Document Qg4xXQwBnZaGYYpryL9LnLk98

r "1 -4 *3 i: . i t -4These nethods are standard for Industrial hygiene practice. DISCUSSION Several engineering and health criteria Indicating a need for a re-cvaluatlon of the oven rood In Department 14 were Mentioned in a letter to Mr. V. C. bceder, dated March 17, 1964. Recent chemical analyses of air samples collected within the oven room indicate dlacetone alcohol vapor concentrations exceeding the threshold limit value. Dlacetone alcohol ordinarily presents only a low degree of hazard to health in industrial handling. While capable of causing systemic Injury at high concentrations, dlacetone aiconol has good warning properties (Irritation of the eyes, nose, and throat) so that acute systcqle Injury, even ulld narcosis, should not occur under the normal conditions round In Industrial operations. There are no repor ts In the literature of toxic' effects to humans resulting from the Industrial handling or dlaoetouo alcohol. However, the literature also states that there U not adequate data available upon which to establish a safe level for prolonged and repeated vapor exposure. The 'threshold Unit of 50 P.F.M, Is probably based upon human comfort. Table VI Indicates that employees wording within the oven room are exposed to concentrations at their work stations exceeding the threshold Unit value. gecosBemdatlon 1 was made oa the basis of empirical and chemical data. If It Is not possible to correct the ventilation system within six Months, It may he advisable to have kidney and liver function testa performed on the oven room employees. It Might be added that these employees should not toe needlessly alarmed particularly If theae testa can be performed In the course of a routine physical examination. tfcployeea in Department 33 are exposed to solvent vapor levels below the threshold Halt value, fable X Indicates that the employe* at the open dip tank receives an exposure of 650 P.F.M. This nan'a exposure when considered over an 0 hour day is below the threshold llnlt for Methyl ethyl ketone. It Might be suggested that the local exhaust ventilation on the cementing bench be enhanced by extending the hoods to the area where parts are painted. Tables IX and 111 Indicate employees in Departments 07 and 09 are exposed to toluene vapor In concentrations below Its threshold, fable lit Indicates that raw rubber In the con tainers by the various eheeter mills provides a source of toluene vapor exposure. This concentration can be minimised by providing lids for the containers. A reecsmendatlon was made to this effect. fable XV Indicates the trlchlorethylene degreaser Is leaking. At the time of sampling it was recoaaaended that the windows I . VMGOI-0000270