288
9082.00
16406
30
30
G-1033-S
6400
5120
3975.2
16563
1.288
9351.00
16936
30
30
a The r>et l = B=R rating* shown are based on the factors shown m the piping and pickup column. American Standard should be consulted before selecting a boiler tor installations having unusual piping and pickup requirements.
Standard equipment
V88A or B50D gas valve(s) Gas pressure regulator
(except propane gas) Manual main gas shut-off valve Manual pilot gas shut-off valve AT20D Transformer ASMfc safety valve Steam gauge Ribbon type mam burners
Ordering Dimples:
Slum froiitr with standard aquipmant I GI015-S boiler Nat |as. 1000 8tu. .65 if
Drain valve Draft hood L62GB combination pilotstat and
H17BA1 pilot valves PA404A pressure limit control Gauge glass with trimmings No. 67AR Low Water cut-off
Optional equipment
(See pages 15, 16 and 17)
G-10 GAS BOILERS -- STEAM for Propane Gas
Propane Gas Ratings are determined by reducing the Natural Gas ratings above by 10%. Example G-105-S A.G.A. Input 800 leas 10%=720 Mbh Input for Propane Gas Detailed Propane Gas ratings are shown in current G-10 Technical Literature. Trade Prices, Chimney Sizes and shipping weights remain the same as shown above.
hH-12 See cage :'
Page 14
01531
I AMERICAN k5i STANDARD
HYDRONIC HEATING
MISCELLANEOUS OPTIONS GAS BOILERS
MISCELLANEOUS OPTIONS - NON-PACKAGED GAS BOILERS
G-2, G-40 AND G-10 BOILERS: Thermostats are available at Trade Prices shown on page 35.
Side Outlet ASME Steam Safety Valve may be substituted at no additional charge if specified on order to meet local code requirements.
"IS" Equipment: boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. L4006A immer sion operating control for use m storage tank is required and will be furnished when specified on order at extra Trade Price as shown on page 35. This control operates gas valves on boiler electrically as required. Shipping weights of gas boilers for hot water supply are same as shown for regular gas boilers.
No. 47-2 boiler water feeder and cut-off combination is available instead of the 67-AR regularly furnished with G-2, G-40 and G-105 thru G-108 steam boilers at additional Trade Price of ............................................................. $44.00
Low water cut-offs for water boilers: No. 63 cut-off for water
working pressures of 50 lbs., or less, available when speci
fied at additional Trade Price of
$45.25
No. 150 cut-off for water working pressures in excess of 50
lbs. available when specified at additional Trade Price of
.................................................................................................
$68.00
G-2 AND G-40 BOILERS:
Self-energizing control: All size G-2 and G-40 for propane gas. All G-2 and G-40 thru G-4010 for natural gas. Equip ment includes: S.E. gas valve as required, Q313A Thermo pile Generator and a L4006 S.E. limit control (water boilers less heater) or an L8124B Triple Aquastat Relay (water boilers with heater) or a PA404A Pressuretroi (steam boilers less heater). For steam boilers with heater L4006A S.E. immersion operating control will be furnished in addi tion to the Pressuretroi. Furnished at no additional charge when specified on order. Special thermostat required, for Trade Price, see page 35.
No. 101-24V electric water feeder can be added to the No.
67-GAR low water cut-off regularly furnished with
steam boilers to provide low water cut-off and feeder combi
nation at additional Trade Price of
$59.00
Zone circulator control for water boiler with tankless heater and combination immersion control-relay: use one T822D thermostat and one R845A relay for second and/or third zone. For Trade Prices, see page 35.
Water flow regulators sized for tankless heater involved will
be furnished with heater when specified on order to meet
local Utility requirement at Trade Pnce additional charge
per heater of
$3.50
G-40 AND G-10 BOILERS:
No. 51-2 boiler water feeder and cut-off available instead of No. 67-AR regularly furnished with G-109 thru G-1033 steam boilers at additional Trade Price of .............. $67.00
Try-cocks and tappings: if desired for steam boiler to meet
local code specify on order and add to Trade Price of steam
boiler
$4.50
Boilers tested for 80 lbs. water working pressure: available
when specified i crder. Add per section to Trade Pnce of
water boiler
$8.50 per section
G-2 BOILERS:
"DW" (Direct Water) equipment: In addition to water boiler standard equipment, page 7, includes pressure gauge, 80 lb. ASME relief valve, L4006A Aquastat for storage tank, tank thermometer, name and rating plate for 80 lbs. water work ing pressure. Specify boiler with "DW" equipment and add $17.49 to Trade Price of All-Purpose Water Boiler, page 7.
Floor shield for combustible flooring. Add suffix letter "C" to
boiler number and add to Trade Price of boiler
$3.50
G-40 BOILERS:
Boilers with Tankless Heaters: water (for forced circulation) and steam boilers can be furnished with tankless heaters. Heaters are limited to boiler sizes as shown in ratings table on next page. Specify heater and add suffix "T" to boiler number.
Factory assembled sections: G-403 through G-4014 can be shipped with sections factory assembled when specified on order. Add $11.66 per section to Trade Price of boiler.
G-10 BOILERS:
Pilot filters for G-10 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes.
G-10 Steam Boiler external water heater tappings in cover
plates: maximum size 154*. Specify number of cover plates
with tapping. Added Trade Price per tapping
$4.50
G-10 Right End Section Steam Trim Tappings for pressure gauge and water column fittings or for auxiliary controls furnished as standard equipment at no additional charge.
Modulating gas valve: the G-10 boiler can be specified with
the V4055A/5055B gas valve for Hi-Lo-off operation. This valve permits adjustment of the Lo-fire operation down to a minimum of 20% of the boiler input. Operation of the
valve should be controlled by a SPST operating control. If desired, specify on order and add to the Trade Price of the boiler with regular equipment the following Trade Prices.
G-105 thru 1018 ...................................................... $171.00
G-1019 thru 1033
$217.00
Top outlet draft hood (natural gas only); available (ex cept G1010) at no extra charge when specified on order. See current literature for chimney recommendations.
Factory assembled sections: Available thru G-101J. Specify
on order. Allow 3 week lead time. Added Trade Price per
section
$22.00
' See cage 52
Page 15
01532
HH-T2
TANKLESS HEATERS-GAS FIRED WATER AND STEAM
IAMERICAN ei STANDARD
HYDRONIC HEATING
G-2 TANKLESS HEATERS
G-2 NON-PACKAGED ALL-PURPOSE BOILER: Factory installed tankless heaters: When hoilpr* Id thr-,1 11
section) are to be used -for-forced circulation. See table below for I=W=H ratings and applicable boiler size. Specify heater, add suffix "T" to boiler number and "factory installed." Add Trade Price shown.
G-2 PACKAGED AND NON-PACKAGED ALL-PURPOSE BOILERS:
Tankless heaters: When boilersj4 thru 11 section) are to be Uecvl fur forced circulation i=w'=ti tameless heaters can be installed in opening used for gravity tapping flange cover. See table for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below.
Ratings ____________________________________________ Trade Prices
bollor nurnbtr
A.G.A. Input 0tu/hr.
haatar 218
IsWkH Rating
haatar 222
haatar 226
232
haatar
218
factory fnatallod
$48.00
Old separata
$25.00
G-24
90,000
2'/z
G-25
120,000
3
G-26
150.000
3'/.
_
222
52.00
30.00
_
226
<5.00
42.00
_
232
73.00
51.00
G-27 G-28 G-29
180.000 210,000 240.000
3 Vi 4 3 Vi 4'/.
_ `L8124E for 24 Volt or L8124B for SE, Triple Aquastat Relay furnished with
3 Vi 4 Vi 4Vi heater (packed in trim box).
G-210
270.000
314 4 Vi 4% Water flow regulator. Specify on order. Added
G-211
300.000
3 Vi 4 Vi 5
Trade Price............................................. $3.50
G-40 TANKLESS HEATERS -- STEAM OR FORCED WATER BOILERS
Ratings (Gallons per minute*)
Trade Prices
iohar
MUTER 211 HUTU 222 HUTU 228 HUTU 232 HUTU 445 HUTU 460 Staam Watar Stall* W|t*f Staam Watar Staam Watar Staam Watar Staam Watar
6-403
3
6-404
3 Vi 4
4 *'/t
6-405
3 Vi
6-406
3 Vi 4
4 *'/$ 5 Vi 6 4 5'/. 6
---- ---- -- -- -- ---- --
6-407 6-408
3Vi 4 3'A
4 <Vi 4 4 Vi
fi 6'A
7'A -- --
6 6`A 7 Vi 8 8 Vi 9
--
--
6-409 6-4010 6-4011 6-4012 6-4013 6-4014
3 Vi 3 Vi 3'A 3 >4 3'A 3 Vi
4 4 4 4 4
4 6 6 Vi 7>4 8 8% 9
4 Vi
6 6 Vi 7`A
8
9
4 < Vi 6 SVz 7>A 8 'A 9
4 *Vi 6 6 Vi 7Vi 8 8 Vi 9
4 'A S 6`A 7'A a A 9
4 4 *<i 6 6 Vi 7Vi IVi 9
--
--
11 12 13 13
'Gallons ot watar par mmuta aaa trom *Q*F ro 140*F with 200*F bonar watar tamparaiura.
--
-- --
--
--
-- 12 13 1`A 15'A
G-10 BOILERS --TANKLESS OR TANK TYPE HEATER
No. 1023 heater is available in any quantity. Specify number
required. Trade Price each
$35.50
HUTU NO.
HUTU WITH CONTROLS
Watar
Stumf)
HUTU ONLY Watar ar Staam
218
$44.00 $40.00
S2S.00
222
48.00
49.00
30.00
226
01.00
97.00
42.00
232
70.00
64.00
91.00
445
4.00
90.00
99.00
460
00.00
09.00
71.00
Tankless heaters with controls for water boilers: L8124E combination immersion control-relay
packed in trim box in place of standard limit
control.
Tankless heaters with controls for steam boilers: L4006A immersion operating control
packed in trim box in addition to PA404A
pressure limit control.
Water flow regulator. Specify on order. Added Trade Price ..................................... $3.50
(') Additional L4006A operating control re quired for steam boiler-heater combina tions shown shaded. Add to above heater
w/control Trade Price
$15.00
The ratings table on this page shows the ratings attained if more than one heater is connected in parallel.
Copper pipe manifolds, factory assembled for multiple heater parallel hookup, shipped in boxes of 2 manifold assemblies per box, when specified with heaters, are avail able at the following charges:
Manifold Assembly Two Heater Three Heater Four Heater
Tride Price
$ 7.75
$11.75
$14.75
All G-10 water boilers and sizes G-105S thru G-1014S steam boilers can be provided with sections for insertion of heaters at no extra charge. When desired add suffix letter T to boiler number and specify the number of sections with heater openings. Cover plates to close unused water heater openings
will be furnished only if specified on order at Trade Price
each
$4.75
When specified, the G-10 water boiler with heater can be provided with the combination L8124E in place of the L4006A limit control at the added Trade Price of $19.50
When No. 1023 heaters are used in steam boilers, the L4006A operating control will be required for installation in a heater tapping. See page 35 for Trade Price.
When the No. 1023 heaters are used in a storage type domestic hot water system, the L4006A operating control will be required for insertion in a storage tank, see page 35 for the Trade Price.
NO. 1023 HEATER RATINGS TANKLESS APPLICATION
boifor numtar
no. of tanklots
haatora
Intarmlttowt draw
haatar rating gpm @ 100 rtaa
praitur* drop
(with manifold*)
PSI
<2-105 - G-1033 G-105 - G-1033 G-106 * G-1033 G-108 G-1033
1 2 3 4
4 V* 7/, 10
12*4
19 14 12 11
NOTE: Haatar* for Staam 8oilor avtifabla 5 thro 14 tactions anty
STORAGE TANK APPLICATION
haifor niimbtr
mimbar
af haatar*
G-105 G-1033 G-105 G-1033 G-106 G-1033 G-108 G-1033
G-1011 G-1033 G-1013 G-1033 G-1014 - G-1033 G-1016 G-1033
<2*1018 G-1033 G-1020 0-1033 G-1022 G-1033 G-1024 . G-1033
1 2 3 4
5 6 7 8
9 10 11 12
continuum draw
190* hM ipm
4 7 10 13
16 19 22 25
28 31 34 37
apaStr
100* rim
IP*
240 420 600 780
960 1.140 1.320 1.500
1.680 1.860 2.060 2.220
bailor output raaulrad
mbh
200 350 500 650
800 950 1.100 1.250
1.400 1.550 1.700 1.850
NOTE. Haatar* tor Staam Boilar* availablt 5 thro 14 mctiant only.
startga tank stia tali.
500 500 500 1.000
1.000 1.000 1.500 1.500
1.500 2.000 2.000 2.000
HH-12 See rage 52
Page 16
01533
L^SIANUARD HYDRONIC HEATING
F.M./F.I.A. SPECIAL GAS CONTROLS ELECTRONIC CONTROLS
NOTE: FIA always requires Gas Train (1) plus Electronic Control Panel System (2) FM requires Gas Train (1) and may require Electronic Control Panel System (2)
(1) G-40 AND G-10 CONTROL OPTIONS
G-40 AND G-10 BOILERS:
F.M. or F.I.A. equipment F.I.A. require* special f* train PLUS F.I.A. electronic panel
Special gas manifold control equipment that meets F.M. or F.I.A. minimum requirements are available at the Trade Price listed. For actual F.I.A. installations and before boiler installation, signed approval by F.I.A. inspector of both electronic controls and gas manifold control equipment being used should be obtained. Submittal data for F.M. or F.I.A. equipment is available from American-Standard. Electronic control systems are available as described and at the Trade Prices listed below.
Note: A low water cut-olT for water boilers (50 lb. or 80 lb. water working pressure) will be furnished as required and charged for at the prices shown for No. 63 or No. 150 on page 15.
F.M. A F.IA. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY)
BOILER NUMBER
ADD TO BOILER TRADE PRICE
r.u.c)
7.I.A.O
G-403 thru G-4014 G-10S thru G-108 G-107 G-108 thru G-1011 G-1012 thru G-1017 G-1018 G-1019 thru G-1030 G-1031 thru G-1033
$ 89.00 77.00 80.00 80.00
129.00 174.00 180.00 231.00
$493.00 465.00
501.00 506.00 690.00 753.00 602.00 932.00
F.M. gee control equipment includes two manual nui*oft valves, a test vont valve and one AH2/V710 Hydromotor Valve
F.I.A. gas control equipment includes two manual ahut-otf valves. Hi and LO pressure switches, two AH2/V710 Hydromotor Valves and a vent valve.
(2) GAS BOILER ELECTRONIC CONTROL PANEL SYSTEMS
(FOR 115 VOIT, 40 CYCLE 1 PHASE POWER ONLY)
Panel System EPG-M: Provides manual ignition, 100%
safety shut-off with electronic supervision of pilots 1 to 3. Main burners and pilots are turned off on pilot failure.
Continuous flame pilot operation. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Baso
valves and thermocouples and Q-179B electronic flame rod and pilot; RA890F protectorelay installed on panel; 3 ft. flame rod wire per pilot.
Panel System EPG-ES: Provides electronic supervision of each pilot (1 to 3) and interrupted continuous burning pilot electronically turned off and electrically relighted on every cycle to achieve positive component check of relays and pilot system. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C
pilot solenoid valves; RA890F protectorelay installed in panels with 2-4 seconds response timing and alarm con tacts; minimum of 3 ft. of flame rod wire and 3 ft. of
ignition cable per pilot.
Panel System EPG-E: Provides electronic supervision of
each pilot (1 to 3) and intermittent electric ignition of all
pilots. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired
and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panel with 2-4
seconds response timing and alarm contacts; minimum of
3 ft. of flame rod wire and 3 ft. of ignition cable per pilot.
Panel System EPG-M(FIA): Specifically designed to meet FIA requirements. Provides constant burning manually lighted electronically supervised pilots (1 to 3). 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; alarm bell, alarm silencing switch; purge timer, all factory assembled in master panel; RA 890F protectorelay installed in panel; Baso valves and thermocouples and Q-179B electronic flame rod pilot; 3 ft. flame rod wire per pilot.
ADDITIONAL CHARGES-Z.Trade Price
Specify on order type of system desired, as described above, and add charge for boiler size involved to Trade Price of boiler with regular equipment.
PANEL SYSTEMS EPG-M
Boiler no.
system no.
G-2, GW. G-40
EPG-M1
G-105 thru G-1012
EPG-M1
G-1013 thru G-1023
EPG-M2
G-1024 thru G-1033
EPG-M3
added charge <i) 5206.00 205.00 396.00 594.00
PANEL SYSTEMS EPG-E
boiler no.
system no.
G-2, GW, G-40
EPG-E1
G-105 thru G-1012
EPG-E1
G-1013 thru G-1023
EPG-E2
G-1024 thru G-1033
EPG-E3
added charge (1) $225.00 228.00 420.00 530.00
PANEL SYSTEMS EPG-ES
boiler no.
system no.
added charge (1)
G-2. GW, G-40
EPG-ES1
$272.00
G-105 thru G-1012
EPG-ES1
272.00
G-1013 thru G-1023
EPG-ES2
464.00
G-1024 thru G-1033
EPG-ES3
675.00
PANEL SYSTEMS EPG-M(FIA)
boiler no.
system no.
added ehargo
G-2. GW, G-40
EPG-MI(FIA)
$376.00
G-105 thru G-1012
EPG-MI(FIA)
376.00
G-1013 thru G-1023
EPG-M2(FIA)
575.00
G-1024 thru G-1033
EPG-M3(FIA)
782.00
Flame Rod Wire: Trade Price per foot Ignition Cable: Trade Price per foot
$0.40 Q ec
(') Note: If purge timer 11 desired. specify order and add $$2.00 Trade Price
*Tr#d# pncn *00111 to eauioment whin thiQPOd with POiler. For field conversion*, pries on application
W See page 52
Page 17
HH-12
01534
PACKAGED BOILER-BURNER UNITS
WATM
filAMERICAN kS STANDARD
HYORONIC HEATING
DP (Ti-as/105 PACKAGED BOILER-BURNER UNITS
The ideal boiler-burner unit combining compact dry base design with the efficient DH-F flame retention burner. Dual bring rate allows for job flexibility. Two nozzles supplied with each boiler. Furnished with controls for forced circulation. The DP(T)-95/105 boiler is tested and equipped for 30 lbs. water working pressure. 115/GO/I electrical characteristics are standard.
WATER
piekigid umt
number
groee IseSsR output
mbh
isBsft bumor capacity
gpe
tonkloM heater number
tankitae hoator capacity gpm
---------------- 1
not ISpBft
rating mbit
not rating ag- ft. water
Trade Price WHfl
tender* equipment
approi. hipping
weight
chimney ate
Packaged unita with factory installed tankless heater with R-8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control.
DPT-95 95 .90 218 3 82.6 550 $540.00 496 8x8x15 .90-80'S DPT-105 105 1.00 218 3 91.3 606 540.00 496 8x8x15 1.00-80'S
Packaged units less tankless heater with L40S0B Aquastat limit control, and separate R8184G light sensing primary control.
DP-95
95 .90 --
DP-105 105 1.00 --
-- 82.6 550 $500.00 -- 91.3 608 SOO.OO
Gallon* of water per minute from 40*? to 140*? with 200*? botier water temperature. NOTE Water volume 9-6 gallons.
481 481
8x8x15 8x6x15
.90-80'S 1.00-80'S
Standard equipment:
Model DH-F Arroflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat. Light weight insulating fire brick com bustion chamber. Nozzles--Two (high firing and low fir ing rate) each boiler. Draft regulator. ASME relief valve. Pressure and temperature gauge. 1VL" circulator and piping Wiring harness. Drain valve.
