Document QXJ6bk7we29rn2gQLNvZ5vj64

UNDERWRITERS LABORATORIES INC. _ FACTORY INSPECTION PROCEDURE Subj. 758 Vol. Section 5 Page S036 This Page Effective Issued: May 1, 1959 Revised: July 1, 1980 Style 5036 Asbestos-Insulated Wire, Style AF Rating 150 C, 300 volts. Conductor No. 18-10 AWG, same as for Type AF wire, monel, nickel, and nickel-clad copper. Insulation Same as for Type AF wire. Covering Same as for Type AF wire. - Standard Flexible Cord and Fixture Wire. Instructions Same as for Type AF wire. to Inspector Northbrook Counter-Check Program (4) Same as for Type AF wire. *(4) Flexibility, Page 48. Marking General, Page 13, with the addition of the following information: 1. For use on appliances and devices manufactured by (see facing page for name of manufacturer) 2. Style AF. if Use Internal wiring of heating appliances. 0046