Document QX8p6wgnR4BMVmK268KjDk3Xo

Keloinalor Corp. Air Conditioning and Automatic Heating Down-Draft Duct Coil _ DS DOWN-DRAFT DUCT COILS A complete line of Down-Draft Coils are available for installation in existing ventilating and air washing systems to convert such systems to summer air conditioning and cooling. These coils are also applicable to new central station plants. Coils are offered in nominal tube lengths of 20 in., 29 in., 36 in., and 48 in. with capacities per coil ranging from 1 to 10 tons, and multiple arrangements of coils for any desired capacity. The down-draft fea ture of this coil insures immediate drainage of the condensate formed in dehumidification, and uniform distri bution of refrigerant and maximum capacity of the coil. CONDENSING UNITS Kelvinator offers a complete line of air cooled and water cooled Condensing units, ranging in the air-cooled series from K H. P. to 5 H. P., and in the water-cooled units from H. P. to 20 H. P. In its more than 21 years of refrigeration engineering and research, Kelvinator has developed condensing unit design and con struction which is of highest quality, in conformity with the best engineering practice, and each unit has been specially devised for the particular requirements of its job. CONDENSING UNITS--SPECIFICATIONS--AIR COOLED MODELS Model No. B625 G633 H650 F675 K6I00 R6I50 Y6200 T6300 T6500 H.P. V* H Y%l 1V2 2 3 5 No. of Cycles 2 2 2 2 2 2 2 2 2 Comp. R.P.M. Refrigeration Capacity Tons per 24 Hours* 415 0.24 315 0.32 340 0.46 330 0.70 310 0.96 310 1.33 280 1.92 260 3.08 375 4.12 Overall Dimensions (Inches) Width Depth Height 25 25% 28 3oy. 35% 40 40 44 44 \ 17% 17% 19% 23% 24 26% 28% 27% 29% 18% 1916 19% 21% 23% 26% 27(4 29% 29% Approx. Net Weight Pounds 148 183 215 366 408 537 617 750 850 WATER COOLED MODELS WB625 WG633 .. WH650 ; WF675 WK6I00 WR6150 WY6200 ` WT6300 WT6500 WU6750 WU6100Q WV61500 ' WV62000 '4 H Vz V4 1 i% 2 3 5 71/2 10 15 20 . 2 - . 465 2 - 365 2 410 2 400 2 400 2 400 2 375 2 300 2 440 2 440 2 650 4 440 4 650 0.30 0.40 0.59 0.85 1.36 1.88 2.55 3.27 4.80 7.00 9.95 . 14.00 19.90 2534 14% 2534 . '4% 29 15% 30% 19% 35 19% 40% . 22% 40% 22% 44% 23% m55% 72% 72% 23% 92% 28Vb 93% 31 18% 19(4 1934 21% 22% 26% 27% SR 34% 43% 4334 46 169 195 200 380 413 511 605 835 1200 1960 2035 3095 2185 ^Approximate one point rating capacity-based on 80 F. Condenser Water Temperature or 90 F. Con denser Air with 37 lb Average Suction Pressure. Consult Dealers for Exact Selection. 810 Kelvinator Corp. Air Conditioning and Automatic Heating KELVINATOR AUTOMATIC HEATING BOILER BURNER UNITS (STEEL) Kelvinator Boiler-Burner Unit offers the heating engineer a compact unit built of welded steel and thoroughly insulated. Exterior metal jacket is rust-proofed, finished with light gray lacquer and trimmed in polished chromium. Outstanding boiler features are cylindrical combustion chamber, single pass tube bank, spiral baffles and thorough insulation. Boiler Burner (Steel) Model No. KB-1 BOILER BURNER UNITS (CAST IRON) Exceptionally compact and attractive in ap pearance, these units provide an unusually efficient sectional cast iron, oil burning boiler, a domestic water heater and oil burner assembled as one unit inclosed in an attractive bonderized steel jacket trimmed with chromium. Moulded combustion chambers, conforming to the natural size and shape of the flame, quickly develop the maximum amount of heat contained in the fuel. The sectional design permits easy installation without altering stairways or doors. BOILER'BURNER UNITS--110 V.--60 CYC. Model No. Fuel Oil Capacity per Hour Square Feet Radiation Steam Hot Water KBI (Steel) KB2 (Steel) KB3 (Cast Iron) KB4 (Cast Iron) KB5 (Cast Iron) 1.22 Gal. 2.00 GaL 1.66 Gal. 2.6 Gal 3.5 Gal. 565 925 780 1230 1635 850 1400 1170 1845 2450 Steel units have constant electric ignition and line voltage controls. Cast Iron units have intermittent electric ignition, low voltage A. C. controls for 115 V. D. C.. line voltage 115 V. D. C. controls. CONVERSION TYPE UNITS Model No. Fuel Oil Capacity Gallons per Hour 110 V.. 60Cyc.. 115 V. D. C. 110 V.. 25 or 50 Cyc. Square Feet Steam Radiation 110 V.. 60 Cyc., 115 V. D. C. 110 V.. 25 Cyc. or 50 Cyc. K-1 2.5 2.00 750 550 IC-IA 2.0 1.75 600 500 K-2 4.5 4.25 1300 1200 K-3 7.5 6.50 2200 1900 Intermittent electric ignition low voltage A. C. controls, line voltage D. C. controls. All Units Have: Split Phase Motor; Pressure Fuel Atomization; and require AOBA No. 120 D3 Fuel Oil. CONVERSION TYPE UNIT- MODEL No. K-l Kelvinator Conversion Type Pressure Burner Units for conversion of existing heating plants feature advanced design for long life, economy and trouble-free heating sendee. Features are: fuel control unit, noiseless, self - priming, non - pulsating pump, adjustable air shutter, scientific fan and housing construction for noiseless operation, directly connected motor with overload protection, air turbulator for complete combustion. These and other features indicate the thoroughness with which Kelvinator adheres to the best engineering practice. 811