Document QMX4n24eqVK5VaOMKyBaVDZMk
VOt_ 36. NO. 2
THE CHEMIST ANALYSE
SEPTEMBER. 1947
Summary
( ')
' -
Ferric chloride reagent is compared with cupric potassium chloride as a gravimetric reagent for sulfur. The advantages of ferric chloride are noted in the case of bronze and metallic copper. Possible use in the determination of the composition of non-ferrous furnace metals is mentioned.
X-ray diffraction patterns of the ferric chloride and the cupric potassium chloride residues show that sulfur remains as cuprous sulfide and elementary sulfur.
The procedure described has been in use for approximately one year and has given satisfactory results.
LITERATURE CITED
(1) American Society for Testing Materials, "X-Ray Diffraction Data for Chemical Analysis, Supplement."
(2) Holler, A. C., and Yeager, J. P,, Ind.Eng. Cltem., Anal.Ed., 16, 349 (1944). (3) Lundell, G. E. F., and Hoffman, J. I., "Outlines of Methods of Chemical Analysis," p. 218,
John Wiley & Sons, Inc., New York, 1938. (4) Cumenge, E., and Wimmer, R., Dingier: Polytech. J., 250, 85 (1883). (5) Silverman, Louis, Ind.Eng. Chem., Anal. Ed., 10, 433 (1938). (6) Weiser. H. B.. Milligan, W. O., and Marshall, J. M., J. Phys. Chem., 47, 496 (1943).
On the Toxicity of the "Arochlors"
ROBERT M. BROWN, Chief, Industrial Hygiene Section, Division of Health, Department of Public Welfare,
City of St. Louis, Missouri
A recently published article (/) has recommended the substitution of one of the "Arochlors" as the melting-point bath liquid in preference to the cus tomary sulfuric acid. As stated in that article, the "Arochlors" are a group of chlorinated diphenyls produced by the Monsanto Chemical Company.
There is need, therefore, to give a warning. For the toxicity of these compounds has been repeatedly demonstrated, both from the standpoint of their absorption from the inspired air as well as from their effect in producing a serious and disfiguring dermatitis when allowed to remain in contact with the skin. Since these effects have been repeatedly observed, industrial hygienists have taken great pains to see that proper controls have been estab lished wherever these products are used. For example, the maximum allowable concentration of chlorinated diphenyl for an 8-hour working day is I milligram per cubic meter of air.
It is probable that nothing like an uncontrolled industrial exposure will occur in the laboratory. However, whether an individual is subjected to a possible acute exposure to chlorinated diphenyl and its serious consequences will depend upon the size of the melting-point bath, the caution with which it is used and the temperature to which it may be heated. Likewise, with
Page Thirty-three
NOTICE- This P;'ct-ct2d by tsrial rnay be (-!. is -ly--(j;37 liEYLiZl JL/aiv_________ Led s)
^
THE-
CHEMIST -
ANALYST
-
--
*
September. 1947
.
careless handling of the material and the resulting contamination of the
skin, clothing, laboratory towels, work table surfaces, etc., the way if left
open for the producing of dermatitis. Scrupulous cleanliness must be insisted
upon wherever this material is handled.
.
The foregoing remarks have been prompted by the belief that, in recom mending the use of a material with which is associated a potential hazard from the health standpoint, it is very important that the possible consequence be presented together with recommendations for correct handling.
----------------------
LITERATURE CITED
(1) Maglio, M. Martin, Chemist Analyst, 35, 94 (1946).
Short Cut in Routine Water Analysis
MAXEY BROOKE Jefferson Lake Sulphur Company, Inc., Brazoria, Texas
The usual procedure in making routine water analyses, particularly of boiler salines, is to titrate a sample with sulfuric acid to the phenolphthalein end .point. The titration is then continued to the methyl orange end point. These measurements of the phenolphthalein and methyl orange alkalinities are generally expressed in grains of CaC03 per gallon.
To measure the salinity, a fresh sample of the water is first titrated with sulfuric acid to the phenolphthalein end point. Then a few drops of a 5% solution of potassium chromate are added and the sample is titrated with silver nitrate. The salinity is expressed as grains of NaCl per gallon.
