Mr. Howard Forrest cutting pipe covering in test of new, economical dust collector (far left.)
Now Available: An Effective
Economical Dust Collector
An effective, economical dust col lector is now available for use with band saws, other powered equipment, and for general cleanup.
Environmental tests made on it at the Howard Forrest Co. factory, Houston, Texas, demonstrated the effi ciency of the system. In these tests, made during the cutting of five-inch diameter pipe covering, airborne as bestos levels remained well below the new emergency standard for airborne asbestos dust.
High-Velocity Collector
The measurements were made in an enclosed area designed to repre sent a typical fabrication shop.
All measurements, taken at various locations in the room and in the breathing zone of the saw operator, showed dust levels to be less than 1 fiber/milliliter (longer than 5 mi crons) during SO cuts on the material over a 10-minute period of time.
The collector developed by Howard Forrest is of the high-velocity type. It gains its effectiveness by establish ing an air stream along the saw blade
having a velocity several times that of the blade. As this air stream is di rected to the collector, virtually all asbestos debris is carried along.
To Sell For Lest Than $400
For the past two years, following earlier tests that showed this collec tion method to be especially effective (reported in Vol. 1, No. 4 of Insula tion Hygiene Progress Reports), all Forrest saws have been equipped with an inlet pipe to which a high-volume collector could be attached.
What is unique about the Forrest collector is the low cost. It is designed to sell for less than $400, a fraction of the cost of a small band saw.
An emergency standard for con trolling occupational exposures to as bestos was announced by the Depart ment of Labor on Dec. 7, 1971.
Acting under the provisions of the Williams-Steiger Occupational Safety and Health Act of 1970, the Labor Department established a limit of S fibers (longer than 5 microns) per milliliter of air for the time weighted average concentration of airborne as bestos to which a worker may be exposed. (See page 4 for details).
Certain provisions of the emergency standard are of particular importance to insulation workmen and contrac tors. It is now mandatory that as bestos cements and mortar be mixed in closed bags, that all waste be dis posed of in sealed containers, and that vacuum cleaners be used for cleanup.
Standards Long Urged
Tests by the Insulation Industry Hygiene Research Program of the use of plastic bags for the mixing of ce ment have demonstrated their feasi bility. In-bag mixing can reduce at mospheric dust levels to 1/10 that found when the cement is dumped in a trough or tub for mixing.
It is expected that such procedural requirements will be expanded in the permanent standard which must be issued before June 7, 1972.
Procedural standards have long been urged for adoption by the IIHRP. The use of plastic mixing bags, dust collectors on powered tools, adequate cleanup, down-draft cutting tables, and coated asbestos block all reduce workers' dust exposure
On Jan. 12, 1972, the Department of Labor published in the Federal register a proposed permanent stand ard for asbestos dust. This publication is the first step in the process of adopt ing a final standard. Written and oral comments have been solicited by the
(Continued ott fourth page)
398479
Insulation Hygiene Progress Reports
*- 4, N*. 1
from the
Serine 1*72
Four Single-Use Respirators to Choose From
How Makers
In alphabetical order, here are de
scriptions of available respirators, as sent to us by their manufacturers:
Insulation Industry Hygiene Re search Program
Editor: W. J. Nicholson, Ph.D., Published at the Environmental Sciences Laboratory (Irving J. Selikoff. M.D., Director I, Mount Sinai School of Medicine of the City Uni versity of New York, New York, N.Y. 10029
Advisory Council of LLHRP
In this issue of Insulation Hygiene Progress Reports disposable respira tors from four companies are de scribed. Each of these will provide useful respiratory protection for as bestos workers during virtually all in sulation work. Spraying of asbestos, however, or removal of old insulation will require air-supplied respirators.
The emergency standard promul gated by the Department of Labor requires respiratory protection when certain airborne dust concentrations are exceeded. See Section (a) of the Standard (page 4 of this issue).
AMERICAN OPTICAL CORPORATION
ST00U661 5
Irving J. Selikoff. M.D. Program Director and Chairman
E. Cuyler Hammond, Sc.D., Vice President, American Cancer Society, New York, N.Y.
Albert Hutchinson, General President, International Association of Heat and Frost Insulators and Asbestos Workers, Washington, DC.
Fred L. Pundsack, Ph.D. Vice Presi dent, Research and Development, Johns-Manville Corporation, New York. N.Y.
PURPOSES OF THE INSULATION
INDUSTRY HYGIENE RESEARCH PROGRAM
1, To develop improved methods for minimizing ex posure of insulation workers to dusts and fumes encoun tered in their work. 2. To disseminate knowl edge of these improved methods of dust control wherever they may be ap plied advantageously and to offer cooperation, advice and assistance toward their universal adoption.
When to use a Half-Mask Type
For atmospheres containing not more than 25 fibers per milliliter (greater than 5 microns in length) over an 8-hour average, or more than 50 fibers per milliliter over a period of 15 minutes, a half-mask respirator ap proved under Schedule 21B of the Bureau of Mines or a valveless respi rator providing equivalent protection shall be used.