Note: Units are shipped with flush jacket and with all electrical controls (except thermostat), circulator and piping, fac tory installed and wired. DH-r Arcoflame oil burner shipped separately. Draft reg ulator, relief valve and thermostat shipped inside boiler crate.
Two-stage fuel unit is available for DH-F oil burner. Specify on order and add to Trade Price ......................................... $6.50
HH-12 See sage 52
Page IB
01535
d AMERICAN STANDARD
HYDRONIC HEATING
PACKAGED BOILER-BURNER UNITS
WATER
VP(T) PACKAGED BOILER-BURNER UNITS
Hivh performance. compact.. wt base boiler matched with highly efficient flame re tention burner ideal -for renovation and replacement jobs as well as for quality new construction. DH-F burner, quiet 1725 RPM, flame retention type designed and proven for reliability and performance. Notales for two firing rates provided with each of three section arrangements (3, 4, 5). Dual firing rate allows for job flexibility and possible expansion while always maximising domestic hot water capacity.
Furnished with controls for forced circulation. The VP(T) boiler is tested and equipped for 30 lbs. water working pressure. 115/60/1 electrical characteristics are standard.
ATEB
peckeged unit
number
gross IsBsB output
men
IsIsR
burner capacity
0P*
tankless heater number
tankleaa heater capacity gpm
net IsBsR
rating
mbh
Ml rating q. ft water
Trade
Price with
standard equipment
ppm shipping
weight
chimney site
water volume
(!.)
noala toes
iekaged units with factory Installed tankleee heater
With R8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control.
VPT-115 VPT-130
115 130
1.05 130 3V4 100.0 667 5580.00 575 1.15 130 314 113.0 753 5(0.00 575
8x8x15 8x8x15
15.6 ' 15.6
1.00-60* semi solid
and 1.10-60* semi solid
VPT-170 VPT-190 VPT-230 VPT-250
170 190 230 250
1.50 131 4% 147.8 985 700.00 685
1.70 131
4% 165.2 1102
700.00 685
2.05 132 6
200.0 1333
790.00 795
2.25 132 6
217.4 1449
790.00 795
8x8x15 8x8x15 8x8x15 8x12x15
20.0 20.0 24.4 24.4
1.50-80* solid and
1.65-80* solid
2.00-60* semi solid and
2.25-60* semi solid
ekaged units less tankless hestar
VP-115 VP-130 VP-170 VP-190 VP-230 VP-250
115 1.05 -- 130 1.15 -- 170 1.50 -- 190 1.70 -- 230 2.05 -- 250 2.25 --
With R8182F Aquastat-relay combination, limit and circulator control, light sensing primary control, one heater opening cover plate.
-- 100.0 667 5540.00 560 -- 113.0 753 540.00 560 -- 147.8 985 660.00 670 -- 165.2 1102 660.00 670 -- 200.0 1333 729.00 780 -- 217.4 1449 729.00 780
8x8x15 8x8x15 8x8x15 8x8x15 8x8x15 8x12x15
15.6 15.6 20.0 20.0 24.4 24.4
1.00-60* semi solid and
1.10-60* semi solid
1.50-80* solid
1.65-60* solid
2.00-60' semi solid
2.25-60* semi solid
tiiona of water per mmute from 40aF to 1*Q*F with 2DQ*F boiler watte temperature.
Sfe 5age 52
Standard equipment:
Model DH-F Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat. Scientifically designed pre-cast refrac tory combustion target wall. Nozzles--Two (high firing rate-lo firing rate) each boiler. Draft regulator. ASME relief valve. Pressure and temperature gauge. 114" circulator with piping. Wiring harness. Drain valve.
Not#: Units are shipped with flush jacket and with all electrical controls (except thermostat), circulator and piping, fac tory installed and wired. Arcoflame oil burner shipped separately. Draft regu lator, relief valve and thermostat shipped inside boiler crate.
Zone valve packages are available for water boilers. For details ar.d prices, see page 34.
Ordering Eiomple:
1. Pockoged unit with healer with
equipment*
l VFT-I15 boiler-burner unit
2. Packaged unit leu heoter with equipment: 1 VP-115 boiier*a.jfiief *
(fondord standard
Page 19
HH-12
01536
BOILER-BURNER UNITS WATU AND STUM
LSII
AMERICAN STANDARD
HYDRONIC HEATING
A-3 NON-PACKAGED ALL-PURPOSE BOILER-BURNER UNITS
If you prefer your oil-fired boilers unpeckaged for convenience and flexibility, choose the A-3 Non-Paekaged Boiler-Burner unit in one of five sizes for water or steam, with
or without tankless heater. This boiler offers you A-3 versatility. It can be used on 45^
forced circulation or gravity systems or steam. New improved ratines are achieved
witn present DH-5 oil burner having 1,725 rpm motor.
The flush jacket installs easily and provides free access to all controls and burner for quick adjustment and servicing.
The factory assembled sections are tested and equipped for 30 lbs. water working pres sure. Motor and controls are regularly furnished for 115 volt, 60 cycle power supply.
WATER
befler*
burner unit
number
ima Isftsft
output Mbh
Isftsft burner capacity
ph
Unfciecs heater number
A IsWsH
rating
net Isftsft rating
Mbh*
net rating aft watar
'Trade Price with
atandorri equipment
jsssu weight
chimney tee
Forced circulation units with factory installed tankless heater With R8182D Aquastat-relay combination, high
limit, low limit and circulator <
A-33M-WBT 108 1.00 222 4
A-34M-WBT 148
1.35 230 4
A-35M-WBT 188 1.70 328 4>/e
A-36M-WBT 228 2.20 335 5 Vi
A-37M-WBT 268 2.50 335 5 VI
93.9 128.7
163.5 198.3 233.0
626
856 1090 1322
1553
$509.00
07.00 715.00 816.00 908.00
666
756 878 1016 1148
8x8x 15
8x8x15 8x8x 15 8x8x 15 8x 12 x 15
Forced circulation units less heater With R8182F Aquastat combination, limit and circulator control, light sensing primary control.
A-33M-WB
A-34M-WB
A-35M-WB A-36M-WB A-37M-WB
108
148 188 228 268
1.00
1.35
1.70 2.20 2.50
93.9 128.7 163.5 198.3 233.0
626 858 1090 1322 1553
$474.00
571.00
886.00 763.00 859.00
658 740
875 1005 1138
8x8x 15
8x8x 15 8 x 8 x 15 8x8x 15 8x 12 x 15
Gravity units less heater: With L4O80A Aquastat limit control, and separate R8184G light sensing primary contra
A-33M-WBG A-34M-WBG A-35M-WBG A-36M-WBG A-37M-WBG
STEAM
boiler* burner
unit number
108 1.00
148 1.35 188 1.70
228 2.20 268 2.50
grots Isftsft
output Mbh
IsftsR burner capacity
gph
tankJeea heater
number
IsWsH rating
93.9 128.7 163.5 198.3 233.0
net Isftsft rating
Mbh
626
858 1090 1322 1553
$469.00
566.00 661.00
758.00 854.00
nat Isftsft
aft steam
^FTrade Price
with
etandard equipment
657
739 874 1004 1137
8x8x15
8x8x 15
8x8x15 8x8x 15
8x12x15
approx. hipping
weight
chimney ixe
Steam units with factory installed tankless heater With PA404A Pressuretrol, L4006A Aquastat operating
control, and separate R8184G light sensing primary control.
A-33M-SBT 108
1.00
222 3 Vi
81.0 338 3509.00
A-34M-SBT 148 1.35 230 3 Vi
111.0
463
6073)0
A-3SM-SBT 188 1.70 328 4 VS
141.0
588
715.00
A-36M-SBT 228
2.20
335 4 Vs
171.0
713
816.00
A-37M-SBT 268
2.50
335 5 Vi
201.0
838
908.00
667 752 879
1017
1149
8x8 x 15 8x8x IS 8x8x 15
8x8x 15 8x 12 x 15
Steam units less heater With PA404A Pressuretrol, and separate R8184G light sensing primary control.
A-33M-SB A-34M-SB A-35M-SB
A-36M-SB A-37M-SB
108 148
188 228 268
1.00
1.35
1.70 2.20 2.50
81.0 338 $469.00
111.0
463
5663)0
141.0
686
661.00
171.0
713
758.00
201.0
838
854.00
658 740
875 1005 1138
8x8x 15
8x8x 15 8x8x 15 8x8x 15 8x 12 x 15
Nozzle sizes, gen, 70 soils, furnlsned witn tn sbove units: A-33, 1.00: A-34, 1.3S; A-35. 1.75: A.36. 2.25; A-37, 2.50.
AGailons of watar par minute hasted from 40*F to 140*F with 200*F bo.Ur watar tamparatura.
Standard equipment:
Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. T822D thermostat.
Scientifically designed pre-cast refrac tory combustion chamber. Nozzle. Draft regulator. Drain valve. Units WITH water heater: 1 cover plate with Vs- control tapping. Units LESS heater: 2 cover plates for heat er openings.
Zone valve packages are available for water boilers. For details and prices, see page 34.
Ordering Examples:
1. All-Purpose boiler-burner unit wilh standard equipment: For forced circulation, wilh heater: 1 A-37M.WBT boiler-burner unit For groviry circulation: 1 A-33M.WBG boiler-burnar unit
2 AII-Fu.-pose boiler-burner unit with optional -uo- '7..'3n:: .''I, n rd circulation, loss hoalor: 1 >.-35M-WB boilor-burnor unit wilh twostage fuel unit.
Water ASME relief valve. Pressure and temperature gauge.
Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings.
Optional equipment: See page 22.
Page 20
01537
d AMERICAN STANDARD
HYDRONIC HEATING
OIL FIRED BOILERS WATEt AMD STEAM
A-3 ALL-PURPOSE OIL FIRED BOILERS
For the boiler that spells quality and dependability, look no further than the A-3 with factory-assembled cast iron sec tion assembly that is tested and equipped for 30 lbs. water working pr**urc. The flush jacket slips on easily. This _ boiler provides outstanding performance.
See page 52
WATER
pm IsBsIt
output lAbh
IsBsIt bumor
capacity
*ph
tank!cos heatar numbor
l=W=H rating
not
IsBsIt rating Mbh
Boiler with factory installed tankless heater--forced circulation
not rating
Wfl wator
'Trodo Plica
approx.
SB1
A-33M-WT A-34M-WT A-35M-WT A-36M-WT A-37M-WT
108 148 188 228 268
1.00 222 4 1.35 230 4
1.70 328 4/ 2.20 335 5>/4 2.SO 335 S*A
Boiler lesa heeter--gravity or forci>d circuittion
93.9 128.7 163.8 198.3 233.0
626 868 1090 1322 1553
$3344)0 432.00
840.00 841,00 737.00
613 698 825 962 1093
8x8x15 8x8x15 8x8x15 8x8x15 8x12x15
A-33M-W A-34M-W A-35M-W A-3SM-W A-37M-W
108 1.00 148 1.35 188 1.70 228 2.20 268 2.50
93.9 128.7 163.8 198.3 233.0
626 858 1090 1322 1S53
$307.00 4044)0 499.00 890.00 802.00
605 687 822 951 1083
8x8x15 8x8x15 8 x 8 x 15 8 x 8 x 15 8x 12 x 15
STEAM
Dollar numbar
pm
IsBsIt output
Ubh
IsBsIt bumor
capacity BPb
tanklooa hootor numbor
A JsWsH rating
Boiler with factory instilled tankless heater
A-33M-ST
108
1.00 222 3'/s
A-34M-ST 148 1.35 230 3`/2
A-35M-3T 188 1.70 328 4/
A-36M-ST 228 2.20 335 4>/
A-37M-ST 268 2.50 335 5>/
Boiler lesa heater
not IsBsft rating
Mbh
81.0 111.0 141.0 171.0 201.0
not IsBsIt
OB ft stoam
^Trada Price
338 $334.00 463 4324)0 588 540.00 713 641.00 838 737.00
approx.
SUSP
chimney slxo
614 699 826 963 1094
8x8x 15 8x8x 15 8x8x15 8 x 8 x 15 8x12x15
A-33M-S A-34M-S A-35M-S A-36M-S A-37M-S
108 1.00 148 1.35 188 1.70 228 2.20 268 2.50
81.0 338 $307.00
111.0
463
404.00
141.0
588
409.00
171.0
713
5964)0
201.0
838
6924W
606 688 823 952 1084
A Gallon* of water par mmuta haattd from 40*F to 140*F with 200*F bailor wator tamparatura.
8x8x15 8x8x15 8x8x15 8 x 8 x 15 8 x 12 x 15
Only i*B*R approved oil burnou, such as tha OH-5 burner, may ba usad with A3 oil flrad Dollars. Othar i*BR approvad burnars ara available, Consult your American Standard Olstrlct Office for details.
Standord equipment: Scientifically designed pre-cast refrac tory combustion chamber. Drain valve.
Water ASMS relief valve. Pressure and temperature gauge.
Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings. Optional Equipment, See page 22.
a-35 -- A-37 Sent Anemones available ;cs:c` trade price cnar9e of $17.00
Meta: Boilers with factory Installed tewiri-..
beater are ihipped with one water heater opening cover plate with y.' control tap ping. Boilers less factory installed heater are shipped with an additional water heater opening cover plate (blank).
Zone valve packages are available for water boilers. For details and prices, see page 34.
Ordering Exempt..:
1. Water boiler loti heater with tfandard equip. merth
1 A-34M.W boiler 2. Steam boiler with heoter with standard equip*
merit! 1 A-36M-ST boiler 3. Water boiler with heater with optional equip*
ment: I A-35M.WT boiler with jacket exten.ion
Page 21
HH-12
BOILER-BURNER UNITS Oil FIRED BOILERS WATU AND STEAM
d AMERICAN STANDARD
HYDRONIC HEATING
OPTIONAL EQUIPMENT VP(T) PACKAGED BOILER
AND A-3
FOR A-3 BOILER-BURNER UNITS AND OIL FIRED BOILERS
Jacket extension: Jacket extension provides 15H' enclosure
in front for concealment of oil burner and controls. Approx
imate shipping weight 35 lbs. Specify on order. Added Trade
Price ........................................................................
$34.00
McDonnell & Miller No. 67AR low water fuel cut-off for quick hook up installation is available for A-3 steam boilers at added Trade Price of................................... $33.00
Controls and control sets are shown on page 35.
The No. 5Z Control Set can be used for circulator zoning
with A-3 boiler-burner units with tankless heater. 1 No. 5Z
set is required for each zone in addition to the first zone
which is controlled by the No. 5 Control Set or equivalent.
Added Trade Price
$27.75
Non-packaged A-35 thru A-37 split section assemblies are available. Added Trade Price ..................................... $17.00
FOR VP(T) PACKAGED BOILERS
Two-stage fuel unit is available for DH-F oil burner at added Trade Price ...............................................................$630
Order R8182E Aquastat-ielay combination instead of R8182F (less tankless only) control to provide room thermostat control of circulator. Added Trade Price.. $5.75
FOR A-3 ALL-PURPOSE
BOILER-BURNER UNITS
Two-stage fuel unit is available for DH-5 oil burner at added Trade Price charge of.......................................................... $630
For substitution of No. 4 control set consisting of T822D thermostat, L4081B Aquastat limit and circulator control, plus R8184G light sensing primary control, instead of R8182F combination control, for non-packaged A-3 boilerburner units for forced circulation LESS heater. Added Trade Price .................................................................... $1335
For substitution of No. 5 control set consisting of T822D thermostat, L8124C Aquastat, limit, reverse and operating control, circulator relay, plus R8184E light sensing primary control, instead of R818ZD combination control, for nonpackaged A-3 boiler-burner units for forced circulation WITH tankless heater. Added Trade Price................ $535
Order R8182D Aquastat-relay combination instead of R8182F control to permit use of tankless heater with A-3 non-packaged boiler-burner units furnished less water heater. Added Trade Price ........................................... $1030
Order R8182E Aquastat-relay combination instead of R8182F control to provide room thermostat control of circulator. Added Trade Price .....................................$5.75
|=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR A-3
Heaters tested with boilers.
Built-in tankless heaters can be ordered (or separate shipment with units or boilers specified less heater as follows:
unit no.
tsBsft bumar capacity
a*
haattr no.
A IsWsH ratine
watar
otaam
^FTrada Net
A-33 A-34 A-35 A-36 A-37
1.00 1.35 1.70 2.20 2.50
222 230328 335 335
4 4 4/ 5V4 5%
3>/2 $30.00 3>/j 31.00 4>/ 44.00 4/ 48.00 5>/4 46.00
A Gallons of watar por mmuta haatad from 40*F to 140*F with 200*F boilar wator tamparatura.
HH-12 See sace 52
Page 22
01539
HYORONIC HEATING
PRESSURE FIRE0
BOILER-BURNER UNITS WATM AND STEAM
PFA-3 PRESSURE FIRED BOILER-BURNER UNITS
The PFA-3 Pressure Fired Boiler is forced-draft with flame retention burner using No. 2 oil for over 80% efficiency. Attractive two-toned brown and beige jacket with optional matching acoustically treated jacket extension. Wet base construction eliminates need for separate base. Perfect seal between boiler sections is achieved with durable sealant. Factory assembled sections are tested and equipped fur SO lbs. water working pressure. Motors ur.d conti uis regularly furnished for 115 volt, 60 cycle power supply.
WATER
bailee home*
e*ft
Smet
Imtmt
eelpwt atM
e l|at
burner capacity
Vb
t tmWmti
Hag
net Ie8t
reelwg
Mbb
net
yr Me Price
wf*
standard
"Sag
veal slat dtam. la.
Forced circulation unit* with fectory installed tankless neeter: No. 3 control tot -- T822D thermostat, U4124C Aouactat, reverse ano operating control, circulator retay RI184G light tensing primary control.
PFA-34-WT PFA-35-WT
PFA-36-WT PFA-37-WT
300 375 450
526
2.65
226
6.0
260.9
1739
S 961,00
3.30
232
7.5
326.1
2174
108SX0
3.95
445
9.0
391.3
2609
1219.00
4.60
445
9.0
457.4 3049
1338X0
905 1096 1287
1481
8 8 8 8
Forced circulation units less naater; No. a control sat -- TS220 tnarmostat, L40S1B Aquastat limit and circulator control
RB184G 119m Mining primary control.
PFA-34-W
PFA-35-W
PFA-3S-W PFA-37-W
300 2.65 375 3.30
450 3.95
526 4.60
260.9 326.1
391.3 4S7.4
1739 2174
2609 3049
f 911.00 1029.00 1147.00 126SX0
894
1085 1276 1470
8
8 8 8
STEAM
Steam units with factory Installed tankless heater: No. 2 control set -- TJ22D thermostat, PA404A Pretsuretroi, L4006A Aouastat operating control. R8104G llgnt sensing primary control.
PFA-34-ST
300
2.65 226 6.0 225.1
938 S 953.00
905 6
PFA-35-ST
375 3.30 232 7.5 281.3 1172
1080X0
1096
8
PFA-36-ST
450
3.95
445
9.0
337.6
1407
1211X0
1287
8
PFA-37-ST
526
4.60
445
9.0
394.6
1644
1330.00
1481
8
Steam units less neater: No. 2 control Mt-~T8220 thermostat, PA404A Pretsuretroi, R8284Q llgnt sensing primary control.
