Document QXEwROEr5XeL7VQpbQ15xaeaE

370 Heating System* Bamn, c< The Sonner Burner Company DESIGNERS AND MANUFACTURERS OF GAS CONVERSION BURNERS OFFICES AND FACTORIES : WINFIELD KANSAS Sooner Gas Conversion Burners are a product of nearly a half century of specialisation in ........i.d....m.. .a..n..u..f.a..c..ture. Man.y of the Sonner Conversion Units feature the Blue Ribbon Flame LV Burner Head with Airblend Design. Bach ribbon of flame receives all the oxygen it needs to support complete effective combustion--from both sides along its full length--because the extraordinary Sonner Airblend Design provides just the right amount of secondary air in the right places. Catalog 5S-L-S gives complete description of this efficient blue ribbon of flame. A wide range of designs provides a Sonner Burner for do mestic, commercial, or industrial use. Sonner engineering serv ice is always available for consultation; write for catalog con taining complete line. Type LVS Step-Fire Burner assemblies for large heating plants power boilers where load varies to such extremes as to make this operation desirable. Three step control is the usual arrangement although it may be altered to meet epgi- icmcations. Standard assemblies using the Sonner Blue Ribbon Flame LV Burner head with airblend design which provides just the right amount of secondary air to support complete and effective combustion, capacities for 1,440,000 to 7200,000 Btu/hr are described in Catalog 57-LVS-l. Larger ca pacities available; consult Sonner engineering service. Type L-l Heat is designed specifically for the con version of residential heating-plants, either round warm air furnace or a rectangular boiler, to gas. Completely automatic burner, nging the Blue Ribbon Flame LV Burner head with air blend Hftwign, is A.GA. listed. Available in two rises with ca pacities ranging from 75,000 to 400,000 Btu/hr. See Catalog 68-L-t. Type WX-55 Sonner Burner specifically d< ied for re placing small gun type oil burners in domestic furnaces and joilera. A__._G__A_. .li.s. ted with inputs ranging from 75,000 to 200,000 Btu/hr. S"ee C`atalog WX-55-1. Type R Sonner Burner with horizontal flame for conversion of scotch marine boilers and similar equipment to gas and stand-by fuel applications. A multiple-venturi burner in fac tory built fully assembled form. Standard assemblies from 240,000 to 7300,000 Btu/hr. See Catalog 58-R-l. Larger capaci ties available; consult Sonner engineering service. Gas-Oil Unit for commercial and industrial boilers, two fuel burning'unite, each designed for one fuel only--natural gas light fuel oils. For capacities 'from 280,000 to 2,800,000 Btu/hr input; See Catalog 6t~GXJ-l. Larger capacities avail able; consult Sonner Engineering Service. Heating Systems . Bnm. op 37! THE CARLIN COMPANY 912 SILAS DEANE HIGHWAY . WETHERSFIELD 9, CONN MANUFACTURERS OF OIL BURNERS AND OIL-FIRED HOT WATER HEATERS Pressure-atomizing, fully automatic, gun-type Oil Burners for residential and commercial in* stallations. The Carlin Company manufactures a complete line of quality oil burners in capacities from 0.65 to 20.00 gph for use of No. 2 grade fuel oil. Pedestal and flange mounted models are offered. Suspension mounting to popular makes of boilers and furnaces is made easy with a wiae selection of flanges and mounting filates especially developed by U.S.-Carlin. Advanced design eatures include the "Shell Head," a significant improvement in oil burning which develops higher combustion temperatures, makes heat-wasting soot deposits negligible, conserves fuel. With either distiuate or catalytic fuels, operation is quiet, clean, economical. Generous use of heat and corrosion resistant alloys guards against deterioration--makes cleaning easier. U.S.