Document QJxkp7gjLkq9wJnmKE4JYVQ8v
Monsanto
rn*M ihkmi l
Ml
I
UitCT
MUMNU <
TO :
0 wrjm osfSafiSr'
J. N. Maloney - Pensacola
Textiles Divisic
October 24 , 1969
cc
Monthly Report, October,1969, Analytical Development
C. R. Campbell
T. L. Broxton c. E. Cutchens R. H. Heidner R. E. W. E. Koerner J . A. Lubkowitz
j. F. McGuf fee W. M. Sheffield c. J . Webster T. H. Woltdr
Highlights
"Inline** blitzes In refined and blended HMD have been traced to diamine synthesis. They were caused by high levels of N-hexylszacycloheptane (HHMI)produced In crude HMD during a feed dis tribution test. Water samples from various locations In the plant and river have been analyzed for Arochlor 1254. This monitoring will continue on a weekly basis.
| Summary
HMD
Continued surveillance of crude HMD, using the new cyane extractlon-VPC procedure, showed high levels ( 300mpm) of HHM1
In 414B unit on September 24. Samples from other units at the same time analyzed less than 5 mpm HHMI. At this time a multiple feed injection test was being run on "B** unit while all other units were operating under standard conditions. Immediate term ination of the test unit prevented another "Inline" blitz In the refining system. Isolation and tentative Identification of Naminohexylazacycloheptane and higher molecular weight polyamlne homologs was carried out with crude HMD from this aborted test. The presence of these compounds, (at least 0.5%) supports the theory of poor reactanta mixing in the test unit.
-
I PCB Analysis
,
Thirteen samples have been analyzed shoving periodic releases of Arochlor 1254 from Bldg 406 Into the east ditch. The decanter of Bldg 408 contained 6.5 ppm Arochlor 1254. Slnce: this decanter sporadically overflows into the east ditch it explains the variable range observed. Samples are now analyzed on a weekly basis.
, Two electron capture detectors have been received and charac terized, for the analysis of Arochlor 1254 In aqueous streams. The ttltlunf detector was found to be more versatile in the analysis than the Nickel-63 detector since it showed greater linear range and greater sensitivity.
IN.I NIV, I
MONS 097083
Maloney to Campbell - Monthly October 24, 1969
Sample Load September 16, through October 15.
Project:
' No. Samples:
Chemical Support: HMD Pensacola
NAOC EHD Catholyte
PXD PCB HMI Conversion (W.A.Heckle) DBA Evaporator (J.J.Hicks) ADN,, ACN,Caprolactam
111 3
19 21 13 30 12
1 210
-2-
Nvlon Salt
The ifluorescence spectra of nylon salt that meet s plant specifications reveals two*regions of emission. The primary fluorescence occurs at 365 mu.- trhen excited with 295 mu energy. Data obtained to date Indicate that the fluorescence impurities come from HMD*
The fluorescence of nylon salt crystallized In the pilot plant was reduced from 0.98ppm to 0.06ppm as quinine sulfate. Other preliminary data show that, pH will be 7.74 and all routine measured Impurities will be reduced by 2 to 10-fold.
MQNS 097084