Document QJoqdp4wVzxGEEz8Nobe7vLe7

CLEAN AIR ACT GASOLINE VOLATILITY INSPECTION REPORT Inspection Date Regulatory Program Facility Name Facility Physical Location Facility Contact Report Finalized June 1, 2024 Clean Air Act - Gasoline Standards Sinclair Gas Station 800 West Hampden Ave, Englewood, CO 80110 (b) (6) TAYLOR Digitally signed by TAYLOR WAANDERS WAANDERS 10:01:17 -06'00' Date: 2024.06.01 Technical Team Lead Fuels Enforcement Branch Air Enforcement Division I. FACILITY OVERVIEW AND INSPECTION OBJECTIVES Sinclair Gas Station , hereinafter referred to as Sinclair , is retail station located at 800 West Hampden Ave, Englewood, CO 80110 and sells gasoline and diesel fuel. Sinclair has 8 of pumps available to dispense gasoline. The retail station The U.S. Environmental Protection Agency (EPA) selected Sinclair for inspection because it sells gasoline regulated under Title II of the Clean Air Act (CAA). The purpose of the inspection was to evaluate Sinclair 's compliance with the gasoline standards set forth at 40 C.F.R. Part 1090, Subpart C. II. INSPECTION ACTIVITIES The EPA arrived at Sinclair at 8:20 AM on June 1, 2024 . Inspectors presented their credentials upon arrival and explained the purpose of the inspection. The inspection team received permission to take gasoline samples. The following personnel participated in this inspection: Name Taylor Waanders Griff Brown Cassidy Owen Ryan Diehlmann Title Chemical Engineer Environmental Engineer Chemical Engineer Chemical Engineer Organization U.S. EPA U.S. EPA Eastern Research Group, Inc. Eastern Research Group, Inc. The inspection team collected and screened field samples. The inspection team shared the results of the field screening and left the facility at 9:55 AM. III. OBSERVATIONS Otherwise noted, this section of the report describes what was observed by the inspection team. This report may not capture all operations or activities ongoing at the time of the inspection. This report does not make final determinations on potential areas of concern, and nothing in this report affects the EPA's authorities under federal statutes and regulations to pursue further investigation or action. A. Field Screening Analysis Field Screening Information Field Screening Results Sample ID Pump Number Collectiona Time Sample of Gasoline Grade RVPEb (psi) Ethanolc (vol%) 1 5 8:26 AM Regular 7.37 2 5 8:31 AM Midgrade 7.27 3 5 8:35 AM Premium 7.19 aAt least three gallons of gasoline were flushed from pump before field screening sample was collected. bField screening results were determined using Grabner analyzer (Serial Number 202-205). cField screening results were determined using PetroSpec analyzer (G1309). 10.1 9.4 10.4