Document QX22o2N144j0zpX7JeR4v7zp5

Industrial Hygiene tected by installing a ventilation system which probably would not have been satis factory if the operation had not been iso lated and thus able to be enclosed Enclosing the process or equipment is a desirable method of control since the en closure will prevent or minimize the escape of solvent vapor into the workroom atmos phere Where some ol the more highly toxic solvents are used, enclosure should be one of the first measures attempted, after con sidering substitution In most instances, the enclosure should also be exhausted to avoid buildup of solvent vapors Additional pre cautions must be taken when cleaning en closed equipment or during start up or shut down in order to avoid high concentrations of solvent vapors Enclosure of an operation effectively pre vents the dispersal of contaminants En closed equipment is usually run tightly closed and is only opened during cleaning or fill ing operations Further examples of where this tvpe of control is effective are radium dial painting, glove booths, airless blast or shot blast machines for cleaning castings, and abrasive blasting cabinets In the chemical industry, the isolation of hazardous processes in closed systems is a widespread practice, which is one reason why the manufacture of toxic substances is often less hazardous than their use In the mechanical industries, complete enclosure is Irequently the best solution of severe dust or fume hazards, such as those from sand blasting or metal spraying operations Wet methods Dust hazards can frequently be minimized or greatlv reduced bv application of water or other suitable liquid at the source of dust, a method often used for silica and loose dusts Wetting of floors before sweeping to keep down the dispersion of harmful dust is ad visable when better methods, such as vacuum cleaning, cannot be applied "Wetting down" is one of the simplest methods for dust control Its effectiveness, however, depends upon proper wetting of the dust This may require the addition of a wetting agent to the water and proper dis posal of the wetted dust before it dnes out and is redispersed Tremendous reductions in dust concentrations have been achieved by the use of water forced through the drill bits used in rock drilling operations Many foundries successfully use water under high pressure for cleaning castings in place of sandblasting Airborne dust concentrations can be kept down if molding sand is kept moist, if castings are wet down before shake out, and if the floors are wetted nitermittentlv Local exhaust ventilation A local exhaust system traps the air con taminant near its source so that a worker standing at the process is not exposed to harmful concentrations This method is usually preferred to general ventilation, but should be used onlv when the contaminant cannot be controlled by substitution, chang ing the process, or isolation or enclosure Even though a process has been isolated, it may still require a local exhaust system After the system is installed and set in op eration, its performance should be checked to see it meets engineering specifications -- correct rates of air flow, duct velocities, nega tive pressures, etc Its performance should be rechecked periodically as a maintenance measure Full details of this method of control are given in Chapter 29, "Local Exhaust Sys tems " For further reference, see NSC Industrial Data Sheet 428, Checking Per formance of Local Exhaust Systems General or dilution ventilation General or dilution ventilation --adding air to keep the concentration of a contami nant below hazardous levels --uses natural convection through open doors or windows, roof ventilators, and chimneys, or artificial air currents produced by fans or blowers Exhaust fans through roofs, walls, or win dows constitutes positive all season dilution ventilation Consideration must be given to providing make-up air, especially during winter months Dilution ventilation is practicable onlv if the degree of air contami nation is not excessive and particularly if the contaminant is teleased at a substantial distance from the worker's breathing zone Under other conditions, the contaminated air will not be diluted sufficiently before inhalation General ventilation should not be used 1288