PFA-34-S
PFA-35-S PFA-36-S PFA-37-S
300 2.65 375 3.30 450 3.95 526 4.60
225.1
281.3 337.6 394.6
938 1172 1407 1644
S 899.00 1017.00
1135.00
1253.00
900 1091
1282 1476
8 8
8 6
'Nozzle sizes furnished with the above units: (S -- solid: H -- hollow) PFA-34. 2.50 fph 70* S; PFA-3S. 3-25 fph 45* 5; PFA-36, 4.00 fph 45* S. PFA-37. 4.50 fph 30* $.
tGellen* of water per minute heated from 40*F to 140*F with 200*F boiler water temperature.
Vent needs to extend only 3 feet above highest part of roof.
Standard Equipment
Water: ASME relief valve Pressure and temperature gauge
Flange mounted oil burner with 2-atage fuel unit; factory installed light sensing cad cell with bracket and lesda: V4046B
instantaneous oil valve; Syracuse elec tronic time delay; drain valve.
buttur-buniur unit
PFA-34 PFA-35
elf burner
LC-334-A3 LC-334-A
better-burner
PFA-361 PFA-371
ett burner LC-534-A
StMm: ASME safety valve Steam gauge Gauge glass with trimmings
Optional Equipment
Available in split assemblies. Specify on order. Added Trade Price ............ S17.00 For other optional equipment see page 24.
Units WITH water heater; 1 cover plate with \ " control tapping.
Units LESS water hester: 2 cover plates for heater openings.
Ordering Example*:
1. Pressure fired boiler-burner unit with *?oniord equipment with heoter for water: 1 PPA-34-WT boiler-burner unit
2. Pressure fired boiler-burner unit with op tional equipment leu heoter for iteom: 1 PPA-37-5 boiler-burner unit with jockef extension
je 52
Page 23
Zone valve packages are available for water boilers. For details and prices, see
page 34.
01540
PRESSURE FIRED BOILER-BURNER UNITS Wm AND STEAM
AMERICAN SiSTANDARD
HYDRONIC HEATING
PFA-3 OPTIONAL EQUIPMENT
Acoustically treated brown and beige jacket extension: Jacket extension provides 1714' enclosure in front for con cealment of oil burner and controls. Approximate shipping weight 42 lbs. Specif? on order. Added Trade Price... >40.00
No. S-Z control set for circulator zoning with PFA-3 boilerburner units equipped for tankless heater. 1 No. 5-Z set is required for each zone in addition to the first zone which is controlled by the No. 6 control set or equivalent. Trade Price of ............................................................................. >27.75
McDonnell & Miller No. 67AR low water fuel cut-off for quick hook-up installation is available for PFA-3 steam units at added Trade Price of........................................ $33.00
McDonnell & Miller No. 63 low water cut-off is available for PFA-3 water units at added Trade Price of......... >45.25
Controls and control sets are shown on page 36.
I=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR PFA-3
Heaters tested with boilers. Built-in tankless heaters can be ordered for separate shipment with units or boilers specified less heater as follows:
Wfllt
PFA-34 PFA-35 PFA-36 PFA-37
bwmpr (city
A
2.65 3.30 3.95 4.60
a*.
226 232 445 445
laWaH rtb*
MM,
IlMR
6.0 6.0 7.5 7.5 9.0 9.0 9.0 9.0
CallR> of wt*r par wtrtvf* from 4C*P to 140*P wills ?00*F bailor wetor tompororwo.
fhr* liiin nN flaw
23 pti 36 psi 37 pti 37 psi
TfW* Prlcb
>42.00 51.00 65.00 55.00
HH-1 2 3 6 r
Page 24
01541
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
PFA-5 Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 80% efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure is optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. 5 Vent neeua to eAltrnu uiuy 3 feei above highest part of roof.
BOILER-BURNER UNITS STEAM ANO WATM
Fmwn find b*iif hwmw unit iwmka
it
rtu
wtpwt MM
PFA-504-* 0(T) PFA-S05-* 0(T) PFA-506-* 0(T)
PFA-507-* 0(T) PFA-508-* 0(T) PFA-509-* 0(T)
620 786 950
1116 1282 1446
PFA-S10-* 0{T) PFA-511-* OfT) PFA-512-* OfT)
1612 1776 1944
PFA-513-* 0(T) PFA-514-* OfT) PFA-515-* 0(T)
PFA-516-* OCT) PFA-517-* 0(T) PFA-516-* 0(T)
2108 2272 2440
2604 2768 2936
PFA-51#-* 0(T) 3100 PFA-520-* 0(T) 3260 PFA-521-* OfT) 3430
bvmpr capacity
41
5.45 6.90 8.35
9.80 11.20 12.65
14.10 15.55 16.95
18.40 19.85 21.25
22.70 24.15 25.60
27.00 28.45 29.90
plolog o*4 pickup factor
SIM
wafer
not 1 m | 1 rating
Mbh tlcmw
Bloofmt-
1.333 1.333 1.333
1.333 1.330 1.315
1.15 465.1 539.1 1.15 589.6 683.5 1.15 712.7 826.1
1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099.6 1257.4
1938 2467 2969
3488 4016 4582
1.302 1.292 1.288
1.15 7238.1 1401.7 1.15 1374.6 1544.3 1.15 1509.3 1690.4
5159 5728 6289
1.288 1.288 1.288
1.288 1.288 1.288
1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7
1.15 7021.7 2264.3 1.15 2149.1 2407.0 1.15 ^279.5 2553.0
6819 7350 7893
8424 8954 9498
1.288 1.288 1.288
1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6
10028 10546 11096
Mt rating aq. H. wafer
3594 4557 5507
6469 7432 8383
9345 10295 11269
12220 13171 14145
15096 16047 17020
17971 18899 19884
Trod* Pr'co with itmdord quipofeot
oH
not i dim*. la.
$1490.00 10 1764.00 10 1964.00 10
2280.00 10 2529.00 10 2709.00 14
3173.00 14 3689.00 14 3962.00 14
4144.00 14 4358.00 14 4662.00 14
5013.00 18 5227.00 18 5509.00 18
5760.00 18 5980.00 18 6186.00 18
Oppt--* knot*
ahtpplog -v`ht
burner m*d*i iwpplid with tiondord *qwipm*at
1840 2210 2520
95A-1-6702-JBT
96A-M-6131-JC-T 96A-M-6131-JC-T
2880 3190 3550
96A-B-8316-JC-T 96A-B-6318-JC-T 96A-B-8318-JC-T
3935 4285 4845
96A-T-A-8419-JC-T 97A-T-A-6614-JC-T 97A-T-A-8614-JC-T
4955 5317 5875
5985 8345 5750
97A-T-A-8614-JC-T 97A-T-A-8615-JC-T 97A-T-2-7635-E-1
97A-HM.O-2-7685-E-1 97A-HM.O-2-7685-E-1 98A-HI-L0-2-7771 -E-1
7060 7420 7780
98A-Hi-L0-2-7771 -E-1 98A-H1-L0-2-7771 -E-1 98A-HI-L0-2-7771 -E-1
The n*' I --S_t rating! shown art band on piping and pick.up allowances listed abort. American.Standard should ba consulted boforo selecting a boiler for installations hoving unusual piping and pick-up requirements.
-Subetitute loner "S" for steam: "W" for water. Stert Up end One Year's Service ... Price on Application Suffix (T) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heatan, sec page 28.
W Nome sires, gph, furnttned witn the above oit burners are as toitows:
mit m. gph. typ*
wait a*. gph. typ*
wait n*. gph. typ*
Wflit IW. ppA- *yp
waH m. gph* typ*
wait M. gph. typ*
PFA-504 2 2.75 90*H PFA-505 2 3.50 90* H PFA-506 2 4.00 80* H
PFA-507 1 4.50 70*H
1 5.00 70*H PFA-508 2 5.50 80'H
PFA-509 1 6.00 80 *H PFA-512 2 7.00 70*H PFA-514 1 3.50 60* H PFA-517 1 10.00 90* S PFA-620 1 6.00 80'S
1 6.50 80*H
1 2.50 70 *H PFA-515 2 8.00 70*H PFA-618 1 7.50 90 *S
1 8.50 80'S
PFA-510 2 5.50 90*H PFA-513 2 7.00 70*H
1 5.00 70* H
1 8.00 90*S
1 12.00 80* S
1 2.75 90* H
1 4.00 70*H PFA-515 2 7.00 90*S
1 10.00 90*S PFA-621 2 8.00 80*S
PFA-511 2 6.50 80* H
1 8.50 90*S PFA-519 2 7.50 80*S
1 14.00 80 *S
1 2.00 80* H PFA-514 2 8.00 60*H PFA-517 2 7.00 90*S
1 12.00 B0*S
Standard Equipment--All Boilera
Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve.
Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve.
Standard Equipment--Oil Fired Flange mounted oil burner--97A-T-A, 97A-T-2, 97A Hi-Lo and 98A Hi-Lo burners furnished with flange and pedestal; 2-stage fuel unit. On 95A-1, 96A-M, 96A-B, 96A-T-A and 97A-T-A burners, factory installed cad cell, bracket and leads, R8185E light sensing primary control; V4046B in stantaneous oil valve, ST70A1002 electronic time delay. On 97A-T-2, 97A Hi-Lo-2 and 98A Hi-Lo-2 burners, R4150A control--provides pre-purge and post-purge, Q520A base, factory installed C7013A photo cell; delayed and instantan eous oil vsive;, nozzles.
Standard r.'oro- Voltages
PFA-oOf thru PFA-510 PFA-611 ttm PFA-621
115/60/1 230/60/1
Ord*rinq Examples:
PfA-S boiler-burntr unit for steam with standard oquipmont.
-P*A-5W-SO boiler-burner unit
*tA-5 ffO'ij'-burnor unit for water with opti.' f'1 equipment.
I --Ff , i -WOrT) with laeket extension; 4 iWn.
tankless
htotwri; v/ith 16006A control.
Optional Equipment--Oil Fired
Oil Burners equipped to meet F.M. and Massachusetts Code requirements for PFA-504 through PFA-614 Units are available when specified on order. Added Trade Price...................................................... $169.00 Burners for PFA-515 through PFA-521 already equipped to meet F.M. requirements. Equipment includes: R41E0A pro vides pre- and post-purge, C7013A Photo Cell and Q520A Base. Oil Burners to meet F.I.A. requirements--Price on applica tion. Oil burners for PFA-515 thru PFA-521 to meet Massa chusetts Code requirements -- Price on application.
Prewired Control Panels on burners - prices on application.
Optional burners available forPFA-504 thru PFA-E10, see page 28.
See page 52
Page 25
HH-12
01542
GAS boiler-burner units
STEAM AND WATER
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
PFA-S Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 80% efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure is optional at caua cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant Excellent boiler water circulation in steam boilers assures fast steaming and good
steam quality.
Vent needs to extend only 3 feet above highest part of roof.
prauwra firW biif-burnt unir wumbar
rwi 1 a wr
ut*1vt Mhh
Isl-t bwenar i input Mb*
piping on4 pickup foe ton worn
nvf Ib| c| rosing
Mb* iion wator
I*. He tlatfn
Mf rating H H. woitar
PFA-504-* G(T) PFA-505-* G(T) PFA-506-* G(T)
PFA-507-* G(T) PFA-508-* G(T) PFA-509-* G{T)
PFA-510-' G(T) PFA-511-* G(T) PFA-512-* G(T)
PFA-S13-* G(T) PFA-514-* G(T) PFA-515-' G(T)
PFA-516-* G(T) PFA-S17-* G(Tj PFA-518-* G(T)
PFA-519-* G(T) PFA-520-* G(T) PFA-521-* G(T)
620 786 950
1116 1282 1446
1612 1776 1944
2108 2272 2440
2604 2768 2936
3100 3260 3430
763 966 1169
1372 1568 1771
1974 2177 2373
2576 2779 2975
3178 3381 3584
3780 3983 4186
1.333 1.333 1.333
1.333 1.330 1.315
1.302 1.292 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.15 465.1 539.1 1.15 589.6 683.5 1.15 712.7 826.1
1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099.6 1257.4
1.15 1238.1 1401.7 1.15 1374.6 1544 3 1.15 1509.3 1690.4
1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7
1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0
1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982 6
1938 2457 2969
3468 4016 4582
5159 5728 6289
6819 7350 7893
8424 8954 9498
10028 10546 11096
3594 4557 5507
6469 7432 8383
9345 10295 11269
12220 13171 14145
15095 16047 17020
17971 18899 19884
Trwda fries with Hipsdfd qwipmanf
$2349.00 2881.00 2803.00
3133.00 3390.00 3579.00
4081.00 4814.00 4027.00
8126.00 5340.00 5544.00
5887.00 5101.00 5294.00
6691.00 6883.00 7108.00
Fftw* Imato
is* hipping atom. weight
in.
bvntof modal wppliad with standard aquipmanf
10 1840 R6.2-G-03-R4795-B 12S 10 2210 R6.2-G-03-R4795-B. 12S 10 2520 R6.2-G-03- R4795-B. 12
10 2880 R8-G-05-R4795-B.12 10 3190 R8-G-05-R4795-B.15 14 3550 R8-G-05-R4795-B.15
14 3935 R8.1-G-05-R4795-B.20 14 4285 R8.2-G-05-4150A-H.20 14 4645 R8.3-G-10-4150A-H.20
14 4955 R10.9-G-10-4150A-H.20 14 5315 R10.9-G-10-4150A-H. 20 14 5675 R10.9-G-10-4150A-H.20
18 5985 R10-G-15-4150A-H.25S 18 6345 R10-G-15-4150A-H.25S 18 6750 R10.1-G-15-4150A-H.26S
18 7060 R10.1-G-20-4150A-H.25 18 7420 R10.1-G-20-4150A-H.26 18 7780 R10.1-G-2tM150A-H.26
Tha n*t | --6--R rotir>g shewn are bated an piping and pick>up allowance* listed above. American-Standard should be consulted before selecting a boiler far installations having unusual piping and pick-up requirements.
* Substitute letter "S" for steam; "W" for woter. START-UP AND ONE YEAR'S SERVICE: INCLUDED IN TRADE PRICE OF GAS UNIT.(I) Suffix (T) denotes boiler with openings in center section for tankless heaters when specified. For Built-in Water Heaters, see page 28.
Standard Equipment--All Boiler! Steam: PA404A Pressuretrol. ASME safety valve, steam
gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat. ASME relief valve, pressure and
temperature gauge, drain valve.
Standard Equipment--Gat Fired Flange mounted gas burner. Standard burner controls meet latest UL requirements. Dual automatic gas valves for add ed reliability. Gas-electric ignition. Electronic program ming controls and components are factory wired in a con trol cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burners equipped to operate with 1,000 Btu, 0.6 specific gravity natural gas.
Ordering Examples: PFA-S boiler-burner unit for steam with standard equipment. 1 --PFA-514-SO boilet-butner unit PFA-S baiier-burner un,t For water with optional equipment. 1--PFA-Sll.WGCT) with jacket extension; 4 No. 549 tankless heaters. Specify gas pressure available at gas train inlet.
(1) Surcharge for Start-Up and Service west of Mississippi River. Contact American-Standard for details.
The comple. n*;ure of th, Cm and Gej-Oil Burners make them imprac
tical lo since at b. nd Plant Therefore please allow 3 10 4 weeks i*d
time fc `iftipment of SLjnatrd Equipped Burners after receipt of order
et Hyuromc Order
Center.
Optional Equipment
Factory assembled sections available. Specify on order.
Added Trade Price -- Per section
$22.00
PFA-5 units are available with controls to meet Factory
Mutual and Factory Insurance Association minimum
requirements at the following added charges:
got fired
bailor lisa
F.M.
--------
F.i.A.
PFA-504--510
$753.00
$928.00
PFA-511--515 PFA-516--521
573.00 596.00
826.00 854.00
For prices of gas burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office.
High Risk F.M. or F.I.A. requirements......
Hi-Lo Fire Control .......................................
Modulating Fire Control --......................
Alarm System pre-wired and mounted on control cabinet............................................
Optional Combustion Controls ......................
^
on ^ ,ea,l0n
Controls to meet local requirements .......... For Additional Optional Equipment, See page 28.
Standard Motor Voltages
go* bvmvc*
PFA-504-511 PF A-512--521
115-60-1 230-60-3
Other optional motor voltages--Price on Application.
HH-12 ^ See race 52
Page 26
01543
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
PFA-5 Pressure Fired Boiler-Burner Units are equipped with burners designed and tested for over 80^ efficiency and outstanding performance. Combustion chamber and separate base are not required due to wet base design. Minimum stack required making boiler ideal for replace ment. Boiler is tested and equipped for 50 lbs. water working pressure; 80 lbs. water working pressure optional at extra cost. Perfect seal between boiler sections, between canopy and section assembly and between pressure relief door and back section is attained with durable sealant. Excellent boiler water circulation in steam boilers assures fast steaming and good steam quality. Vent needs to extend only 3 feet above highest part of roof.
GAS-LIGHT OIL
BOILER-BURNER UNITS STEAM AND WATER
pmivt* fired betler burner
go*--light oil
1 Blast
grot* Islet
burner capacity
output Mbh
.get
Mb*
piping end atom* water
net e | s | rating
iteam water
ad. ft. ateam
net
''Trade Price with itowdord
rent
approx imate
equipment
NooWf
4lm. weight
per--ell
burner medei auppHed wttb atowdord equfpmern gat - oil
PFA-504-* GOfT) PFA-505-* GOfT) PFA-506-* GO(T)
620 763 786 966 950 1169
PFA-507-* GOfT) 1116 1372 PFA-508-* GOfT) 1282 1566 PFA-509-* GOfT) 1446 1771
PFA-510-* GOfT) 1612 1974 PFA-51T-* GOfT) 1776 2177
PFA-512-* GOfT) 1944 2373
PFA-513-* GOfT) 2108 2576
PFA-514-* GOfT) 2272 2779 PFA-515-' GOfT) 2440 2975
PFA-516-* GOfT) 2604 3178 PFA-517-' GOfT) 2768 3381
PFA-518-* GOfT) 2936 3584
PFA-519-* GOfT) 3100 3780 PFA-520-* GOfT) 3260 3983
PFA-521-* GOfT) 3430 4186
1.333 1.333 1.333
1.333 1.330 1.315
1.302 1.292 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.15 465.1 539.1 1.15 589.6 683.5 1.15 712.7 826.1
1938 2457
2969
3594 $2762.00
4557 2993.00 5507 3292.00
1.15 837.2 970.4
1.15 963.9 1114.8 1.15 1099.6 1257.4
3488 4016 4582
6469 7432 8383
3564.00
3899.00 4080.00
1.15 1238.1 1401.7 1.15 1374 6 1544.3 1.15 1509.3 1690.4
5159 9345 5728 10295 6289 11269
4S92.00 4971.00 5352.00
1.15 1636.6 1833.0
1.15 1764.0 1975.7 1.15 1894.4 2121.7
6819 12220 7350 13171 7893 14145
5554.00 5759.00
5972.00
1.15 2021.7 2264.3 1.15 2149.1 2407.0
1.15 2279.5 2553.0
8424 15095 8954 16047
9498 17020
6312.00 6527.00
6802.00
1.15 2406.8 2695.7 10028 17971 1.15 2531.1 2834.8 10546 18899 1.15 2663.0 2982.6 11096 19884
7132.00 7415.00
7640.00
10 10 10
10 10 14
14 14 14
14 14 14
18 18 18
18 18 18
1840 R6.2-GO-03-R4795-B.12S-FIC 2210 R6.2-GO-03-R4795-8.12S-FIC 2520 R6.2-GO-03-R4795-8.12 FIC
2880 R8-GO-05-R4795-B. 12-F3 3190 R8-G0-05-R4795-B.15-F3 3550 R8-GO-05-R4795-B. 1S-F3
3935 R8.1-GO-05-R4795-8.20-F3 4285 R8.2-GO-07-4150A.H.20-F4H 4645 R8.3-G 0-10-4150A-H.20-F4H
4955 R10.9-GO-10-4150A-H. 20-F4H 5315 R10.9-GO-10-4150A-H.20-F4H 5675 R10.9-GO-10-4150A-H.20-F4H
5985 R10-GO-15-41S0A-H.25S-F4H 6345 R10-GO-15^150A-H.2SS-F4H 6750 R10. l-GO-20-4150A-H.25S-F4H
7060 fl 10.1-GO-20-4150A-H.25- F4 H 7420 R10.1-GO-30-4150A-H.25-F4H 7780 R10.1-G0-3O4150A-H. 25-F4H
Tho not I u t r (i rafingi shown ora baled on pioing and pick-up allowances lilted above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements.
