Document QYYv0pLnMn45ZNqdpZ3LMgzo
534
CHAPTER 28
1948 Guide'
After the true heat loss is obtained, the loss per square foot of pipe surface can be calculated from the relationship:
ffi " go (rj/ri).
where gi = Btu per (hour) (square foot outer surface of pipe).
The heat loss through two or more thicknesses of insulation applied to a pipe can be.calculated by means of the equation:
Pipe Insulation
535
Solution. In figuring the heat loss from Equation 2, it is necessary to first make an
assumption for the outer surface temperature k and the temperature between the diatomaceous silica and 85 per cent magnesia insulation, so that the mean temperature
of each material can be obtained and-the thermal conductivity corresponding to the mean temperature of each material substituted in the formula. First assume an outer surface temperature of 140 F and a temperature of 570 F between the two materials
con-esponding to a mean temperature of (1200 + 570) 2 or 885 F for the diatomaceous silica and (570 + 140) -5- 2 or 355 F for the 85 per cent magnesia insulation. The
conductivities of these two materials at mean temperatures of 885 and 355 F interpolated from Table 6 are 0.865 and 0.5 Btu respectively.
Fig. 3. Heat Loss Through 2 In. Thick 85 per cent Magnesia Type Covering
go =
tl -- h
rs loge-ft-
r
ri_ . rsloger,
k.
where
r = outer radius of second layer of insulation, inches. rB = outer radius of last layer of insulation, inches.
(2)
The method of solving Equation 2, which is the most difficult of the two, is given in Example 3.
Example 8. Compute the heat loss per linear foot of pipe surface per hour from a 6-in. pipe, insulated with a 3-in. thickness of diatomaceous silica, and a 2-in. thickness of 85 per cent magnesia. The pipe is operating at a temperature of 1200 F and is exposed to a room temperature of 80 F.
Fig. 4. Heat Loss from Canvas-Covered Cylindrical Surfaces of Various Diameters
These values are substituted in Equation 2 and a trial calculation made. For a nominal 6-in. steel pipe r, = 3.312, r, = 6.312 and r = 8.312 then,
1200 - 140__________
8312 loge fill , 8312
0.865
0.5
1060 6.2 + 4.58
98.3 Btu.
The temperature drop from the outer surface of the insulation to the surrounding air for a heat loss of 98.3 Btu is found from Fig. 4 to be 57 F for a 16-in. O.D. cylindrical
surface, or 57 + 80 F room temperature = 137 F surface temperature. Since a surface temperature of 140 F was assumed, it is evident that a temperature closer to 137 F, or, for instance, 138 F should be used for recalculation:
90
1200 - 138 6.2 + 4.58
=
98.4
Btu.
Since the temperature drop through each material is equal to the heat flow times the
actual resistance of each material the temperature drop through the diatomaceous silica is 98.4 X 6.2 = 610 F or the temperature between the two insulating materials is