The four respirators shown here satisfy the criteria of the emergeny asbestos standard. In addition, a Bureau of Mines Schedule for valve less respirators will soon be published. In preliminary tests, each of these respirators met the standards of that schedule or of Schedule 2IB.
These Require No Maintenance
To obtain the respirator informa tion shown here, all respiratory equip ment manufacturers were invited to submit descriptions of their single-use respirators for this issue. Four re sponded and we print their replies.
Single-use respirators were devel oped for the specific purpose of mak ing available protective devices which do not require maintenance. They are intended for use during one shift or one day and are then to be dis carded.
To be effective, however, they must be properly fitted and worn in accord ance with the manufacturer's instruc tions. The variety of respirators shown here will allow a workman to choose the type that is most accept able to him and best fits his face.
Initially, local safety equipment supply houses may not have these respirators in stock. However, pur chasing arrangements can be made by writing directly to the manufacturers.
The AO R1050 respirator will util ize a fibrous filter dement of large area to insure both a low resistance to breathing and a large storage capacity for retained dust particulate.
A malleable metal frame attached to the periphery of the fibrous filter element will permit the respirator wearer to shape the element to fit his face.
A soft gasket composed of a closed cell plastic foam attached to the per iphery of the filter element will seal the respirator to the wearer's face.
The respirator's head harness con sists of two loops of elastic strapping attached to the respirator's periphery at four separate points (two points on each side of the respirator).
One loop of tbe head harness is positioned around tbe back of the respirator wearer's head, above his ears, while the other loop is positioned below his ears.
Tbe respirator will be introduced to tbe market as soon as it has been approved.
- M. A. Bousquet Product Manager Respiratory Protection
- - - American Optical Corp.
, Southbridge, Mass. 01550
' i"-- --------- cCiS* '
398480
Describe their Various Respirators
9I999001S
MINNESOTA MINING
AND MANUFACTURING
The MMM No. 8710 is a low-cost (S.50) single-use valveless respirator which has been tested extensively in the laboratory and in the field.
It was field-tested by insulation workers at the Puget Sound Naval Shipyard in Bremerton, Washington; at the Todd Shipyards in Seattle, Washington; at the World Trade Building in New York City; and at various other construction locations.
It is also being used in the Appren tice Training School of Local 17 in Chicago. All field tests have shown overwhelming acceptance from a comfort standpoint.
The MMM No. 8710 is currently available on a test basis, only, but production is being expanded as rapidly as possible and it should soon be available in most parts of the coun try. It will be distributed through Safety Supply Distributors.
Curtis A. Thorpe Market Supervisor Occupational Protection Products 3M Center St. Paul, Minnesota 550101
SAFELINE PRODUCTS CORPORATION
The new single-use valveless dust respirator to be marketed by Safeline Products will be identified as the Safe line 5350 Single-Use Dust Respirator.
It will be equipped with a fibrous filter unit of exceptionally large area, so that it will have a very low breath ing resistance and will not be plugged rapidly by retained dust particles.
It will contain a formable metal frame attached to the outer edge of the filter unit which will allow the user to shape the filter unit to fit his face. A soft gasket made of a closedcell plastic foam attached to the outer edge of the filter unit will seal it to the face.
The respirator will be equipped with a simple head harness composed of two loops of elastic strap. Lengths of the straps are such that they will insure the respirator is properly sealed to the face and yet comfortable to wear, whether the user has a small or large head.
The ends of the elastic straps of each of the two head harness loops are attached at separate points of the respirator to insure that the respirator is properly balanced on the user's face. This respirator win be marketed after it has been approved.
.. . " George L. Cochrane t . Sale* Manager . . Safeline Ptoducts
Box 550 Putnam, Connecticut 06260
THE WELSH MFG. COMPANY
The Welsh 7165 is a compact, easybreathing, disposable respirator for dusts. It is unusually compact, and yet has a large filter area for out standing efficiency and ease of breath ing.
Economical: The 7165 is inexpen sive enough to throw away daily.
Bureau of Mines approved: Meets the stringent Schedule 2IB.
Company and worker acceptance: Extensive field testing has brought ap proval from major U.S. companies and from workers.
Easy fit: The 7165 is soft, nonirritating, and conforms readily to the face. A soft aluminum band may be formed to nose and cheek contours for a positive seal. In addition, fully adjustable head bands provide good respirator-to-face contact without un due pressure.
Compatible with safety glasses: The compactness, light weight (less than 2 ox.), and the contoured fit allow safety glasses and goggles to be worn comfortably.
Day-long comfort: The large, wrap around filter, and low inhalation and exhalation resistance give a constant circulation of air. Cleaned, cool air comes in through the filter. Hot moist air goes out through the exhalation valve.