Substitute letter "S" for steom, "W" for water. START-UP AND ONE YEAR'S SERVICE; INCLUDED IN TRADE PRICE OP GAS-OIL UNIT.(I) Suffix IT) denores boiler with openings in center section for tankless hooters when specified. For Built-in Water Heaters, see page 26.
Standard Equipment--All Boilers Steam; PA404A Pressuretrol, ASME safety valve, steam
gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat. ASME relief valve, pressure and
temperature gauge, drain valve.
Standard Equipment--Gas-light Oil Fired
Flange mounted combination gas-oil burner. Standard burner controls meet latest UL requirements. Manually operated fuel switch for dual fuel change-over. Dual auto matic gas valves for added reliability. Gas-electric ignition.
Electronic programming controls and components are fac tory wired in a control cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burner equipped to operate on No. 1 or No. 2 fuel oil and 1,000 Btu, 0.6 specific gravity natural gas.
Standard Motor Voltages
uni'
ge*eil bdfMn
PFA-504--510
115-60-1
PFA-511 PFA-512-521
230*60-1 230-60-3
Other optional motor voltages--Price on Application.
ID Surcharge for Start-Up and Service weft of Mississippi River. Contact Amcricon-Stondord for details.
Ordering Exempt**:
PFA-5 boil*f-bv'nr unit for iteom with standard equipment.
1 -- PFa-5 14-SOO boiler-burner unit.
PFA-5 bol-* *
untt for weir with opfionol equipment.
PFA il*. VGOlTj with jacket extension; A No. 548 lenkleis
hoofu':.
Spocrfy 901 p-eiivr* ovoilobl# at got from inlet.
Nozzle sizes, gph, furnished with combination ges-fignt oil burners ere es follows: (nozzlecapacity is dependent on oh pressure.)
vail ne. gph. type
unit ne. gph. type
unit ne. gph. type
PFA-504 1 4.00 90H PFA-505 1 5.00 90H PFA-506 1 6.50 90H PFA-507 2 4.00 90S PFA-508 2 4.00 90S PFA-509 2 5.00 90S
PFA-510 2 5.00 90S PFA-511 2 5.50 90S PFA-512 2 6.00 90S PFA-513 2 7.00 60S PFA-514 2 7.00 60S PFA-515 2 7.00 60S
PFA-516 2 7.00 60S PFA-517 2 8.00 60S PFA-518 2 8.00 60S PFA-519 2 8.00 60S PFA-520 2 8.50 60S PF A-521 2 9.00 60S
Optional Equipment
PFA-5 units are available with controls to meet Factory Mutual and Factory Insurance Association minimum requirements at the following added charges:
peewit fired
belief site
P.M.
P.I.A.
PFA-504--510 PFA-511-515 PFA-516-521
$938.00 753.00
775.00
$1079.00 994.00
984.00
Automatic Fuel Changeover Trade Priced........................................................$194.00
For prices of gas-oil burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office.
High Risk F.M. or F.I.A. requirements.......
Hi-Lo Fire Control.........................................
Modulating Fire Control.................................... Price
Alarm System pre-wired and mounted on control cabinet.............................................
on
Optional Combustion Controls....................... Application
Controls to meet local requirements ..........
Th complex nature of the Gee end Cee^Oi) Burner* make them imprac tical to aLock at Bond Plant. Therefore, pleeee allow 3 to 4 week* lead time for ahiDment of Standard Equipped Burner* after receipt of urder et Hydronic Order Service Center.
r See oage 52
age 27
01544
BOILER-BURNER UNITS OIL FIRED BOILERS
WATTS AND STEAM
rSl AMERICAN LSi STANDARD
HYDHONIC HEATING
PFA-5 OPTIONAL EQUIPMENT
Jacket extension: Jacket efleftsion provides 34 >4" enclosure in front for concealment of burner and controls. Approxi mate shipping weight 90 lbs. Specify on order. Added Trade Price ...................................................................... $67.00
PFA-5 boilers tested for 80 lbs. water working pressure: available when specified on order. Add to Trade Price of water boiler...................... ............................... $8.50 per section
Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows:
PFA-5 ................................ Trade Price each..................... $4.10
Optional oil burners to provide low fire start (with cad cell) for PFA504 thru PFA508; Hi-Lo operation provided (with cad cell) for PFA509 and PFA510. Please allow four weeks lead time after receipt of order at the hydronic order service center.
wdi
PFA 504 PFA 505 PFA 506 PFA 507 PFA 508 PFA 509 PFA 510
burner tnedeJ
96A-T-A-8406 JBT 96A-T-A-8408 JBT 96A-T-A-8408 JCT 96A-T-A-8409 JCT 96A-T-A-8410 JCT 96A-HI LO-A-8808 JCT 96A-HI LO-A-8808 JCT
^4 la Trade Price
$134.00 126.00 126.00 60.00 60.00 271.00 210.00
Factory assembled sections available. Specify on order.
Added Trade Price per section ....................
$22.00
*)
TANKLESS WATER HEATERS FOR A-5, FRA-5 ANO PFA-5
Tankless water heaters are available in any quantity at the following Trade Prices:
Ketci wwwhgr uftod with
prti. drop at ratod flow
Trod* Price eecfc
530 A-5. FR-A-5 548 PFA-5
15 psi 16 psi
$42JO 70J0
PFA-5 units with tankless water heaters require additional controls at current prices as follows:
STEAM: L4006A Aquastat operating control.
Trade Price .
$14.90
WATER: L6006A Aquastat operating and circulator
control.
Trade Price ...... $15.80
Factory assembled copper pipe manifold for parallel hook up of multiple heaters are available as follows:
emnrield
Trade Price* fee A-S. rt-A-S
2 Hutir...............................................................$ 0.70 3 Huttr............................................................... 12.70
........................................................................ 16JO
When suffix "T" is added to boiler number on order for A-5, FR-A-5 or PFA-5 boilers or units, maximum number of center sections with water heater openings are furnished at no extra charge as follows: Except where noted by asterisk in which case max. number of openings minus one is furnished unless max. number is specified on order.
A-S ed Fl-A-J feeder
A-S or FR-A-504-T A-5 or FR-A-50S-T thru 507-T A-5 or F R-A-508-T*thru 509-T A-5 or FR-A-510-T*thru 511-T*
me*. ne. et
2 3 4 5
PFA-3 belter
PFA-504-T PFA-505-T thru 506-T PFA-507-T thru 508-T PFA-509-T thru 511-T
mi. ne. el evening*
1 2 3 4
PFA-S belief
PFA-512-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PFA-520-T thru 521-T
met. ne. el
evening*
5 6 7 8
The following table shows ratings attained if more than one heater ia connected in parallel:
tenkleu Kenter ne. 1J0
tonMetc Keefer Ne. 541
beilw wmWr
ne et Keeler*
raftng gem.
better number
ne ef Keeieri
A-5 or FR-A-5-T all sizes A-5 or FR-A-5-T all size*
A-5 or FR-A-505-T thru 511-T A-5 or FR-A-508-T thru 511-T A-5 or FR-A-510-T thru 511-T
1
2 3 4
5
4 PFA-5-T all size* 7 PFA-505-T thru 506-T 10 PFA-507-T thru 508-T 13 PFA-509-T thru 511-T 16 PFA-512-T thru 514-T
PFA-515-T thru 517-T PFA-518-T thru 519-T PFA-520-T thru 521-T
1
2 3 4
5 6 7
8
*Gollni of oi#' Mr mmol* ronotf from d0*F to ld0*F *ith 200*F feeder woier femeererwre.
rating fpen.
8 16 24 32 40 48 56 64
HH-12
MeDONNELL & MILLER LOW WATER CUT-OFFS STEAM: No. 369 Low Water Cut-off for A-5, FR-A-5, PFA-6 ............................
No. 47-2 Feeder and Cut-off for A-6, FR-Ar5, PFA-604 thru PFA-609 No. 51-2 Feeder and Cut-off for PFA-510 thru PFA-521 ....................... WATER--50 PSI: No. 63 Low Water Cut-off for A-6. FR-A-6 and PFA-5........ WATER--0 PSI: No. 150 Low Water Cut-off for PFA-6 ..................................
Page 28
Tro*. M"
8 27.00 77.00
100.00 45.25 88.00
01545
(^AMERICAN caSTANDARD
HYDRONIC HEATING
boiier-burner units
WATK AND STiAM
FR A-5 FUME RETENTION BOILER-BURNER UNITS
The FR-A-5 is a perfect combination of boiler and burner teamed for top performance. Develops 12)4 COz. Tested and equipped for SO lbs. water working pressure. Motors and controls regularly furnished are for 115 volt, 60 cycle power supply.
WATER
boiler-burner unit number
output Mbh
bumor capacity
IP*
not rating Mb*
not ratine 4. ft orator
Trade Prico ortth standard equipment
For Built-in Water Heaters, Steam and Water Boilers, see page 28.
stripping weight
chtiminnoy
FR-A-504-WB(T) FR-A-505-WBfO FR-A-506-WB(T)
FR-A-507-WBfn FR-A-508-WB(T) FR-A-509-WB(T)
FR-A-510-WB(T) FR-A-511-WB(T)
384 472 560
648 736 824
912 1000
3.55 4.30 5.10
5.90 6.70 7.45
8.25 9.05
333.9 410.4 487.0
563.5 640.0 716.5
793.0 869.6
2226 2736 3246
3756 4266 4776
5286 5797
$1087.00 1204.00 1405.00
1535JO 1681.00 1522J0
1854.00 2085.00
1576 1827 2110
2367 2626 2890
3144 3392
12 x 12 x 15 12 x 12 x 20 12 x 12 x 20
12 x 16 20 12 x 16x20 12 x 16 x 20
16 x 16x20 16 x 16x20
HI
MBBi
BOI
QHEfl SHUH
BFj
VL1
E*!
r
STEAM
boller-bumer unit numbor
FRA-504-SBCT) FR-A-505-SBfD FR-A-506-SB(D
FR-A-507-SB(T) FR-A-508-SBfT) FR-A-509-SB(T)
FRA-510-SB(T) FR-A-511-SB(T)
greet
Iwgwft
output Mbh
burner
0*capacity
384 472 560
648 736 824
912 1000
3.55 4.30 5.10
5.90 6.70 7.45
8.25 9.05
!!not It rating
Mbh
4. ft team
288.1 354.1 420.1
486.1 552.1 618.2
684.2 750.2
1200 1475 1750
2025 2301 2576
2851 3126
Trade Price with standard equipment
$1087JO 1204.00 1405.00
1535.00 1S85J0 1822.00
1954.00 2085.00
approx. hipping
wight
dnehlmnoy
1577 1828 2112
2369 2628 2892
3147 3395
12 x 12 x 15 12 x 12 x 20 12 x 12 x 20
12 x 16 x 20 12 x 16x20 12 x 16 x 20
16 x 16 x 20 16 x 16x20
-Nozzle sizes. Iph. furnished with the ebove units: FR.A-504. 2 1.75 SO* H: FR-A-505, 1 2.00 & 1 2.25 SO- H: FR-A-S06. 1 4.00 70- S (200 Psi*:) FR-A-507. 1 4 50 70- S (200 Psig); FR-A-SOS. 1 3.25 A 1 3.50 70- S: FR-A-509. 1 3.50 A 1 4.00 70" S; FR-A-510. 2 4.00 70* S; FR-A-511. 2 4.50 70- S.
Suffix "T" danotas unit with openings in center uetiona for tanklaaa haatara. Start-up and on* year aervlct avallabla. Price on application.
Standard equipment Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing cad cell, bracket and leads; R8184G light sensing primary control. Delayed oil valve except on model 92A-7240-D and 92A-7242-D oil burners.
boiler-burner unit number
FR-A-504 FR-A-505 FR-A-506, FR-A-507 FR-A-508
oil bunwr
92A-7240-D 92A-7242-D 95A-300-7468-D (200 Psig fuel unit) 96A-M-7498-D
bolier-bumor unit number
FR-A-509 FR-A-510, FR-A-511
Draft regulator Drain valve
II bumtr
96A-M-7546-B 96A-M-7548-B
Water No. 3 control set:
ASME relief valve
T822D thermostat
Pressure and temperature
L4080B Aquastat limit gauge
control Nozzle (s)
Steam: No. 1 control set: T822D thermostat PA404A Pressuretrol Nozzle(s)
ASME safety valve Steam gauge Gauge glass with trimmings
Optional Equipment
Jacket extension: Jacket extension provides 25* enclosure in
front for concealment of oil burner and controls. Approxi
mate shipping weight 57 lbs. Specify on order. Added Trade
Price
......................................................... *43.50
Cover plate required to close unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows:
Trade Price each .......................................................... $4.25
For Factory Mutual Approval and Massachusetts code requirements, special electronic flame safeguard controls are available, with RA890 Protectorelay, W415A control panel (includes Q270A base and R488F switching relay), C7013A photocell. Delayed oil valve.
oil heating unit
bumir modal
added Trado
Price charge__
Control sets other than those included in Trade Price of FR-A-5 boiler-burner units will be furnished on order at the following added charges:
Control St
added charge
Steam control set No. 2 Water control set No. 4 ....................
Water control set No. 5 ................. `Water control set No. 5-Z ..................
SI 4.80 11.65
23.75 27.75
FR-A-504 FR-A-505 FR-A-506. FR-A-507 FR-A-508 FR-A-509 FR-A-510. FR-A-511
92A-7240-L 92A-7242-L 95A-300-7468-L 96A-M-7498-L 96A-M-7546-L 96A-M-7548-L
$162.00 162.00 142.00 162.00 155.00 155.00
(Add-on zona. Usa only with No. 5 Control Sat. Tha No. 5-Z control sat for circular zomnf on unit! with tankless htatars.)
Ordering Examples:
1. Boiler-burner unit with standard equipment: 1 FR A 506 SB oil heating unit. 2. Boiier-burner unit for steam with optional equipment: 1 FR-A-509 SB T with No
control set; 3 No. 530 tankless heaters; 1 3-heater manifold.
See oaae 52
Page 29
HH-12
015'
FLAME RETENTION BOILER-BURNER UNITS WATER AND STEAM
jAMERICAN la STANDARD
HYORONIC HEATING
FR-A-7 FLAME RETENTION BOILER-BURNER UNITS
The perfect combination of boiler and burner teamed for top performance develops lZbi% COj. Available with or less jacket. Tested and equipped for SO lbs. water working pressure. Onerstine controls furnished for 115 volt, 60 cycle povrer supply.
WATER
boiiar^umar unit numbtr
FR-A-706-WO-B FR-A-707-WO-B FR-A-708-WO-B
FR-A-709-WO-B FR-A-710-WO-B FR-A-711-WO-B
FR-A-712-WO-B FR-A-713-WO-B FR-A-714-WO-B
cmi lo-u8tpuftt
Ubh
1-8-R bumor capacity
*ph
not l-8R rating
Ubh
ppiipcikn>gup4 factor
nat rating q. ft orator
unjackatad
lackatod
'Trad# Prleo approa. Trada Prfca approa. with standard Shipping with standard shipping oquipmont woight oquipmont woight
chlmnoy six#
1160 1376 1580
1812 2020 2228
2440 2720 3000
10.55 12.30 14.15
16.35 18.15 20.20
21.95 24.10 26.30
1008.7 1196.5 1373.9
1575.7 1756.5 1937.4
2121.7 2365.2 2608.7
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
6724 7976 9159
10504 11710 12916
14144 15768 17391
*2377.00 2621.00 3114.00
3332.00 3675.00 3911.00
4S03.00 4726.00 5054.00
4968 5626 6439
7223 7910 8558
9264 9950 10678
*2505.00 2768.00 3279.00
3614.00 3674.00 4126.00
4738.00 4976.00 5324.00
5144 5814 6750
7445 8149 8814
9534 10240 10988
16 x 16x30 16 x 20 x 35 16 x 20 x 35
20 x 20 x 40 20 X 20 x 45 20 x 20 x 55
20 x 24 x 60 20 x 24 x 70 24 x 24 x 80
STEAM
bailor^umor unit numbar
FR-A-706-SO-B FR-A-707-SO-B FR-A-708-SO-B
FRA-709SO-B FR-A-710SO-B FR-A-7 U-SO-B
FR-A-712-SO-B FR-A-713-SO-B FR-A-714-SO-B
gross IwBaR output
Ubh
IkBkR bumor capacity
gph
not IbIbR rating Mbh sstoo-ofmt
A unjackal ad
Jackatiu
piping A pickHJp factor
Trada Prtea with standard OQuipmant
approa. Trada Pries shipping with standard woight oquipmont
approx. hipping woight
chlmnoy sixa
1160 1376 1580
1812 2020 2228
2440 2720 3000
10.55 12.30 14.15
16.35 18.15 20.20
21.95 24.10 26.30
870.2 1041.6 1211.7
1403.6 1568.3 1729.8
1894.4 2111.8 2329.2
3626 4340 5049
5848 6535 7208
7893 8799 9705
1.333 1.321 1.304
1.291 1.288 1.288
1.288 1.288 1.288
*2377.00 2621.00 3114.00
3332.00 3675.00 3911.00
4503.00 4725.00 5054.00
4970 5629 6441
7228 7915 8560
9266 9952 10680
*2505.00 2768.00 3279.00
3514.00 3574.00 4128.00
4738.00 4979.00 5324.00
5146 5817 6752
7450 8154 8816
9536 10242 10990
16 x 16x30 16 x 20 x 35 16x20x35
20 x 20 x 40 20 x 20 x 45 20 x 20 x 55
20 x 24 x 60 20 x 24 x 70 24 x 24 x 80
*Amaricar>Standard should bt consulted before selecting on FR boiler-burner unit for installations having unusual piping and pick-up requirements.
eNoie sues. gph. furnished with the above units: FR-A-706. 1 5.00 & 1 5.50 *0* S: FR-A-707. 2 6.00 60* S: FRA-708. 1 2.00 A 2 6.00 90* S:
FR-A-709. 1 3.00 fc 2 6.50 90* S: FR-A-710. 2 9.00 70* S; FR-A-711. 2 10.00 70* S; FR-A-712. 2 6.00 4 1 10.00 80* S; FR-A-713. 2 6.00 & 1 12.00 80*
S. FR-A-714 18006 2 9 00 60 S.
Surt-up and one year service available. Price on application.
