Document QMLE84YXrXKkr50eDjM9GbEe4
Industrial Hygiene Digest
April, 1964
in an essentially closed system. When tests, at or near the threshold concentration, indicated
that the sensitivity and reproducibility were essentially the same with and without the nose*
piece, it was discarded. Since polyethylene bottles often have a characteristic odor which
might interfere with threshold determinations, many methods of removing the odor and
cleaning the bottles were tried. The most satisfactory method found to date involves washing
thoroughly with a non.odorous detergent, rinsing carefully in boiled water, and boiling
the washed bottles in water 1.2 hours. Bottles made of teflon have now become available
and limited tests indicate that essentially the same results are obtained as with the
polyethylene bottles cleaned as above. Olfactory thresholds for a number of pure compounds,
several of which were identified in potatoes, indicated that, in general, sulfur compounds
and short.chained unsaturated aldehydes gave the lowest and highest thresholds, respectively.
The thresholds of a homologous series of saturated aliphatic aldehydes decreased progressively
with increase in chain length from Cj to Cio. Similar results were obtained with.a series of
unsaturated aldehydes. Thresholds of some of the more potent compounds were less than
0.1 of a part /10* parts of water.
-. APCA Absts.
390 Improved Techniques for Environmental Sample Analysis. A. L. Boni. Health Physics 9, 1035-1046 (Nov. 1963).
The need for reducing the handling and preparations of samples, and achieving
greater sensitivity and more specific data led to the development of improved analytical
techniques. When simplified sample preparation techniques are combined with gamma,
spectrometry using a large.well crystal detector, sample processing time is reduced,
lower detection limits are achieved, and more accurate specific analyses are obtained.
Sample collection preparation, field and laboratory equipment, and data processing are
discussed in detail.
__ APCA Absts.
391 Analysis of Toxic Gaseous Combustion Products. A. Fish, N.H. Franklin, andR.T. Pollard. J. Appl. Chem, (London) 13., 506.509 (Nov. 19^3).
A rapid and accurate gas chromatographic method of analysis of toxic gases
produced during the burning of solids containing chlorine has been developed. This technique
enables chlorine, hydrogen chloride, phosgene, carbon dioxide, and simple hydrocarbons
to be estimated from a single sample, a further sample affords determination of carbon
monoxide also. The method was applied to the combustion under a variety of conditions of
temperature, oxygen availability and reaction time of a fire-retardant building paper
containing approximately 20% of chlorine. Large quantities of carbon dioxide and hydrogen
chloride were produced, chlorine, carbon monoxide, and phosgene being minor products.
The results are compared with maximum permissible concentrations and their application
to actual fires is discussed.
-- APCA Absts.
392 Sulfate Particulates: Size Distribution in Pittsburgh Air. M. Corn and L. DeMaio Science 143, 803.804 (Feb. 21, 19&4).
Sulfate particles with diameters of less than 1.7 microns'contribute approximately
40% by weight to total sulfate particulate in Pittsburgh air. The irritant nature of these
particles and their small size and associated long atmospheric residence time, as well as
the short half-life of sulfur dioxide in the atmosphere, suggest that particulate sulfate may be
a better indicator of atmospheric pollution than sulfur dioxide.
-- Authors' abst.
393 Study of Air Pollution by Analysis of Particulate Material Collected from Air Filtration Plants. IV. Determination of Germanium in Total Air Solids. A.J. Lindsey and J.R. Stanbury. Intern. J. Air and Water Poll. 7, 1-3 (jan. 19<?3).
The method previously used was modified to suit germanium determinations in the ash from air solids collected from air filtration plants. The object of this investigation is to continue the study of total air solids, and the variation of the amounts of germanium is shown as
03121427
26.