Document QXwK8XEpxazn2GxNwQ0NEpMRL

GENERA INFOUIiiTICK concern: r:c the handling Q? AROCLOR 1254 By W. E. Alexander Monsanto Chemloal Company Phosphate Division Enpineering Department Anniston, Alabama Deoember 1, 1941 HONS 060030 DISTRIBUTION Twelve copies -were made of this report and distributed as follows: ITo. 1 No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8 No. 9 No. 10 No. 11 No. 12 R. 3. Weatherly R. S. v.'eatharly R. 3. '"eather ly R. R. Cole F. N. ''illlans H\'T .# F.# '.Veaver Durrett R. I. Jenkins J. L. Howerton I. Clecorn IV. K. Alexander Extra - St. Louis - St. Louis - 3t. Louis Anniston - Columbia - Anniston - Anniston - Anniston - Plant B - .ainiston - Anniston This is Copy No. 10 MCNS 060031 INDEX Page No. A. General Characteristics ofAroclor 1254- .... Hazards ......................................... Precautions inHandling ........................... 1 2 2 B. Storage Tanka and Handling Eouip- ment .................................................................... 2, 3 C. Tank Cars, Their Unloading, Return, Efte........................................................................ A APPENDIX MONS 060032 a. ggniiAL Characteristics of Aroolor 1254 Foot: Yellow tinted vlsoous oil. Color: a.F.H.A. 150 maximum. Acidity: (1,'gm. KOH per gram) 0.01 maximum Coefficient of Expansion: 0.000661 oo/co/deg.C. (25 deg. - 65 deg.C) 0.000367 ec/ec/deg.F. (77 " -149 yj Density - Specific Gravity 25'deg./25 deg.C : 1.538 to 1.54.8 1.48 at 80 deg. 0 Pounds per Gallon: 1.40 at 160 " 0 2.83 at 25 deg, C. Distillation Ranee - A5H>D-20 l!od: 365 deg. -390 deg. C 689 - 734 " F Evaporation Loss - A3Tt:-D-6 ICod: 163 deg.C. - 5 hrs. - 1.06 to 1,28$ 100 " C 6 n - 0.4/jmaximum. Flash Point: None Fire Point: Nona Pour Point: S deg. to 12 deg. C. 46 " to 54 " F. Viscosity - Saybolt Universal Seconda (ASUJ-D-e8) 210 deg. F (96.0 deg. C) 43.5 - 48.5 130 " F (54.4 " C) 260 - 400 100 " F (37.8 " C) leoo - 3800 Thermal Conductivity: 0.22 cal./ga./deg.C. at 0 deg. C 0.365 " /gc./deg.C. at 100 deg. C. Vapor Pressure: 7 mm.Hg. at 200 deg. C. 80 mm.Hg. at 275 " C. 520 nan Jig. at 350 " -C. Solubility: Insoluble in water. Readily soluble in moot organic solvents. Slightly soluble in the cornon alcohols. Resistivity: 100 x 10^ at 100 deg. C. minimum. (Ohm 0a.) Dleleotrlo Constant: 4.15 -4.35 at 100 deg. C. Refractive Index: 1.6370 to 1.6390 at 25 deg. C. HONS 060033 -2- Hazarda The fumes from. Axoelor 1254 are quite obnoxious and are, whan inhaled excessively, dangerous and hazardous. When handling this material in relatively closed areus, ample ventilation (hoods in ex treme oases) should be provided for removal of the fumes from the working area. The fumes attack the mucous membranes of the nasal passages and Irritation of the membranes and slight lung congestion may result from excessive inhalation of the fumes. The handling of Aroclor is carried out at temperatures ranging from 75 deg. C. to 130 deg. C.. thus presenting a minor hazard of burns resulting from contact v.ith the hot liquid. Such burns require no special treatment. Precautions la Handling Aroclor 1254 will readily absorb traces of moisture. It Is essential that the material be kept from contact with water. All air coming in contact v.ith the Aroclor 3hould be properly dried by passing through a dehumidlfylng unit such as a calcium chloride breuther. activated alumina breather, or other similar dehydrating agent units. Calcium chloride breathers on all storage and handling tanks have been found to be completely satisfactory. B. STOP ACE TAI.KS ,J'D IlAirPIim lA.UIPCTT Although Aroclor 1254 is but slightly corrosive to metals, it promotes corrosion(by oxidation) of iron and steel. Hence, no handl ing equipment should be of steel construction where it comos in con tact with Aroclor. All prooesa piping handling Aroclor must be galvanized. All wetted pump parts must be either stainless steel or bronze. (Worthington '"orthite pumps have been found to be ccmplotely satisfactory for thi3 service.) Storage and handling tanks nay be of steel construction if properly metallized with zinc,-tin, or aluminum on the interior sur faces coming in contact v.ith the Aroolor. The netalllzing should he done aeoording to the following procedure: 1. Clean an area of the surface by sandblasting, or a similar method, to give a perfectly clean and roughened surface. The area oleaned should not be greater than can be com pletely metallized within a few hours after cleaning. MOWS 060034 -3 2. If zinc - tin metallizing la used, a ooatlnc of zino 0.005 Inches thlolc should be sprayed on the cleaned surfaoe. Thla la followed Immediately by a ooatlnc of tin 0.007 Inches think. 