St. Louis - General Offices August 17, 1962 CONOOLEUM-NAIRN, INC.
Jf. H. Hunt ^ /T. Holllngs - N.a.
J. D. Wright - N.Y.
Mr. J, t. Lonsberg New York
Sam T. Martin of the subject company asked our comments on the incorporation of an Aroclor in an experimental foam formulation. The vinyl foam would be processed at 375F-400F. The product would be processed in an air inpingement oven
which does not have an air tight exhaust system. They wanted to know our comments on the inherent toxicity of Aroclor under these conditions.
The first comment would be is that we would have to determine which Aroclor they were considering in their foam formulation. If it is a product like Aroclor 5^60, I don't feel they would have a serious problem. We know that products like Aroclor 1262 are being used in similar type appli cations. The real problem, I think, is how tight is their oven? What type of exhaust system do they have? I feel the only way that they can
really determine thi3 i3 on an experimental baslB where they would try a run in their plant. If they get Aroclor fumes present in the plant, they would then have to give serious consideration to either modification of their equipment to eliminate the fumes or the elimination of Aroclor from the
formulation.
It is impossible to say whether or not they would
have a problem until they made a trial. I think we can safely assure them, however, that on an experi mental basis fumes of sufficient quantity to be hazardous (in a short period of time) would probably
not be present. If they were present in sufficient quantities, in a short period of time their workers
would walk off the job.
I am sending a copy of this to Bill Hunt in case he has additional comments to make.
W. F. WAYCHOFF
WFW/cas
DSW 147785
STLCOPCB4039395
-- c.--
ATTENTION W. H. HUNT: I am not trying to do your
,
but at this stage of the yame it looked as though the
customer was worrying before they had tried it out In
1* C '-ic
iven set of equipment as well they should. However,
hink the only real answer for them is to make a trial.
WFW
DSW 147786 STLCOPCB4039396