Standard equipment:
Pedestal mounted oil burner with 2-stege fuel unit; on 96A-M-7543-B and 9708111-B burners, factory installed cad cell, bracket and leads: R8184B light sensing primary control. On 96A-T burners, RA890 Protectorelav and Q270A base, C7013A photocell; on 97A Hi-Lo and 98A Hi-Lo burners, R4150A Flame Safe guard control -- provides prepurge and postpurge, Q520A base, C7013A photocell. Delayed oil valve (2 with 96-A-T). Delayed and instantaneous valves with 97A Hi-Lo and 98A Hi-Lo.
bil.reumr unit number
oil bumor
standard motor valtaga
FR-A-706, FR-A-707 FR-A-708 FRA-709 FR-A-710. FR-A-711 FR-A-712. FR-A-713 FR-A-714
12M cast iron bass on all units,
96A-M-7543-B
115/60/1
96A-T-7935-K
115/60/1
96A-T-7937-K
115/60/1
970-8111-B
115/60/1
97A Hi-Lo-7673-E 98A Hi-Lo-7773-E
230/60/1 230/60/1
In addition. I" high stoat padastal basa is Turnishad with S
through 14 soction units.
Draft regulator.
Water L4080B Aquastat limit control Steam: PA404A Pressuretrol
Nozzles
Nozzles
ASME relief valve
ASME safety valve
Pressure and temperature eauge
Steam gauge
Optional equipment: See page 33.
Gauge glass with trimmings
Combustion chambar not furnished. See Installation-Operation end Maintenance Manual for combustion chambers required far FR-A-7 boiler-burner unite.
Nete: For Optional Electronic Flame Safeguard Control Equipment, See Page 33.* 1 2
Ordering Eiampies:
1. Boiler-burner unit for steam jacketed with standard equipment 1 FR-A-710-S0-B boiler.burner unit
2. Boiler-burner unit for water less ticket with optional equipment: 1 FM-707-W0-B boiler-burner unit with electronic 'leme safeguard controls to meet Factory Mutual Approval.
HH-12 w See sage 52
Page 30
01547
dAMERi'..' STANDAKL
HYDRONIC HEATING
OIL FIRED BOILERS WATER AND STEAM
WATER
A-5 OIL FIRED BOILERS
This boiler is designed for large residences, apartment and commercial buildings. Tested and equipped for 50 lbs. water working pressure.
boiler number
grots
raJt output
Mbh
IbBmR burner capadty
tP
net
ratine Mbit
net rating
eft water
^ Trade Price
For Built-in Water Heaters , Steam and Wate Bailers, see page 28.
approx. shipping
weight
A-504-W(T) A-505-WfT) A-506-W(T)
A-507-W(T) A-508-W(T) A-509-W(T)
A-510-W(T) A-511-W(T)
261 2.55 227.0 1513 * 789.00
346 3.30 300.9 2006
900.00
426 4.00 370.4 2469
1032.00
508 4.75 441.7 2944 588 5.55 511.3 3408 668 6.30 580.9 3872
1103.00 1281.00 1412.00
748 7.00 650.4 4336 830 7.65 721.7 4811
1542.00 1875.00
1518 1770 2025
2282 2539 2794
3050 3298
chimney Ue
8x 12 x 15 8 x 12 x 20 12 x 12x20 12 x 12 x 20 12 x 16x25 12 x 16x25 12 x 16x25 16 x 16x30
STEAM
beiler number
A-504-SfD A-505S(T) A-506-S(T)
A-507-SfO A-508-S(T) A-509-S(T)
A-510-Sm A-511-S(T)
gross IbBbR output
Mbh
261 346 426
508 588 668
748 830
IsBobR burner capacity
CPh
2.55 3.30 4.00
4.75 5.55 6.30
7.00 7.65
nat IsBiift rating
Mbh
oft
staam
195.8 259.6
319.6
816 1082 1332
381.1 441.1 501.1
561.1 622.7
1588 1838 2088
2338 2594
^TTrsde Prtca
8 789.00 906.00 1032.00
1163.00 1288.00 1412.00
1542.00 1875.00
approx. shipping
weight
1519 1771 2027
2284 2541 2796
3052 3300
chimney sUe
8 x12 x15 8 x 12 x 20 12x12x20
12 x 12x20 12x16x25 12 x 16x25
12 x 16x25 16 x 16x30
Suffix "T" denote* boiler with openings in canter sections for tankless heaters.
Standard equipment:
Optional equipment:
Water ASME relief valve Pressure and temperature gauge Drain valve
Cover plate required to clcse unused water heater openings will be furnished only if specified on order for "T" type boiler at added charges as follows:
Trade Price each
..
*4.25
Steam: ASME safety valve Steam gauge Gauge glass with trimmings Drain valve
Zone valve packages are available for water boilers. For details and prices, see page 34.
Oil Burners available on special order.............................................. Price on Application
Orderinf Examples:
1. Boiler only lor steam with standard equipment: 1 A-507 S boiler.
2. Boile' only for water with optional equipment: 1 A 506-W boiler with jacket extension
Jacket extension: Specify on order and add *44.00 to Trade Price of boiler or unit. Jacket extension provides 25' en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbs.
A-5 OPTIONAL EQUIPMENT HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit number
A-504 A-505 A-506 A-507. A-508 A-509. A-510, A-511
"W See page 52
Hast Lld-O-Retor modal No. Inciudad
14A 15A 15AA 16-A 17A
maximum firing rata gallons par hour
2.55 3.30 4.00 5.55 7.65
Page 31
Trada Prtca
*40.00 40.00 50.00 50.00 58.00
approx. shipping weight
158 163 176 180 200
HH-12
01548
Oil FIRED BOILERS WATtl AND steam
dAMtKILMiN STANDARD
HYDRONIC HEATING
A-7 OIL FIRED BOILERS
Ideal for commercial and iiuluaUiai buildings. Available with or less jacket. Tested and equipped Tor SO lbs. water working pressure.
WATER
boiler number
grots ImBmft lBft burner output capacity
Mbfi gph
net l-B-ft rating
Mbh
plains* picS-up factor
net umacketed
ratine 4. ft watar
epprea? Trsdt Price shipping
weight
jacketed
Trade Price
went hipping
waifht
chimney size
A-705-WO A-706-WO A-707-WO
A-70B-WO A-709-WO A-710-WO
A-711-WO A-712-WO
A-713-WO A-714-WO
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
21.45 23.20
753.0 880.0 1040.0
1196.5 1365.2 1530.4
1700.9 1867.8
2034.8 2201.7
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15
1.15 1.15
5020 5866 6933
7978 9101 10202
11339 12452
13565 14678
(1826.00 1092.00 2239.00
2474.00 2601.00 2917.00
3162.00 33444)0
3566.00 3773.00
4186 4787 5445
6029 6669 7330
7956 8616
9278 9944
(10(7.00 2121.00 23(4410
2836.00 2873.00 3118.00
3370.00 3570.00
3819.00 4041.00
4358 16 x 16x28 4963 16 x 16 x 30 5633 16 x 20 x 36
6240 16x20x42 6891 16 x 20 x 45 7569 20 x 20 x 50
8212 20 x 20 x 55 8886 20 x 20 x 60
9568 20 x 24 x 70 10254 20 x 24 x 80
hH-12
STEAM
boiler number
gross IwBbR
lb-Bur>neRr
output capacity
Mbh BP*
net l sslvfl rating
unjacketed
Mbh
sq ft taam
piping 4 pick-up
Trade
Price
factor
approx. shipping weight
Jacketed approx.
Trade Price shipping weight
chimney sue
A-705-SO A-706-SO A-707-SO
A-708-SO A-709-SO A-710-SO
A-711SO A-712-SO
A-713SO A-714-SO
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
21.45 23.20
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
1.333 1.333 1.333
1.321 1.305 1.293
1.288 1.288
1.288 1.288
(1826.001 1892.001 2239.001
2474.001 2001.001 2917.001
3152.00' 3344.00'
3566.00 3773.00
4187 4788 5447
6030 6673 7334
7957 8617
9279 9945
$1937.00 2121.00 2354.00
2630.00 2873.00 3115.00
33704)0 3579.00
3819.00 4041.00
4359 16 x 16x28 4964 16 x 16x30 5635 16 x 20 x 36
6241 16 x 20 x 42 6895 16 x 20 x 45 7573 20 x 20 x 50
8213 20 x 20 x 55 8887 20 x 20 x 60
9569 20 x 24 x 70 10255 20 x 24 x 80
* Th net l = B = R ratings shown art based on piping and pick-up allowancas listed in tha column next to tha ratings. AmericanStandard should bo consulted before selecting a boilar for installations having unusual piping and pick-up requirements.
Standard equipment:
Water ASME relief valve Pressure and temperature gauge
Steam: ASME safety valve Steam gauge Gauge glass with trimmings
Optional Equipment:
Steel pedestal bases for installation under the regularly furnished 12 inch cast iron base for greater base heights are available on order at the fol lowing added charges:
ix1.n liH
bo height
WTroO.
5 thru 7 8 thru 14
8" S 63.00 10" 102.00
If steel pedestal baae is not used, consideration should be given to the use of brick or masonry base as required.
For Additional Optional Equipment, See page 33.
Combustion chombor not furnished. Sou Insfallation-Oporution end Mointononco Manual for combuition chamber? roqrrlroj Sr a-7 bailor?.* 1 2
Ordering Eisnpies: 1. Boiler only with jacket (or steim with optional equipment 1 A-711-S0 boiler jacketed with steel pedestal base 2. Boiler only ur,r;keted for water with standard afliiinnmrt 1 A-/06-W0 limacketed
Note: Be sure to specify on order litter "0" after "S" or "W" or coal fired boiler will be supplied.
Page 32
01549
fSIAMERICAN caSTANDARD
HYDRONIC HEATING
oil burners OPTIONAL EQUIPMENT
A-7 AND FR-A-7 OPTIONAL EQUIPMENT
ELECTRONIC FLAME SAFEGUARD CONTROL EQUIPMENT
ror Factory Mutual Approval requirements, special ,,1'Ctronic flame safeguard controls are available with FA890 Protectorelay, W415A control panel (includes J'TOA base and R488F switching relay),C7013A photocell,
p'laycd oil valve. (2 with 96A-T-7935-R and 96A-T-7937-R.)
Oil burners to meet Massachusetts Code requirements -- Price on application.
boJIMumGr unit
FR-A-706. FR A-707 FR-A-708 FR-A-709 FR-A-710, FR-A-711
bumGf modal
96A-M-7543-L 96A-T-7935 R 96A-T-7937-R 970-8111-R
adtfod TradG Prica charg**
$147.00 49.00 49.00
147.00
NOTE: R41SOA Flame Safeguard contra* on 97A HFLe and 9SA HMj
burners used with FR.A-712. FR-A-713 and FR-A-714 units masts Factory Mutual Approval and Massachusetts coda requirements.
McDonnell & Miller low water cut-off and feeder combinations or low water cut-offs are available for FR-A-7 and A-7 steam units and boilers at added Trade Prices as follows:
unit er boiler no.
MAM no.
AdM Trada Prica
FR-A-706: A-705 thru A-707
FR-A-707 thru FR-A-713 A-708 thru A-714 FR-A-714
47-2
51-2 51-S-2
77.00
100.00 112.00
A-7 and FR-A-7
369 27.00
Provision for special equaliser tapping (1* I.P.S. maximum) for bottom connection of 61-2 or 51-S-2 is located 12 Va inches below water line on front section. Other temperature controls are shown on page 36.
FR-A-7 and A-7 external water heater tappings: two 1' tappings will be furnished on center sections for water boilers only. Lower tapping 23" from bottom of section. Center to center dimension between tappings is 27 H". If desired specify on order and add $12.50 per "C" section to Trade Price of boiler.
DH OIL BURNERS The DH burner is designed and built to exacting standards for dependable and trouble free operation. The quiet motor and reliable controls are regularly furnished for 115 volt, 60 cycle power supply.
tntd*!
wwmbGr
DH-5 DH-6 DH-15 DH-23
(GGGcIfy fGl.
pm hGr
.55 3.00 65 - 3.00 .65 - 3.00 .65 3.00
air hfW 4\mrk. Unftk
GIGWGtiGf
Trod# Wet wfdl GUit
WKlwdGt fattGT |AtG(lGd cad <ofl
wHb GG. 1 Gf GG. J
CGAhGl *Gt GGd pfimorr (OMrol
with pHogget
(GGtnH GGd Mill#
Igm tad call
45
sling
4 8 / pedestal)
4 15 < , r >
4 23 ( flange )
$164.00 164.00 166.00 169.00
_
$145.00 147.00 149.00
*
$111.00 116.00 118.00
ee. *Meweight
ridl cmmI
BG
55 60 64 68
t<r bum*r unit oil bumtr control*
ip'TI
BDH-5
3 packaged unit dh-5
(Primary control, cad cell and )controls, except thermostat, (factory installed. I Draft regulator.
4 3 Boiler unit
DH-5
(Primary control, controls. < Cad cell factory installed. I Draft regulator.
For A-3 units pressure ring is packed with DH-S burner.
*1*11-5 burners for AP(T) packaged units furnished with ''iractory turbulator and are not interchangeable with v,h*r DH-5 models.
`cttiet with strainers for Oh burners used wltn boller-Burner units:
nlid cone 60" with AP(T), solid cone 70' with A-3 packor boiler-burner units.
J ` burners listed in this Price Book are approved by the i- tlonaI Board of Fire Underwriters, comply with U. S. `1H:!!}TTlent Commercial Standard CS-75, and are for use . No i or No. 2 fueloil.
-ktiacmes of oil burners using No. 1 or No. 2 fueloil are for i.,.1"ations at sea level and at elevations up to 1,000 feet. # _)"ce 4% for each additional 1,000 feet above sea level,
-duct from shipping weight of burner with control set:
jess cortrol set
3 lbs.
less control set and primary control
9 lbs.
Disc-turbulator combina tions for DH oil burner are as follows:
firing rata no. fph
R1 .55-1.JO R2 1.00-1.85 1 .65-1.10
2 .90-1.75 3 1.80-2.50 4 2.35-3.00
Selection of nozzle:
firing rata
nozzla pray
.55 to 1.25 60*-70* hollow or solid
above 1.25 60*-70' solid
The correct disc-turbulator combination is furnished in stalled in the DH burner for nozzle size specified on order.
Two-stage fuel unit is available for DH oil burners at added
Trade Price
$6.50
Controls and control sets are shown on page 35.
OfQGfing Examplaa:
1. Oil Burner
1 DH-5 oil burner with No. 5 control Mt *nd 2.SO gph 70 solid nozzlG for A-37M-WBT boiir-bufn*r unit,
t. On' 3ui-n#r
>-'-*3 oil burner with No. 3 control
1.50 gph 60
solid nozzla, with pGdtltal.
s Page 52
Page 33
HH-12
01550
ZONE VALVE PACKAGE
COMFORT COMPUTER
Illustrated is Comfort Computer-Zone
Valve Package
_ AMERICAN STANDARD
HYORONIC HEATING
COMFORT COMPUTER MODEL 370(R)
The American Standard exclusive and unique Comfort Computer is a solid state control which modulates the boiler water temperature in proportion to the number and length of heat demands. This control and zone valve pack age is especially designed for use with American Standard Boilers. Bene fits received are: improved comfort balance in living areas; reduction of wall streaking and expansion noises; and increased operating efficiency.
The Comfort Computer controls the operation of the burner to slow down the response of the boiler temperature to calls for heat by a zone thermo stat. The control optimizes boiler water temperature and will not permit introduction of excessively hot water temperature to a zone. This control permits only those boiler water temperatures actually required by the heating system, yet permits high water temperatures during cold weather or during "pick-up" periods.
The Comfort Computer is designed for Gas Boilers without tankless heaters; and is available in two models, the 370 and the 370R. The model 370 is for use with installed boilers using a solenoid gas valve only; the 370R is for use with all modern gas fired hydronic heating systems.
Trade Prices are as follows: 370 ......................... $42.00
370R
$54.00
COMFORT COMPUTER - ZONE VALVE PACKAGE
The Comfort Computer is available combined with the zone valve package factory mounted and wired. When ordering the complete package the
designation of the zone valve package is added to that of the Comfort Computer,
Trade Prices are: 370R-2Z- $141.00 370R-3Z- $169.00 370R-4Z-$211.00
HYDRONIC ZONE VALVE PACKAGES
No. Z-2 Package for 2 Zorns
No. Z-3 Package for 3 Zonal
No. Z-4 Package for 4 Zonal
1 T822D thermostat
2 T822D thermostats
3 T822D thermostats
2 V8043F zone valves soldered to 3 V8043F %" zone valves soldered to 4 V8043F \" zone valves soldered to
manifold
manifold
manifold
Less transformer
Less transformer
With transformer
Trade Price ........................... $87.00 Trade Price ....... .................. $118.00 Trade Price .............................$187.00
Each zone valve package consists of 2, 3, or 4 Honeywell zone valves soldered to manifold with 114" NPT inlet.
Each zone valve is factory wired to low voltage leads for transformer and all end (auxiliary) switches are wired in parallel with a pre-wired harness. On-the-job wiring re quires 115 volt line to transformer, low voltage connections to circulator control, and low voltage wiii -; to each thermostat.
If H" system piping is used, Sili nominal copper to copper flush bushing can be soldered to any or all of the \ " zone valves on the manifold. Flush bushing not furnished.
One less thermostat is furnished than the number of zone valves per package. An additional thermostat is required when zone valve package is used on boiler furnished less thermostat.
40 VA transformer is not required when control L3l4t(G or R8226B with power for 3 zone valves, is supplied with boiler.
If 40 VA transformer is wanted with No. 2-2 or No. Z-3 Packages, specify on order and add to the above Zone Valve Pack
age prices.
............................................................................................................................. .T Trade Price each $3.30
Honeywell V8043F " Zone Valve sold separately HH-12
Page 34
Trade Price each $23.00
01551
^AMERICAN IS STANDARD
HYDRONIC HEATING
CONTROL SETS, CONTROLS
Centre: Bet
CONTROL SETS FOR BOILER-BURNER UNITS
content* of control set
control
for
numbor
description
add to Trado Prieo of oil burner with bts'e control oot
no. 1 steam
no. 2 steam
boiler without domestic hot water
boiler with year-round domestic hot water, tankless heater
no. 3 gravity water
no. 4 forced water
boiler without domestic hot water, immersion control
boiler without domestic hot water
no. 5
A-3, A-5. FR-A-5 units only with year-round
forced water domestic hot water
T822D PA404A
T822D PA404A L4006A
T822D L4080B
T822D L4081B
T822D L8124C
no. 5-Z forced water
A-3. A-5. FR-A-5 units only. (1 no. 5-Z set is required for each zone in addition to the first zone which is controlled by the no. 5 control set or equivalent.)
T822D R845A
Thermostat Pressuretrol
Thermostat Pressuretrol Aquastat operating control
Thermostat Aquastat limit control
Thermostat Aquastat limit and circulator control
Thermostat Aquastat limit reverse and operating control, circulator relay
Thermostat Relay
$14.90
$11.65 $23.75 $27.75
numbor
description
T822D
TS822A T832A
T852A L4006A L4006E
14081B L40B0D L4080B L6006A
thermostat, adjustable heater 0.18 to 0.8 amp.
thermostat, millivolt thermostat, low voltage, manual turndown
thermostat, electric clock Aquastat operating control
Aquastat operating control: locks out on high limit setting; manual reset
Aquastat limit and circulator control Aouastat limit control Aquastat limit control Aquastat operating and circulator
L8124C L8124B L8124E
L404C L604A L8148E L8148G
Aquastat limit, reverse and operating control, circulator relay
line voltage burner control, horizontal case for pas or oil
millivolt burner circuit for gas with manual-auto switch, vertical case
low voltage burner circuit for gas. vertical case. Power for 2 zone valves
Aquastat-relay combination, high limit and line voltage circulator control. horizontal case:
Pressuretrol w/man. reset
SPDT operating controller
low voltage burner control for gas. Power for 2 zone valves.
millivolt burner control for gas. Power for 3 zone valves.