3. Metallization with aluminum has been found acceptable. All storage and handling tank3 should be amply provided with deliuaidifying breathers such as calcium chloride, activated alumina, eto. units. This is essential in order to prevent moist air from coming in contact with the .vroclor. A moisture content above 35 p.p.m. adversely affects the dielectric constant and the resistivity of the Aroelor. Storage tanks must bo provided with ample hoatlng coil surface to supply sufficient heat to the material to bring It to the proper tomporuturo for pumping, etc. Heating coils should be either metallized steel, or, profsrably, steel colls which have been gal vanized after fabrication. It is recommended that the steum pressure on all heating coils should not exceed 100 pounds per square inch gage; lower pressures should be used where practicable. It is essential that all steam coil3 be completely free of even minute leaks, since this would introduce water into the Aroolor. Before a newly constructed storage tank is filled with Aroolor, it should be heated to a temperature of at least 100 deg. C. to expel the moist air. The new tank should bo dried as much as is possible before charging. It would be beneficial to heat the tank, allow it to cool and pull in dry air through the dehumldlfylng breather, heat again, etc., until the tank is full of comparatively dry air befors the initial filling of the tank is started. Aroolor 1254 must be heated to 75 deg. C to 90 deg. C. for pump ing or other transportation through pipe lines, etc. When extremely rapid handling is desired, it is permissible to heat ths material up to 130 deg. C. It is not advisable to hold the material at such temperatures over extended periods of time, however. All handling pipe lines must be traced with steam lines and in sulation applied over the two lines in order to keep the handling lines and the material up to the desired pumping temperature. HONS 060C35 c. TASK CiJiS. TKTIH UWLO,PITO. JUITTTRJf. ETC. Aroclor 1254 Is shipped In two types of tank cars, both of which are either aluminum lined or zino - tin notalllzed. One type of tank has the heating ooila Inside the tank which are in dlreot contact with the Aroolor. The other type of tank i a double shell tank with heating ooila between the inner and outer shells. Doth types of tank are tested for 60 pounds pressure and their steam oolls are tested for 200 pounds. Beforo unloading the Aroolor, it is necessary to bring it to pumping temperature in the tank car. The steam coll outlet nay be either trapped or throttled with a valve. It is reoonrended thet steam pressures be limited to 100 pounds, particularly in the case of the coils being in direct oontaet with the Aroolor. It will require from 6 hours to 12 hours to bring the material to pumping temperature (75 deg. C. to 130 deg. C.J. depending on weather conditions. After the tank car is emptied, the steam coils must be blown clear of water end properly capped. Aroclor 1254 must be unloaded by displacement with dry airi There are either two or three connections on the tank oar dome, de pending on the car type. iThen three connections are found, there la one 2 inoh unloading connection which extends to the bottom of the tank, one 1 inch air inlet connection, and one pressure safety vent which is adjusted to release any pressure in exoess of 60 pounds. The vent connection is hooded for protection. V'hen only two connections are found, one is a 2 inch unloading connection and the other is the safety vent. In this case, it is necessary to re move the safety