I Februory, 1964 | ASI-1131 12334 packaged for forced hot water all-purpose boiler-burner unit all-purpose boiler -'--2 ''srrs.'ils :?\v 'toiler fhaf answers many needs The oil-fired A-3 is a new boiler developed to meet requirements for forced water, gravity and steam sys tems--with provision for domestic hot water on forced water and steam boilers. The packaged A-3-available in 3 sizes for forced water only--is ideal for fast, lowcost installation, especially in new homes. All controls are pre-mounted, pre-wired. The all-purpose A-3--avail able as a boiler-burner unit or boiler only in 5 sizes-- is ideal for forced water, gravity and steam application in new construction, replacement or modernization. Whether packaged or all-purpose, all A-3 boilers bear these big convenience features: factory-assembled cast iron sections, factory-installed combustion chamber, l = B = R approved ratings, wet-base design and front location of all controls and accessories. The A-3 can't be matched for efficiency and versatility! to system ELIMINAIRE is an exclu sive cost-saving feature on packaged A-3 units only. Integrally cast into the front section, the ELIM INATE baffle deflects ris ing air bubbles directly into the expansion tank through a special tapping in the section. No external device is needed to sep arate air and water. air eliminator baffle Cast Iron Section features vertical flue design with finned surface area to extract maximum heat from com bustion gases. Wet base construction eliminates need for special base. Two 5" nipple ports on all-purpose A-3 boiler allow flexibility in loca tion of tankless water heater. i High Capacity Tankless Water Heater is available in four sizes, factory- *i installed in all A-3 boilers. High l=W=H ratings are obtained by actual test of the heater in the boiler. The tankless heater coil is inserted into upper nipple port on hot water installations, lower nipple port on steam installations. . >fvr. Model OH-5 Arcoflame Oil Burner provides efficient firing with an exceptionally clean flame. It's easy to adjust the new EXACTAIRE slide damper for per fect air-oil mixture -- the only adjustment needed! Lightweight, rugged diecast aluminum housing in sures lasting alignment of fan, motor, fuel unit. I I i i - ........... . 12335 oil-fired boilers 1- -all controls (including primary control) are mounted on front for easy service and adjustment. Con trols are factory-mounted and pre-wired on packaged units. Primary control features light-sensing detector for instant response to ignition and shutdown. 2- - it :(optional) has removable panels for ready access to burners and controls. 3_ i- -ii--is engineered to provide top operating efficiency. Sling mount and EXACTAIRE control simplify installation and adjustment. 4-- - -'-allows for adjustment of secondary air whenever it's required. 5_ h:.- large, copper coil tankless type, with l = W=H approved ratings, is inserted into upper 5" nipple port on forced water boiler, lower nipple port on steam boiler. A-3 packaged boiler furnished with upper tankless heater opening only. 6--toiler sections-are designed with vertical flue pas sages and constructed of durable cast iron. Sections are tested at 2Yi times normal operating pressure. 7_cieanout panel-one-piece panel permits cleaning of all flue surfaces from right side without dismantling jacket or disturbing burner, controls and accessories. 8_.3Cket--smartly-styled of sturdy steel in sparkling gray finish with modern radius corners. Jacket is assembled with boiler at factory for packaged models. 9-- combustion chamber--js made of high-temperature stainless steel. It provides even heat distribution to combustion area and is factory-installed. 10-- vet base construction--provides an extra heat-absorb ing bottom surface. Waterways completely surround com bustion area and extend beneath the boiler, making the A-3 ideal for first-floor utility room, as well as basement installation. 12336 A-3 ratings boiler number steam water gross l=B=R output (Btu/hr) net l = B = R l = B = R ratings! burner water l> staam (Btu/hr) steam (sq.ft) capac ity (iph) chimney size height (inches) (feet) water content full (Ea(lons) __ -- -- A-33-SBIT) A-34-SBCD A-35-SB(T) A-36-SB(T) A-37-SBCD A-33-PIT) A-34-PIT) A-35-PIT) crc^a voter sruvj 100,000 75,000 __ 136,000 102,000 -- 173,000 129,800 -- ' . n rs A-33-WB(T) A-34-WB(T) A-35-WB(T) A-36-WB(T) A-37-WBIT) 100,000 136,000 173,000 208,000 244,000 75,000 102,000 129,800 156,000 183,000 313 425 541 650 763 0.95 1.35 1.70 0.95 1.35 1.70 2.00 2.30 8x8 8x8 8x8 15 15 15 8x8 8x8 8x8 8x8 8x12 15 15 15 15 15 25.0 23.8 27.1 25.0 23.8 27.1 30.5 33.8 A-33-S(T) A-34-S(T) A-35-S(T) A-36-S(T) A-37-S(T) A-33-WIT) A-34-WIT) A-35-WCO A-36-W(T) A-37-W(T) 100,000 136,000 173,000 208,000 244,000 75,000 102,000 129,800 156,000 183,000 313 425 541 650 763 0.95 1.35 1.70 2.00 2.30 8x8 8x8 8x8 8x8 8 xl2 15 15 15 15 15 25.0 23.8 27.1 30.5 33.8 The ratings for these boilers represent the net loads that may be connected to the boilers. Allowances have been made for normal piping and pick up loads. Amencan-Standard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements. Nozzle sizes, gph, furnished with A*3 boiler-burner units: A-33, 0.90-60* H; A-34, 1.2S-60* H; A-35, 1.50-60* S; A-36, 1.75-60' S; and A-37. 