CONTROLS
Met
$ 7.25 7.25
26.80
42.50 14.90 17.10
number
PA404A RA89A RA832A R845A R8226B R8182D
22.15 ii.as 11.25
R8182E
15.80
R8182F
34.25 31.15 33.70
R8184G
29.90 25.90
23.70
120320
description
Tredo Price
Pressuretrol
relay, SPST relay, DPST relay, DPST
Transformer and circulator relay
Aquastat-relay combination, high and low limit; providing room thermostat control of circulator: light sensing primary
control, less cad cell; safety switch timing 70 seconds. For use with tankless.
Aquastat combination, high limit;
providing room thermostat control of circulator: light sensing primary control, less cad cell: safety switch timing 70 seconds. For use less tankless.
Aquastat combination, high limit:
providing room thermostat control of burner and boiler water temperature control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless.
light sensing primary control, less cad cell:
control numbor
safety switch timing-seconds gph
R8184G1005
60
R8184G1021
30
R8184G1013
15
cadmium sulfide cell only
3 3-7 7-20
$17.10 16.25 20.50 20.50 11.25
57.25
53.00
47.25
31.80 34.90 39.00
2.30
23.70
*To substitute T852A for T822D Thermostat; specify on order control set with
suffix "B" and .odd to trade p>".ce different1;
above.
See page 52
AccMlcnes ina uorrrol, i^iucec in this price Book ere lor use m conjunction with Americen-Slenflerp proCgcts.
Page 35
HH-12
01552
STOKER FIRED BOILERS WATU AND STEAM
d AMERICAN STANDARD
HYORONIC HEATING
A-7 STOKER FIRED BOILERS
The i-.-r.dnrd for commercial and industrial building .priicauun. A vaiiabie with or less jacket. Tested and equipped for 50 lbs. water working pressure.
WATER
bailor number
A-705-WC A-706-WC A-707-WC A-708-WC A-709-WC A-710-WC A-711-WC A-712-WC A-713-WC A-714-WC
iron IbIkR output
Mbh
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
I.BbR burner capacity tbs./hr.
95 111 131
151 172 194
215 236
257 278
A not lBR ratine
Mbh
753.0 880.0 1040.0
1196.5 1365.2 1530.4
1700.9 1867.8
2034.8 2201.7
piping 4 pick*up factor
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15
1.15 1.15
not rating sq. ft water
5020 5866 6933
7978 9101 10202
11339 12452
13565 14678
unlaefcotsd
Trad# Price
appro*. shipping weight
4
n
lackatad appro*. shipping weight
chimney siza
*1826.00 1092.00 2239.00
2474.00 2691.00 2917.00
3152.00 3344.00
3566.00 3770.00
4120 4775 5436
6017 6693 7370
7972 8610
9323 10013
SI 937.00 2121.00 2304.00
2638.00 2073.00 3115.00
3370.00 3579.00
3019.00 4041.00
4292 4950 5619
6226 6908 7589
8233 8908
9593 10283
16 x 16 x 28 16 x 16 x 30 16 x 20 x 36
16x20x42 16 x 20 x 45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
20 x 24 x 70 20 x 24 x 80
STEAM
boiler number
A-705-SC A-706-SC A-707SC A-708-SC A-709-SC A-710-SC A-711-SC A-712-SC A-713-SC A-714-SC
grotl l=BsR output
Mbh
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
IsBsR burner capacity Ibt./hr.
95 111 131
151 172 194
215 236
257 278
net IsBsR rat "C
A
Mbh
sstqe.afmt.
piping 4 pick-up
factor
unjacketed
Jacketed
Trade Price
approx. shipping weight
Trade Price
appro*. shipping weight
chimney sUs
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
1.333 1.333 1.333
1.321 1.305 1.293
1.288 1.288
1.288 1.288
$1020.00 1992.00 2239.00
2474.00 2691.00 2917.00
3152.00 3344.00
3560.00 3770.00
4121 4776 5438
6018 6697 7374
7973 8611
9324 10014
$1937.00 2121.00 2304.00
2630.00 2073.00 3115.00
3370.00 3570.00
3019.00 4041.00
4293 4951 5621
6227 6912 7593
8234 8909
9594 10284
16 x 16x28 16 x 16x30 16 x 20 x 36
16 x 20 x 42 16 x 20 x 45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
20 x 24 x 70 20 x 24 x 80
* The net l = S=rR ratings ihawn ore based on piping and pick-up allowances listed in the column next to the ratings. Americon-Standard should be consulted before selecting o boiler for installations having unusual piping and pick-up requirements.
Standard equipment: Water: ASME relief valve Pressure and temperature gauge
Steam: ASME safety valve Steam gauge Gauge glass with trimmings
Optional equipment: Steel pedestal bases for installation under the regularly furnished 12 inch cast iron base for greater base heights are available on order at the following added charges:
action sico
5 thru 7 8 thru 14
basa height
8" 10"
"W Trade Price
$ 63.00 102.00
If steel pedestal base is not used, consideration should be given to the use of brick or masonry base as required. For additional optional equipment see page 33.
Ordering CsompU: Slokr boiler for woior with jocket with optional equipment: 1 A-70B-WC |Ock*td boii*r, with stool pedestal boso.
HH*1 2
Page 36
01553
FamI AMtKIt-AIN
LSJ STANDARD
HYDRONIC HEATING
A-7 HAND FIRED BOILERS
Jacketed and unjacketed Tested and equipped for 50 lbs. water working pressure
HAND FIRED BOILERS
WATER AND STEAM
WATER
Mlr
numMr
A-705-W A-706-W A-707-W A-708-W A-709-W A-710W A-711-W A-712-W
lgfBOSSR
output Mbh
1122 1298 1510
1708 1910 2108
2288 2456
not tmBmH rating
Mbh
625.4 744.3 894.0
1042.1 1202.0 1363.5
1518.2 1667.3
A piping 4 picknip
factor
1.794 1.744 1.689
1.639 1.589 1.546
1.507 1.473
not rating op. ft wrator
4169 4962 5960
6947 8013 9090
10122 11115
unfackotod
Trad* Price
IPP1 chipping
wight
(2011.00
2108.00 2434.00
2005.00 2872.00 3009.00
3304.00 3477.00
4546 5270 6025
6679 7508 8170
8848 9565
Jacket**
Trad* Mea
approx. chipping wight
(2122.00
2310.00 25003)0
2049.00 305340 32894)0
3521.00 37114)0
4718 5545 6208
6888 7643 8389
9109 9863
chimney tlx*
16 X 16x40 16x20x45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60 20 x 24 x 65
20 x 24 x 70 24 x 24 x 75
STEAM
b*ll*r number
A-705-S A-706-S A-707-S A-708-S A-709-S A-710-S A-711-S A-712-S
grot* IsBbR output
Mbh
1122 1298 1510
1708 1910 2108
2288 2456
Mbh
net IbBbR
ap. ft
steam
A
piping 4 pick-up factor
625.4 744.3 894.0
1042.1 1202.0 1363.5
1518.2 1667.3
2606 3101 3725
4342 5008 5681
6326 6947
1.794 1.744 1.689
1.639 1.589 1.546
1.507 1.473
unfackotod
Trade Rrica
approx. shipping
wight
$2011.00 2185.00 2434.00
2005.00 2872.00 3009.00
3304.00 3477.00
.
4561 5285 6036
6692 7521 8183
8861 9582
Jacketed
Trade Price
approx. chipping
weight
(2122.00 2316.00 2500.00
2149.00 3053.00 3260.00
3521.00 3711.00
4733 5460 6219
6901 7656 8402
9122 9880
chimney size
16 x 16x40 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 65 20 x 24 x 70 24 x 24 x 75
* The net l=B=R ratines shown are based on piping and pick-up allowances listed in the column nest to the ratings. American Standard should be consulted before selecting e boiler for installations having unusual piping and pick up requirements.
Standard equipment:
Water ASME relief valve Pressure and temperature gauge Automatic damper regulator Firing tools
Steam: ASME safety valve Steam gauge Gauge glass with trimmings Automatic damper regulator Firing tools
Ordering Example:
Hand fired boiler for water with jacket with standard equipment: 1 A-706-W jacketed boiler
See page 52
Page 37
`-12
01554
HYDRONIC ASSEMBLING TOOLS
fSl AMERICAN
taSTANDARD HYDRONIC HEATING
PACKAGED HYDRAULIC ASSEMBLING TOOL: All necessary parts to assemble any American-Standard sectional boiler, except Ion? tie rods, are shipped in one packing case; the long tie rods are furnished in their own wooden box. Total weight approximately 250 lbs.
~W Trade Price - $400.00
RAOIANTRIM ASSEMBLY CLAMP: This tool is designed to draw Radiantrim cast iron baseboard sub-assembled panels or sections together with ease as per instructions included. Order through your American-Standard distributor.
W Trade Price each - $10.75
HEATRIM COPPER TUBE BENDING TOOL: This tool is specifically designed to bend riser tube connections for Model R Heatrim baseboard panels. Eliminates costly copper fittings. Com plete instructions for tool use included.
Trade Price each -- $14.55
HEATRIM RISER HOLE TEMPLATE: This tool accurately and quickly lo cates riser hole locations for Model R Heatrim panels. Consists of template (two pieces I. 8 ft. steel tape and com plete instructions.
yr Trade Price each -- $2.90
ALUMINUM NIPPLE-SETTING-HAMMER: --consists of a 2 lb. 2'/i" diameter aluminum head and a 14" long hard wood handle. The aluminum head will not damage the nipple edges and per mits the heavy blows necessary to set nipples to the recommended depth quickly.
Trade Price each -- $4.75
SECTION BUMPING BLOCK: -- made of a 6" x 6" x 18" hardwood block with a convenient steel handle for swinging the tool. Its purpose is to bump a sec tion onto the pre-set nipples of the previous section to the recommended depth, prior to pulling the section up, with one or two blows without damage to the section.
Trade Price each - $14.00
HH-12 yr See cage 52
Page 38
01555
/^AMERICAN
ba STANDARD
HYDRONIC HEATING
ELECTRA II PACKAGED ElECTRO-HYDRONIC BOILERS
Completely packaged with deluxe two-toned brown and beige jacket. Pre-wired for 240 volt, three wire, 60 cycle, single phase service. Designed and equipped with CCnfTols for forced circulation. Tested and equipped for 30 lbs. water working pressure.
PACKAGED BOILERS
electric
WATER
ctccTsic cnrstt
ioiics
*itk istksu uhiT coereoi
E38074________ NO 0000000
WATER ONLY pockeged unit number
EP-7 EP-10 EP-14 EP-17 EP-20
output watts
2,000 3.000 4,000 5.000 6.000
output btuh
6.826 10.236 13,648 17,060 20,472
amps 9 240 volts
8.34 12.50 16.65 20.81 25.00
W Trade Price wMi
standard equipment
$21240 212.00
212.00 212.00 212.00
approx. shipping
weight
49 49 49 49 49
Ordennf Example
IP Pockoged Boiler with itandord equipment:
1 EP-14 boiler
See page 52
Standard equipment
T822D thermostat Circulator with piping Drain valve ASME relief valve Pressure and temperature gauge Expansion tank (diaphragm type) L4080D immersion limit control J- W. Hobbs M4440 low pressure switch Automatic air vent a Output ratings based on 240 volts. Reduce output ratings for other
voltages as follows: 230 volts, 8%; 220 volts, 16%; 208 volts, 25%.
All electrical controls, circulator, expansion tank, pressure and tempera ture gauge, automatic air vent, and drain valve, are factory installed and wired. Thermostat and relief valve shipped in accessory bag fastened inside boiler carton.
Zone valve packages are available for water boilers. For details and prices, see page 34.
Page 39
01556
HH-12
PACKAGED BOILERS
ELECTRIC WATER
. -- ! AMERICAN kza STANDARD
HTDRONIC HEATING
"ELECTRA"
EP PACKAGED tLtCIRO-HYDRONIC BOILER
For the ultimate in modem electric heating, choose the "Electra." a completely assembled, pre-wired, hydronic heating east iron boiler.
Designed for ultra-safe operation and equipped with controls for forced circulation. Attractive two-toned brown and beige jacket completely conceals all componenta including
the circulating pump and expansion tank. Rugged boiler shell is tested and equipped for 30 lbs. water working pressure and unit is ar
ranged for 2*0 volt, three wire, 60 cycle, single phase service.
WATER
pacupi Mriar
awnBtr tf
tenants
BtftRVt watts
Mrttvt
strj.
Stull
EP-34 EP-51 EP-68 EP-82
2 3 4 5
10,000 15.000 20.000 24.000
34,130 51.195 68.260 81.912
41.7 62.4 83.2 100.0
ELECTRIC CENTRAL HEATING SOUR mm wnetAt unit carnm.
. 38076_ _ _ _ _ _ _ _ No. ooo ooo ,
Tri ft** vttn
staniartf naifmt
8428.00 440.00 4583)0 474.00
Msni. tfcteatnt waiftt
98 99 100 102
Standard equipment
T822D thermostat
AT72D low voltage transformer RSIS* sequencing control L4008J adjustable immersion type limit control Allen-Bradley 836CP11-HKAZS High pressure switch with EP-68 and
EP-82 only J. W. Hobbs M*4*0 Low pressure switch 1 Li' circulator Expansion tank (diaphragm type) Automatic air vent ASME Relief valve Pressure and temperature gauge Drain valve
OrSering frimplr EP Packaged Boiler with standard equipment: 1 EP-68 boiler
HH-12 See :a;e 52
Not*; EP Electric Boilers are shipped with jacket and all controls (except thermostat and relief valve) factory installed and wired. Circulator and expan sion tank are factory installed and enclosed in the jacket. Thermostat, relief valve and nipple, and circulator flange and gasket shipped in accessory bag fastened inside boiler carton.
Output ratings based on 240 volts. Reduce output ratings for other voltages as follows: 230 volts, 8%; 220 volts, 16%; 208 volts, 25%.
Optional equipment
Sequencer Package: Available for field installation on EP-68 and EP-82 Boilers in addition to regularly furnished sequencing relay. Package contains all necessary equipment and instructions for the installation of one (EP-68) or two (EP-82) 24A11-4 Sequencer(s) which will provide a 45 second current delay between the third and fourth elements of the EP-68 or between the third, fourth and fifth elements of the EP-82. Standard R8154 relay provides a 1 /120th of a second (L4 cycle) current delay between each element.
innninhcup
NyinMMn
EP-68 EP-82
312.24 23.60
Nt: Zone valve packages are available for water boilers. For details and prices, see page 34.
Page 40
01557
fWIAMtKILAN ISiSTANDARD
HYDRONIC HEATING
HEATRIAA PANELS
MODEL R HEATRIM PANELS
SEE CURRENT^L'TCRATURe FOR APPROVED i=d=R HOT WATER RATINGS " (For Yt" Model ft-750 and Vi~ Model R-500 Panels)
DESCRIPTION
numfrf
jMckj(*d Pf
MODEL R-750-A COMPLETE ASSEMBLED UNITS (Single Pack)
includes 1 each of front and oack panel, element, damper, necessary support brackets, slide cradles and 1 se joining pieces. Finished with white prime paint All factory assembled.
Bos Color Coded-Rad
Drdtriif Example
1-Doi R-750-A4
R-750-A2 R-750-A3 R-750-A4 R-750-A5 R-750-A6 R-750-A7 R-750A8
per lineal foot
2 ft. length 3 ft. length 4 ft. length 5 ft length 6 ft. length 7 ft. length 8 ft. length
Tr*d Prtcm
pprox. Mpptnf w*ctrt
S 2.09
4.18 6.27 8.36 10.45 12.54 14.63 16.72
5 7 9 12 13 16 18
MOOEL R-500-A COMPLETE ASSEMBLED UNITS (Single Pack)
includes 1 each of front and back panel, Vi" element damper, necessary support brackets, slide cradles and 1 se joining pieces. Finished with white prime paint. All factory assembled.
Bos Color Coded--Green
Ordering Eiimpli:
1--box R-500-A3
R-500-A2 R-500-A3 R-500-A4 R-500-A5 R-500-A6 R-500-A7 R-500-A8
per lineal foot
2 ft. length 3 ft length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
1.98
3.97 5.95 7.9* 9.92 11.91 13.89 15.88
5 7 9 11 14 15 18
MODEL R ENCLOSURE ONLYASSEMBLED (Single Pack)
includes 1 each of front and back panel, damper, necessary support brackets, slide cradles and 1 set joining pieces. Finished with white prime paint All factory assembled.
8ox Color Coded--Black
Ordering Example:
1-box R-3-A
R-3-A R-4-A R-5-A R-6-A R-7-A R-8-A R-10-A R-12-A
MOOEL R ENCLOSURES ONLYUNASSEMBLED (Bulk Pack)
includes 3 sets of front and back panels, dampers with clips, necessary support brackets, slide cradles and 2 sets of joining pieces. Finished with white prime paint. Unassembled.
Box Color Coded-Blue
Oreermg Example:
1-box R-5-B
R-3-B R-4-B R-5-B R-6-B R-7-B R8B R-10-B R-12B
per lineal foot
3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 10 ft. length 12 ft. length
1.02
3.06 4.07 5.09 6.11 7.13 8.15 10.19 12.22
per lineal foot
three 3' lengths thre.: 4' lengths three 5' lengths three 6' lengths three 7' lengths three 8' lengths three 10' lengths three 12' lengths
.91
8.22 10.96 13.70 16.44 19.18 21.92 27.41 32.89
6 8 10 11 13 15 17 19
16 21 26 30 35 40 48 58
For comparative and estimating purposes only.
w See page 52
Page 41
HH-12
01558
HEATRIM ELEMENTS AND ACCESSORIES
^AMERICAN LsiSTANDARD
HVDRONIC HEATING
------ MODEL R HEATRIM ELEMENTS AND ACCESSORIES
Plffilllliiii,]
DESCRIPTION
E-750 (%" tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths. Ordering Esimplt.-
1-bundle E-750-3
ordering number
E-750-3 E-750-4 E-750-5 E-750-6 E-750-7 E-750-8
packaged per
per lineal foot
Trade Price
$ 1.12
approx. shipping
weight
six 3' lengths six 4' lengths six 5' lengths six 6' lengths six 7' lengths six 8" lengths
20.22 26.96 33.71 40.45 47.19 53.93
9 12 16 18 22 25
E-500 <V4" tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths.
Ordering Eiimplt: 1-bundle -500-4
E-500-3 E-500-4 E-500-5 E-500-6 E-500-7 E-500-8
*per lineal foot S 1.02
six 3' lengths six 4' lengths six 5' lengths six 6' lengths six 7' lengths six 8' lengths
18.33 24.44 30.56 36.67 42.78 48.89
8 10 12 16 19 21
r?'.
ACCESSORIES
End Cap-3" wide-Right Hand End Cap-3" wtde-Left Hand Valve Enclosure--4" wide--Right Hand Valve Enclosure-4" wide--Left Hand Valve Enclosure-6" wide-Right Hand Valve Enciosure-6" wide--Left Hand Inside Corner-hinged front and top-90* Inside Corner-back piece-90* Inside Corner-one-piece front and top--135*/45* Inside Corner-back piece-135*/45* Outside Comer-90* Outside Corner-13S*/45* Filler piece set-7" wide Filler piece set-14" wide Wall End Piece-3" wide Return tubing wire hangers Connecting tubing wire hangers Joining piece set-2" wide Extra support brackets with slide cradles and damper
clips Tube bending tool
NOTE: Finished with white prune paint.
