Document QXp2GERQm3ere4RQeD2zJDqZo
FROM
MARIO GARZA, JR
TO GARY GRIESBACH
January 18, 1988
REj.___Bldgi_81 _Cafe ter ia_Asbestoa_ Air _Samgle_ Results
During the recent asbestos removal project in the cafeteria, part of the job included taking air sample tests as required by law during a job such as this. The results of the air sample tests are attached to this letter for your review.
The samples were taken (PowerMaster Inc.) and Services for analysis. NIOSH method #7400.
by the asbestos removal contractor submitted to Mckee Environmental Health
The tests performed were done using the
If you have any questions or concerns please contact me at ext. 727. If any further action is required also please let me know.
Mario Garza, Jr.
77/^
Mechanical Wvg/neering
copies to: W.T. Eckert J.M. Mitchell E.B. Parker Jim Richter J.J. LaClair
ARD 003935
D
received J/'.;-; 7 E3?
McKEE ENVIRONMENTAL HEALTH SERVICES
11114 SuKC|)urk 1 lousion. TX 77089 (718)481-8501
December 27, 1987
LAB ANALYSIS REPORT
Client:
Power Master, Inc. P.O. Box 778 Deer Park, Tx 77536 Attn. Richard Waters
Project:
Alcoa - Rockdale, Tx (Cafeteria)
Test Performed:
NIOSH Method #7400 Fiber Counts (Asbestos) Field Size: 0.00785 mm2
Sample
Worker 6/or
Total
Volume
NumberLocation(min)(liters)
Fibers per cc
12/23/87 baseline-before removal
256-A -1
blank filter = LT 0.64 f/mm2 backroom by loading 60 dock
1508
LT 0.001
-2 mechanical room
55
-3 behind serving line 53 under return air grill
1370 1173
LT 0.001 0.001
-4 dishwashing area in 71 kitchen
1136
0.003
-5
air handling area
65
1146
LT 0.001
note: 12" circulating fan used to stimulate normal activity
Ronald S. McKee Certified Industrial Hygienist
A.I.H.A. ACCREDITED LABORATORY
ARD 003936
AIR SAMPLE ANALYSIS RESULTS POWER MASTER INCORPORATED DEER PARK, TEXAS
LOFLIN ENVIRONMENTAL SERVICES (SAMPLES DELIVERED BY CLIENT)
PROJECT NUMBER J0049-88A
DATE: JANUARY 7, 1988
SAMPLE DATE
SAMPLE LOCATION (ACTIVITY)
SAMPLE FIBER VOLUME CONCENTRATION (liters) (fibers/cc)
12-27-87 BOILER (0700-1000)
BOILER (1000-1700)
12-28-87 BOILER (1400-1900)
12-29-87 BOILER - CLEARANCE (0700-1000)
BOILER - CLEARANCE (1000-1400)
12-28-87 CEILING (1200-1830)
CEILING (0700-1200)
12-27-87 KITCHEN (0700-1700)
12-29-87 KITCHEN - CLEARANCE (1400-1600)
KITCHEN - CLEARANCE (1400-1800)
450 SAMPLE OCCLUDED
1050 SAMPLE OCCLUDED
750 0.05
450 0.01
600 0.01
975 0.15
600 0.05
1500
0.02
300 0.08
600 0.01
Fibers per cubio-centimeter of air as determined using the NI0SH-7400 method. This method counts all airborne fibers of a specific size and shape. It is not specific for asbestos fibers nor does it include airborne fibers in all sizes.
1 ARD 003937