Welsh Manufacturing Co. 9 Magnolia Street Providence, R. I. 02909 Phone: 401-351-3400
398481
L I 99 'i00IS
-Excerpts from The New U.S.-
Asbestos Dust Standard
The New Emergency Asbestos Dust Standard published in The Federal Register by the US. Der -rment of Labor includes the following:
(a) The 8-hour time-we.'gnted average airborne concentration of as bestos dust to which employees are exposed shall not exceed 5 fibers per milliliter greater than 5 microns in length, as determined by the mem brane filter method at 400-450X magnification (4 millimeter objective) phase contrast illumination. Concentrations above 5 fibers per milliliter, but not to exceed 10 fibers per milliliter, may be permitted up to a total of 15 minutes in an hour for up to 5 hours in an 8-hour day.
(b) Engineering methods, such as but not limited to, enclosure, va cuum sweeping, and local exhaust ventilation shall be used to meet the exposure limits prescribed in paragraph (a) of this section. Where such engineering methods are not feasible, or do not otherwise reduce the concentrations below those prescribed in paragraph (a) of this section, respiratory protective devices shall be provided and used in accordance with paragraph (c) of this section.
[Paragraph (c) deals with respiratory protection, respiratory maintenance programs and conditions under which specified types of respirators must be used. The main impact of the section for asbestos workers is made clear in the story on pvge 2, column 2, of this issue.]
(d) (1) When an employer has employees who are exposed to asbestos dust exceeding the limits prescribed in paragraph (a) of this section and the exposure results from the operations described in the remaining subparagraphs of this paragraph (d), the employer shall comply with the requirements of these subparagraphs relating to the operations involved. The requirements of this paragraph are in addition to those prescribed in paragraph (b) of this section.
(2) All hand- or power-operated tools which produce asbestos dust such as, but not limited to. saws, scorers, abrasive wheels, and drills shall be provided with local exhaust ventilation and dust collectors in accordance with the American National Standard Fundamentals Govern ing the Design and Operation of Local Exhaust Systems: ANSI Z9.21971.
(3) Employees exposed to the spraying of asbestos or the demolition I of pipes, structures, or equipment covered or insulated with asbestos shall be provided with respiratory protective devices in accordance with paragraph (c) (4) of this section.
(e) Asbestos cement, mortar, coatings, grout, and plaster shall be mixed in dosed bags or other containers.
(f) Asbestos waste and scrap shall be collected and disposed of in
sealed bags or other containers. (g) All cleanup of asbestos dust and blowing shall be performed by
vacuum cleaners. No dry sweeping shall be performed.
Labor Department Consults
Both Labor and Industry
(Continued from first page)
Labor Department and the final stand ard will take notice of these.
To this end, hearings will be held on March 14, 1972, in Washington, D.C., at which labor, industry and other interested parties can supply information relevant to the final standard. -- ''
Commenting on the new emergency standard. Dr. Irving J. Selikoff, Direc
tor of the IIHRP, praised the Depart ment of Labor for promptly acting on the request of labor unions and establishing an emergency standard for asbestos dust
"The recognition of the occupa tional hazard of asbestos and the spec ification of safe means for its use is extremely important," he said. "We have here a good beginning, but much more must be done to establish a safe environment for asbestos workers."
Workers Played a
Major Role in
New Standard
The Asbestos Workers Union, the
Insulation Industry Hygiene Research
Program, and industry played impor
tant roles in the promulgation of the new emergency asbestos standard and
in demonstrating the need and feasi bility of some of its provisions.
The effectiveness of plastic bags for mixing cement was first published in
Insulation Hygiene Progress Reports (Vol. 2, No. 1). Adequate cleanup
and housekeeping have long been advocated.
The need for an effective single-use respirator was first emphasized by
President Hutchinson of the Asbestos Workers Union to the U.S. Public
Health Service as long ago as 1968.
Tests Made by Various Locals
The current availability of these respirators and their acceptability for use in the new emergency standard has followed extensive work by the IIHRP, respirator manufacturers, and the Johns-Manville Corp., which developed the first prototype of a disposable respirator.
Field testing of different respirators
by a number of locals of the Asbestos Workers Union was especially use ful in achieving suitable respirator de sign.
Of particular importance has been the cooperation of Local 12, in New
York, and Local 32, in New Jersey, in participating in a health study of
asbestos workers by Dr. Irving J. Selikoff of Mount Sinai School of Medicine.
This research, along with a related industrial hygiene study of the work environment of Asbestos workers in the New York and New Jersey area has indicated that a serious health hazard exists in the insulation indus try at dust levels of 12 fibers/milli liter, the Threshold Limit Value effec
tive before publication of the emerg ency standard.
Drive for a Permanent Standard
In fact, there is question whether the currently proposed emergency standard of 5 fibers/milliliter is ade
quate. (See Vol. 3, No. 2 for a dis
cussion of this question.) In a continuing drive to assure a
safe permanent standard, both the
staff of IIHRP and President Hutchin
son of the Union will appear to testify
in the hearinp required before pro
mulgation of a final standard, to pre
sent data pointing to an appropriate
standard.
.
398482