When a large number of samples are to be analyzed, it would save time if
all three determinations could be run on the same sample. Since the chromate
acts as an indicator only through a narrow pW range, some means must be
used to increase the pW of the sample which has been acidified to the methyl
orange end point. To accomplish this, the potassium chromate is dissolved
in a 0.1 N sodium bicarbonate solution instead of the usual distilled water.
Five drops of this indicator solution are sufficient to bring the pY\ of the
sample within the desired range.
*
Duplicate tests were run with the buffered and unbuffered indicator. The results, expressed in grains per gallon, were as follows:
Sample
Neutral 0.390 N
Boiler saline Tap water
Methyl Orange Alkalinity CaC03
NaCl
0.0 23.1 55.0
Salinity NaCl
Unbuffered
1336 267
72
Salinity NaCl
Buffered
1336 267
72
Thus it will be seen that the short cut is fully as accurate as the standard method of analysis.
Page Thirty-five
vol. 35. no. 4
THE CHEMIST ANALYST
DECEMBER. 1946
..
slowly in an oven at low heat or by passing a small electric current through
it for some hours. The exposed plaster is then painted. When dry; it is
covered with water glass. The outside of the funnel may be protected as
desired.
This heater can be set up in a 5" ring. It will accommodate a 4" glass
funnel snugly, with only rim and tip protruding. The temperature require
ment for any given filtration is ascertained easily and accurately.- A filter
paper is folded, inserted in the funnel and moistened with a cool portion of the
solvent to be used in the filtration. The funnel is then covered with a clean,
cool watch glass and the current is switched on. When condensate begins to
appear on the watch glass, the funnel is ready for use and the current is turned
off. It is unnecessary to control the temperature thermostatically or by
means of the usual current controls. The appearance of the condensate is a
satisfactory temperature indicator.
____________
It is safe to use this technique with most hot organic liquids, because the
heating element is not exposed and the inside surface of the heater cannot
reach a temperature high enough to ignite inflammable vapors from the liquids
that are commonly used. Further, it is very convenient to use such a heater.
For the stem provides a heated zone between the receiving vessel and the tip .
of the filter cone. The possibility of crystallization in the residue on the filter
paper is minimized, for the paper is not exposed to the cooler air. The splash
ing of drops may thus be eliminated, since the tip of the funnel can touch the -
side of the receiver. Standard funnels may be used and do not have to be
shortened. If some crystallization should occur at the very tip of the stem,
it is concentrated in a small area and may be removed with a stirring rod, or
the funnel may be raised momentarily into the heater to effect re-solution of
the crystals. Besides, this apparatus is designed to heat up rapidly, attaining
an operating temperature of 100 C. in less than five minutes. It has good
heat capacity and keeps the temperature near the boiling point of the solvent
sufficiently long for most filtrations. Materials for its construction are gen
erally available. It is simple to construct and operate.
-
The author is grateful to Arthur T. Martin who helped in the design and
has constructed many heaters of this type for use in this laboratory.
.
A Safe Liquid for Melting-Point Baths
M. MARTIN MAGLIO Advance Solvents & Chemical Corporation, Jersey City, N. J.
In most laboratories it is customary to employ a bath of concentrated
sulfuric acid in making melting-point determinations. The use of this acid
is objectionable on account of the inherent danger. Of late some laboratories
have adopted one of the "Arochlors"* as a bath liquid. That these liquids
possess definite advantages over sulfuric acid is generally conceded. -
We have found that "HB-40,"* consisting mainly of a mixture of ter-
phenyls, is a very satisfactory liquid for melting-point baths, particularly where temperatures exceeding 300 C. are not desired. We heartily recom
mend its adoption.
-----------
Marketed by the Monsanto Chemical Company, 30 Rockefeller Plaza, New York City.
Page Ninety-four
.
. .1..
NOTICE- This mater ial may be
Protected'b (Title 17 U.
copyr\{ 't law Cede)
EX P-2890 Page 3 of 4
PCB-ARCH-EXT0381062
EX P-2890 Page 4 of 4
PCB-ARCH-EXT0381063