vent and introduce tho displacement air through that connection. V'hen unloading is complete, all connections must be replaced as received. It is requested that the empty tank be sealed immediately aftor tho connections are broken in order to keep the tanks filled with dry air during return shipment. It is essential that the displacement air used for unloading he thoroughly dried by scmedehumidifylng unit such as a oalolui chloride, activated alumina, or similar dehydrating agent drying unit. Required air pressures for unloading will depend upon the lay out of the unloading system. An unloading dock with proper piping connections should be pro vided at the railroad track vhere the Aroclor is to be unloaded. This dook should be provided with the connection to the discharge piping, the displacement air piping, and suitable steam connections for use on the steam colls. HONS 060036 APmmx VDDITXOIT.g. IUOraiiTIOtl COHCERUIMQ Wffi H.JlDIItr, ort^tOCIOR 12 S4 Attached to this copy of this report is ronsanto Chemical Company, Phosphate Division. Drawing ho. 9C-6170-5 showing the detail construction of a 15,000 gallon storage tank for Aioclcr 1254. This construction hiis bean found to he ocmpletely satis factory and Is, to the beet of our knowledge, the beat con struction for this service. The various nozzles on this tank are used as folia', s, con sidering them in order from left to right on the drawing: 3" nozzle 24." nozzle 3" nozzlo 36" manhole 3" nozzle 24" nozzle 3" nozzle 3" nozzle 1S"x26" Oval nozzle 3" nozzle Inlet for recirculation. For rutur* agitator If required (not used). For oalolur. chloride breather connection. For inspection, eto. Flont gauge located In center of this manhole. ITot used. For future agitator If required (not uaed). Tot used. Filling Inlet oonneotlon. For sump pump. For thermometer well (see detail). The two 24" nozzles r/ere originally Installed for Installation of agitators if required, rov;ever, it has been found anneeeasary to use agitators In the storage tank, and these nozzles could be omitted from storage tanks whero extreme agitation Is not required. It has been found that circulation of the Aroolor by the sump pump, and Into the nozzle on the opposite end of the tenk, for several hours gives satisfactory blending of the tack oontente. For pumping Aroclor 1254 from the storage tank, a Taber Tump Company all bronze 2-1/2" x 2" vertloal pump (Figure 1940) with monel shaft haa been found to be quite satisfactory for the applloatlon. Further details and speoif1cations for this pump will be furnished on request. HONS 060037 APFSTDIX P.2 Til* liquid level gauge used In the storage must be gas tight. The Monsanto Aroolor 1254 storage tanks are equipped v.lth Vapor Recovery Systems Co. "Varec", Fig. 253 gas tight automatic tank gauge. Further details and specifications for this level Indica tor will be furnished on reruest. It 13 recorcmonded that the stcrred Aroclor be filtered through a filter press using paper before using in order to remove any foreign matter such as scale, etc. Details of a suitable filter oan be furnished on reruest. The storage tank should be- provided, with an operating platform suitable to the customers conditions of operation. A dook for unloading should be provided at the tank car unload ing looatlon. This dock oan be constructed to oonfora to other loading or unloading dooks used by the customer. Detail prints of loading dooks used by Monsanto will be furnished on request. The dehumidlfylng unit used as a breather on the storage tank oan ba of any suitable construction. Calcium chlorlda breathers constructed as shown on Monsanto Chemical Company, Phosphute Division Drawing Mo. 9C-824.E (attached) have been found satisfactory. The upper portion of the chamber is charged v lth anhydrous aulolum chloride. Periodic inspection of the calcium chloride will show the formation of a cake of damp material on top about 1 to 1 1/2" deep. This cake should be removed and fresh material reehargod. Any suitable construction similar to that shown on Drawing No. 9C-8248 may bo used for the breather units. "TA:mz HONS 060038