2.25-60' S. Note: Suffix fetters denote the following: P-packaged unit for forced circulation; B-boiler-bumer unit; T-with tankless heater; S-for steam; W--for water. tankless heater ratings boiler number l=B=R burner capacity heater number* * -- W=H ratings (EPhU (gph) water steam A-33 0.95 222 4 A-34 1.35 230 4 3W 3Vz A-35 1.70 328 4% 4V A-36 2.00 335 5W 4% A-37 2.30 335 5% SVa A Gallons of water per minute heated frpm 40 F to 140*F with 200*F boiler water temperature, e Domestic hot water connection size for all heaters is Vi" l.P.S. optional controls for non-packaged units For forced circulation less heater: No. 4 control set consisting of CB-52S02 thermostat, L40628 Aquastat limit and circulator control, plus a No. R8184A light sensing constant ignition primary control available instead of R8182C combination control. For forced circulation with tankless heater: No. S con trol set consisting of CB-52502 thermostat L8042A Aquastat. limit, reverse and operating circulator relay plus a No. R8184A light-sensing constant ignition primary control available instead of R8182A combina tion control. Add-on No. S-Z control set is available for use with A-3 all-purpose non-packaged boiler-burner units with tankless heater. American-Standard hydronic zone valve packages are available for water units and boilers. See current price book for details and prices. equipment furnished -oner :cr 'orcsn :;rrjia;icn standard equipment Model OH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. CB-52502 thermo stat. Nozzle. Draft regulator. High temperature steel combustion chamber. Pressure and temperature gauge. ASME relief valve. lVt" circulator with piping. Wiring harness. Flush jacket. Drain valve. with tankless heater: Factory-installed built-in tankless heater (as shown in heater rating table above). R8182A combination Aquastat-relay, high limit, low limit and circulator control, light-sensing constant ignition primary control. less heater: R8182C combination Aquastat, limit and circular control, light-sensing constant ignition primary control. Heater opening cover plate. Note: Packaged units are shipped with flush jacket, all elec trical controls (except thermostat), circulator and piping, fac tory installed and wired. OH-5 oil burner shipped separately. Draft regulator, relief valve and thermostat are packed inside boiler crate. optional equipment Jacket extension: if desired, specify on order. Jacket extension, shipped in separate carton, extends 1544" in front to conceal burner and controls. Approximate shipping weight: 35 lbs. Two-stage fuel unit is furnished when specified on order. : -lurtoss ':ci:.er-;'jrnsr '.'nits standard equipment Model DH-5 Arcoflame oil burner with sling mounting and factory installed cad cell, bracket and leads. CB-52502 thermo stat. Nozzle. Draft regulator. High temperature steel combus tion chamber. Pressure and temperature gauge. ASME relief valve with water units: ASME safety valve with steam units. Flush jacket. Drain valve. with tankless heater: Factory installed built-in tankless heater (as shown in heater rating table above). Heater is installed in upper nipple port on water boilers and in lower nipple port on steam boilers, water: R8182A combination Aquastat-relay, high limit, low limit and circulator control, light-sensing constant ig nition primary control. steam: PA404A Pressuretrol, L4006A Aquastat operating con trol and R8184A light-sensing constant ignition primary control, less heater: water: R8182C combination Aquastat limit and circular con trol, light-sensing constant ignition primary control, steam: PA404A Pressuretrol and R8184A light-sensing constant ignition primary control. optional equipment Jacket extension--same as for packaged units. External low water cut-oft for steam boilers. Built-in tankless heaters can be ordered for separate shipment with units less factory-installed tankless heater. Optional con trol sets are available on order. (See current price book.) Two-stage fuel unit available on order. Motors and controls regularly furnished with A-3 packaged and boiler-burner units are for 115 volt 60 cycle current. all-purpose boiler only standard equipment Flush jacket, ASME relief valve with water boilers, ASME safety valve with steam boilers. High temperature steel combustion chamber. Water heater cover plate, and tankless heater, when specified on order. optional equipment Jacket extension. Built-in tankless heaters are available lor separate shipment. 