ARCO Marine, Inc.
Internal Correspondence
Date: Subject:
March 16, 1988 ASBESTOS INSPECTION/ARCO ANCHORAGE
JW
From/Location: David Sucharski To/Location: Master/ARCO ANCHORAbu
Enclosed please find four (4) copies of my memo describing the findings of the asbestos inspection of ARCO ANCHORAGE. Please post this memo on the ship's bulletin boards and take appropriate steps to ensure that it is brought to the crew's attention.
DBS:dd
cc: S. Factor Capt. R. W. Lawlor A. M. MacGillivray X. J. Padilla P. Persaud J. L. Sullivan
ARCO Marin*. Inc. I* a SubaMtary el AbantlcAlehflaldCompany
AMI-1-7-B (8-84)
ARCO Marine, Inc.
Internal Correspondence
Date: Subject:
March 16, 1988 ASBESTOS INSPECTION/ARCO ANCHORAGE
From/Location: David Sucharski
To/Location:
Master ARCO ANCHORAGE
The ARCO ANCHORAGE was surveyed for asbestos exposure by Dan Napier & Associates Industrial Hygiene on 14 January 1988. Both dust and air samples were taken. His report states:
"The bulk samples taken in the crew's quarters did not contain detectable levels of asbestos."
"The air monitoring samples were evaluated by optical microscopy (PLM) and electron microscopy (EM). The test results did not indicate any airborne fiber levels."
Because the ship has material which contains asbestos, mainly
the ceiling and bulkhead panels and some deck insulation, we
will continue to monitor for asbestos in the future and keep
you informed. Anyone who wishes further information should
contact the ARCO Transportation Industrial Hygienist,
Ms. Pamela Persaud (213-590-4465) or me (213-590-4527).
DBSrdd
ARCO Marin*, lne. ia Subsidiary of AflanUcRlchfWdComparry
AMM-7-B (8-84)
Dfln nflPI& & flSSOCIflTS
inDUSTttlflL HUGIn
DAN NAPIER, M.S., C.I.H., C.S.P. ROBIN ekroot, M.S.
Pamela Persaud ARCO MARINE TRANSPORTATION 300 Oceangate Long Beach, California
153*2 HAWTHORN E BOULEVARO, SUITE 207
LAuinDflie, cflufoonifl 90260-2105
telephone 2t3-B**-l02*
January 20, 1988
Dear Ms. Persaud;
This letter will confirm our meeting on January 14, 1988, at that time we reviewed your vessel the Arco Anchorage with David Sucharski. During the meeting we conducted an asbestos survey. The result of that meeting is summarized here, and specific results of laboratory findings are submitted on the attached form.
The bulk samples taken did not contain detectable levels of asbestos. The air monitoring samples were evaluated by optical microscopy (PLM) and electron microscopy (EM). The EM work has not been returned, and appropriate conclusions will be made as they are received.
The vessel is fire protected in the living quarters with a cement asbestos paneling. The paneling is cracked at the corners and indicates damage in areas that have been removed for normal shipboard maintenance and modification. The panels as such do not present a serious hazard unless the are made to be friable, through mechanical abrasion or fracturing. The study is not conclusive as the levels should be evaluated at a worst case situation. A worst case situation would be assumed during heavy sea conditions. Air monitoring conducted during winter sea conditions should serve to document the worst case situation. At this time there are no indications of an asbestos exposure related to occupancy on this vessel. We did observe that the dust and dirt levels were high and could obscure an effective air quality study.
The next meeting has not been scheduled, however should any questions arise please call me.
Respectfully Submitted
SURVEY SUMMARY
The following items are submitted for your approval and implementation. The test result is described and a recommended action is suggested. Safety is a responsibility of your management. Our work is intended to assist you. Recommendations are developed from conditions observed at the time of our visit. They do not necessarily include every possible loss potential, code violation, or exception to good practice. This report applies only to the sample, or samples, investigated and is not necessarily indicative of the quality or condition of apparently identical or similar products or conditions. As a mutual protection to clients, the public and us, this report is submitted and accepted for the exclusive use of the client to whom it is addressed and upon the condition that it is not to be used, in whole or in part, in any advertising or publicity matter without prior written authorization from us.
Exposure: Employees modify and drill the living quarters panels to fix decorations, devices etc to the wall and ceiling. These penetrations can create a asbestos fiber spill. Recommendation: Provide a guideline for any penetration, modification of the living quarters area;
Exposure: The panels sometimes fracture and old wall penetrations can flake off asbestos containing material. Recommendation: Provide HEPA Vacuum equipment for use on a daily basis to ensure that the asbestos material is not becoming entrained in the housekeeping equipment.
Exposure: The vessels contain asbestos panels that may become friable during the life of the ship. The sea conditions and the age of the vessel may tend to create an exposure condition. Recommendation: Conduct air monitoring onboard the vessel during a sea voyage in conditions that would deyelop a worst case situation.
Exposure: The vessels contain asbestos panels that may become friable during the life of the ship. The ship has several potential asbestos sources, gaskets, living Quarters wall and ceiling panels, and lagging that may have been overlooked during previous mitigation projects. Recommendation: Develop a management program to control and identify asbestos containing materials and provide a clear protocol to mitigate exposure. That is properly use, dispose of or control asbestos containing materials.
DAfl nAPIEfc & ASSOCIATES
inDUSTftlflL HUGIf1
OAN NAPIER, M.S..
C.S.P.
ROBIN EKROOT, M.S.