-Carlin Oil Burners are available with Electronic Controls which comply fully with Underwriters* Labora tories latest safety switch timing requirements. Many types are factory mounted and wired to insure proper hook-up and save on-the-job wiring expense. For complete technical literature including consulting en gineers' manual, specification sheets, electronic control data, combustion chamber dimensions, etc., address The Carlin Go., 912 Silas Deane Highway, Wethersfield 9, Conn. CONDENSED SPECIFICATIONS MOTOR--Long-hour duty with safety overload control. Complies with NBMA mounting specifications. hp. (Models 400,150F, 400S, 150SF-2, 500S-35); % hp. (Models 650, 700S-35, 8008-4); y* hp. (Model 1200); H hp. (Models 2000S-5, 2000). TRANSFORMER--Shielded to block radio and TV inter ference. 10,000 volt (12,000 volt on Models 2000S-5,1200, 2000). AIR TUBE--Steel with beat resistant air cone. FAN--Precision balanced. Mounted directly on motor shaft. NOZZLE--Stainless steel alloy. Hollow cone spray (Hollow cone or solid spray on Models 1200, 2000). Dual nozzles on Models 500S-35, 650, 700S-35, 80OS-4, 2000S-5, 1200, 2000. FUEL UNIT--Single-stage standard on Models 400, 150F, 400S, I50SF-2, 500S-35, 650. Two-stage on Models 700S-35. 800S-4, 2000S-5, 1200, 2000. Built-in strainer and pressure regulating valve. Capacity of strainer equals or exceeds maxi mum firing rate of burner. SOLENOID VALVE--Combination delayed-opening and in stantaneous cut-off oil valve standard on all "S" models, also 1200, 2000. COMBUSTION HEAD--Models 150F, 400, and 650 have standard head with diffuser vanes formed at a fixed angle to establish air pattern. Model I5QF (0.65 to 135 gph capacity) and Model 400 (0.65 to 1.00 gph capacity) have a series of ad justable openings in center of diffuser for regulating air de livery to shape the fire. All "S" Models have "Shell Head" and finned collar for efficient mixture of air with oil. Models 1200, 2000 have High Temperature Combustion Head with finned collar for greater firing rate (Model 2000) and narrower fire. --ELECTRODES'--Nichrome steel with full-glazed.porcelain insulators counterbored for utmost safety. Flared, "Wide-arc" design permits heavier spark and assures positive protection during low voltage periods. BUS BARS--Rigid heavy-gage brass (Models 400, 400S, 500S35,700S-35,8008-4); phosphor bronze (Models 150F and 150SF2); high tension leads (Models 650, 2000S-S, 1200, 2000). HOUSING--Cast iron. Designed to assure efficient air de-livery and quiet operation. Machined to rigid standards. COUPLING-jUniversal type with neoprene center piece. (Flexible typeon Models 20008-5,1200, 2000). CONTROLS--Thermostat, Limit Control, and Stack Relay. Electronic Control set in place of Stack Relay on Models 8008-4, 2000S-5, 1200 and 2000. ELECTRICAL CHARACTERISTICS--115V-60 cycle. 1725 rpm. All models except 15QF and 150SF-2 available with230V-60 cycleonspeclal order. Also a complete line of 110 and 220V-50 cycle models with capacities from 0.50 to 15.00 gph. MODEL 400 0.55 to 4.00 gph Also available for flange mounting MODEL 400S 0.75 to 3.00 gph Also available for flange mounting MODEL 150F 0.55 to 2.00 gph Also available for pedestal mounting MODEL 150SF-2 0.65 to 1.35 gph Also available for pedestal mounting MODEL 500S-35 3.00 to 4.50 gph MODEL 700S-35 3.50 to 7.00 gph MODEL 650 3.50 to 6.50 gph MODEL 800S-4 4.00 to 8.00 gph MODEL 1200 MODEL 2000S-5, 7.00 to 12.00 gph 6.00 to 12.00 gph MODEL 2000, 10.00 to 20.00 gph tLS.-Carlin Oil Buraen are listed by Uvienm-iteri' Laborrt&im. Ime. and are approved under U. 8. Governnroi Commercial Standard CS7SU. Grade of fuel ofl recommended ia No. 3 U. S. Government Com mercial Standard CStt.