12337 1 dimensions and tappings packaged A-3 boiler O w4< 3% top view oil-fired boilers side view extended jecket section (tins boiler number A-33-P A-34-P A-35-P number and size of tappings (inches) flow return 1-1% 1-1 Vi 1-lVi 1-1^2 1-1% 1-1V2 A 10% nv 14% dimensions (inches) BC L 0 flush extended jacket jacket 8% 6 6 16Vb 31% 8% 7 3% 17% 32% 10% 7 3% 20% 36% assemblage of sections F, CW, B F, C, C, B F, C, C, C, B legend F--front connecting section CW--wide center section C--center section B--back section rrt ' |i .nyii cont rol tap lings-packaged boiler / location size on boiler Gnches) ; control used . v. . A % relief valve R8182A combination Aquastat, relay B % and primary control (for installa tions with tankless heater). R6182C combination Aquastat and C % primary control (for installations without tankless heater). 0 V* pressure and temperature gauge E % auxiliary control tapping forced water crated dimensions packaged boiler number dimensions Gnches) HW L approx. shipping weight (pounds) A-33-P A-34-P A-35-P 48% 25% 27% 48% 25% 27% 48% 25% 30% 735 818 956 Standard 12338 dimensions and tappings all-purpose A-3 boiler opening. Wa| 1 | 'T 18% * r \) r2H mf t --18V4--*| ^--3" flow top view flush jacket extended jacket boiler number A-33 A-34 A-35 A*36 A-37 number end size of tappings (inches) flow return 1-3 1-2% 1-3 1-2% 1-3 1-2% 1-3 1-2% 1-3 1-2% A 10% 11% 14% 16% 21% dimensions (inches) L B c D flush extended jacket jacket 8% 8% 10% 12% 13% 6 7 7 8 9 6 16% 31% 3% 17% 32% 3% 20% 36% 3% 24% 39% 3% 27% 43% assemblage of sections F,CW,B F,C,C,B F,C,C,C,B F,C,C,C,C,B F.C,C,C,C,C,B control tappings -- all purpose boiler location sin on boiler (inches) watsr control used - - steam control usodj water heater (optional) A % relief valve safety valve B % R8182A combination Aquastat, relay and orimarv control ffor installations with tankless water heater)-or optional controls L4006A Aquastat operat ing control (for installa tions with tankless water heater)-or optional controls R8182C combination Aquastat and c % primary control (for installations without tankless water heater)- or optional controls -- D % pressure and temperature gauge steam gauge E % auxiliary control tapping PA404A Pressuretrolor optional controls F i% not used blow off G % not used gauge glass and Tow water cut-off front view all purpose (water) section thru boiler F--front connecting section CW--wide center section C--center section B--tack section Sections for all A-3 boilers shipped factory-assembled. water heater (optional)' outlet- front view all purpose (steam) 6 12339 -A = 3 oil-fired boilers minimum piping recommendations ' c r .--?r Procedure far filling series loop Heetrim System: 1. Close an zone valves except zone to be purged. 2. Open boiler drain valve. 3. Open fill valve. 4. Close purge valve. 5. Vent air from boiler by manually opening relief valve. 6. Open second valve to be purged. Close first zone. After second zone is purged, open third zone valve and close second zone. Repeat for as many zones as in system. (Note: Always have one zone valve open.) 7. When all zones have been purged, close boiler drain cock. 8. When water appears at relief valve, release lever and allow to close. 9. Continue filling until pressure gauge reads approxi mately 12 Ibs./sq. in. Close fill valve. 10. Open purge valve. Note 1: Where multiple circuits are used without zone valves, square heed cocks should be installed for balancing. These square head cocks can be shut off to purge each circuit in turn. Note 2: For a single loop Heatrlm System, no additional vents, cocks, valves, drains, or other accessories are required-with one exception. If tankless heater Is used and Heatnm is above the boiler outlet, a flow check valve must be installed to prevent gravity circulation. *on a single circuit job balancing cocks and zone valves not needed 'Tviry .: = : steam boiler number A-33 A-34 A-35 A-36 A-37 (sinuephpolyi) IV* 1W 2 2 2Vi return (Inches) tv* IVi 2 2 2V4 boiler number A-33 A-34 A-35 A-36 A-37 supply return equalizer (incfiea) (indies) (inches) 1V4 1 1V4 2 1 1V4 2 1 1V4 2Vz 1 1V4 3 m 1V4 A-3 oil-fired boilers are designed and built to comply with the American Society of Mechanical Engineer's Code, and bear their approval symbol. Ratings have been ap proved by the Institute of Boiler and Radiator Manufacturers. The Model DH-S Arcoflame Oil Burner is listed by the Underwriters' Laboratories, Inc. for No. 1 and No. 2 fuel oil; complies with Commercial Standard CS-75; and is approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Common wealth of Massachusetts, and by the Department of State Police, State of Connecticut. (^jjy)AMERicAN-z$>fandard 12340 7 oil-fired boilers control sets No. 1 (steam) & No. 3 (gravity) wiring diagrams -- without tankless heater control set No. 2 (steam) --with tankless heater control set No. 4 (constant circulation) --without tankless heater L40628 control set No. S-Z American-Standard Hydronic Zone Valve Manifold Package (3 zones shown) 110 volt line form No 193-2 (Rev.) ttiemKBtat connections 31-can--Standard PLUMBING AND HEATING DIVISION AMERICAN RADIATOR & STANDARD SANITARY CORPORATION 40 WEST 40TH STREET NEW YORK, N.Y. 10018 12341 Litho