Document Qg0b5pY6MEmOZav0kz4JEZmLo
Pumps:
Economy Pumping Machinery Co.
General Sales Offices
3431 West 48th Place, Chicago, 111.
DISTRICT SALES OFFICES
Amsterdam. N.Y., 447 Guy Park Avenue
Baltimore. Md.. <522 Park Avenue
*
Boston, Mass., 141 Milk Street
Detroit, Mich.. 517 E. Larned Street
Grand Rapids, Mich., 301 Peninsular Building-
Miami, Fla., 938 N.E., First Avenue
New Orleans, La., 901 Carondelet Street
Wichita, Kans., 1100
New York City, 39 Cortlandt Street Oklahoma City, Okla., 710 Hudson Street
Philadelphia. Pa.. Bourse Building Pittsburgh, Pa., Fulton Building St. Louis, Mo., 2741 -Washington Boulevard St. Paul, Minn., 308 Metropolitan Building
San' Francisco, Calif., Monadnock Building Douglas Avenue
Economy Pumps and Receivers
Economy pumps and receivers are made in a variety of types for every-pressure and capacity conditions. The present line is the result of a long study and improvement by this Company which was one of the pioneers in the manufacture of Electric pumps and receivers.
The use of these pumps to improve circulation with a reduction in boiler pressure usually results in large fuel economies. The savings are particularly striking in the case of medium pressure plants where it' is desired to work at low pressure during dull periods of'the day.
The table below gives a partial list of sizes which are available in either solid shell or horizontally split mm* designs. Complete specifications and descriptions will be found in Bulletin No. 405.
All Economy pumps are substantially mounted on cast iron bases with machined pads. Either cast iron or steel receivers are used. The automatic control is assembled as a unit and is easily accessible for inspection at all times. The most important features of individual standard designs are given below.
Type CSS--A single suction solid shell unit with oil-less stand bearing and outboard ring oiling or radial ball bearing. The most popular of all Economy pumps and receivers; a thoroughly dependable unit at a moderate price.
Type CSM--A double suction horizontal split case unit with enclosed bronze impeller with ring oiling bearings. This unit has been designed for use where the service is unusually severe as where equip ment of the highest grade is desired.
. Type CST--Multi-Stage Pumps for pressures above 40 lb. They are bronze fitted with ring oiling bearing at the driving end and radial ball bearing at the outboard end.
No. of Unit
6 6>/2 7 7Vi 8 8V2 9 9!/2 10
Capacity in
Sq. Ft. Direct C. I. Radiation
2000 3500 5000 7500 10,000 15,000 25,000 35,000 50,000
Pump Capacity
m 12 15 20 25 37 60 80 110
Receiver
cB?f
13 16 20 26 33 41 49 57 82
10 lb.
M 'A/} Vi V, 1 v/2 2
560
Motor Horsepower
151b.
251b.
601b.
1001b.
y* Wf
y. IVj 1 I'/z 12 23 23 25
35
35
35 5 5-
5 10 Wl 10 m 15
Economy Pumping Machinery Co.
Pumps
. -------------------------- ------------- "i - -*"F
Economy Double Suction Single Stage Pumps, for hot water circulation, brine circulation, water supply, etc., are
made.in a complete range of capacities up to 3500 g.p.m. They embody the newest hydraulic developments which give them an unusually high efficiency over a broad range. The mechanical design is rugged and simple so that reliable per formances and long life is assured. A head capacity table is given in Bulletin No. 408.
Economy Centrifugal Return Line Vacuum and Boiler Feed Pumps
** ^
^fDconomy Vacuum Pumps have been designed for the rapid removal
of air and water from heating systems and discharge of the water to the boiler. They are made in a wide range of sizes, a partial list of which is given below:
Bronze Fitted Pumps, Air Eliminator, Vacuum Receiver and Automatic Control are standard equipment. Sizes over 5000 sq. ft. . capacity are of a double suction horizontal split case construction. Standard units' are supplied with bronze suction strainer and scale pocket. Entire apparatus is shipped completely assembled and wired in accordance with National Electric Code.
Economy Centrifugal Vacuum Pump
Type 2254
Duplex Units consisting of single tank, two pumps, motors and control can be furnished in any size. A test with calibrated orifices is made on each unit before shipment.
Standard Pumps are - designed for operation against 20 lb. pressure but reasonably prompt delivery can be made on units .for discharge pres sures up to 150 lb.
Unit No.
CV-I CV-2 CV-3 CV-4 CV-5 CV-6 CV-7 CVS CV-9 CV-IO
Capacity in Sq. Ft.
Direct C. I. Radiation
Motor
Horse Power
Cubic Feet Air per
Min.
Size DU.
charge to
Boiler
Size Re-
turn
Inlet
2.500 5.000 8.000 16.000
20.000 27.500 40.000
65.000 100.000 150,000
y.
J'/2 2 3 5 5
7'/, 10 15
iy. 4.
6 10 15 19 24
40 60
90
,y< 'I'/z 12
1. .2V2
I'/, 3 kly. 3
ft
15 6
I'A 6
Ship-
vF*
650 750 900 1.025 1.150 1.300 1.550 1.800 3.100
Economy Multi-Stage Pumps
Made in the horizontal split type in sizes and larger, smaller sizes are
vertically split. In these pomps the head per stage has been limited to a
figure at which high efficiency and long life is obtained. Distinctive features of Economy Horizontally Split design are solid one piece bronze diaphragms,
the volute in every stage and the hydraulic balancing device. The table
-.
Type EMF
shows* maximum head at 1750 r.p.m. Higher pressures are obtained with 3--6---0--0---r-e---v--olutio"n "u"ni"ts. uSypcueucUifitcUaUtiUonDsiUaCre gglVivCeQn LiDn JBulletin No. 406.
Multi-Stage Pumps for High Pressure House Supply Boiler Feeding, Etc.
Capacity, gallons per minute........ Pump number...........................
Horsepower for each 100 ft.'head!! Maximum head at 1750 r.p.m.___
25 50 100 160 250 350
ft ft2.5 3'%
300 400 600
33 11.0 17.0 750 750 550
Economy Underground Pumps and Receivers--Type CU
Underground pumps and receivers are designed for use where radiation is placed on the floor with returns underground or in any other places where it would otherwise be necessary to install horizontal pumps in a pit.
The underground pump consists of special vertical pump which b bronze fitted and controlled by a special mechanism which prevents binding and sticking of float rod. Lower bearing b of the oil-less type which has given such excellent service in these pumps for the last twelve years.
When necessary to use an underground pump on high pressure jobs we recommend the use of a low pressure underground pump discharging into the receiver of a high premure horizontal pump. Our engineering department will be pleased to work out the details of such installations.
Capacity Sq. Ft.
Hp., 101b. Discharge Pressure
2000 y.
3500
5000 8 7500 A
Type CU. Underground Pumps and Receivers
Type CU
Motor Hp. 201b.
y.
1ft
Pump Receiver Capacity Capacity G.p.m. Inches
.ft
15 20
24 x 30 24x30 24x30 24x36
Disch. Size Inches
1
1
l1'/%4
Capacity Sq. Ft
Hp., 10 lb.
Discharge Pressure
10,000 15.000 25.000 50.000
Vi
ft 3
Motor Hp.
20 lb.
Pump Receiver Capacity Capacity G.p.tn. Inches
Disch. Size Inches
P'A 25 24x36 37 30x36 60 30x48 5 no 36x48 V/l
561
/.