RA-ECR-03 RA-ECL-03 RA-VER-04 RA-VEL-04 RA-VER-06 RA-VEL-06 RA-ICF-90 RA-ICB-90 RA-ICF-45 RA-ICB-45 RA-OCF-90 RA-OCF-45 RA-FPS-07 RA-FPS-14 RA-WEP-03 RA-WHR-50 RA-WHS-50 RA-J PS-02
box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 10 box of 5 box of 10 bag of 50 bag of 50 box of 20 sets
RA-SBP-20 box of 20 sets
For comparative and estimating purposes only.
NOTE: Add 25'. :o price when ordering in less than quantities indicated above.
8.40 8.40 11.55 11.55 17.64 17.64 10.50 3.36 10.50 3.20 12.60 14.70 8.50 6.SO 4.41 2.10 2.21 5.46
7.40 14.55
4 4 9 9 10 10 3 4 2 2 5 3 9 9 4 -- -- 5
5
HH-1 2 See sace 52
Page 42
01559
l5J STANDARD
HYDRONIC HCATIN6
HEATRIM PANELS
MODEL SS HEATRIM PANELS, ELEMENTS AND ACCESSORIES Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools and churches.
The SS Heatrim is ideal for residential "hard to heat" areas such as bathrooms, hallways, etc.
SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For t " Modal S575 and 1" Model S3-1 CO Panels)
DESCRIPTION
nmo7
package* per
Pries
MODEL SS-75
COMPLETE UNITS
(Dual Pack)
Box includes 2 each of front and back panel, % " element, damper, necessary support brackets and slide cradles and 1 joining piece set. Finished with off - white prime paint.
Ordering Example: 1-txu SS-75-4
SS-75-2 SS-75-3 SS-75-4 SS-7S-5 SS-75-6 SS-75-7 SS-75-8
MODEL SS-100
COMPLETE UNITS
(Dual Pack)
Box includes 2 each of front and back panel, 1' element, damper, necessary support brackets and slide cradles and 1 joining piece set. Finished with off - white prime paint.
Ordering Example: l-box SS-100-3
SS-100-2 SS-100-3 SS-10&4 SS-100-5
SS-100-6 SS-100-7 SS-100-8
'per lineal foot S 3.20
Two 2 ft. lengths Two 3 ft. length! Two 4 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths
812.80 19.20 25.60 32.00 38.40 44.80 51.20
pet lineal foot S 3.55
Two 2 ft. lengths Two 3 ft. lengths
Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths
14.20 21.30 28.40 35.50 42.60 49.70 56.80
pprai. aMpplirg veifM
14 20 26 33 39 46 52
14 20 26 33 39 46 52
MODEL SSI-75 COMPLETE UNITS
(Single Pack)
Box includes 1 each of front and back panel, % " element, damper, joining piece set and necessary support brackets and slide cradles. Finished with off-white prime paint.
Ordering Example: I-box SSI-75-7
SSI-76-2 SSI-75-3 SSI-75-4
SSI-75-6 SSI-75-6 SSI-75-7 SSI-75-8
*per lineal foot S 3.35
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
6.70 10.05 13.40 16.75 20.10 23.45 26.80
7 11 14
18 21 25 28
MODEL SSI-100
COMPLETE UNITS
(Single Pack)
Box includes 1 each of front and back panel, 1' element, damper, joining piece set and necessary support brackets and slide cradles. Finished with off-white prime paint.
Ordering Example: 1-box SSI <100-4
SSI-100-2 SS1-10O-3 SSI-100-4 SS1-10O-5 SSI-100-6
SSI-100-7 SSI-100-8
*
V
*por eomoA'ttiv# and estimjtmg purposes only.
See page 52
Page 43
*per lineal foot S 3.70
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
.
7.40
11.10 14.80 iaso 22.20 25.90 29.60
7 11 14 18 21 25 28
HH-12
P*Sl 01560
HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES
^AMERICAN
Si STANDARD
HYDRONIC HEATING
MODEL SS HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES
Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools and churches. The SS Heatrim is ideal for residential "hard to heat" areas such as bathrooms, hallways, etc.
DESCRIPTION
:?
packaged per
Trad* Trie*
MODEL SS
ENCLOSURES ONLY (Bulk Pock) Box includes 4 each of front and back panel, damper, necessary support brackets, connecting' tube wire hangers and 3 joining piece sets. Finished with off white prime paint. Ordering Example:
1-box $$4
MODEL SSI
ENCLOSURES ONLY
(Single Pack) Box includes 1 each of front and back panel, damper, joining piece set, necessary support Brackets and connecting tube wire hangers. Finished with off white prime paint. Ordering Example:
1--box ttt-4
ES-75-8 (% " tube)
ELEMENTS ONLY (Buik Pack) Box includes eight 8 foot lengths of y*" element and necessary slide cradles. Ordering Example:
1-box ES-7J.I
ES-100-8 (1" tube)
ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of X" element and necessary slide cradles. Ordering ExnmpJe:
1-box ES-100-1
SS-3 SS-4 SS-5 SS-6 SS-7 SS-8
SSI-3
ssi-a
SSI-5 SSI-6 SSI-7 SSI -8
ES-75-8
ES-100-8
par linaal foot S1.6S
Four 3 ft. lengths Four 4 ft. lengths Four 5 ft. lengths Four 8 ft. lengths
Four 7 ft. lengths Four 8 ft. lengths
$19.80
26.40 33.00 39.60 46.20 52.80
`per lineal foot S1.8S
3 ft. length 4 ft. length
5 ft. length 6 ft. length 7 ft. length 8 ft. length
S 5.55 7.40 9.25
11.10 12.95 14.80
per lined foot S1.S5
Eight 8 ft. lengths $99.20
per lineel foot SI.90 Eight 8 ft. lengths $121.60
ACCESSORIES
R. H. %Vt" End Covers (Short of Floor) ................................................ .. L. H. 2V4" End Covers (Short of Floor) ........... --..........................-.... .. R. H. 2%" End Covers (Extend to Floor) .............................................. . L. H. 2H" End Covers (Extend to Floor) .... -........................................ R. H. 6" End Covers (Short of Floor) ........... ......................................... . L. H. 6" End Covers (Short of Floor) ...................................................... . R. H. 6" End Covers (Extend to Floor) .................................................. _ L. H. 6" End Covers (Extend to Floor) .................................................. .. Inside Corner Covers ............................................................................... .. R. H. Valve Enclosures with hinged access door................................... .. L. H. Valve Enclosures with hinged access door................................... .. R. H. Valve Enclosures with hinged access door & knockout for
mainless installation ............................................................................... .. L. H. Valve Enclosures with hinged access door & knockout for
mainless installation ............................................................................... .. Wall End Pieces (Short of Floor) .......................................................... .. Wall End Pieces (Extend to Floor) ......................................................... .. Outside Corner Covers .............................................................................. .. 14" Filler Pieces ...................................................................................... .. 2* Joining Piece Sets ............................................................................... .. Support Brackets. Slide Cradles, Damper Clips .................................. .. Return Pipe Hangers ............................................................................... .. Damper Joiners ................................................................................... .. Connecting Tube Hangers ...................................................................... .
SS-ECR-25S SS-ECL-25S SS-ECR-25F SS-ECL-25F SS-ECR-06S SS-ECL-06S SS-ECR-06F SS-ECL-Q6F SS-IC-90 SS-VER-06H SS-VEL-06H
SS-VERK-06H
SS-VELK-06H SS-WE P-255 SS-WE P-25r SS-OC-90 SS-FPS-14 SS-J PS-02 . SS-S8P-24 SS-WHR-50 SS-DJ-50 SS-WHS-DO
Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12
Box of 12
Box of 12 Box of 12 Box of 12 Bex of 4 Box of 6
of 24 8ox of 24 Box of 50 Box of 50 Box of 50
$11.55 11.55 14.70 14.70 15.75 15.75 17.85 17.85 7.35 31.50 31.50
32.00
32.00 4.75 5.25 12.60 12:60 5.30 10.50 5.25 3.95 6.30
ppre** Mp*#f w**fM
31 42 52 63 73 84
11 14 18 22 25 29
42
48
8 8 9 9 7 7 7 7 s 13 13 13 13 4 4 5 14 4 to 1 1
`or eomporo`i<r 0"d ifimo'ifig purpOfCl only
4r- Add 25* to pne*
ordering m lu than quontih*i indi<of#d obov*
H-12 r See cage 52
Page 44
01561
r*l AMERICAN ca STANDARD
HYORONIC HEATING
RADIANTRIM BASEBOARD PANELS
SEE CURRENT LITERATURE FOR APPROVED l=B=R STEAM AND HOT WATER RATINGS
BASEBOARD PANELS RADIATORS
RADIATOR ACCESSORIES
ARCO RADIATORS
width
6 tube 4, 6 tube
4 tube
height. Inch** sq ft per lection ^Trado Price p*r sq ft
32 3.7 25 2.0. 3.0 19 1.6
$2.69 2.11 2.24
par lineal foot
Tr*de Price-- $6.04
par s^uars foot
$1.77
Model 10 Radiantrim Panel lengths <2V4 ft to 30 ft) are made up from the following sections:
1 Vk ft Left hand end section
1 ft Right hand end section
2 ft Left hand end section
2 ft Right hand end section
2 ft Center section
Assembly length with legs and tappings at each end:
1Vk ft Double end section
2 ft Double end section
For purpose of estimating shipping weights, use 4 Vi pounds per sq. ft. 26.15 pounds per lineal foot.
Model 10 Accessories
^ Price
Arco Radiators are regularly furnished with two and onehalf inch (2Vk") legs. Available on Special Order with four and one-half inch (4V4') legs, or without legs--Price on application. Arco Radiators sold only in even number of sections up to a maximum of 56 sections.
For purpose of estimating shipping weights, use 4 Vi pounds per sq. ft.
Ordtrisg Eustgle: 1-12 Section 25' Arco 4 Tube Vi i Vi
SUNRAD RADIATORS
Extension Panel with 3 Brackets
Two 6 ft lengths per box........................................ $19.85
Extension Panel Retaining Bracket......................
AS
Extension Panel Cover Strip ................................
A1
Assembly Clamp.................................................... 10.75
Short-Compression Corner Connection...............
3.20
Long-Compression Corner Connection ............... <.31
Retaining Block ....................................................
.24
Adjustable Leg ......................................................
.34
Tie Bolt ............................................................................. 12
These itsms ara regularly furmshad as raquirsd with Mods! 10 Rt< diantrim Panels and Accessories. Pncas ara shown for rapair or re placement purposas.
Packed in quantity of 10 per box (Avaiiab/e only m this minimum quantity) perboioflO
Inside Corner Cover .............................................. Extended Inside Corner Cover ............................... Outside Corner Cover............................................... Valve Enclosure (all R.H. or L.H.) ......................... End Box (all R H. or L.H.) ..................................... 10" Plain Extension Piece .........................................
Extension End Piece (all R.H. or L.H.) ....................
$19.71 35.73 36.49 37.10 14.76 17.23
10.60
Ordering Example
1-7 ft. Model 10 Radiantrim Panel. 1-Box of Model 10 Right Hand Valve Enclosures.
Important: Incraas. lit. 5% for re cited installation--Vt" air tpoca tap and sidos, Zi" at back. Incroasa tiz.
13% for rightly racassad installationno claaranco top at sidos, Zi ' air spaca at back.
type M 5 x 20
tq ft par section
2.25
Trad* Price par *q ft
$2.59
Sunrad Radiators are regularly furnished with legs and twopipe inside connections. Available on special order with onepipe connections, outside tappings or without legs--Price on application.
Sunrad Radiators sold in even number of sections from 4 to 30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections.
Sunrad Grilles
Inlet--Stamped Lattice Type.........................per section 50.33 Special No. 16 Gauge with Lecking Device................................
Price cn application
For purposes of estimating shipping weights, use 8 pounds per sq ft
Ordering Examplt: 1-10 Section M5 > 20 Sunred T-4 Vi x W 1-Typt M Sunrad Grille for above.
EXTRA RADIANTRIM ACCESSORY BAGS
Bag No.
For
Trad* Price
0 Double Leg Section I 2>k'-6' Panel Length 2 8Vi'-12' Panel Length 3 12W-18' Panel Length 4 18Vk'-24' Panel Length 5 24 Vi '-30' Panel Length
51.06 1.33 2.85 4.23 5.57 7.16
Sufficient quantities of these bags are regularly furnished with Radiantrim Panels. Prices shown are for extra bags as may be required.
RADIATOR ACCESSORIES
Trad* Pnce #*ch
Arco Brackets:
For 4 and 6 tub*, with Wall Plate......................................... $1.36
Arco Raciatcr Pedestals:
end S'*.......................................................................................
.53
i V ....................................................................................... 66
Oil.*. O' SCKCtS.................................................................................... 1.03
Nicoie*. Dlugs. Bushings, etc.:
V, r\ IV, IV Plugs, Bushings ......................................
V. 1". IV Slip Nipples.................................................
.36 .36
1/8" Air Vent Plugs.....................................................................
.02
Radiator Rod Nuts.................................................................. i'.p -iator Rods .................................................... per section
.01 ,01
Aoove items jvjiijdi* for us* only with our Radiator products.
See page 52
Page 45
HH-12
01562
9
CONVECTORS
r51 AMERICAN bd STANDARD
HYDRONIC HEATING
MULTIFIN CONVECTORS TTPE K - STOCK MODEL - FREE STANDING Expanded prices For use on two-pipe steam and hot water systems only.
CGtHWf
No. 4 depth (4Vi* cabinet)
Mrt M.
** VtPVt
IfflN.
llHMMIt ti|k(
Frit*
20' cabinet height
No. 6 depth (6Vi' cabinet) No. 8 depth (8Vi' cabinet) No. 10 depth (10Vi* cabinet)
nil M.
hN
Wfft
ifeiMKI iM
Frit*
Miff Me
n*
wlWl
(ffffNI. Tf*4*
tifbff
Frit*
Miff M.
** # Mf*Vt
tfffM.
ifcep*i*f Tr*d*
vti|N
Frit*
20 420-20 24 424--20
10.6 13.0
IB $24.04 620-20 14.9 21 526.65
20
25.52 624-20 18.4 24
28.12
.... ....
2$ 62S-20 22 0 27
32
632-20 23.5 29
33.22 832-20 31.7 33 537.02
36
636-20 29.0 33
55.37 836-20 36.0 37
30.ee 1036-20 45.5 42
40
640-20 32.5 34
37-51 840-20 40.4 39
42.35 1040-20 51.2 48
44
644-20 36.1 37
39.71
4$
646-20 39.6 40
41.91 648-20 49.2 46
47.10 1046-20 62.3 52
56
656-20 46.7 45
46.28 856-20 58.0 51
53.24 1056-20 73.4 58
64
664-20 53.8 52
so.se 864-20 66.9 59
55.ee 1064-20 84.5 64
24' cabinet height
545.54 49.01
55.88 82.70 60.52
20 420-24 24 424-24 28 428-24 32 36 40 44 48 56 64
12.1 20 524.97 620-24 17.2 23 525.11
14.9 22
26.68 624-24 21.2 26
30.53
17.8 25
28.44 628-24 25.4 30
632-24 29.5 636-24 33.5 640-24 37.6
33 35 38
35.70 38.12 40.85
832-24 836-24 840-24
35.6 40.5 45.5
38 40 44
539.44 42.48 45.54
1036-24 1040-24
490 55-2
45 52
644-24 41.7 648-24 45.7 656-24 53.9 664-24 62.2
42 44 50 57
43.18 45.65 50.71 55.83
848-24 858-24 864-24
55.4 65.2 75.3
50 55 63
sue 57.64 eue
1048-24 1056-24 1064-24
67.1 79.0 91.0
62 64 71
$47.69 51.48
58.85 66.17 73.54
32' cebinet height
....20 620-32 IB.7 29 625.99
24
624-32 23.1 32
31.74
--28
628-32 27.7 36
34.54
32
632-32 32.1 40
37.29 832-32 40.9 45 142.68
36
636-32 36.5 43
39.99 836-32 46.5 48
48.15 1036-32 S5.0
54
40
640-32 41.0 48
42.74 840-32 52.2 56
4907 1040-32 61.9
59
44
644-32 45.4 56
45.43
48
648-32 49.8 58
48.16 848-32 63.6 65
55.65 1048-32 75.3
69
56
656-12 33.7 37
53.63 856-32 74.9 73
5304 1056-32 86.7
76
64
664-32 |7.3 -.71
59.24 564-32 86.5 76
70.79 1064-32 102.2 84
Plugs and bushings are not regularly furnished with Multifln Convectors, but are available for separate sale at prices shown on page 45.
Note: For stock model cabinet extras, see page 50. Ordering Eiimpli:
l-K-636-32 Multifin.
$51.37 S5.61
63.86 72.11 40.47
HH-12 ^ See cage 52
Page 46
, -- ^AMERICAN 15* STANDARD
HYDRONIC MATING
CONVECTORS
Tip**
multifin convectors
Combination Price:
The actual output in square feet of catalog rating-Steam (215*F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination.
The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered.
SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS
cabinet tVP
description
Trad* Price
Mr dll
unit itr charso
Stock Model
j K | Floor Type-free standing............................................................ j $0.62 j $17.60 Note: Price shown for estimating purposes only. For expended prices, sec page iS. For cabinet extras, see page SO.
Special Service
F FG W
FS FSG
S
FR FRG FRGB
PR PRG
PRGB
Floor Type-free standing............................................................ Floor Type-free standing-inlet grille..................................... Wall Hung-flat top.......................................................................
Free Standing-sloping top.......................................................... Free Standing-sloping top-inlet grille................................... Wall Hung-sloping top...............................................................
Fully recessed-v," beveled edges............................................ Fully reeessed-i/^" beveled edges-inlet grille..................... Fully recessed-*;," beveled edges-inlet grille with
bottom overlap and liner bottom..........................................
Partially recessed-114". IVi", 3", 5' flanged edges............ Partially recessed-1 14", 214", 3", 5" flanged edges-inlet
grille ............................................................................................ Partially recessed-1'4", 214". 3", 5" flanged edges-inlet
grille-with bottom overlap and liner bottom....................
$0.74 .74 .74
.69 .69 .69
.75 .76
.75 .77
.77
.77
$2121 24.37 2121 22.37 25.54 20.15
22.37 26.54
26.12 2549
26.94
37.14
TypW
iDliffiinii
Type FR {Type FRGB shown) See page 52
Note: For cabinet extras, see page 50.
For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifln convectors:
Multifin stock model -- 1.13 pounds. Also see page 46.
Multifin cabinets (less element) -- 114 pounds.
Multifln cabinets (with element):
Types F, FR. PR - ltj pounds.
T y oe* FF, W
-- 114 pounds.
'I'l-pe C.
-Impounds.
Orderln' f-ranijiei:
Stock Motel Multifin with an optional feature: i K-840-24 Muitifin with Metal Trim Strips.
Special Service Multifin with an optional feature:
: ?'.*
32-214 flange, Multifin wii-i ..nuo Damper.