Sample Data Sheet
Fibers In Air
153*2 HAWTHORNE BOULEVARD, SUITE 207
Lfliunofli, cflufoanm 90260-2105
TELEPHONE 2l3-e*4-l92*
January 14, 1988
Sample Number: AT37361
Location of Study: Address:
Blank Control value
ARCO Marine, Inc. 300 Oceangate Long Beach, CA 90802-434
0.010
This blank correction has been averaged with other blanks and used to correct the submitted values
The microscopist was Faith V. Ujda The Industrial Hygienist was Pamela Persaud
Dfln flflPI& & ASSOCIATES inDusTiiiflL HVGiene
DAN NAPIER, M.S., C.I.H., C.S.P. ROBIN EKROOT, m.s.
Sample Data Sheet
Fibers In Air
*53*2 HAWTHORNE BOULEVARD, SUITE 207
LAUinOflLf, CAUFO&niA 90260-2105
TELEPHONE 213-C**-I92*
January 14, 1988
Sample Number: AT37362
Location of Study: Address:
Blank Control value
ARCO Marine, Inc. 300 Oceangate Long Beach, CA 90802-434
0.010
This blank correction has been averaged with other blanks and used to correct the submitted values
The microscopist was Faith V. Ujda The Industrial Hygienist was Pamela Persaud
Dfln nflP!B & ASSOCIATES tnOUSTKIAL HYGIfnE
DAN NAPIER, M.S.,
C.S.P.
ROBIN CKROOT, M.S.
Sample Data Sheet
Fibers In Air
IS3A2 HAWTHORN C BOUtCVARO, SUITE ^07
LflllinDflLE, CflLIFOBfllfl 90260-2105
TELEPHONE 2l3'6*l*td24
January 14, 1988
Sample Number: AT37363
Location of Study: Address:
Area of study:
ARCO Marine, Inc. 300 Oceangate Long Beach, CA 90802-4341
Fireman/water tender, upper deck (Anchorage)
This was a FIXED site study. The monitor was placed in a representative air parcel in the normal breathing zone.
NI0SH method # 7400 Revision 5/15/85 was used as the standard analytical procedure. A 25 millimeter cellulose ester filter 1.2 micron pore size was used as collection media. It was protected with a conductive cowl. A Nikon Phase Contrast Labophot Microscope with a Walton-Beckett graticule was used to analyze the filter media.
The personal breathing zone was monitored with a Wilrun 13081
A rotameter # 1
calibrated against a primary standard on 11/20/87
was used before and after the sample to estimate the air volume.
The sample was started at 8:40 hours. The starting flow rate was 11000 ml/min.
The test was stopped at 11:54 hours. The ending flow rate was 10500 ml/min.
The average flow rate was 10750.00 ml/minute. The total time was 194 minutes
the total volume was 2085.50 liters.
Analysis found a total of 0.095 fibers per field. Time Weighted Average of 0,002 fibers per cubic centimeter was extrapolated for the area. The quantification limit for this study is calculated at 0.002. The method (7400) indicates that the absolute limit is 0.01 fibers per cubic centimeter.
This analytical work was completed at Dan Napier & Associates. The microscopist was Faith V. Ujda. The Industrial Hygienist was Dan Napier MS, CIH.
The workers in the area were exposed to 1.1 percent of a daily allowed exposure.
The detection level. 0.002 is greater than the measured level. Since this information must be considered, the above calculations were based on the detecion level 0.00? f/cc and"not on the calculated level. 6.002 f/cc.
Dfln nflPIEfc & ASSOCIATES
inDUSTttlflL HUGIEF1E
OAN NAPIER. M.S.,
C.S.P.
ROBIN EKROOT, M.S. .
Sample Data Sheet
Fibers In Air
153+2 HAWTHORNE BOULEVARD, SUITE 207
uuunoflLE, cflufoanifl 90260-2105
TELEPHONE 2I3-B++-IB2+
January 14, 1988
Sample Number: AT37364
Location of Study: Address:
Area of study:
ARCO Marine, Inc. 300 Oceangate Long 8each, CA 90802-4341 Chief engineers office (Anchorage)
This was a FIXED site study. The monitor was placed in a representative air parcel in the normal breathing zone.
NIOSH method # 7400 Revision 5/15/85 was used as the standard analytical procedure. A 25 millimeter cellulose ester filter 1.2 micron pore size was used as collection media. It was protected with a conductive cowl. A Nikon Phase Contrast Labophot Microscope with a Walton-Beckett graticule was used to analyze the filter media.
The personal breathing zone was monitored with a
A rotameter # 1
calibrated against a primary standard on 11/20/87
was used before and after the sample to estimate the air volume.
The sample was started at 8:49 hours. The starting flow rate was 13000 ml/min.
The test was stopped at 11:19 hours. The ending flow rate was 12500 ml/mln.
The average flow rate was 12750.00 ml/minute. The total time was 150 minutes
the total volume was 1912.50 liters.
Analysis found a total of 0.170 fibers per field. Time Weighted Average of 0.004 fibers per cubic centimeter was extrapolated for the area. The quantification limit for this study
is calculated at 0.002. The method (7400) indicates that the absolute limit is 0.01 fibers per cubic centimeter.
This analytical work was completed at Dan Napier & Associates. The microscoplst was Faith V. Ujda. The Industrial Hygienist was Dan Napier MS, CIH.
The workers in the area were exposed to 2.1 percent of a daily allowed exposure.