Page 47
HH-12
01564
CONVECTORS
d AMERICAN STANDARD
HYDRONIC HEATING
MULTIFIN CONVECTORS - continued
eonvwtr longth inch**
20 24
28 32 36
40 44 48
56 64
Elements only (when sold less cabinets) -- two-pip* stoam or hot wafer
No. 4 depth
No. 6 depth
No. 8 depth
No. 10 depth
approx.
unnoi.t
shipping walght
Trado Price
unit no.
approx. hipping
woight
Trado Prieo
unit no.
approx.
hipping Trad.
weight
Pile.
aetm.
unit no.
aMMpi(etiintc
Trodo Prico
420 8 424 10
428 12 432 14 436 16
440 18 444 20 448 22
456 26 464 30
$13.86 15.02
16.17 17.36 18.67
20.30 21.67 22.94
25.52 28.22
620 13 $17.00 624 16 10.05
628 19 20JO 632 22 21.73 636 25 23JI
640 28 644 31 648 34
2SJ0 27.06 28.93
656 40 664 46
32J3 35.92
820 15 824 19
828 23 832 27 836 31
840 35 844 39 848 43
856 51 864 59
$20.06 23J1 24J6 27.06 29M
31J7 33.94 30.14
40J7 44.72
1020 1024
1028 1032 1036
1040 1044 1048
10S6 1064
21 26
31 36 41
46 51 56
66 76
*23.10 26.79
29J7 32.70 30.10
39.05 41.00 44.44
49.50 S5JS
Ncic Elements only are furnished less floor supports. Muitifln elements for special one-pipe steam header application--net available.
Orderiaf Example: 1-420 Multifin Element oniy-no cabinet
Ratings:
Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee.
Standard Cabinets:
Standard cabinets are furnished in prime painted sheet steel-reinforced. Ho. 18 gauge front and No. 20 gauge back, ends and top, rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convecton as cur rently catalogued.
MINIMUM CABINET HEIGHTS WITH DAMPERS FOR MULTIFIN AND ARCO CONVECTORS
Type cabinet
Multifin
Are. Calf Iron
F, FG W
F5. FSG S FR. r RG. -'RGB
PR. PRG. PHGB
20" For all depths 20" For all depths 20" For all depths 20" For ail depths
20" For all depths 20" For all depths
24" For all depths
24' For all depths 24" For all depths 24" For #4, #6, #8 depths-32" For #10 depth 20" For all deptha 20" For all depths
Cabinet heights shown for types W and S are nominal heights, actual heights are 9' less. Cabinet heights for Arco Cast Iron convectors applicable to X-4 (underneath) connections only.
HH-12 See page 52
Page 48
01565
, ^AMERICAN STANDARD
hydronic heating
CONVECTORS
ARCO CONVECTORS
SPECIAL SERVICE LINE wh*n sold in combination with standard cabinots
COMBINATION PRICE:_____
The actual output in square feet of catalof rating-Steam <21S*F) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination.
The totel price of each order equals the amount of catalog
square feet ordered multiplied by the price per square foot. plus the unit extra charge multiplied by the total number of units ordered.
SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS
Cabinet typ#
diKrlptiM
F Floor Type-free standing___ FG Floor Type-free standing-
inlet grille.............................
W Wall Hung-flat top................
FS Free Standing-sloping top ...
FSG Free Standing-sloping topinlet grille.............................
S Wall Hung-sloping top.........
FR Fully recessed-?:," beveled edges......................................
FRG Fully recessed-?;," beveled edges-inlet grille ..............
FRGB Fully recessed-';," beveled edges-inlet grille with bottom overlap and liner bottom....................................
Trade Met
pqefrt
unit extra chart*
32.43
330.17
2.43 2.43 2.43
33.83 30.17 31.74
2.43 35.23 2.43 31.74
2.43 30.17
2.43 33.80
2.43 36.84
cabinet type
dMcriptlen
PR Partially recessed-IVi", 2V4", 3", 5' flanged edges...........
PRQ Partially recessed-IVi". 2Vi". 3*. 3' flanged edges-inlet grille .....................................
PRGB Partially recessed-IVi", 2Vi", 3*. 3' flanged edges-inlet grille--with bottom overlap and liner bottom.................
w Trade PHea
par unit extra so ft charge
SJ2
834.85
2J2 33.39
47.43
Standard Cabinets are furnished In:
Prime painted sheet steel-reinforced. No. 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors listed in cur rent literature.
For illustrations of cabinets, set page i7.
For cabinet extras, see page SO.
Ordering Exanplt: 1-M58-20 Arco Convector Unit X-4 Hih
For estimating shipping weights of Arco Convector Units use:
lt pounds per square foot for cabinet portion. 3 Vi pounds per square foot for element portion.
ARCO CONVECTOR -- steam or water
ELEMENTS ONLY (when sold less cabinets)
convector length Inchoc
No. 4 3i/i" depth
aopros.
unit nipping ^Trade
no.
weight
Price
No. 6 5%" depth
unit no.
approi.
chipping ^Tnde
weight
Price
No. 8 7%' depth
unit no.
approx.
chipping _Trade
weight
Price
No. 10 9W depth
unit
no.
approx.
chipping wTrade
weight
Price
18 418 39 12232 618 57 $ 33.23 818 71 3 41.88 1018 84 8 80.43
23
423 50
29.19 623
73
42.83 823
92
54.20 1023 110
68.25
28
428 61
35.71 628
90
52.49 828 113
66.53 1028 136
80.19
33
433 72
42.30 633 106
62.34 833 134
78.71 1033 162
94.93
38
438 83
43.82 638 123
71.97 838 155
90.82 1038 188
109.89
43
443 94
5521 643 139
91.69 843 176
103.14 1043 213
124.68
48
448 105
61.71 648 146
91.25 848 197
115.47 1048 238
139.83
53
453 117
68.29 653 172
100.88 853 218
127.79 1053 264
154-57
58
458 128
74.80 658 189
110.59 858 239
140.08 1058 289
169.39
S3
463 139
81.47 663 206
120.37 863 260
182.31 1063 314
184.12
Ordtrlrtj Etimplt: 1--418 Arco Cist Iron Element only-No Cabinet X-4 Vi t Vi
Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets.
for sizes not listed above-price on application.
See page 43 for minimum cabinet heights with dampers.
"W See cage 52
Page 49
HH-12
01566
CONVECTORS
d AMERICAN STANDARD
HYORONIC HEATING
CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS
CABINET EXTRAS--STOCX MODEL MULTIFIN ONLY
ITEM
DESCRIPTION
DAMPER
Knob Operated Damper Package ....................................
METAL TRIM STRIPS
For recessing stock models only 20" to 36" long ......................................................................
40' to 64" long .......................................................................
GRILLE
Snap-on Inlet Grille for Stock Models Only ....................
AIR VENT
Air chamber with extended tube, manual vent .............. Air chamber with Dole No. 20JR auto-vent ......................
*Nota: Itam* alto availably for special tarvica Multifin.
Trade Pries
t 6.05
10.40 13.31
4.62 6.69 M9
SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS (Prices Indicated are for standard catalogued sizes only)
ITEM
DESCRIPTION
Trade Price
OAMPER
Knob or Institutional Type ................................................................. each
$ 7.21
ACCESS DOOR
In standard locations 1, 2, 3, 4, 7 or 8 as shown in current literature.
Hinged type with Slotted Head operator .......................................... each Hinged type with Allen Head operator ............................................. each Note: Access doors in other than standard locations
7.21 IAS Pric* on application
TAMPER PROOF SCREWS
Phillips or Allen Head screws (other than standard Slotted Head) per cabinet
1.16
CAM LOCKS INSULATION
Allen Head Cam Locks (Allen Keys Not Furnished): Types F. FG. FS and FSG..................................................... per cabinet Types S and W (Multifin Only) ............................................ per cabinet
Types FR FRG. FRGB. PR. PRO. PRGB {$ ;;;;;
Not*: Additional chare* pet ord*r $5.20 1
5.94 6.94
29.18 32.78
Vi" Celotex or Fibreglas on outside of cabinet
Back only................................................................................ per cabinet
12.21
Back, ends and top.................................................................................percabinet 16.07
Vi" Millboard on outside of cabinet
Back only ................................................................................ per cabinet
28.60
Back, ends and top................................................................................ percabinet 40.65
SOUND DEADENING MATERIAL
Approx. Vi" thick-inside front panel only............................. per cabinet
12.10
SEALING STRIP
For standard length FR, FRG and FRGB cabinets only (V*" x Polyurethane) ..................................................... per cabinet
5.06
STIFFENER
All fronts 46' and longer, or 32" and higher have stiffening channel spotwelded to inside front in horizontal position at no additional charge. Stiffening channel on fronts other than
standard ...................................................................................... per cabinet
1.71
METAL TRIM STRIPS
For recessing Types F and FG Multifin convectors only
Cataloged heights and lengths up to 36~........................................ each Cataloged heights and lengths 40" to 64'...................................... each
11.66 14.36
END POCKETS
Specify right or left hand side
4" end pocket with No. IB gauge vertical baffle...........per end pocket 8" end pocket with No. 18 gauge vertical baffle............. per end pocket
6.49 10.40
KNOCKOUTS
Are optional-Furnished only on request
Pnc* on application
HEAVIER GAUGE CABINETS
Trade Price per square foot of cabinet output Front Only
No. 18 gauge...................................... No. 16 gauge...................................... No. 14 gauge......................................
$-- .08 .15
Linors Only
$.08 .10
not *vailtbl*
HH-12
yr See page 52
Page 50
01567
^AMERICAN ksiSTANDARD
HYDRONIC HEATING
general
INFORMATION
BOILER RATINGS
The net I=B=R boiler ratings represent the maximum net loads that may be connected to the boilers. The net I=B=R steam ratings are based on a piping and pickup allowance of 1.333 except where cr. appropriate piping and pickup column is shown. Steam sq: ftrratings are based on 240 Btuh per sq. ft. The net I=B=R water ratings in Mbh are based on a piping and pickup factor of 1.15. Water sq. ft ratings are based on 150 Btuh (170* water) per sq. ft. For installations having unusual piping and pickup requirements, AmericanStandard should be consulted before selecting a boiler.
For forced hot water heating systems where the boiler and
piping are within the area to be heated, the boiler may be selected on the basis of its gross output.
Sufficient radiation must be installed for the riinrmnt; of the building to be served.
In order to select the proper size boiler, calculate the heat loss of the building, then divide this Agure by 1,000 to get the heat lots expressed in Mbh. Select a steam or water boiler which has a net I=B=R Mbh rating equal to or greater than this Agure using the appropriate steam or water column.
See current literature for determining the size of radiators and convectors for hot water systems.
GAS FIRED BOILERS
American-Standard Gas boilers are design certiAed by the American Gas Association.
Ratings shown are for installation at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
OIL FIRED BOILERS
The Aring rates or I=B=R burner capacities -- gallons per hour--are based on the use of oil having 140,000 Btu per gallon heat value.
STOKER FIRED BOILERS
The Aring rates or I=B=R burner capacities--pounds per hour--are based on the use of coal having 13,000 Btu per pound heat value.
HAND FIRED BOILERS
The ratings are based on the use of stove or nut size bitumi nous coal, anthracite coal or coke with 13,000 Btu per pound heat value. See table below for selecting proper size boiler when using coal with less than 13,000 Btu per pound.
BUILT-IN TANKLESS WATER HEATERS for G-2 Water. G-40. G-10. A-3. FR-A-5. A-5, DPT. PFA-3. PFA-5. and VPT
All tankless type built-in water heaters are rated in gallons per minute on the basis of a minimum boiler water temper ature of 200* F. The maintaining of 200* F boiler water temperature with rated flow through a tankless type builtin water heater is dependent on the output of the boiler.
Increase the boiler size 12 Mbh for each bathroom in excess of two.
In those areas where excessive lime exists in the water, use of built-in tankless type water heater is not recom
mended except when provision is made for regularly clean ing the heater.
EXTERNAL WATER HEATERS FOR AMERICAN-STANDARD STEAM BOILERS
External tank or tankless type heaters can be connected to all American-Standard Steam boilers when provision is made in the supply and return piping of the heating system.
When an external tank type heater is used and the domestic demand exceeds 75 gallons in a 24 hour period, increase the boiler size 120 Btuh for each gallon of storage tank capacity.
When an external tankless type heater is used, increase the boiler size 12 Mbh for each bathroom in excess of two.
(Note: G-10 Steam boilers can be provided with external water heater tappings for water to water heat exchangers. See G-10 optional equipment pages for price and availabil ity. A-7 boilers are regularly provided with tappings for external water to water heat exchangers.)
WHERE COAL HAS LESS THAN 13,000 BTU CONTENT
When selecting hand Ared boilers for burning coal of lower heating value than 13,000 Btu per pound the following cor rection factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq. ft.).
heallnc value of cool
correction factor
13.000...................... 1.00
12.500..................... 1.04
12.000..................... 1.08
11.500.................. 1.13
11.000
1.18
hooting valuo of cool
correction foctor
10,500...................... 1.24 10,000...................... 1.30
9.500......................1.37 9,000 ....................1.44
INSTRUCTIONS FOR ORDERING GAS BOILERS:
Spscify complete boiler number.
Specify type of (is (whether natural or propana), Btu (heat value of gas), specific gravity.
Specify elevation at point of installation if in excess of 2,000 feet and indicate barometric pressure.
In addition, for Prstrure fired PfA-S pot fired and gat*oil fired units, specify 90s pressure at gas train inlet.
Specify optional equipment In detail.
BOILERS:
REPAIR PARTS For current price, contact your American Standard distributor
Refer to Boiler Repair Parts Catalog Form 9100-2 Dated 3/1/71 ..............................................
OIL BURNERS: Refer to "American Standard Arcoflame Oil Burner Repair Parts Catalog" 1966 Edition & Supplements.
Page 51
HH-12
01568
GENERAL TERMS
d AMERICAN STANDARD
HYORONIC HEATING
TRADE PRICE BOOK
Illustrations and descriptions of ordering Numbers listed In this price book will be found In the current American-Standard Hydropic Products Catalog and literature. Hems illustrated in product literature and not included In this price book are discontinued, me illustrations in this jyIce book although actual representations of certain products In the line, do not necessarily show sizes and details of all products in the line.
This price list has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown are guides only and do not purport to represent actual prices prevailing in any particular market and are not intended to interfere with our distributors' right and responsibility to establish their own resale prices.
All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein.
INVOICE MINIMUM All distributors' orders. Including repairs, which aggregate less than $15.00 net will be billed at $15.00.
TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY
AMERICAN-STANDARD THROUGH U.S. PLUMBING/HEATING TO ITS DISTRIBUTORS
All sales of goods by American-Standard through U.S. Plumbing/Heating to its distributors are made subject to terms and conditions printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions, are as follows:
MICC
Goods sold by the Seller will bo billed to tiie Buyer recording to the pncoo and terms contained In its current bulletins end price books. In tho case of orders for goods lor which no price M currently in effect the price will be determined by the Seller and set forth in tho Invoice Issued after shipment of tho goods.
Twos. Any tax or other Government charge now or hereafter levied upon me production, sale, use or shipment of goods ordered or sold, will bo chargod to and paid for by the Buyer.
endeavor to secure for Its direct Buyers the benefits of warranties sxtended by such other manufacturers lor such goods.
American-Standard is proud of Its record for product quality and for fair ness In handling warranty matters; and. If an ultimate user of our products should fool our warranty tystam doeertbod above does not work fairly in his case, he should write the Office of the President Oirsctor of Consumer Affairs. U. S. Plumbing/Hosting, AmortcaivSUncard. 40 West 40th Streat. New York. N. Y. 100IS.
CONTRACT WTTN BUYEft
DELIVERY
Transportation Alike. Delivery to the Initial carrier shell constitute delivery to the Buyer. The Seller's responsibility cesses upon delivery in good order to suen earner, and til goods are shipped at the Buyer's risk.
The Buyer te urged to examine all deliveries carefully before signing transportation receipts, if goods are visibly damaged, the Buyer should msist that written confirmation of the damage be noted on the freight bill or dray ticket by the agent of the earner, if damage Is discovered after unpacking, the carrier should bo notified at once, so that inspection can bo made and the claimed damage substantiated by the carrier.
Interference with Delivery. The Seller has no obligation to deliver good* against any order until it has sccspted ths order by Issuance of its acknowl edgment of order, in any event, the Seller will net be liable for tny delay or failure in the delivery or shipment of goods against an accepted order or tor any damages suffered by reason thereof, when such delay or failure Is. directly or indirectly, due to accident (In manufacture or otherwise), fire, flood, not. war. smbargo. labor stoppages. Inadequate transportation facili ties. shortage of material or supplies, deity or default on the part of its vendors, regulation by Government authority, or any like or dissimilar cause beyond its control.
CONSUMES PROTECTION -- WAARANTY
American-Standard products normally resell owners or consumer-users through an industry channel of distributors and plumbing and heating con tractor!. Experience hes shown that claims of defects in our products gen erally relate to abuse or to other damage which occur after our sale and are not our responsibility. Since determining proper responsibility requires local Inspection, our warranty (set forth below) extends only to our direct buyers; distributors art best equipped to obtain die facta underlying claims, to place responsibility whore it belongs and to recommend/handle repair or re placement.
American-Standard warrants only to Its distributors and other direct Buyers that it will furnish by freight a replacement for. or at Its option repair, any product of its manufacture or part or portion thereof, proved to its satisfac tion to be defective in material or workmanship under normal use and service within one year after installation.
There is no other warranty, express or implied. Including no implied war ranty ef marchanlability er Implied warranty for fitness for s particular purposa and American-Standard will net ba responsible for any damages whatsoever, nor for labor or transportation espenaoe relating to such re placement or such repair, nor wilt it be held responsible for warranty adjustments costing mors than ths price of the product to Its distributors and other Oirsct Buyers.
ficeaptears of Orders. Orders will be accepted only by the Seller s usual acknowledgment of order containing terms and conditions applicable thereto. No torma and condition* appearing in a Buyer's order that are at variance with die Seller's terms and conditions shell be binding upon tho Seller unteee specifically agreed to by M In writing. Unless the Seller spe cifically re agrees in writing In acknowledging any order, any terms and conditions appearing m a Buyer's order contrary to those slated heroin and in such acknowledgment of order are to be deemed waived by the Buyer. Receipt by the Buyer of the acknowledgment of order without prompt obiac* tion to the terms and conditions therein and herein set forth, constitute acceptance by tho Buyer of such terms and conditions.
Cancellation of Orders. After the Seller's acknowledgment of order has been issued. an order may be modified or cancelled only upon written agreement by the Seller. Orders for goods other than those of standard manufacture will not be cancelled after e commitment has boan mad* or production scheduled.
Credit tor Returned Goods. Merchandise may not be returned for credit unless the Seiler hes agreed to accept it Where returns are accepted, a deduction of 10% or SIO, whichever is greeter will be made lor rehandling. All transportation costs for returned goods must be paid by the Buyer, in any event only saleable merchandise of standard manufacture may be returned for credit
Credit Approvat Buyers' orders ere accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stooped m transit on accepted orders without any liability on the Seller's part, if. m Its opinion, the Buyer's ability to pay tor the merchandise on these terms and conditions is in doubt
SHORTAGES OR VARIANCES
No claims for variances from or shortages in orders will be considered uniats presented within 60 days after receipt of goods.
PRODUCT AND PACKAGING CHANGES
Factors beyond the control of the Seller and the need for continuing im. provemenl of product require the making of changes from time to time m products and their packaging. The right Is reserved to msfcs rsasonaoie changes of any kind without notice and to delivar rsvissd designs or models of good# against any order, unless on the face of the acknowledgment or order this right is specifically waived.
The Seller shell have no responsibility whatever with rasped to changes made by the manufacturer in products or their packaging sold but not manufactured by the Seller.
SHIPPING WEIGHTS
Goods of other manufacturer* sold by American-Standard are not warranted unless accompanied by an eipress written warranty, put the Seiler will
The shipping weights given harem ere approximate, for Buyers con venience only, and are not guaranteed.
.AMERICAN 51 STANDARD
PLUM8INC / HEATINC . 0 IOI 2003 NEW XUNSWICK. N l. 0l03
HH-12